ERBA H360 Hematology Analyzer Guide

The ERBA H360 is a compact 3-part hematology analyzer designed for CBC testing, featuring a 10.4-inch touchscreen and high precision in measuring RBC, WBC, and PLT. It requires minimal blood sample volumes and offers 22 parameters with both direct and calculated measurements. Good sample handling practices and basic troubleshooting tips are provided to ensure optimal performance and accuracy.

Uploaded by

hbasharsoft007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views9 pages

ERBA H360 Hematology Analyzer Guide

The ERBA H360 is a compact 3-part hematology analyzer designed for CBC testing, featuring a 10.4-inch touchscreen and high precision in measuring RBC, WBC, and PLT. It requires minimal blood sample volumes and offers 22 parameters with both direct and calculated measurements. Good sample handling practices and basic troubleshooting tips are provided to ensure optimal performance and accuracy.

Uploaded by

hbasharsoft007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd

ERBA H360 Hematology Analyzer

A Beginner's Guide for Sales,


Application, and Service Engineers
Introduction to ERBA H360

• 3-part Hematology Analyzer for CBC testing


• Measures RBC, WBC, and PLT with high precision
• Compact size with 10.4-inch touchscreen display
Blood Sample Types & Volumes

• Whole Blood: 9 μL
• Capillary Blood: 20 μL (via capillary tube/micropipette)
• Pre-diluted Blood: 20 μL (important for thicker samples)
• Lower sample volume saves reagent cost
Main Parameters Measured

• Total 22 Parameters:
• RBC-related: 8, WBC-related: 7, PLT-related: 6
• Directly measured: WBC, RBC, PLT, HB, MCV
• Calculated (e.g., HCT = (RBC × MCV)/10)
Machine Features

• Touchscreen operation (10.4 inch)


• Impedance method for cell counting
• Precision: WBC <2%, PLT <4% on retesting
• Carryover: <0.5%
Reagents & Consumables

• Diluent: For cell sizing and cleaning


• Lyse: Destroys RBCs/PLTs, frees HB, stains WBCs
• Onboard reagent stability: 60 days
• Loan reagent function: RFID machines only
Good Practices for Sample
Handling
• Use K2 EDTA tubes (2 mL)
• Roll blood samples for 8–10 minutes at 45 rpm
• Test within 2 hours (or refrigerate 2–8°C for max 7–8 hrs)
• Warm refrigerated samples to room temp before testing
Basic Troubleshooting

• No HB or WBC diff: Check Lyse first


• Low or missing results: Check Diluent
• Background requirements (WBC<0.2, RBC<0.02, etc.)
• Adjust MCV if HCT values are abnormal
Key Technical Specs

• Background: Ideally 0 (acceptable ranges provided)


• Carryover: Less than 0.5%
• Precision: High retest accuracy for WBC and PLT
• Small sample volume = lower reagent use