0% found this document useful (0 votes)
400 views

Load Test On DC Compound

The document summarizes a load test performed on a DC compound motor to determine its performance characteristics. Various meters were connected to measure voltage, current, speed and torque at increasing levels of load. Readings were taken at each load step until the rated current was reached. Calculations were done to determine input power, output power, torque and efficiency. A table with results at each step was included to show the motor's performance under varying loads. The aim of drawing the motor's performance characteristics was achieved through this load testing.

Uploaded by

kiran_y2
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
400 views

Load Test On DC Compound

The document summarizes a load test performed on a DC compound motor to determine its performance characteristics. Various meters were connected to measure voltage, current, speed and torque at increasing levels of load. Readings were taken at each load step until the rated current was reached. Calculations were done to determine input power, output power, torque and efficiency. A table with results at each step was included to show the motor's performance under varying loads. The aim of drawing the motor's performance characteristics was achieved through this load testing.

Uploaded by

kiran_y2
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

LOAD TEST ON D.C.

COMPOUND MOTOR

AIM To draw the performance characteristics of DC compound motor by conducting load test.

APPARATUS REQUIRED:Sl. No. 1. 2. 3. 4. 5. Name of the Apparatus Ammeter Voltmeter Rheostat Tachometer Ammeter Range (0 - 20A) (0 - 300V) 200, 2 A (0 -10000rpm) (0 - 2A) Type MC MC Digital MC Quantity

1 1 1 1 1

PROCEDURE The connections are given as per the circuit diagram. The DPST switch is closed. The motor is started using the four point starter. The speed of the motor is adjusted to the rated value by varying the field rheostat. The no load readings are noted. The load on the brake drum increased in steps. At each step of loading the meter readings are noted. The procedure is repeated till the ammeter reads the rated current.

PRECUATION All the switches are kept open initially. The field rheostat should be kept a minimum resistance position. There should not be any load when start and stop the motor.

MODEL CALCULATION:-

Circumference of brake drum = 2 x x R in meter R Radius of the brake drum Torque, T = (S1 S2) x 9.81 x R in Nm Input power, Pi = VL x IL in Watts Output power, Pm = (2 x x N x T) / 60 % Efficiency, = (Pm / Pi) x 100 in Watts

TABULAR COLOUMN Sl. No. Voltage, VL (V) Current IL (A) Spring balance S1 Kg S2 Kg Speed Rpm Torque N-m Input Pi watts Output Pm watts Efficiency In %

RESULT Thus the performance characteristics of the DC compound motor were drawn.