Rinnai Eco RB Gas Boiler User Manual
Rinnai Eco RB Gas Boiler User Manual
User Manual
Rinnai Eco RB 16/17 - 25/28 - 30/36
User Rights
A user has the right to receive assistance from the authorized technical service during the warranty period from the date of purchase.
However, the customer will have to pay for Technical Service due to product malfunction caused by customer negligence.
or due to force majeure.
In the occurrence of the following events during the warranty period, the customer will be responsible for the cost of a repair service:
1. A A malfunction due to the insertion of foreign substances (water, beverage, coffee, toys, and others).
2. A A malfunction or damage to the product due to an electric shock or fall of the product that occurs during its use
or installation.
3. A Damage to the appearance or deformation of the product due to organic solvents that include benzene.
4. A A malfunction or damage to the product due to the use of unauthorized parts and/or consumables.
5. A A malfunction of the product resulting from non-compliance with installation standards.
6. A A malfunction of the product due to the use of inappropriate gas type, gas pressure, and/or electrical tension.
7.A The loss and/or damage of parts due to the arbitrary disassembly of the product by the user.
8. A A malfunction or damage to the product due to repair or remodeling of the product by a service technician.
not rated.
9.A A malfunction or damage to the product resulting from force majeure events.
10. A A malfunction or damage to the product resulting from non-compliance with safety information.
Table of Contents
Safety Information 4
Componentes 8
Operation Heating 10
Hot Water 11
Cleaning and Maintenance 12
Solution to Basic Problems 13
Trial and Confirmation Operation 15
Technical Specifications 16
Indicates a situation of imminent danger that, if not avoided, causes serious injuries.
Indicate a potentially dangerous situation that, if not avoided, could cause serious injuries.
Indicate a potentially dangerous situation that, if not avoided, could result in minor injuries.
or moderate and/or material damages.
Warns of a fire danger. Keep the area clean and free of flammable materials.
Danger
If there is a smell of gas,
Try NOT to turn on any switch appliances.
electric, do not connect any power cable
electric, since there is a possible risk of explosion and
Proceed with the following instructions:
In this case, do not use a cellphone nearby; it is recommended to use a phone that is located away from the gas source.
Si; detecta terremotos, incendios, Vapor a Gas, ruido u olor anormal, apague inmediatamente
the food and close the gas shut-off valve, once this is done; quickly open the doors and windows of your home.
Warning
Check that the gas in use matches the gas indicated on the product plate.
If not, there could be incomplete combustion of the gas, resulting in poisoning.
for carbon monoxide or product failure.
- An inappropriate adjustment, alteration, service, or maintenance could significantly affect the safety of the product. Please contact
contact the authorized technical service or consult the manual if you detect any unusual condition.
If there are combustion leaks from the gas vent pipe that is
connected to the boiler, these could cause carbon monoxide poisoning.
carbon.
Also, do not try to extend the power cord that comes by default with the boiler.
The power outlet must be grounded and must have a voltage of 220V / 50Hz.
The extension of a power cable with an extension cord
multiple outlets for others could cause an electric shock or a fire.
Inadequate voltage, frequency, and/or nominal current could result in a discharge.
electrical, fire, or product malfunction.
Use the boiler only for heating or for heating domestic water.
The use of the boiler for inappropriate or improper purposes could lead to a fire or malfunction in the boiler.
Do not drink water collected inside the unit nor use it for cooking. It may be contaminated with bacteria and/or rust.
Do not use heating devices under the thermostat.
Not reading the internal temperature could lead to a malfunction of the boiler.
Make sure that each valve in the rooms is open and that the air is
correctly eliminate
When air is not properly removed from the heating pipes, it could
interrupt the centralized heating, as it prevents the heating water from circulating.
In addition, there could be a noise of water circulating in the boiler and the collectors.
Regarding the installation, it is recommended to install the product in a location where the temperature does not drop close to a
freezing temperature. (-0º)
If the water pipes are frozen, there would be no hot water supply. Use a hair dryer or a heater.
portable electric for defrosting, the cold water pipes and hot water pipes; If this emergency measure does not
It works, contact the authorized service center.
Exhaust Duct
13
2
Main Controller
Pressure Indicator (Manometer)
4
bar
1 2
ba r
Gas Duct
Heating Filter
Accessories
Check to ensure that all the accessories listed below come with the boiler.
3 1
To achieve the proper flow of hot water at the predetermined temperature, open the hot water tap completely.
The boiler does not work unless hot water is used, even if the hot water supply mode is on.
If hot water is not used, there is no gas consumption.
When the Heating button is pressed while in Hot Water mode, both functions can operate.
simultaneously.
When only the Hot Water mode is turned on, there will be no Heating.
The temperature of the hot water can be dangerously high when the volume of hot water is reduced.
suddenly. Therefore, DO NOT try to touch the water flow right at the tap opening.
hot
When the temperature of the hot water rises above 50 °C while the hot water is
in use, there is a risk of burns.
Do not clean the boiler and remote controls with a damp cloth.
There is a risk of an electric shock or malfunction in the boiler.
5turnConnect the power supply, then open the water supply valve and
on the boiler by pressing the Heating or Hot Water mode button.
When the boiler is not working properly, consult the troubleshooting table below before contacting the center.
authorized technical service.
Is there electrical power to the boiler? 1. Connect to the outlet with the correct voltage.
Is the lowest temperature lower than the current temperature? 2. Check the setpoint temperature and the current temperature.
Failure to Ignite 3. Is error [11] displayed on the screen? 3. Turn off the boiler and then turn it back on. If the same happens again
condition, please contact the authorized service center.
Is there gas supply to the boiler? 4. Open the gas supply valve, shut-off valve.
Is the boiler securely fastened to the wall? Fix and tighten the screws well.
2. Is the noise coming from the air intake/exhaust pipe? 2. Contact the technical service for maintenance.
Noise
3. Is the sound of water flowing inside the pipes 3. Open the air purge manually, which is on the upper side of the
too strong? distributor, to eliminate the air.
Is the selected temperature too low? Adjust the Hot Water temperature.
The water is not there 2. Is the hot water used in several places at the same time? 2. When used in Hot Water for several places at the same time, the
hot enough the volume of hot water decreases.
Is the amount of cold water mixture too much? 3. Adjust the amount of cold water to mix.
When the boiler is not working properly and an 'Error Code' appears on the screen, proceed to check the troubleshooting table.
problems that arise.
The use of ACS or drainage of Check the ACS or the water supply valves to ensure they are
Hot Water water in continuous form during correctly closed/open and there are no water leaks.
1 hour When the ACS is used continuously for 1 hour or more, the ACS symbol blinks.
Central Heating Heating filter blocked Clean the heating filter. (See page 17)
- Check if the gas shut-off valve is open. Turn off the heating mode and then,
11 Electric Ignition Failure
turn it back on.
Checkthegassupplypressure(Tryturningonothergasappliances)
Ignition failure more than
12 Heating and Domestic Hot Water Check that the ventilation and gas valve operate well.
20 times
Contact your gas supplier.
Security Circuit Stop the boiler for a maximum of 30 minutes, then press the mode of
Malfunction /Temperature heating or press the button in ACS mode.
14 Heating fuse malfunction Check if the heating cable is damaged.
overheating device of When the same condition repeats, please contact the service center.
protection authorized.
Check the water supply.
Check to ensure that the heating / ACS pipes are not frozen.
The air may not be suppressed enough, for this disconnect the boiler and then,
15 Heating Inadequate Water Circulation
connect it and start trial operation.
If no abnormal condition is detected, disconnect the boiler; then, connect it again.
and turn it back on.
Press either the heating button or the ACS mode button to turn it off and then turn it back on.
17 Heating Water Dispenser - Air Properly purge the installation.
Check the air outlet in the dispenser.
Press ACS or heating button to turn off and then turn back on. If the same thing repeats
20 Heating and ACS DIP S/W
condition to call authorized technical service.
31 Heating and ACS Error in the thermistor Check for a failure in the thermistor.
Press the button for either centralized heating or ACS mode to turn it off and then,
32 Heating and ACS Error in the thermistor turn it back on.
If the same condition repeats, please contact the authorized technical service.
When the boiler is not working properly and an 'Error Code' appears on the screen, proceed to check the troubleshooting table.
problems that arise.
Abnormal Frequency of Press the button for either central heating or ACS Mode to turn it off and then turn it back on.
94 Heating and ACS
energy If the same condition repeats, please contact the authorized technical service.
Check and make sure the water supply valve is opened. Disconnect first and then,
96 ACS ACSDetection Reconnect it to start the testing operation.
Check the water supply pressure.
- Press the button for either central heating or ACS mode to turn it off and then return.
97 Heating and ACS Error in the thermistor to turn it on.
If the same condition occurs again, please contact the authorized technical service center.
Check that the chimney duct is installed correctly, and that there are no blockages.
99 Heating and ACS Chimney Blockage
Check DIP S/W configuration
Installation Manual
Rinnai Eco RB 16/17 - 25/28 - 30/36
Table of Contents
Installation Manual 18
Precautions in Installation 19
Location of the Facility 20
Exterior Diagram 21
Electrical Wiring 23
Pipes 28
Installation of External Drivers 28
Trial and Confirmation Operation 29
Gas Change and Regulation 31
Main Replacement Parts 32
Electrical Diagram 33
RME-CL Combustion Regulation 34
INSTALLATION MANUAL
The installation and operation of this Rinnai boiler will be carried out in accordance with the gas boiler installation regulations and the
current regulations by SEC. Any condition not indicated will be made in accordance with this manual.
The boiler must be installed by a qualified technician in accordance with all applicable and authorized regulations and requirements.
by the SEC.
Inadequate pipes can lead to the escape of exhaust gases, which could result in poisoning.
carbon monoxide or the deterioration of the boiler.
The Company is not responsible for the malfunctioning of the boiler due to foreign substances in the tank.
the pipes that accumulate. Since the groundwater
It is used as a supply for heating. Therefore, it is recommended to thoroughly clean the pipes.
It is not recommended to use antifreeze solution, as it could deteriorate the boiler and its lifespan.
Refer to the installation of the boiler in the regulations of decree No. 66 of the superintendencies of electricity.
fuels.
2. When the boiler is connected directly to an air opening that is not blocked and is 300cm in size2surface.
3. For gas condensation in the chimney, it should be considered to install a condensate trap when it is greater than 2.
subways.
When multiple exhaust pipes / air intakes are installed, they must be
installed with a free space of at least 300 mm on the left and
right. From 600 mm above and below (type FE) to prevent the reversal of the
exhaust gases at the air intakes.
When the exhaust gases flow towards the air intakes, these
they could cause incomplete combustion, in turn, damaging
severely affects the lifespan of the boiler.
The boiler can only be installed in a space that meets the requirements.
appropriate ventilation prescriptions.
Wall installation
To install the boiler on the wall, the wall must contain concrete.
Do not install the boiler on common masonry or assembled walls.
lightweight concrete wall. Otherwise, it could transmit the vibration of the
caldera.
Pressure Indicator
(Manometer)
!
" #
/
$
%&'
Return / Heating
(PT 3/4" HE)
Drainage
Power Cable
Heating
Return Heating Supply Cold Water Entrance Hot Water Gas Output (Electric S.)
%&'
Electrical Wiring
Connect the boiler to a 220V AC power source. Contact a specialist in electrical installation.
classify in knowledge for electrical wiring.
If you do not use the power cord, connect the grounding wire to
a piece of metal and then bury it in damp soil with a
depth of (30 cm or more). Do not connect the ground wire to
a metal water pipe.
• Grounding cable: It must be a single core cable with the area of the
cross section of 1.15 mm2the superior.
In a territory of 110 V, if the unit is connected to 220V by increasing the voltage individually, the output must be
grounded. The transformer must be at least 1 kW/h or higher.
Gas Pipeline
The gas pipe installations must be carried out by a qualified and authorized gas installation specialist.
1) For the connection of the boiler and gas pipes, only the piping materials that have passed the
corresponding certification of gas appliances.
The gas pipe diameter must be 3/4"
3) After the gas pipes are connected, it is recommended to conduct a leak test that must be performed to ensure
that there are no gas leaks.
A gas shut-off valve must be near the boiler, where it allows
to access.
5) Standard pipe materials that have passed tests and certifications
Gas appliances required must be checked and sealed properly beforehand.
of its use. Be careful that the Teflon tapes do not remain inside the
gas pipes.
6) Be careful not to allow foreign substances to enter inside
the gas pipes.
It is recommended that the pipes should be wrapped with insulation materials with a thickness of at least 25 mm.
(in a cold climate region or territory: use 50 mm or higher).
Do not wrap a drain valve, water filter, or air escape valve with insulation materials.
• Si la caldera no se utiliza durante un largo período, Po favor drene toda el agua de las tuberías y desconecte la caldera.
Water Pipes
When the water supply pressure is insufficient, it is recommended to use an automatic water pump, do not install the
bomb in the boiler room. There is a risk of a possible fire.
Do not tape the connection area, to allow access for maintenance. The hot water pipe should be as short as possible and
It must be installed on a negative slope of 1/100 to 1/200 to drain correctly.
• Install the hydraulic shock absorption device where the hot water pipe is connected to the boiler, in order to
avoid damage to the pipe and/or the boiler caused by water hammer.
Heating Pipe
Heating pipes are generally buried in the ground. However, do not bury the connection area to allow access.
for future maintenance.
The diameter of a heat supply pipe must be the same as that of a water exchanger tube.
Install a drainage valve at the lowest point of the heating pipe to allow hot water to drain.
if necessary.
Connect a hose to the end of the water drainage outlet, so that the water coming out of the hose can flow.
towards the drain. Do not install a valve in the middle of the hose. There is a risk of water flooding.
Install an automatic air release valve or a manual air release valve at the part
superior of each radiator to prevent air or steam from filling the radiator.
Use a collector for radiant flooring with a manual or automatic bleeder at the top of the collector, so that it can
remove the air from the pipes of each room during the test operation.
Use only the designated inlet/outlet air for better performance, as it has been certified by the authority.
authenticated test. Do not change the appearance and/or structure.
As for the air intake pipes and air outlet pipes, never use corrugated pipes.
market aluminum. Use the sets of pipes and/or extension elbows offered by authorized distributors.
Rinnai.
The connections between the boiler and the air inlet pipes and/or the exhaust gas pipes must be connected.
correctly in order to prevent leaks and/or breaks. The joint must be with a rubber or similar gasket.
The union between the boiler and the air intake pipes and/or the gas exhaust pipes must be secure and firm.
Aluminum tapes and gypsum ties are not adequate preventive measures to avoid the spill and/or escape of gases.
The exhaust pipe must be tight enough after inserting the rubber ring to ensure that there are no leaks.
gas leaks.
The installer is responsible for damages or accidents that occur as a result of non-compliance with this.
installation instruction.
The top part of the Air Inlet / Outlet must protrude outwards and not be enclosed within the surface wall.
the installation.
For example, 1) use a 90-degree elbow and a 45-degree elbow for the
length of 3m.
Forced Firing
The top of the Air Inlet / Outlet must protrude.
outwards and not to confine oneself in the wall of the surface of
the installation.
The length of the vertical part (A) must be less than 700 mm. If it exceeds 700 mm, it must be wrapped.
with the fire-resistant and non-flammable insulation to retain heat. (For the prevention of the
Condensation of exhaust gases) The vertical length, in this case, will be up to 1,000 mm.
At the end of the connection, perform the functionality test to ensure that it works correctly.
Assemble in the reverse order of disassembly of the controller
Trial Operation
During the test operation, the symbol [– – ] appears on the screen. Do not press any button on the controller until
Complete the test operation. If the test operation needs to be carried out again, you must turn off the operations of
heating and hot water (by default) then disconnect the boiler controller and then reconnect it.
2. Clean the water pipes 2. Quite las particulas extrañas de las tuberías, especialmente el
Preparation Heating / Heating before the Trial operation. rust in the copper pipes.
3. Check once more to ensure there are no leaks. 3. Check the tension or voltage of the Boiler should be 220V.
gas, water or electricity. Check the type of gas (LPG or NG).
1. Open the valve of the heating pipe or that of the collector 1. Visually check for any leaks at the joints of the
water pipes, hot water pipes or heating pipes.
Open the water supply valve 4. To conduct the leak test covering the joint area of
Water inlet for the gas pipes with bubbles.
Heating / Hot Water
5. Open the collector room valve one by one and release the air. –
opening the air outlet valve of the manifold -
6. Turn on the Hot Water mode and then adjust the temperature.
from Hot Water.
Open the hot water valve to ensure that it is –
running the hot water and then, close the water valve
hot.
1. Check to ensure that the supply pipes 1. Check that the pipes are well insulated (connection between
Water and heating pipes are properly insulated. the boiler and the collector, and the boiler and the heating pipes
Check that the external appearance is correct
Thermostat and Finish.
2. Clean the area after completion 2. Check to ensure that the debris and waste
from the trial operation. have been eliminated.
Final Confirmation
5. Is a drainage hose connected? The hose should not be twisted. Also, the joint should not
Installation and Operation of Test
to be separated.
Is there a leak in the pipe? Check the gas pipes, water supply
warm and heating.
7. Are there any exposed pipes? Hot water pipes must be properly insulated to
reduce heat loss.
8. Does the combustion work correctly? Check that the outlet tube, air inlet, and of
ventilation that is not obstructed or bent.
3. Is the frost protection feature present? Refer to the frost protection in the manual
fully described? (Página 6)
4. Is the warning that deposits should not be made appropriate? Inspection of the location of the installed Boiler.
leave objects under the boiler?
Installed Boiler Inspection Is there any flammable object near the boiler? Check the installation of the board
Is the installation plate filled with the data? The installation form must be filled out with all the data of
corresponding and is attached to the boiler? corresponding installation and it must be attached to the
Check the Boiler (Plate)
boiler, for users and technicians to obtain the information
correspondent to its use.
Warning
You must ensure that the pressure indicator hole is completely sealed with the O-ring or pressure gauge bolt.
Must do Figure 1
Warning
You must check that the pressure indicator hole is closed.
completely with the O-ring or pressure gauge bolt
Warning
Ensure that there is no leak from the gas indicator.
Caution
If there is an incorrect setup, incomplete combustion or ignition,
it can produce an explosion, it can be dangerous.
3. Disassemble the gas collector and the damper and replace. Assemble.
reverse order of disassembly
Figure 2
Caution
When assembling the gas control, make sure it does not become loose or
how loose. The assembly must be perfect, not defective.
Electrical Diagram
mmH2O = mbar x 10
NOTE:
Gas consumption configuration
The gas consumption from the table is configured based on a pipe installation condition.
1 meter and a 90° elbow without the front cap.
Service Mode
1 Press and hold the button " " for 2 seconds
Then press the button " " for 2 seconds 2
1
Error Log 1
2
Press button " " for 2 seconds 1
2 Press button ' '
From the numbers '00 to 20', the last errors that occurred are shown.
No. 21 indicates the quantity error.