一、故障现象
XX移动Netapp Fas270硬盘故障, 0b.25号硬盘故障,需更换
mms-storage-1a> sysconfig -r
Aggregate aggr0 (online, raid_dp) (block checksums)
Plex /aggr0/plex0 (online, normal, active)
RAID group /aggr0/plex0/rg0 (normal)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0b.16 0b 1 0 FC:B - FCAL 10000 272000/557056000 280104/573653840
parity 0b.18 0b 1 2 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.20 0b 1 4 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.22 0b 1 6 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.23 0b 1 7 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.24 0b 1 8 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.27 0b 1 11 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.26 0b 1 10 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.29 0b 1 13 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.28 0b 1 12 FC:B - FCAL 10000 272000/557056000 280104/573653840
data 0b.32 0b 2 0 FC:B - FCAL 10000 272000/557056000 280104/573653840
Spare disks (empty)
Broken disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- &nb