IN-CEILING ENERGY RECOVERY VENTILATORS

ERV-IC 900-ECP
Technical Data

Airflow
Supply Air 900 l/s (nominal)
Exhaust Air 900 l/s (nominal)
Outside Air 100%
Fans Contact your Air Change representative for a psychrometric unit selection

Type EC Plug
Total Fans x1
Nominal Power 2.5kW
Fan Diameter 310 mm Air-to-Air Heat Exchanger
Supply Air

Fan Speed (max.)  3640RPM HEX Type Counterflow Plate


Motor Efficiency Class IE4 HEX Media Sensible-only or Enthalpy
Ingress Protection Class IP54 Electrical & Controls
Speed Control External 0-10V Signal Electrical Input 415V / 3ph / 50 Hz
or Potentiometer Controller Full Load Amps 7.6A
Fans Control Low Level Interface
Type EC Plug Construction
Total Fans x1 Weatherproof No
Nominal Power 2.5kW Casing Galvanised Sheetmetal
Fan Diameter 310mm Insulation 12mm Polyurethane Film Faced Foam
Exhaust Air

Fan Speed (max.) 3640RPM Internal Drain Tray Incl. with Sensible-only HEX option
Motor Efficiency Class IE4 Internal Filters Panel Filters included
Ingress Protection Class IP54 Filter Quantity x2
Speed Control External 0-10V Signal Filter Size (W x H x D) 635 mm x 625 mm x 50mm
or Potentiometer Controller Filtration Grade G4

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.
Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.
ERVIC900TECHAU01.01

Cooke Industries - Phone: +64 9 579 2185 Email: sales@[Link] Web: [Link]
IN-CEILING ENERGY RECOVERY VENTILATORS

ERV-IC 900-ECP
Technical Data

Dimensions

OA / RA Spigot
590
OA / RA Spigot

540

Unit Weight: 300kg


Filter Access

BACK VIEW
BOTTOM VIEW

160
OA / RA Spigot

30
540 30
Fan Access

25mm Drain Connection


(Sensible-only HEX option)
650
Height
Overall
Alternate SA / EA
Spigot 375
Overall Length

PLAN VIEW
Body Length

SIDE VIEW
1590

1400

40

53
1300
Body Width Spigot 500
Alternate SA / EA
1400
Overall Width
Electrical
Panel
so that the SA Spigot is diagonally

SA / EA Spigot
opposite to the OA Spigot, and
Note: Unit must be configured

50
375
the EA Spigot is diagonally
opposite to the RA Spigot.

FRONT VIEW
450
SA / EA Spigot
375

50

53

500
SA / EA Spigot

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.
Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.
ERVIC900TECHAU01.01

Cooke Industries - Phone: +64 9 579 2185 Email: sales@[Link] Web: [Link]
IN-CEILING ENERGY RECOVERY VENTILATORS

ERV-IC 900-ECP
Technical Data

Wiring Diagram

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.
Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.
ERVIC900TECHAU01.01

Cooke Industries - Phone: +64 9 579 2185 Email: sales@[Link] Web: [Link]
IN-CEILING ENERGY RECOVERY VENTILATORS

ERV-IC 900-ECP
Technical Data

Supply / Exhaust Air Fan Curve

2000

1800

1600

1400
External Static Pressure (Pa)

1200

1000

800

600

400

200
Nominal
0
airflow
0 100 200 300 400 500 600 700 800 900 1000
Airflow (l/s)

3640RPM (Max.) 2503RPM (900l/s @ 250Pa external static pressure)

Fan Absorbed Power (900l/s @ 250Pa external static pressure): 793W

Supply / Exhaust Air Fan Acoustics (Sound Power)†

900/s @ 250 Pa External Static Pressure


Inlet
Frequency (Hz) sum 63 125 250 500 1000 2000 4000 8000
A-weighted (dB) 75 39 49 65 70 68 70 65 60
Non A-weighted (dB) 78 65 64 72 73 68 69 64 61
Outlet
Frequency (Hz) sum 63 125 250 500 1000 2000 4000 8000
A-weighted (dB) 83 40 51 69 73 79 78 72 67
Non A-weighted (dB) 84 66 66 77 75 79 77 71 68

Noise data considers supply / exhaust air fans individually, without attenuation by the cabinet.

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.
Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.
ERVIC900TECHAU01.01

Cooke Industries - Phone: +64 9 579 2185 Email: sales@[Link] Web: [Link]