GROUP 6
NAME = RAHUL CHOUDHARY (2023UCE1081)
NAME = GAURAV CHOUDHARY(2023UCE1083)
NAME = VIVEK SHARMA (2023UCE1085)
ASSIGNMENT-10
Q-1 A steel column ISHB 250 @ 537 N/m supports a factored load of 1000 kN.
Design a base slab for the column to connect it on M20 concrete pedestal.
Draw the connection details
Solution fck= 20 N/mm
2
Factored Load Pu= 1000 KN
Size of Base plate:
2
Bearing strength of concrete= 9 N/mm
2
Area of base plate required = 111111.1 mm
SQRT of Area= 333.3333 mm
Select base plate size= 340X340 mm
2
Thickness of Base Plate = 8.650519 N/mm
Projection are= 45 mm
ts= 11.61392 mm
Thickness of flange of the column = 9.7 mm
Provide 12 mm thick plate
Connections:
Use 4 bolts of 20 mm diameter ,300mm long as anchor bolts.
weld= 1447.4 mm
2
Strength of weld = 189.3709 N/mm
Let s be the size of weld .then effective area of weld =[Link] Le effective length
The design condition is
0.7sLe*189.37= 1000*10^3
sLe= 7543..8
Using 6 mm weld ,Le required = 1257 mm
Effective length: 1303.4 mm > 1257
Hence , 6mm weld is adequate.
Q-2 Design a gusseted base to carry an axial factored load of 3000 kN. The
column ISHB 450 @ 855 N/m with two 250 x 22 mm cover plates on either
side. The effective height of the column is 5 m. The column is to rest on M20
concrete pedestal.
Solution ISHB 450 @ 855 N/m
Factored Load = 3000 KN
Cover plate = width= 250 mm depth= 22 mm
Height of column = 5m
2
fck= 20 N/mm
2
Area of base plate required= 333333.3 mm
Selecting ISA150115,15 mm angle and16 mm thick gusset plate
Minimum width required = 756 mm
Let width= 800 mm
Length of base plate= 416.6667 mm
Let length be 450 mm
Thus provide 800 X 450 mm plate
2
Intensity of pressure under base plate = 8.333333 N/mm
Assuming load transfer is at middle of (cover plate +gusset plate+vertical leg of angle),
M= -24583.3 N-mm
2
Bending Strength fy/gmo= 227.2727 N/mm
Equating moment of resistance to bending moment ,
1.2*Ze*fy/gmo= M
1.2*1/6*1*t2*227.27= 24583.33
t= 23.25596 mm
Use 25 mm thick plate.
The base plate selected is 800 X 450 X 25 mm
DESIGN LOAD= 1500 KN
Load on each splice= 750 KN
Using 20 mm shop bolts,
Strength of bolt in single shear= 45272.43 N
Bolt value 45272.43 N
No of bolts required= 16.56637
Provide 20 bolts connecting column to gusset plates.
Use another 8 bolts to connect clear angle to gusset plate.
6 anchor bolts of 20 mm diameter and 300 mm long on either side are used to fix column toconcrete base.