Hagalo Usted Mismo Equipos de Bob Beck en Español
Hagalo Usted Mismo Equipos de Bob Beck en Español
El siguiente esquema e instrucciones se han editado del folleto original que Bob Beck puso a
disposición después de sus conferencias. Este manual ahora llamado "El Protocolo de Beck", está
disponible como descarga gratuita o se puede comprar una copia impresa.
Download Beck Protocol Handbook
Purchase Beck Protocol Handbook
Nota: Estos datos son solo para fines informativos e instructivos y no deben interpretarse como
consejos médicos. Consulte con su profesional de la salud con licencia. Miles se han construido
con éxito si se duplican exactamente como se muestra.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
La tercera sección es una salida de corriente continua de 27 voltios de corriente limitada de un conector RCA
(o 2.5 mm) separado para la generación rápida de excelente plata coloidal en agua. El método del agua de
calefacción aumenta la conductividad del agua destilada. Esto produce una plata coloidal iónica con un
tamaño de partícula pequeño.
El método de la sal con una pizca de sal se recomendó originalmente para aumentar la conductividad y
acelerar la fabricación de plata coloidal. Este método ha sido efectivo para muchas personas, pero los
tamaños de partículas son más grandes ya que la plata reacciona con la sal para formar cloruro de plata. Esta
solución puede no ser tan efectiva y, con el uso a largo plazo, el riesgo de argiria, un oscurecimiento de la
piel, es mayor.
Usar agua caliente o sal no acelerará el proceso con una unidad de corriente constante, ya que funciona
independientemente de la temperatura del agua.
La frecuencia del oscilador de 4 Hz de la sección U1A de OP-Amp se establece en C1 (0.1 uF) y R4 (2.4
Mega Ohm). Se configura como un comparador con histéresis determinada por R3 (150k Ohm). La carga y
descarga de C1 se realiza mediante la señal desfasada de 180º a través de R4. R1 y R2 proporcionan un
punto de ajuste 1/2 del V + al comparador. Esto asegura una onda cuadrada del ciclo de trabajo del 50% con
una amplitud ligeramente menor que la fuente de ~ 27 voltios.
U1B, el segundo comparador, se usa para invertir la salida del oscilador U1A. Se generará una señal de pico
a pico de ~ 54 voltios entre los OP-Amps debido a que sus salidas están desfasadas 180º. La corriente de
U1B está limitada por el potenciómetro SW1 (100k Ohm) y R5 (820 Ohm) y está configurada para la
comodidad del usuario individual.
El circuito indicador de alimentación consta de un LED bicolor (rojo-verde) (LED1) y la combinación en serie
de dos diodos Zener de 18 voltios, D1 y D2, con una potencia limitada por C2 (22uF, 35 voltios). Esta sección
del dispositivo se desactiva automáticamente cuando se inserta el conector de 3.5 mm en su conector. Por lo
tanto, los LED parpadean solo cuando la suma de las baterías es superior a ~ 21 voltios. Si los LED están
apagados o apagados, reemplace con tres baterías alcalinas de 9 voltios nuevas. C2 utilizado como limitador
permite que el LED parpadee a intervalos de 1/8 de segundo solo cuando la salida de onda cuadrada invierte
la polaridad.
Los usuarios encuentran que este diseño más nuevo es altamente satisfactorio, sin problemas y más
eficiente.
[Nota: este esquema no es una unidad de corriente constante y requiere el uso de un proceso de calor para
hacer plata coloidal iónica.]
U1 - OP AMP
Top View
Pin #1 Pin #8
LM358
Pin #4 Pin #5
Nota: Asegúrese de que el chip IC U1 (LM358) esté conectado correctamente. La ubicación del Pin # 1 se muestra arriba.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Cable conductor con conector de 3.5 mm, 6 pies, Mouser o Calrad Electronics
Para todos los componentes mencionados anteriormente, consulte su tienda de electrónica local. Si
una pieza no está disponible, es posible que tengan un reemplazo adecuado.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Unidad de electrificación de sangre actualizada con plata coloidal iónica de corriente constante
El único cambio a este diseño es usar la salida de corriente constante para hacer plata coloidal iónica.
Hay tres métodos para hacer plata coloidal iónica: corriente constante, agua de calefacción y sal. Para
este diseño, se utiliza el método de corriente constante. Con la corriente constante, se puede utilizar
agua destilada a temperatura ambiente. El proceso no se acelera calentando el agua o agregando sal.
La corriente constante produce una solución de plata de alta calidad que es en gran parte plata iónica.
La forma iónica asegura un tamaño de partícula muy pequeño, una forma que el cuerpo parece
absorber fácilmente.
La primera sección (U1A) del amplificador doble OP LM358 es un oscilador de onda cuadrada pico a
pico de 54 (2 x 27 voltios por ciclo). La segunda sección (U1B) invierte la polaridad y proporciona una
salida de ± 27 voltios CC de baja impedancia. Esto ofrece una salida bifásica de tiempo de subida
brusca de ~ 4 Hz (no crítica) para los electrodos biológicos de acero inoxidable recubiertos de algodón
saturados con agua salada antes de la aplicación. El tiempo de subida brusca se considera necesario
para proporcionar armónicos impares más altos al estímulo, aunque las formas de onda "redondeadas"
se sentirán diferentes. Vea la página 2 para un diagrama de U1.
La tercera sección es una salida de corriente continua de 27 voltios de corriente limitada de un
conector RCA (o 2.5 mm) separado para la generación rápida de excelente plata coloidal en agua. Un
ciclo de tres minutos en 8 oz. de habitación-temperatura del agua hace una concentración de ~ 3-5
ppm. [Este tiempo se basó en agregar sal al agua para aumentar la conductividad. Más tarde, se
recomendó calentar el agua, en cambio, para mantener el tamaño de partícula más pequeño.]
La frecuencia del oscilador de 4 Hz de la sección U1A de OP-Amp se establece en C1 (0.1 uF) y R4
(2.4 Mega Ohm). Se configura como un comparador con histéresis determinada por R3 (150k Ohm). La
carga y descarga de C1 se realiza mediante la señal desfasada de 180º a través de R4. R1 y R2
proporcionan un punto de ajuste 1/2 del V + al comparador. Esto asegura una onda cuadrada del ciclo
de trabajo del 50% con una amplitud ligeramente menor que la Fuente de alimentación de ~ 27 voltios.
U1B, el segundo comparador, se usa para invertir la salida del oscilador U1A. Se generará una señal
de pico a pico de ~ 54 voltios entre los OP-Amps debido a que sus salidas están desfasadas 180º. La
corriente de U1B está limitada por el potenciómetro SW1 (100k Ohm) y R5 (820 Ohm) y está
configurada para la comodidad del usuario individual.
El circuito indicador de alimentación consta de un LED bicolor (rojo-verde) (LED1) y la combinación en
serie de dos diodos Zener de 18 voltios, D1 y D2, con una potencia limitada por C2 (22uF, 35 voltios).
Esta sección del dispositivo se desactiva automáticamente cuando se inserta el conector de 3.5 mm en
su conector. Por lo tanto, los LED parpadean solo cuando la suma de las baterías es superior a ~ 21
voltios. Si los LED están apagados o apagados, reemplace con tres baterías alcalinas de 9 voltios
nuevas. C2 utilizado como limitador permite que el LED parpadee a intervalos de 1/8 de segundo solo
cuando la salida de onda cuadrada invierte la polaridad.
Los usuarios consideran que este nuevo diseño es altamente satisfactorio, sin problemas y más
eficiente.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Esquema actuallizado para la unidad de electrificación de sangre con salida de plata coloidal
Nota: este esquema usa el método de corriente constante para hacer la plata coloidal
Copyright © 2015 Bob Beck Legacy Assocation
iónica.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Cable conductor con conector de 3.5 mm, 6 pies, Mouser o Calrad Electronics
Para todos los componentes mencionados anteriormente, consulte su tienda de electrónica local. Si
una pieza no está disponible, es posible que tengan un reemplazo adecuado.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Sugerencias para adquirir y usar un generador de pulso magnético de acoplamiento inductive para la neutralización
teórica de patógenos linfáticos y tisulares
Revisión Enero 15, 1997. Copyright © 1991/1997 Robert C. Beck, D.Sc.
Revisado Enero de 2015 por Bob Beck Legacy Association
De acuerdo con los enfoques hipotéticos de autoayuda de bajo costo, los medios más simples y rápidos para
obtener un condensador-descarga teórico magnético con pulso magnético y neutralizador de patógenos
tisulares serían encontrar y modificar una flash electrónico portátil que funcione y que funcione con corriente
alterna (luz estroboscópica) para cámaras. Estos se adquieren en reuniones de intercambio, ventas de garaje,
casas de empeño o en cajas de chatarra en tiendas de cámaras usadas. O compre un nuevo modelo 1900 de
Vivitar (marca) en algunas tiendas de cámaras profesionales. Este flash compacto, ligero, de bajo costo y de
recarga rápida es de solo 17.5 Watt * Segundos (julios: calculado como ½ CV2 donde C está en
microfaradioss, mF o mfd., Y V está en voltios) pero está disponible y se puede modificar fácilmente. Funciona
lo suficientemente bien para un uso informal, pero funciona solo con baterías, por lo que tiene un mayor costo
operativo que una unidad de CA / CC.
Los precios de los swaps de California para las luces estroboscópicas usadas varían de $ 4.00 a
aproximadamente $ 18.00. Un domingo, el escritor encontró una docena de luces estroboscópicas AC / DC,
todas en buenas condiciones de funcionamiento. Lleve cuatro baterías AA con usted para que pueda probar
las unidades de flash antes de comprarlas. Casi cualquier marca o modelo de potencia de salida comparable
(17 a 35 vatios * segundos) debería funcionar. Preferiblemente, seleccione uno con 115 VCA así como la
capacidad de funcionamiento de la batería (CC).
Primero enrrolle la bobina aplicadora. Los carretes de videocasete VHS son baratos, abundantes y adecuados para
esta aplicación. Retire los 5 tornillos de la carcasa, quite los carretes y deseche la carcasa. Asegúrese de que
los carretes alternativos (si se usan) no sean conductores (deben ser de plástico) o el sistema no funcionará.
Evite los carretes de cinta VHS de longitud más corta, que pueden tener cubos centrales mayores de 1 "de
diámetro. y no tendrá suficiente cable. Perfore orificios de ¼ ”a través del cubo y del centro de la (s) brida (s).
Haga dos discos de 4 "de ¼" de plástico grueso, metal, madera contrachapada o tableros de fibra rígida,
taladre orificios centrales de ¼ "y otro orificio de ¼" fuera del centro, de modo que pueda tirar del cable
conductor interior de la bobina mediante. Estos "refuerzos" deben emparedar las bridas del carrete con fuerza
para que no se deformen o se dividan a medida que la presión del cable se acumula mientras el bobinado
avanza. Una tuerca y perno de máquina de ¼-20 de 2 ”(o más) con arandelas a través de los centros sujetará
los refuerzos de la brida y el carrete y también proporcionará un eje para sostener un motor de perforación de
velocidad variable o un dispositivo de devanado similar si se usa. Retire los pernos y refuerzos cuando haya
terminado.
Especificaciones:Llene completamente el carrete de cinta con el alambre de cobre esmaltado # 14 o
# 16 (130 a 160 vueltas) enrollado en el diámetro de 1 ". buje y carrete de 3-½ "OD con un ancho de
espacio para el cable de 5/8". Raspar el esmalte aislante a ½ ”en las puntas y estañar. Tire del extremo
interior del alambre del imán a través del cubo y el refuerzo y hacia el exterior. Aproximadamente 1-½
”debe llenar el carrete. Retire el perno, los refuerzos y la bobina terminada. Ahora suelde a cada extremo
de la bobina el cable de extensión de 4 pies de largo. Una bobina terminada # 14 pesa alrededor de 1 lb. 3
onzas, tiene una inductancia de 0,935 milihenios, resistencia de 0,34 ohmios y tarda aproximadamente 20
minutos en enrollar a mano o unos 3 minutos con el motor de perforación.
© 2008 - 2015 Bob Beck Legacy Page 8 of 10 www.bobbeck.com • [email protected]
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Una excelente alternativa es un inductor de cruce de núcleo de aire de AMS para audio para el hogar, MCM
Electronics, Centerville, OH 45459, (800) 543-4330 nº de catálogo 50-940, calibre 16, 0,58 ohmios, 2,5 mH, 2-7 /
8 Dia.
Para Usar presione la bobina completamente aislada contra el cuerpo sobre los ganglios linfáticos y otras
ubicaciones seleccionadas. Deje que la luz estroboscópica se acumule a plena carga (aproximadamente de 4 a
10 segundos entre pulsos) y destelle mientras presiona la bobina sobre cada sitio seleccionado. Los sujetos no
sentirán sensaciones físicas, excepto los "golpes" ligeros durante esta fase de electrificación. Los niveles de
exposición se consideran seguros porque la intensidad de este pulsador magnético es mucho menor que
la de la Imagen de Resonancia Nuclear Magnética en el uso rutinario de decenas de miles de pacientes
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.
Bob Beck Legacy
Pero si el sujeto se siente como "loco", tiene náuseas, es lento o muestra una gripe los síntomas después
de las exposiciones con cualquiera de estos dos dispositivos, reduzca la cantidad de pulsos o la duración
del proceso de depuración de la sangre y beba agua ozonizada. Si el sistema inmunológico está muy
dañado, es posible que deba repetir todas las rutinas después de varios meses para asegurar la
neutralización. Cuando lo use, mantenga la bobina a varios pies de distancia de las tarjetas de crédito,
relojes, cintas magnéticas, computadoras, disquetes, remedios homeopáticos, etc., ya que su potente
campo magnético puede desactivar y borrar los datos magnéticos, así como los medicamentos potentes con
energía sutil. Como una casualidad inesperada, se informa que los pulsadores borran patologías linfáticas y
tisulares muy arraigadas y posiblemente incluso "miasmas" clásicos, así como muchos otros microbios,
hongos, bacterias, parásitos y virus. Preferiblemente, el flash se debe usar con corriente alterna para
ahorrar costos de batería, ya que solo obtendrá unos 40 pulsos completos por cada nuevo conjunto de
baterías alcalinas. Para fines sanitarios, incluya la bobina en una bolsa de plástico desechable con cierre de
cremallera. Cuando se trata a numerosos sujetos, si no hay un adaptador de CA, es económico utilizar una
pequeña batería de "motocicleta" de plomo y ácido recargable.
Recomiendo el pulsador del fabricante [SOTA Instruments Inc.] que es muy superior a hacer uno con un
flash fotográfico. Las salidas medidas en un osciloscopio digital en tiempo real TDStronics TDS 210 y un
amperímetro RMS Wavetek AD105 con abrazadera son: Capacitor de almacenamiento de energía: 600uF,
450 voltios DC, almacenamiento de energía típico: 36.75 julios (vatios * segundos), almacenamiento de
energía máximo: 42.18 julios (vatios * segundos), voltaje de carga máximo típico: 350 voltios DC, voltaje de
carga máximo máximo: 375 voltios de corriente continua, descarga máxima de corriente máxima en la
bobina : 150 amperios RMS, Tiempo de aumento del pulso: <1.8 uS (microsegundos), Duración del pulso: ~
2.5mS (milisegundos), Inductancia de la bobina principal: ~ 2.5mH (mili-henries), Densidad de flujo: 40,500
amperios * Giros, campo magnético pico Salida: ~ 6,000 Gauss (~ 6 kilo Gauss) según lo medido con un
medidor de Tesla de Bell 5080 de F.W., cantidad mínima de descargas de impulsos 30 millones
(30,000,000). Penetra unas 9 pulgadas a través del tejido.
.
Disclaimer: Please understand we are not health practitioners. By reading the information on this site you are agreeing that you take full
responsibility for any decision you make because of it. Any information shared is based on science, hearsay, testimonials, lay people and
professionals. The content provided on this site is for informational purposes only and is not intended to diagnose, treat or cure any medical
condition. Please consult your health practitioner. Government regulators say that testimonials are misleading and deceptive. Results are not typical.