Magnecraft Latching Relay Wiring
Detailed wiring descriptions and diagrams
Wiring Diagrams Contacts Open
Reset Impulse Voltage
Wire Setup
2-Wire, Unidirectional Pulse: The contacts transfer and reset when a unidirectional pulse is applied to the single coil using two (2) control wires. Available for AC & DC circuits.
Control Wires
Contacts Closed
Initial Impulse Voltage
Relays
Coil #1
Latching Relay (Top View)
Control Wires
Latching Relay (Top View)
Coil #1
711
Relay Contacts Closed Output Voltage Load
Relay Contacts Open Output Voltage
Load
2-Wire, Alternating Polarity: The contacts transfer and reset when the voltage polarity is alternated into the single coil using two (2) control wires. Available for DC circuits only.
Control Wires
Latching Relay (Top View)
Reset Impulse Voltage
Initial Impulse Voltage
Coil #1
Control Wires
Latching Relay (Top View)
Coil #1
303 785
Load
Relay Contacts Open Output Voltage
Load
Relay Contacts Closed Output Voltage
3-Wire: The contacts transfer and reset when the voltage is alternated between two (2) control wires while utilizing a third (common) wire. This single coil has internal diodes. Available for AC circuits only.
Control Wires
Latching Relay (Top View)
Reset Impulse Voltage
Coil #1
Control Wires
Latching Relay (Top View)
Initial Impulse Voltage
Coil #1
Relay Contacts Open Output Voltage
Load
Relay Contacts Closed Output Voltage
Load
303 755 785
4-Wire: The contacts transfer and reset when the voltage is alternated between two (2) unique coils using four (4) control wires. Available for DC circuits only.
Control Wires
Latching Relay (Top View)
Reset Impulse Voltage
Coil #1
Coil #2
Control Wires
Latching Relay (Top View)
Initial Impulse Voltage
Coil #1
Coil #2
Relay Contacts Open Output Voltage
Load
Relay Contacts Closed Output Voltage
Load
303 385 755 785