Low Pressure Filters Specifications Guide
Low Pressure Filters Specifications Guide
NF Series
In-Tank / Inline Filters
360 psi • up to 450 gpm (4” piping)
up to 1350 gpm (6” piping) Hydraulic Symbol
A A
B B
1.0Version
1.0 version 2.0Version
2.0 version
Technical Specifications
Mounting Method See drawings
Port Connection
330 / 500 / 750 SAE DN 38 (1 1/2”) Code 61
1310 / 2610 4” SAE DN 102 Flange Code 61
1340 / 2640 (with M16 bolts included) - other
options available
1350 / 2650 SAE DN 51 (2”) Code 61
SAE DN (2 1/2”) Code 61
SAE DN 76 (3”) Code 61
Flow Direction
1.0 version Inlet: Side Outlet: Bottom
1.0 Version 2.0 Version 1350 / 2650
2.0 version Inlet: Side Outlet: Bottom
1350 / 2650 Inlet: Side Outlet: Side
Construction Materials
Features Head, Housing, Lid Aluminum
• N F Filters have an extremely large filtration area and flow capacity Elbows, Manifolds Ductile Iron
of 450 gpm (4” pipe size limitation)
Flow Capacity 4” Headers
• NF Filters can be configured for in-tank or in-line applications
• Vent and drain ports are standard 330 80 gpm (303 lpm)
500 132 gpm (500 lpm)
• Aluminum alloy is water tolerant - anodizing is not required
750 200 gpm (757 lpm)
for high water based fluids (HWBF)
1310, 1340, 1350 343 gpm (1300 lpm)
• Screw-on lid provides easy access to filter element 2610, 2640, 2650, 5240, 7840, 450 gpm (1700 lpm)
for replacement 10440
• Reusable contamination basket prevents re-entry of retained
contaminants into the reservoir during element replacement 6” Headers
(1.0 Version only) 5210..D7/D8 900 gpm (3407 lpm)
• F ilters can be fitted with clogging indicators to monitor the 7810.. D7/D8 1350 gpm (5110 lpm)
contamination level of the element 10410.. D7/D8 1350 gpm (5110 lpm)
• Flange connection bolts included for all SAE-DIN flange ports Housing Pressure Rating
Note: This filter is configured with an …..R…. type (return/low pressure) Max. Allowable Working Pressure* 360 psi (25 bar)
element, so if the filter requires a bypass, the bypass is located in the Fatigue Pressure 360 psi (25 bar)
closed end cap of the cartridge element.
Burst Pressure 1754 psi (121 bar)
Element Collapse Pressure Rating
Applications ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, P/HC, AM 145 psid (10 bar)
V 435 psid (30 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Consult HYDAC for applications below -22˚F (-30˚C)
Fluid Compatibility
Agricultural Gearboxes Industrial Power Compatible with all hydrocarbon based, synthetic, water glycol,
Generation oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
∆P = 29 psid (2 bar) -10% 1.0 - Static
∆P = 72 psid (5 bar) -10% 2.0 - Differential
Bypass Valve Cracking Pressure
Pulp & Paper Shipbuilding Steel / Heavy
Industry ∆P = 14.5 psid (1 bar) +10%
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10%
*Note: All NF…1.0 Filters MAWP reduce to 7 bar (101.5 psi) when using the
following “VMF” and “VR” indicators: B, BM, E, ES, GC, LE, LZ.
Vent port
SW 6
G1/4" 1.47
37.3
Hex
∆P Clogging
indicator
port
G 1/2"
0.440
11.2
Thru
5.70 6.68
4 Places
144.8 169.7
5.63
143
7.00
177.8
Bottom View
Mounting Pattern
11.42
290
0.71
18
Thru NF 1310: [18.50]
470
NF 2610: [36.02]
915
Clearance required for
element removal
4.92
10.24
125 INLET
Vent Port SAE DN 100 260
G 1/2" 4" Flange Lid Top
Filling
Connection 3.06
Port 77.8
G 3/4" 4.33
110
Static Clogging
Indicator Port NF 1310: [23.86]
G 1/2" 606
NF 2610: [41.14]
7.87 1045
200
M16 X 2 X 24 Dp
4 Places
∆P Clogging
indicator port
(not used in 1.0
configuration
M16 X 2 X 23 Dp
G 1/2")
4 Places
5.12
130
9.21
234
OUTLET 11.02 Tank Cutout
SAE DN 280
11.42
4" Flange 3.06 0.71 290
77.8 18 Bolt circle
Bottom View
Mounting Pattern
NF 1340: [18.50]
470
NF 2640: [36.02] 10.24
915 260
Clearance required
for element Lid Top
Vent Port
removal
G 1/2"
7.87
200
NF 1340: [23.31]
592
NF 2640: [40.59]
1031
0.94
M16x2 24
4 Places 3.06
77.8
INLET
5.47 Filling Connection Port
SAE DN 100 139 G 3/4"
4" Flange
∆P Clogging
∆P Clogging Indicator port
Indicator port 5.12
4.92 G 1/2"
130
G 1/2" 125
Dirty Side Drain Port
G 1/2"
2 Places
(180 Degrees opposite)
OUTLET
SAE DN 100 3.06
4" Flange 77.8
0.91
M16x2 23
4 Places
5.12
130
Vent port
G 1/2"
9.84
250
NF1350 :[18.50]
470
NF2650 :[36.02]
915
Clearance required 10.24
for element removal
260
Lid top
26.89
NF 1350: 683
[44.17]
NF 2650: 1122
7.87
200
INLET OUTLET
M
4 Places
7.6
193
B 2.8
∆P Clogging 0.98 C 71
indicator 25 A
port Dirty side drain port ∆P Clogging
G 1/2" G 3/4" indicator
port
Dirty side drain port G 1/2"
G 3/4"
6.69
170
6.54
166
Port Connections
Flange A B øC M
2” SAE-DN 50 77.8 42.9 50 M12 x 1.75 x 19 DP
2 1/2” SAE-DN 65 88.9 50.8 65 M12 x 1.75 x 19 DP
3” SAE-DN 80 106.4 62.9 75 M16 x 2.0 x 24 DP 0.53
Bottom View 13.5 Thru
4” SAE-DN 100 130.2 77.8 100 M16 x 2.0 thru 4 Places
Mounting Pattern
25.66
651.8
9.82 18.98
249.5 482.2
[36.02]
915
Clearance 3.94
required for Vent port 100
element removal 10.24 G 1/2"
Vent port 260.2 2 Places
G 1/2" Lid Top
7.87
200
Static
clogging
indicator 0.75 Inlet
19 SAE DN 100
49.43 port
Thru 4" Flange
1255.5 G 1/2" 8 places Smooth
2 Places Face
SAE DN 100
Blanking
Dirty side port 4" Flange
5.12 G 1/2"
Filling 4 Places
130
Connection +0.12
10.37 - 0
Port
Outlet 3
G 3/4" 3.06
SAE DN 100 263.5+0
2 Places 77.8
4" Flange
Smooth
Face
∆P Clogging 3.94
indicator 100
port 11.81 5.91
G 1/2" 150
4 places 300
11.81
300 4.72
120
0.55
14
Thru
Mounting Pattern
4 Places
Size
Dimensions are [inches] Millimeters 5240
Weight (lbs.) 198.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
For complete dimensions please contact HYDAC to request a certified print.
Vent port
G 1/2"
3 Places
18.98
9.82
482.2
249.5
3.94
100
5.91 11.81
[36.02] 150 300
915
Clearance 34.75
required 882.7
for element
removal
10.24
Vent port 260.2
G 1/2" Lid Top
Inlet
SAE DN 100 7.87
4" Flange 200
49.43 Static Smooth
1255.5 clogging Face
indicator 0.75
port 19
G 1/2"
3 Places Thru
8 Places +0.12
10.37 - 0
Filling 3
263.5 +0 Dirty side
connection drain port
port G 1/2"
G 3/4" 5.12 6 Places
3 places 130
3.06
77.8
3.94
Outlet 100
SAE DN 100 17.72
4" Flange ∆P Clogging
450 indicator
Smooth
Face port
29.53 G 1/2"
6 places
750
11.81 13.70
300 348 4.72
120
0.55
14
Mounting pattern
6 Places
Size 7840
Weight (lbs.) 275.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
Dimensions are [inches] Millimeters
For complete dimensions please contact HYDAC to request a certified print.
49.28
1251. 8
9.84 18.98
250 482. 2
11.81
5.91 3.94
300
150 100
typ
[36.02]
915
Clearance
required
for element 10.24
removal 260. 2
Vent port
G 1/2" Lid top
4 Places
INLET
SAE DN 100 7.87
4" Flange 200
4" SAE DN
Smooth Blanking
Static Face
clogging flanges
indicat or 0.75
port 19
49.43 G 1/2" Thru
4 Places 8 Places +0.12
1255. 5 10.37 - 0
3
Filling 263. 5+0
connect ion
port 5.12
G 3/4" 130
4 places 3.06
77.8
Dirty side port
G 1/2" 3.94
8 places 100
OUTLET ∆P Clogging
SAE DN 100 indicator
4" Flange port
G 1/2"
Smooth
Face 8 places
11.81 11.81
300 300
11.81
300
0.55
14 4.73
Thru 120
8 Places
Mounting Pattern
Size 10440
Weight (lbs.) 397
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
For complete dimensions please contact HYDAC to request a certified print.
11.81 5.91
300 150
29.99 [36.02]
761.8 915
Clearance
10.24 required
260 Manual vent for element
Lid top valves Option removal
G 1/2" ports
2 places
Drain
manifold
Filling connection 61.41 (Option)
G 3/4" 1559.7 15.55
3 places 395
6.25
OUTLET 158.7
6" ANSI CS
12.8 300 lb flange
325 25.84
26.67 656.3
677.4 ∆ P Clogging indicator
port G 1/2"
2 places
M16 X 2
1.5 Threaded
38.1 Typ
11.81 1.5 4
300 38.1 101.6
13.31
338.1
Mounting Pattern
11.81 11.81
300 300
5.91
150
39.88
1012.9
[36.02]
10.24 Manual vent 915
260 valves Option Clearance required
Lid top G 1/2" ports for element removal
3 places
Drain
manifold
Filling connection 61.42 (Option) 2.1 15.55
G 3/4" 1560 53.2 395
3 places
6.25
12.8 158.8 OUTLET
325 6" ANSI CS
300 lb flange
26.67
677.4
∆ P Clogging indicator
port G 1/2"
3 places
M16 X 2
1.5 Threaded
38.1 Typ
4
11.81 11.81 101.6
300 300 1.5
38.1
25.12
638.1
Mounting Pattern
NF 330/500/750 HOUSING
Q in l/min
0 100 200 300 400 500
0.8
10
0.6
8
6 0.4
4
0.2
2
0 0
0 20 40 60 80 100 120 140
Q in gpm
2.0 0.1
0.1 1.0
1.0 0.05
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0500 R XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
0750 R XXX ON 0.116 0.061 0.05 0.029 0.019 0.018
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
Stat-X …R…XSX
Size 3 µm 5 µm 10 µm 20 µm
0330 R XXX XSX 0.204 0.15 0.081 0.056
0500 R XXX XSX 0.143 0.104 0.06 0.038
0750 R XXX XSX 0.061 0.05 0.029 0.018
1300 R XXX XSX 0.04 0.032 0.019 0.012
2600 R XXX XSX 0.02 0.016 0.01 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0500 R XXX ECON2 0.165 0.104 0.071 0.044
0750 R XXX ECON2 0.071 0.049 0.033 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005