0% found this document useful (0 votes)
87 views1 page

Features : Notes

The document describes an optical smoke detector that uses a light emitting diode and photocell to detect smoke particles. It operates on 12VDC, has normal open and normal close relay outputs, and includes an LED that remains lit until a button is pressed after an alarm. Specifications include standby and alarm currents, operating temperature and humidity ranges, dimensions, weight and maximum input voltage.

Uploaded by

Careto
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views1 page

Features : Notes

The document describes an optical smoke detector that uses a light emitting diode and photocell to detect smoke particles. It operates on 12VDC, has normal open and normal close relay outputs, and includes an LED that remains lit until a button is pressed after an alarm. Specifications include standby and alarm currents, operating temperature and humidity ranges, dimensions, weight and maximum input voltage.

Uploaded by

Careto
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 1

Features

1.12VDC input power, can be combined with security / burglar system 2. N/C (normal/close); N/O (normal/open) selected relay output 3. With a button on the surface, when the detector alarms, the LED signal will hold until press the button.

Sensing way
Optical(Photoelectric )smoke detector responds to smoke. It has a chamber inside consists of a light-emitting diode (LED) that constantly shoots a beam of light and a photocell that senses light from darkness. In peacetime, the photocellcan not senses the beam of light form the lightemitting diode (LED). When there is smoke into the chamber of detector ,the beam of light is scattered by smoke particles, and the scattered light hit thephotocell, thus the alarm is initiated.

Specifications
Model No Input voltage Standby current Alarm current Suitable temperature Suitable humidity Size Weight Provide the outside with the maximum value of signal input joint volume HC-206B Optical Smoke Detector 12VDC 90A 60mA -15~50 C 0~95% RH 103mm x 43mm 1520g DC-30V 1A Material Joint contact Color Overall structure Fire-resisting ABS material Copper (zinc-plated) Ivory

Notes Prohibit from being installed at the places with large volume of smoke and steam lingering, and the inlet and outlet of cold and warm air.

General wiring drawing

*The red wires are power source (12VDC) *The black wires are the signal source. *N/O type, point 3 and point 4 do not connect in peacetime, when alarm, point 3 and point 4 will be connected. *N/C type, point 3 and point 4 connected in peacetime, when alarm, point 3 and point 4 will be unconnected.