100% found this document useful (4 votes)
2K views125 pages

Fire Fighting Installation Measurement Rules

This document provides measurement rules for fire fighting installations. It discusses topics such as classification of fire fighting works, location of pipeworks, measurement of pipes and fittings, special connections, pipe supports, equipment and ancillaries. Specific fire fighting system components are also mentioned, including hose reel systems, fire alarm panels, brasswork, portable fire extinguishers, and more. Measurement rules are provided for various aspects of fire fighting installations to ensure compliance with relevant regulations and standards.

Uploaded by

Iqram Meon
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
2K views125 pages

Fire Fighting Installation Measurement Rules

This document provides measurement rules for fire fighting installations. It discusses topics such as classification of fire fighting works, location of pipeworks, measurement of pipes and fittings, special connections, pipe supports, equipment and ancillaries. Specific fire fighting system components are also mentioned, including hose reel systems, fire alarm panels, brasswork, portable fire extinguishers, and more. Measurement rules are provided for various aspects of fire fighting installations to ensure compliance with relevant regulations and standards.

Uploaded by

Iqram Meon
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
  • Introduction
  • Fire Fighting System Components
  • Measurement Rules
  • Fire Extinguishing Systems
  • Hose Reel Systems
  • Fire Extinguisher Types
  • Alarm Systems
  • Equipment and Ancillaries
  • Sundries
  • Taking Off Lists

FIRE FIGHTING INSTALLATION

DR. SARAJUL FIKRI MOHAMED

DEPARTMENT OF QUANTITY SURVEYING


FACULTY OF BUILT ENVIRONMENT UNIVERSITI TEKNOLOGI MALAYSIA

SBQ 3314 BUILDING MEASUREMENT III

Fire Fighting Installation System


Measurement Rules

SECTION Q
PLUMBING AND MECHANICAL ENGINEERING INSTALLATIONS

Measurement Rules
Section Q
Q.1 Information Q.2 Clasification Of Work Q.3 Location of works Pipeworks Q.7 Generally Q.8 Pipe and Fittings Q.9 Special Connection, etc Q.10 Labour Q.11 Sundries Q.12 Pipework Support Q.13 Connection Equipment and Ancillaries Q.19 Generally Q.20 Antivibration and sound insulation Q.21. Equipment support Q.22. Jointing Q.24. Identification plates Builders Work Q.31 Generally Q.32. Particularly

FIRE FIGHTING SYSTEM COMPONENTS


1. Builders Work 2. Hose Reel System Swing hose- reel, Water storage tank, Electrical duty pump, Diesel duty pump, Piping: incoming pipe -rising pipe, distribution pipe 3. Fire Alarm panel Manual Break Glass, Fire Alarm Bell, Batteries, Batery Charger
4. Brasswork Air release valve, Gate valve, Check valve, Strainer valve, Flexible joint 5. Portable Fire Extinguisher 6. Equipment and Ancillaries Concrete plinth 7. Pipe Support Pipe hanger 8. Sundries Testing

Fire Fighting Installation


MEASUREMENT RULES
R.2 Clasification of Work [Link] Fighting Installation

FIRE FIGHTING INSTALLATION

Standpipe

Sprinkler

Portable

Wet Standpipe

Dry Standpipe

Wet Pipe System

Dry Pipe System

Pre-action System

Deluge System

Hose Reel

- Water tank - Pump

- Water tank - Pump

- Pipes
- Sprinkler - Alarm

- Pipes
- Sprinkler - Fire Detector - Alarm

MEASUREMENT RULES
GENERALLY Q.1 INFORMATION FIRE FIGHTING INSTALLATION Generally Q.1. Information 1 Particulars of the following shall be given : a) Regulation, etc. b) Kind and quality of material. c) Gauge, thickness or substance of material. d) Any tests, etc.

THE FIRE PROTECTION SYSTEM INSTALLED ARE IN FULL COMPLIANCE AND REGULATIONS
1. The British Standards Institution 750 For Fire Hydrant 2. The British Standards Institution 5839 Part 1, 1980 For Fire Alarm System 3. The Requirements Of The Chief Inspectorate Of The Fire Services Malaysia.

MEASUREMENT RULES
Q.1.2 Assembling and jointing together the component parts of composite units and providing any necessary connecting flanges and jointing materials shall be deemed to be included with the items concerned. Where composite units are supplied by the Employer, particulars shall be given of the assembly work involved. Q.1.3 Patterns, moulds, templets and the like shall be deemed to be included with the items.

MEASUREMENT RULES
Q.1.4 Priming and painting off-site and proprietary finishes or surface treatment applied as part of the production process shall be described stating whether applied before or after fabrication or assembly. Q.1.5 Except where otherwise stated the method of fixing and the provision of nails, bolts, nuts, holes, screws, plugs, shot-fired pins and the like shall be given in the description of the work.

FIRE FIGHTING INSTALLATIONS

MEASUREMENT RULES
Q.1.6 The nature of the background to which work is to be fixed shall be given in the description. Any necessary drilling of the backgrounds shall be deemed to be included. Backgrounds shall be classified as follows :

a) Building-board which shall be deemed to include hardboard, compressed cement sheet, plasterboard, fibreboard and similar materials which do not grip woodscrews.

MEASUREMENT RULES
Q.1.6 The nature of the background . b) Timber which shall be deemed to include softwood, hardwood, blockboard, plywood and similar materials which will grip wood-screws when a lead-hole has been drilled.

c)
d) e)

brickwork, concrete or stone work


plain metal glass

MEASUREMENT RULES
Q.1.7. Temporary work shall be so described. Removing temporary work and making good after shall be deemed to be included with the item. 1.8. Connecting to existing services shall be described

MEASUREMENT RULES
GENERALLY Q.2. CLASSIFICATION OF WORK Q.2.1 Work together with its metalwork, supports and the like (unless associated with more than one installation) shall be classified as follows and given under an appropriate heading : d) Fire Fighting Installation

MEASUREMENT RULES
Q.3. LOCATION OF WORK Location of works : a. Internally b. Externally c. In plant rooms

MEASUREMENT RULES
PIPE WORKS Q.7 GENERALLY 1. Purpose-made pipes and purpose-made pipe fittings shall be described. 2. Pipes and pipe fittings which are wrapped, coated or lined by the manufacturer shall be so described stating the type of treatment. 3. Pipework required to be temporarily fixed in position, dismantled for chromium-plating or other special finishing and subsequently refixed shall be so described.

MEASUREMENT RULES
Q.8 PIPE AND FITTING 1. Pipes (measured over all pipe fittings, short running lengths and branches) shall be given in metres stating the type and the normal size.

Purpose-made pipe shall be so described and given separately. Curved pipes shall be so described stating the mean radius.
Joints in the running length shall be given in the description stating the method of jointing.

SETS OF FIRE FIGHTING EQUIPMENT

Portable FE
Hose Reel

MEASUREMENT RULES
Q.8 PIPE AND FITTING 3. Flexible pipes and extensible pipes (measured as fully extended) shall each be so described. 4. Pipes laid or fixed in ducts, trenches and chases or embedded in in-situ concrete or screeds shall each be so described.

PIPEfittings Pipe FITTINGS


Piping inside switch room

Conduit

Heat detector

Hose reel pipe

MEASUREMENT RULES
Q.9. SPECIAL CONNECTIONS, ETC. 1. Special connections and special joints in pipes shall each be enumerated separately (except where given in the description of another enumerated item) stating the nominal size and kind of pipe concerned and the method of jointing. Classification shall be as follows : a) Connections between pipes of differing materials and differing grades of the same material. b) Connections between pipes and appliances or equipment. c) Connections to existing pipes.

MEASUREMENT RULES
[Link] Labours on pipes (e.g. made bends, made springs, made offsets, beaded ends, ornamental ends, etc.) shall be deemed to be included with the pipes on which they occur.

MEASUREMENT RULES
Q.11 SUNDRIES 6. Pipe-sleeves through walls, floors ceilings shall be enumerated stating the type, lengths, the nominal size and kind of pipe passing through and the type of packing required, and if to be supplied for fixing by other trades, this shall be so described. 7. Wall, floor or ceiling plates shall be grouped together as plates and enumerated stating the type and size.

PIPE-SLEEVES

MEASUREMENT RULES
Q.12 PIPEWORK SUPPORTS 12.1 Standard pipe supports shall be given in the description of the pipes stating the type and spacing of the supports.

12.2. Non-standard pipe supports shall be described and enumerated (no).

MEASUREMENT RULES
Q.12 PIPEWORK SUPPORTS 4. Components or assemblies of components (e.g. clips, saddles, pipe-hooks, holderbats, brackets, rollers, chairs and hangers or black-plates and girder-lugs) used to fix supports for more than one pipe shall be enumerated separately stating the type and size of components. Spring compensated components shall be so described stating the loading and movement to be accommodated.

PIPEWORK SUPPORTS

PIPE SUPPORT

MEASUREMENT RULES
Q.13 CONNECTIONS Connections to public mains, making good public highway and any other work which may only be carried out by a Public Undertaking or Local Authority shall be given as a provisional sum.

MEASUREMENT RULES
EQUIPMENT AND ANCILLARIES Q.19 Generally 1. Unless otherwise stated, equipment such as boilers, generators, heaters, water treatment plant, tanks cylinders, calorifiers, pumps, coolers, air-handling unit, fans, refrigerator equipment, meters, sanitary fittings, etc. and ancillaries such as soot doors to boilers, valves and cocks, gauges, automatic controls etc. shall be enumerated and related to the specification referred to in clause Q.1.1.

MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES Q.19 Generally 2. Shall be described in conjunction with a manufacturers detailed specification (Q.19.2)

3.
4.

Any limiting dimensions on the size shall be given. (Q.19.3)


Electrical connection shall be given in accordance with section R . (Q.19.4)

DIESEL PUMP

Pengganti apabila pam operasi elektrik tidak dapat berfungsi. Stanby pump. 135 main flow, 40 m tekanan dan 2900 rpm Equipments and ancillaries, [Link] dinyatakan peralatan seperti tangki, silinder pam serta injap dan pili perlu di nyatakan. Unit NO

CO2 Fire Extinguishing Systems


Carbon dioxide fire extinguishing systems are used because of the most efficient extinguishing agents It is situated at the switch room It removes the oxygen and covers the surrounding atmosphere and literally strangles the fires to death. Advantages: a) odorless and non-toxic b) dry, inert gas, it will not conduct electricity c) cannot damage clothes or equipment nor contaminate liquids or food

HOSE REEL SYSTEM: WET PIPE

HOSE REEL SYSTEM


Pressurised using 1 unit of electrical pumpset as duty pump & 1 unit diesel engine pumpset as standby Designed to operate an automatic mode (Pressure switch) & manual mode (manual starting from the pumpsets control panel) Standard coil length 30m, 36m or 100m. Specification :Working Pressure : 220Psi (15 Bar) Minimum Burst Pressure : 696Psi (48 Bar) Test Pressure : 250Psi

Nozzles

Hose reel

Fire Hose Reel

Fire Hose Reel Pressure Reducing Valve Hose Guides

TYPICAL HOSE REEL

WET RISER Is constantly filled with water and the supply should be capable of maintaining a running pressure of 410kPa at the highest landing valve and give a flow rate of 23litres per second. The maximum running pressure permitted with one outlet open should be 510kPa. To maintain the required water pressure it is usually necessary to install pumping equipment. Direct pumping from the main is not permitted and a suction tank with a minimum actual volume of water of 45.5 m2 must be installed.

Hose reel

Piping

COMPONENTS

Brasswork

Water Tank

Pump:
Duty pump Standby pump

WATER STORAGE TANK

Equipments and ancillaries Clause Q.19. Unless otherwise stated, equipment such as tank shall be enumerated (no).

HOSE REEL

Hose reel wall mounted

VALVE

BIB

Horizontal

HOSE

General purpose synthetic delivery hose. Suitable for industrial and rural fire brigades as well as static building protection. General industrial, commercial and civil engineering applications including water authorities where a high burst performance hose is not necessary
Lightweight and flexible Heat and cold resistant Anti rot and anti-twist

BRANCH PIPE AND NOZZLE

Branch pipes provide an adjustable nozzle to allow the curtain of water to be altered from a narrow spray to a wide spray.
Nozzles provide a fixed jet of water. The basic branch pipe according to BS336 has an 21/2" inlet male instantaneous and outlet threaded 11/3" BSP male for either a plain jet or a branchpipe adjustable nozzle. The branch pipe is controlled from SHUT-OFF through JET and SPRAY to wide angle CURTAIN by rotating the annular sleeve.

HOSE REEL SYSTEM: DRY PIPE

System for dry riser This range includes:

inlet breechings inlet and outlet cabinets outlet valves standpipes, bars and keys.

DRY RISER COMPONENT


DRY RISER

Designed to house inlet breechings and landing valves Georgian wired glass panel and spring cylinder lock with key Manufactured from zintec, epoxy polyester powder coated - Red

FIRE EXTINGUSHER

FIRE EXTINGUSHER

Dry powder

Water

Type of Fire Extinguisher Gas Foam Carbon dioxide (CO2)

Portable Fire Extinguisher

PORTABLE FIRE EXTINGUISHER 1. Dry powder-No 2. Testing-item. CARBON DIOXIDE SYSTEM 1. CO2 cylinder-No 2. Testing-item.

POWDER EXTINGUISHERS

WATER EXTINGUISHERS

Foam extinguishers

Portable Fire Extinguisher.

Alat pemadam mudahalih (Portable Fire Extinguisher) digunakan melindungi bangunan dari bahaya kebakaran kecil.

Carbon Dioxide fire extinguisher

Portable Dry Chemical Powder Fire Extinguisher

Portable foam & water Extinguisher

ALARM SYSTEM

MANUAL ALARM
COMPONENTS Fire alarm panel Manual break glass Alarm bell

MANUAL BREAK GLASS

SMOKE DETECTOR

SMOKE DETECTOR
SMOKE DETECTOR

Fire alarm system is functioning as a components which give warning sign to occupants in a building if it is burning. It normally, installed with detector. There is 2 type of detector, passive (Manual break glass) and active (Smoke detector, heat detector, light detector).

LIGHT FITTINGS LIGHT FITINGS


Emergency light Keluar Sign

Flashing lights

SPRINKLER SYSTEM

Sprinkler system adalah sebuah sistem gabungan antara paip-paip yang dipasang di dalam bangunan dan sprinkler (overhead piping) bagi membolehkan ianya digunakan sebagai alat pemadam api. Alat-alat di dalam sistem : Tangki Air (gravity Tank). Fire Pump. Tangki Simpanan (Reservoir/Pressure Tank). Penyambungan kepada Bekalan Utama (Connection to Main/City Service).

MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES

Q.20 Anti-vibration and sound insulation


Anti-vibration mountings for plant shall be enumerated stating the type and the size. Anti-vibration material and sound-insulating material in plant bases shall be given in square metres stating the nature of the material and the thickness.

ANTI VIBRATION

MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES Q.21 Equipment supports 1. Equipment supports shall be enumerated and described. 2. Particulars of the method of fixing shall be given in the description in accordance with clauses Q.1.56.

FIRE HYDRANT & HOSE REEL

PORTABLE FIRE EXTINGUISHER (DRY POWDER)

MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES Q.22 Jointing Particulars of the method of jointing shall be given in the description of the equipment.

MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES Q.24 Identification Plates Identification plates shall be deemed to be included.

MEASUREMENT RULES
SUNDRIES Q.30 Generally 1. Draining and refilling existing system shall be given as a provisional or prime cost sum. 2. Disconnecting, setting aside and refixing equipment for the convenience of other trades shall be given as an item stating the relevant particulars.

MEASUREMENT RULES
SUNDRIES Q.30 Generally 3. Temporarily operating each installation (except for testing) shall be given as an item stating any required qualifications of the attendant, the duration of the operating period in hours and the purpose and particulars of any special insurance cover required by the Employer. Provision of solid fuel, liquid fuel, gas and electricity for power and lighting shall be deemed to be included with the item

MEASUREMENT RULES
SUNDRIES Q.30 Generally 4. Testing each installation shall be given as an item stating any required qualifications of the attendant, the number of stage tests in addition to the final, the purpose of the tests, the instruments and appliances required to be provided and particulars of any special insurance cover required by the Employer. Provision of solid fuel, liquid fuel, gas and electricity for power and lighting shall be deemed to be included with the item. 5. Preparing plans or diagrams of the installations as fitted shall be given as an item stating the kind of information required to be shown and the number of copies of each drawing required to be provided.

SCHEMATIC DRAWING

[Link] Detector [Link] Detector [Link] Nozzles [Link] Curtain (for Louver Door / Opening) 5. CO2 Cylinder c/w Accessories 6. Alarm Bell 7. Key Switch 8. Double Inter-lock Control Panel c/w Back 9. Normal / Discharge Light

MEASUREMENT RULES
BUILDERS WORK Q.31 GENERALLY 1. Unless otherwise stated, all items of builders shall be given in accordance with the appropriate section. Builders works in connection with plumbing and mechanical engineering installations shall be grouped together under an appropriate heading.

2.

MEASUREMENT RULES
BUILDERS WORK Q.32 PARTICULARLY 1. Excavating trenches for pipes not exceeding 55mm nominal size shall be given in accordance with clause D.12.9 2. For pipe over 55mm shall be given in accordance with clause V.2

3. Cutting away for making good after M&E works

SUMMARY OF SMM

SUMMARY OF MEASUREMENT RULES


CLAUSE ELEMENT METHOD UNIT

Q.1.1

All element

Shall be given in regulations, kind and quality of material, gauge, thickness or substance of material with any tests.

Q.1.2
Q.1.3 Q.1.4 Q.1.5

Assembling and jointing


Patterns, moulds, templets Priming and painting Nails, bolts, nuts, holes, screws, plugs, shot-fired pins

Connecting flanges and jointing shall include with the items.


Shall be include with the items. Described the work whether applied before or after fabrication or assembly.

In the description of work, stated the method of fixing.

SUMMARY OF MEASUREMENT RULES


Q.1.6 (a-f) a) building board b) timber c) metal-faced or compositionfaced timber d) brickwork, concrete or stonework e) plain metal f) glass Temporary work Connections

Shall stated the method of fixing and including the necessary drilling of the backgrounds and be given in the description.

Q.1.7 Q.1.8

Shall be include with the items ( removing temporary work and making good ) Shall be given in the description the nature of work, turning off supplies of any restriction when breaking into existing pipes. Given under an appropriate heading with its metalwork and supports.

Q.2.1

d) fire fighting installation

SUMMARY OF MEASUREMENT RULES


Q.3.1 All element The location for the work that must be identified : i) internally ii) externally iii) in plant rooms Measured all over the pipe fittings, short running lengths and branches stating the type and nominal size. Separate it if it is purposemade pipe. Curved pipe stating the radius. Joints shall be given in the description stating the method of jointing. Shall be described as extra over M

Q.8.1

Pipes

Q.8.2

Joints of a special characters and extra demountable couplers Flexible pipes and extensible pipes Pipes laid or fixed in ducts, trenches and chases

Nos.

Q.8.3 Q.8.4

Measured as fully extended and shall each be so described. Shall be described.

SUMMARY OF MEASUREMENT RULES


Q.8.5 Flow and return header pipe All measurement stating the length, type and nominal size of the main pipe and branch pipe and also method of construction and jointing the ends. All details, cutting and jointing shall be described. Nos.

Q.8.6

Pipe fittings and purpose made pipe fittings Expansion loops

Nos.

Q.8.7

All measurement stating the limiting dimensions Nos. and the amount of expansions to be accommodated. All measurement stating the type of joint and the amount of expansions to be accommodated. Necessary solely for erection purposes shall included. All jointing shall be deemed included with the items. All measurements stating he size and kind of pipe flanged concerned perforating Nos. Nos.

Q.8.8

Expansion compensators Flanges and unions Jointing Fittings and jointing

Q.8.9 Q.8.10 Q.8.11

SUMMARY OF MEASUREMENT RULES


Q.9.1 Special connections Special joints in pipes Measured separately stating nominal size, kind of pipe, method of jointing and must be classify a) Connections between pipes of different materials and difference grades and of the same material. b) Connections between pipes and appliances or equipment. c) Connections to existing pipes.

Q.9.2
Q.10

Isolated joints

As extra over stating the type of jointing

Made bends, made Shall included with the pipes on which they springs, made offsets, occur. beaded ends, ornamental ends, etc.

Q.12.1
Q. 12.2 Q.12.3

Standard pipe supports


Non-standard pipe supports Supports that are lined to insulate pipes

Shall described on the description of the pipes stating the type and spacing.
Shall be described. Shall described stating the type of lining material. Nos.

SUMMARY OF MEASUREMENT RULES


Q.12.4 Clips, saddles, pipehooks, holderbats, brackets, rollers, chairs, hangers/black plates, Gender-laps Enumerated separately stating the type and size Nos.

Q.12.5

Pipe anchor

Enumerated separately stating nominal size of pipe, type and size of components, method of fixing of the pipe and nature of work.
Work which may only carried out by Public Undertaking or Local Authority.

Nos.

Q.13

Connection

P.S

SUMMARY OF MEASUREMENT RULES


Q.15.1 Special connections, special joints Enumerated separately stating the size, kind of ducting and also method of jointing , classify ; a) Connections between ducting of differing materials. b) Connections between ducting and equipment stating the nature of the equipment. c) Isolated joints which differ from those given in the description of the ducting. d) Flexible connections between ducting and plant. Enumerated separately stating type and material size of ducting Shall described stating size, method of jointing and material and thickness or gauge Stating size and type, size of ducting and method of jointing. Nos.

Q.15.2 Q.15.3

Ducting turn and splitters Nozzle outlets, test holes and cores access doors Cowls, terminals, intake louvers

Nos. Nos.

Q.15.4

Nos.

Taking off list


_______________________________________________________________________________________________________________________

[Link] Reel System Swing hose reel Water tank Electrical duty pump Diesel standby pump Alarm bell

[Link] Work Ball float valve Strainer valve Stop valve Flexible connection Check valve Gate valve Pressure gauge

[Link] Work Incoming pipe Distribution pipe Rising pipe Painting to pipe

[Link] To Public Main [Link] work [Link]

Taking off List


_______________________________________________________________________________________________________________________

No.

ITEM

CLAUSE

UNIT

1.

Hose Reel System Swing hose reel Water tank Electrical duty pump Diesel standby pump Alarm bell

Q.19.1

Nos.

Taking off List


_______________________________________________________________________________________________________________________

No.

ITEM

CLAUSE

UNIT M

2.

Pipe Work Incoming pipe Distribution pipe Rising pipe Painting to pipes Pipe fittings

Q.7, Q.8.1

Q.8.6

Item Nos.

Taking off List


_______________________________________________________________________________________________________________________

No. 3.

ITEM Brass Work Ball float valve Strainer valve Stop valve Flexible connection Check valve Gate valve Pressure gauge

CLAUSE

UNIT

Q.19.1

Nos.

Taking off List


_______________________________________________________________________________________________________________________

No.

ITEM

CLAUSE

UNIT

4.

Connection to public main


Builders work Testing

Q.13

Provisional Sum

5. 6.

Q.31, Q.32.1 Q.30.4 Item

TAKING OFF LIST

1. Hose reel. 2. Water storage tank. 3. Electrical duty pump. 4. Diesel standby pump 5. Incoming pipe. 6. Main distribution pipe 7. Rising main pipe. 8. Distribution pipe. 9. Suction pipe. 10. Drain pipe.11. Ball float valve. 12. Strainer valve. 13. Stop valve. 14. Flexible connection. 15. Check valve. 16. Pressure gauge. 17. Pressure switch. 18. Automatic air release valve. 19. Cables. 20. Testing

-No -No -No -No -M .-M -M -M -M M -No -No -No -No -No -No -No -No -M -item

1. 2. 3. 4. 5. 6. 7.

Main fire alarm console panel. Manual break glass. Fire Alarm Bell. Heat detector. Smoke detector. Cables. Testing

-No -No -No -No -No -No -item.

TAKING-OFF LIST
1. 2.

3.

Preambles Builders work [Link] to receive hydrant pipe [Link] to receive incoming pipe Pipework [Link] pillar hydrant - 150mm dia. MSCL pipe laid in trench [Link] incoming pipe - 150mm dia. MSCL pipe laid in trench - 150mm dia. MSCL pipe laid on slab - 150mm dia. MSCL pipe fixed to wall [Link] pump house - 200mm dia. MSCL pipe laid on slab - 50mm dia. MSCL pipe laid on slab - 200mm dia. MSCL pipe fixed to wall - 50mm dia. MSCL pipe fixed to wall - 150mm dia. MSCL pipe fixed to wall

M M

M M M M M M M M M

TAKING-OFF LIST (Contd)


3. Pipework (contd) [Link] hosereel - 50mm dia. G.I pipe fixed to wall - 25mm dia. G.I pipe fixed to wall [Link] sprinkler - 150mm dia. G.I pipe fixed to ceiling - 100mm dia. G.I pipe fixed to ceiling - 80mm dia. G.I pipe fixed to ceiling - 65mm dia. G.I pipe fixed to ceiling - 50mm dia. G.I pipe fixed to ceiling - 45mm dia. G.I pipe fixed to ceiling - 32mm dia. G.I pipe fixed to ceiling - 25mm dia. G.I pipe fixed to ceiling - 150mm dia. G.I pipe fixed to wall - 25mm dia G.I drain pipe fixed to wall [Link] - Gate valve - Alarm valve M M M M M M M M M M M M NO NO

TAKING-OFF LIST (Contd)


Pipework (contd) [Link] inlet
4. 5.

NO NO

6.

7.

8.

Pillar Hydrant Hose Reel System [Link] hose reel [Link] duty pump [Link] standby pump Sprinkler System [Link] head [Link] tank [Link] duty pump [Link] jockey pump [Link] standby pump Conduits i. 2 x 2.5mm2 PVC cable in metal conduit ii. 2 x 1.5mm2 PVC cable in metal conduit Cable i. 2 x 2.5mm2 PVC cable in metal conduit ii. 2 x 1.5mm2 PVC cable in metal conduit

NO NO NO
NO NO NO NO NO M M M M

TAKING-OFF LIST (Contd)


9. Fire Alarm System [Link] gear [Link] box [Link] break glass [Link] alarm bell [Link] detector [Link] detector 10. Portable Fire Extinguisher [Link] powder extinguisher ii.CO2 extinguisher 11. Testing NO NO NO NO NO NO NO NO ITEM

FIRE FIGHTING SYSTEM


TAKING OFF LIST UNTUK HOSE REEL SYSTEM.

1. Builders Work a) Excavation 2. Hose Reel System a) Swing hose- reel b) Water storage tank c) Electrical duty pump d) Diesel duty pump e) Piping: incoming pipe rising pipe distribution pipe 3. Fire Alarm Panel Manual Break Glass Fire Alarm Bell Batteries Batery Charger

M No No No No M M M NO NO NO NO

FIRE FIGHTING SYSTEM


TAKING OFF LIST UNTUK HOSE REEL SYSTEM.

4. Brasswork Air release valve Gate valve Check valve Strainer valve Flexible joint 5. Equipment and Ancillaries Concrete plinth 6. Pipe Support Pipe hanger 7. Sundries Testing

No No No No No M2 NO Item

Fire fighting Installation system


Bill of Quantities

ITEM

DESCRIPTION FIRE FIGHTING INSTALLATION, TESTING, COMMISSIONING AND MAINTENANCE OF FIRE FIGHTING SYSTEM. HOSE REEL SYSTEM Swing hose-reel complete with 25mm diameter x 30mm long hose,12.5mm diameter nozzles, fixing, bracket, reducer, gate valve and other accessories as described. Hot-dipped galvanized pressed steel water storage tank of approved type, manufactured to BS 1564, 3.66m x 2.44m x 1.22m height with 2400 gallons capacity, complete with float valve, level indicator, ladder, overflow pipe and drain pipe, at approximately 1000mm high above ground level. Electrical duty pump, 30 igpm, 150 ft. head. Diesel standby pump, 32 igpm, 160 ft. head. TESTING Allow for testing the foregoing fire fighting system, make good any defects and leave the whole of the installation in perfect working order to the satisfaction of the S.O and Local Authority.

UNIT

QTY

RATE

RM

CENT

No.

20

No.

No.

No.

Item

Preambles

The drawing where the drawing no. FNP/BL/0205/F01-04 shows the layout of the fire fighting [Link] quantities are all provisional subject to remeasurement upon combination construction of the said item. The fire fighting system to be excuted by the contractor in accordance to Jabatan Bomba Malaysia requirement and approval. All wiring to brickwall and soffit of ceiling shall be concealed unless otherwise stated and all wiring above ceiling space of roof level shall be in galvanised iron conduit and coloured by red. The item of this bill not fully described and the rates shall be held to include for all short running, bend,tees,joints,valve,reducer,backnuts and the [Link] contractor must allow for testing fire fighting system and handling over the test certificate to the architect. The contractor shall be provide for obtaining all

necessary plan.

ITEM

DESCRIPTION FIRE FIGHTING INSTALLATION, TESTING, COMMISSIONING AND MAINTENANCE OF FIRE FIGHTING SYSTEM.

UNI T

QTY

RATE

RM

CENT

HOSE REEL SYSTEM


Swing hose-reel complete with 25mm diameter x 30mm long hose,12.5mm diameter nozzles, fixing, bracket, reducer, gate valve and other accessories as described. Hot-dipped galvanized pressed steel water storage tank of approved type, manufactured to BS 1564, 3.66m x 2.44m x 1.22m height with 2400 gallons capacity, complete with float valve, level indicator, ladder, overflow pipe and drain pipe, at approximately 1000mm high above ground level. Electrical duty pump, 30 igpm, 150 ft. head. Diesel standby pump, 32 igpm, 160 ft. head. TESTING Allow for testing the foregoing fire fighting system, make good any defects and leave the whole of the installation in perfect working order to the satisfaction of the S.O and Local Authority. No. 20

No.

No. No.

1 1

Item

Description ELEMENT FIRE FIGHTING INSTALLATION Fire-Fighting in connecting (internally) Fire Alarm system Manual Break glass fire alarm with 24 volts D.C supply, mounted at wall as described 150 mm Diameter fire alarm bell with 24 volts D.C supply, mounted as described Fire Fighting Equipment Lighting Installation (internally) KELUAR' Sign complete with nickel Cadmium batteries, tuber, etc and accessories with approved 13 W non-contained fluorescent Self contained Emergency Light fitting complete with nickel cadmium battery and outomatic charger unit similar econ lite Hose Reel system

QTY

Unit

Rate

APARTMENT J.B RM SEN

NO

NO

NO

NO

Hot Dipped Galvanised Pessed Steel Water Storage Tank of approved type, manufactured to BS 1564, 3m x 2m x 2m height with 2640 Gallons capacity, complete with 50 diameter overflow pipe,suction pipe, drain pipe incoming pipe at approximately 100 mm above ground level 1" Diameter Swing Type Hydraulic hose reel drums each c/w diameter x 100 ft. non. Kink double braided tubing and 1" diameter 3 jet spray nozzle Electrical Duty Pump, 30 IGPM, 120 ft head Diesel Standby Pump, ditto Galvanised Iron class 'B' Tubing to comply with BS 1387, screw socket together

NO

NO

G H

1 1

NO NO

50 mm Diameter incoming pipe, at High level free standing 50 mm Diameter overflow pipe,ditto

2.00

Description Galvanised Iron class 'B' Tubing to comply with BS 1387, screw socket together 50 mm Diameter suction pipe at low level, free standing 25 mm Diameter riser pipe fixed to brickwall 50 mm Diameter drain pipe at low level and jointing to Galvanised iron pipe

QTY

Unit

Rate

APARTMENT J.B RM SEN

B C

3 2

M M

Brasswork To Comply With BS 1010 as described :50 mm Diameter flexible connection and 2 jointing to galvanised iron pipe 50 mm Diameter Check valve, ditto 50 mm Diameter stop valve, ditto 50mm Diameter Ball float valve, ditto 50mm Diameter gate valve, ditto 50mm Diameter outomatic air release valve, ditto 50mm Diameter pressure gauge, ditto 50mm Diameter stairer valve, ditto BUILDER'S WORK 2 2 2 2 2

NO

E F G H J

NO NO NO NO NO

K L

1 2

NO NO

Wire brush and painting primer, undercoat and two coat gloss oil to surface of galvanised iron pipe Installation inclusive of hacking, punching of holes in wall and floors, coring of holes through reinforce concrete slab and making good Testing

Item

Item

Allow for testing foregoing fire fighting system, make good and any defects and leave the whole of the installation in perfect working order to the satisfaction of the S.O and Local Authority

Item

PROJEK
Cadangan Merekabentuk, Membina & Menyiapkan SMK Kenangan, Segamat, Johor, Di atas Lot 5848, 2259 Sebahagian Lot 5848 dan Sebahagian Lot 2258.

PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. ITEM DESCRIPTION ELEMENT : FIRE FIGHTING INSTALLATION (INTERNALLY) PREAMBLE ( All Provisional ) A The fire fighting installation is to be executed by contrator in accordance with Jabatan Bomba requirement and approval. Where items in this bill are not fully describes the rates shall be held to include for all piping, control gear and etc all as described or as required by Jabatan Bomba as being appropriate for installation. The rates be held to include for all short running lengths, bends, tees and etc. The contractor must allow for testing the fire fighting installation and handling over the test certifiate to the Architect. (Q.1) HOSE-REEL SYSTEM B Hydraulic hose-reel complete with 36 mm x 25 mm diameter long hose, 12.5 mm diameter nozzles, fixing, bracket, reducer, gate valve and other accessories as described. (Q.19) Electrical duty pump with 30 IGPM at 135 feet head. (Q.19) UNIT QTY RATE RM

Item

No No No

1 1 1

C D

Diesel standby pump with 130 IGPM at 135 feet head. (Q.19) Galvanised Iron Class 'B' Tubing to Comply With BS 1387 Screw Socketed Together Including All Necessary Short Length, Fire Bends, Tees, Dimishing Pieces, Plugs and The Like as Described.

50 mm Diameter incoming pipe laid in trench.

(Q.8)

13

F G

50 mm Diameter distribution pipe laid in ground slab.

(Q.8)

17

50 mm Diameter distribution pipe fixed in ceiling space horizontally with approved brackets. (Q.8) 50 mm Diameter distribution pipe fixed to brickwall vertically with approved brackets. (Q.8) 25 mm Diameter distribution pipe fixed to hidraulic hose-reel. (Q.8) EXTRA OVER 50 mm Diameter elbow. (Q.8.1)

23

17

M No

1 11

TO COLLECTION FF / 01

PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. ITEM DESCRIPTION ELEMENT : FIRE FIGHTING INSTALLATION (INTERNALLY) A B C EXTRA OVER 50 mm Diameter tee. EXTRA OVER 25 mm Diameter elbow. (Q.8.1) (Q.8.1) No No 1 2 UNIT QTY

(CONT'D) RATE RM

12 mm Diameter mild steel brackets at 600 mm centres to centres to support galvanised iron pipe. (Q.12.4) Brasswork to Comply with BS 1010 as Described.

No

68

50 mm diameter gate valve and jointing to galvanised iron pipe. (Q.19) Hot-dipped galvanised pressed steel water storage tank opproved type, manufactured to BS 1564, 12' x 4' x 8' height with 1000 gallons capacity, complete with float valve, level indicator, ladder, overflow pipe and drain pipe at ground level. (Q.19) Sundries Testing and commissioning the hose-reel system as described in the specification. (Q.30.4) PORTABLE FIRE EXTINGUISHER

No

No

Item

9 kg ABC extinguisher dry powder bomba approved type manufactured to BS 5306, complete with brackets and accessories. (Q.19) Sundries

No

Testing and commissioning the portable fire extinguisher as described in the specification. (Q.30.4) FIRE ALARM SYSTEM

Item

150 mm Diameter fire alarm bell with 24 V (D.C) supply mounted at wall as described. (Q.19) Manual break glass fire alarm size 84 mm x 115 mm with 24 V (D.C) supply mounted at wall as described. (Q.19) PVC Insulated Cable Drawn into Concealed Galvanised Iron Conduit. (measured separately)

No

No

2 x 2.5 mm2 cable. TO COLLECTION FF / 02

(Q.19.4)

54

PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. ITEM DESCRIPTION ELEMENT : FIRE FIGHTING INSTALLATION (INTERNALLY) Galvanised Iron Class 'B' Conduit with Screw Joints Including All Short Running Length, Bends, Tees, Saddles Crampets, Locknuts, Circular Boxes as Described. A 50 mm Diameter conduit, chase into brickwall vertically with approved bracket. (Q.19.4) 50 mm Diameter conduit, fixed in ceiling space with approved bracket. (Q.19.4) Sundries C Testing and commissioning the fire alarm system as described in the specification. (Q.30.4) BUILDER'S WORK D Excavate trench to receive 50 mm diameter incoming pipe, maximum depth nearest to 0.25 m including filling in, compaction and disposal of surplus soil as desribed. (Q.32.1) 600 mm thick vibrated reinforced conrete grade 20 as concrete plinth including all necessary formwork and reinforcement. (F.3.19) Allow for testing the foregoing fire fighting installation, make good any defect and leave the whole of the installation in perfect working order to the satisfaction of the S.O and Local Authority. (Q.30.4) UNIT QTY

(CONT'D) RATE RM

17

37

Item

18

m2

Item

TO SUMMARY FF / 03

Builders Work Excavate trench to receive pipe - M Hose Reel System Swing hose reel - NO Water storage tank - NO Electrical duty pump - NO Diesel standby pump - NO Piping 50 mm Diameter incoming pipe - M 50 mm Diameter rising pipe M 50 mm Diameter distribution pipe - M Brasswork 50 mm Diameter air release valve NO 50 mm Diameter gate valve NO 50 mm Diameter check valve NO 50 mm Diameter strainer valve NO 50 mm Diameter flexible joint NO 25 mm Diameter gate valve NO

Taking Off list

Cable

2 x 1.5 mm2 cable 2.5 mm2 cable Fire Alarm System Control gear NO Junction box NO Manual break glass NO 2 x 2.5 mm cable M 50 mm Diameter conduit M Portable Fire Extinguisher 9 kg Fire extinguisher - NO Hydrant Hose Cabinet NO Lighting Installation Keluar sign - NO 5A Emergency light NO Testing Allow for testing the foregoing fire fighting system - ITEM

Taking Off List

1. 2. 3. 4. 5. 6. 7. 8. 9. 10.

Pumps. Pipeworks. Tee Bend. Valves and ancillaries. Hydrant box. Pillar. Fire Extinguisher. Electrical Works. Testing.

- No -M - No - No - No - No - No - No - No - Item

1. Pumps - No

Equipment - Pumps

Electric Fire pump, end suction centrifugal


type with capacity of 750 GPM, 7 bar, 81 Kw/

108.7 Bhp.

No

(PU 202)

2. Pipeworks

150mm dia. Black steel pipe, ERW. Sch 40, embedded in in situ concrete m 130.00

130.00

(Pump Room)

Length 75,000 55,000 130,000

3. Fitting and Accessories


Tees

EXTRA OVER 150x150x65mm Black steel tee.

No

[Link]

Bend

EXTRA OVER Bend 90, to 150mm dia Black steel pipe

No

[Link]

[Link]
Hydrant

Indoor hydrant box size 800x1300x300mm, complete with house rack, hydrant valve and fire house type 40x25m. No 12

3 3

[Link]

3
3 3 3

L. Dasar

L. 1

3
3

L. 2

12

5. Fire Extinguisher

Fire extinguisher capacity 3 Kg complete with box, and all necessary supporting fixing

accessories as specified.

No.

52

13

L.B - L.2

52

6. Testing

Allow for checking, testing, acceptance testing and commisioning the Fire Protection Installation. Item

7. Maintenance

Allow for service and maintenance of the complete


installations during 12 months Defects Liability Period, excluding any maintenance resulting from defective workmanship or materials requiring repair

and/or replacement by contractor.

Item

Item

Description Element Fire Fighting Installation Builder's Work

Unit

Rate

Qtty

RM

Excavate trench to receive 150mm diameter incoming pipe, maximum depth not exceeding 1.0m including filling in, compaction and disposal of surplus soil as required.

17

Excavate trench to receive 50mm diameter Galvanised Iron class 'B' incoming pipe, maximum depth not exceeding 1.0m including filling in, compaction and disposal of surplus soil as described. Hose Reel System

Swing type hose reel drum with corrugated hose 30.5x25mm diameter complete with valve, bracket, 12.5mm diameter nozzle and other accessories as described.

no

Hose reel cabinet type SRI model HRS 045 or equivalent for all hose reel drum

no

Electrical duty pump with the capacity of 30 igm againts 170 ft static head complete with wiring, pump plinth and other accessories

no

Diesel standy pump with the capacity of 30 igm againts 170 ft static head complete with wiring, pump plinth and other accessories. One (1) nos of 2400 gallons of hose reel water tank, 6mm thick press steel panel complete with ball valve, fittings, level indicator, float control, piping, external red paint, internal asnd external ladder and other accessories.

no

no

To collection

Item

Description Galvanised Iron Class 'B' Tubing Screw Socketed Together Including All Necessary Short Length, Sockets, Connectors, Backnuts, Elbows And The Likes As Described

Unit

Rate

Qtty

Rm

150mm Diameter incoming pipe laid in trench (m/s) 50mm Diameter incoming pipe embedded into ground floor slab 50mm Diameter incoming pipe fixed to brickwall Brasswork To Comply To BS 1010 As Described

17

50mm Diameter air release valve and jointing to galvanised iron pipe 50mm Diameter check valve and jointing to galvanised iron pipe 65mm Diameter gate valve and jointing to galvanised iron pipe

no

no

no

To collection

Item

Description Fire Alarm System Installation Main fire alarm console panel (6 zones) complete with LED mimic diagram, battery compartment complete with 8 AHx24V and charger as manufacturer's detail. 400x400x150mm fixed to wall junction box approved type and quality, complete with 3mm thick galvanised steel covers, gasket and all other necessary accessories. Manual break glass fire alarm size 84mmx115mm with 24v(d.c) supply mounted at wall as described 150mm Diameter fire alarm bell with 24v (d.c) suplly mounted at wall as described Testing

Unit

Rate

Qtty

Rm

no

no

no

no

Allow for testing the foregoing fire fighting Item system, make good any defect and leave the whole installation in perfect working order to the satisfaction of the superitandant officer.

To collection

THANK YOU

You might also like