0% found this document useful (0 votes)
37 views3 pages

Staircase Design Analysis for Office Building

Uploaded by

Endalk azene
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views3 pages

Staircase Design Analysis for Office Building

Uploaded by

Endalk azene
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

ANALYSIS AND DESIGN OF STAIRCASE

Project OFFICE BUILDING Date Dec-25


Description Stair case Design Design By Robel M
Stair No. Chkd Robel M

DEPTH CALCULATION SATISFAYING DEFELCECTION REQUIRMENTS AS PER ES EN 1992-1-1


(2) Provided that reinforced concrete beams or slabs in buildings are dimensioned so that
they comply with the limits of span to depth ratio given in this clause, their deflections may
be considered as not exceeding the limits set out in 7.4.1 (4) and (5). The limiting
span/depth ratio may be estimated using Expressions (7.16.a) and (7.16.b) and multiplying
this by correction factors to allow for the type of reinforcement used and other variables. No
allowance has been made for any pre-camber in the derivation of these Expressions.

MATERIAL yellow cell input


CONCRTE Fck,mpa 25 ro 0.005
REBAR Fyk,mpa 400 K 1.3 EsEN 1992-1-1 Table 7.4N
Span l (mm) 4980.00 Shorter span simply supp
ASSUMED D,mm 150
Effective d 125 fctm,mpa 2.6
Used rebar % ∅ Area c/c As As,min 211.25 mm2
Bottom 14 153.86 150 1025.733 ρ 0.008206 AS,max 6000 mm2
Top 16 200.96 200 1004.8 ρ' 0.008038
E/qn to be use use eq/n 7.16b
l/d 306.0895
Correction factors
Reinforcement area 0.502791
steel strength 1.25
Span 1
Corrected l/d 192.3737
Actual l/d 39.84 defelction is ok
Required d ,mm 125
Required D ,mm 150

Stair No. 1
0.40 m 3.08 m 1.50 m

Riser = 15 cm
Thread = 30 cm
Waist = 15 cm
θ= 26.57 º
θ Stair width = 1.0 m
Project OFFICE BUILDING Date Dec-25
Description Stair case Design Design By Robel M
Stair No. Chkd Robel M

Loading
Dead load at Steps:

Average slab thickness = 0.168 m

- Own wt. of slab = 1.00 x 25 x 0.168 4.19 KN/m


- 3cm cement screed = 1.00 x 23 x 0.03 0.69 KN/m
- 3cm marble floor finish = 1.00 x 27 x 0.03 0.81 KN/m
5.69 KN/m

- Live load = 3.00 KN/m2 [ES EN 1991-1-1 Table6.2]

ψ2
Design Load = 1.35DL + 1.5LL Quasi DL+f2LL 0.3
= 12.19 KN/m 6.59 Kn/m

Dead load at Landing:


- Own wt. of slab = 1.00 x 25 x 0.15 3.75 KN/m
- 3cm cement screed = 1.00 x 23 x 0.03 0.69 KN/m
- 3cm marble floor finish = 1.00 x 27 x 0.03 0.81 KN/m
5.25 KN/m

- Live load = 3.00 KN/m2 [ES EN 1991-1-1 Table6.2]

Design Load = 1.35DL + 1.5LL


= 11.59 KN/m

Modeling 12.19
11.59 11.59

RZ = RZ =
29.976 29.570
0.40 3.08 1.50

Design actions
- design moment = 36.54 KNm
Project OFFICE BUILDING Date Dec-25
Description Stair case Design Design By Robel M
Stair No. Chkd Robel M

Reinforcement calculation (Eq/n 7.16b)


Top bar cover to rebar center, mm 25
Z bal , 0.82d, mm 102.5
A's(Top reinf.)
A's=(M-0.167fckbd2)/(0.87fyk(d-d') 211.25
Spacing S, mm 951.28994 use S 300
As(Bottom reinf.)
As=((0.167fckbd2)/(0.87fykZbal))+A's 2040.0802
Spacing S, mm 75.418602 use S 150
Maximum S 300
Reinforcement calculation (Eq/n 7.16a)
Moment , M (Knm) 36.539305
Determine K=M/bd2fck 0.0935406 ok

lever arm Z =d/2(1+sqrt (1-3.53k))


less than 0.95d 113.65088

As=M/fyd *z 924.32633 Use


Spacing S 166.45636 40
Maximum S 300
Limiting Crack width
Steel Stressd dS

dS n/mm2 374.2883
Maximum bar size to limt crack width 40 From Table 11 ok
Maximum bar spacing to limt crack width 300 From Table 11 ok

You might also like