RRU3004 V300R008&R009
Installation Guide
Issue: 04 Part Number: 31504593 Date: 2009-07-15
HUAWEI TECHNOLOGIES Co., Ltd.
Contents
1Safety Information 2Installation Tools 3Installing the DC RRU3004 Space Requirements (Unit: mm) Installation Modes Installation Procedure Preparing for the installation Installing the RRU on a Metal Pole Installing the RRU on a Wall Installing the RRU on a U-Steel Installing the RRU on an Angle Steel Installing the DC RRU3004 for capacity expansion Installing the RRU on an H-shaped stand Cable Connections of a Single RRU Cable Connections of Multiple RRUs Cable Connections of two Cascaded RRUs Cable List Installing the RRU Cables RRU Cable Installation Scenarios 4Installing the AC RRU3004 Space Requirements (Unit: mm) Installation Modes Installing the Surge Protection Box (for Outdoor Scenarios) Cable Connections of a Single RRU Cable Connections of Multiple RRUs Cable Connections of two Cascaded RRUs List of Cables (No Surge Protection Box Configured) List of Cables (Surge protection box Configured) Installing the RRU Cables Installation Checklist 5 Powering On the RRU 6 Reference Binding the RRU and Installation Components Making OT Terminals by Using a Cable Peeler (Recommended) Making OT Terminals at the Input End of the Power Cable by Using a Knife Installing the corrugated pipes of AC power cable Pin Assignment for the Wires of the RRU Alarm Cable (DC) 7Changes in the RRU3004 Installation Guide
2 3 4 4 5 6 6 7 10 11 11 12 14 16 16 17 17 20 22 30 30 30 31 35 36 36 37 38 40 42 43 43 43 45 46 47 47 48
Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved.
Safety Information
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility of accidents. The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be followed. They only provide the generic safety precautions for operations. When operating Huawei products and equipment, you must comply with safety precautions and special safety instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use.
Complying with the Local Safety Regulations
When operating the device, comply with the local safety regulations. The safety precautions provided in the documents are supplementary. You must comply with the local safety regulations.
Qualified Personnel Only
The personnel in charge of installation and maintenance must be trained and master the correct operating methods and safety precautions before beginning work.
Symbols
DANGER WARNING CAUTION TIP NOTE
Indicates a hazard with a high level of risk, which if not avoided,will result in death or serious injury. Indicates a hazard with a medium or low level of risk, which if not avoided, could result in minor or moderate injury. Indicates a potentially hazardous situation, which if not avoided,could result in equipment damage, data loss, performance degradation, or unexpected results. Indicates a tip that may help you solve a problem or save time. Provides additional information to emphasize or supplement important points of the main text.
Safety of Personnel
The high voltage power supply provides power for running the system. Direct contact with the high voltage power supply or contact through damp objects may result in fatal danger. Non-standard and improper high voltage operations may result in fire and electric shock. In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel tower and mast. Ground the device before powering on the device. Otherwise, the personnel and device are in danger. Power off the device before performing operations on the power supply equipment. High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all parties to ensure that the transmitter antennas are shut down. When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes. Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust. Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. When working at a height, be cautious about falling objects.
Device Safety
Check the electrical connection of the device before operation and ensure that the device is reliably grounded. The static electricity generated by the human body may damage the electrostatic sensitive components on the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when performing the operation. When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss. The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards. When the equipment is unpacked, it must be powered on in 24 hours. The maximum duration of the poweroff state of the equipment is 24 hours during maintenance.
Installation Tools
Insulated screwdriver
Cross screwdriver
Straight screwdriver
Adjustable wrench
Socket wrench
Torque wrench
Power cable crimping pliers
RJ-45 crimping pliers
Wire cutter
Rubber hammer
Claw hammer
Cable peeler
Percussion drill
Heat gun
Level bar
Multimeter
Long measuring tape
Vacuum cleaner
Installing the DC RRU3004 a
Space Requirements (Unit: mm)
2. Recommended Clearance for a Single RRU
1. RRU Dimensions
3. Minimum Clearance for a Single RRU
4. Clearance for Two Combined RRUs
Installing the DC RRU3004 b
Installation Modes
On a metal pole
On a wall
On an angle steel
On a U-steel
DC RRU3004 for capacity expansion
on an H-shaped stand
The following figure describes the specifications for the metal pole, angle steel, and U-steel where the RRU is installed.
the angle steel or U-steel
As shown in the figure, the angle between the vertical and the angle steel or Usteel where the RRU is installed must be less than 10 degrees.
Metal pole
Angle steel
U-steel
The following figures show the installations of multiple RRUs on the metal poles.
A maximum of two RRUs can be installed on a metal pole with the diameter of 60 mm to 76 mm, and the RRUs must be installed on the back. Only one RRU can be installed on a U-steel or angle steel at the back.
A single RRU can be lifted to the tower. For details, see page 43.
WARNING 1. The maximum bearing capability of the wall equals four times of the RRU weight, and a single RRU3004 weighs 17 kg. 2. When the RRU is mounted on the wall, tighten the expansion bolts to 30 Nm. Ensure that the expansion bolts are properly tightened and there is no crack on the wall.
Installing the DC RRU3004 c
Installation Procedure
Start
Prepare the installation
Install the cables of RRU
Power on the RRU
End
Preparing for the Installation
Auxiliary fixture
Cover plate
Attachment plate
Main fixture
Dual-nut bolt assembly
Fixture assembly for installing the RRU
Front of the RRU
Back of the RRU
Installing the DC RRU3004 e
Installing the RRU on a Metal Pole
1. Install the main fixture.
1. When installing the main fixture, ensure that the contact piece on the fixture is fixed. 2. When installing the main fixture, ensure that the arrow on the main fixture is upward.
It is recommended that the bottom of the highest main fixture be 1200 mm to 1600 mm above the ground for easy maintenance. Arrow
2. Install the auxiliary fixture between the nuts of the dual-nut bolt assembly on the main fixture.
Ensure that the arrow on the auxiliary fixture is upward. dual-nut
TIP: You may fit one end of the auxiliary fixture on one dual-nut bolt assembly and then the other end on the other dual-nut bolt assembly during the installation.
Installing the DC RRU3004 e
Installing the RRU on a Metal Pole
3. Use an adjustable wrench to tighten the nut until the fastening torque is 40 Nm. In this way, the main and auxiliary fixtures are secured on the pole.
40Nm
Fasten the two dual-nut bolt assemblies alternatively. After the brackets are secure, use a tape to measure the spacing between the main bracket and the auxiliary bracket at the two sides and ensure that the spacing is the same.
4. Install the RRU on the main bracket. When you hear a click, you can infer that the RRU is in position.
The screw is a non-fixed one and can be neglected during the installation. It is only used when the RRU is removed.
The RF port at the bottom of the RRU does not have load bearing capacity. Do not place the RRU on the ground on its bottom during the installation.
Installing the DC RRU3004 e
Installing the RRU on a Metal Pole
5. Install the main fixture of another RRU. Ensure that the main and auxiliary fixtures are perfectly fitted.
When the surfaces of the main and auxiliary brackets are in the same plain, you can infer that the main bracket is properly installed.
6. Install the second RRU on the main fixture.
The screw is a non-fixed screw
Cabling cavity
Ensure that the cabling cavities of the two RRUs face the reverse direction when installing the RRUs.
Installing the DC RRU3004 f
Installing the RRU on a Wall
2. Drill holes at the anchor points and then install the expansion bolt assemblies.
1. Place the auxiliary fixture on the wall at the installation position and then mark the anchor points by using a marking pen.
Bolt M1065 Spring washer 10 Plastic tube Flat washer 10 Expansion tube
After the expansion bolt is removed, dispose of the plastic tube.
It is recommended that the bottom of the auxiliary fixture be 1200 mm to 1600 mm above the ground. 3. Fit the auxiliary fixture on the expansion bolts downward, and then tighten the bolts by using a combination wrench (17 mm 17 mm).
Do not hammer the bolt entirely into the expansion tube, and leave 20 mm to 30 mm of the bolt outside the wall.
4. Install the main bracket, and then use a level bar to adjust the levelness of the bracket.
5. Install the RRU.
M10X65
30Nm
10
Installing the DC RRU3004 g
Installing the RRU on a U-Steel
Top view
U-steel
Four installation modes
The procedure for installing the RRU on a U-steel is the same as that on a metal pole. Only one RRU can be installed on a U-steel at the back.
Installing the RRU on an Angle Steel
Angle steel
Top view
The procedure for installing the RRU on an angle steel is the same as that on a metal pole. Only one RRU can be installed on an angle steel at the back.
11
Installing the DC RRU3004 i
Installing the DC RRU3004 for capacity expansion
2. Remove the cover plate from the RRU.
1. Remove the adapting piece from the RRU housing.
3. Remove the screws from the RRU housing, and press the latches to remove the housing.
12
Installing the DC RRU3004 i
Installing the DC RRU3004 for capacity expansion
4. Remove the screws from the handle, and then remove the handle. As shown in the figure, change the way of installing the handle. Then, tighten the screws.
Inner hexagon spanner(48kgfcm)
5. Remove the cover of the RRU3004 subrack, slide the optional RRU into the subrack, tighten the screws, and then reinstall the cover of the subrack.
When sliding the RRU into the rack, ensure that the DIN connector on the RRU do not contact the beam on the rack. Align the RRU on the guide rails.
13
Installing the DC RRU3004 j
Installing the RRU on an H-shaped stand
2. Adjust the levelness of the stand. 3. Install the horizontal beam. 1. Secure the stand.
Pretightening
Tightening
The horizontal beam on the other side is installed in the same way.
14
Installing the DC RRU3004 j
Installing the RRU on an H-shaped stand
5. Mount the RRU on the main bracket
4. Install the main bracket.
Expansion bolt
RRU
Use expansion bolts to fasten the main bracket. Ensure that the expansion tubes and plastic tubes must be removed before the expansion bolts are installed. Use the expansion bolts in the installation kit delivered with the RRU. Do not use other types of expansion bolts. When the RRU is installed on a wall, the angle between the wall and the RRU cannot exceed two degrees.
Installing the support
6. Install the RRU.
Do not install three or four RRUs on a single H-shaped stand.
15
Installing the DC RRU3004 k
Cable Connections of a Single RRU
Boolean/RS485 input cable CPRI optical cable Power cable Interconnect jumper AISG multi-wire cable RF jumper Feeder AISG extension cable PGND cable
Antenna
External power supply
External alarm device
When a dual-polarized antenna is shared by two RRUs in the same sector, the two RRUs are connected through an inter-RRU jumper. The connections of three RRUs in the same sector are not supported.
Cable Connections of Multiple RRUs
External power supply
CPRI optical cable Power cable RF jumper PGND cable SFP high-speed cable for cascaded RRUs Boolean/RS485 input cable
Antenna
Antenna
Antenna
External power supply When two or more RRUs need to be cascaded in the same cell (or in the scenario for capacity expansion), the alarm cables need to be connected to the RRU in the lowest level for alarm reporting.
16
Installing the DC RRU3004 m
Cable Connections of two Cascaded RRUs
Antenna
SFP high-speed cable for cascaded RRUs PGND cable for cascaded RRUs Interconnect jumper Power cable for cascaded RRUs RF jumper CPRI optical cable Power cable PGND cable
Cable List
Connector Type
Two OT terminals
Cable
Power cable for cascaded RRUs
Connected to
The blue wire is connected to the NEG(-) port in the cabling cavity of the upper-level RRU, and the black wire is connected to the RTN(+) port in the cabling cavity of the upper-level RRU. The blue wire is connected to the NEG(-) port in the cabling cavity of the lower-level RRU, and the black wire is connected to the RTN(+) port in the cabling cavity of the lower-level RRU.
Two OT terminals
SFP high-speed cable for cascaded RRUs
SFP200 male connector SFP200 male connector
the CPRI_E port on the upper-level RRU the CPRI_W port on the lower-level RRU
17
Installing the DC RRU3004 n
Cable List
Connector Type
OT terminal OT terminal
Cable
PGND cable
Connected to
Grounding bolt on the RRU Nearest grounding bar
Equipotential cable
OT terminal OT terminal
Grounding bolt on the RRU Grounding bolt on the RRU
RF jumper
DIN male connector DIN male connector
Ports labeled ANT_TX/RXA and ANT_RXB on the RRU Feeder or antenna
Power cable
Two OT terminal
The OT terminal on the blue wire is connected to the NEG(-) port on the cabling cavity of the RRU. The OT terminal on the black wire is connected to the RTN(+) port on the cabling cavity of the RRU External power supply
Bare wire
CPRI optical cable
DLC connector
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU
DLC connector
AISG multi-wire cable
Waterproof DB9 connector Standard AISG female connector
Port labeled RET/PWR_SRXU on the RRU Standard AISG male connector of the AISG extension cable or RCU
18
Installing the DC RRU3004 n
Cable List
Connector Type
Standard AISG male connector
Cable
AISG extension cable
Connected to
Standard AISG female connector of the AISG multi-wire cable
Standard AISG female connector
Standard AISG male connector of the RCU
Interconnect jumper
2W2 connector 2W2 connector
Port labeled RX_IN/OUT on the upper-level RRU Port labeled RX_IN/OUT on the lower-level RRU
Boolean/RS485 input cable
DB15 male connector Eight cord end terminals
Port labeled MON/EXT_ALM in the RRU cabling cavity External alarm devices
19
Installing the DC RRU3004 o
Installing the RRU Cables
1. Opening the Cover Plate of the RRU Cabling Cavity
2. The Cabling Cavity of the RRU
Cabling cavity
Cover plate of the cabling cavity
1. Cable trough for alarm cable 2. Cable trough for the optical cable 3. Cable trough for the optical cable 4. Cable trough for the power cable
Waterproof filler
Reference for making the power cable
20
Installing the DC RRU3004 o
Installing the RRU Cables
3. Cable Connections of RRU
Case 2
Boolean/RS485 input cable
Case 1
CPRI optical cable
Waterproofed alarm cable
Shielding layer of the power cable
Power cable
1. Press the strap on the exposed shielding layer of the power cable tightly. Ensure that the lower edge of the exposed shield layer does not exceed the position shown in the figure. 2. The alarm cable is preferably led out of the RRU from the narrower cable trough in the middle of the cabling cavity. If the cable trough is used by the CPRI optical cable, the alarm cable is led from the wider cable trough near the middle one. In this case, the alarm cable must be wrapped with 10 to 17 layers of waterproof tape so that the diameter of the cable reaches 10 mm to 12 mm. 3. To avoid sharp bending, the optical cable must be pressed by the strap next to the power cable during the optical cable installation. 4. Waterproof fillers should be installed in the unused cable trough.
First wrap the joint with the waterproof tape, and then wrap the joint with the PVC insulating tape.
RF jumper
4. Close the cover plated of the RRU cabling cavity.
1. The tape is wrapped spirally upwards, downwards, and then upwards again in three layers. For every two adjacent tape layers, the tape on the upper layer overlaps about half the width of the tape on the lower layer. 2. Do not remove the dustproof cap from the feeder connectors that are not in use. In addition, protection measures against damp, dust, and salt mist must be taken. If the RRU is installed outdoors, you also need to wrap the joint with waterproof tape.
For details on how to add the OT terminals to the power cable, see page 45.
1. Before fastening the cover plate, check the cables and waterproof fillers and ensure that they are pressed in the corresponding slots. [Link] screw on the cover plate is tightened until the fastening torque is 14 kgfcm. 3. The screws on the cover plate are tightened in the order shown in the preceding figure.
21
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
shielding layer (25 mm)
1.1. RRU+APM30/APM30H
RRU and BBU are on the same site, and the BBU monitors the APM30 or APM30H.
(1) RRU power cable
(2)CPRI optical cable
1. The RRU power cable is connected to one of the LOAD4 to LOAD9 terminals of the PDU. 2. Strip the jacket of the RRU power cable for a small part, press the exposed shielding layer on the strap, and then connect the PGND cable on the strap to the nearest grounding bolt on the side in the APM30/APM30H.
22
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
shielding layer (25 mm)
1.2. RRU+APM30/APM30H
The RRU and BBU are not on the same site, and the RRU monitors the APM30 or APM30H.
X8 X9 X6 X7
(1) RRU power cable
(2)CPRI optical cable
(3) RRU alarm cable
Wire Color of the Alarm Cable Brown White/brown Green White/green
Wire Type Twisted pair
Pins X9 X8
Port on the APMI TX+ TXRX+ RX-
Twisted pair
X7 X6
1. The RRU power cable is connected to one of the LOAD4 to LOAD9 terminals of the PDU. 2. Strip the jacket of the RRU power cable for a small part, press the exposed shielding layer on the strap, and then connect the PGND cable on the strap to the nearest grounding bolt on the side in the APM30/APM30H.
23
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
2. RRU+19-Inch Stand
BBU
DCDU-03B
(1) RRU Power cable
(2) CPRI optical cable
1. The RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B. 2. When connecting the RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 46.
24
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
3. RRU+Wall-Mounted BBU
Shielding layer of RRU power cable
The DCDU panel must face the side and the BBU panel must face downwards.
(1) RRU Power cable
(2) CPRI optical cable
1. The RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B. 2. When connecting the RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 46.
25
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
4. RRU+H-shaped stand +RRU3004 Rack (-48 V power supply )
(1) CPRI optical cable
(2) RRU Power cable
The RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B.
26
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
5. RRU+H-shaped stand+RRU3004 Rack (220 V power supply )
(1) CPRI optical cable
(2) RRU Power cable
The RRU power cable is connected to the OUTPUT RRU terminal of 4815.
27
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
6. RRU+PS4890
(1) RRU Power cable
(2) CPRI optical cable
1. The RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B. 2. When connecting the RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 46.
28
Installing the DC RRU3004 p
RRU Cable Installation Scenarios
7. RRU+TMC
(1) RRU Power cable
(2) CPRI optical cable
1. The RRU power cable is connected to one of the LOAD0 to LOAD5 terminals of the DCDU-03B. 2. When connecting the RRU power cable to the DCDU-03B, you must add an OT terminal to the shielding layer. Then, fix the OT terminal to the corresponding PGND terminal of the DCDU-03B. For details on how to add an OT terminal, see page 46.
29
Installing the AC RRU3004 a
Space Requirements (Unit: mm)
The recommended/minimal clearance for the AC RRU/clearance for Two Combined RRUs is the same as that for the DC RRU. For details, see page 4.
b b
Installation Modes
On a metal pole
On a wall
On an angle steel On a U-steel
On a H-shaped stand
The AC RRU3004 cannot be installed at the side. When it is installed in other modes, the procedure is the same as that of the DC RRU3004. For details, see page 7 to page 11 and page 14 to page 15 .
WARNING 1. The maximum bearing capability of the wall equals four times of the RRU weight, and a single AC RRU3004 weighs 24kg. 2. When the RRU is mounted on the wall, tighten the expansion bolts to 30 Nm. Ensure that the expansion bolts are properly tightened and there is no crack on the wall.
30
Installing the AC RRU3004 c
Installing the Surge Protection Box (for Outdoor Scenarios)
Installation of the surge protection box
Hoop iron the surge protection box
The PG connector of the surge protection box is downward during the installation. Dimensions of the surge protection box (unit: mm) Minimal/Recommended clearance for the surge protection box
Unitmm
31
Installing the AC RRU3004 c
Installing the Surge Protection Box (for Outdoor Scenarios)
1. Install the surge protection box on the metal pole. 1.1. As shown in the figure, unfasten the screw. 1.2. Lead the loop iron through the opening between the back plate of the surge protection box and the surge protection box. 1.3. Circle the loop iron around the metal pole, and then tighten the screw on the loop iron with the torque of 48 kg fcm.
Installing the surge protection box on the wall
If the pole has a small diameter, there is a long extra part of the hoop. It is recommended that the extra part be cut. 2. Open the cover of the surge protection box
1. when installing the surge protection box, you need to dispose of the plastic tube on the expansion bolt. 2. The procedure for installing the surge protection box on the wall is the same as that for installing the RRU on the wall. For details, see page 10.
M4
32
Installing the AC RRU3004 c
Installing the Surge Protection Box (for Outdoor Scenarios)
3. Lead the external AC power cable through the PG connector labeled IN. The L, N, and PE wires of the power cable are connected to the Lin, Nin, and PE terminals on the surge protection box. 4. Lead the power cable between the RRU and the surge protection box through the PG connector labeled OUT. The L, N, and PE wires of the power cable are connected to the Lout, Nout, and PE terminals on the surge protection box. 5. Tighten the PG connector, and then use a wrench to further tighten the connector for one or two laps to ensure its waterproofing capability.
Nout Nin Lout Lin
insulation layer
Install the corrugated pipes for the AC power cables before installing the AC RRU power cables. For details, see page 47.
PG connector
OUT IN
(The cable led through the PG connector labeled OUT is the power cable between the RRU and the surge protection box, and the cable led through the PG connector labeled IN is the external AC power cable.)
6. Close the cover of the surge protection box, and then tighten the screws. (You should tighten the screws in the order shown in the figure with the torque of 14 kg fcm).
M4
33
Installing the AC RRU3004 c
Installing the Surge Protection Box (for Outdoor Scenarios)
7. Connect the PGND cable 1. Connect the external PGND cable between the surge protection box and the grounding point. 2. Connect the PGND cable between the surge protection box and the RRU.
8. Connect the power cable between the surge protection box and the RRU.
AC IN
OUT Install the corrugated pipes for the AC power cables before installing the AC RRU power cables. For details, see page 47.
34
Installing the AC RRU3004 d
Cable Connections of a Single RRU
1. Boolean/RS485 input cable 2. CPRI optical cable 3. Power cable (DC) 4. Equipotential cable 5. Power cable (AC) 6. AISG multi-wire cable [Link] cable [Link] jumper 9. AISG extension cable [Link] [Link] jumper
Antenna
The alarm cable, DC power cable, equipotential cable between the power module and the RRU are installed before delivery.
Sequence of Installing the Cables PGND cable RF jumper Power cable (AC) CPRI optical cable the AISG multi-wire cable and extension cable ( optional )
35
Installing the AC RRU3004 e
Cable Connections of Multiple RRUs
Antenna
Antenna
Antenna
1. CPRI optical cable 3. RF jumper
2. Power cableAC 4. PGND cable
Cable Connections of two Cascaded RRUs
Antenna Antenna
1. CPRI optical cable 2. Power cableAC 3. PGND cable 4. Interconnect jumper 5. RF jumper 6. SFP high-speed cable for cascaded RRUs
36
Installing the AC RRU3004 g
List of Cables (No Surge Protection Box Configured)
Connector Type
OT terminal OT terminal
Cable
PGND cable
Connected to
Grounding bolt on the RRU Nearest grounding bar
RF jumper
DIN male connector DIN male connector
Ports labeled ANT_TX/RXA and ANT_RXB on the RRU Feeder or antenna
External AC input power cable
Round connector to be made depending on field requirements
Port labeled AC IN on the RRU External power supply
CPRI optical cable
DLC connector
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU
DLC connector
AISG multi-wire cable
Waterproof DB9 connector Standard AISG female connector
Port labeled RET/PWR_SRXU on the RRU Standard AISG male connector of the AISG extension cable or RCU
Interconnect jumper
2W2 connector 2W2 connector
Port labeled RX_IN/OUT on the upper-level RRU Port labeled RX_IN/OUT on the lower-level RRU
37
Installing the AC RRU3004 g
List of Cables (No Surge Protection Box Configured)
Connector Type
AISG extension cable
Cable
AISG extension cable
Connected to
Standard AISG female connector of the AISG multi-wire cable
Standard AISG female connector
Standard AISG male connector of the RCU
Interconnect jumper
2W2 connector
Port labeled RX_IN/OUT on the upper-level RRU
2W2 connector
Port labeled RX_IN/OUT on the lower-level RRU
List of Cables (Surge protection box Configured)
Connector Type
OT terminal
Cable
Equipotential cable
Connected to
Grounding bolt on the RRU
OT terminal
Grounding bolt on the surge protection box
PGND cable
OT terminal
Grounding bolt on the surge protection box
OT terminal
Nearest grounding bar
CPRI optical cable
DLC connector
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU
Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the GTMU
DLC connector
38
Installing the AC RRU3004 h
List of Cables (Surge protection box Configured)
Connector Type
DIN male connector
Cable
RF jumper
Connected to
Ports labeled ANT_TX/RXA and ANT_RXB on the RRU
DIN male connector
Feeder or antenna
Power cable between RRU and the surge protection box (the crosssectional area is 1.5 mm2)
Round connector OT terminal
Port labeled AC_in on the RRU The Lout, Nout, and PE terminals on the surge protection box
External AC input power cable(the crosssectional area is 4mm2)
OT terminal To be made depending on field requirements
The Lin, Nin, and PE terminals on the surge protection box External power supply
AISG extension cable
AISG extension cable Standard AISG female connector
Standard AISG female connector of the AISG multi-wire cable Standard AISG male connector of the RCU
Interconnect jumper
2W2 connector 2W2 connector
Port labeled RX_IN/OUT on the upper-level RRU Port labeled RX_IN/OUT on the lower-level RRU
AISG multi-wire cable
Waterproof DB9 connector Standard AISG female connector
Port labeled RET/PWR_SRXU on the RRU Standard AISG male connector of the AISG extension cable or RCU
SFP high-speed cable for cascaded RRUs
SFP200 male connector SFP200 male connector
the CPRI_E port on upper-level the RRU the CPRI_W port on the lower-level RRU
39
Installing the AC RRU3004 i
Installing the RRU Cables
The cabling cavity of the AC RRU3004 is the same as that of the DC RRU3004 The procedures for opening and closing the cover for the cabling cavity of the AC RRU3004 are the same as those for opening and closing the cover for the cabling cavity of the DC RRU3004.
Boolean/RS485 input cable CPRI optical cable Power cable(DC) Equipotential cable Power cable(AC) PGND cable RF jumper
40
Installing the AC RRU3004 i
Installing the RRU Cables
for Outdoor Scenarios
1. CPRI optical cable 2. Equipotential cable 3. PGND cable 4. Power cable between RRU and the surge protection box 5. External AC input power cable
1 2 3 5
for Indoor Scenarios
1. CPRI optical cable 2. PGND cable 3. External AC input power cable
2 1
The maximum length of the external AC input power cable is 100 m for both the 110 V AC single-phase power cable or 220 V AC single-phase power cable.
41
Installing the AC RRU3004 j i
Installation Checklist
1. The PG connectors labeled IN and OUT on the surge protection box are securely installed and cannot be rotated with the cables. 2. The waterproof gaskets on the door of the cabling cavity of the surge protection box are not stripped or broken. 3. The OT terminals of the cables connected to the surge protection box are securely linked. The jackets of the cables are not damaged, and there are no uneven edges on the cables. 4. The PG connectors are tightened, and the waterproof rings are secure. 5. The six screws on the cabling cavity of the surge protection are tightened according to the required fastening torque. 6. The axis for the door of the cabling cavity of the surge protection box is not broken, and the surface of the protection box is not scratched. 7. The cables in the surge protection box are correctly connected by referring to the operation guide. The OT terminals are tight linked before the door of the cabling cavity is closed. 8. The power supply to the surge protection box is cut off before installation and maintenance. 9. The installation and maintenance of the surge protection box is not performed in rainy or damp weather.
42
Powering On the RRU
Start
Power on the RRU
Rectify the fault
Check whether the status of the RUN LED is 1s ON, 1s OFF and that of ALM LED is OFF.
No
When the RRU is unpacked, it must be powered on within 24 hours. Each time the RRU is maintained after being put into use, the power-off duration cannot exceed 24 hours.
Yes End
Reference a
Binding the RRU and Installation Components
1. Bind the RRU by leading the lifting rope along the lower part of the adapting piece and through the handle, bind the main and auxiliary brackets with the lifting rope, and then bind the steering rope with the handle of the RRU, as shown in the following figures.
Lifting Rope
Steering rope
Do not bind the lifting rope only on the handle when lifting the RRU.
1. When lifting the RRU and installation components to the tower, prevent the RRU from colliding with the tower. 2. The cross-sectional area of the lifting rope and steering rope is around 20 mm, not more than 25 mm. In addition, the ropes can bear the weight four times more than that of the RRU.
43
Reference a
Binding the RRU and Installation Components
2. Lifting the RRU and Installation Components to the Tower
2.1. Installers A climb onto the tower. Then, installer A fixes the pulley to the support of the tower platform and leads the lifting rope through the pulley. 2.2. Installer C uses a lifting rope to bind the RRU and installation components as shown in the preceding figure and then tie a knot in the steering rope at the handle of the RRU. 2.3. Installer B pulls the lifting rope, and at the same time, installer C pulls the steering rope away from the tower to prevent the RRU and installation components from colliding with the tower. 2.4. Installers A hold the RRU and installation components and untie the ropes. Pulley
Lifting rope
Steering rope
3. Lifting the CPRI Optical Cable up to the Tower
3.1. Cut off a 200 mm long corrugated pipe with the diameter of 25 mm. 3.2. Lead the fiber tails labeled 1A and 1B of the optical cable into the corrugated pipe by 160 mm. 3.3. Wrap up the corrugated pipe and optical cable with the color tape. 3.4. For the tower made of steel pipes, tie the black jacket to the corrugated pipe at the position 150 mm away from the color tape, and then lift the optical cable up to the tower. 3.5. For the tower made of angle steel girders, carry the optical cable onto the tower when climbing up to the tower. 3.6. After the optical cable is lifted up to the tower, remove the color tape and corrugated pipe before installing the optical cable.
Corrugated pipe Color tape
44
Reference b
Making OT Terminals by Using a Cable Peeler (Recommended)
Add two OT terminals to the end of the power cable connecting to the RRU. -48V DC power wire
-48V DC power cable
OT terminals
GND wire Shielding layer
Determine lengths of power cables for different operations according to the scales on the inner side of the cover plate of the cabling cavity.
Based on the determined length, remove the jacket and shielding layer off the power cable.
Remove the jacket from each wire.
Add an OT terminal to each wire.
Strip a 15 mm jacket off the power cable to reveal the shielding layer of the power cable
The assembling of OT terminals to the power cable must be complete before the RRU is installed on a metal pole.
45
Reference c
Making OT Terminals at the Input End of the Power Cable by Using a Knife
Lead the wires with shielding layers through heat-shrinkable tubes
Wrap the PVC insulating tape at the conjunction where the three wires meet
OT terminal on shielding layer
the
WARNING Do not damage the shielding layer of the power cable when cutting around the jacket.
46
Reference d
Installing the corrugated pipes of AC power cable
1. After the corrugated pipe is installed, wrap both ends of the power cable with waterproof tapes by referring to the following figure. 2. Wrap the joint spirally upward, downward, and then upward again. That is, the joint is wrapped by three layers of the tape. Ensure that two adjacent layers overlap with each other about half the width of the tape.
Waterproof tapes
Connector for corrugated pipes
Power system
Corrugated pipes
Pin Assignment for the Wires of the RRU Alarm Cable ( DC )
Signal name of DB15 connector
SWITCH_INPUT0+ GND SWITCH_INPUT1+ GND RX485_TXRX485_TX+ RX485_RXRX485_RX+
DB15 connector
X1.2 X1.3 X1.6 X1.7 X1.10 X1.11 X1.13 X1.14
Cord End Terminal
X2 X3 X4 X5 X6 X7 X8 X9
Wire Color
White/blue Blue White/orange Orange White/ green Green White/ brown Brown
Wire Type
Twisted pair
Label
SWITCH_INPUT0+ GND
Twisted pair
SWITCH_INPUT1+ GND
Twisted pair
APM RXAPM RX+
Twisted pair
APM TXAPM TX+
47
Changes in the RRU3004 Installation Guide
This describes the changes in the RRU3004 Installation Guide. 042009-07-15) This is the fourth commercial release. Compared with issue 03 (2009-04-20) of V300R008, no contents are added, deleted.
48
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base Bantian Longgang Shenzhen 518129 Peoples Republic of China [Link]