Structural Design Calculations Summary
Structural Design Calculations Summary
G 12/21/2025
Ceiling Floor 8
Top Floor 8
Member Size
Rafter 2x6
Rafter 2x8
G 12/21/2025
Dead Load 30
Live Load 50
Design summary
Overall design utilisation; 0.492
Overall design status; PASS
Dead
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 8 in
Depth of sections; d = 7.25 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Project Job no.
G 12/21/2025
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = 1.63 Lx + 3 b = 26.455 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Unbraced length - Minor axis; Ly = 16 ft
Effective bending length - Minor axis; Le,y = 1.63 Ly + 3 d = 27.892 ft
Column buckling length - Minor axis; Lb,y = Ly = 16 ft
Bearing length; Lb = 4 in
Analysis results
Design bending moment - Major axis; Mx = 500 lb_ft
Design shear force - Major axis; Vx = 100 lb
Adjustment factors - Table 4.3.1
Size factor for bending - Table 4A; CFb = 1.2
Depth-to-breadth ratio; dnom / bnom = 4.00
Slenderness ratio - eq.3.3-5; RB = (Le,y d / b2) = 32.841
Reference bending design value; Fb = Fb CFb KFb b = 2332 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value - cl.[Link]; FbE = 1.2 Emin' / RB2 = 1149 lb/in2
Beam stability factor - eq.3.3-6
CL = [1 + (FbE / Fb)] / 1.9 - [([1 + (FbE / Fb)] / 1.9)2 - (FbE / Fb) / 0.95] = 0.472
Format conversion factor for bending - Table 2.3.5; KFb = 2.54
Format conversion factor for shear - Table 2.3.5; KFv = 2.88
Resistance factor for bending - Table 2.3.6; b = 0.85
Resistance factor for shear - Table 2.3.6; v = 0.75
Time effect factor - Table N.3; = 0.6
Project Job no.
G 12/21/2025
Live
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 8 in
Depth of sections; d = 7.25 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = Lx = 16 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Project Job no.
G 12/21/2025
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.29 in
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.166 in
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.124 in
G 12/21/2025
Design summary
Overall design utilisation; 0.556
Overall design status; PASS
Dead
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Project Job no.
G 12/21/2025
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = 1.63 Lx + 3 b = 26.455 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Unbraced length - Minor axis; Ly = 16 ft
Effective bending length - Minor axis; Le,y = 1.63 Ly + 3 d = 27.455 ft
Column buckling length - Minor axis; Lb,y = Ly = 16 ft
Bearing length; Lb = 4 in
Analysis results
Design bending moment - Major axis; Mx = 200 lb_ft
Design shear force - Major axis; Vx = 100 lb
Adjustment factors - Table 4.3.1
Size factor for bending - Table 4A; CFb = 1.3
Depth-to-breadth ratio; dnom / bnom = 3.00
Slenderness ratio - eq.3.3-5; RB = (Le,y d / b2) = 28.379
Reference bending design value; Fb = Fb CFb KFb b = 2526 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value - cl.[Link]; FbE = 1.2 Emin' / RB2 = 1538 lb/in2
Beam stability factor - eq.3.3-6
CL = [1 + (FbE / Fb)] / 1.9 - [([1 + (FbE / Fb)] / 1.9)2 - (FbE / Fb) / 0.95] = 0.571
Format conversion factor for bending - Table 2.3.5; KFb = 2.54
Format conversion factor for shear - Table 2.3.5; KFv = 2.88
Resistance factor for bending - Table 2.3.6; b = 0.85
Resistance factor for shear - Table 2.3.6; v = 0.75
Time effect factor - Table N.3; = 0.6
Project Job no.
G 12/21/2025
Live
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = Lx = 16 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Project Job no.
G 12/21/2025
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.324 in
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.199 in
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.125 in
4X6(2-2X6) SUPPORT
In accordance with the ANSI/AF&PA NDS 2018 using the LRFD method
Tedds calculation version 2.2.22
Design summary
Overall design utilisation; 0.02
Overall design status; PASS
G 12/21/2025
Dead
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 4 in
Breadth of sections; b = 3.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 8 ft
Effective bending length - Major axis; Le,x = 1.63 Lx + 3 b = 13.915 ft
Column buckling length - Major axis; Lb,x = Lx = 8 ft
Unbraced length - Minor axis; Ly = 8 ft
Effective bending length - Minor axis; Le,y = 1.63 Ly + 3 d = 14.415 ft
Column buckling length - Minor axis; Lb,y = Ly = 8 ft
Analysis results
Design axial compression force; P = 300 lb
Adjustment factors - Table 4.3.1
Size factor for compression - Table 4A; CFc = 1.1
Reference compression design value; Fc = Fc CFc KFc c = 2424 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value; FcE = 0.822 Emin' / (Lb,y / b)2 = 1128 lb/in2
Column stability factor - eq.3.7-1
CP = (1 + (FcE / Fc)) / 1.6 - (((1 + (FcE / Fc)) / 1.6)2 - (FcE / Fc) / 0.8) = 0.409
Format conversion factor for comp. - Table 2.3.5; KFc = 2.4
[Link] for [Link] elasticity - Table 2.3.5; KFE = 1.76
Project Job no.
G 12/21/2025
Live
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 4 in
Breadth of sections; b = 3.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 8 ft
Effective bending length - Major axis; Le,x = Lx = 8 ft
Column buckling length - Major axis; Lb,x = Lx = 8 ft
Unbraced length - Minor axis; Ly = 8 ft
Effective bending length - Minor axis; Le,y = Ly = 8 ft
Column buckling length - Minor axis; Lb,y = Ly = 8 ft
Project Job no.
G 12/21/2025
Analysis results
Design axial compression force; P = 400 lb
Adjustment factors - Table 4.3.1
Size factor for compression - Table 4A; CFc = 1.1
Repetitive member factor - Table 4.3.9; Cr = 1.15
Reference compression design value; Fc = Fc CFc KFc c = 3231 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value; FcE = 0.822 Emin' / (Lb,y / b)2 = 1128 lb/in2
Column stability factor - eq.3.7-1
CP = (1 + (FcE / Fc)) / 1.6 - (((1 + (FcE / Fc)) / 1.6)2 - (FcE / Fc) / 0.8) = 0.319
Format conversion factor for comp. - Table 2.3.5; KFc = 2.4
[Link] for [Link] elasticity - Table 2.3.5; KFE = 1.76
Resistance factor for compression - Table 2.3.6; c = 0.9
Resistance factor for [Link] elasticity - Table 2.3.6; s = 0.85
Time effect factor - Table N.3; = 0.8
2X6 RAFTER
In accordance with the ANSI/AF&PA NDS 2018 using the LRFD method
Tedds calculation version 2.2.22
Design summary
Overall design utilisation; 0.608
Overall design status; PASS
G 12/21/2025
Live load deflection - C#3 results Unit Capacity Maximum Utilization Result
summary
Deflection in 0.533 0.141 0.264 PASS
Dead
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = 1.63 Lx + 3 b = 26.455 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Unbraced length - Minor axis; Ly = 16 ft
Effective bending length - Minor axis; Le,y = 1.63 Ly + 3 d = 27.455 ft
Column buckling length - Minor axis; Lb,y = Ly = 16 ft
Bearing length; Lb = 4 in
Analysis results
Design bending moment - Major axis; Mx = 300 lb_ft
Design shear force - Major axis; Vx = 100 lb
Adjustment factors - Table 4.3.1
Size factor for bending - Table 4A; CFb = 1.3
Project Job no.
G 12/21/2025
Live
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 2 in
Breadth of sections; b = 1.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Project Job no.
G 12/21/2025
Span details
Unbraced length - Major axis; Lx = 16 ft
Effective bending length - Major axis; Le,x = Lx = 16 ft
Column buckling length - Major axis; Lb,x = Lx = 16 ft
Unbraced length - Minor axis; Ly = 16 ft
Effective bending length - Minor axis; Le,y = Ly = 16 ft
Column buckling length - Minor axis; Lb,y = Ly = 16 ft
Bearing length; Lb = 4 in
Analysis results
Design bending moment - Major axis; Mx = 400 lb_ft
Design shear force - Major axis; Vx = 100 lb
Adjustment factors - Table 4.3.1
Size factor for bending - Table 4A; CFb = 1.3
Repetitive member factor - Table 4.3.9; Cr = 1.15
Depth-to-breadth ratio; dnom / bnom = 3.00
Slenderness ratio - eq.3.3-5; RB = (Le,y d / b2) = 21.664
Reference bending design value; Fb = Fb CFb Cr KFb b = 3873 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value - cl.[Link]; FbE = 1.2 Emin' / RB2 = 2639 lb/in2
Beam stability factor - eq.3.3-6
CL = [1 + (FbE / Fb)] / 1.9 - [([1 + (FbE / Fb)] / 1.9)2 - (FbE / Fb) / 0.95] = 0.628
Format conversion factor for bending - Table 2.3.5; KFb = 2.54
Format conversion factor for shear - Table 2.3.5; KFv = 2.88
Resistance factor for bending - Table 2.3.6; b = 0.85
Resistance factor for shear - Table 2.3.6; v = 0.75
Time effect factor - Table N.3; = 0.8
Project Job no.
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.356 in
Project Job no.
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.215 in
G 12/21/2025
Span details
Span length; Ls = 16 ft
Analysis results
Deflection - Major axis; x = 0.141 in
G 12/21/2025
4X6(2-2X6) SUPPORT
In accordance with the ANSI/AF&PA NDS 2018 using the LRFD method
Tedds calculation version 2.2.22
Design summary
Overall design utilisation; 0.02
Overall design status; PASS
Dead
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 4 in
Breadth of sections; b = 3.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Span details
Unbraced length - Major axis; Lx = 8 ft
Effective bending length - Major axis; Le,x = 1.63 Lx + 3 b = 13.915 ft
Column buckling length - Major axis; Lb,x = Lx = 8 ft
Unbraced length - Minor axis; Ly = 8 ft
Effective bending length - Minor axis; Le,y = 1.63 Ly + 3 d = 14.415 ft
Column buckling length - Minor axis; Lb,y = Ly = 8 ft
Project Job no.
G 12/21/2025
Analysis results
Design axial compression force; P = 300 lb
Adjustment factors - Table 4.3.1
Size factor for compression - Table 4A; CFc = 1.1
Reference compression design value; Fc = Fc CFc KFc c = 2424 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value; FcE = 0.822 Emin' / (Lb,y / b)2 = 1128 lb/in2
Column stability factor - eq.3.7-1
CP = (1 + (FcE / Fc)) / 1.6 - (((1 + (FcE / Fc)) / 1.6)2 - (FcE / Fc) / 0.8) = 0.409
Format conversion factor for comp. - Table 2.3.5; KFc = 2.4
[Link] for [Link] elasticity - Table 2.3.5; KFE = 1.76
Resistance factor for compression - Table 2.3.6; c = 0.9
Resistance factor for [Link] elasticity - Table 2.3.6; s = 0.85
Time effect factor - Table N.3; = 0.6
Live
Member details
Service condition; Dry
Sawn lumber section details
Number of sections in member; N=1
Nominal breadth of sections; bnom = 4 in
Breadth of sections; b = 3.5 in
Nominal depth of sections; dnom = 6 in
Depth of sections; d = 5.5 in
Material; Douglas Fir-Larch, 2'' && wider, Select Structural grade
Project Job no.
G 12/21/2025
Span details
Unbraced length - Major axis; Lx = 8 ft
Effective bending length - Major axis; Le,x = Lx = 8 ft
Column buckling length - Major axis; Lb,x = Lx = 8 ft
Unbraced length - Minor axis; Ly = 8 ft
Effective bending length - Minor axis; Le,y = Ly = 8 ft
Column buckling length - Minor axis; Lb,y = Ly = 8 ft
Analysis results
Design axial compression force; P = 400 lb
Adjustment factors - Table 4.3.1
Size factor for compression - Table 4A; CFc = 1.1
Repetitive member factor - Table 4.3.9; Cr = 1.15
Reference compression design value; Fc = Fc CFc KFc c = 3231 lb/in2
Adjusted modulus of elasticity; Emin' = Emin KFE s = 1032240 lb/in2
Critical buckling design value; FcE = 0.822 Emin' / (Lb,y / b)2 = 1128 lb/in2
Column stability factor - eq.3.7-1
CP = (1 + (FcE / Fc)) / 1.6 - (((1 + (FcE / Fc)) / 1.6)2 - (FcE / Fc) / 0.8) = 0.319
Format conversion factor for comp. - Table 2.3.5; KFc = 2.4
[Link] for [Link] elasticity - Table 2.3.5; KFE = 1.76
Resistance factor for compression - Table 2.3.6; c = 0.9
Resistance factor for [Link] elasticity - Table 2.3.6; s = 0.85
Time effect factor - Table N.3; = 0.8
G 12/21/2025