API RP 8B Addendum 1 Updates
API RP 8B Addendum 1 Updates
Addendum 1
— measurable wear limits (wear limits for square shoulder elevator bores for casing and tubing
are listed in Tables A.1 and A.2 in Annex A);
The capacity of casing or tubing connections to support a specific load should be determined
with the assumption that the elevator bore is approaching the value listed in Table A.1 or Table
A.2.
Annex A, Section A.2: The section’s sole paragraph shall be replaced as follows:
Square shoulder elevators such as single joint, center-latch, side-door, and similar lift devices
on which the load face is perpendicular to the centerline of the tubular shall be subject to the
wear limits of Table A.1 or Table A.2. Elevators for which the bore measurements exceed Table
A.1 or Table A.2 limits (as applicable) shall either be remanufactured or scrapped.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Recommended Practice for
Procedures for Inspections,
Maintenance, Repair, and
Remanufacture of Hoisting Equipment
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Special Notes
API publications necessarily address problems of a general nature. With respect to particular circumstances, local,
state, and federal laws and regulations should be reviewed.
Neither API nor any of API's employees, subcontractors, consultants, committees, or other assignees make any
warranty or representation, either express or implied, with respect to the accuracy, completeness, or usefulness of the
information contained herein, or assume any liability or responsibility for any use, or the results of such use, of any
information or process disclosed in this publication. Neither API nor any of API's employees, subcontractors,
consultants, or other assignees represent that use of this publication would not infringe upon privately owned rights.
API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure the
accuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, or
guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or
damage resulting from its use or for the violation of any authorities having jurisdiction with which this publication may
conflict.
API publications are published to facilitate the broad availability of proven, sound engineering and operating
practices. These publications are not intended to obviate the need for applying sound engineering judgment
regarding when and where these publications should be utilized. The formulation and publication of API publications
is not intended in any way to inhibit anyone from using any other practices.
Any manufacturer marking equipment or materials in conformance with the marking requirements of an API standard
is solely responsible for complying with all the applicable requirements of that standard. API does not represent,
warrant, or guarantee that such products do in fact conform to the applicable API standard.
Users of this Recommended Practice should not rely exclusively on the information contained in this document.
Sound business, scientific, engineering, and safety judgment should be used in employing the information contained
herein.
All rights reserved. No part of this work may be reproduced, translated, stored in a retrieval system, or transmitted by any means,
electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Contact the
Publisher, API Publishing Services, 200 Massachusetts Avenue, NW, Suite 1100, Washington, DC 20001.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Foreword
Nothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for the
manufacture, sale, or use of any method, apparatus, or product covered by letters patent. Neither should anything
contained in the publication be construed as insuring anyone against liability for infringement of letters patent.
Shall: As used in a standard, “shall” denotes a minimum requirement in order to conform to the specification.
Should: As used in a standard, “should” denotes a recommendation or that which is advised but not required in order
to conform to the specification.
This document was produced under API standardization procedures that ensure appropriate notification and
participation in the developmental process and is designated as an API standard. Questions concerning the
interpretation of the content of this publication or comments and questions concerning the procedures under which
this publication was developed should be directed in writing to the Director of Standards, American Petroleum
Institute, 200 Massachusetts Avenue, NW, Suite 1100, Washington, DC 20001. Requests for permission to reproduce
or translate all or any part of the material published herein should also be addressed to the director.
Generally, API standards are reviewed and revised, reaffirmed, or withdrawn at least every five years. A one-time
extension of up to two years may be added to this review cycle. Status of the publication can be ascertained from the
API Standards Department, telephone (202) 682-8000. A catalog of API publications and materials is published
annually by API, 200 Massachusetts Avenue, NW, Suite 1100, Washington, DC 20001.
Suggested revisions are invited and should be submitted to the Standards Department, API, 200 Massachusetts
Avenue, NW, Suite 1100, Washington, DC 20001, standards@[Link].
iii
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Contents
Page
1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Normative References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 Terms, Definitions, and Abbreviated Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1 Terms and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2 Abbreviated Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 General Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.1 Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.2 Personnel Qualification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5 Inspection and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.3 Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.2 Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.3 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7 Remanufacture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.1 Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.2 Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8 Load Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.2 Performance Load Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.3 Proof Load Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9 Documentation and Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9.2 User/Owner Equipment File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9.3 Activity Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Annex A (normative) Wear Limits for Square Shoulder Elevator Bores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Annex B (informative) Top Drive/Power Swivel Misalignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Tables
1 Periodic Inspection and Maintenance—Categories and Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
A.1 Wear Limits for Square Shoulder Elevator Bores for Non-upset Casing and Tubing. . . . . . . . . . . . . . . . 13
A.2 Wear Limits for Square Shoulder Elevator Bores for Upset Casing and Tubing. . . . . . . . . . . . . . . . . . . . 14
v
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Recommended Practice for Procedures for Inspections, Maintenance, Repair, and
Remanufacture of Hoisting Equipment
1 Scope
This document provides guidelines and establishes requirements for inspection, maintenance, repair, and
remanufacture of items of hoisting equipment manufactured according to API 8A, API 8C, or ISO 13535 used in
drilling and production operations, in order to maintain the serviceability of this equipment.
— block-to-hook adapters;
— drilling hooks;
— elevator links;
— sucker-rod elevators;
— rotary swivels;
— power swivels;
— power subs;
— top drives;
1
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
2 API RECOMMENDED PRACTICE 8B
2 Normative References
The following referenced document is indispensable for the application of this document. For dated references, only
the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
3.1.1
critical area
Highly stressed region of a primary-load-carrying component as defined by the manufacturer.
3.1.2
expendable parts
Parts normally used up or consumed in service.
EXAMPLE Seals, gaskets, filters, packing, V-belts, covers, guards, breathers, drains, and miscellaneous hardware and
fasteners.
3.1.3
inspection
Comparison of equipment conformity to predetermined standards, followed by a determination of action required.
3.1.4
load test
Test wherein a load is applied under controlled and monitored conditions to verify the serviceability of equipment.
3.1.5
maintenance
Actions including inspection, adjustments, cleaning, lubrication, testing, and replacement of expendable parts, as
necessary to maintain the serviceability of the equipment.
3.1.6
manufacturer
Individual or company that makes or processes equipment or material covered by this document.
3.1.7
owner
Individual, legal entity, or organization holding legal title to the equipment.
3.1.8
primary load
Axial load to which the equipment is subjected in operation.
1 International Organization for Standardization, 1, ch. de la Voie-Creuse, Case postale 56, CH-1211, Geneva 20, Switzerland,
[Link].
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTIONS, MAINTENANCE, REPAIR, AND REMANUFACTURE OF HOISTING EQUIPMENT 3
3.1.9
primary-load-carrying component
Component of the equipment through which the primary load is carried.
3.1.10
remanufacture
Action performed on equipment that involves a special process or re-machining.
3.1.11
repair
Action performed on equipment that involves replacement of parts, other than expendable parts, but excludes
remanufacture.
3.1.12
serviceability
Condition of a piece of equipment at any point in time that affects the ability of the equipment to perform its function(s)
as intended.
3.1.13
special process
Operation that can change or affect the mechanical properties, including toughness, of the materials used in
equipment.
3.1.14
testing
Action carried out on a piece of equipment to ensure that it can perform a required function.
3.1.15
user
Individual or company that uses equipment or material, or implements standards.
RT radiographic testing
UT ultrasonic testing
4 General Principles
4.1 Procedures
4.1.1 General
Users/owners of hoisting equipment shall establish written procedures for inspection, maintenance, repair, and
remanufacture of each item of equipment.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
4 API RECOMMENDED PRACTICE 8B
The user/owner and manufacturer should jointly develop and update inspection, maintenance, repair, and
remanufacture procedures consistent with equipment application, loading, work environment, usage, and operational
conditions.
These factors may change as a result of new technology, product improvements, or fundamental changes in service
conditions.
If the manufacturer of the equipment no longer exists or is unable for any reason to provide suitable
recommendations, the user/owner shall develop inspection, maintenance, repair, and remanufacture procedures
consistent with widely-accepted industry practices.
NDT, maintenance, and dismantling equipment shall be properly selected and adapted to the parts to be inspected
and maintained.
[Link] Qualification
Inspectors shall be aware of the type of equipment to be evaluated and the NDT methods to apply.
The users/owners shall verify that the NDT inspector has the following information:
— rejection criteria.
In addition, the users/owners may provide the history of grinding or remanufacture, if available.
In the absence of critical area drawings, all areas of primary-load-carrying components shall be considered critical.
These data shall be used by the inspector to adapt the inspection procedure.
[Link] Certification
The NDT inspector shall be certified according to ISO 9712 or by other recognized NDT certification programs or
standards.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTIONS, MAINTENANCE, REPAIR, AND REMANUFACTURE OF HOISTING EQUIPMENT 5
Inspection and maintenance are closely linked. Inspection and maintenance actions may be initiated based on, but
not limited to, one or more of the following criteria:
— measurable wear limits (wear limits for square shoulder elevator bores for casing and tubing are listed in Tables
A.1 and A.2 in Annex A);
— non-performance of equipment;
— environment;
— experience (history);
— regulatory requirements.
Operators shall review safety considerations applicable to the site where the maintenance activity is performed.
5.2 Maintenance
5.2.1 General
Maintenance of equipment consists of actions such as adjustments, cleaning, lubrication, and replacement of
expendable parts. The complexity of these activities and the safety risks involved shall be considered in the
assignment of appropriate resources such as facilities, equipment and qualified personnel.
5.2.2 Procedures
In addition to the procedures developed in accordance with 4.1, the manufacturer should define any special tools,
materials, measuring and inspection equipment, and personnel qualifications necessary to perform the maintenance.
The manufacturer should also specify those procedures that should be performed solely by the manufacturer, either
within the manufacturer's facility or within another approved facility.
5.3 Inspection
5.3.1 General
The existence of cracks can indicate severe deterioration and impending failure. Their detection, identification and
evaluation require accurate inspection methods.
Prompt attention is then required either to remove the equipment from service immediately or to provide appropriate
service and/or repair.
Caution shall be exercised to take into account the increased susceptibility to brittle fracture of many steels when
operating at low temperatures.
If any manufacturing defects are discovered, they should be reported to the manufacturer or supplier.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
6 API RECOMMENDED PRACTICE 8B
[Link] General
The objective of these inspections is to detect service defects, possible hidden manufacturing defects, and potential
dropped objects.
[Link] Category I
This category involves observing the equipment during operation for indications of inadequate performance.
When in use, equipment shall be visually inspected on a daily basis for cracks, loose fits or connections, elongation of
parts, and other signs of wear, corrosion, or overloading. Any equipment found to show cracks, excessive wear, etc.,
shall be removed from service for further examination.
The daily inspection shall include visual inspection for potential dropped objects and retention devices or features that
can be damaged, in need of adjustment, or missing. Any potential dropped objects or damaged/missing retention
devices shall be immediately corrected.
The equipment shall be visually inspected by a person knowledgeable in that equipment and its function.
[Link] Category II
This is Category I inspection plus further inspection for corrosion, deformation, loose or missing components,
deterioration, proper lubrication, visible external cracks, and adjustment.
This is Category II inspection plus further inspection, which should include NDT of critical areas and may involve
some disassembly to access specific components and to identify wear that exceeds the manufacturer’s allowable
tolerances.
[Link] Category IV
This is Category III inspection plus further inspection for which the equipment is disassembled to the extent
necessary to conduct NDT of all primary-load-carrying components as defined by manufacturer.
— disassembled in a suitably-equipped facility to the extent necessary to permit full inspection of all
primary-load-carrying components and other components that are critical to the equipment;
Prior to Category III and Category IV inspections, all foreign material such as dirt, paint, grease, oil, scale, etc. shall
be removed from the concerned parts by a suitable method (e.g. paint-stripping, steam-cleaning, grit-blasting).
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTIONS, MAINTENANCE, REPAIR, AND REMANUFACTURE OF HOISTING EQUIPMENT 7
5.3.3 Frequency
The user/owner of the equipment should develop schedules of inspection based on experience, the manufacturer's
recommendations, and one or more of the following factors:
— environment;
— load cycles;
— regulatory requirements;
— operating time;
— testing;
— repairs;
— remanufacture.
As an alternative, the user/owner may use Table 1 guidelines. Long-term planning shall be adjusted in order not to
interfere unnecessarily with the running operations.
A complete, on-job, shut-down inspection equivalent to the periodical Category III or Category IV (for the concerned
equipment) should be made before (if anticipated) and after critical jobs (e.g. running heavy casing strings, jarring,
pulling on stuck pipes, and/or operating at extreme low temperatures).
[Link] Unless specific and more stringent recommendations apply, welds of primary-load-carrying components
shall be inspected as follows:
b) after welding, but no sooner than 24 h after the part has reached ambient temperature;
c) in service, after a period of time to be specified in the user/owner/manufacturer's procedures except (unless
otherwise recommended by the manufacturer) for non-accessible inner parts remanufactured under the full
guarantee of the manufacturer.
[Link] The same NDT methods and procedures that detected the initial defects shall be used after remanufacture.
In the event of remanufacture of primary-load-carrying components by welding, at least two of the most appropriate of
the following methods shall apply with regard to [Link] (b).
a) MT, for ferromagnetic materials, or PT, for non-ferromagnetic materials, to detect possible surface defects.
b) UT to detect possible defects below the surface. RT may be used as an alternative to UT if shown to be at least as
effective as UT on the same configuration.
c) Proof load test in accordance with 8.3, followed by surface NDT of the tested component(s).
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
8 API RECOMMENDED PRACTICE 8B
Frequency
Inspection Category
NOTE The above recommended frequencies apply for equipment in use during the specified period.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTIONS, MAINTENANCE, REPAIR, AND REMANUFACTURE OF HOISTING EQUIPMENT 9
Other NDT techniques applied to hoisting equipment shall be submitted for the specific approval of both user/owner
and manufacturer.
Acceptance criteria shall be established based on experience and manufacturer’s recommendations. Worn
equipment that does not meet the acceptance criteria shall not be accepted for operation.
Surface indications identified by NDT may be allowable or non-allowable depending on their size, shape, and
location, as defined by the manufacturer.
Allowable surface indications are surface indications of such a size, shape, and location that they need not be
removed.
Inspection and maintenance (lubrication) of wire rope used in hoisting shall be carried out on a regular basis. API RP
9B [1] may be consulted for further information on inspection and maintenance of wire rope.
Wear limits for square shoulder elevator bores for casing and tubing shall be as specified in Annex A.
5.3.8 Inspection and Maintenance for Top Drive/Power Swivel Misalignment with the Wellbore
Inspection and maintenance for top drive/power swivel misalignment with the wellbore should be carried out as noted
in Annex B.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
10 API RECOMMENDED PRACTICE 8B
6 Repair
6.1 Procedures
Manufacturers should provide adequate information to allow the equipment user/owner to identify the nature of
repairs that may be required. Repairs shall be performed using methods or procedures established in accordance
with 4.1.
6.2 Bearings
Anti-friction bearings play an important part in the serviceability of equipment. The most likely causes of the need for
bearing replacement are very loose or bent cages (rolling element retainers), corrosion, abrasion, inadequate (or
improper) lubrication and spalling due to fatigue. Excessive clearance may indicate improper adjustment or assembly
and should be corrected. Repair of anti-friction bearings should not be attempted by field or shop personnel. The
equipment manufacturer should be consulted in the event of unexplained or repeated bearing failure.
All replacement primary-load-carrying components shall meet or exceed the original manufacturer’s criteria and the
following requirements:
a) the primary-load-carrying components shall be subject to the same minimum requirements and standards as the
original equipment components;
b) the documentation and traceability requirements shall be the same as for the original equipment components.
7 Remanufacture
7.1 Procedures
Remanufacture of equipment shall be performed using methods and procedures developed in accordance with 4.1.
The material used for the remanufacture shall be qualified to the manufacturer's requirements for mechanical
properties, ductility and toughness. The equipment rating resulting from remanufacture should be in accordance with
the equipment manufacturer’s recommendations. Equipment that cannot be remanufactured shall be destroyed.
If welding is necessary, it shall be performed in accordance with a written procedure that has been qualified in
accordance with a recognized standard.
7.2 Verification
8 Load Testing
8.1 General
A performance load test may be used to verify the function of the equipment and/or its ability to perform under specific
conditions or in conjunction with other equipment or materials (e.g. it may be used to determine the effects of gripping
a specific pipe with a given elevator). A performance test may consist of any number of cycles (as needed) of loads
up to, but not exceeding, the rated load of the equipment under test.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTIONS, MAINTENANCE, REPAIR, AND REMANUFACTURE OF HOISTING EQUIPMENT 11
A proof load test is performed by applying a load equal to 1.5 times the rated load of the equipment for a period of not
less than 5 min. Proof load tests should not consist of more than one cycle and shall not be used in lieu of
performance load tests. Hoisting equipment should be proof load tested only once following manufacture or
remanufacture, since loads above the rated load may cause cumulative (fatigue) damage. A proof load test shall be
followed by surface NDT. Materials that are prone to delayed cracking should be subjected to surface NDT no earlier
than 24 h after proof load testing.
The user/owner shall maintain an equipment file containing pertinent information regarding the equipment. The
equipment file should include the following:
9.2.1 General
The user/owner shall build, for each item of equipment, equipment file which includes the following information, where
available:
a) equipment description, type and style, serial number, PSL, specifications, manufacturer;
b) nominal capacities;
c) list of components and assembly drawings, highlighting the steel grades, PSL, and minimum service temperature
of critical components. Critical areas shall be clearly defined;
e) repairable defects with their (maximal) dimensions and location (as applicable);
f) activity records;
9.2.2 Identification/traceability
Unit serial number or identification marking provided by the manufacturer should be maintained on the equipment.
Identification marking shall be provided by the user/owner for unidentified equipment. Serial numbers or identification
marking shall be recorded in the equipment file.
9.2.3 History
Changes in equipment status that could affect equipment safety, serviceability, or maintenance should be recorded in
the equipment file.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
12 API RECOMMENDED PRACTICE 8B
Records of Category III and Category IV inspections shall be entered in the equipment file as well as any load test
data related to or indicating the load-carrying capacity of the equipment.
Entries describing repair, remanufacture and testing activities shall be included in the user/owner equipment file.
e) the date and the name of the responsible person(s) involved in the inspection, maintenance, repair, or
remanufacture.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Annex A
(normative)
Wear Limits for Square Shoulder Elevator Bores
A.1 Evaluation of Casing or Tubing Coupling (or Load Shoulder)
The ability of the casing or tubing coupling (or connection load shoulder) to support the required load is affected by
wear of the elevator bore, which reduces the area of contact between the coupling (or connection load shoulder) and
the elevator load shoulder. The capacity of casing or tubing connections to support a specific load should be
determined with the assumption that the elevator bore is approaching the value listed in Table A.1 or Table A.2. The
load capacity of lift nubbins (or other devices providing a load face perpendicular to the centerline of the tubular),
intended to support the tubular load via contact with the square shoulder load face of elevators bored for a nominal
tubular diameter equal to the tubing or casing upset, shall be evaluated with the same assumed elevator bore and
wear.
Table A.1—Wear Limits for Square Shoulder Elevator Bores for Non-upset Casing and Tubing
Nominal Casing or Tubing Size Maximum Allowable (Worn) Load Shoulder Bore
D DMA
1.001 (D 25.4) + 3.43 mm a
D < 41/2 in.
1.001 D + 0.135 in. b
1.0175 (D 25.4) + 2.03 mm a
41/2 in. ≤ D < 127/8 in.
1.0175 D + 0.080 in. b
1.0175 (D 25.4) + 1.40 mm a
127/8 in. ≤ D ≤ 20 in.
1.0175 D + 0.055 in. b
1.0125 (D 25.4) + 3.96 mm a
20 in. < D < 42 in.
1.0125 D + 0.156 in. b
1.010 (D 25.4) + 7.62 mm a
42 in. ≤ D
1.010 D + 0.300 in. b
Localized wear allowances
When the load shoulder bore diameter is measured, if localized portions of the bore are found to measure larger than
DMA (computed above), the bore need not be rejected if all of the following conditions are met:
a) The depth of wear, grinding, or other damage in localized portion(s) of the bore shall not exceed 3.2 mm (1/8 in.);
b) The surface of a localized wear, grinding, or other damage, shall be blended back to the adjacent bore surfaces with a
transition not less than 3 to 1 (length to depth);
c) After blending, the total length (measured around the bore surface) of all such areas of localized wear, grinding, etc.,
including the transitions to the bore surface, shall not exceed (the nominal diameter x 0.25) in length.
a The computed value of DMA is expressed in SI units of millimeters.
b The computed value of DMA is expressed in USC units of inches.
13
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
14 API RECOMMENDED PRACTICE 8B
Table A.2—Wear Limits for Square Shoulder Elevator Bores for Upset Casing and Tubing
Maximum Allowable (Worn) Load Shoulder Bore, Maximum Allowable (Worn) Load Shoulder Bore,
DU DMA
DU < 114 mm 1.0010 DU + 3.81 mma
(DU < 4 1/2 in.) (1.0010 DU + 0.150 in.)b
114 mm ≤ DU < 327 mm 1.0175 DU + 2.03 mma
(4 1/2 in ≤ DU < 12 7/8 in.) (1.0175 DU + 0.080 in.)b
327 mm ≤ DU ≤ 508 mm 1.0175 DU + 1.40 mma
(12 7/8 in ≤ DU ≤ 20 in.) (1.0175 DU + 0.055 in.)b
508 mm < DU < 1067 mm 1.0125 DU + 3.96 mma
(20 in < DU < 42 in.) (1.0125 DU + 0.156 in.)b
1067 mm ≤ DU 1.0100 DU + 7.62 mma
(42 in ≤ DU) (1.0100 DU + 0.300 in.)b
Localized wear allowances:
When the load shoulder bore diameter is measured, if localized portions of the bore are found to measure larger than DMA
(computed above), the bore need not be rejected if all of the following conditions are met:
a) The depth of wear, grinding, or other damage in localized portion(s) of the bore shall not exceed 3.2 mm (1/8 in.);
b) The surface of a localized wear, grinding, or other damage shall be blended back to the adjacent surfaces with a
transition not less than 3 to 1 (length to depth);
c) After blending, the total length (measured around the bore surface) of all such areas of localized wear, grinding, etc.,
including the transitions to the bore surface, shall not exceed (the nominal diameter x 0.25) in length.
a The computed value of DMA is expressed in SI units of millimeters.
b The computed value of DMA is expressed in USC units of inches.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Annex B
(informative)
Top Drive/Power Swivel Misalignment
B.1 Top Drive/power Swivel Misalignment with the Wellbore
The top drive/power swivel main shaft assembly is subjected to the highest tensile and torsional loads. As wells are
drilled to greater depths and higher deviation, the combination of tensile and torsional loads may reach a level that
represents a high percentage of the strength of the material. When this occurs, only a small amount of cyclic loading
is required to drastically reduce the number of cycles before fatigue failure occurs. Further, when a top drive/power
swivel is misaligned with the drill-string while drilling in these conditions, the amplitude of the resulting bending
moment acting on the main drive shaft assembly components can create high reversing stresses that will result in
premature fatigue failure of top drive/power swivel components. This section identifies some of the major causes of
misalignment and their solutions.
— swivel stem;
— saver sub.
Misalignment between the main shaft assembly and the wellbore can cause cyclic loading stresses to increase to
much higher levels but this can be significantly reduced with proper alignment. Some of the major causes of
misalignment are provided in the following:
a) the vertical axis of the derrick or mast is misaligned with the gravitational axis of the drill-string;
b) the plane of the traveling equipment guide rails (if fitted) is misaligned with the derrick and/or the drill-string;
c) the plane of the guide dolly structure is misaligned with the plane of the guide rails, and/or vertical axis of the
derrick;
d) the guide dolly structure has been damaged, causing misalignment between it and the guide rails;
15
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
16 API RECOMMENDED PRACTICE 8B
e) the axis of the top drive/power swivel main shaft is misaligned with the plane of the guide dolly structure;
f) there are more lines strung onto the sheaves on one side of the traveling block than the other, causing the
traveling block to tilt when under load;
g) for top drives/power swivels used with traveling equipment that can be retracted or extended away from rotary
center, a malfunction in the retraction system that prevents the traveling equipment from returning properly to
rotary center will cause misalignment between the top drive/power swivel and the drill-string while drilling;
h) riser/conductor barrel may not be parallel and concentric with the mast/guide track/top drive main shaft.
NOTE More than one of these conditions can exist at the same time, which can make cause identification difficult.
Maximum misalignment tolerance recommendations should be provided by the top drive/power swivel equipment
manufacturer as each manufacturer utilizes different types of guide systems that each are more or less tolerant to
guide system alignment.
The initial signs of misalignment are often fatigue cracks that occur at greater frequencies in the root of the last-
engaged threads of any box or pin connection in the main shaft assembly. Box connections are generally more
susceptible to cyclic bending fatigue failure than pin connections. Therefore, stress relief features should be
machined into top drive/power swivel connections wherever possible.
NOTE It may not be possible to employ these features on all connections such as those on IBOP valves and the lower swivel
stem box connections.
The thread root of top drive/power swivel main shaft connections should also be cold-worked after all machining to
increase fatigue life. In extreme cases, it may be necessary to employ the use of connections that feature a larger
thread root radius to extend fatigue life.
Regardless of what connections are used or whatever stress-relief features are employed, visual and non-destructive
examination (NDE) should be carried out to the connections of the top drive/power swivel main shaft assembly on a
regular basis as recommended in API 8B and API 7-2, even though the size of the connections used in the main shaft
assembly are much larger than those typically used for the drill-string that is connected to it.
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Bibliography
[1] API RP 9B, Application, Care, and Use of Wire Rope for Oil Field Service.
[2] API RP 4G, Operation, Inspection, Maintenance, and Repair of Drilling and Well Servicing Structures
[3] ISO 13535, Petroleum and natural gas industries—Drilling and production equipment—Hoisting equipment
[4] API Spec 7-2, Specification for Threading and Gauging of Rotary Shouldered Thread Connections
17
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]
Product No. G08B08
Accessed by account: ENI | Date: Mon May 6 [Link] 2019 | IP address: [Link]