0% found this document useful (0 votes)
14 views1 page

Diesel Shed-Model

The document outlines a detailed plan for a maintenance facility, including dimensions, existing structures, and specifications for various maintenance tracks and cranes. It emphasizes the importance of adhering to written dimensions and provides notes on filling and construction guidelines. Additionally, it includes references to standards for measuring railway vehicle superstructures.

Uploaded by

ankit bhagat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views1 page

Diesel Shed-Model

The document outlines a detailed plan for a maintenance facility, including dimensions, existing structures, and specifications for various maintenance tracks and cranes. It emphasizes the importance of adhering to written dimensions and provides notes on filling and construction guidelines. Additionally, it includes references to standards for measuring railway vehicle superstructures.

Uploaded by

ankit bhagat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

KEY PLAN GENERAL NOTES

N
1 2 3 4
B 5 6 7 8 9 10 11 12
A 13 14
130000
60000 70000
10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000

70650 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS WRITTEN OTHERWISE.


A
2. NO DIMENSIONS SHALL BE SCALED FROM THIS DRAWING.
UWL

EXISTING 3T CRANE
1.5M WIDE PATHWAY
3. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.

EXISTING 3T CRANE
MAINTENANCE TRACK 8
WITH CRANE
OPTION: New
truck delivery
WS23.1
Security building
4. 0.00MM CORRESPONDS TO 284000 MM LVL

4.0
EL W

entrance to depot
(access gate 6.0
Gate no. 02
w=10m and
A
G.I POWDER COATED 10.0 Security building)

70.0
Measurement tracks
50m lengths
2.7
18300

CA EL W CA EL
Measurement-track according to

SHEET CLADDING ABOVE


"DIN 27202-10: State of railway vehicles - Superstructure and
special equipment of vehicles - Part 10: Measurement of

EXISTING PIT DEPTH


superstructures" tolerances for vehicles of category B

5. FILLING ONLY TO BE DONE FROM LINE NO. 3 TO 8. LINE NO. 1 & 2


UWL

3t crane
3t crane
Measurement track 50 m Pit Maintenance track 8 with crane
WS04.1 EL CA EL CA

TO BE REVISED 1.70M @ 8.00 M LVL FROM FFL


Maintenance bay CM Maintenance bay CM
Maintenance track 7 with crane

35.0
EL CA EL CA

Transport way
Maintenance bay PM Maintenance bay PM
Maintenance track 6 with catenary

12.0
WS04 EL CA EL CA

30.0 30.0 Maintenance bay PM Maintenance bay PM


Maintenance track 5 with catenary
62.5 12.0 G

5t crane
3.0

5t crane
has to be Kanban 195 m² 45.0
WS21 WS63 WS13
EL CA EL CA

8.3
removed 5.0

W
CA EL

Road existing Auxiliary Motor WS Electromech. WS Transport way 3.5 Compressor Compressor Automatic 45.0
WS13.1 ATW Train Washing
EL CA EL CA EL CA W EL CA EL CA EL CA

5.0
W CA

WS71 Manua
EL

EL CA EL CA

room 1 room 2 Washing Bay l Front

FLOOR IS ALREADY AT REQUIRED LEVEL.


Maintenance bay PM Maintenance bay PM Maintenance bay PM Maintenance bay PM
Technical

5.0
81.3
EL CA

Maintenance track 4 with catenary


W

8.0
EL CA EL CA EL CA EL CA
Room 30.0 EL CA
W

Maintenance bay PM Maintenance bay PM Maintenance bay PM Maintenance bay PM


Maintenance track 3 with catenary
G

36.5
EL CA

current Building size


EL CA EL CA EL CA

MAINTENANCE TRACK 7 H

Transport way
30.0 30.0 Maintenance bay OH Maintenance bay OH Maintenance bay OH Maintenance bay OH

50t crane

50t crane
25.0 70.0
Measurement tracks
30m lengths Maintenance track 2 with crane 5.0 WS38
WS11
WS36 Preparation Area and F F
W EL
CA
EL CA W EL CA W EL CA W EL CA W
Measurement-track according to

1.9
"DIN 27202-10: State of railway vehicles - Superstructure and
special equipment of vehicles - Part 10: Measurement of
Pre-cleaning pit

DN DN
superstructures" tolerances for vehicles of category B

Maintenance bay OH

Maintenance bay CM
Maintenance bay OH Maintenance bay OH Maintenance bay OH
W CA EL

10.0

5.6
painting booth

5.0 10.0
Maintenance track 1 with crane - 2.30

has to be EL CA W

6.0

4.00

1.5
WITH CRANE
EL

removed
CA W EL CA W

8.0 has to be has to be 3.5 J 24.0 J


WS36.1 PaintingTech and removed removed 108.0
Storage
EL CA W

has to be
H
WS06

15t crane

15t crane
15t crane Component workshop area Utility supply see Stabling Yard

18.3
removed
15.0 60.0 30.0

10t crane

10t crane
Logistic Area 2106 m²

12.0

W
(see details Floor plan Workshop) Floor plan

6. EXISTING ADMIN BUILDING GROUND FLOOR ALL ROOMS ENTRY RAMP

26.3

CA
Ha

EL
3.2 WS30
height 12m

27.0
2400 m² EL CA

BSC & Bogie Storage


EL CA EL CA EL CA
WS12
existing UWL ndo

5.00
ver

w=4.50
has to be has to be has to be

h=5.50

29.0
Asphalt Road

8.0

30t crane

30t crane
Utility supply see removed removed Component workshop area (GF) 847 m² min. crane hook height 8m
removed
Ya

EL
17.0
B B rd

CA
Floor plan 3132 m²

W
w=5.00 w=5.00
h=6.50 h=6.50 has to be 105.5 43.3

w=4.50
removed 10.0

h=5.50
35.4
D

20.0
D

22.6 6.0 130.0


Simulator & Training
Road Road

Boundary A

7.7
FGL
EL CA

78.0 WS61
W CA EL

10.0 has to be w=4.50 w=4.50


30.0 14.0 14.0 456 m² WS03

Ramp: 8%

13.0
removed h=5.50 h=5.50
Shunter WS23
garage Utility supply see Floor plan

7.9
EL W

5.0
WS10 WS17 130 m²
Security
C C
±0.00 M. Waste/Scrap Drum Storage Boundary 35.0 15.5 Roads should building Gate
36450

36450

4.0
W EL
EL W

container WS08 be connected no. 01


W EL

WS70First

TO BE PROVIDED.
suffiecient 6.0
Aid Room
HAZMAT 36 m²
width for New truck
delivery trucks

(284.00)
delivery entrance
storage WS01 to depot (access
gate w=10m and
Social / Admin security building)

40.0
Building Two 2W / 4W
Parking
Floor

B 1400has
floorremoved
height 4m
each
m²to be

EL
W
WS33

Road existing
EL W

Boundary

7. NUMBER OF SOLAR PANELS SHOWN ARE INDICATIVE.


SECTION SWITCH SECTION SWITCH

DN Maintenance bay CM DN
MAINTENANCE TRACK 6
WITH - OHE
8. FALSE CEILING, RE-PAINTING, FLOORING REPAIR, WATERPROOFING
G.I POWDER COATED
DIESEL SHED WILL BE DONE IN ADMIN AREA BY CONTRACTOR. ALSO NEW
18300

SHEET CLADDING EXISTING PIT DEPTH


TO BE REVISED 1.70M

SECTION SWITCH SECTION SWITCH


STAIRCASE TO BE PROVIDED AS SHOWN.
GENERAL NOTES CONTD.: -

TRANSPORT WAY
1.5M WIDE PATHWAY
G.I POWDER COATED FGL G.I POWDER COATED MAINTENANCE TRACK 5
DN Maintenance bay CM DN
90 Ø RAIN WATER
STEEL COLUMN AS PER SHEET CLADDING ±0.00 M. SHEET CLADDING WITH - OHE 1. ALL DIMENSIONS ARE IN MM.
[Link].& DET. (284.00)
90 Ø RAIN WATER 90 Ø RAIN WATER
DOWN TAKE PIPE
G.I. GUTTER ABOVE DOWN TAKE PIPE DOWN TAKE PIPE
2. DIMENSIONS SHALL NOT BE SCALED, ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
LADDER TO 59810 3. FOUNDATION OF BUILDING SHOULD BE DESIGNED FOR ONE FLOOR EXTRA.
ACCESS ROOF
C
4. ALL RCC WORKS FOR BUILDINGS WILL BE OF M-25 & STEEL SHOULD BE TMT FE-500 & ABOVE

LEGEND
G.I POWDER COATED STRUCTURAL STEEL - FE 240 (STANDARD ROLLED STEEL SECTION)
SHEET CLADDING ABOVE
AUXILIARY ELECTRO MECH. WS @ 8.00 M LVL FROM FFL -FE 315 (PLATED AND BUILT-UP SECTIONS)
5T CRANE

5T CRANE
30155X8160
OPEN

MOTOR WS
7600

29860X8160 G.I. GUTTER FFL FGL


5. WORK TO BE EXECUTED AS AS PER IS: 456-2000.
CAGE
LADDER
ABOVE ±0.00 M.
(284.00)
CAGE
LADDER
±0.00 M.
(284.00)
6. DOOR DIMENSIONS ARE TO BE MEASURED FROM FINISHED FLOOR LEVEL.
PROPOSED EXPANSION G.I POWDER COATED
7. WINDOW IN RELAY ROOM SHOULD BE PROVIDE WITH SLIDING GLAZED SHUTTER FROM INSIDE.
D
G.I POWDER COATED
SHEET CLADDING ABOVE
90 Ø RAIN WATER
DOWN TAKE PIPE
8. BAR BENDING SCHEDULE MUST BE PREPARED AS PER SP-34 AND DULY CERTIFIED BY SITE SHEET CLADDING
ENGINEER.
EXISTING AREA
5260

@ 8.00 M LVL FROM FFL RAIL TRACK 200MM WIDE DRAIN 200MM WIDE DRAIN EXISTING PIT DEPTH
AS PER DET. AS PER DET. TO BE REVISED 1.70M
SECTION SWITCH SECTION SWITCH SECTION SWITCH 9. CONCRETE MUST BE VIBRATED WITH MECHANICAL VIBRATOR.

99900
STAIRCASE TO BE
MAINTENANCE TRACK 4 DEMOLISH
DN MAINTENANCE BAY CM DN DN Maintenance bay CM DN
WITH - OHE 10. PROPER CURING MUST BE DONE.
PROPOSED M.S COLUMN
970 (PIT)

970 (PIT)
54200 (PIT -TYP)
NEW WALL TO BE
CONSTRUCTED
NEW WALL TO BE
CONSTRUCTED
11. FLOORING OF ROOMS OTHER THAN BATTERY ROOM TO BE DONE WITH VITRIFIED TILES (600X600MM)
OF MIN THICKNESS 9MM. PATHWAY
107100
18300

OPEN

TRANSPORT WAY
EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR
TO BE PLUGGED 1.2M WIDE PASSAGE TO BE PLUGGED 1.2M WIDE PASSAGE 1.2M WIDE PASSAGE TO BE PLUGGED 1.2M WIDE PASSAGE TO BE PLUGGED

12. FLOORING OF BATTERY ROOM TO BE DONE WITH ACID AND ALKALI RESISTANT TILES (800X500MM)
RAIL TRACK 200MM WIDE DRAIN
AS PER DET.
200MM WIDE DRAIN
AS PER DET.
EXISTING PIT DEPTH
TO BE REVISED 1.70M
UP
WATER

OF MINIMUM THICKNESS 9MM.


230MM THK WALL

7690
SECTION SWITCH SECTION SWITCH SECTION SWITCH TRAINING FFL STAIRCASE
LADIES REST +4.80 M.
PASSAGE MANAGER MAINTENANCE
DN MAINTENANCE BAY CM DN DN Maintenance bay CM DN MAINTENANCE TRACK 3 ROOM
5770 X 5800
OFFICE TRAINING ROOM-1 SSE (DIESEL)
LADIES
TOILET
GENTS
TOILET (288.80) TRAINING ROOM-2
23470 X 5800
MANAGER
IR OFFICER
CHAMBER
TEMPORARY
FILE STORAGE
OSHA ROOM SHIFT HEAD
OFFICER
TOILET
LADIES
TOILET
13. PLINTH LEVEL MUST BE DECIDED AS PER THE SITE CONDITIONS.
4770 X 5800
WITH - OHE 19770 X 5800 CHAMBER 2900 X 5800 6000 X 5800 6400 X 5800
4030 X 5800 2700 X 5800

EXISTING WALL TO BE DEMOLISHED


3920 X 5800 3920 X 5800 7100 X 5800
14. RAILING SHALL BE PROVIDED TO STAINLESS STEEL AS PER APPROVED BY ENGINEER IN-CHARGE.
970 (PIT)

970 (PIT)
PLANNING 4300 X 5800
TENDER DIESEL TRAINING CONFIDENTIAL OFFICER LADIES
MATERIAL SECTION TECHNICAL SECTION CONFERENCE HALL SSE (GENERAL) TOILET SECTION SR. DME OFFICE STAIRCASE ADME (D) SR. DME (D) DEE ADEE
SECTION ROOM CELL TOILET TOILET
5320

FGL
±0.00 M. FFL
CAGE
G.I POWDER COATED 15. GRANITE STONE PROVIDED ON JAMB & SILL FOR FULL WIDTH OF WALL FOR WINDOW.
G.I. GUTTER ±0.00 M. SHEET CLADDING ABOVE 106000
(284.00) ABOVE LADDER 16. GRANITE STONE IN RISERS, TREADS, LANDING AND ENTRANCE OF STAIRCASE.
(284.00) @ 8.00 M LVL FROM FFL
E PROPOSED FIRST FLOOR PLAN IN
G.I POWDER COATED EXISTING ADMIN BUILDING
17. INTERNAL WALL & CEILING TO BE TREATED WITH 2 MM THICK POP & PAINTED WITH DISTEMPER.
90 Ø RAIN WATER
SHEET CLADDING ABOVE
RAIL TRACK 200MM WIDE DRAIN
DOWN TAKE PIPE
200MM WIDE DRAIN SCALE 1:250 18. ALL EXTERNAL WALL PAINTED PREMIUM ACRYLIC SMOOTH WATER PROOF EXTERIOR FINISHED.
5240

@ 8.00 M LVL FROM FFL


AS PER DET. AS PER DET.
19. WATER PROOFING TREATMENT TO R.C.C. ROOF SLAB BY APPLICATION OF TWO COATS OF CEMENT SCHEDULE OF DOORS

EXISTING 50T CRANE


64150

DN MAINTENANCE BAY CM DN DN Maintenance bay CM DN


MAINTENANCE TRACK 2 SLURRY MIXED WITH WATER PROOFING COMPOUND (ACRYLIC BASED POLYMER, SOLID CONTENT
WITH CRANE
30% ±3, PH>7) IN THE RATIO OF 1:2 (1 PART OF WATER PROOFING COMPOUND : 2 PARTS OF CEMENT CLEAR OPENING
970 (PIT)

970 (PIT)

47599 (PIT)
BY WEIGHT), FOLLOWED BY TWO COATS OF SINGLE COMPONENT MOISTURE CURED POLYURETHANE
18300

EXISTING EXISTING PIT DEPTH


OPEN

50T CRANE
TO BE REVISED 1.70M
BASED ELASTOMERIC WATER PROOFING COATING CONFORMING TO ASTM C-836-89 HAVING TENSILE
RAIL TRACK 200MM WIDE DRAIN
AS PER DET. STRENGTH 3.1N/MM2. TOPPING LAYER OF 25MM THICK CEMENT CONCRETE [Link] TO BE LAID. TYPE WIDTH HEIGHT SWINGS DESCRIPTION NOS.
STAIRCASE TO BE

MAINTENANCE TRACK 1
DEMOLISH NEW WALL TO BE
CONSTRUCTED
20. ELECTRICAL SUB-STATION EQUIPMENTS CLE-TRANSFORMER, ELECTRICAL, SWITCHGEAR, CABLES
DN
MAINTENANCE BAY CM DN DN Maintenance bay CM DN
WITH CRANE 106000
EXISTING DOOR TO BE EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR
AND LOAD CALCULATION) WILL BE PROVIDED AS PER ELECTRICAL APPLIANCES CONSIDERED WIDE D3b 1000 2200 S.L. STEEL DOOR WITH VISION PANELS --
970 (PIT)

970 (PIT)

PLUGGED RAMP TO BE PLUGGED RAMP TO BE PLUGGED TO BE PLUGGED TO BE PLUGGED RAMP RAMP TO BE PLUGGED TO BE PLUGGED RAMP RAMP TO BE PLUGGED TO BE PLUGGED RAMP RAMP RAMP
GRADIENT GRADIENT GRADIENT GRADIENT GRADIENT GRADIENT GRADIENT GRADIENT GRADIENT
10% 10% 10% 10% 10% 10% 10% 10% 10%
47599 (PIT)
RLY. BD. LETTER NO. 2013/LMB/W/15.
5355

D4b
CAGE CAGE WS15 D-1 D-1 D-1 D-1 FFL
G.I. GUTTER
LADDER LADDER CLIMATE
PNEUMATIC TAPE CHANGER
UNNAMED UP
±0.00 M. 21. JPO NO. SECR/SET/ POLICY 889 DATED: 05.07.13 FOR JOINT PROCEDURE ORDER FOR UNDERTAKING
ABOVE STORAGE WS05 ROOM FIRST AID ROOM
WS19 (284.00) D4b 1200 2200 S.L. STEEL DOOR WITH VISION PANELS --

6260
WS07 WS16 WS14 5000 X 5800 TOILET (M)
LABORATORY TOILET (F)
F LUBE & FUEL
10000 X 5800
UNNAMED OIL SPECTRO
TOOL STORAGE
14770 X 5800 TOOL ROOM
UNNAMED 14770 X 5800
FRP GRID
CLEANING MUI BATTERY
CHARGING
UNNAMED STAIRCASE UNNAMED GOVERNOR ELECTRONIC
CONTROL EQUIPMENT
5290 X 5800
5235 X 5800 EARTH WORK IN THE VICINITY OF CABLES TO BE FOLLOWED STRICTLY.
UNNAMED 10770 X 5800 WORKSHOP

FGL
5088 UNNAMED 15752 X 5800 18628 X 5800 OVERHAULING
SECTION
STORE
22. S&T CLEARANCE SHOULD BE TAKEN PRIOR TO THE EXCAVATION WORKS.
EXISTING 15T CRANE

EXISTING 15T CRANE


±0.00 M.
23. ALL COLUMNS TO BE EXTENDED UPTO HEIGHT OF 900MM ABOVE THE ROOF TOP FOR FUTURE --
TRANSPORT WAY

WS26
1500 STEEL DOOR WITH VISION PANELS
D4b

D5b
D4b D4b

2200 D.L.
D4b

(284.00) WS18 BRAKE+COMPRESSOR


WS24 WS67 WS25 EXISTING WINDOW TO BE EXISTING WINDOW TO BE D-1 EXISTING WINDOW TO BE EXISTING WINDOW TO BE D-1 D-1 RAMP
EXISTING WINDOW TO BE
WS69 HVAC WORKSHOP EXTENSIONS.
GRADIENT
REMOVED & DOOR TO BE RAMP REMOVED & DOOR TO BE REMOVED & DOOR TO BE REMOVED & DOOR TO BE
COUPLER BUFFER WS REMOVED & DOOR TO BE
PROVIDED. PROVIDED.
GRADIENT
PROVIDED. PROVIDED.
10%
PROVIDED.
PANTO Damper workshop 20775 X 10015 FGL
10%

WORKSHOP WORKSHOP 62385 X 10000


15200 X 10015
WORKSHOP 6800 X 10015 FFL ±0.00 M. 24. ELECTRIC AND WATER PIPE LINE PLAN SHALL BE SUBMITTED AND APPROVED SEPARATELY BY FIELD
9990 X 10015 9990 X 10015 ±0.00 M. (284.00)
STAIRCASE TO BE
CONSTRUCTED
D-1 2000 2500 D.L. STEEL DOOR WITH VISION PANELS --
FFL (284.00) PROPOSED GROUND FLOOR PLAN
UNIT.
±0.00 M.
18300

OPEN

(284.00) IN EXISTING ADMIN BUILDING 25. AC OUT DOOR UNIT DRAINAGE SHOULD BE PROVIDED TO AVOID THE WATER LOGGING.
SCALE 1:250
26. WORK SHOULD BE STARTED ONLY AFTER APPROVAL OF STRUCTURAL DRAWING.
G.I POWDER COATED
TRANSPORT WAY TRANSPORT WAY TRANSPORT WAY TRANSPORT WAY SHEET CLADDING ABOVE 27. THE LOCATION OF LT PANEL (CHANGE OVER PANEL) AS PROVIDED BY ELECTRICAL DEPARTMENT
@ 8.00 M LVL FROM FFL
SHALL BE INSTALLED ON THE VERANDA AND THE LOCATION TO BE MARKED SUITABLY, PROVIDED

STAIRCASE TO BE
DEMOLISH NEW WALL TO BE
CONSTRUCTED
LADDER TO
ACCESS ROOF
BOTTOM MOST PART OF THE PANEL IS AT A HEIGHT NOT LESS THAN 2000MM.
28. THE OUT DOOR UNIT OF THE AC SYSTEM TO BE FIXED ON THE EXTERNAL WALL OF THE GOOMTY
FACING TOWARDS THE TRACK. THIS IS ESSENTIAL TO ENSURE ANTITHEFT ARRANGEMENT.
SOUTH EAST CENTRAL RAILWAY
G 106000

DIVISION : RAIPUR SECTION : DLS


EXISTING DOOR TO BE EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR
PLUGGED RAMP
GRADIENT
10%
TO BE PLUGGED RAMP
GRADIENT
10%
TO BE PLUGGED TO BE PLUGGED TO BE PLUGGED RAMP
GRADIENT
10%
RAMP
GRADIENT
10%
TO BE PLUGGED TO BE PLUGGED RAMP
GRADIENT
10%
RAMP
GRADIENT
10%
TO BE PLUGGED TO BE PLUGGED RAMP
GRADIENT
10%
RAMP
GRADIENT
10%
RAMP
GRADIENT
10% 29. THE EPOXY COATING FOR THE TRANSPORT WAYS AND THE REST OF THE FLOOR SURFACES IS
24455
90 Ø RAIN WATER STEEL COLUMN AS WS15 D-1 D-1 D-1 D-1
UNNAMED UP
D4b
FFL SHOWN IN DRAWING. THE YELLOW/BLACK LINES AND THE YELLOW LINES ARE TO BE APPLIED TO ALL
PNEUMATIC
8000

TAPE CHANGER
±0.00 M.
8000

8000
DOWN TAKE PIPE CLIMATE
PER [Link].&
STORAGE WS05 ROOM FIRST AID ROOM
(284.00) SURFACES AFTER FINISHING THE EPOXY COATING FLOOR.

6260
G.I POWDER COATED WS07 WS14 5000 X 5800 WS19 TOILET (M)
DET. 10000 X 5800 LABORATORY WS16 TOILET (F)
TOOL STORAGE BATTERY ELECTRONIC 5290 X 5800
SHEET CLADDING LUBE & FUEL UNNAMED OIL SPECTRO
14770 X 5800 TOOL ROOM
UNNAMED 14770 X 5800
FRP GRID
CLEANING MUI UNNAMED STAIRCASE UNNAMED GOVERNOR
CONTROL EQUIPMENT 5235 X 5800
10770 X 5800 CHARGING WORKSHOP

PROJECT :
UNNAMED
UNNAMED 15752 X 5800 18628 X 5800 OVERHAULING STORE
SECTION
FGL
±0.00 M. D4b D4b D4b D4b
H (284.00) RAMP
EXISTING WINDOW TO BE EXISTING WINDOW TO BE D-1 EXISTING WINDOW TO BE EXISTING WINDOW TO BE D-1 D-1 GRADIENT
EXISTING WINDOW TO BE
REMOVED & DOOR TO BE RAMP REMOVED & DOOR TO BE REMOVED & DOOR TO BE REMOVED & DOOR TO BE
REMOVED & DOOR TO BE 10%

DEVELOPMENT OF INFRASTRUCTURE FACILITIES FOR


GRADIENT
PROVIDED. PROVIDED. 10% PROVIDED. PROVIDED. PROVIDED.

STAIRCASE TO BE
CONSTRUCTED
A B C D E F G H
18300 18300 7600 18300 18300 18300 8000

MAINTENANCE OF ELECTRIC LOCOMOTIVES AT RAIPUR


G.I POWDER COATED G.I POWDER COATED
SHEET ROOFING SHEET CLADDING

G.I POWDER COATED [Link]


SHEET ROOFING
EL +15.40M
GROUND FLOOR PLAN (299.40)
SCALE 1:250 [Link] G.I POWDER COATED
E.L +12.40M SHEET CLADDING

7100
4215
1 2 3 4 5 6 7 8 9 10 11 12 13 14 [Link] TERRACE
E.L +8.19M T.O.C +8.30M
130000 (292.30)
G G

15400
TIN TIN
60000 70000
FIRST FLOOR

3500
10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000

12400
S S
XI XI
F.F.L. +4.80M
70650 (288.80)
E E

8190
B A OPEN OPEN OPEN OPEN
A

4800
GROUND FLOOR GROUND FLOOR
F.G.L / F.F.L. ±0.00M F.F.L. ±0.00M
(284.00) (284.00)

DRG TITLE :
SOUTH SIDE ELEVATION
SCALE 1:250
FGL -0.60M
(283.84) DIESEL SHED
18300

FLOOR PLANS, ELEVATION AND SECTIONS


A B C D E F G H
AND ADMIN AREA PLANS
36450

36450

B
SIGNATURE BLOCK
[Link]
E.L +12.40M
(296.40)
EXISTING 50T CRANE EXISTING 15T CRANE

CELE/SECR
FALSE CEILING AS PER
[Link]

3300
EXISTING 3T CRANE VENDOR SPECS. & DETAIL TERRACE
E.L +9.10M T.O.C +8.30M
18300

(293.10) (292.30)

3500 600
CATENARY LEVEL
G

3100
FIRST FLOOR
T IN E.L +6.00M
G G F.F.L. +4.80M

IS
(290.00)
TIN TIN ADMIN
(288.80)
CME(D&DM)/SECR
EX
ROOF WORKING ROOF WORKING ROOF WORKING
W
R
N
M
S
A
IA
.T
ER 90 MM Ø RAIN WATER G.I POWDER COATED SOLAR PANEL AS W
R
N
M
S
A
IA
.T
ER PLATEFORM PLATEFORM
IS PLATEFORM
IS
EX EX
F.F.L. +3.60M F.F.L.+3.60M F.F.L.+3.60M

GUTE
R AS PER DOWN TAKE PIPE SHEET ROOFING PER SPECS. & DET. GUTE
R AS PER
SPECS. & DET. SPECS. & DET. GROUND FLOOR 6000 CHIP

4800
CONVEYOR
GROUND FLOOR

3600

3600

3600

3600
LADDER TO F.G.L / F.F.L. ±0.00M F.F.L. ±0.00M
60160 (284.00) BRAKE+ ELECTRONIC
ACCESS ROOF CHIP EXISTING CARRIAGEWAY TO
BE DEMOLISHED
EXISTING CARRIAGEWAY TO
BE DEMOLISHED
KANBAN AREA TO BE
DEMOLISHED
EXISTING CARRIAGEWAY TO
BE DEMOLISHED
(284.00)
WORKSHOP
CPM/C/SECR
CONTAINER 1676 COMPRESSOR WS

150
C

1200

1200

1200

1200

1200
1400

1400

1400

1400

1400

1400

1400
FILLING FILLING FILLING FILLING FILLING FILLING

2300
EXISTING FLOOR LVL EXISTING FLOOR LVL EXISTING FLOOR LVL EXISTING FLOOR LVL EXISTING FLOOR LVL

850

850

850

850

850
CLEARANCE
1.5M WIDE PATHWAY
AS PER STRUCT.
FOR UWL BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
BOTTOM OF EXISTING PIT
BOTTOM OF 1.4M PROPOSED PIT
FGL -0.15M
SPECS. & DET. (283.85)
7600

CEE/CON/SECR RUKMAYA MEENA Digitally signed by RUKMAYA MEENA


Date: 2025.10.30 [Link] +05'30'
D SECTION AA
S L O P E S L O P E S L O P E S L O P E S L O P E S L O P E SCALE 1:250
SOLAR PANEL AS PER
DY. CEE/LOCO/SECR
99900

SPECS. & DET.

A B C D E F G H
Digitally signed by DEVANUJ SINGH
107100

18300 18300 7600 18300 18300 18300 8000


18300

G G.I POWDER COATED Dy. CEE/Con/R DEVANUJ SINGH TOMAR TOMAR


IN Date: 2025.10.30 [Link] +05'30'
SHEET ROOFING

I ST
EX
W
R
N
M
S
A
IA
.T
ER
S L O P E S L O P E S L O P E S L O P E S L O P E S L O P E
G.I POWDER COATED [Link]
GUTE
R AS PER SHEET ROOFING
EL +15.40M
SPECS. & DET.

[Link] G.I POWDER COATED


(299.40)
Dy. CE/Con-III/R
E.L +12.40M SHEET CLADDING

7100
E EXISTING 50T CRANE EXISTING 50T CRANE

TERRACE
Sr. DME(D)/R
4215

[Link] 5T CRANE
FALSE CEILING AS PER
E.L +8.19M
VENDOR SPECS. & DETAIL T.O.C +8.30M
(292.30)
G G

600
TIN TIN
64150

FIRST FLOOR

3500
STEEL COLUMN AS PER STEEL COLUMN AS PER
S S
XI XI
[Link].& DET. [Link].& DET. F.F.L. +4.80M
NG
ANKIT KUMAR BHAGAT Digitally signed by ANKIT KUMAR BHAGAT
I (288.80)
E E ST SSE/OHE/CON/R

8500
8190

I Date: 2025.10.30 [Link] +05'30'


EX
18300

S L O P E S L O P E S L O P E S L O P E

4800
5000
GROUND FLOOR GROUND FLOOR
WS69 F.F.L. ±0.00M
F.G.L / F.F.L. ±0.00M ELECTRO ELECTRONIC
Damper workshop (284.00)
SOLAR PANEL AS PER (284.00) MECH. WS WORKSHOP

600
SSE/W/CON/R
SPECS. & DET.

1400

1400

1400

1400
FGL -0.60M
(283.84)

1.5M WIDE PATHWAY RCC DRAIN PIT RCC DRAIN PIT


F

90 MM Ø RAIN WATER
AS PER STRUCT.
SPECS. & DET.
AS PER STRCT.
SPECS. DET.
AS PER STRCT.
SPECS. DET. SSE/D/R
DOWN TAKE PIPE SECTION BB
SCALE 1:250

G
IN
18300

S L O P E S L O P E S L O P E S L O P E S L O P E S L O P E 1 2 3 4 5 6 7 8 9 10 11 12 13 14

I ST
W
R
N
M
S
A
IA
.T
ER
EX W
N
A
R
T
E
AR
IS
M
.
G
UT
E
R AS PER
G.I POWDER COATED
SHEET ROOFING
W
N
A
R
T
E
AR
IS
M
.
G
UT
E
R AS PER
G.I POWDER COATED
SHEET ROOFING
W
N
A
R
T
E
AR
IS
M
.
G
UT
E
R AS PER
G.I POWDER COATED
SHEET ROOFING
GUTE
R AS PER SPECS. & DET. SPECS. & DET. SPECS. & DET.
SPECS. & DET.
[Link]
EL +15.40M
LADDER TO (299.40)
ACCESS ROOF
G G.I POWDER COATED
SHEET CLADDING
7100

G
TIN
TERRACE TERRACE
8000

8000

(OPEN TO SKY)
7295

7295

I S T.O.C +8.30M
G G
TIN IN
TOC

EX
+8.30 M. (292.30)
15400

S ST
XI I
FIRST FLOOR
3500

H
106000
F.F.L. +4.80M
(288.80) E EX
4800

GROUND FLOOR
F.F.L. ±0.00M
(284.00)

B A
ROOF PLAN FGL -0.60M
SCALE 1:250 (283.84) EAST SIDE ELEVATION
SCALE 1:250

M/S SIEMENS

DATE : 18/09/2025 SCALE: AS SHOWN DETAILED DESIGN DESIGNATION SIGN DESIGNATION SIGN DRAWING NO. :
CONSULTANT :
DRAWN (A) DESIGNED (B) CHECKED (C) TEAM LEADER SPECIALIST MEP CAO/C/BSP:-
R2 28/10/2025 COMBINED FORMAT
ARCHITECT SPECIALIST CIVIL
SIGN R1 05/10/2025 REVISION AS PER LETTER ON 30-9-25
KEY EXPERT- SPECIALIST TRACK
CONSULTING E- LOCO SYSTEM R0 29/09/2025 ISSUED FOR REVIEW AND APPROVAL
ENGINEERS GROUP KEY EXPERT- KEY EXPERT-
NAME An ISO 9001:2008 Company DESIGN OF CIVIL MECH (M&P) REV DATE DESCRIPTION OF REVISIONS CEG/DGN/D291/DLS/ARC/2001