TSO Commands
Message-id = MSGID
Displays the Message-id of the last message. o o o o Automatic REFLIST can be accessed by REFLISTD REFLISTL REFACTD REFACTL
These allow you to pull back datasets without seeing the intermediate lists. Commands to quickly add names to your personal lists. These are REFOPEND, REFOPENL, REFADDD, and REFADDL
RETP View the stack of your typed commands. RETF Pull back commands in reverse order. RETRIEVE Pop up the most recent typed commands from the stack. CRETRIEV Pop up the most recent typed commands from the stack. ISRDDN Shows the current data sets allocation for our ISPF session. XMIT
The TSO/E Interactive Data Transmission Facility TRANSMIT command allows you to send data sets or messages to persons on other MVS systems via Network Job Entry or directly to persons on your own system. XMIT node.userid DA(your.pds) OUTDA(your.ps)
RECEIVE
The TSO/E Interactive Data Transmission Facility RECEIVE command allows you to obtain files transmitted to your userid. The RECEIVE command queries the Job Entry Subsystem RECEIVE INDS(your xmi.ps)
QPRINT
TSO PROFILE
The profile command is used either to specify to the system certain user characteristics which are to be used to control the flow of information to and from the terminal or to list the user profile. The user profile is retained throughout each terminal session unless the user wishes to change it by issuing the profile command again and specifying the appropriate operands.
CUT DISPLAY
This command when given while a member is opened in view/edit mode will show the Clipboard manager. The Clipboard can then be browsed or deleted.
KEYS
If the KEYLIST is ON, it displays the keys of current Keylist. If the KEYLIST is OFF, it displays the Primary keys definition.
PFSHOW OFF
Displays the value of all the PFKEYS on the panel. They can be removed from the panel by invoking PFSHOW
SCRNAME ON
Displays the screen name of the Top Left corner. We can give our own screen name to any screen by writing SCRNAME myscrname
SWAP LIST
ASM
CALC
COBOL
FORT
CALL
LINK
LOADGO
RUN
TEST
TESTAUTH
ALLOCATE
ALTLIB
DEFINE OPTIONAL, USER-LEVEL OR APPLICATION-LEVEL SETS OF LIBRARIES CONTAINING SAA/PL EXECS OR CLISTS. THESE LIBRARIES ARE SEARCHED WHEN IMPLICITLY INVOKING AN SAA/PL EXEC OR CLIST.
ATTRIB
ALLOW DCB PARAMETERS TO BE DYNAMICALLY INTRODUCED AND NAMED FOR USE WITH A SUBSEQUENT ALLOCATE COM.
CONVERT
COPY
DELETE
EDIT
FORMAT
FREE
LIST
LISTALC
LISTBC
LISTCAT
LISTDS
MERGE
PRINTDS
PROTECT
RENAME
TSOLIB
DEFINE OPTIONAL SEARCH LEVEL THAT TSO/E USES WHEN SEARCHING FOR COMMANDS AND PROGRAMS.
ACCOUNT
CONSOLE
OPERATOR
PARMLIB
RACONVRT
SYNC
SYNCHRONIZE THE BROADCAST DATA SET WITH USER IDS FROM THE UADS AND RACF DATA BASE.
SESSION CONTROL
CONSPROF
EXEC
EXECUTIL
HELP
LOGOFF
LOGON
PROFILE
SEND
TERMINAL
TIME
TSOEXEC
WHEN
CANCEL
OUTPUT
STATUS
SUBMIT
INTERACTIVE
RECEIVE
TRANSMIT
COBOL Tutorial
Computer Programming
A Program is a set of instructions that enables a computer to process data, there are two types of computer programs which are 1- Operating system programs, which control the overall operation of the system and 2- Applications programs, it is the actual program tasks required by the users. The term used to describe all type of programs is called software in general application program reads input , process it, and produce information or out put the user neads. A set of computerized business procedures in an application area is called information systems.
History of Cobol.
Developed by 1959 by a group called COnference on Data Systems Language (CODASYL). First COBOL compiler was released by December 1959.
First ANSI approved version Modified ANSI approved version Modified ANSI approved version
Interduction to Cobol
COBOL is a high-level programming language first developed by the CODASYL Committee (Conference on Data Systems Languages) in 1960. Since then, responsibility for developing new COBOL standards has been assumed by the American National Standards Institute (ANSI). The word COBOL is an acronym that stands for COmmon Business Oriented Language. As the the expanded acronym indicates, COBOL is designed for developing business, typically file-oriented, applications. It is not designed for writing systems programs. For instance you would not develop an operating system or a compiler using COBOL
Coding Sheet.
1-6 7 8-11 12-72 73-80 Page/line numbers Optional (automatically assigned by compiler) Continuity (-), Comment (*), Starting a new page (/), Debugging lines (D) Column A -Division, Section, Paragraph, 01,77 declarations must begin here. Column B -All the other declarations/statements begin here. Identification field. It will be ignored by the compiler but visible in the source listing.
Language Structure.
Character Set Word Clause Statement Sentence Paragraph Section Division Program :::::::::Digits (0-9), Alphabets (A-Z), Space (b), Special Characters (+ * / ( ) = $ ; > < . ,) One or more characters- User defined or Reserved. One or more words. It specifies an attribute for an entry. One or more valid words and clauses. One or more statements terminated by a period. One or more sentences. One or more paragraphs. One or more sections or paragraphs. Made up of four divisions.
Divisions in COBOL.
There are four divisions in a COBOL program and Data division is optional.
1. 2. 3. 4.
Identification Division.
This is the first division and the program is identified here. Paragraph PROGRAM-ID followed by user-defined name is mandatory. All other paragraphs are optional and used for documentation. The length of user-defined name for IBM COBOL is EIGHT.
IDENTIFICATION DIVISION.
PROGRAM NAME. COMMENT ENTRY. COMMENT ENTRY. COMMENT ENTRY. COMMENT ENTRY. COMMENT ENTRY.
Security does not pertain to the operating system security, but the information that is passed to the user of the program about the security features of the program.
Environment Division.
Only machine dependant division of COBOL program. It supplies information about the hardware or computer equipment to be used on the program. When your program moves from one computer to another computer, the only section that may need to be changed is ENVIRONMENT division.
It supplies information concerning the computer on which the program will be compiled (SOURCE-COMPUTER) and executed (OBJECT-COMPUTER). It consists of three paragraphs SOURCE COMPUTER, OBJECT-COMPUTER and SPECIAL-NAMES. This is OPTIONAL section from COBOL 85. SOURCECOMPUTER. IBM-4381 (Computer and model # supplied by manufacturer) WITH DEBUGGING MODE clause specifies that the debugging lines in the program (statements coded with D in column 7) are compiled.
Configuration Section.
OBJECTCOMPUTER.
SPECIALNAMES.
This paragraph is used to relate hardware names to user-specified mnemonic names. 1. Substitute character for currency sign. (CURRENCY SIGN IS litearal-1) 2. Comma can be used as decimal point. (DECIMAL-POINT IS COMMA) 3. Default collating sequence can be changed. It will be explained later . 4. New class can be defined using CLASS keyword. (CLASS DIGIT is 0 thru 9)
It contains information regarding the files to be used in the program and it consists of two paragraphs FILE-CONTROL & I-O CONTROL. FILE CONTROL. I-O CONTROL. Files used in the program are identified in this paragraph.
Input-Output Section.
It specifies when check points to be taken and storage areas that are shared by different files.
Data Division.
Data division is used to define the data that need to be accessed by the program. It has three sections.
describes the record structure of the files. is used to for define intermediate variables. is used to access the external data. Ex: Data passed from other programs or from PARM of JCL.
Declaration of variable
Level# $ {Variable/Filler} $ Picture clause $ Value clause $ Usage Clause $ Sync clause.
Level#
It specifies the hierarchy of data within a record. It can take a value from the set of integers between 01-49 or from one of the special level-numbers 66 77 88
:::::-
Specifies the record itself. It may be either a group item or an Elementary item. It must begin in Area A. Specify group or elementary items within a record. Group level items must not have picture clause. Identify the items that contain the RENAMES clause. Identify independent data item. Condition names.
FILLER
When the program is not intended to use selected fields in a record structure, define them as FILLER. FILLER items cannot be initialized or used in any operation of the procedure division.
PICTURE Clause
Describes the attributes of variable.
9 (Digit), V (Implied decimal point), S (Sign) + (Plus Sign), (Minus Sign), CR DB (Credit Debit Sign), . (Period), b (Blank), ,(comma), 0 (Zero), / (Slash) BLANK WHEN ZERO (Insert blank when data value is 0), Z (ZERO suppression), * (ASTERISK), $(Currency Sign) A (alphabet), B (Blank insertion Character), X(Alpha numeric), G(DBCS) 1. + CR DB V . $ + Z * (But $ Can appear as first place and * as floating. $***.**)
Exclusive sets
2. 3.
DBCS (Double Byte Character Set) is used in the applications that support large character sets. 16 bits are used for one character. Ex: Japanese language applications.
Refreshing Basics
Nibble Byte Half word Full word Double word
Usage Clause
:::::-
4 Bits is one nibble. In packed decimal, each nibble stores one digit. 8 Bits is one byte. By default, every character is stored in one byte. 16 bits or 2 bytes is one half word. (MVS) 32 bits or 4 bytes is one full word. (MVS) 64 bits or 8 bytes is one double word. (MVS)
DISPLAY
:-
Default. Number of bytes required equals to the size of the data item. Binary representation of data item. PIC clause can contain S and 9 only. S9(01) S9(04) Half word. Full word. Double word.
COMP
:-
Most significant bit is ON if the number is negative. COMP-1 COMP-2 COMP-3 INDEX ::::Single word floating point item. PIC Clause should not be specified. Double word floating-point item. PIC Clause should not be specified. Packed Decimal representation. Two digits are stored in each byte. Last nibble is for sign. (F for unsigned positive, C for signed positive and D for signed negative) Formula for Bytes: Integer ((n/2) + 1)) => n is number of 9s. It is used for preserve the index value of an array. PIC Clause should not be specified.
VALUE Clause
It is used for initializing data items in the working storage section. Value of item must not exceed picture size. It cannot be specified for the items whose size is variable.
Syntax:
VALUE IS literal. VALUES ARE literal-1 THRU | THROUGH literal-2 VALUES ARE literal-1, literal-2
Literal can be numeric without quotes OR non-numeric within quotes OR figurative constant.
SIGN Clause
Syntax SIGN IS (LEADING) SEPARATE CHARACTER (TRAILING). It is applicable when the picture string contain S. Default is TRAILING WITH NO SEPARATE CHARACTER. So S doesnt take any space. It is stored along with last digit. +1=A, +2=B, +3=C, +4=D, +5=E, +6=F, +7=G, +8=H, +9=I, -0=}, -1= J, -2= K, -3=L, -4=M, -5=N, -6=O, -7=P, -8=Q, -9=R
REDEFINES
The REDEFINES clause allows you to use different data description entries to describe the same computer storage area. Redefining declaration should immediately follow the redefined item and should be done at the same level. Multiple redefinitions are possible. Size of redefined and redefining need not be the same. Example:
01 01
WS-DATE WS-REDEF-DATE 05 05 05
RENAMES
It is used for regrouping of elementary data items in a record. It should be declared at 66 level. It need not immediately follows the data item, which is being renamed. But all RENAMES entries associated with one logical record must immediately follow that records last data description entry. RENAMES cannot be done for a 01, 77, 88 or another 66 entry.
01 05 05 66
CONDITION name
It is identified with special level 88. A condition name specifies the value that a field can contain and used as abbreviat ion in condition checking.
01 88 88
IF SEX=1 can also be coded as IF MALE in Procedure division. SET FEMALE TO TRUE moves value 2 to SEX. If multiple values are coded on VALUE clause, the first value will be moved when it is set to true.
JUSTIFIED RIGHT
This clause can be specified with alphanumeric and alphabetic items for right justification. It cannot be used with 66 and 88 level items.
OCCURS Clause
OCCURS Clause is used to allocate physically contiguous memory locations to store the table values and access them with subscript or index. Detail explanation is given in Table Handling section.
LINKAGE SECTION
It is used to access the data that are external to the program. JCL can send maximum 100 characters to a program thru PARM. Linkage section MUST be coded with a half word binary field, prior to actual field. If length field is not coded, the first two bytes of the field coded in the linkage section will be filled with length and so there are chances of 2 bytes data truncation in the actual field.
01 05 05
Procedure Division.
This is the last division and business logic is coded here. It has user-defined sections and paragraphs. Section name should be unique within the program and paragraph name should be unique within the section. Procedure division statements are broadly classified into following categories.
Statement Type Imperative Conditional Compiler Directive Explicit Scope terminator Implicit Scope terminator
Meaning Direct the program to take a specific action. Ex: MOVE ADD EXIT GO TO Decide the truth or false of relational condition and based on it, execute different paths . Ex: IF, EVALUATE Directs the compiler to take specific action during compilation. Ex: COPY SKIP EJECT Terminate the scope of conditional and imperative statements. Ex: END-ADD END-IF END-EVALUATE The period at the end of any sentence, terminates the scope of all previous statements not yet terminated.
MOVE Statement
It is used to transfer data between internal storage areas defined in either file section or working storage section.
Syntax: MOVE identifier1/literal1/figurative-constant TO identifier2 (identifier3) Multiple move statements can be separated using comma, semicolons, blanks or the keyword THEN.
Picture of A PIC 99V99 PIC 99V99 PIC99V999 PIC9(05)V9(03) PIC9(04)V9(02) PIC99V99 PICX(04)
Picture of B PIC 999V99 PIC 9999V9999 PIC9V99 PIC 9(03)V9(03) PICZZZ99.9 PIC$$$.99 XBXBXB
Value of B after Move 012.35 0012.3500 2.34 321.543 23.2 $.34 MUS
ARITHMETIC VERBS
All the possible arithmetic operations in COBOL using ADD, SUBTRACT, MULTIPLY and DIVIDE are given below:
Arithmetic Operation ADD A TO B ADD A B C TO D ADD A B C GIVING D ADD A TO B C SUBTRACT A FROM B SUBTRACT A B FROM C SUBTRACT A B FROM C GIVING D MULTIPLY A BY B
A A A A A A A A A
C C A+C
A+B+C+D A+B+C
C-(A+B) C C-(A+B)
MULTIPLY A BY B GIVING C DIVIDE A INTO B DIVIDE A INTO B GIVING C DIVIDE A BY B GIVING C DIVIDE A INTO B GIVING C REMAINDER D
A A A A A
B B/A B B B
A*B
GIVING is used in the following cases: 1.To retain the values of operands participating in the operation. 2.The resultant value of operation exceeds any of the operand size.
ROUNDED option
With ROUNDED option, the computer will always round the result to the PICTURE clause specification of the receiving field. It is usually coded after the field to be rounded. It is prefixed with REMAINDER keyword ONLY in DIVIDE operation. ADD A B GIVING C ROUNDED. Caution: Dont use for intermediate computation.
ON SIZE ERROR
If A=20 (PIC 9(02)) and B=90 (PIC 9(02)), ADD A TO B will result 10 in B where the expected value in B is 110. ON SIZE ERROR clause is coded to trap such size errors in arithmetic operation. If this is coded with arithmetic statement, any operation that ended with SIZE error will not be carried out but the statement follows ON SIZE ERROR will be executed. ADD A TO B ON SIZE ERROR DISPLAY ERROR!.
COMPUTE
Complex arithmetic operations can be carried out using COMPUTE statement. We can use arithmetic symbols than keywords and so it is simple and easy to code. + For ADD, for SUBTRACT, * for MULTIPLY, / for DIVIDE and ** for exponentiation. Rule: Left to right 1.Parentheses 2.Exponentiation 3.Multiplication and Division 4.Addition and Subtraction Caution: When ROUNDED is coded with COMPUTE, some compiler will do rounding for every arithmetic operation and so the final result would not be precise. 77 A PIC 999 VALUE 10 COMPUTE A ROUNDED = (A+2.95) *10.99 Result: (ROUNDED(ROUNDED(12.95) * ROUNDED(10.99)) =120 or ROUNDED(142.3205) = 142 So the result can be 120 or 142. Be cautious when using ROUNDED keyword with COMPUTE statement. All arithmetic operators have their own explicit scope terminators. (END-ADD, END-SUBTRACT, END-MULTIPLY, ENDDIVIDE, END-COMPUTE). It is suggested to use them. CORRESPONDING is available for ADD and SUBTRACT only.
INITIALIZE
VALUE clause is used to initialize the data items in the working storage section whereas INITIALIZE is used to initialize the data items in the procedure division. INITIALIZE sets the alphabetic, alphanumeric and alphanumeric-edited items to SPACES and numeric and numeric-edited items to ZERO. This can be overridden by REPLACING option of INITIALIZE. FILLER, OCCURS DEPENDING ON items are not affected.
Syntax:
ACCEPT
ACCEPT can transfer data from input device or system information contain in the reserved data items like DATE, TIME, DAY. ACCEPT WS-VAR1 (FROM DATE/TIME/DAY/OTHER SYSTEM VARS). If FROM Clause is not coded, then the data is read from terminal. At the time of execution, batch program will ABEND if
there is no in-stream data from JCL and there is no FROM clause in the ACCEPT clause. DATE option returns six digit current date in YYYYMMDD DAY returns 5 digit current date in YYDDD TIME returns 8 digit RUN TIME in HHMMSSTT DAY-OF-WEEK returns single digit whose value can be 1-7 (Monday-Sunday respectively)
DISPLAY
It is used to display data. By default display messages are routed to SYSOUT. Syntax: DISPLAY identifier1| literal1 (UPON mnemonic name)
Collating Sequence
There are two famous Collating Sequence available in computers. IBM and IBM Compatible machine use EBCDIC collating sequence whereas most micro and many mainframe systems use ASCII collating sequence. The result of arithmetic and alphabetic comparison would be same in both collating sequences whereas the same is not true for alphanumeric comparison
Default collating sequence can be overridden by an entry in OBJECT-COMPUTER and SPECIAL NAMES paragraphs. 1. Code the PROGRAM COLLATING SEQUENCE Clause in the Object computer paragraph. PROGRAM COLLATING SEQUENCE IS alphabet-name 2. Map the alphabet-name in the SPECIAL-NAMES paragraph as follows: ALPHABET alphabet-name is STANDARD-1 | NATIVE NATIVE stands for computers own collating sequence whereas STANDARD -1 stands for ASCII collating sequence.
IF/THEN/ELSE/END-IF
The most famous decision making statement in all language is IF. The syntax of IF statement is given below: IF can be coded without any ELSE statement. THEN is a noise word and it is optional. If ORs & ANDs are used in the same sentence, ANDs are evaluated first from left to right, followed by ORs. This rule can be overridden by using parentheses. The permitted relation conditions are =, <, >, <=, >=, <> CONTINUE is no operation statement. The control is just passed to next STATEMENT. NEXT SENTENCE passes the control to the next SENTENCE. If you forgot the difference between statement and sentence, refer the first page. It is advised to use END-IF, explicit scope terminator for the IF statements than period, implicit scope terminator. IF condition1 AND condition2 THEN Statement-Block-1 ELSE IF condition3 THEN CONTINUE ELSE IF condition4 THEN Statement-Block-2 ELSE NEXT SENTENCE
END-IF END-IF END-IF Statement-Block-2 will be executed only when condition 1, 2 and 4 are TRUE and condition 3 is FALSE. Implied operand: In compound conditions, it is not always necessary to specify both operands for each condition. IF TOTAL=7 or 8 is acceptable. Here TOTAL=8 is implied operation.
EVALUATE
With COBOL85, we use the EVALUATE verb to implement the case structure of other languages. Multiple IF statements can be efficiently and effectively replaced with EVALUATE statement. After the execution of one of the when clauses, the control is automatically come to the next statement after the END-EVALUATE. Any complex condition can be given in the WHEN clause. Break statement is not needed, as it is so in other languages. General Syntax
EVALUATE
subject-1 (ALSO subject2..) WHEN object-1 (ALSO object2..) WHEN object-3 (ALSO object4..) WHEN OTHER imperative statement
END-EVALUATE.
1.Number of Subjects in EVALUATE clause should be equal to number of objects in every WHEN clause. 2.Subject can be variable, expression or the keyword TRUE/ FLASE and respectively objects can be values, TRUE/FALSE or any condition. 3.If none of the WHEN condition is satisfied, then WHEN OTHER path will be executed. Sample
EVALUATE
SQLCODE ALSO TRUE WHEN 100 ALSO A=B imperative statement WHEN -305 ALSO (A/C=4) imperative statement WHEN OTHER imperative statement
END-EVALUATE.
PERFORM STATEMENTS
PERFORM will be useful when you want to execute a set of statements in multiple places of the program. Write all the statements in one paragraph and invoke it using PERFORM wherever needed. Once the paragraph is executed, the control comes back to next statement following the PERFORM.
1.SIMPLE PERFORM.
PERFORM PARA-1. DISPLAY PARA-1 executed STOP RUN. PARA-1. Statement1. Statement2.
It executes all the instructions coded in PARA-1 and then transfers the control to the next instruction in sequence.
2.INLINE PERFORM.
When sets of statements are used only in one place then we can group all of them within PERFORM END-PERFORM structure. This is called INLINE PERFORM. This is equal to DO..END structure of other languages.
Initialize identifier1 with identifier2 and test the condition(s). If the condition is false execute the statements in PARA-1 thru PARA-N and increment identifier1 BY identifier3 and check the condition(s) again. If the condition is again false, repeat this process till the condition is satisfied.
EXIT statement.
COBOL reserved word that performs NOTHING. It is used as a single statement in a paragraph that indicate the end of paragraph(s) execution. EXIT must be the only statement in a paragraph in COBOL74 whereas it can be used with other statements in COBOL85.
GO TO Usage:
In a structured top-down programming GO TO is not preferable. It offers permanent control transfer to another paragraph and the chances of logic errors is much greater with GO TO than PERFORM. The readability of the program will also be badly affected. But still GO TO can be used within the paragraphs being performed. i.e. When using the THRU option of PERFORM statement, branches or GO TO statements, are permitted as long as they are within the range of named paragraphs.
PERFORM 100-STEP-1.
Here GO TO used within the range of PERFORM. This kind of Controlled GO TO is fine with structured programming also!
ADD A TO B GIVING C.
IF D = ZERO DISPLAY MULTIPLICATION NOT DONE An OCCURS clause is used to GO TO 300-STEP3 END-IF. 200-STEP-2. MULTIPLY C BY D. 300-STEP-3. DISPLAY VALUE OF C: C.
indicate the repeated occurrences of items of the same format in a structure. OCCURS clause is not valid for 01, 77, 88 levels. It can be defined as elementary or group item. Initialization of large table occurrences with specific values are usually done using perform loops in procedure division. Simple tables can be initialized in the following way.
TABLES
0 1
0 5
Dynamic array is the array whose size is decided during runtime just before the access of first element of the array.
01 05
IF MONTH = FEB MOVE 28 to WS-OCCURRENCE. Array Items can be accessed using INDEX or subscript and the difference between them are listed in the table. Relative subscripts and relative indexes are supported only in COBOL85. Literals used in relative subscripting/indexing must be an
Sl # 1 2
Subscript
Index
Working Storage item It means occurrence Occurrence, in turn translated to displacement to access elements and so slower than INDEX access.
It cannot be used for arithmetic operation or for display purpose. INDEX can only be modified with SET, SEARCH and PERFORM statements.
Sometimes, you may face a question like how to randomly access the information in the sequential file of 50 records that contains all the designation and the respective lower and higher salary information. Obviously, OS does not allow you to randomly access the sequence file. You have to do by yourself and the best way is, load the file into a working storage table in the first section of the program and then access as you wish. The table look-up can be done in two ways. -Sequential search. -Binary search.
Sequential SEARCH
During SERIAL SEARCH, the first entry of the table is searched. If the condition is met, the table look-up is completed. If the condition is not met, then index or subscript is incremented by one and the next entry is searched and the process continues until a match is found or the table has been completely searched. SET indexname-1 TO 1. SEARCH identifier-1 AT END display match not found: WHEN condition-1 imperative statement-1 /NEXT SENTENCE WHEN condition-2 imperative statement-2 /NEXT SENTENCE END-SEARCH Identifier-1 should be OCCURS item and not 01 item. Condition-1, Condition-2 compares an input field or search argument with a table argument. Though AT END Clause is optional, it is highly recommended to code that. Because if it is not coded and element looking for is not found, then the control simply comes to the next statement after SEARCH where an invalid table item can be referred and that may lead to incorrect results / abnormal ends. SET statement Syntax: SET index-name-1 TO/UP BY/DOWN BY integer-1.
Binary SEARCH
When the size of the table is large and it is arranged in some sequence -either ascending or descending on search field, then BINARY SEARCH would be the efficient method. SEARCH ALL identifier-1 AT END imperative-statement-1 WHEN dataname-1 = identifier-2/literal-1/arithmetic expression-1 AND dataname-2 = identifier-3/literal-2/arithmetic expression-2 END-SEARCH. Identifier-2 and identifier-3 are subscripted items and dataname-1 and dataname-2 are working storage items that are not subscripted. Compare the item to be searched with the item at the center. If it matches fine, else repeat the process with the left or right half depending on where the item lies.
Sl # 1 2
Sequential SEARCH
Binary SEARCH
SEARCH Table should have INDEX. Table need not be in SORTED order. Multiple WHEN conditions can be coded. Any logical comparison is possible. Index should be set to 1 before using SEARCH Prefer when the table size is small
SEARCH ALL Table should have INDEX. Table should be in sorted order of the searching argument. There should be ASCENDING/DESCENDING Clause.
01 05 10 15 15 77
EMP-TABLE. DEPTNUMBER OCCURS 10 TIMES INDEXED BY I1. EMP-DETAIL OCCURS 50 TIMES INDEXED BY I2. EMP-NUMBER PIC9(04). EMP-SALARY PIC9(05). EMPNUMBER-IN PIC 9(04) VALUE 2052.
PERFORM 100-SEARCH-EMP-SAL VARYING I1 FROM 1 BY 1 UNTIL I1 > 10 OR WS-FOUND 100-SEARCH-EMP-SAL. SET I2 TO I. SEARCH EMP-DETAIL AT END DISPLAY NOT FOUND. == > Lowest Occurs WHEN EMPNUMBER-IN = EMP-NUMBER(I1,I2).
DISPLAY SALARY IS: EMP-SALARY(I1,I2). SET WS-FOUND TO TRUE. == > Search ends END-SEARCH.
Example:
IDENTIFICATION DIVISION. PROGRAM-ID. PGMA .. IDENTIFICATION DIVISION. PROGRAM-ID. PGMB .. END PROGRAM PGMB. . END PROGRAM PGMA.
If you want access any working storage variable of PGMA in PGMB, then declare them with the clause IS GLOBAL in PGMA. If you want to access any working storage variable of PGMB in PGMA, declare them with the clause IS EXTERNAL in PGMB. Nested Programs are supported only in COBOL85. If there is a program PGMC inside PGMB, it cannot be called from PGMA unless its program id is qualified with keyword COMMON.
MERGE
It is same as sort. USING is mandatory. There should be minimum two files in USING. MERGE Sort-work-file ON ASCENDING KEY dataname1 dataname2 USING file1 file2 GIVING file3 / OUTPUT PROCEDURE is section-1 END-MERGE Program sort registers (and its equivalent DFSORT parameter/meaning) SORT-FILE-SIZE (FILSZ), SORT-CORE-SIZE (RESINV), SORT-MSG(MSGDDN) SORT-MODE-SIZE (SMS=nnnnn) SORT-RETURN(return-code of sort) and SORT-CONTROL (Names the file of control card default is IGZSRTCD)
STRING MANIPULATION
A string refers to a sequence of characters. String manipulation operations include finding a particular character/sub-string in a string, replacing particular character/sub-string in a string, concatenating strings and segmenting strings. All these functions are handled by three verbs INSPECT, STRING and UNSTRING in COBOL. EXAMINE is the obsolete version of INSPECT supported in COBOL74.
STRING
STRING command is used to concatenate one or more strings. Syntax: STRING identifier-1 / literal-1, identifier-2/ literal-2 DELIMITED BY (identifier-3/literal-3/SIZE) INTO identifier-4 ENDSTRING. 01 VAR1 PIC X(10) VALUE MUTHU 01 VAR2 PIC X(10) VALUE SARA 01 VAR2 PIC X(20). To get display MUTHU,SARA STRING VAR1 DELIMITED BY , DELIMITED BY SIZE VAR2 DELIMITED BY INTO VAR3 END -STRING. The receiving field must be an elementary data item with no editing symbols and JUST RIGHT clause.
With STRING statement, specific characters of a string can be replaced whereas MOVE replaces the full string. 01 AGE-OUT PIC X(12) VALUE 12 YEARS OLD. STRING 18 DELIMITED BY SIZE INTO AGE-OUT. => 18 YEARS OLD.
UNSTRING
UNSTRING command is used to split one string to many strings. Syntax: UNSTRING identifier-1 [DELIMITED BY (ALL/) identifier2/literal1 [,OR (ALL/) (identifier-3/literal-2),..]] INTO identifier-4 [,DELIMITER IN identifier-5, COUNT IN identifier-6] [,identifier-7 [,DELIMITER IN identifier-8, COUNT IN identifier-9] 01 WS-DATA PIC X(12) VALUE 10/200/300/1. UNSTRING WS-DATA DELIMITED BY / INTO WS-FLD1 DELIMITER IN WS-D1 COUNT IN WS-C1 WS-FLD2 DELIMITER IN WS-D2 COUNT IN WS-C2 WS-FLD3 DELIMITER IN WS-D3 COUNT IN WS-C3 END-UNSTRING. Result: WS-FLD1 = 10 WS-FLD2 =200 WS-FLD3=300 WS-C1 = 2 WS-C2=3 WS-C3=3 WS-D1 = / WS-D2=/ WS-D3 =/ ON OVERFLOW can be coded with STRING and UNSTRING. If there is STRING truncation then the imperative statements followed ON OVERFLOW will be executed.
COPY Statement
A COPY statement is used to bring a series of prewritten COBOL entries that have been stored in library, into a program. 1.Common routines like error routine, date validation routine are coded in a library and bring into the program by COPY. 2. Master files are used in multiple programs. Their layout can be placed in one copybook and be placed wherever the files are used. It promotes program standardization since all the programs share the same layout and the same data names. This reduces coding and debugging time. Change in layout needs change in copybook only. It is enough if we just recompile the program for making the new copy effective. Syntax: COPY copybook-name [(OF/IN) library name] [REPLACING string-to-be-replaced BY replacing-string] Copybooks are stored as members in PDS library and during compilation time, they are included into the program. By default, the copybook library is SYSLIB and it can be changed using IN or OF of COPY statement. Copybooks can be used in the following paragraphs. SOURCE-COMPUTER, OBJECT-COMPUTER, SPECIAL-NAMES, FILE-CONTROL, IO-CONTROL, FD SECTION, PARAGRAPHS IN PROCEDURE DIVISION. If the same copybook is used more than once in the program, then there will be duplicate data declaration error during compilation, as all the fields are declared twice. In this case, one copybook can be used with REPLACING verb to replace high-level qualifier of the all the variables with another qualifier. Example: COPY CUSTOMER REPLACING CUST1- BY CUST2-. Delimiter = = should be used for replacing pseudo texts. The replacing option does not alter the prewritten entries in the library; the changes are made to the users source program only.
Sub-Program Changes:
WS-VAR1 and WS-VAR2 are working storage items of main program. As we have already mentioned, the linkage section is used for accessing external elements. As these working storage items are owned by main program, to access them in the sub-program, we need to define them in the linkage section. LINKAGE SECTION.
01 05 05
In addition to define them in linkage section, the procedure division should be coded with these data items for addressability. PROCEDURE DIVISION USING LK-VAR1,LK-VAR2 There is a one-one correspondence between passed elements and received elements (Call using, linkage and procedure division using) BY POSITION. This implies that the name of the identifiers in the called and calling program need not be the same (WS-VAR1 & LK-VAR1) but the number of elements and picture clause should be same. The last statement of your sub-program should be EXIT PROGRAM. This returns the control back to main program. GOBACK can also be coded instead of EXIT PROGRAM but not STOP RUN. EXIT PROGRAM should be the only statement in a paragraph in COBOL74 whereas it can be coded along with other statements in a paragraph in COBOL85. PROGRAM-ID. IS INITIAL PROGRAM. If IS INITIAL PROGRAM is coded along with program-id of sub program, then the program will be in initial stage every time it is called (COBOL85 feature). Alternatively CANCEL issued after CALL, will set the sub-program to initial state. If the sub program is modified then it needs to be recompiled. The need for main program recompilation is decided by the compiler option used for the main program. If the DYNAM compiler is used, then there is no need to recompile the main program. The modified subroutine will be in effect during the run. NODYNAM is default that expects the main program recompilation. Difference between Pass-by-reference and Pass-by-content
Sl #
Passl By Reference CALL sub1 USING BY REFERENCE WSVAR1 It is default in COBOL. BY REFERENCE is not needed. Address of WS-VAR1 is passed
Pass By Content CALL sub1 USING BY CONTENT WS-VAR1 (BY CONTENT keyword is needed) BY CONTENT key word is mandatory to pass an element by value. Value of WS-VAR1 is passed The sub-program modifications on the passed elements are local to that sub-program and not visible in the main program.
The sub-program modifications on the passed elements are visible in the main program.
Sl #
STATIC Call
DYNAMIC Call
Identified by Call variable and the variable should be populated at run time. 01 WS-PGM PIC X(08). Move PGM1 to WS-PGM CALL WS-PGM If you want convert the literal calls into DYNAMIC, the program should be compiled with DYNAM option. By default, call variables and any un-resolved calls are considered as dynamic.
Default Compiler option is NODYNAM and so all the literal calls are considered as static calls.
If the subprogram undergoes change, sub program and main program need to be recompiled. Sub modules are link edited with main module. Size of load module will be large Fast Less flexible. Sub-program will not be in initial stage the next time it is called unless you explicitly use INITIAL or you do a CANCEL after each call.
Sub modules are picked up during run time from the load library. Size of load module will be less. Slow compared to Static call. More flexible.
5 6 7
INTRINSIC FUNCTIONS:
LENGTH
:-
Returns the length of the PIC clause. Used for finding length of group item that spanned across multiple levels. Returns the content of the argument that contains the maximum value Returns the content of the argument that contains the minimum value Returns the numeric value represented by an alphanumeric character string specified in the argument. Same as NUMVAL but currency and decimal points are ignored during conversion. Returns 21 Chars alphanumeric value YYYYMMDDHHMMSSnnnnnn
MAX MIN
::-
NUMVAL
:-
:-
:-
:-
:-
:-
:-
FILE HANDLING
A data file is collection of relevant records and a record is collection of relevant fields. The file handling in COBOL program involves five steps.
Steps in file-handing
1.Allocation: The files used in the program should be declared in FILE-CONTROL paragraph of environment division. The mapping with JCL DDNAME is done here. The file is allocated to your program by this statement. 2.Definition. The layout of the file and its attributes are defined in the FILE SECTION of DATA DIVISION. 3.Open: Dataset is connected/readied to your program using OPEN statement. The mode of OPEN decides the operation allowed and the initial pointer in the dataset. For example, EXTEND mode allows only write access and the pointer is kept on the end of file to append. 4.Process: Process the file as per requirement, using the I-O statements provided by COBOL. (READ, WRITE, REWRITE and DELETE) 5. Close: After the processing, close the file to disconnect it from the program.
SELECT [OPTIONAL] FILENAME ASSIGN to DDNAME ORGANIZATION IS SEQUENTIAL/INDEXED/RELATIVE ACCESS IS SEQUNETIAL/RANDOM/DYNAMIC RECORD KEY IS FILE-KEY1 RELATIVE KEY IS WS-RRN ALTERNARE RECORD KEY IS FILE-KEY2 WITH DUPLICATES ALTERNARE RECORD KEY IS FILE-KEY3 WITHOUT DUPLICATES FILE STATUS IS WS-FILE-STAT1
::::::::-
ALL Files ALL Files ALL Files KSDS RRDS KSDS AIX ALL Files
[,WS-FILE-STAT2]
:-
VSAM Files
SELECT Statement-ORGANIZATION
It can be SEQUENTIAL (PS or VSAM ESDS), INDEXED (VSAM KSDS), RELATIVE (VSAM RRDS). Default is Sequential.
RANDOM.
Records can be randomly accessed in the program using the primary/alternate key of indexed file organization or relative record number of relative organization.100th record can directly be read after getting the address of the record from the INDEX part for INDEXED files.100th record can directly be read for RELATIVE files even without any index.
DYNAMIC.
It is mixed access mode where the file can be accessed in random as well as sequential mode in the program. Example: Reading the details of all the employees between 1000-2000. First randomly access 1000th employee record, then read sequentially till 2000th employee record. START and READ NEXT commands are used for this purpose in the procedure division.
RESERVE Clause.
RESERVE clause [RESERVE integer AREA ] can be coded in the SELECT statement. The number of buffers to be allocated for the file is coded here. By default two buffers will be allocated if the clause is not coded. Since similar option is available in JCL, this is not coded in program. RESERVE 1 AREA allocates one buffer, for the file in the SELECT statement. Defining the file in FILE SECTION FD FD FILENAME RECORDING MODE IS V/VB/F/FB
RECORD CONTAINS M CHARACTERS (TO N CHARACTERS) BLOCK CONTAINS X CHARACTERS/RECORDS (TO Y CHARACTERS/RECORDS) LABEL RECORDS ARE OMITTED/STANDARD DATA RECORD IS FILE-RECORD. 01 FILE-RECORD PIC X(nnn).
FD-RECORD CONTAINS
It specifies the length of the record in terms of bytes. (It will be RECORD contains m to n CHARACTERS for variable format files)
FD-BLOCK CONTAINS
It specifies the physical record size. It can be mentioned as number of logical records OR number of characters, that is multiple of logical record length. It is suggested to code BLOCK CONTAINS 0 RECORDS so that system will decide the optimum size for the file based on the device used for storing the file. BLOCK CONTAINS clause is treated as comments for VSAM files. Advantage of Blocking: 1. I-O time is reduced as n numbers of records are read into main memory buffer during an I-O. 2. Inter record gap is removed and the gap exist only between blocks. So memory wastage due to IRG is avoided.
FD-RECORDING MODE IS
It can be F (FIXED) V(VARIABLE) FB(FIXED BLOCK) VB(VARIABLE BLOCKED) Variable record file identification: If there is no recording mode/record contains clause, it is still possible to identify variable length records. If there is an OCCURS depending on clause or there are multiple 01 levels and every 01 level is of different size, then the file would be of variable length. Multiple 01 level in File section is an example for implicit redefinition.
OPEN STATEMENT
Syntax: OPEN OPENMODE FILENAME OPENMODE can be INPUT OUTPUT I-O EXTEND
::::-
File can be used ONLY-FOR-READ purpose. File can be used ONLY-FOR-WRITE purpose. File can be used FOR READ, WRITE and REWRITE purpose. File can be used FOR appending records using WRITE.
CLOSE statement.
The used files are closed using CLOSE statement. If you dont close the files, the completion of the program closes all the files used in the program. Syntax: CLOSE FILENAME
OPEN INPUT file-1 OPEN OUTPUT file-2 CLOSE file-3 CLOSE file-3
[WITH NO REWIND | REVERSED] [WITH NO REWIND] [{REEL|UNIT} [WITH NO REWIND| FOR REMOVAL] [WITH NO REWIND|LOCK]
READ statement
READ statement is used to read the record from the file. Syntax:
READ FILENAME
[INTO ws-record] [KEY IS FILE-KEY1] [AT END/INVALID KEY imperative statement1] [NOT AT END/NOT INVALID KEY imperative statement2]
END-READ
If INTO clause is coded, then the file is directly read into working storage section record. It is preferred as it avoids another move of file-section-record to working-storage-record followed by simple READ. READ-INTO is not preferred for variable size records where the length of the record being read is not known. KEY IS clause is used while accessing a record randomly using primary/alternate record key. AT END and NOT AT END are used during sequential READ of the file. INVALID KEY and NOT INVALID KEY are used during random read of the file. Before accessing the file randomly, the key field should have a value before READ.
WRITE Statement
Write statement is used to write a new record in the file. If the file is opened in EXTEND mode, the record will be appended. If the file is opened in OUTPUT mode, the record will be added at the current position. Syntax:
WRITE FILE-RECORD
END-WRITE
FROM clause avoids the explicit move of working storage record to file section record before WRITE.
REWRITE Statement
REWRITE is used to update an already read record. To update a record in a file, the file should be opened in I-O mode. Syntax:
REWRITE FILE-RECORD
END-REWRITE
START Statement
START is used with dynamic access mode of indexed files. It establishes the current location in the cluster for READ NEXT statement. START itself does not retrieve any record. Syntax:
START FILENAME
KEY is EQUAL TO/NOT LESS THAN/GREATER THAN key-name [INVALID KEY imperative statement1]
END-START.
DELETE Statement
DELETE is used to delete the most recently read record in the file. To delete a record, the file should be opened in I-O mode. Syntax:
DELETE FILENAME
END-DELETE.
RERUNONrescue FOR EVERY integer RECORDS on file-1 This will cause checkpoint to be taken for every interger-1 records processing of file-1. If the program ABENDED before the complete processing of the file-1, then the program will restart from integer+1ST record instead of first record. The rescue file details should be mentioned outside the program and it varies from installation to installation.
ENTRY statement
ENTRY statement establishes an alternate ENTRY point in a COBOL called sub-program. When a CALL statement naming the alternate entry point is executed in a calling program, control is transferred to the next executable statement following the entry statement. Except when a CALL statement refers to an entry name, the ENTRY statements are ignored at runtime.
Matching Logic
If you have been given two files of similar type, say master and transaction file and you are requested to update the master file with transaction file information for existing records and prepare a report of new transactions and deleted transactions, then you should go for what is called Matching logic. This is also known as co-sequential processing. Sort both the files on key and compare the keys. If the keys are matching then update the file. If you find any record that is found in transaction but not in master file, then that is new addition and the reverse is deletion. If the master key is greater than transaction key, then that corresponds to the first case and reverse is the second case. This can be easily done in JCL using ICETOOL.
N/A
5 7
N/A N/A A sequential READ statement was attempted and no next logical record existed in the file because the end of the file had been reached, or the first READ was attempted on an optional input file that was not present. A sequential READ statement was attempted for a relative file and the number of significant digits in the relative record number was larger than the size of the relative key data item described for the file. N/A
10
14
INVALID READ ATTEMPT ON RELATIVE FILE. THE GIVEN RRN NUMBER IS LARGER THAN THE RELATIVE KEY. A READ WAS ATTEMPTED WHEN AT THE END CONDITION IS TRUE. INVALID KEY.
16
20
N/A A sequence error exists for a sequentially accessed indexed file. The prime record key value has been changed by the program between the successful execution of a READ statement and the execution of the next REWRITE statement for that file, or the ascending requirements for successive record key values were violated.
21
22
DUPLICATE KEY
An attempt was made to write a record that would create a duplicate key in a relative file; or an attempt was made to write or rewrite a record that would create a duplicate prime record key or a duplicate alternate record key without the DUPLICATES phrase in an indexed file. This key value applies to an indexed file in which the alternate key has been declared UNIQUE. An attempt was made to randomly access a record that does not exist in the file, or a START or random READ statement was attempted on an optional input file that was not present. An attempt was made to write beyond the externally defined boundaries of a relative or indexed file. Or, a sequential WRITE statement was attempted for a relative file and the number of significant digits in the relative record number was larger than the size of the relative key data item described for the file. No further information A permanent error exists because of a boundary violation; an attempt was made to write beyond the externally-defined boundaries of a sequential file. An OPEN statement with the INPUT, I-O, or EXTEND phrase was attempted on a nonoptional file that was not present. An OPEN statement was attempted on a file that would not support the open mode specified in the OPEN statement. Possible violations are: 1. The EXTEND or OUTPUT phrase was specified but the file would not support write operations. 2. The I-O phrase was specified but the file would not support the input and output operations permitted. 3. The INPUT phrase was specified but the file would not support read operations. An OPEN statement was attempted on a file previously closed with lock.
23
24
NO MORE SPACE ALLOCATED TO FILE. WRITING BEYOND THE ALLOCATION OF THE FILE.
30
UNCORRECTABLE I/O ERROR. AN ATTEMPT WAS MADE TO WRITE BEYOND THE BOUNDARY OF THE FILE. ATEEMPTING TO OPEN AN EMPTY FILE IN INPUT OR I/O MODE. DD NAME IS MISSING OR WRONGLY GIVEN.
34
35
37
OPEN WAS ATTEMPTED ON A FILE THAT WILL NOT SUPPORT THE OPEN MODE SPECIFIED.
37
39
The OPEN statement was unsuccessful because a conflict was detected between the fixed file attributes and the attributes specified for that file in the program. These attributes include the organization of the file (sequential, relative, or indexed), the prime record key, the alternate record keys, the code set, the maximum record size, and the record type (fixed or variable).
40
RECORD IS INCONSISTENT WITH THE DESCRIPTION OF THE RECORD THAT HAS BEEN READ ATTEMPT TO OPEN A FILE WHICH IS ALREADY OPENED ATTEMPT TO CLOSE A FILE THAT IS NOT OPEN.
N/A
41
An OPEN statement was attempted for a file in the open mode. A CLOSE statement was attempted for a file not in the open mode. For a mass storage file in the sequential access mode, the last input-output statement executed for the associated file prior to the execution of a REWRITE statement was not a successfully executed READ statement. For relative and indexed files in the sequential access mode, the last input-output statement executed for the file prior to the execution of a DELETE or REWRITE statement was not a successfully executed READ statement. A boundary violation exists because an attempt was made to rewrite a record to a file and the record was not the same size as the record being replaced, or an attempt was made to write or rewrite a record that was larger than the largest or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated filename. A sequential READ statement was attempted on a file open in the input or I-O mode and no valid next record had been established because: 1. The preceding START statement was unsuccessful, or 2.The preceding READ statement was unsuccessful but did not cause an at end condition, or 3. The preceding READ statement caused
42
43
44
46
an at end condition. 47 ATTEMPT TO READ FROM A FILE WHICH IS NOT OPEN IN INPUT OR I-O MODE. ATTEMPT TO WRITE ON A FILE NOT OPEN IN OUTPUT OR EXTEND MODE. ATTEMPT TO WRITE ON A FILE NOT OPEN IN I-O MODE. VSAM START FAILURE. SOME TYPE OF VSAM LOGIC ERROR. PASSWORD FAILURE. DOING IN WRONG MODE. NOT ENOUGH VIRTUAL STORAGE FOR VSAM TASK. NO CURRENT POINTER FOR SEQUENTIAL PROCESSING. CONFLICTING ATTRIBUTES. NO CORRESPONDING DD STATEMENT FOR THE FILE. FILE NOT CLOSED BY PREVIOUS JOB. The execution of a READ statement was attempted on a file not open in the input or IO mode. The execution of a WRITE statement was attempted on a file not open in the I-O, output, or extend mode. The execution of a DELETE or REWRITE statement was attempted on a file not open in the I-O mode. N/A No further information. For VSAM only: Password failure. Logic error.
48
49
88 90 91 92
93
Resource not available. For VSAM with CMPR2 compiler-option only:No file position indicator for sequential request. For VSAM only: Invalid or incomplete file information. For VSAM only: No DD statement specified for this file. For VSAM only: OPEN statement execution successful: File integrity verified.
94
95
96
97
Advertisement
Cobol Coding
Good COBOL Coding practices for better Modularity and Performance. 1. 2. 3. Do not use 66 level. Planning of data definition should make this redundant Do not use 77 level. Collect all these together and group under a 01 level. Use 88 level appropriately. For conditional names. All level numbers increment by an odd number in order to allow for the insertion of extra levels during modifications; this reduces the need for wholesale renumbering of the levels with all the problems that this entails. 01 LEVEL1. LEVEL2. 10 LEVEL3
4.
05
5.
PARAGRAPHs or SECTIONs should be used; they should not be mixed except when the PARAGRAPH names are used to subdivide the SECTION. If this is used then only the SECTIONs should be performed. It corresponds to the sequence/logical position in the structure of the code. This enables the location to be easily ascertained in a listing and also allows the user to see where the program has progressed to in the event of any problems. The SORT and MERGE statements should be avoided if at all possible, it is more efficient to use an external sort, e.g. SYNCSORT/DFSORT, rather than calling the internal sort which also uses one of these sorts. This is because with an internal sort, control is passed back to the program after each record reducing the speed of the sort. It is also easier to debug a COBOL program than it is to debug the dump from an internal sort abend. If SORT routines are used then the maximum key length is 4092 bytes with no maximum number of keys. To increase the efficiency of the sort, keep
6.
7.
the key fields at the start of the record and as contiguous as possible. GOTO should never be used; a structured program should not need to use this command. If however because of coding or processing constraints, then the only possible use is to transfer control to the end of the SECTION or PARAGRAPH being processed. It MUST NOT be used in any other case. Nested IF statements should be avoided and consideration should be given to the use of EVALUATE as an alternative. The other option is to restructure the logic of the program so that the if statement is either eliminated or simplified. The WHEN OTHER must always be coded; if this is not present then if none of the prior conditions are satisfied then the program will fall through with no processing occurring. The WHEN OTHER statement should always be the last option; if it is not then all conditions following are irrelevant as they will not be tested. Care should be taken when using STRING and UNSTRING as this may hide data structures. When using these operations then the ON OVERFLOW clause should always be used; if this is not used then you are not notified of the incomplete operation and control passes to the next sequential statement. All structures are terminating with END-XXX. The READ and WRITE PARAGRAPH/SECTIONS should be grouped together For each file there should be a separate READ PARAGRAPH/SECTION with an AT END clause; this should be performed in all cases and the AT-END condition tested for sequential files or the return code. For each file there should be a separate READ section. This is to reduce the size of the load module as the machine instructions generated for the execution of a perform are less than that for a READ; it also means that the file is only read in the one place rather than it scattered throughout the program, easing maintenance. An initial value of spaces or zero can be given to an item either in the DATA DIVISION or the PROCEDURE DIVISION. In the latter division then there are two options for doing this, to move an initial value to the individual items or to use in COBOL II onwards, the INITIALIZE statement. The use of the VALUE field of the data division should be used to give an initial value to constants. For variables that are used in working storage the INITIALIZE statement should be used. The INITIALIZE statement is limited in that it will only move spaces (to alphanumeric) or zeros (to numeric) depending on the item definition. All numeric types are supported for this statement, zoned, packed, binary. If any other value is required as an initial value then this must be moved separately, it is still the case that this should be done in the initialization PARAGRAPH or SECTION that is performed prior to processing and at any other time as required. How the table has been defined in the DATA DIVISION controls the access method used to retrieve the data. If an index has been defined then the method used is SEARCH ALL if the data is in key sequence (and BATCH), else use SEARCH; if there are more than 10 entries, and the table will be heavily accessed consider sorting the data; if no index is present then use PERFORM VARYING to retrieve the data. An index is more efficient than a subscript; this is because a factor of the element size for the table is built into the index, ensuring that the displacement from the start of the table is known for the element and does not have to be calculated at run time as it does with subscripts. This increases the speed at which the elements can be accessed when an index is used. If a table is to be searched sequentially, then if possible put the
8.
9.
10.
11. 12.
13.
14.
15.
16.
17.
occurrences that are more likely to satisfy the requirements when a table is checked at the start. If the table is to be searched using a binary search, then the items must be stored in ASCENDING/DESCENDING key sequence. 18. Static call should be used when size is not an issue but speed is, or the program is called often. Or else use Dynamic call. The following keywords must not be used: NEXT SENTENCE ADD CORR, MOVE CORR MULTIPLY GO TO
19.
Advertisement
JCL is not necessarily difficult because most users only use a small set of similar JCL that never changes from job to job.
Interactive Processing means that you give the computer a command and the computer responds to your command
request. It is more like a conversation.
Batch Processing means that you give the computer a whole group of commands, usually in the form of some sort of
program you have written, and have the computer process this group of commands. It is more like writing a letter.
2. BASIC SYNTAX OF JCL STATEMENTS //NAME | name field OPERATION | operation field OPERAND,OPERAND,OPERAND | operand field COMMENTS | comment field
name field identifies the statement so that other statements or the system can refer to it. The name field must begin immediately after the second slash. It can range from 1 to 8 characters in length, and can contain any alphanumeric (A to Z) or national (@ $ #) characters. operation field specifies the type of statement: JOB, EXEC, DD, or an operand command. operand field contains parameters separated by commas. Parameters are composites of prescribed words (keywords) and variables for which information must be substituted. comments field optional. Comments can be extended through column 80, and can only be coded if there is an operand field. General JCL Rules: Must begin with // (except for the /* statement) in columns 1 and 2 Is case-sensitive (lower-case is just not permitted) NAME field is optional must begin in column 3 if used must code one or more blanks if omitted OPERATION field must begin on or before column 16 OPERATION field stands alone OPERANDS must end before column 72 OPERANDS are separated by commas All fields, except for the operands, must be separated by one blank.
JCL should be commented as you would any programming language. The comments statement contains //* in columns 1 to 3, with the remaining columns containing any desired comments. They can be placed before or after any JCL statements following the JOB statement to help document the JCL. Comments can also be coded on any JCL statement by leaving a blank field after the operand field.
4.1 ADDITIONAL OPERANDS OF THE JOB STATEMENT //jobname JOB USER=userid, TIME=m, MSGCLASS=class, NOTIFY=userid
USER=userid Identifies to the system the user executing the job TIME=m Total machine (m)inutes allowed for a job to execute MSGCLASS=class Output class for the job log NOTIFY=userid User to receive a TSO message upon completion of a job 4.1.1 MSGCLASS The MSGCLASS parameter allows you to specify the output class to which the operating system MVS is to write the job log or job entry subsystem (JES) messages. If you do not code the MSGCLASS parameter, MSGCLASS=J is the default and will be used. MSGCLASS=J indicates the output will be printed on 8 1/2 by 11 hole paper. This includes the following: 1. Job Entry Subsystem (JES) Messages 2. Error Messages 3. JCL Statements 4. Dataset Dispositions 5. Accounting information Here is a list of available output classes: A greenbar paper 5-9 TSO held output C-Z IBM page printer output classes. See chart in section Sys -out Classes for IBM Print on page 28.
//stepname EXEC procedure,REGION=####K or //stepname EXEC PGM=program,REGION=####K stepname an optional 1 to 8 character word used to identify the step EXEC indicates that you want to invoke a program or cataloged procedure procedure name of the cataloged procedure to be executed program name of the program to be executed REGION=####K amount of storage to allocate to the job
// Indicates JCL statements XX Indicates cataloged procedure statements X/ Indicates a modified cataloged procedures statement
ddname data definition name; a 1-8 character word of your choice, must begin with a letter or $, @, # DD DD statement identifier UNIT = unittype an I/O unit is a particular type of I/O device: a disk, tape, etc. UNIT=SYSDA refers to the next
available disk storage device.
DSN=userid.name DSN parameter names the data set. Data sets can be temporary or nontemporary. A temporary
data set is created and deleted within the job, whereas nontemporary data sets can be retained after the job completes. A data set name can contain up to 44 characters including periods. Ex. UGIBM.DATA
mgmtclas MGMTCLAS specifies the name of the Management Class which is a set of specifications for the way the
storage occupied by the data set should be treated by SMS. Generally, this deals with how long you want to keep this data set around. UCNS has set up the following management classes:
// // //
ddname data definition name; a 1-8 character word of your choice, must begin with a letter or $, @, # DD DD statement identifier UNIT=unittype an I/O unit is a particular type of I/O device: disk, tape, etc.
TAPE16 refers to a 1600 bpi tape drive TAPE62 refers to a 6250 bpi tape drive TAPECA refers to a 38K or XF catridge tape drive
VOL=SER=unitname VOL=SER parameter is needed if the data set is to be placed on a specific tape volume. This
refers to the volume serial number on an internal tape label.
DSN=filename DSN parameter names the file on the tape. The filename can be from 1 to 17 characters in length.
Ex. COWDATA 6.4.1 Disposition (DISP) Parameters The DISP parameter describes the current status of the data set (old, new, or to be modified) and directs the system on the disposition of the dataset (pass, keep, catalog, uncatalog, or delete) either at the end of the step or if the step abnormally terminates. DISP is always required unless the data set is created and deleted in the same step.
//
_________ _________________ ___________________ | | | NEW CATLG DELETE OLD KEEP KEEP SHR PASS CATLG MOD DELETE UNCATLG UNCATLG 6.4.1.1 Beginning Dispositions This is the status of the data set at the beginning of the step. If the data set is new, the system creates a data set label; if it is old, the system locates it and reads its label
NEW creates a new data set OLD designates an existing data set; it can be an input data set or an output data set to rewrite SHR identical to OLD except that several jobs may read from the data set at the same time. MOD modifies a sequential data set positions the pointer at the end of the data set in order to add new data to the data
set. 6.4.1.2 Normal Termination and Abnormal Termination Dispositions Normal disposition, the second term in the DISP parameter, indicates the disposition of the data set when the data set is closed or when the job terminates normally. The abnormal dispositions, effective only if the step abnormally terminates, are the same as normal dispositions except that PASS is not allowed.
PASS passes the data set on to subsequent job steps, and each step can use the data set once. KEEP keeps nontemporary data sets. DELETE deletes data sets.
CATLG catalogs a nontemporary data set. CATLG is similar to KEEP except that the unit and volume of the data set are
recorded in the catalog along with the data set name.
UNCATLG uncatalogs a data set. UNCATLG is the same as KEEP except that the data set name is removed from the
catalog. 6.4.1.3 Examples of DISP parameters
// DISP=SHR // DISP=OLD
read from write to create and catalog; delete if there is a system abend dataset already exists; pass it to the next step write to the bottom of an existing dataset
// DISP=(NEW,CATLG,DELETE)
// DISP=(OLD,PASS)
// DISP=MOD
6.4.2 SPACE Parameter All new data sets on disk volumes must be allocated space. Storage on disk volumes can be allocated in units of blocks, cylinders, tracks, kilobytes, and bytes. The space may be requested as a primary and a secondary amount. The primary amount is allocated when the data set is opened with a disposition of NEW. The secondary amount is allocated if the primary amount is exceeded. The primary amount can be conservative, with the secondary amount providing a reserve. The secondary amount provides for data set growth over time.
// SPACE=(TRK,(primary,secondary,directory)) primary
receive this amount of space initially
secondary receive this amount of space each time more is needed (up to 15 times) directory reserve this amount of blocks to keep the directory of a partitioned dataset (NOT USED for a sequential
dataset) 1 directory block allows for 5 members in a partitioned dataset Total Space = (1 * primary) + (15 * secondary) 6.4.2.1 Partitioned Dataset vs. Sequential Dataset Any named collection of data is called a data set. A partitioned dataset consists of multiple files within one data structure. A sequential dataset consists of one file within a data structure. Partitioned Dataset individual members are read/manipulated without disturbing other members it is advisable to never write directly to a partitioned dataset in your program on DD statememt: DSN=userid.file(member)
Sequential Dataset
dataset must be read from top to bottom on DD statement: DSN=userid.file call from editor: file
A partitioned dataset differs from a sequential dataset in that it has a directory of its members. Whenever you refer to a member of a partitioned dataset, you include the member name in parentheses. 6.4.2.2 DFSMS (System Managed Datasets) On the TSO service, data sets are typically created and reside on disk volumes. A volume is a standard unit of storage. These disk volumes are referred to as DASD, which stands for Direct Access Storage Device. Each block of data on a DASD volume has a distinct location and a unique address, making it possible to find any record without extensive searching. One DASD volume can be used for many different data sets, and space on it can be reallocated and reused. At theUniversityofGeorgia, you are now required to utilize the Data Facilities Storage Management Subsystem (DFSMS) to establish permanent data sets. The Storage Management Subsystem (SMS) is an operating environment that automates the management of storage. With SMS, users can allocate data sets more easily. The data sets allocated through the Storage Management Subsystem are called system-managed. System-managed means that the system determines data placement and automatically manages data availability, performance, space, reclamation, and security. One of the most beneficial goals of System-managed storage is to relieve users of performance, availability, space, and device management details. DFSMS stores data in a device-independent format so that it can easily move the data to any of the following devices: 3490E Magnetic Catridge Tape DASD for models 3380 and 3390
The migration and movement of data depends on such factors as: Management Class Data set Usage 76 Minimum percent free space on a DASD Volume Request by storage administrator or user
DFSMS records the location of each dataset it moves in a control data set. The actual migration is handled by DFHSM (Data Facilities Hierarchical Storage Manager). DFHSM is a DASD management product tool for managing low-activity and inactive data. Data sets that have reached the end of their retention period (expired) will be deleted. Data sets with a management class of STANDARD will be deleted if the data set has not been referenced for a period of eighteen months. A notification will be sent to the user after a STANDARD data set has not been referenced for six months informing the user of the STANDARD deletion policy. At this time the data set will be moved to tape. All data sets that have a management class of RETAIN95 or STANDARD will be automatically backed up by DFHSM. Two copies of each will be kept. The change indicator will trigger the backup after the first backup is made. A user can use the HBACK command to add non-STANDARD and non-RETAIN95 data sets to this. 6.4.2.3 SPACE Parameter (Partitioned Dataset)
// SPACE=(TRK,(primary,secondary,directory))
This SPACE example allows a total of 40 tracks for the dataset with 1 block of space reserved for the directory. // SPACE=(TRK,(10,2,1)) Total Space = (1*10) + (15*2) = 10 + 30 = 40 tracks Directory = (1*5) = 5 members/dataset This SPACE example allows a total of 100 tracks for the dataset with 8 blocks reserved for the directory. // SPACE=(TRK,(25,5,8)) Total Space = (1*25) + (15*5) = 25 + 75 = 100 tracks Directory = (8*5) = 40 members/dataset * Note that the track capacity for 3380 is 1 track = 47,476 characters. 6.4.2.4 SPACE Parameter (Sequential Dataset)
// SPACE=(TRK,(primary,secondary))
This SPACE example allows a total of 53 tracks for the dataset. // SPACE=(TRK,(8,3)) Total Space = (1*8) + (15*3) = 8 + 43 = 53 tracks This SPACE example allows a total of 520000 bytes for the dataset. // SPACE=(80,(5000,100)) Total Space = (1*400000) + (15*8000) = 400000 + 120000 = 520000 bytes * Note that directory blocks are always 0 for sequential datasets; therefore, the directory parameter is NOT USED for sequential datasets. 6.4.3 Data Set Attributes With SMS, you do not need to use the DCB parameter to specify data set attributes. ALL of the DCB keyword subparameters (record length, record format, and blocksize) can be specified without the need to code DCB=. For example, the following DD statement: // DCB=(RECFM=FB,LRECL=80,BLKSIZE=8000) can be specified as: // RECFM=FB,LRECL=80 The blocksize parameter can be omitted because SMS will select the optimum blocksize.
RECFM=xx specifies the record format. The format can be one or more of the following characters:
F fixed-length records V variable-length records U undefined-length records FB fixed and blocked FBA fixed, blocked, with ANSI carriage control characters VB variable and blocked VBA variable, blocked, with ANSI carriage control characters
6.4.3.1 Fixed Block // RECFM=FB,LRECL=80,BLKSIZE=9040 This dataset will have fixed length records with a length of 80. There will be 113 records of data per block. BLKSIZE/LRECL = 9040/80 = 113 records of data per block .4.3.2 Variable Block // RECFM=VB,LRECL=255,BLKSIZE=3120 This dataset will have variable length records with a maximum of 255 characters. The blocksize of the dataset will be 3120. 6.4.4 DCB and LABEL Parameters for Tapes RECFM=xx specifies the record format. The format can be one or more of the following characters: F fixed-length records V variable-length records U undefined-length records FB fixed and blocked FBA fixed, blocked, with ANSI carriage control characters VB variable and blocked VBA variable, blocked, with ANSI carriage control characters
must be equal to or greater than LRECL for variable-length records must be as large as the longest block for undefined-length records BLKSIZE can range from 1 to 32760 bytes
DEN=density measures the number of bits that are stored in a unit of measurement on the tape. This measurement is
commonly referred to as BPI (bits per inch). densities are represented in the DEN parameter as follows: 2 800 BPI 3 1600 BPI 4 6250 BPI * 38K OR XF BPI when adding files to an existing tape all new files will be written at the same density as the first file no matter if you specify differently. The LABEL parameter tells the type of label, the relative file number on the tape, and whether the data set is to be protected for input or output.
// LABEL=(file#,labeltype,,mode) file the relative file number on the tape (1-4 digits) type the type of label on the tape
NL No Label SL Standard Label AL American National Standard Label BLP Bypass Label Processing
//SASRUN JOB USER=UGIBM // EXEC SAS,REGION=2000K //OLDDATA DD DSN=UGIBM.DATA,UNIT=SYSDA,DISP=SHR //SYSIN DD * data one; infile olddata; input x y z; /* // 6.5.3 Fortran Job for Writing to Disk Dataset In this example, the userid UGABC is executing a Fortran procedure with the Fortran program inserted after the FORT.SYSIN line, and the results are written by UNIT 8 to the data set UGABC.NEWFILE. This dataset will only be retained for 7 days. If the user decides to keep the dataset for a longer period of time, the ALTER command can be issued. For example, ALTER UGABC.NEWFILE MGMTCLAS(RETAIN14), will keep the dataset around for another week. Since the BLKSIZE is not specified, SMS will determine the most efficient blocksize. //FORTRUN JOB USER=UGABC // EXEC FORTVCG,REGION=2000K //FORT.SYSIN DD * write(8,10) x,y 10 format(1x,f4.1,1x,f4.1) /* //GO.FT08F001 DD DSN=UGABC.NEWFILE,UNIT=SYSDA, // DISP=(NEW,CATLG,DELETE), // SPACE=(TRK,(40,10),RLSE), // RECFM=FB,LRECL=80,MGMTCLAS=RETAIN7 /* // 6.5.4 SAS Job for Writing to Disk Dataset In this example, the userid UGXYZ is executing a SAS procedure with the SAS program inserted after the SYSIN line and the results are written to the data set UGXYZ.SAS.DATA. This dataset, based on the management class of standard, will be retained on the system as long as the user utilizes it. //SASRUN JOB USER=UGXYZ // EXEC SAS,REGION=2000K //NEWDATA DD UNIT=SYSDA, // DSN=UGXYZ.SAS.DATA,DISP=(NEW,CATLG,DELETE), // SPACE=(TRK,(40,10),RLSE), // RECFM=FB,LRECL=80,MGMTCLAS=STANDARD //SYSIN DD * data example; input x y z; cards; 123 456 ; data _null_; set example; file newdata; put x y z; return; /* //
//ddname DD SYSOUT=class
ddname a 1 to 8 character name given to the DD statement DD DD statement identifier SYSOUT=class defines this data set as a system output data set, usually called a sysout data set and assigns this sysout data set to an output class. Here is a list of available output classes: A greenbar paper 5-9 TSO held output C-Z IBM page printer output classes. See chart in section Sysout Classes for IBM Print on page 28. * same class as specified on the MSGCLASS parameter * Note that if a sysout data set has the same class as the MSGCLASS parameter, the job log appears on the same output listing as this sysout data set.
7.1 SYSOUT CLASSES FOR IBM PRINT SYSOUT* CLASS C D F G H I J K Q S W X Y Z PAPER ORIENTATION SIDES IMAGES CHAR/LINE LINES/IMAGE
hole hole bond bond bond bond hole hole bond bond hole bond bond hole
landscape portrait landscape portrait landscape portrait landscape portrait landscape portrait portrait portrait landscape landscape
1 1 2 2 2 2 2 2 1 1 2 2 2 2
1 1 1 1 2 1 1 1 1 1 2 2 1 1
62 62 62 62 80 70 62 62 62 62 62 62 62 62
Graybar Overlay: The paper used for classes C,F,H,J, and Q is shaded to mimic standard greenbar paper. Service Site Page Printers: To route your output to one of the page printers in the Journalism or Aderhold sites, you must use a SYSOUT class or message class (MSGCLASS) with a paper type of hole (C, D, J, K, W, or Z). Line Printer SYSOUT Class: To route your output to a line printer, use a SYSOUT class or message class (MSGCLASS) of A. Your output will be printed on greenbar paper.
Special Hold Classes: To route your output to a hold queue, use a SYSOUT class or message class (MSGCLASS) of 5, 6, 7, 8, or 9. * SYSOUT class values may be used for message class (MSGCLASS).
//name OUTPUT FORMDEF=fdef,PAGEDEF=pdef,CHARS=ch,FORMS=form, // COPIES=n,DEST=dest,DEFAULT=dd name a 1 to 8 character name given to the OUTPUT statement OUTPUT OUTPUT statement identifier FORMDEF=fdef specifies whether to use duplex or simplex and overlay
DUP1 duplex, no overlay DUP2 duplex, grey bar overlay SMP1 simplex, no overlay SMP2 simplex, grey bar overlay
PAGEDEF=pdef specifies the logical page length and width, fonts, lines within a page, and multiple logical pages on a
physical page POR1 portrait, 62 lines at 6 lines per inch POR2 portrait, 70 lines at 6 lines per inch POR3 portrait, 2 up format, 62 lines per frame LAN1 landscape, 62 lines at 8 lines per inch LAN2 landscape, 2 up format, 80 lines per frame
COPIES=n specifies how many copies of the sysout data set are to be printed DEST=dest specifies a printer destination for the sysout data set
LOCAL Boyd Graduate Studies SSS02 Journalism Building SSS03 Aderhold Building NCT19 Brooks Hall
DEFAULT=dd specifies that this OUTPUT statement can or cannot be referenced by a sysout DD statement
YES specifies that this is the default OUTPUT statement for for all print files within a job NO specifies that this is not the default OUTPUT statement * Note if you are going to HOLD a print dataset with an OUTPUT statement associated with it, you will have to fully specify all of the parameters on the OUTPUT statement. Contact the UCNS Helpdesk for more details.
//OUT1 OUTPUT FORMDEF=DUP1,DEFAULT=YES To request simplex (one sided) printing for a duplex sysout class for all print files, code: //OUT1 OUTPUT FORMDEF=SMP1,DEFAULT=YES To request multiple copies of a print file, code: //OUT1 OUTPUT COPIES=12 - with //ddname DD SYSOUT=F,OUTPUT=*.OUT1
LINES specifies the maximum number of lines of data to be printed from this job in multiples of a thousand (default =
5000)
Priority
Setups Required 0 0
6 4
121-300
1-3
301+
4+
JCL Utilities:-
JCL statements :JOB statement :- The first statement in a job stream must be a job statement whose function is to identify the job to the
system.
EXEC statement :- The job statement is usually followed by an exec statement. The exec statement names the
program or the procedure that is to be executed.
DD statement :- Following the exec statement are the DD statements (data definition) statements. The DD statements
describe the data used by the program. The other JCL statements are delimiter, null, comment, proc & pend. An EXEC statement and its DD statements make up a job step. A job may consist of 255 job steps. The job, exec & DD statements have a common format which is :-
Naming conventions :Jobs will be held in datasets with .cntl or .jcl extension e.g. ORSDEVP.REL#15.JCL
Procedures will be held in datasets with .proclib or .proc extension e.g. ORSTEST.REL#15.PROCLIB Parameters used will be held in datasets with .parm or .parmlib extensions e.g ORSLIVE.REL#1.PARMS
Parameters :There are two kinds of parameters in the operand field :- positional andkeyword parameters. The
operating system recognizes positional parameters by their position in the operand field. Keyword parameters can be coded in any order. Positional parameters must be coded in a specific order before any keyword parameter.
Consider the job statement :Positional parameters 1. e.g.. accounting information & 1. programmers name. 2. 2. accounting information must precede the programmers name. 3. 3. if a positional parameter /sub parameter is omitted a comma must be coded in its place. Controlling step execution The COND parameter.
The COND parameter offers a method of testing the return codes issued by the previous steps to determine whether a step will be executed. The format of a simplified version of the COND parameter is COND =(value,operator). Value is a no. between0 and 4095 and operator could be gt, ge,eq, ne, lt, le. The COND parameter causes the value entered to be tested against the return codes from the previous steps, using the operator provided. If the test condition is true,the step is skipped.If the test condition is false,the step is executed.
Keyword parameters e.g.. class & msglevel. MSGLEVEL=(1,1) indicates print all the input JCL & the JCL from catalogued procedures & print all allocation messages. TYPRUN=SCAN causes the jobs JCL to be checked for syntax errors & prevents the job from executing.
Symbolic parameters
Symbolic parameters offer a convenient way of changing a procedure to fit your requirement. Consider the example procedure-proglod, sysctl, sym,etc. are all symbolic parameters. Symbolic parameter names may consist of from one to seven alphanumeric or national characters preceded by an ampersand. The first character however must be alphabetic / national. Exec statement keyword parameters may not be used as names of symbolic parameters.For e.g.. & REGION. This restriction does not extend to DD statement keyword parameters.For e.g. &DSN can be used as symbolic parameter.
Linkage parameter
Linkage parameters are used in COBOL programs. Linkage parameters are passed on to the COBOL programs through JCL by coding parm= parameter in the exec statement. Whenever linkage parameters have to be used, Linkage section has to be coded in the COBOL program after the data division and the procedure division should specify the use of linkage section. //DD400S01 EXEC PGM=DD400900,PARM=&PROCTYPE&DBNME&DICTNME
Generation Data Groups(GDG) A generation data group is a collection,or group,of cataloged data sets having the same name and related to one another chronologically. Each of these datasets is called a generation data set or,simply, a generation. Each generation data set is distinguished by others by the generation number.
The main advantage of using a GDG is that the same JCL can be reused without change. Generation group index contains information on how many generations are to be retained and what to do when the index gets full.
Defining a generation group index using IDCAMS :IDCAMS is the name of the access method services utility program that performs functions vital to the virtual storage access method(VSAM). IDCAMS requires a region of 300K, a SYSPRINT DD statement for messages and a SYSIN DD statement for control statements. The command format :-DEFINE GDG (PARMS).
Define GDG parameters Parameter NAME Abbrv Meaning GDD name. The no. Of generations permitted for this gdg The max is 255. If empty is specified, all data sets are to beremoved from the index when the limit is reached. NOEMPTY is the default. User identification (optional). If Scratch is specified, the dataset is scratched when the dataset is removed from the index NOSCRATCH is the default. Dataset retention period. Dataset retention period.
LIMIT
LIM
EMPTY
EMP
NOEMPTY OWNER
NEMP
SCRATCH
SCR
NSCR
DDSNUS.DEVTDV.DD460302,
then to access the current generation, you code DSN=DDSNUS.DEVTDV.DD460302(0). To access the previous generation, you code DSN= DDSNUS.DEVTDV.DD460302(-1) the generation before would be DSN= DDSNUS.DEVTDV.DD460302(-2). If you want to create a new generation, you code DSN= DDSNUS.DEVTDV.DD460302(+1). The absolute no. used by the system is in the form GXXXXVYY,where xxxx is ageneration no. from 0000 to 9999 and yy is a version no. from 00 to 99. Thus the generation specified as DSN= DDSNUS.DEVTDV.DD460302(0) might appear to the system, for e.g.. ,as DDSNUS.DEVTDV.DD460302.G0006V00. Then the data set with a relative no. of (-1) would beDDSNUS.DEVTDV.DD460302.G0005V00, (+1) would be DSNUS.DEVTDV.DD460302.G0007V00.
Libraries
Another name for a library is a partitioned data set(PDS). Libraries can be created,accessed & modified using utility programs like IEFBR14,IEBGENER, IEBPTPCH, IEBUPDTE, IEBCOPY, etc. IEFBR14, IEBGENER & IEBCOPY are the most frequently used utilities on any project.
IEFBR14
Strictly speaking it is not a utility program because it does nothing. It clears register 15 and BR(branch) 14. It is used to create or delete a library based on the DD statement parameters.
IEBGENER
IEBGENER uses four data sets described by SYSPRINT, SYSIN, SYSUT1 & SYSUT2. SYSPRINT is the DDNAME of the data set that IEBGENER uses to write messages. SYSIN is the DDNAME of the data set that contains the control statements to tell IEBGENER how the input data set
should be modified while it is being copied. SYSUT1 is the DDNAME of the input data set that IEBGENER is to copy. SYSUT2 is the DDNAME of the output data set that is to be created.
IEBCOPY
IEBCOPY is a utility program that may be used to copy one or more members from an existing PDS to a new or existing
PDS, to make a backup copy of a PDS, and to reorganize a PDS in order to reclaim the unused space.
DFSORT
Sorting means putting records in a data set into a specified order. Merging is closely related to sorting;it means combining records from two or more sorted datasets into one data set that is
in the same order. The sort program requires three pieces of information:where to find the input data,which fields in the records to do the sorting on, and where to put the sorted output data set.
A typical include statement would look like : INCLUDE COND=(29,1,CH,EQ,CL) The INREC & OUTREC statements : These statements are used to reformat the records. The INREC statement is used before sort to shorten the records by eliminating unwanted fields. This results in faster
sorting. The OUTREC statement is used after the sort to improve readability. INREC & OUTREC have identical formats: INREC FIELDS=(nX,position,length,align,)
OUTREC FIELDS=(nX,position,length,align,)
The first sub parameter,nX,is optional; it specifies the no. of spaces to be inserted in the reformatted record. The next two parameters, position & length, specify the field in the input record. The third sub parameter, align, is optional; the possible values being H, F, and D specify alignment on a half-word, fullword, and double-word boundary respectively.
Merging
When you merge, you start with two or more sorted data sets and create a new data set that is in the same sorted order. While merging you must specify more than one input data set. These data sets have the DD names SORTINnn, where nn may range from 01 to 16. SKIPREC & EQUALS / NOEQUALS options are not used on the merge statement. The sort control statements are normally coded in a parameter file.
DEFINE CLUSTER
is the command using which all the descriptive information about the VSAM data set is supplied.
REPRO
command may be used to load data into a VSAM data set.
PRINT
command is used to obtain a listing of a VSAM data set.
FILE-AID
utility from ISPF primary menu(v.1) can be used to allocate / manage VSAM data sets.
S001
S002
S004
Error occured during OPEN. Eg Invalid DCB. Error OPENing a dataset, eg PDS member does not exist, record length in program doesnt match datasets record length. Operation Exception. Check for subscript errors, missing DD card, file not opened. Protection Exception/Storage Violation. Trying to access storage not available to the program. Can be caused by a subscripting error or reading/writing a file that isnt open. Program Check Exception Data. Check for spaces in a packed decimal or numeric field. Check to see if record layouts or file layouts have been changed. Job has been cancelled. The value of x will vary depending on the way the job was cancelled. S222 means job was cancelled by a user or operator without a dump. If a TSO session times out you will probably get an S522 abend code. Unable Link or Load. The job was unable to find the specified load module. Check that the job is looking at the correct Load Libraries, specify a STEPLIB if required. Not enough Virtual Storage to satisfy a GETMAIN or FREEMAIN request. Unable to obtain to obtain enough space to satisfy a REGION= request May need to change REGION statement in the JCL.. Not enough storage available to satisfy a GETMAIN or FREEMAIN request.. Job was anable to allocate an area of memory of the correct size. Try Specifying or amending the REGION= JCL statement. You are trying to access a dataset which you are not authorized to use. Unable to allocate enough storage for a dataset. You might need to increase the amount of primary and secondary space to be allocated for a dataset in the SPACE= parameter, or you may have to move the dataset to a different DASD devive which has enought space to store the dataset. x will vary, likely Abends are SB37, SD37 or SE37. I/O Logic error. Typical reasons are; trying to write to a file
S013
S0C1
S0C4
S0C7
Sx22
S806
S80A
S822
S878
S913
Sx37
U1020
opened as input; Rewrite without a previous read. See the message IGZ020I for details of the exact reason. Inavlid OPEN/CLOSE. Check there is a DD statement for the file. See the message IGZ035I for more detailed information.
U1035
I/O ERROR I/O INVALID RECORD OPEN ERROR I/O SYNAD ERROR OPEN ERROR PAGING I/O ERROR PROGRAM CHECK EXCEPTIONS: 0C1 OPERATION PROTECTION / ADDRESSING ADDRESSING
0CX
0C4 0C5
NON-EXECUTABLE PROGRAM INSUFFICIENT VIRTUAL STORAGE UNABLE TO LOAD (LINK ETC) PROGRAM INSUFFICIENT VIRTUAL STORAGE INSUFFICIENT VIRTUAL STORAGE I/O ERROR
I/O ERROR INSUFFICIENT DASD SPACE INSUFFICIENT DASD SPACE INSUFFICIENT DASD SPACE
004(04)
Read past end of file You attempted to store a record with a Duplicate Key, or there is a duplicate record for an alternate index with the unique key option. You attempted to store a record out of Ascending Key Sequence in Skip-Sequential Mode; record had a Duplicate Key; for Skip-Sequential processing your GET, PUT, and POINT Requests are not referencing records in Ascending Sequence; or, for Skip-Sequential Retrieval, the key requested is lower than the previous key requested. For Shared Resources, buffer pool is full. Record not found. Record already held in exclusive control by another requester. Record resides on a volume that cannot be mounted. Data set cannot be extended because VSAM cant allocate additional Direct-Access Storage Space. Either there is not enough space left to make the secondary allocation or you attempted to increase the size of a data set while processing SHROPT=4 and DISP=SHR. KeyRangeswere specified for the data set when it was defined but no range was specified that includes the record to be inserted. Insufficient Virtual Storage to complete the request. 044(2A) Work area too small. 064(40) All available strings are in use. You attempted to use a type of processing (Output or Control-Interval Processing) that was not specified when the data set was opened.
008(08)
012(0C)
016(10)
020(14)
024(18)
028(1C)
036(24)
040(28)
068(44)
074(4A)
Trying to use keys on ESDS or RRDS. You issued an Addressed or Control-Interval PUT to add to a Key-Sequenced data set, or issued a Control-Interval put to a Relative Record data set. Trying to delete from ESDS. Using OPTCODE=LOC for a PUT. You issued a Sequential GET request without having caused VSAM to be positioned for it, or you changed from Addressed Access to Keyed Access without causing VSAM to be positioned for Keyed- Sequential Retrieval; there was no Sequential PUT insert for a Relative Record data set, or you attempted an illegal switch between forward and backward processing. A PUT for update or an ERASE was issued without a previous GET for update, or a PUTIX was issued without a previous GETIX. Changing the Prime Key or Key of Reference when making an update. 100(64 Trying to change record length. he RPL options are either invalid or conflicting. 108(6C) RECLEN specified was larger than the maximum allowed, equal to 0, or smaller than the sum of the length and the displacement of the key field; RECLEN was not equal to record (SLOT) size specified for a Relative Record data set. Invalid key length. Trying to update an empty dataset. Request was submitted by the wrong task. 132(84) An attempt was made in Locate Mode to retrieve a Spanned Record. You attempted an Addressed GET of a Spanned record in a Key- Sequenced data set. Inconsistent Spanned record. Invalid pointer (no associated base record) in an Alternate Index.
076(4C)
080(50) 084(54)
088(58)
92(5C)
96(60)
104(68)
112(70) 116(74)
120(78)
136(88)
140(8C)
144(90)
Maximum number of Alternate Index pointers exceeded. Not enough buffers available. Invalid control interval. Invalid Relative Record number in a RRDS dataset. Addressed access to a Relative Record (RRDS) dataset is not allowed. Addressed Access or Generic Backward processing by Key thru a path is not allowed. Attempting a PUT in backward mode. Record mode processing is not allowed for a Linear data set.
196(C4)
200(C8)
204(CC) 252(FC)
144(90)
148(94)
152(98)
164(A4)
168(A8)
176(B0)
180(B4)
A VSAM catalog specified in JCL either does not exist or is not open, and no record for the data set to be opened was found in any other catalog. An uncorrectable I/O error occurred while VSAM was completing an I/O request. The data set indicated by the Access-Method Control Block is not of the type that may be specified by an AccessMethod Control Block. An unusable data set was opened for output. Reset was specified for a nonreusable data set and the data set is not empty. A permanent Staging error occurred in MSS (Acquire). The Volume containing the Catalog Recovery area was not mounted and verified for output processing.
184(B8)
188(BC)
192(C0)
232(E8)
236(EC)
244(F4)
JCL FAQs :Question: What is the parameter to be passed in the job card for the unlimited time, irrespective of the job class? Answer: TIME=1440 Question: How do you submit JCL via a Cobol program? Answer: Use a file //dd1 DD sysout=(*,intrdr)write your JCL to this file. Question: Definition of COND p-r in JCL and a correction to a previously posted question
Answer: COND is a condition parameter, consists of 2 subparameters, 1st return code from the previous step, 2nd condition. If COND is true, the step on which COND is coded will be BYPASSED. Question: Q) WHAT IS MEANT BY S0C7 AND S0C30 SYSTEM ABEND CODES. Answer: A) S0C7 Data exception error you will get it whenever you are trying to move the low values or spaces into the numeric field, or compare the numeric fields with low values, or try to do some arithmetic operations on the low values. To avoid this you have to always initialize the numeric fields otherwise they will contain the low values. B)S0C 30 I have never heard of it, let you know if I come accross it. Question: How to pass the temp dataset form one JOB step to another? Answer: By specifying the DISP as PASS for the temp dataset Question: What is a COND parameter in JCL? Answer: COND means condition parameter. It is compared with system return code of previous step. //step1 exec pgm=abcd//step2 exec pgm=xyz, cond=(4,lt) step2 will be executed when system return code of step1 is less than 4. Question: WRITE A JCL TO EXECUTE A JOB BY7 A.MONJAN 20,1986? Answer: THE code IS: //*MAIN DEADLINE=(0700,B, 012086) Question: HOW MANY TYPES OF LIBRARIES ARE THERE IN JCL? Answer: LIBRARIES ARE OF THREE TYPES. 1.SYTEM LIBRARIES: SUCH AS SYS1.LINKLIB 2.PRIVATE LIBRARIES: SPECIFIED IN A JOBLIB OR STEPLIB DD STATEMENTS. 3.TEMPORARY LIBRARIES: CREATED IN A PREVIOUS STEP OF THE JOB. Question: WHAT U MEANS BY INCLUDE STATEMENT IN JCL? Answer: AN INCLUDE STATEMENT IDENTIFIES A MEMBER PF A PDS OR PDSE THAT CONTAINS.THIS SET OF JCL STATEMENTS IS CALLED AN INCLUDE GROUP.THE SYSTEM REPLACES THE INCLUDE STATEMENT WITH THE STATEMENTS IN THE INCLUDE GROUP. Question: THE MAXIMUM NUMBER OF IN-STREAM PROCEDURE YOU CAN CODE IN ANY JCL IS? Answer: 15. Question: What you mean by skeleton Jell? Answer: Jell which changes during run time i.e. the values for the jell such as pigmy name ,did name will change .i.e. same jell can be used for various job, equivalent to dynamic sql Question: How do you submit a JCL under CICS environment? Answer: Edit the JCL in Extra partition TDQ and submit the same using some system command (not sure) under CICS subsystem. This is what i think, please clarify. Question: what is JCL Answer: It is interface between operating system (mvs) & application program. when 2 related programs are combined together on control statements is called job control language
Question: What is the max blocksize for a Tape file? Answer: It is 32,760.Based on that we can calculate efficient number of Records in a Block Question: What are the basic JCL Statements for a Job? Answer: 1.JOB : Identifies a job and supplies accounting info. 2.EXEC: Identifies a job step by indicating the name of the program to be executed. 3.DD: Identifies a data set to be allocated for the job step. 4.Delimiter (/*): Marks the end of an in-stream dataset. 5.Null (//):Marks the end of a job. 6.Comments (//*): Provides Comments. 7.PROC : Marks the beginning of a procedure. 8.PEND : Marks the end of a procedure. 9.OUTPUT: Supplies options for SYSOUT processing. Question: What does the statements: type run=scan and type run=hold doing a JCL statement Answer: Typrun=scan checks the JCL for errors, Typrun=hold holds the job until further notice. Question: Which of the following is online transaction? CICS, DB2 and JCl Answer: CICS Question: How many PERFORMs are there in COBOL -II? Answer: 5 Question: which is the most widely used batch performance monitor for DB2? Answer: DB2PM Question: What is QSAM error usually when it is occurs? Answer: Usually it is occurs at the time of job submission. Question: what is the purpose of include statement in a jcl? Answer: It is used as an alternative for steplib.When we specify the dataset name in include, it will search in all the datasets specified in the include dataset. Question: IS IT POSSIBLE TO KNOW THE REMAINING FREE SPACE IN AN CONTROL INTERVAL/CONTROL AREA ONCE AN INSERTION HAS BEEN MADE. Answer: NOT POSSIBLE Question: what does soc04 error mean? Answer: This error is faced when we execute the cobol program.the main reason for this error is that a variable is defined with less characters and we are trying to move data which is larger than the actual storage space.
Question: What is JCL Answer: JCL is Job Control Language and is used for Batch processing. The startup procedures of OS and standard products like CICS etc are written in JCL. Question: In which table PLAN is registered in? Answer: RCT Question: GDG? Answer: GDG group of dataset that are logically or chronologically related, referred by name and a relative generation number an integer which identifies the generation of a dataset and is coded in parentheses after dataset name. Absolute GDG name GxxxxVyy, where xxxx-absolute gen.number, yy-version number. Can be sequential, direct, partitioned. (VSAM no). Must always be cataloged. Advantage all datasets have the same name and system keeps track of adding new and retaining previous generations and deleting oldest successive generation. To create a GDG we create a GDG index in the system catalog with IDCAMS utility and then a model (prototype, DSCB) on the same volume to supply DCB information. Empty when limit is reached all members are removed from the index, otherwise-only oldest. Scratchremoved members are uncataloged & deleted, otherwise removed & uncataloged, but remain in the system (not members of GDG any more). GDG number is updated at the end of the job. If number is not specified all generations will be processed from the beginning. Question: what is jcl Answer: It is used to communicate between the terminals. Question: what do you mean By spooling? Expand SPOOL? Answer: This is managed by JES.This is used for Queuing the Outputs that are intended for Printing and are first stored in SPOOLDASD. This can be managed Using Question: How many Instream-Procedures(procs) can be Coded in a single Job? Answer: The Answer is: 15 Question: FOR HOW LONG A JOB CAN BE EXECUTED CONTINUEOUSLY IN A MAINFRAME Answer: 248 DAYS Question: How may divisions are there in JCL-COBOL? Answer: SIX Question: MAX. NO OF DD STATEMENTS IN A JOB Answer: 3273 Question: HOW MUCH SPACE OS ALLOCATES WHEN YOU CREATE A PS OR PDS? Answer: 56 KB Question: MIN NO OF DATASET NAMES(PDS) IN ONE DIRECTORY BLOCK? Answer: SIX Question: THE MAXIMUM NUMBER OF STEPS IN A JOB? Answer: 255 Question: How much is memory space involved, when we code BLOCKSIZE, TRK & CYL
Answer: One block constitutes 32KB of formatted memory/ 42KB of Unformatted memory,6 blocks makes one Track & 15 Tracks makes one cylinder. Question: What is DSNDB06? Answer: This is the Place where DB2 Catalog resides. Question: What is the use of DSNDB07 ? Answer: This is the area where sorting takes place in DB2. Question: What is the purpose of Identification Division? Answer: Documentation. Question: WHAT IS DATACOM DB? Answer: IT IS A DATABASE USED WITH VSE. Question: What is a Dummy Utility and what it does ? Answer: IEFBR14 is a Dummy utility and it is used for the sake of EXEC PGM= . Statement in JCL[when used it wouldn't perform any task]. e.g. While Allocating a dataset you dont have to run any utility [this could be done by giving disp=new inDD statement]. But for a PGM name must be given in EXEC statement, it is used. Question: What 3 guidelines do we have to follow when concatenating DD statements? Answer: 1. Datasets must be of the same type (disk or tape) 2. All datasets must have the same logical record length 3. The dataset with the largest block size must be listed first. Question: On the DD statement, what is the main difference between creating a new sequential flat file and a partitioned dataset? Answer: SPACE=(n,m) for a sequential file, SPACE=(n,m,p) for a PDS where n, m, and p are numbers. The p designates how many directory blocks to allocate. Question: What is the difference between IEBGENER, IEBCOPY and REPRO in IDCAMS utility? Answer: IEBGENER This is a dataset utility for copying sequential datasets which produces a PDS or a member from a sequential dataset. IEBCOPY This is a dataset utility for copying one PDS to another or to merge PDSs.REPRO This is for copying sequential datasets. Question: How do you submit JCL via a Cobol program? Answer: Use a file //dd1 DD sysout=(*,intrdr)write your JCL to this file. Pl some on try this out. Question: How to execute a set of JCL statements from a COBOL program Answer: Using EXEC CICS SPOOL WRITE(var-name) END-EXEC command.var-name is a COBOL host structure containing JCL statements. Question: What is the difference between static call & Dynamic call Answer: In the case of Static call, the called program is a stand along program, it is an executable program . During run time we can call it in our called program. As about Dynamic call , the called program is not an executable program it can executed thru the called program
Question: What is the difference between catalouge procedure and In-Stream procedure? Answer: In Stream procedures are set of JCL statements written between JOB and EXEC statements, start with PROC and end with PEND statement.Mainly used to test catalog procedures. Cataloged procedure is cataloged on the procedure library and is called by specifying the procedure name on the EXEC statement. Question: What do you feel makes a good program? Answer: A program that follows a top down approach. It is also one that other programmers or users can follow logically and is easy to read and understand. Question: Can we browse or edit the GDG dataset if it is a tape entry? Answer: No Question: What are the maximum and minimum sizes of any CONTROL AREA (VSAM datasets) ? Answer: Minimum Size : 1 track Maximum size : 1 cylinder Question: HOW TO GET CURSOR POSITION FROM SYSTEM IN CICS ENVIRONMENT ? Answer: GET IT FROM EIBCURPOS ! Question: How many parameters are there to a DISP statement and what are their uses. Answer: There are three(3) parameters. Parameter 1: current data set disposition(new, shr, old, mod) Parameter 2: normal close action for data set (catlg, keep, delete) Parameter 3:abend action for data set (catlg, keep, delete). Question: What is the error code SOC01 indicate ? Answer: Operation exception error For eg a dataset open error Question: WHAT IS COMM? Answer: COMM HALF WORD BINARY Question: What is a procedure? Answer: A set of precoded JCL that can be modified through the use of parameters or override cards. Note: Procedures can be catalogued or instream. Question: What is the difference between specifying DISP=OLD and DISP=SHR for a dataset? Answer: OLD specifies exclusive use of a dataset, SHR allows multiple jobs to concurrently access the dataset Note: When updating a dataset, you would normally use OLD. Question: What are the three basic types of statements in a job stream? Answer: JOB(one per job stream)EXEC(one or more per job)DD(one or more per jobstep) Question: What does SYSIN * indicate? Answer: Instream data follows this card and is terminated when followed by a card containing // or /* in columns 1 and 2. Question: What are three major types of JCL statements? What are their functions?
Answer: JOB, EXEC, DD. JOB indicates start of jobstream to the operating system and through parms coded on it, certain details about the job (time, region, message level, job accounting data). EXEC indicates the start of execution of a particular job step, be that step a program or a proc.DD is a data definition, which is used to describe the attributes of a data set (name, unit, type, space, disposition). Question: What happens if the Time specified is exceeded ? Answer: The job ends with the ABEND code S322. Question: Abbreviation of ST. Answer: ST stands for STATUS. Question: What
is STEPLIB, JOBLIB? What is it used for? What is order of searching of the libraries in a JCL?
Answer: Specifies that the private library (or libraries) specified should be searched before the default system libraries in order to locate a program to be executed. STEPLIB applies only to the particular step, JOBLIB to all steps in the job.First any private libraries as specified in the STEPLIB or JOBLIB, then the system libraries such as SYS1.LINKLIB. The system libraries are specified in the linklist. Question: What is primary allocation for a data set? Answer:The space allocated when the data set is first created. Question: What is the difference between primary and secondary allocations for a data set? Answer: Secondary allocation is done when more space is required than what has already been allocated. Question: How many extents are possible for a sequential file ? For a VSAM file ? Answer:16 extents on a volume for a sequential file and 123 for a VSAM file. Question: What does a disposition of (NEW,CATLG,DELETE) mean? Answer:That this is a new dataset and needs to be allocated, to CATLG the Data set if the step is successful and to delete the data set if the step abends
CICS Tutorial :-
CICS
INTRODUCTION
BATCH & ONLINE SYSTEM
ONLINE SYSTEM DEFINITION : ONLINE processing allows a user to interact with a computer and access its resources via a terminal. Example : Railway Reservation system.
BATCH & ONLINE SYSTEM BATCH Data from card tape, disk Batched, sequential, scheduled ONLINE
Input
Start of A job
Operator (or operating system) initiates the job. Other jobs in the same region must wait.
Once CICS is initialized, entering transaction id triggers the transaction to start. Multi task multi thread. Priority processing. Each transaction. Once CICS is terminated, no transactions can be entered. Message terminals updated files, system Instant feed back More
Processing Mode
End of job
Each job
Output
printed reports, output files. User must wait for batch jobs to produce reports (day, week, month) Less
Customer Information Control System (CICS) was developed in 1960 by IBM ONLINE CONTROL SYSTEM
General purpose data communication control system Provides services to handle all the special requirements for online processing
Note : Role of CICS is to interface between application programs and the DB/DC control system.
CICS START UP
CICS is submitted as a batch job. CICS System Initialization program (SIP) is the main job step SIP loads System Initialization Table (SIT) SIP further loads all control programs and tables - Perform initial housekeeping tasks
CICS SHUTDOWN
Master terminal transaction is entered with shutdown option CICS job produces various logs, statistics, dumps and other reports and ends
ROLE OF CICS
o o o o MULTI TASKING More than one task can be executed concurrently. MULTI THREADING Tasks share the same program under the multi tasking environment. RE-ENTRANT PROGRAM Program when does not modify itself in any way during execution. QUASI RE-ENTRANT Is a reentrant program under the CICS environment.
SYMBOLIC MAP
1. Ensures the device and format independence to the application programs 2. A layout change in the formatted screen can be done independent of the application program coding as long as field name and length remain the same 3. Symbolic map is included in the program by issuing a COBOL COPY statement
Halfward binary Contain the length of data entered by the terminal operator One byte flag field Contains the data entered by the operator One byte field that contains Attribute byte Contains data to be sent to terminal
F I A O
SYMBOLIC MAP FORMAT A 12 byte TIOA prefix is automatically provided. When performing input functions fields suffixed with L, F, and I are meaningful. When performing OUTPUT functions, the fields suffixed with A and O are meaningful.Contains the data to be sent to the terminal.
DATA ONLY
EXEC CICS SEND MAP (mapname1) MAPSET (mapset1) DATA ONLY. END-EXEC. 1. MAP ONLY option. Use the physical map only. Field headings, attribute bytes, and the location of where all information is to be placed is sent.
1. DATA ONLY Use the symbolic map only only the data in the symbolic map is sent to the screen.
1. Neither MAPONLY NOR DATAONLY EXEC CICS SEND MAP (map-name1) MAPSET (mapset1) END-EXEC The physical map and the data from symbolic map is sent to the terminal.
Other options of SEND command. ERASE: Current screen is erased before the map specified appears on the screen ERASEAUP: erase all the unprotected fields. FREEKB: to free the keyboard ALARM: to make an alarms sound. FRSET: to reset MDT to zero CURSOR: to place the cursor in a specified field
CURSOR POSITIONING
o o o o o Static positioning If IC option is specified in the ATTRB field of DFHMDF macro the cursor will be placed at this field. Dynamic / symbolic positioning. Place (-1) into the field length field (L suffix). Cursor will be placed in the field. Dynamic / Relative positioning. Cursor (data-value) option is used. Data-Value will have the value at which the cursor has to be positioned. E.g.. EXEC CICS SEND MAP (..) MAPSET (..) CURSOR (100) ERASE END-EXEC. o o MAPFAIL condition will caused in RECEIVE MAP command. If the data to be mapped has a length of zero. If the operator presses any key (clear, PA, PF, ENTER, Keys) without entering any data.
LINKAGE SECTION Copying a symbolic description map structure here does NOT mean the storage will be available. Some methods for providing storage are passing a COMMAREA, acquiring temporary storage with the SET option, or using a GET MAIN command.
SEND / RECEIVE
SEND MAP (`MAP1) MAPSET(`SET1) MOVE `MAP1 TO MAPVAR MOVE `SET1 TO SETVAR SEND MAP (MAPVAR) MAPSET(SETVAR) FROM (MAP1O)
o
SEND MAP Coding Alternatives You can code the SEND MAP command to locate the
symbolic description map in several ways: Using constants in the name field for MAP and MAPSET(FROM is not required) Using variables in the name field for MAP and MAPSET (This makes FROM a required parameter) Using only the MAP parameter. In this case the name in the MAP option must be the MAPSET name.
RECEIVE MAP(`MAP1) MAPSET(`SET1) MAP1 I Move `MAP1 to MAPVAR Move `SET1 to SETVAR .. MAP1 I RECEIVE MAP (MAPVAR) MAPSET(SETVAR) INTO (MAP1 I) Receive MAP (`SET1) SET1 I
o
RECEIVE MAP coding alternatives You can code the RECEIVE MAP command to locate
the symbolic description map in several ways: Using constants in the name field for map and mapset (INTO/SET is not required) This is the most commonly used format. Using variables in the name field for MAP and MAPSET. This makes INTO (database) or SET a required parameter. Using only the MAP parameter. In this case the name in the MAP option must be the MAPSET name.
Linkage Section. 01 DFHCOMMAREA 01 LST 02 PTR-2-LIST PIC S 9(8) COMP. 02 PTR-2-BMS PIC S 9(8) COMP. RECEIVE MAP (`MAP1) MAPSET (`SET1) SET (PTR-2-BMS) .. MAP1 I
Using the SET option requests CICS to get the storage and return a pointer to it. The symbolic description map must be in the LINKAGE SECTION.
OUTBOUND FUNCTIONS SEND MAP (`MAPA) MAPSET (`SETA) [ERASE/ ERASEAUP] [FREEKB] [ALARM] [FRSET] [PRINT]
Erase Buffer, place cursor in upper left corner then write Erase all the unprotected fields before the Write Unlock Keyboard after the write Active alarm with the write Set all MDT currently on to off Start the 3270 print operation.
Control Functions:
Typically the first type of command in the program is a SEND MAP. Certain control functions may be included in that command. ERASEAUP will clear out each field whose attribute is unprotected. It will NOT alter any attribute settings. If you do not free the keyboard using FREEKB, the operator will have to press the RESET key before entering data. If you code FRSET, all attribute bytes currently having Modified Data Tags (MDT) set on will be set off. Selective resetting of the MDTs must be done another way. When sending data to a 3270 screen the actual printing from the buffer will occur when the PRINT function is requested.
Attributes :
The `A suffixed field is an attribute field which controls the following:
If the color or highlighting of a field has to be changed, additional symbolic fields are needed which are called the EXTENDED ATTRIBUTES.
EXTENDED ATTRIBUTES
DSATTS (for symbolic map) and MAPATTS (for physical map) support the extended attribute characteristics The MAPATTS allows you to set up the physical map with any of the characteristic(s) coded. The DSATTS will create appropriate suffixed labels for the attribute characteristic(s) coded.
EIBAID/CURSOR
WORKING-STORAGE SECTION. COPY DFHAID. PROCEDURE DIVISION. IF EIBAID = DFHPF12 THEN IF EIBAID = DFHENTER THEN IF EIBCPOSN LESS THAN 80 THEN When you first enter your program as a result of a transaction id, you can test EIBAID and/or EIBCPOSN. This may be done prior to issuing a RECEIVE command, if so chosen.
CURSLOC
Sample Map
MAPSETA DFHMSD TYPE=&SYSPARM, MODE= INOUT, TERM=ALL, LANG=COBOL, TIOAPFX=YES, STORAGE=AUTO MAP1 DFHMDI SIZE=(24,80), LINE=1, COLUMN=1, CURSLOC=YES DFHMDF POS(2,1), LENGTH=4, INITIAL=`NAME, ATTRIB=ASKIP NAME DFHMDF POS(2,6),LENGTH=20,
ATTRB=(UNPROT, IC) DFHMDF POS(2,27), LENGTH=1, ATTRB=PROT CURSLOC= YES allows you to determine after a RECEIVE MAP command, which map field had the cursor in it. CURSLOC=NO is the default. CURSLOC=(NO/YES) may be coded on the DFHMSD or the DFHMDI macro. If coded on the DFHMSD macro, it will provide a default for all the maps in that mapset. When CURSLOC=YES, BMS will set the `F suffix field to X02 indicating that field contained the cursor. If the cursor is in a field for which there is no symbolic label i.e. a DFHMDF with no label the program will not be notified. Note : The `F suffix field continues. To be used to indicate the operator pressed the erase to end of fixed (EOF) key by being set to X80. Therefore, if CURSLOC=YES it is possible to have both these conditions occur for the same field, in which case the `F suffix field will contain a X82.
EDITING
Map field Definition PICIN/PICOUT Built in function De-edit command. When data is sent out via the `O suffix fields or received into the `I suffix fields you may want a definition other than PIC x. PICIN AND PICOUT allows the user to use other COBOL PICS such as $,Z etc. If the date contains special characters, you may want to remove them using the BIF DEEDIT command.
FIELD EDIT BUILT-IN FUNCTION Amount $5431.80 BIF EDIT Amount 00543180
The Amount field displayed has a dollar sign and a decimal point By using BIF DEEDIT dollar sign and decimal point is removed. Thus the number can be used for arithmetic operations. COBOL compiler requires LENGTH specification: VS COBOL-II uses the implied length of the data-area used in the field parameter.
Environment Division
Other requirements: COBOL statements and CICS commands should be coded The following COBOL statements are prohibited. ACCEPT, CURRENT-DATE, DATE, DAY, DISPLAY, EXHIBIT, STOP RUN, TRACE Any I/O Statements(OPEN, CLOSE, READ, WRITE, REWRITE, DELETE, START) REPORT WRITER feature SORT feature CALL statement is allowed if the called program does not issue any CICS commands or inhibited COBOL statements mentioned above. Only header is required
TERMINATION STATEMENTS Notes :This is not the way to terminate a CICS program. CICS has a command for that purpose. Nevertheless, COBOL
and VS COBOL II have three statements to conclude programs.
Control must not be allowed to pass beyond the last statement of a CICS Program. STOP RUN in COBOL uses operating system facilities, and therefore, is discouraged. EXIT program is ignored if the program has not been called. CICS RETURN COMMAND and/or GOBACK statement is recommended.
Transactions
An exchange between a terminal and a data base representing an application process. For example, an inquiry or a deposit and balance update
Task
A specific instance of a transaction i.e. a unique unit of work.
Program
Prepared statements compiled or assembled into an executable module of machine instructions.
CONVERSATIONAL TRANSACTION
Program uses a pair of SEND and RECEIVE commands. Program waits until the user responds. Resources are held until the user responds. Very inefficient way of conversing with the user.
PROGRAM PREPARATION
Running the DB2 precompiler first is the preferred method. DB2 precompiler precedes another process, binding, not mentioned here. Output of the DB2 precompiler can serve as input to the translator. Output of the translator will be input to the compiler. Messages or warnings are provided on all the listings. TRANSLATOR recognizes EXEC CICS and EXEC DLI statements. They are commented out and replaced with statements in the appropriate language. Here, COBOL MOVE instructions and a CALL are inserted and passed on to the COBOL compiler.
DB2 Precompiler is supplied by the relational data base managers, DB2 and SQL/DS. It recognizes EXEC SQL statements which it will comment out and replace with in our case. COBOL PERFORM and CALL statements.
Output of the transaction is i/p to the compiler The o/p of the linkage editor is executable. The load module is placed in the CICS online program library. Messages or warnings are provided on all the listings. The compiler listing is or limited use if the translator listing would not process all commands.
COMMON FORMAT
A CICS command consists of a keyword phrase, delimiter, function, options and their argument values. Be careful about periods. Avoid them after END-EXEC. Where you dont really want them. For eg. within an If
The translator will place a period into the generated code if a period follows end-exec.
ARGUMENT VALUES PIC S9(4) comp Halfword binary PIC S9(8) comp Fullword binary PIC X(15) character string constants permitted COBOL data name (Not a constant) eg :01 data area 05 05 Fld 1 Fld 2 Record-area.
data value
name
Paragraph name PIC S9(7) comp 3 Packed decimal BLL cell Usage pointer
RECEIVE COMMAND
EXEC CICS RECEIVE INTO (data area) LENGTH(ml) END-EXEC RECEIVE command is used to receive incoming data from the terminal to which this CICS transaction is associated. A receiving area must be defined in working storage section and has to be specified in the INTO parameter. Length field must be defined in working storage section as a S9(4) comp. It has to be specified in length option.
SEND COMMAND
EXEC CICS SEND FROM (data area) LENGTH(ln) END-EXEC The data to be sent must be stored in working storage section, and this field name has to be specified in the FROM parameter. Length must be specified the same as that of the Receive command.
EXCEPTIONAL CONDITIONS
o o o RESP option Define a full word binary field S9(8) comp in the working storage section as the response field. Place RESP option with the response field in any CICS command. After command execution, check the response code in the response field with DFHRESP (xxxx)where xxxx is NORMALfor normal completion or Any exceptional condition
HANDLE CONDITION
Handle condition command is used to transfer control to the procedure label specified if the exceptional condition, specified occurs. Remains active until the end of program or another handle condition request overrides it.
IGNORE CONDITION
Ignore condition command causes no action to be taken if the condition specified occurs in the programs. Request by the IGNORE CONDITION command is valid until the subsequent HANDLE CONDITION command for the same condition.
NO HANDLE OPTION
If NOHANDLE option is specified in any CICS command, no action will be taken for any exceptional condition occurring during execution of this command. o Eg : EXEC CICS SEND From () Length () NOHANDLE END-EXEC
DELAY COMMAND
used to delay the processing of a task for the specified time interval or until the specified time. FORMAT EXEC CICS DELAY INTERVAL (002000)
TIME (152000) End EXEC Task will be suspended for 20 minutes if INTERVAL is specified or until15:20:00if TIME is specified.
COMMAREA
Passing data via the COMMAREA pseudo conversational task to task Linking program to program
PSEUDO CONVERSATIONAL
Pseudo conversational technique is uses the multiple transaction identifiers(pct entries) and multiple program (pct entries). It performsthe terminal conversation in the following way: A conversational program is logically and physically divided into separte programs after sending a message and before receving the message. For each separate program, a unique cics trasction identifier is assigned. before terminating the program, each program issues the RETURN command with the next transaction identifier which is associated with the next program, unless it is the least return to CICS itself. in this way, a series of terminal conversations can be carried out continuously.
Notes :
The first time commarea is passed, it must begin as an area of storage in the working storage section of the program passing it. o A commarea parameter in the RETURN will pass the area to the program associated with the subsequent transaction. In this case, itself. o The subsequent program (in this case the same program) must define access to all the commarea that was passed to it.
PAYROLL as both the sender and the receiver of the COMMAREA needs the working storage definition to send and the linkage section DFHCOMMAREA to receive. PAYROLL must therefore be able to distinguish between FIRST TIME into the program. When there is no COMMAREA and subsequent times in. Where one exists in the Linkage section. The EIB field, EIBCALEN indicates the length of the commarea.
EIBCALEN
First time into the program no commarea exists, therefore EIBCALEN = 0 While returning the control to CICS the working storage is loaded and this is sent via the commarea parameter in the RETURN Transid. On subsequent entry, commarea exists and is automatically made addressable by CICS in the linkage section of DFHCOMMAREA
The commarea is shared between the two program regains control may changes made to the commarea by the linked program are accessible. The two programs executive under the same task. The working storage section for the linking program is retained. Working storage for the linked program is automatically released after its RETURN command is executed. To pass control from one program to another and then return to the original like executing a subroutine. The link command passes control to another program defined in CICS PPT expecting that the program will return to the linking program instruction following the LINK command. This happens when the linked program issues a RETURN command.
TOPICS
o o o o DIRECT RETRIEVAL VSAM FILE RECORD RELATIONAL TABLE ROW BROWSE VSAM FILE RECORDS SET OF RELATIONAL TABLE WORKS
PROGRAM ORGANIZATION
o o o File attributes are defined in the FCT for each file Files are opened by CICS Immediately after system initialization if specified in the FCT. In response to a file access request from an application if the file is closed In response to a master terminal CEMT request from an operation. Application program is not responsible for open / close of files
RECORD IDENTIFICATION
o o o o o o o RECORD KEY RELATIVE BYTE ADDRESS RELATIVE RECORD NUMBER PARTIAL KEY key of the record to be read is specified in the RIDFLD. for KSDS Key specified can be a full key or partial key If partial key, key length has to be provided RBA (Relative Byte Address) Can also be used instead of actual key value For ESDS RIDFLD contain a 4 byte RBA For RRDS RIDFLD contains 4 Byte binary relative record number.
READ COMMAND
o o READ command with INTO Option. (FULL KEY) Reads the record specified by the full key. The data content of the record is moved into the specified data-area defined in the working storage section. o FORMAT EXEC CICS READ DATASET (name) | FILE (name) INTO (data-area) |SET(ptr-ref) RIDFLD (data-area)
[ LENGTH (data-values) ] END EXEC. DATASET / FILE names the file. It must be defined in FCT. INTO names the field in the working storage section where the data has to be placed. RIDFLD is the key field. LENGTH is half word binary. It indicates maximum length of the record to be read. It is optional.
EXCEPTIONAL CONDITIONS
DUPKEY : If duplicate record is found for the specified key. NOTFND : If the record is not found for the key specified. LENGER R LENGERR : The specified length (in LENGTH OPTION) is shorter than the actual record length. NOTOPEN : When file specified is not open.
The exceptional condition can be trapped using RESP option in the READ command.
ADDRESSABILITY TECHNIQUES
EXEC CICS XCTL PROGRAM (PROGRAM NAME) RESP (EXCEPTION) END-EXEC. IF EXCEPTION = DFHRESP (PGMIDERR) a module given control through the use of a CICS XCTL command will not return to the program that issued the XCTL. The required. program name is character string constant (max 8 characters) The PGMIDERR exception condition occurs when the name is not in the PPT.
LOGICAL LEVELS
The linked to program runs at a new logical level and returns to a logical level back to the linking program. The linking program and its storage area remain available.
Notes :
To quit the repeated execution simply RETURN without the TRANSID option. Any linked program could use the same COMMAREA of the parameters so indicated. The transid & commarea option easy enough to use to make this method practical.
dotted
Linkage Section (prog2) 01 DFHCOMMAREA 05 AREA2 PIC X(200) 1ST Program COMMAREA Length 100 Data violation as 2nd Program (receives) tries to move 200 char
ADDRESSABILITY
DFHCOMMAREA & DFHEIBLK : Addressable automatically by CICS Dynamically acquired storage : Addressable by program Not necessary to always do a EXEC CICS GETMAIN explicitly
Record can be written sequentially. Records can be of variable length format Several tasks can write to the same TDQ but only one task can read from TDQ.
Intra Partition TDQ is used in application such as Interface among CICS transaction. Applicati on program 1 TDQ Appl . Pgm 2 report Automatic task Initiation (ATI) Message routing Message Broad cast.
EXCEPTIONAL CONDITIONS
1. Special handling required LENGERR length specified is greater than the maximum record length specified in DCT 2. Qzero Destination empties or end of TDQ error Qlderr The dest ld specified cannot be found in DCT.
TEMPORARY STORAGE
TSQ is a queue of stored records. Created & deleted dynamically by application program. Used as a scratch pad Queue ID is of length 1-8 bytes TSQ is of variable length Records can be stored in main or auxiliary storage The records once written remains accessible until the entire TSQ is deleted Records can be read sequentially or directly Records can be re-read & updated.
WRITEQ TS
To write or re-write a record in TSQ EXEC CICS WRITEQ TS
QUEUE (NAME) LENGTH (DATA-VALUE) [ITEM (DATA-AREA) [REWRITE] [MAIN | AUXILIARY] END-EXEC. ITEM If this option is coded CICS write return the item number assigned to the record just written. REWRITE is used to rewrite the record identified by ITEM. Main/ Auxiliary To specify the storage medium. Will be stored in main if auxiliary storage not supported.
READQ TS
Can be used to read records either sequentially or directly.Syntax EXEC CICS READQ TS QUEUE (NAME) INTO (DATA AREA) LENGTH (DATA-VALUE) [ITEM (DATA-VALUE) | NEXT] [NUMREC (DATA-AREA)] END-EXEC. NEXT to retrieve the next logical record in the TSQ. mutually exclusive to the item option NUMREC the data area is defined as PIC 9(4) comp. to find the Total no. of records in the TSQ. Item for direct access specify the item no of the record.
DELETEQ TS of TSQ
EXEC CICS DELETEQ TS QUEUE (NAME) END-EXEC. All records is TSQ are deleted. All associated storage is released.
EXCEPTIONAL CONDITIONS
o o Special handling required Itemerr Item number specified is not in the range of entry number assigned for the Queue. Lengerr Length specified is greater than the maximum record length. error Q iderr specified is Queue id not found.
CECI (Command Level Interpreter) is a CICS supplied transaction which performs syntax checking of a CICS command. If the syntax is satisfied, it will execute the command. CEBR (Temporary Storage Browse) is a CICS supplied transaction which browses Temporary Storage Queue (TSQ). CEDF is a CICS supplied transaction which monitors the execution of an application program as an interactive debugging aid.
EXCEPTION HANDLING
CICS to respond to exceptional conditions in one of three ways: RESP option: The RESP option can be specified in any CICS command. Its function is similar to the return code in the batch program. o Define a fullword binary field (S9(8)COMP) in the working storage section as a response field. Place the RESP option with the response filed in a command. After command execution, check the response code in the response field with DFHRESP (xxxx), where xxxx is the NORMAL - Any exceptional condition HANDLE CONDITION This command is used to transfer control to the procedure label specified if the exceptional condition specified occurs. IGNORE CONDITION This command causes no action to be taken if the condition specified occurs in the program.
EXEC CICS HANDLE CONDITION Condition (Label) [Condition (Label)] [Error (Label)] END-EXEC.
or
EXEC CICS IGNORE CONDITION Condition [Condition] END-EXEC. ABEND CODE
If an exceptional condition occurs during execution of a CICS application program and if the program does not check the exceptional condition, CICS may continue executing the program or terminate abnormally the execution of the program, depending on the exceptional condition and the command involved.
indicates a duplicate key (DUPKEY) condition. AEIN indicates a duplicatebrecord (DUPREC) condition. AEID indicates an End of file condition. AEIS indicates that a file is not open (NOTOPEN)
AEIP indicates an invalid request condition (INVREQ) AEY7 indicates that you are not authorised to use a resource (NOTAUTH) AICA This abend usually occurs if your program is looping. There are CICS parameters that determine how long a task can run without giving up control. The ICVR parameter in the CICS SIT table can be used to specify a value for all tasks running in CICS, or you can specify a RUNAWAY value when you define a transaction . If a program is looping then you may not get an AICA abend, because the timer can be reset when certain events occur, eg some EXEC CICS commands may reset the timer to zero. ATCH and ATCI These abends indicates that the task was purged. The task may have been purged by someone issuing a CEMT command to purge the task, or by CICS because the Deadlock timeout limit has been exceeded or because there was not enough virtual storage available to run all the tasks in CICS (Short on Storage) APCT A program was not found or was disabled. Check the transaction definition to see if the program name was misspelled. Check that the program is enabled. Check that the program is in an appropriate Load Library (ie one defined to the current CICS system). AKCP and AKCT These abends indicate that a timeout of the task occurred. This may be due to a deadlock. AFCA A dataset could not be accessed because it was disabled. ABM0 The specified map was not found in the specified mapset. Check that you have not misspelled the map name. The Execute Interface Block (EIBLK) contains a variable called EIBFN.This contains a value that tells you what CICS command was last executed. This value can be displayed as part of an error message, to aid in the debugging of your code or when an exception condition occurs The values for EIBFN are show below. Code Command 0202 ADDRESS 0204 HANDLE CONDITION
0206 HANDLE AID 0208 ASSIGN 020A IGNORE CONDITION 020C PUSH 020E POP 0210 ADDRESS SET 0402 RECEIVE 0404 SEND 0406 CONVERSE 0408 ISSUE EODS 040A ISSUE COPY 040C WAIT TERMINAL 040E ISSUE LOAD 0410 WAIT SIGNAL 0412 ISSUE RESET 0414 ISSUE DISCONNECT 0416 ISSUE ENDOUTPUT 0418 ISSUE ERASEAUP 041A ISSUE ENDFILE 041C ISSUE PRINT 041E ISSUE SIGNAL 0420 ALLOCATE 0422 FREE 0424 POINT 0426 BUILD ATTACH 0428 EXTRACT ATTACH 042A EXTRACT TCT 042C WAIT CONVID 042E EXTRACT PROCESS 0430 ISSUE ABEND 0432 CONNECT PROCESS 0434 ISSUE CONFIRMATION 0436 ISSUE ERROR 0438 ISSUE PREPARE 043A ISSUE PASS 043C EXTRACT LOGONMSG 043E EXTRACT ATTRIBUTES 0602 READ 0604 WRITE 0606 REWRITE 0608 DELETE 060A UNLOCK 060C STARTBR 060E READNEXT 0610 READPREV 0612 ENDBR 0614 RESETBR 0802 WRITEQ TD 0804 READQ TD 0806 DELETEQ TD 0A02 WRITEQ TS 0A04 READQ TS 0A06 DELETEQ TS 0C02 GETMAIN
0C04 FREEMAIN 0E02 LINK 0E04 XCTL 0E06 LOAD 0E08 RETURN 0E0A RELEASE 0E0C ABEND 0E0E HANDLE ABEND 1002 ASKTIME 1004 DELAY 1006 POST 1008 START 100A RETRIEVE 100C CANCEL 1202 WAIT EVENT 1204 ENQ 1206 DEQ 1208 SUSPEND 1402 WRITE JOURNALNUM 1404 WAIT JOURNALNUM 1602 SYNCPOINT 1802 RECEIVE MAP 1804 SEND MAP 1806 SEND TEXT 1808 SEND PAGE 180A PURGE MESSAGE 180C ROUTE 180E RECEIVE PARTN 1810 SEND PARTNSET 1812 SEND CONTROL 1C02 DUMP 1E02 ISSUE ADD 1E04 ISSUE ERASE 1E06 ISSUE REPLACE 1E08 ISSUE ABORT 1E0A ISSUE QUERY 1E0C ISSUE END 1E0E ISSUE RECEIVE 1E10 ISSUE NOTE 1E12 ISSUE WAIT 1E14 ISSUE SEND 2002 BIF DEEDIT 4802 ENTER TRACENUM 4804 MONITOR 4A02 ASKTIME ABSTIME 4A04 FORMATTIME 5602 SPOOLOPEN 5604 SPOOLREAD 5606 SPOOLWRITE 5610 SPOOLCLOSE 5E06 CHANGE TASK 5E22 WAIT EXTERNAL 5E32 WAITCICS 6A02 QUERY SECURITY
6C02 WRITE OPERATOR 6C12 ISSUE DFHWTO 7402 SIGNON 7404 SIGNOFF 7406 VERIFY PASSWORD 7408 CHANGE PASSWORD 7E02 DUMP TRANSACTION
CICS FAQs:-
CICS FAQS
Question: what is difference between call and link ? Answer: In case of call , whenever you do changes to the called program you need to compile the calling program also. In case of link , it is not needed . Question: what are the differences between dfhcommarea and tsq ? Answer: both are used to save data among tasks. but 1. commarea is private to that transaction only . like every transaction has its own commarea created by cics as soon as the transaction is initiated . however tsq , if qid is known can be accessed by other transactions also 2. commarea length is s9(4) comp ie 65k . but tsq can have any length.3. commarea is available only during the transaction is running. tsq if created with auxiliary option resides in aux memory and available even if main memory crashes.4.normally commarea is used to tranfer data from one task to another while tsq is used widely within the task as a scratch pad. Question: What is Communication Area? Answer: Communication Area is used to pass data between the programmer between the task. Question: Which of the following statements correctly describe the syntax of CICS command language? Answer: 1. If an EXEC CICS command must be continued onto a second line a hyphen (-) must be coded in column 7 of the continued line. 2. If an EXEC CICS command must be continued onto a second line an X must be coded in column 72 of each line to be continued.
3. An EXEC CICS command CANNOT be coded within a COBOL IF statement,between the IF command and the period (.) ending it. 4. The END-EXEC delimiter is optional and never needs to be placed at the end of a CICS command. 5. The options specified within an EXEC CICS command can be in any order. For example EXEC CICS SEND FROM(MSG1) LENGTH(30) END-EXEC can also be coded EXEC CICS SEND LENGTH(30) FROM(MSG1) END-EXEC Question: .A CICS program ABENDS with an ASRA ABEND code. What is its meaning? Answer: 1. A link was issued to a program whose name does not exist in the PPT (Program Processing Table). 2. A program attempted to use a map that is not defined in the PCT (Program Control Table). 3. A security violation has occurred. The operator is not defined with the proper authority in the SNT (Sign-on Table) to use a particular file. 4. A program interrupt (0C0 or 0C1 or 0C2 or ) has occurred in a CICS program. 5. An I/O error has occurred when attempting to use a VSAM file from a CICS program Question: Which of the following commands, when issued by 2 different programs running at the same time, will prevent simultaneous use of resource SINGLE? Answer: 1. EXEC CICS PROTECT RESOURCE(SINGLE) LENGTH(6) END-EXEC. 2. EXEC CICS HOLD RESOURCE(SINGLE) LENGTH(6) END-EXEC. 3. EXEC CICS TASK SINGLE(SINGLE) LENGTH(6) END-EXEC. 4. EXEC CICS EXCLUSIVE RESOURCE(SINGLE) LENGTH(6) END-EXEC. Question: How can you accomplish braykpoint in intertest? Answer: U-for uncondishional braykpoint, C-for condishional braykpoint,and A-for automatic braykpoint Question: how many ways are there for initiating a transaction?what are they? Answer: There are six ways in initiating a transaction.they are as follows. 1. embedding four character transid on the top left most corner of the screen. 2. making use of EXEC CICS START TRANSID ( ) 3. making use of EXEC CICS RETURN TRANSID ( ) 4. By defining the transid in DCT ( destination control table) to enable ATI (AUTOMATIC TASK INITIATION) 5. Making use of PLT ( program list table) 6. By associating four character transid in PCT (program control table) Question: which type of TDQ is read destructive? Answer: intrapartition tdq is read destructive. extrapartition tdq is not read destrctive. Question: The error code aeiv? Answer: this is the error code for length,if length of the source data is more than the receiving field,this error will occur.this is the correct answer,previously i mentioned it as program id error.sorry for the wrong information. Question: WHAT U MEAN BY AEIV ? Answer: THIS IS THE ERROR CODE GIVEN BY THE SYSTEM ,IT MEANS PROGRAM ID ERROR. Question: WHAT IS THE SIZE OF COMMAREA Answer: THE DEFAULT COMMAREA SIZE IS 65K.
Question: What is ASRAABEND in CICS? Answer: It occurs when program interuption takes place.e.g.: when alphanumeric string moved to numeric data itemOR when arithmetic calculations performed on nonnumeric data itemOR when an attempt made to read an occurance of a table beyond the defind occurances. Question:What is a two Phase commit in CICS? Answer: This occurs when a programmer Issues a Exec CICS Syncpoint command. this is called two phase because CICS will first commit changes to the resources under its control like VSAM files. and the DB2 changes are committed. Usually CICS signals Db2 to complete the next phase and release all the locks. Question: Answer to ANONs question, diference between TSQ & TDQ Answer: TDQ is read destructive, TSQ is not. TSQ can be created dynamically, TDQ cannot be created dynamically. TSQ is temporary in nature (i:e it will be deleted when the program finishes execution, unless it is made permanent by making a entry in the Temporary Storage Table), TDQ is not. Hope this will suffice Question: What is ENQ in CICS? Answer: If any one want to restrict Trans-Id to single user, enter trans-id with ENQ. It wont allow any one else to use the same trans-id. Question: In SYMBOLIC Cursor Positioning after moving -1 to the length field also the cursor is not positioned in that particular field.Give reasons? Answer: You have to explicitly specify the word CURSOR between your EXEC CICS and END-EXEC in the program. Question: What does EIB mean? Answer: The EIB is the EXECUTIVE INTERFACE BLOCK. It is not the EXECUTE INTERFACE BLOCK. All TP monitors or transaction processors are know as EXECUTIVEs as they carry out process on behalf of a program module. CICS and DB2 are excutives. Question: How many exceptional condition can be given in a HANDLE CONDITION? Answer: Max. of 12 exceptional conditions can be given in a single HANDLE CONDITION. Question: What command do you issue to delete a record in a transient data queue ? Answer: READQ TD, the read is destructive. Yes it is correct but there is a restriction.U can deletethe records sequentially.. For example if one want to delete 10 th record directly it is not possible with this.. Question: How do you access the records randomly in TSQ ? Answer: By specifying the ITEM option Question: What command do you issue to delete a record in a transient data queue ? Answer: READQ TD, the read is destructive. Question: WHAT ARE DIFFERENT WAYS OF INITIATING TRANSACTION IN CICS Answer: WE CAN INITIATE CICS TRANSACTION 1. BY GIVING TRANSACTION ID 2. BY GIVING CICS START COMMAND 3. AUTOMATIC TASK INITIATION. Question: What is the difference between LINK and XCTL ? Answer: The XCTL command passes control to another program, but the resources requested by the first program may still be allocated. A task does not end until a RETURN statement is executed. While in LINK command, program control resumes its instruction following the LINK parameter. The disadvantage of LINK is that it requires that both the calling program and the called program remain in main memory even though both are no longer needed. Question: What is the difference between CICS Program Control Table (PCT) and CICS Processing Program Table (PPT) ? Answer: PCT contains a list of valid transaction ID. Each transaction ID is paired with the name of the program ,CICS will load and execute when the transaction is invoked. On the other hand, PPT indicates each programs location which pertains to a storage address if the program has already been loaded or a disk location if the program hasnt been loaded. PPT will also be used to determine whether it will load a new copy of the program when the transaction is invoked. Question: What are the 3 common ways to create maps? Answer: The first way is to code a physical map and then code a matching symbolic map in your COBOL program. The
second way to create a physical map along with a matching symbolic map is to code only the physical map using the &SYSPARM option, CICS will automatically create a member in a COPY library. And the third way is to use a map generator such as SDF (Screen Definition Facility) Question: What is Quasi-reentrancy? Answer: There are times when many users are concurrently using the same program, this is what we call MultiThreading. For example, 50 users are using program A, CICS will provide 50 Working storage for that program but one Procedure Division. And this technique is known as quasi-reentrancy Question: What is the difference between a physical BMS mapset and a logical BMS mapset? Answer: The physical mapset is a load module used to map the data to the screen at execution time. The symbolic map is the actual copybook member used in the program to reference the input and output fields on the screen. Question: How To Set MDT(Modified Data Tag) Thru Application Program?(Dynamically). Answer: You have to move the following macro DFHBMFSE to the Attribute field of that particular Variable. Question: What CICS facilities can you use to save data between the transactions? Answer: COMMONAREA, TSQ & TDQ. Question: How would you release control of the record in a READ for UPDATE? Answer: By issuing a REWRITE,DELETE, or UNLOCK command or by ending the task. Question: How would you release control of the record in a READ for UPDATE? Answer: By issuing a REWRITE,DELETE, or UNLOCK command or by ending the task. Question: What is the difference between a RETURN with TRANSID and XCTL ?For example prog. A is issuing REUTRN with TRANSID to prog B. Prog A. is issuing XCTL to prog B. Answer: In RETURN with TRANSID the control goes to the CICS region and the user have to transfer the control to prog. B by pressing any of the AID KEYS.In XCTL the control is directly transfer to prog. B. Question: What is the maximum number of exceptions that can be specified with a single HANDLE CONDITION command in CICS ? Answer: SIXTEEN (16) Question: WHAT WILL BE THE LENGTH OF THE EIBCALEN ,IF THE TRANSACTION IS USED TO CICS FIRST TIME? Answer: THE LENGTH WILL BE 0(ZERO) . Question: WHAT IS DFHEIBLK? Answer: DFHEIBLK is Execute Interface Block. It is placed in the linkage section automatically by CICS translator program. It must be the first entry in linkage section. CICS places values prior to giving control to the program and we can find almost any information about our transaction. Question: What is the difference between the XCTL and LINK commands? Answer: The LINK command anticipates return of control to the calling program, theXCTL command does not. Return to the calling program will be the result of the CICS RETURN command, specifying TRANSID(name of the calling program). Question: What CICS command would you use to read a VSAM KSDS sequentially in ascending order? Answer: First issue a STARTBR(start browse), which will position the browse at the desired record. Retrieve records by using subsequent READNEXT commands. Indicate the end of sequential processing with the ENDBR command. If the generic key is specified in the STARTBR command positioning in the file will be before the first record satisfying the generic key.For reading in descending order use the READPREV instead ofREADNEXT. Question: What is the difference between pseudo-conversational and conversational? Answer: Pseudo-conversational will start a new task for each input. By coding a CICS RETURN command specifying TRANSID(itself). Conversational will have an active task during the duration of the data entry. Question: What is the COMMAREA(communications area)? Answer: An area used to transfer data between diffrent programs or between subsequent executions of the same program. Needs to be defined in the Linkage Section.
DB2 Tutorial :-
Introduction to Databases
What is data?
A representation of facts or instruction in a form suitable for communication.
What is a database?
It is a repository for stored data.
Object-Oriented Model
HIERARCHICAL MODEL
Top down structure resembling an upside-down tree. Parent child relationship First logical database Model Available on most of the Mainframe computers Examples: IMS
NETWORK MODEL
Does not distinguish between parent and child. Any record type can be associated with any number of arbitrary record types Enhanced to overcome limitations of other models but in reality there is minimal difference due to frequent enhancement Example: IDMS
RELATIONAL MODEL
Data stored in the form of table consists of multiple rows and columns. Examples: DB2,ORACLE,SYBASE
OBJECT-ORIENTED MODEL
Data attributes and methods that operate on those attributes are encapsulated instructions called objects.
Types of Integrity
Entity Integrity Referential Integrity Domain Integrity
Entity Integrity
Is a state where no column that is part of a primary key can have a null value.
Referential Integrity
Is a state where every foreign key in the first table must either match a primary key value in the second table or must be wholly null.
Domain Integrity
Integrating of information allowed in column.
Each order relates to only one customer (one-to-one) Many orders can contain many products (many-to-many) A customer can place any number of orders ( one-to-many) In last example customer,order & product are called entities An entities may transform into tables. The unique identity for information stored in an entity is called a primary key Attributes which define the characteristics of the table.
DB2
OBJECTS
Stogroup(Storage group) Database Table Space Table View Index
Database
A collection of logically related objects like table spaces, index spaces,tables etc. Not a physical kind of object, may occupy more than one disk space. A STOGROUP & BUFFER POOL must be defined for each database. In a given database, all the spaces need not have the same STOGROUP.
TABLE SPACES
o o o Logical address space on secondary storage to hold one or more tables. It is the storage unit for recovery and reorganizing purpose Three types of table spaces are : Simple Partitioned Segmented
Depending on application, storing more than one tables might enable faster retrieval for joins using these tables. Usually only one table is preferred. This is because a single page can contain rows from all tables defined in the database.
TABLES
A table is a collection of rows and columns. The data is stored on magnetic disks in a series of TABLES. Each COLUMN contains some specific information about suppliers and each ROW contains all the information about a particular supplier. For example SUPPLIER table looks like :
STATUS 20 30 10
Views can be very practical ways of simplifying queries by reducing the number of different tables. Views can also hide sensitive data from users who dont need access to it. CREATE VIEW EMP_VIEW AS EMPNO,NAME,DEPT,JOB FROM
SELECT
EMP
SYNONYMS
Synonym is like a nick name to a table name and when no longer needed it can be dropped. Synonym access is specific to the user who has created it.
SQL TYPES(Others)
Static or Dynamic SQL Embedded or Stand-alone SQL
Any SELECT statement must specify a table If the table belongs to another user, you may have to prefix the table name with the other users ID.
Using the * to indicate all columns should be displayed is inefficient if you dont need to see all the columns. You can put the columns in the order you want them. It is better to specify just those column you want.
Using ORDER BY keyword to your query SQL automatically orders data in ascending order if you have any ORDER BY statement in your query. If you want your data in descending order, use the DESC keyword. SELECT STATUS FROM SUPPLIERS ORDER
BY STATUS DESC
BYSTATUS,SNAME
You can link as many search expression as you want using AND and OR. Using both operator together , searched expression linked by AND are paired up first.Parentheses can be used to force expression to be paired together.
CONDITION equal to greater than less than greater than or equal to lesser than or equal to less than or greater than containing certain characters within a range of values one of a set of values
IN
Lets you retrieve data from each row whose columns has a value equal to one of the several listed values. Example: WHERE STATUS IN (20,10,30) Any row with STATUS column value of 20,10, 30 is selected. Each character value must be in quotes. Values are separated by comma & values list is enclosed in parenthesis.
BETWEEN
Lets you retrieve data from each row whose columns has a value with two limits. Example: WHERE STATUS BETWEEN 10 AND 30
Any row with STATUS column value of 10 thru 30 is selected. It can be used for both numeric and character values. The two values must be separated by AND, the lower value must be the first value.
LIKE
Lets you retrieve data from each row whose columns has a value similar to the value specified in the WHERE CLAUSE. Example: WHERE SNAME LIKE B%C Any row with name column beginning with B followed by ANY VALUE of ANY LENGTH, and ending with C is selected. A % represents any value of any length,where as an underscore _ represents any single character LIKE cant use for any numeric column.
What is NULL?
A NULL is a column value that does not exists. It is not a blank, not is it zero it is a non-value. The columns must predefined to the DBMS as a column that may contain NULL values.
ARITHMETRIC EXPRESSIONS
An arithmetic expression is a calculation using numeric values and one or more of the arithmetic operators :addition (+), subtraction (-), multiplication (*), and division (/). Example: SELECT SALARY + COMM,NAME,DEPT Arithmetic expressions can also be used in a WHERE clause: WHERE SALARY + COMM >5000.00
You can combine column names and constants in arithmetic expressions. 1998 JOIN_YR, 1.0*SALARY
BUILT IN FUNCTION
SUM MAX MIN AVG COUNT(*) COUNT(DISTINCT col name)
SUM
Calculate the total value for a given column or arithmetic expression SELECT SUM(SALARY) FROM EMP
AVG
Display the average of all non-NULL columns SELECT AVG(SALARY) FROM EMP AVG disregard any rows with NULLs in any column involved in the averaging expression Integer columns are not rounded, so result may be inaccurate. To convert an integer column to a decimal column multiply by 1.0 as part of the AVG expression. AVG(1.0 * STATUS)
COUNT(*)
It counts all the rows selected by a query SELECT COUNT(*) FROM SUPPLIERS
When you request a built-in summary functions, SQL goes through several steps to reach a result. First, all the rows and columns are selected. This intermediate result is kept in a temporary table. Next, the system process your GROUP BY request, creating a temporary table for each GROUP and putting the appropriate rows in each table. Then the built-in functions are calculated. If, for example you requested an AVG, then the average for each temporary sub group is calculated.
GROUP BY
GROUP BY outputs a summary table one line for each group. GROUP BY can only be used in conjunction with built-in functions. GROUP BY follows FROM and WHERE and precedes ORDER BY Example: SELECT DEPT, MAX(SALARY) FROM EMP GOUP
BY DEPT
It will produce a table listing the maximum salary value for each department.
HAVING
It is similar in function to the WHERE clause Its purpose is to further define a group specified in the GROUP BY statementSELECT DEPT, AVG(SALARY) FROM EMP GROUP
BY DEPT HAVINGCOUNT(*)>3
HAVING can only be used in conjunction with GROUP BY HAVING must immediately follow the GROUP BY clause HAVING can only compare built-in functions not individual columns
JOINING
Joining tables involves matching the rows of one table with related rows of another table to produce a table consisting of rows with columns from both the original tables.
JOINING COLUMN
It is a column that is common to all the tables being joined and contains the row values that tie one table to next.
MERGING
Merging tables also involves combining data from two tables, but the rows are not joined together.
DATA TYPES
Data type depends on the nature of the data itself and will always be one of two types NUMERIC or CHARACTER o Types of CHARACTER column CHAR Allows any values to be entered in the column. All entries are the same length VARCHAR Allows any values to be entered in the column. All entries are the varying length o Types of NUMERIC columns INTEGER For very large integers up to 2,147,483,647 SMALLINT For small integer up to 99999 Table Space
o o
DECIMAL For numbers with a fixed number of decimal places after the decimal point. The number can have a total of 15 digits FLOAT -For very large numbers with an undetermined number of decimal places after the decimal point Types of DATE/TIME columns DATE Dates are stored in YYYYMMDD format TIME Times are stored on a 24-hour clock in HHMMSS format TIMESTAMP TIMESTAMP columns contain both date and time information, with the time value accurate to the millisecond.
PRIVILEGES
GRANT ALL ON TABLE EMP TO PUBLIC REVOKE ALL ON EMP TO PUBLIC
DROP
o o o When you no longer need a TABLE, VIEW, or SYNONYM you can DROP them. DROP TABLE SUPPLIER DROP VIEW EMP_VIEW DROP SYNONYM S
INSERTING A TABLE
There must be one value for each column Separate values with commas Put character values in single quotes Numeric values do not require quotes
If you want enter the values in a different order, there is an alternative way of inserting a row, by listing the columns along with their assigned values o INSERT INTO SUPPLIER (S#,STATUS,SNAME) VALUES(S1,30,VAST)
UPDATE
SQL provides two commands for updating row values UPDATE and SET. UPDATE tells SQL which table you want to update and SET provides the name of the column to update and the new value for the column. You tell SQL which row to update with a WHERE clause can be very specific, so that a single row gets changed, or it can be very general, so that many rows get updated. o o <B>UPDATE SUPPLIER SET STATUS = 40 WHERE S# = S1 UPDATE EMP SET SALARY = SALARY + SALARY *.01
DELETE
Using the DELETE command you can delete rows and using WHERE clause you can specify which rows you want to delete. o DELETE FROM SUPPLIER WHERE S# = S1
Complex SQLs
o One terms a SQL to be complex when data that is to be retrieved comes from more than one table. SQL provides two ways of coding a complex SQL Subqueries and Join
SUB QUERIES
Nested select statements. Specified using the IN or NOT IN predicate, equality or non-equality predicate and comparative operator. When using the equality, non-equality or comparative operators the inner query should return only a single value. Nested loop statements gives the user flexibility for querying multiple tables. A specialized form is a correlated sub query. It works on top-bottom-top fashion. Non correlated sub query works in bottom to top fashion.
JOINS
OUTER JOIN INNER JOIN
OUTER JOIN
For one or more tables being joined both matching and the non-matching rows are returned. Duplicate columns may be eliminated. Non-matching columns will have nulls.
INNER JOIN
Here there is a possibility one or more of the rows from either or both tables being joined will not be included in the table that results from the join operation
Program Preparation
o o Precompile Compile & Link Bind Package Plan
Precompile
Searches all the SQL statements and DB2 related INCLUDE members and comments out every SQL statement in the program. The SQL statements are replaced by a CALL to the DB2 runtime interface module along with parameter. All SQL statements are extracted and put in a DBRM. Places a time stamp in the modified source and the DBRM so that these are tied. All DB2 related INCLUDE statements must be placed between EXEC SQL & END-EXEC key words for the precompiler to recognize them.
Bind
A type of compiler for SQL statement. It reads the SQL statements from the DBRM and produces a mechanism to access data as directed by the SQL statements being bound. Checks syntax, check for correctness of table & column definitions against the catalog information & performs authorization validation.
Package
It is a single bound DBRM with optimized access paths. It also contains a location identifier a collection identifier and a package identifier. A package can have multiple versions , each with its own version identifier.
Advantages of Package
Reduced bind time. Versioning. Provides remote data access. Can specify bind options at the programmer level.
Plan
o o An application plan contains one or both of the following elements A list of package names. The bound form of SQL statements taken from one or more DBRM. Every DB2 application requires an application plan. Plans are created using the DB2 sub commands BIND PLAN.
DB2 Optimizer
Analyzes the SQL statements and determines the most efficient way to access data, gives physical data independence. It evaluates the following factors: CPU cost, I/O cost, DB2 catalogue statistics & the SQL statements It estimate CPU time , cost involved in applying predicates traversing pages & sorting. It estimates the cost of physically retrieving and writing data.
Host Variables
These are variables defined in the host language to use the predicates of a DB2 table. These are referenced in the SQL statement. A means of moving data from and to DB2 tables. DCLGEN produces host variables the same as the columns of the tables.
DCLGEN
Issued for a single table. Prepares the structures of the table in a COBOL copy book. The copy book contains a SQL DECLARE TABLE statement along with a working storage host variable definition for the table.
SQLCA
An SQLCA is a structure or collection of variables that is updated after each SQL statement executes. An application program that contains executable SQL statements must provide exactly one SQLCA.
CURSOR
Used when more than one row are to be selected. Can be used for modifying data using FOR
UPDATE OF clause.
DECLARE:
EXEC SQL DECLARE empcur CURSOR FOR SELECT empno, ename, dept, job FROM emp WHERE dept=D11 FOR UPDATE OF job END-EXEC.
DB2 LOCKING
Locking is used to provide multiple user access to the same system. DB2 uses locking services provided by an MVS subsystem called IMS Resource Locking Manager(IRLM).
Catalogue Tables
Repository for all DB2 objects contains 43 tables Each table maintains data about an aspects of the DB2 environment The data refers to information about table space, tables, indexes etc SYSIBM.SYSTABLES, SYSIBM.SYSINDEXS, SYSIBM.SYSCOLUMNS etc
DB2 Utilities:-
UTILITIES
CHECK COPY MERGECOPY RECOVER LOAD REORG
RUNSTATS EXPLAIN
CHECK
Checks the integrity of DB2 data structures Checks the referential integrity between two tables and also checks DB2 indexes for consistency. Can delete invalid rows and copies them to a exception table.
COPY
Used to create an image copy for the complete table space or a portion of the table space- full image copy or incremental image copy. Every successful exception of COPY utility places in the table, SYSIBM.SYSCOPY, at least one row that indicates the status of the image copy.
MERGECOPY
The MERGECOPY utility combines multiple incremented image copy data sets into a new full or incremental image copy dataset.
RECOVER
Restore Db2 table spaces and indexes to a specific instance. Data can be recovered for a single page, pages that contain I/O errors, a single partition or an entire tablespace. Standard unit of recovery is table space.
LOAD
To accomplish bulk inserts into DB2 table Can replace the current data append to it If a job terminates in any phase of LOAD REPLACE, the utility has to be terminated and rerun
REORG
To reorganize DB2 tables and indexes and there by improving their efficiency of access re-clusters data, resets free space to the amount specified in the create DDL ,statement and deletes and redefines underlying VSAM datasets for stogroup defined objects.
EXPLAIN
Explain can be used to obtain the details about the access paths chosen by the DB2 optimizer for SQL statements. Used specifically for performance monitoring. When EXPLAIN is requested the access paths that the DB2 chooses are put in coded format into the table PLAN_TABLE, which is created in the default database by the user. The other method is specifying EXPLAIN YES with BIND command The PLAN_TABLE is to be queried to get the required information Since the EXPLAIN results are dependent on the DB2 catalogue, it is better to run RUNSTAT before running EXPLAIN.
DB2 FAQS
1. How would you find out the total number of rows in a table? Use SELECT COUNT(*)
1. How do you select a row using indexes? Specify the indexed columns in the WHERE clause.
1. What are aggregate functions? Built-in mathematical functions for use in SELECT clause.
1. How do you find the maximum value in a column? Use SELECT MAX()
1. My SQL statement SELECT AVG(SALARY) FROM EMP yields inaccurate results. Why? Because SALARY is not declared to have NULLs and the employees for whom the salary is not known are also counted. 1. How do you retrieve the first 5 characters of FIRSTNAME column of EMP table? SELECT SUBSTR(FIRSTNAME,1,5) FROM EMP;
1. How do you concatenate the FIRSTNAME and LASTNAME from EMP table to give a complete name? SELECT FIRSTNAME LASTNAME FROM EMP;
1. What is the use of VALUE function? Avoid -ve SQLCODEs by handling nulls and zeroes in computations Substitute a numeric value for any nulls used in computation
1. What isUNION,UNION ALL? UNION : eliminates duplicates UNION ALL: retains duplicates Both these are used to combine the results of different SELECT statements. 1. Suppose I have five SQL SELECT statements connected by UNION/UNION ALL, how many times should I specifyUNIONto eliminate the duplicate rows? Once.
1. In the WHERE clause what is BETWEEN and IN? BETWEEN supplies a range of values while IN supplies a list of values.
1. What is LIKE used for in WHERE clause? What are the wildcard characters? LIKE is used for partial string matches. % ( for a string of any character ) and _ (for any single character ) are the two wild card characters. 1. When do you use a LIKE statement?
To do partial search e.g. to search employee by name, you need not specify the complete name; using LIKE, you can search for partial string matches.
1. What is the meaning of underscore ( _ ) in the LIKE statement? Match for any single character.
1. What do you accomplish by GROUP BY HAVING clause? GROUP BY partitions the selected rows on the distinct values of the column on which you group by. HAVING selects GROUPs which match the criteria specified
1. Consider the employee table with column PROJECT nullable. How can you get a list of employees who are not assigned to any project? SELECT EMPNO FROM EMP WHERE PROJECT IS NULL; 1. What is the result of this query if no rows are selected: SELECT SUM(SALARY) FROM EMP WHERE QUAL=MSC; NULL 1. Why SELECT * is not preferred in embedded SQL programs? For three reasons:
1. If the table structure is changed ( a field is added ), the program will have to be modified. 2. Program might retrieve the columns which it might not use, leading on I/O over head. 3. The chance of an index only scan is lost. 4. What are correlated sub queries? A sub query in which the inner ( nested ) query refers back to the table in the outer query. Correlated sub queries must be evaluated for each qualified row of the outer query that is referred to. 1. What is a cursor? why should it be used? Cursor is a programming device that allows the SELECT to find a set of rows but return them one at a time. Cursor should be used because the host language can deal with only one row at a time.
1. How would you retrieve rows from a DB2 table in embedded SQL? Either by using the single row SELECT statements, or by using the CURSOR.
1. Apart from cursor, what other ways are available to you to retrieve a row from a table in embedded SQL? Single row SELECTs.
1. How do you specify and use a cursor in a COBOL program? Use DECLARE CURSOR statement either in working storage or in procedure division (before open cursor), to specify the SELECT statement. Then use OPEN, FETCH rows in a loop and finally CLOSE.
1. What happens when you say OPEN CURSOR? If there is an ORDER BY clause, rows are fetched, sorted and made available for the FETCH statement. Other wise simply the cursor is placed on the first row. 1. Is DECLARE CURSOR executable? No.
1. Can you have more than one cursor open at any one time in a program? Yes.
1. How do you leave the cursor open after issuing a COMMIT? (for DB2 2.3 or above only ) Use WITH HOLD option in DECLARE CURSOR statement. But, it has not effect in psuedoconversational CICS programs. 1. Give the COBOL definition of a VARCHAR field. 10 REMARKS. 49 REMARKS-LEN PIC S9(4) USAGE COMP. A VARCHAR column REMARKS would be defined as follows:
1. What is the physical storage length of each of the following DB2 data types: DATE, TIME, TIMESTAMP?
1. What is DCLGEN? DeCLarations GENerator: used to create the host language copybooks for the table definitions. Also creates the DECLARE table. 1. What is JOIN and different types of JOIN. The ability to join rows and combine data from two or more tables is one of the most powerful features of relational system. Three types of joins: 1. Equi-join 2. Non-equijoin 3. self-join 4. Can I alter a table (e.g. adding a column) when other user is selecting some Columns or updating some columns from the same table? yes possible. until the updation or selection is committed db2 table will not be restructured. new column definition will be there but it will not be included until all the tasks on the table are committed. 1. What are the different methods of accessing db2 from tso? There are three ways in establishing tso/db2 connection
1. SPUFI 2. QMF 3. CATALOG VISIBILITY 4. How is the connection established between TSO & DB2? A thread between TSO & DB2 is established while attempting to make Connection between tso & db2. 1. What is sqlcode -922? Authorization failure
1. How do you do the EXPLAIN of a dynamic SQL statement? Use SPUFI or QMF to EXPLAIN the dynamic SQL statement Include EXPLAIN command in the embedded dynamic SQL statements
1. How is a typical DB2 batch pgm executed? Use DSN utility to run a DB2 batch program from native TSO. An example is shown:
Use IKJEFT01 utility program to run the above DSN command in a JCL.
It is not mandatory to use DCLGEN. Using DCLGEN, helps detect wrongly spelt column names etc. during the pre-compile stage itself (because of the DECLARE TABLE ). DCLGEN being a tool, would generate accurate host variable definitions for the table reducing chances of error.
1. How does DB2 determine what lock-size to use? Based on the lock-size given while creating the table space Programmer can direct the DB2 what lock-size to use If lock-size ANY is specified, DB2 usually choses a lock-size of PAGE
1. What is the difference between CS and RR isolation levels? CS: Releases the lock on a page after use RR: Retains all locks acquired till end of transaction
1. Where do you specify them? ISOLATION LEVEL is a parameter for the bind process.
1. How do you simulate the EXPLAIN of an embedded SQL statement in SPUFI/QMF? Give an example with a host variable in WHERE clause. Use question mark in place of a host variable (or an unknown value). e.g.
1. What does it mean if the null indicator has -1, 0, -2? -1 : the field is null 0 : the field is not null -2 : the field value is truncated
1. How do you retrieve the data from a nullable column? Use null indicators. Syntax INTO :HOSTVAR:NULLIND
1. What else is there in the PLAN apart from the access path?
PLAN has the executable code for the SQL statements in the host program
1. What is lock escalation? Promoting a PAGE lock-size to table or table space lock-size when a transaction has aquired more locks than specified in NUMLKTS. Locks should be taken on objects in single table space for escalation to occur. 1. When is the access path determined for dynamic SQL? At run time, when the PREPARE statement is issued.
1. What is sqlcode -811? SELECT statement has resulted in retrieval of more than one row.
1. What are the advantages of using a PACKAGE? Avoid having to bind a large number of DBRM members into a plan Avoid cost of a large bind Avoid the entire transaction being unavailable during bind and automatic rebind of a plan Minmize fallback complexities if changes result in an error.
1. What is REORG? When is it used? REORG reorganizes data on physical storage to re-cluster rows, positioning oveflowed rows in their proper sequence, to reclaim space, to restore free space. It is used after huge updates, inserts and delete activity and after segments of a segmented table space have become fragmented. 1. How does DB2 store NULL physically? as an extra-byte prefix to the column value. physically, the nul prefix is Hex 00 if the value is present and Hex FF if it is not 1. What is CHECK PENDING? When a table is LOADed with ENFORCE NO option, then the table is left in CHECKPENDING status. It means that the LOAD utility did not perform constraint checking. 1. When do you specify the isolation level? How? During the BIND process. ISOLATION (CS/RR)
1. What is a DBRM, PLAN? DBRM: DataBase Request Module, has the SQL statements extracted from the host language program by the pre-compiler. PLAN: A result of the BIND process. It has the executable code for the SQL statements in the DBRM. 1. Is DECLARE TABLE in DCLGEN necessary? Why it used? It not necessary to have DECLARE TABLE statement in DCLGEN. This is used by the pre-compiler to validate the table-name, view-name, column name etc., during pre-compile. 1. What do you need to do before you do EXPLAIN? Make sure that the PLAN_TABLE is created under the AUTHID.
1. What is a collection?
a user defined name that is the anchor for packages. It has not physical existence. Main usage is to group packages.
1. How can you quickly find out the # of rows updated after an update statement? Check the value stored in SQLERRD(3).
1. What is EXPLAIN? EXPLAIN is used to display the access path as determined by the optimizer for a SQL statement. It can be used in SPUFI (for single SQL statement ) or in BIND step (for embedded SQL ). 1. Where is the output of EXPLAIN stored? In userid.PLAN_TABLE
1. Suppose I have a program which uses a dynamic SQL and it has been performing well till now. Off late, I find that the performance has deteriorated. What happened? Probably RUN STATS is not done and the program is using a wrong index due to incorrect stats. Probably RUNSTATS is done and optimizer has chosen a wrong access path based on the latest statistics. 1. What are the contents of a DCLGEN? GS EXEC SQL DECLARE TABLE statement which gives the layout of the table/view in terms of DB2 data types. A host language copy book that gives the host variable definitions for the column names.
1. Will pre-compile of an DB2-COBOL program bomb, if DB2 is down? No. Because the pre-compiler does not refer to the DB2 catalogue tables.
1. What are the isolation (also called isolation parameters) levels possible? CS: Cursor Stability RR: Repeatable Read
1. What is the picture clause of the null indicator variable? S9(4) COMP.
1. EXPLAIN has output with MATCHCOLS = 0. What does it mean? A non-matching index scan if ACCESSTYPE = I.
1. I use CS and update a page. Will the lock be released after Ive done with that page? No.
1. What are the various locking levels available? PAGE, TABLE, TABLESPACE
1. What is ALTER? SQL command used to change the definition of DB2 objects.
1. Can I use LOCK TABLE on a view? No. To lock a view, take lock on the underlying tables.
1. What are the disadvantages of PAGE level lock? High resource utilization if large updates are to be done
They contain executable code for SQL statements for one DBRM.
1. Lotof updates have been done on a table due to which indexes have gone haywire. What do you do? Looks like index page split has occured. DO a REORG of the indexes.
1. What is dynamic SQL? Dynamic SQL is a SQL statement created at program execution time.
1. What is IMAGECOPY ? It is full backup of a DB2 table which can be used in recovery.
1. What is QUIESCE? A QUIESCE flushes all DB2 buffers on to the disk. This gives a correct snapshot of the database and should be used before and after any IMAGECOPY to maintain consistency. 1. What does the sqlcode of -818 pertain to? GS This is generated when the consistency tokens in the DBRM and the load module are different.
1. What happens to the PLAN if index used by it is dropped? 1. 1. What is FREEPAGE and PCTFREE in TABLESPACE creation? PCTFREE: percentage of each page to be left free FREEPAGE: Number of pages to be loaded with data between each free page Plan is marked as invalid. The next time the plan is accessed, it is rebound.
1. Are views updatable? Not all of them. Some views are updatable e.g. single table view with all the fields or mandatory fields. Examples of non-updatable views are views which are joins, views that contain aggregate functions (such as MIN), and views that have GROUP BY clause. 1. What is COPY PENDING status? A state in which, an image copy on a table needs to be taken, in this state, the table is available only for queries. You cannot update this table. To remove the COPY PENDING status, you take an image copy or use REPAIR utility. 1. What is an inner join, and an outer join? Inner Join: combine information from two or more tables by comparing all values that meet the search criteria in the designated column or columns of one table with all the values in corresponding columns of the other table or tables. This kind of join which involve a match in both columns are called inner joins. Outer join is one in which you want both matching and non matching rows to be returned. DB2 has no specific operator for outer joins, it can be simulated by combining a join and a correlated sub query with aUNION. 1. 1. What is the difference between primary key & unique index?
Primary: a relational database constraint. Primary key consists of one or more columns that uniquely identify a row in the table. For a normalized relation, there is one designated primary key. Unique index: a physical object that stores only unique values. There can be one or more unique indexes on a table.
1. When do you use the IMAGECOPY? To take routine backup of tables. After a LOAD with LOG NO. After REORG with LOG ON.
1. What is RUNSTATS? A DB2 utility used to collect statistics about the data values in tables which can be used by the optimizer to decide the access path. It also collects statistics used for space management. These statistics are stored in DB2 catalog tables. 1. How do you insert a record with a nullable column? To insert a NULL, move -1 to the null indicator To insert a valid value, move 0 to the null indicator
Changman frame:-
CHANGEMAN
Change Man is a system that manages and automates the process of migrating software, or applications, from a development environment to a production environment. Change Man can manage the installation of a variety of components, such as: JCL, PROCs, AND UTILITY CONTROL CARDS Copy code used to compile the programs Batch programs written in Assembler, COBOL, COBOL II, or PL/I CICS programs written in Assembler, COBOL, COBOL II, or PL/I Programs written in Easytrieve, etc.,
Changes may now be Edited in either the Change Man staging or in the development libraries.
Once editing is completed, the components are ready to Staged. We use the STAGE function within Change Man to edit a component, compile and link edit a program. Components such as copy members are simply copied into the staging libraries, if they arent there already. The Change Package is now ready for Testing. The audit process ensures that no unexpected problems will occur. For example, if a component in the production library has been changed since it was checked out, Change Man alerts you to the problem by creating an out-ofsync condition for the package. After successfully passing the audit, the next step is to Freeze the Change Package. This locks the package(prohibiting further changes), and makes the package available for the promotion and approval processes. Promotion allows a Change Package to be moved through various levels of testing (e.g. promote from system testing to acceptance testing). Once all of the necessary Approvals have been done, the package is ready to be installed. The installation process depends upon the option used for installation, while creating package. Once the package has been installed, Change Man will perform the Baseline Ripple. Baseline Ripple is the process that Change Man executes to version all package components, i.e.: 0 becomes 1, -1 becomes 3, etc. and the new baseline 0 version is installed.
2 Freeze Freeze or unfreeze a package 3 Promote Promote or demote a package 4 Approve Approve or reject a package 5 List C CDF Display (to process) package list Concurrent Development Facility
N Notify Browse the Global Notification File O OFMlist Online Forms package list
Q Query
R Revert Revert a package to DEV status T Tutorial Display information about Change Man X Exit Exit Change Man
4 Utility Rename and Scratch information 5 Checkout Check out components from baseline or promotion 6 Stage 7 Audit Stage, edit, browse and delete components Audit a package
8 Recompile Recompile source code from baseline or promotion 9 Relink B Browse Relink or delete load modules Browse\print\copy baseline or promotion
C Compare Compare staging to baseline or promotion L Listing Browse compressed listings S Scan Scan baseline for character strings
Z Compress Compress change package Staging Libraries Press ENTER to process; Enter END command to exit.
When you create the Change Package, you are defining the outer structure of the change Package. You specify the date and time for installations, whether the package is temporary or permanent, the installation site, and implementation instructions, etc. Once you have completed the following four panels, the package is automatically assigned a unique Change Package ID.
Unplanned is for Emergency Loads ) PACKAGE TIME SPAN ===> (Permanent) (Optional package name) (* for list) (In days)
All the fields are required for the first time you create a Change Package. SO Enter the Relevant data and press Enter.
General Information:
This panel allows you to enter a description of the Change Package. It should be as complete and descriptive as possible.
Panel 2 of 4 - CREATE: PACKAGE DESCRIPTION Row 1 to 12 of 12 COMMAND ===> SCROLL ===> CSR
Press ENTER or END to continue or type CANCEL to exit. (minimum one line, maximum 46 lines)
________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________________ ____________________ ________________________________________________________________________ ******************************* Bottom of data ********************************
Implementation Instructions:
Use this panel to specify how the package is to be installed. This include the installation method,and specific implementation instructions to be used by in the individual overseeing the installation Panel 3 of 4 - CREATE: INSTALLATION INSTRUCTIONS Row 1 to 12 of 12 COMMAND ===> SCROLL ===> CSR
Press ENTER or END to continue or type CANCEL to exit. CONTINGENCY ===> 1 1-Hold production and contact analyst SCHEDULER ===> CMN (CMN)
(minimum one line, maximum 46 lines) ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________ ________________________________________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________________________ ____________ ________________________________________________________________________
sabbi vamsidar___________ 630-350-9483___ WARNING: From Install time of 0200 will automatically set the To Install time to 0230 . This is to enforce the 0200 load time for online modules.
After the information in the above panel is filled, press ENTER Change man will then automatically create your change package, return you to the first CREATE panel, and display the change package number in the upper right hand corner of the panel.
Checkout:
Use this panel to enter the checkout information, such as the package to which the component is to be checked out, the type of component, how the component is to be checked out(foreground of batch), and the name of the component that is to be checked out, etc., CHECKOUT OPTION ===> L List libraries where component is located PACKAGE ID ===> HFCG003413 (Package or Application name) (Name or Pattern for list; ABCDEF OR ABC*)
Pattern of only * Checks Out all Components related to Library Type. LIBRARY TYPE LANGUAGE ===> CP1 ===> (Blank for list) (Applies to source code; * for list) (Baseline 0 to -n; Promotion +1 to +n) (S-Staging library, P-Personal library)
PERSONAL LIBRARY ===> LIBRARY DSORG ===> PDS (Personal library: PDS, SEQ, PAN, LIB) (Y/N) (1-Online, 2-Batch)
Stage:
Once the components have been check out, they must be STAGED. you will use the STAGE function within Change Man to edit a component, compile and link edit a program, or to submit another transformation type of process like a JCL scan etc. Use the panels on the following page to complete the staging process for your Change Package components. Once these panels are completed, the component list will be displayed. From it you may browse ,edit,delete,recompile,display the source/load relationship, or stage a component for a list of valid selection codes.
2 Package Process package components 3 Parms Specify component list selection criteria
__ ETRTDATA CP1 ACTIVE __ LCC261 HI3 INCOMP __ LSADL05 HI3 ACTIVE __ LSAETAD HI3 ACTIVE __ LSAL05P HI3 ACTIVE __ LSAL05PC CP1 ACTIVE __ LSAL051 HI3 ACTIVE __ LSAUL05 HI3 ACTIVE __ LSEL05M HI3 ACTIVE __ LSPL05 HI3 ACTIVE __ LSPL05G CP1 ACTIVE __ LSRL05M HI3 ACTIVE
990403 045047
990405 062822 COBOL370 COBOL370 VEN080 990403 042020 COBOL370 COBOL370 VEN214 990403 042045 COBOL370 COBOL370 VEN214 990403 045624 COBOL370 COBOL370 VEN214 990403 045220 VEN214
990403 042233 COBOL370 COBOL370 VEN214 990403 042342 COBOL370 COBOL370 VEN214 990403 042422 COBOL370 COBOL370 VEN214 990403 042546 COBOL370 COBOL370 VEN214 990403 045057 VEN214
COMPILE PROCEDURE ===> COBOL370 (Blank for list; ? for designated procedure) COMPILE PARMS OR JOB NAME ===> (Enter JOB Name for PROCs requiring associated JOB for JCLCHECK) LINK EDIT PARMS ===> DB2 PRE-COMPILE ===> NO OTHER OPTIONS ===> YES (Y/N) (Y to display other options)
JOB STATEMENT INFORMATION: ===> //VEN080U JOB (050D,WD1A),CHNGMAN COMPARE,CLASS=W,____________________ ===> // MSGCLASS=T,NOTIFY=VEN080___________________________________________ ===> //*_____________________________________________________________________ ===> /*ROUTE PRINT PUNE______________________________________________________ Press ENTER to process; Enter END command to exit.
??? ENTRY TO DLITCBL ===> Y DROP INCLUDE STMTS ===> XPEDITER COMPILE ===> INCLUDE MQSERIES ===>
EASYTRIEVE NO NAME ===> FORMAT TO IMSTEST ===> (TEST MFS IS DEFAULT) JCK FULL LISTING USER OPTION 11 USER OPTION 13 USER OPTION 15 USER OPTION 17 ===> ===> ===> ===> ===>
USER OPTION 10 USER OPTION 12 USER OPTION 14 USER OPTION 16 USER OPTION 18
USER OPTION 19
===>
USER OPTION 20
===>
Use Y or N to select or deselect additional processing options; Press ENTER to continue; Enter END command to exit.
Package List:
Use the Package List panels as an alternative way to perform a variety of Change Man functions. Use this panel to select the Change Packages to be listed. If the Package Name field is left blank, you can select the application for which you would like to see a package list. Option is 5 from Primary change man screen PACKAGE LIST PARAMETERS COMMAND ===> SPECIFY SELECTION CRITERIA: PACKAGE ID PACKAGE STATUS ===> HFCG ===> (Full name or pattern; blank for list) (DEV, FRZ, APR, REJ, DIS, INS,
BAS, BAK, OPN, CLO, TCC orDEL) CREATORS TSO-ID WORK REQUEST ID DEPARTMENT PACKAGE LEVEL ===> ===> ===> ===> (1-Simple, 2-Complex,
3-Super, 4-Participating) PACKAGE TYPE PACKAGE TIME SPAN FROM INSTALL DATE TO INSTALL DATE ===> ===> ===> ===> ===> (Planned or Unplanned) (Permanent or Temporary) (YYMMDD) (YYMMDD) (YYMMDD) (YYMMDD) (Y/N)
===> ===>
PACKAGE ID STA INSTALL LVL TYPE WORK REQUEST DEPT PROMOTION AUD CREATOR
__ HFCG003193 DEV 990320 SMPL PLN/PRM VEN214 __ HFCG003411 DEV 990420 SMPL PLN/PRM VEN214 ******************************* Bottom of data ********************************
VEN214 VEN214
Utilities:
Recompile: The Recompile function can be used to resolve some of the out-of-sync conditions that can occur from the Audit process. The recompile is done from baseline or promotion, directly into staging libraries. - RECOMPILE SOURCE OPTION ===> R L Recompile one component List libraries where component is found
blank Display member selection list PACKAGE ID ===> HFCG003411 ===> (Blank or pattern for list) (Blank for list) (Blank for list) (Baseline 0, Promotion 1 to n)
COMPONENT NAME
Press ENTER to process; Enter END command to exit. After Entering the required data press Enter. You would get the Recompile job information screen where the data has to be entered and press ENTER. Your job is submitted. Relink: Any time a statically linked subroutine has been modified, relinking is required. Use think function to delete a relinked or recompiled load module from your Change Package. RELINK/DELETE LOAD MODULES OPTION ===> R D Relink single load module Delete relinked/recompiled module
blank Display LCT member selection list for multiple member processing PACKAGE ID RELINK FROM LCT MEMBER LIST ===> HFCG003411 ===> S ===> (S-Staging or B-Baseline) (Y Yes or N No; member list will be created with input library type) (Blank for list)
(Blank for list; required for options R/D) (Blank for list)
===> ===> ===> YES (Y/N) (Y/N for additional user options)
JOB STATEMENT INFORMATION: ===> //VEN080V JOB (050D,WD1A),CHNGMAN COMPARE,CLASS=W,____________________ ===> // MSGCLASS=T,NOTIFY=VEN080___________________________________________ ===> //*_____________________________________________________________________ ===> /*ROUTE PRINT PUNE______________________________________________________ Press ENTER to process; Enter END command to exit.
Fileaid :-
FILE AID
GENERAL INFORMATION Designed for applications and systems programmers, File-AID is an interactive, full-screen system for editing, browsing, defining, copying, reformatting, comparing, and printing VSAM, IAM, ISAM, PDS, BDAM, and sequential files under TSO/ISPF. KEY FEATURES File-AIDs functions enable you to significantly reduce the time r equired to perform day-to-day data file manipulation tasks such as creating and modifying test data, resolving production data problems, and performing ad-hoc file conversions and comparisons. KEY FEATURES: o Eliminates ISPF editing restrictions provides on-line editing of sequential, BDAM, PDS, ISAM, IAM, and VSAM files using
eliminates file size restriction by using selection criteria to limit the number of records to be edited supports files in compressed/encrypted format (with I/O exits) provides optional audit trail of all records updated, inserted, and deleted while editing a data file
o Uses existing COBOL or PL/I record layouts directly - the record layout is the sole definition of files thus eliminating the need to redefine the file/data in another language - superimposing the record layout over raw data brings meaning to that data - files may be printed in a formatted manner using the record layout o Has powerful, easy to use, copying and reformatting capabilities - these capabilities exist in both batch and on-line modes - no language to learn and no programming required
- records may be selected for copying using selection criteria based on record counts and/or individual fields . - selection criteria can be used in the Browse, Edit, Copy, Print, or Compare functions . o Runs as a single dialog under ISPF - uses menu-driven, full-screen, interactive ISPF-like displays - has user defined PF (program function) key support - can operate split-screen with ISPF/PDF - easy to learn and use - a fully interactive product with batch capabilities
specific values in
- executes in storage available above the 16 megabyte line on systems running MVS/XA or MVS/ESA GENERAL INFORMATION INVOKING File-AID File-AID executes as a dialog under IBMs ISPF dialog manager facility. You can invoke it by selecting the File -AID option from a customized version of the ISPF primary option menu, or from a sub-menu panel your installation has set up. If the File-AID execution CLISTS have been installed, you may invoke File-AID from any ISPF screen. For example, the command TSO FASTART suspends your current screen and displays the File-AID primary option menu. Upon exit from File-AID your suspended screen is restored. The following will be presented only if selected by number: 1 File-AID execution CLISTS GENERAL INFORMATION SUMMARY OF OPTIONS 0-C The File-AID primary options are: OPTION 0 SPECIFY ISPF AND File-AID PARAMETERS This option consists of the ISPF-provided parameter option screens and several screens to specify File-AID default parameters. OPTION 1 BROWSE FILE This option is used to display but not change the contents of files using any of three display modes formatted, vertical, and character. OPTION 2 EDIT FILE This option is used to create, display and change the contents of files using the formatted, vertical, and character display modes. OPTION 3 UTILITIES/E This option accesses a menu of dataset management utilities. Included are: 3.1 Library (PDS directory management and CSECT info), 3.2 Dataset (Non-VSAM dataset allocation, information), 3.3 Copy (Selective record copying for all file types including PDS members),
3.4 Catalog (search catalog using pattern characters) 3.5 VSAM (Define VSAM clusters, indexes, and paths online or in batch), 3.6 Search/Update (Scan or perform global changes for any dataset), 3.7 VTOC (Search volumes for datasets using pattern characters, analyze space), 3.8 Interactive (run File-AID/Batch online), 3.9 Submit (create batch JCL). OPTION 5 PRINT FILE This option is used to print data file contents, the selection criteria and rcd/layout XREFs created in options 6 and 7 of FileAID, formatted record layouts, and audit trail datasets created while editing a data file in option 2 (Edit) or 3.6 (Update) of File-AID. OPTION 6 EDIT SELECTION CRITERIA This option is used to create and maintain selection criteria for use in the Browse, Edit, Copy, Print, and Compare functions. OPTION 7 EDIT RCD/LAYOUT XREF This option is used to create and maintain rcd/layout XREFs for use in other File-AID functions. OPTION 8 VIEW RECORD LAYOUT This option is used to display the contents of COBOL or PL/I layouts as interpreted by File-AID. OPTION 9 REFORMAT FILE This option allows the records of an input file to be reformatted and written to an output file based on record layouts defining the input and output files. OPTION 10 COMPARE This option is used to compare two files and report the differences between them. OPTION C File-AID CHANGES This option documents changes made in the various releases of File-AID. GENERAL INFORMATION SCREEN FORMATS File-AID uses the full screen for display and entry of data. The first three lines of each display, called the heading lines, have a common format for all File-AID displays. The remainder of the screen may contain a list of options, input fields and prompts, or scrollable data. The first three lines of each display are formatted as follows: |-| | line 1: | TITLE | SHORT MESSAGE | | | SCROLL |
| ||line 2: | COMMAND/OPTION
|- |- | line 3: | LONG MESSAGE || The TITLE area (line 1) identifies the function being performed and, where appropriate, library or dataset information. The SHORT MESSAGE area (line 1) is used to indicate: - Current line or column positions - Successful completion of a processing function - Error conditions (accompanied by audible alarm) The COMMAND/OPTION area (line 2) is used to enter a command. On an option selection menu, it may be used to enter either a command or an option. The SCROLL area (line 2) contains the current scroll amount whenever scrolling is applicable. You may change it by overtyping. The LONG MESSAGE area (line 3) is used to display an explanation of error conditions upon request (see HELP command). This line will normally be blank or will contain heading (non data entry) information. Dataset specification screens allow you to enter information such as dataset names, member names, and other parameters. The fields in which you may enter information are labeled and preceded with an arrow. If you fail to enter a required value or if you enter inconsistent values, you are prompted with a message. |************************************************ The example at the right shows the edit dataset specification screen. | Edit Mode | | Specify Edit Information: | | | | | Edit Dataset name Member name Volume serial Disposition Create audit trail ===> FASAMP.* ===> ===> (Blank or (If datas | File-AID - Edit Dataset Specifi | COMMAND ===> | ===> C (F=Format |
Several fields on dataset specification screens are pre-entered with values that you entered the last time on that screen or on a similar screen. If the values are correct, simply press ENTER. If the values are not correct, overtype the fields that need to be changed before pressing ENTER. The pre-entered information comes from your user profile, which File-AID automatically builds and maintains across sessions. Information that is maintained in your user profile includes: - Dataset names and member names
- Job statement information - SYSOUT class for printed output - Parameters entered via Option 0 (Parameters) - PF-Key defaults
GENERAL INFORMATION MEMBER SELECTION SCREENS A member selection screen is an alphabetic list of the members of a partitioned dataset. It is displayed when requested from any of the File-AID functions 1-10. In most functions it is possible to obtain multiple member lists prior to entering the function. |************************************************ The example at the right shows the selection of member TESTFIL3 from the partitioned dataset PROJECT.TEST.DATA | S TESTFIL3 | TESTFIL4 | TESTFIL5 01.13 01.07 01.11 | File-AID - EDIT PROJECT.TEST.DATA | COMMAND ===> | NAME VER.MOD 01.04 01.02 CREATED LAST M
Scrollable data display screens show file contents or record layouts and allow up/down scrolling, and in some cases left/right scrolling. On many scrollable data display screens, you can also update file contents by typing over fields on the screen. The example below shows the edit formatted screen. You can scroll using the UP and DOWN commands, and can update file contents by typing over the FIELD VALUE column. File-AID - EDIT PROJECT.TEST.DATA(TESTFL3) LINE 00001 COMMAND ===> RCD SEQ NO 1 LEVEL NUMBER/DATA-NAME -OFFSET- FIELD VALUE01 ORDER-LINE 05 ITEM-NO 05 QTY-ORDERED 05 LIST-PRICE 1 11 14 PS/2 MOD50 100 2400.00 SCROLL ===> PAGE
Unscrollable data display screens show nonrepeating information which fits on a single screen. The Selection Criteria Options screen shown below is an example of this type of screen. ******************************************************************************** File-AID - Selection Criteria Options COMMAND ===> Selection criteria options First, start at the following record KEY Starting record key - OR Starting RBA Initial records to skip ===> OR at the following RBA ===> ===> 0 (both blank for start of file then skip this many records
GENERAL INFORMATION COMMAND ENTRY File-AID provides commands for commonly used functions. You may enter commands in one of two ways: 1) By typing the command in the command/option field (line 2 of the screen) and then pressing the ENTER key, or 2) By pressing a program function (PF) key to which you have assigned the desired command. You can assign commands to PF keys using option 0.0.3 or the KEYS command. When you press the PF key, the processing is the same as if you typed the command in the command field and pressed ENTER. Before you press a PF key, you can enter information in the command field. The PF key definition is concatenated ahead of the contents of the command field. For example, suppose you assign the DOWN command to the PF8 key. If you type 6 in the command field and press PF8, the results are the same as if you had typed DOWN 6 in the c ommand field and pressed ENTER. You can stack multiple commands for execution in one interaction by entering a special delimiter between the commands. The default delimiter is a semicolon (;). You can change the delimiter using option 0.0.1. For example: COMMAND ===> DOWN 10;LEFT In this example the DOWN and LEFT commands have been stacked. GENERAL INFORMATION COMMAND SUMMARY File-AID primary commands are divided into four categories listed below. Commands designated with an asterisk (*) have the same syntax and function as in ISPF. In many File-AID functions, the information to be displayed exceeds the screen size. Scroll commands allow you to move the screen window in as many as three dimensions across the information: up/down, left/right, and forwa rd/back. For a more detailed description of scrolling, see the SCROLLING section within GENERAL INFORMATION. The scroll commands are: UP * Causes scrolling toward the top of a record, file, record layout, or member list.
DOWN * Causes scrolling toward the end of a record, file, record layout, or member list.
LEFT * Causes scrolling toward the left margin of the data or causes backward scrolling towards the beginning of a file. RIGHT * Causes scrolling toward the right margin of the data or causes forward scrolling towards the end of a file. FORWARD BACK LOCATE Causes record scrolling toward the bottom of the file. Causes scrolling toward the top of the file. Causes up or down scrolling to the specified line number, label, or member name.
LOCATE Causes up or down scrolling to the record with a label (dataname) or exclude classification. Also causes scrolling to a data-name that contains, in part or full, the data name(occ) string. LR Causes forward or backward scrolling to a specified record number, label, or any record with a label classification.
RECORD MANIPULATION COMMANDS Record manipulation commands allow you to update file contents and to find and change occurrences of a string in a file. The record manipulation commands are: INSERT DELETE REPEAT FIND Causes n records to be inserted after the current record (not supported for BDAM files) Causes n records to be deleted beginning with current record (not supported for BDAM files) Causes a record to be repeated n times (not supported for BDAM files) Causes one or all occurrences of a string to be found
RFIND * In Edit or Browse, causes the previous FIND command to be repeated CHANGE Causes one or all occurrences of a string to be changed
RCHANGE * In Edit, causes the previous CHANGE command to be repeated SAVE UNDO * Causes the data to be stored back into the edit dataset Causes the last applied change to data to be reversed
When using an XREF to work with segmented records the following are valid: ADD NEXT REMOVE TOP USE Insert a segment at a point in the record. Display NEXT segment of record using correct layout Remove a segment at a point in the record.
Return to start of record and display base Display layouts and allow manual selection and relocation
SESSION CONTROL COMMANDS Session control commands have to do with terminating the current function or switching from one function to another. The session control commands are: CANCEL * Causes editing to be terminated without saving the data
END * Terminates the current operation and returns to the next higher level screen (also used to indicate end of table input) RETURN * Causes an immediate return to the primary option menu or to a specified option Recursive commands: File-AID has special commands like F1 (Browse), F2 (Edit), F33 (Copy) that let you suspend your current display and start another function. Upon end from the new function, the suspended display is resumed. The following will be presented only if selected by number: 1 Recursive Commands
MISCELLANEOUS COMMANDS Miscellaneous commands cover a variety of functions. They are listed and briefly described below. KEY Causes a specified key to be retrieved or the key specification screen to be displayed (applies to BDAM, ISAM, VSAM-KSDS, VSAM-RRDS, and IAM files only) HEX * Causes data to be displayed in either hexadecimal or character format
CAPS * Causes alphabetic data entered from the terminal to be either translated to upper case or left as-is RESET * Causes a general resetting of intensified messages and incomplete line commands CHAR FORMAT VFMT Causes a switch from Formatted or Vertical editing modes to Character editing mode Causes a switch from Vertical or Character editing modes to Formatted editing mode (Aliases: FMT, MAP) Causes a switch from Formatted or Character editing modes to Vertical editing mode
SPLIT * Causes split screen mode to be entered or changes the location of the split line SWAP TSO KEYS * Moves the cursor to wherever it was previously positioned on the other logical screen of a split screen pair * Allows a TSO command or CLIST to be entered from any screen * Causes an immediate display of a screen on which current PF key definitions are displayed and modifiable
PANELID * Causes all subsequent screens to be displayed/not displayed with the panel identifier shown in the upper left corner of the screen HELP * Displays additional information about an error or switches to the on-line tutorial
CURSOR * Moves the cursor to the first input field on line 2 PRINT * Causes a snapshot of the current screen to be recorded in the ISPF list file for subsequent printing PRINT-HI* Same as PRINT except that high-intensity characters on the screen are printed with overstrikes to simulate the high-intensity display JCL Causes the generated JCL to be displayed
GENERAL INFORMATION PA KEYS The two program access (PA) keys have special meaning in ISPF and File-AID. They are not equated to ISPF or File-AID commands, and they may not be reassigned. Normally, you should not use PA1 while operating in File-AID full screen mode. However, there are two exceptions.
If you press PA1 after the keyboard has been unlocked by File-AID, it is treated like PA2 (RESHOW). It does not cause exit from File-AID. However, if you press PA1 a second time without any intervening interaction, it causes the current processing to be terminated and the ISPF PRIMARY OPTION MENU is redisplayed. If you press PA1 after the keyboard has been manually unlocked (by pressing the RESET key), it usually causes the current processing to be terminated. The ISPF PRIMARY OPTION MENU is redisplayed. You can use PA2 to reshow the last full screen image displayed by File-AID. You may need to reshow the screen if you accidentally press the ERASE INPUT or CLEAR key, or if you have typed data on the screen that you want ignored and have not yet pressed ENTER or a PF key. DEFAULT ASSIGNMENT PROGRAM FUNCTION KEYS When you begin using File-AID, commonly used commands are assigned to the PF keys as shown on the right. | | | | ||-|| | PF4/16 | PF5/17 | PF6/18 | |-|- | | | PF1/13 | PF2/14 | PF3/15 | HELP | SPLIT | END | |
You can change these default assignments in option 0.0.3 or via the KEYS command. | RETURN | RFIND | RCHANGE | | | | |
| RIGHT | RETRIEVE | | | |
|-||| GENERAL INFORMATION SCROLLING In many File-AID functions, the information to be displayed exceeds the screen size. Scrolling allows you to move the screen window in as many as three dimensions across the information: up/down, left/right, and forward/back. You accomplish this using two basic types of scrolling: PAGE SCROLLING The page scrolling commands and default PF key assignments are:
UP
DOWN (PF8/20) to scroll toward the bottom of the data LEFT (PF10/22) to scroll toward the first column of the data RIGHT (PF11/23) to scroll toward the last column of the data These commands function exactly as they do in ISPF/PDF. On all screens involving scrolling, a scroll amount is displayed on line 2 of the screen. This value indicates the number of lines or columns to scroll when you enter one of the four page scrolling commands. You can change the scroll amount by simply typing over the scroll amount field. Valid scroll amounts are: - a number from 1 to 9999 specifies the number of lines/columns to scroll - PAGE specifies scrolling by one logical page - DATA specifies scrolling by one logical page less one line - HALF specifies scrolling by one-half logical page - MAX specifies scrolling to the top, bottom, left margin, or right margin, depending on which scrolling command is used. - CSR specifies scrolling based on the current position of the cursor. The line or column where the cursor is positioned is moved to the top, bottom, left, or right of the screen depending on which scrolling command is used. If the cursor is not in the body of the data, or if it is already positioned at the top, bottom, left, or right, a full page scroll occurs. For scrolling purposes a page is defined as the amount of information currently visible on the logical screen. In split screen mode, for example, the edit character display might have 12 lines by 80 columns of scrollable data. In this case, a scroll amount of HALF would move the window up or down by 6 lines, or right or left by 40 columns. The current scroll amount is saved in the user profile. When you type over the scroll amount, the new value remains in effect until you change it again. You can override the current scroll amount on a given interaction by entering a scroll amount in the command field and using a scroll command or PF key. For example, you can enter: COMMAND ===> DOWN 5 COMMAND ===> 5 and press ENTER or and press the DOWN PF key
Either form results in a temporary, one-time override of the scroll amount. To reduce keystrokes, you can change the scroll amount field by typing over the first character(s) only: - To change the scroll amount to PAGE, DATA, HALF, MAX, or CSR, type over the first character with P, D, H, M, or C respectively. - To change the scroll amount to a number of lines or columns, type over the first character(s) with the desired number. RECORD SCROLLING The record scrolling commands are not directly assigned to a PF key: FORWARD (or FWD ) to scroll toward the end of the file BACK to scroll toward the beginning of the file
The LEFT (PF10/PF22) and RIGHT (PF11/PF23) commands can be used in place of BACK and FORWARD, respectively. These commands apply to the screens where one record per screen is displayed formatted with a record layout (edit/browse Formatted, edit formatted field selection criteria, define formatted XREF) and are used to move forward or backward n records (or criteria sets) in a file. You enter the scroll amount for record scrolling in the COMMAND input area (unless you have assigned both the command and the scroll amount to a PF key). Valid scroll amounts are: - a number from 1 to 2,147,483,647 specifies the number of records to scroll FORWARD or BACK - MAX or M specifies scrolling to the last record (FORWARD) or the first record (BACK) in the file GENERAL INFORMATION SPLIT SCREEN There may be times when you want to perform another File-AID function or ISPF/PDF function without ending the current function. File-AID provides the ability to split the physical screen image into two logical screens that operate independently of one another, as though you had two terminals. In split screen mode, only one of the logical screens is considered active at a time. Any interactions, such as pressing ENTER or a PF key, are interpreted as having meaning for the active screen. The current location of the cursor identifies which of the two screens is active. To switch from one screen to the other, simply move the cursor to the desired screen or enter the SWAP command. GENERAL INFORMATION TERMINATING File-AID You can terminate File-AID in any of three ways: 1) by entering the END command on the primary option menu 2) by entering option X on the primary option menu 3) by entering the =X jump command from any screen When you invoke File-AID from the ISPF primary option menu, eventually terminate ISPF/PDF using the END command, and used either the log or list files, a termination screen is displayed. GENERAL INFORMATION File-AID DATASETS General information about the use of datasets by File-AID follows. Each topic is presented in sequence, or may be selected by number: 1 Conventions for Specifying Datasets 2 Data File Dataset 3 Record Layout Dataset and source language support 4 Layout XREF Dataset 5 Selection Criteria Dataset 6 Reformat Definition Dataset 7 Member List Processing All datasets processed on-line must reside on a direct access storage device or on a mass storage device. Uncataloged disk data file datasets are allowed in all functions and can be accessed by specifying a VOLSER.
Temporary data files and tape datasets are allowed as input to independent File-AID/Batch jobs for which you develop the JCL. File-AID/Batch JCL can be optionally generated with Copy (3.3), Search/Update (3.6), Print (5.x), Reformat (9), and Compare (10)
CONVENTIONS FOR SPECIFYING DATASETS When a Dataset Name is required in File-AID, you may enter a fully qualified (quoted), unqualified (no quotes, userid prefix implied), or pattern (catalog search request). File-AID saves the name of the most recently referenced dataset of each type (Data file, Record Layout, XREF, Selection Criteria) in your session profile and redisplays these names on all appropriate screens. FULLY QUALIFIED NAMES You may enter any fully qualified data set name by enclosing the name in apostrophes (). Trailing quotes are never required. Example: Dataset name ===> SYS1.MACLIB UNQUALIFIED NAMES If you omit the apostrophe(s), your TSO prefix is left-appended to the entered data set name (unless the TSO profile option NOPREFIX has been specified). If you specify a default VSAM INTERMEDIATE NAME with the 0.1 System Parameters function, and/or your installation uses the optional File-AID VSAM high level index, and no dataset can be Found with the combination of TSO-PREFIX.DATASET, a new VSAM prefix is constructed as follows: VSAM high level index.VSAM INTERMEDIATE NAME. The constructed VSAM prefix is then left-appended to the entered dataset name (VSAM prefix.dataset) and the catalog is again searched for the dataset. If allocating a VSAM cluster, with the 3.5 VSAM utility, the VSAM prefix is always constructed when an unqualified name is specified. UNCATALOGED DATASETS If the dataset is not cataloged, you must specify a Volume serial number. USING PATTERN CHARACTERS CATALOG SEARCH You can use pattern characters in the dataset field to dynamically invoke File-AIDs catalog search (3.4) to look for matching dataset names. Valid pattern characters are: ? and % (single character) * (multiple characters in one node), + (0 or more nodes). Pattern characters are used to represent any or all characters which are not part of the high-level node of a dataset name. The high-level node must be fully specified. Following are some examples of using the asterisk (*) to retrieve a list of datasets: COMPARE DATASET ===> FILE.* or COMPARE DATASET ===> userid.FILE.* or COMPARE DATASET ===> FILE.ABC*
USING PATTERN CHARACTERS CATALOG SEARCH (cont.) After specifying the pattern, press ENTER. The File-AID 3.4 Catalog Utility is invoked, and a list of datasets corresponding to the pattern that you specified is displayed. Type S in the COMMAND column to the left of the name of the dataset you want to select and press ENTER. The selected dataset will be used and will replace the pattern you specified on the panel for the function you are performing. If you are not licensed for File-AID/SPF, you will receive an error if you use a pattern character in the dataset field. For further information on pattern characters, explore the tutorial for the 3.4 Catalog utility or see the File-AID Online Reference Manual, CATALOG UTILITY. PDS DATASET(MEMBER) A member name enclosed in parentheses may follow the data set name (within the apostrophes, if they are present) for partitioned data sets. For selection purposes, specifying a member name for a partitioned dataset will cause the member to be processed as a sequential dataset. In most instances a Member Name prompt is provided under the Dataset Name prompt. If a member name is specified in parentheses along with the dataset name, the member information is considered as if it had been entered in the Member Name field. PDS MEMBER NAME MASKS When referencing a PDS dataset, you may specify a Member Name of blank, or use a pattern to generate a list of members for selection. PDS MEMBER NAME MASKS (cont.) You can use a question mark (?) or percent (%) to represent a single character of the member name or an asterisk (*) to represent multiple characters in a member name. However, you must enter at least the first character of the member name before you can use the asterisk. (Exception: in 3.3 Copy or 3.6 Search Update, a member name of asterisk (*) means to process all members and to bypass all PDS Processing Options screens and member lists.) Using blank or a member name pattern will either cause a File-AID member list to be displayed or a PDS Processing Option screen to appear to provide additional member selection options. Once a list of members is presented, you can select a member from this list by using the S line command. You can also enter the full member name, in parentheses, on the same line as the dataset name. If you do so, you can ignore the Member Name field. GENERATION DATASETS Generation data sets may be referenced by using a signed or unsigned number enclosed in parens. Example: ===> GDS.TEST(0) This example references the most recently allocated data set in the generation data group. Minus numbers reference previously allocated data sets and positive numbers reference unallocated data sets of the group.
CATALOG DATASET On some panels a catalog dataset name may be entered. In this case whether the catalog dataset name is enclosed in quotes or not, the name is always considered to be a fully qualified name and no prefix is appended to it. Catalog dataset name ===> CATALOG.DATASET Catalog dataset name ===> CATALOG.DATASET In the above example, both entries are correct and treated equally. DATA FILE DATASET The data file dataset contains the data to be browsed, edited, reformatted from/into, copied from/into, searched, updated, printed or compared. It can also be a dataset you are defining or managing with the extended utilities. File-AID supports user written I/O exit programs for data file datasets. I/O exits can handle compression/decompression, encryption/decryption, or can perform all physical I/O to your data file. See the File-AID Installation Guide for details and samples. The next two tutorial pages display tables showing the combinations of dataset organizations and record formats allowed for data files. For sequential (PS), partitioned (PO), BDAM (DA), and ISAM (IS) files, the LRECL and BLKSIZE can range from 1 to 32,760 for each RECFM. For VSAM files, the LRECL can range from 1 to 32,767. The table below shows the combinations of dataset organizations and record formats allowed for data files.
RECFM
F X X
FB X X
V X X
VB X X
U X X
SPANNED X X
n/a
n/a
The table below shows the combinations of dataset organizations and record formats allowed for VSAM data files.
RECFM
FB
VB
SPANNED
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
AM (VSAMLDS)
1) VSAM-KSDS and ESDS files are treated as variable length files. Also, the concept of blocking, as applied to PS,PO, and IS files, does not apply to VSAM. 2) File-AID does not support ISAM files with OPTCD=L in the DCB information when the key starts in the first position (RKP=0 for fixed length files, RKP=4 for variable length files) 3) File-AID does not support fixed length unblocked ISAM files with a relative key position of 0 (RKP=0), or variable length unblocked ISAM files with a relative key position of 4 (RKP=4). 4) File-AID supports reading a VSAM-KSDS in an alternate key sequence via a VSAM PATH. A PATH name may be specified for the input data file name in the browse, edit, copy, print, and compare options. 5) File-AID treats RECFM=FB BDAM files as RECFM=F (i.e., records are not de-blocked.) Keyed BDAM files are processed by File-AID as if the key were concatenated in front of each data block. 6) IAM files exist as fixed or variable length files. Due to a constraint in the information available to File-AID from the IAM access method, all files are currently handled as variable length files. If the length is changed on an IAM file which is truly fixed, File-AID will display an error message. IAM files are processed as VSAM-KSDS files in all functions. OS PASSWORD PROTECTED FILES File-AID allows you to access data file datasets with OS password protection. Any dataset may be protected to permit readonly or read/write access. More than one password may be assigned to the same dataset. A dataset that is read/write protected, for example, might allow several authorized users to read it, but only one user to write. If you attempt to access a dataset protected by an OS password, File-AID will present the OS-Password-Protected screen containing a field where you can specify a dataset password as follows: Dataset password ===> A nondisplay input field is used so that the password does not appear on the screen while you are typing it. Note that the File-AID 3.5 VSAM utility supports specification and modification of passwords for VSAM clusters. RECORD LAYOUT DATASET This dataset contains the record layouts which are used in many File-AID functions. The record layout dataset can be one of four types:
TYPE
DSORG PO * * PS
LRECL 80 * * 80
Must conform to the requirements for a valid CA-PANVALET/LIBRARIAN file. CA-PANVALET and CA-LIBRARIAN are products of Computer Associates International, Inc.
A record layout may be a separate COPYLIB member or may be hard-coded within the source statements of a program. If the layout is in a program or if a COPYLIB member contains multiple record layouts, you can isolate the specific layout, or portion of a layout, that File-AID should use by specifying a starting data-name. If you do not specify a starting data-name, File-AID uses every layout found in the program, or COPYLIB member, to format the data, treating the second through last layouts as additional layouts that may be manually selected and overlaid at any offset via the USE command. Note: File-AID Release 6 MAP libraries containing compiled record layouts are accepta ble as a record layout library. LANGUAGE SUPPORT File-AID supports source record layouts coded in COBOL or PL/I. Layouts may be used when browsing, editing, printing, reformatting and comparing data files. Layouts can also be used to define selection criteria and to specify tests for multiple record type layout usage. File-AID automatically recognizes the source language whenever a layout is referenced. File-AID supports Format 1 of the COBOL data definition statement and ignores Formats 2 and 3. When a 66 or 88 level item is encountered File-AID skips to the end of the sentence and performs no syntax checking. FORMAT 1 level number data-name REDEFINES clause BLANK WHEN ZERO JUSTIFIED clause OCCURS clause PICTURE clause SIGN clause SYNCHRONIZED clause USAGE clause VALUE clause. The following rules apply to Format 1: 1) The first data description entry in the COBOL layout need not have level number 01. 2) If multiple data description entries have level number 01, the second through n 01 level entries are treated as though they redefine the first 01 level entry. Each 01 level entry need not be successively longer than the previous 01 level entry. 3) The clauses may be written in any order. 4) The PICTURE clause must be specified for every elementary item with the exception of INDEX, COMP-1, and COMP-2 data items. 5) Each data description entry must be terminated by a period. 88 condition-name VALUE clause. FORMAT 3 FORMAT 2 66 data-name-1 RENAMES clause.
7) The EJECT, SKIP1, SKIP2, and SKIP3 reserved words may be imbedded between data definition statements within a COBOL layout. File-AID skips over these words. 8) File-AID also skips over the TITLE statement, which is valid in VS COBOL II. 9) Sort file description entry statements (SD) and file description entry statements (FD) may be imbedded within the COBOL layout. File-AID skips these statements and performs no syntax checking. 10) File-AID also skips debugging lines (D in column 7) and sentences which do not begin with a valid level number. 11) File-AID ignores the REDEFINES clause if it is on the first data description entry in the COBOL layout.
The level number and data-name are required in the COBOL data description entry. The format is: Level number data-name The level number may be any number from 1 through 49. You may not use level number 77. Data-names must be 30 characters or less but are not otherwise validated. For example, you are not restricted to using characters A through Z, 0 through 9, and hyphen to form data-names, and you need not make data-names unique. The keyword FILLER is treated the same as other data-names. The format of the REDEFINES clause is: level number data-name-1 REDEFINES data-name-2 The level numbers of data-name-1 and data-name-2 must be identical and can be any level number from 1 to 49. Between the data descriptions of data-name-2 and data-name-1, there may be no entries having numerically lower level numbers than the level number of data-name-2 and data-name-1. The data description entry for data-name-2 may not contain an OCCURS clause. However, data-name-2 may be subordinate to an item containing an OCCURS clause with or without the DEPENDING ON option. Items subordinate to data-name-2 may contain an OCCURS clause without the DEPENDING ON option. Data-name-1 and any items subordinate to data-name-1 may contain an OCCURS clause with or without the DEPENDING ON option. If data-name-1 contains an OCCURS clause, its length is computed to be the length of one occurrence multiplied by the number of occurrences. The size of the redefining area must be less than or equal to the size of the redefined area. Multiple redefinitions of the same redefined area may reference the data-name of the redefined area or the data-name of any of the preceding redefining areas. REDEFINES clauses may also be specified for items subordinate to items containing REDEFINES clauses. File-AID ignores the REDEFINES clause if it is on the first data description entry in the COBOL layout. The format of the BLANK WHEN ZERO clause is: BLANK (WHEN) ZERO The word WHEN is optional. This clause is checked for valid syntax but it does not affect processing in any way. The format of the JUSTIFIED clause is: JUSTIFIED (RIGHT) JUST The JUSTIFIED clause is used to override normal positioning of data within a receiving alphanumeric data item. This clause affects processing in the reformatting function (option 9) only.
Normally data is left justified in the receiving field and either truncation or blank padding occurs on the right. When the JUSTIFIED clause is specified, data is right justified in the receiving field and either truncation or blank padding occurs on the left. The OCCURS clause has two basic formats:
FORMAT 1
OCCURS integer-2 TIMES (DEPENDING ON data-name-1) (ASCENDING KEY IS data-name-2 (data-name-3)) DESCENDING (INDEXED BY index-name-1 (index-name-2))
FORMAT 2
OCCURS integer-1 TO integer-2 TIMES (DEPENDING ON data-name-1) (ASCENDING KEY IS data-name-2 (data-name-3)) DESCENDING (INDEXED BY index-name-1 (index-name-2)) The words TIMES, KEY IS, and BY are optional in both formats. In FORMAT 1, integer-2 represents the exact number of occurrences if the DEPENDING ON option is not present, or the maximum number of occurrences if the DEPENDING ON option is present. Integer-2 must be greater than 0 and less than 32,768. In FORMAT 2, integer-1 represents the minimum number of occurrences and integer-2 represents the maximum number of occurrences. Integer-1 must be greater than or equal to 0, and integer-2 must be greater than integer-1 and less than 32,768. Three nested levels of OCCURS clauses are allowed. The OCCURS clause may not be specified on 01 level items. The ASCENDING KEY, DESCENDING KEY, and INDEXED BY options are checked for valid syntax, but do not affect processing in any way. Data-name-1, the object of the DEPENDING ON option: - must be defined as an integer - must not contain or be subordinate to an OCCURS clause There can be multiple OCCURS DEPENDING ON clauses per COBOL layout. The format of the PICTURE clause is: PICTURE (IS) character-string PIC File-AID interprets all options of the PICTURE clause. The alphabetic, alphanumeric, alphanumeric edited, and numeric edited categories of data are all treated as alphanumeric data (i.e. treated as if the character string contained all Xs). Picture characters A X B 0 Z , . * - CR DB $ E
are all treated as the picture character X (XX for CR and DB). For alphanumeric edited and numeric edited data items, FileAID does not validate the character string according to the precedence of symbols as COBOL does. External floating point items are fully syntax checked and treated as picture X items. Also, the scaling position character, P, is supported The format of the SIGN clause is: SIGN (IS) LEADING (SEPARATE CHARACTER) TRAILING The word CHARACTER is optional in the SEPARATE option. File-AID treats the SIGN clause exactly as COBOL treats it. The format of the SYNCHRONIZED clause is: SYNCHRONIZED (LEFT) SYNC (RIGHT)
The SYNCHRONIZED clause may be specified at the 01 or elementary item level. When specified at the 01 level, every elementary item within the 01 level is synchronized. File-AID treats all other aspects of the SYNCHRONIZED clause exactly as COBOL treats them, including computation of slack bytes for groups, defined with the OCCURS clause, containing synchronized items. The format of the USAGE clause is: DISPLAY DISPLAY-1 COMPUTATIONAL COMP COMPUTATIONAL-1 USAGE (IS) COMP-1
COMPUTATIONAL-2 COMP-2 COMPUTATIONAL-3 COMP-3 COMPUTATIONAL-4 COMP-4 INDEX POINTER (VS COBOL II only) PACKED-DECIMAL (VS COBOL II only) BINARY (VS COBOL II only)
The USAGE clause can be specified at any level of data description. However, if the USAGE clause is written at a group level, it applies to each elementary item in the group. The usage of an elementary item may not contradict the usage of a group to which an elementary item belongs. If the USAGE clause is not specified for an elementary item, or for any group to which the item belongs, usage DISPLAY is assumed. COMPUTATIONAL-4 and COMP-4 items are treated as COMPUTATIONAL items. The format of the VALUE clause is: VALUE (IS) literal The VALUE clause is checked for valid syntax but does not affect processing in any way. COBOL LAYOUT ERRORS When File-AID encounters an error during its on-line processing of a COBOL layout, an error messages is written to your ISPF log file. These messages contain an image of the last line File-AID read from the COBOL layout, plus the internal layout representation File-AID built before the error occurred. By using these messages in conjunction with the error message File-AID displays at your terminal, you will be able to resolve most COBOL layout errors. LAYOUT MEMBER SELECTION Whenever you leave the layout member name blank or use a pattern, File-AID presents a member list. A partitioned processing options (PPO) screen usually appears first to let you filter the member list to improve performance. A pattern consisting only of an asterisk (*) tells File-AID to list all members and to bypass the PPO screen. NOTE: Using a single asterisk (*) pattern to list all members of a large layout library (such as a Panvalet or Librarian library) may be time consuming. Member list presentation occurs automatically in the XREF function when you use line commands, or enter a pattern in the member name field (with or without using the S or SU line command). SOURCE STATEMENT SELECTION SOURCE OPTIONS When File-AID cannot compile your record layout with the default source options, the Source Statement Selection panel is displayed. This panel contains a Source Statement selection area and a compiler option section. Record layout extraction can be done by Character string or Statement number.
Character string selection is performed by entering the full or partial dataname of the first group item wanted. The ending string is only needed for PL/I or when a
Please enter the beginning and term Source statement line numbers or bl
Ending string
===>
Selection by number is performed by entering the beginning and ending statement numbers. The numbers can be standard (cols 73-80), relative, or COBOL (cols 1-6). Relative is
Record layout selection bySourceState Beginning number Ending number Number type ===> ===> ===>
The Source Options panel is also used to enter compiler options. The compiler options are Language, Starting level number, Literal delineator (COBOL only) and Use 48 character set (PL/I only).
Language is specified by entering COBOL or PL/I in the language field. Starting level number indicates the level number to be used to indicate the start of a new copybook to be compiled. Literal delineator indicates to the
Starting level numb ===> 01 Literal delineator ===> QUOTE Use 48 character set ===> YES -
COBOL compiler that either the quote () or the apostrophe () is the character used to delineate literals. -Use 48 character set indicates to the PL/I compiler that the source is written in the 48-character set. If File-AID cannot determine the language, or if compilation fails, it will display this panel to allow you to change source or compile options. XREF DATASET This dataset contains XREF members created using option 7 of File-AID. XREF members contain information relating record data to a record layout. The XREF dataset must have the following attributes:
DSORG PO
RECFM VB
LRECL 300
You create XREF members to communicate information about the record layout dataset to File-AID in the following situations: 1) the data file you want to work with contains records with differing formats, requiring different record layouts to define the various formats 2) the record layout that defines the data file is hard-coded in a program 3) the record layout that defines the data file is stored in a COPYLIB member that contains multiple record layouts 4) each record in the data file requires two or more record layouts, presented in sequence, to define it For the first situation, the XREF contains two pieces of information: 1) the name or the length and starting position of the field(s) within each data record that File-AID should use to identify the data records type (referred to as the record type field(s)) 2) a list of all the possible record type values and the corresponding layout library member which defines the data records with those values For the second and third situations, the XREF contains the data-name that starts the data structure you want (referred to as the starting data-name). File-AID reads the layout from the source library member (containing either multiple layouts or a program) starting with the data-name you specify. File-AID stops reading when it finds a new data structure (equal or lower level number) or when the end of the record layout, library member, or program is reached. For the fourth situation, the XREF contains the names of the layout library members for each segment of a data record. It also contains the rules for identifying each segment of the record by locating the segment type field and field values to use for selecting a segment layout (via NEXT command of Formatted Browse/Edit). In any of the File-AID primary options which use layouts to define the data, the record layout dataset and XREF dataset information are specified as shown in the example below. Specify Record layout and XREF Information:
Record layout usage Record layout dataset Member name XREF dataset name Member name
PROD.COPYLIB (Blank or pattern for member list) FASAMP.XREF ORDRFILE (Blank or pattern for member list)
RECORD LAYOUT USAGE indicates whether you will use a single record layout (usage S), a layout XREF (usage X), or no source layouts (usage N) to define the file. The table below shows the valid dataset and member entries for the record layout and layout XREF datasets, for each layout usage.
LAYOUT USAGE
XREF DATASET
sequential file, or member of partitioned/PAN/LIB file sequential file, or partitioned/PAN/LIB file; (required) member must be blank ignored
ignored
N
SELECTION CRITERIA DATASET
ignored
This dataset contains existing selection criteria information created using option 6 of File-AID. You can use saved selection criteria in the browse, edit, copy, search/update, print, and compare functions. The selection criteria dataset must have the following attributes:
DSORG PO
RECFM V, VB
LRECL 300
This dataset contains saved Reformat Definitions created using option 9 of File-AID. You can use a saved Reformat Definition online or in batch (REFORMAT function). The Reformat Definition dataset must have the following attributes:
DSORG PO
RECFM V, VB
LRECL 1570
When partitioned datasets are specified on the dataset specification screens, you may display a member list by: - Leaving the member name field blank File-AID displays a list of the members in the partitioned dataset - Entering a pattern as the member name A pattern is a partial member name containing one or more of the single character wild cards * (asterisk) ? (question) or % (pct). If any pattern character is present, the name becomes a mask matching any member name starting with the pattern entered (as if the pattern contained all wild cards at the end). Therefore, one trailing pattern character is used only if it is the only wild card in the mask, otherwise it is assumed. (Ex. PR?G is the same as PR?G???? and PR?G*. However PRO and PRO* are different because PRO is a member name not a pattern like PRO* is.) For example, the patterns: ?RO*, ?RO, P*, PR?G%, P?O?G, PROGRAM* all match and produce the following list: PROGRAM1 PROGRAM2
PROGRAM3 Use the S (Select) line command to select the member you want. You may also scroll through the member list using the UP and DOWN commands. In addition, you can enter a LOCATE primary command and scroll directly to (or near) a specified member name. MULTIPLE PDS DATASET MEMBER LIST CONVENTIONS: On certain dataset specification screens, you can specify multiple partitioned datasets. Therefore, it is possible for you to receive multiple member list screens (one for each partitioned dataset specified without a member or with a pattern) before proceeding to the next screen in the function. The member lists are displayed in the sequence that the datasets appear on the dataset specification screen. PDS PROCESSING OPTIONS FOR PROCESSING PARTITIONED DATASETS: If the main dataset in Browse (1), Edit (2), Copy (3.3), Search/Update (3.6), and Print data (5.1), is a PDS and an explicit member is not specified, File-AID provides a PDS Processing Options (PPO) screen. The PPO screen lets you specify additional member qualification filters such as: member name range, last modified userid range, create date range, and modified date range. If you wish to bypass the PPO screen and process all members, use a member name of * on the main entry screen (Ex. Edit DSN=MY.PDS(*) ). Note that when multiple PDSs are specified on the entry screen the list of members matching your PPO options may not appear until AFTER all other PDS member lists have been presented and a member selected. ABNORMAL TERMINATION File-AID can abnormally terminate in one of two situations: 1) when File-AID detects an unrecoverable error 2) when File-AID itself terminates abnormally In both situations, File-AID intercepts the abend and displays an error screen. In the first case, a message is displayed describing the unrecoverable error encountered. In the second case, the system and user abend codes are displayed. The first keyboard interaction on the error display screen causes the ISPF abnormal termination screen to be displayed. File-AID attempts to close all open files prior to returning control to ISPF. DATASET SECURITY File-AID is completely compatible with any data security software your installation may have (Ex. RACF, CA-ACF2/TOP Secret, etc). File-AID processing does not circumvent your security software in any way. File-AID provides your installation with the capability of creating its own security exit routine that File-AID will call during its processing. This enables your installation to limit access to certain datasets. Following are some examples of the optional security exit routine uses: To allow only authorized users to browse and/or edit selected data files
If you require information on your installations security exit routine, contact the person responsible for File -AID at your installation. In addition to the security exit, an audit exit is provided that can be customized for various uses including: - To force the creation of an audit trail when option 2 of File-AID is used to edit selected data files, and/or to force the printing of an audit trail report upon completion of the data file updates - To log all or selected dataset updates to the SMF log.
AUDIT TRAIL FEATURE When you use option 2 of File-AID to edit a data file, you may specify that File-AID capture all of your update activity in an audit trail dataset. Every insert, repeat, delete, copy, typeover, and CHANGE command you perform causes a before and/or after image of the record(s) affected to be written to the audit trail dataset. When you complete your edit session, a screen is displayed giving you the option to print, delete, or keep the audit trail. If you specify that the audit trail be printed, a batch job is submitted which produces a formatted audit trail report. File-AID also provides your installation with the ability to force the creation of an audit trail during any users edit session through an audit exit routine. This is especially useful, for example, if your installation wants to ensure that an audit trail is created whenever File-AID is used to edit certain sensitive data files. When the edit session is complete, the audit exit routine can also be used to force the automatic submittal of a batch job to produce the audit trail report, thereby ensuring that a record of the edit session is printed. In addition to the audit trail facility, File-AID provides the option to log all dataset updates to the system SMF datasets. If you require information on how your installation may be using any of these audit trail facilities, contact the person responsible for File-AID at your installation. COMPRESSION/ENCRYPTION EXIT File-AID provides your installation with the capability of creating its own compression/encryption exit routine that will act as an interface between File-AID and any compression/encryption software you may have (e.g., SHRINK or DATA PACKER). This allows you to work with data files that are stored on disk or tape in a compressed or encrypted format in all File-AID options. File-AID invokes the compression/encryption exit for data files only, not for record layout datasets, record/layout cross references, or selection criteria. If you require information on your installations compression/ encryption exit, contact the person responsible for File -AID at your installation. DOUBLE-BYTE CHARACTER SUPPORT File-AID will automatically detect and present DBCS data characters if your terminal type is set to 3277KN or 3278KN from option 0.0.1 of File-AID, or option 0.1 of ISPF (ISPF terminal characteristics). There are two ways File-AID presents data. The two ways are presented in sequence, or may be selected by number: 1 Formatted data presentation (Formatted and Vertical modes) 2 Full-screen data presentation (Character mode) File-AID assumes that all character fields contain a mixture of EBCDIC data and Double-Byte Character Set (DBCS) data. The DBCS characters are enclosed with shift-out (X0E) and shift-in (X0F) characters. For PIC G(nn) fields in COBOL or GRAPHIC(nn) fields in PL/I File-AID assumes that the field contains only Double-Byte Character Set (DBCS) data. DBCS data does not include shift-out (X0E) and shift-in (X0F) characters and should be an even number of bytes in length. Note: X0E and X0F are for IBM sites. Other platforms such as FSP andHitachimay use other representations for shift-in and shift-out. FULL-SCREEN DATA PRESENTATION When data is presented without COBOL or PL/I record layouts (three-line hexadecimal or character format), each character line displayed is considered a character field. File-AID assumes that all character fields contain a mixture of EBCDIC data and Double-Byte Character Set (DBCS) data. The DBCS characters are enclosed with shift-out (X0E) and shift-in (X0F) characters.
Use caution when entering DBCS characters to ensure that the shift-out and shift-in characters are accounted for and will not overlay other data values unexpectectly. The commandHEXONis useful to view the location of the shift bytes. Double-byte character support File-AID will automatically detect and present DBCS data characters if your terminal type is set to 3277KN or 3278KN from option 0.0.1 of File-AID, or option 0.1 of ISPF (ISPF terminal characteristics). There are two ways File-AID presents data. The two ways are presented in sequence, or may be selected by number: 1 Formatted data presentation (Formatted and Vertical modes) 2 Full-screen data presentation (Character mode) FORMATTED DATA PRESENTATION File-AID assumes that all character fields contain a mixture of EBCDIC data and Double-Byte Character Set (DBCS) data. The DBCS characters are enclosed with shift-out (X0E) and shift-in (X0F) characters. For PIC G(nn) fields in COBOL or GRAPHIC(nn) fields in PL/I File-AID assumes that the field contains only Double-Byte Character Set (DBCS) data. DBCS data does not include shift-out (X0E) and shift-in (X0F) characters and should be an even number of bytes in length. Note: X0E and X0F are for IBM sites. Other platforms such as FSP andHitachimay use other representations for shift-in and shift-out. FULL-SCREEN DATA PRESENTATION When data is presented without COBOL or PL/I record layouts (three-line hexadecimal or character format), each character line displayed is considered a character field. File-AID assumes that all character fields contain a mixture of EBCDIC data and Double-Byte Character Set (DBCS) data. The DBCS characters are enclosed with shift-out (X0E) and shift-in (X0F) characters. Use caution when entering DBCS characters to ensure that the shift-out and shift-in characters are accounted for and will not overlay other data values unexpectectly. The commandHEXONis useful to view the location of the shift bytes
Endevor:-
ENDEVOR SOFTWARE
use Endevor for
Source control
To ensure that we always work with the latest version of the source
Endevor Search
To search for a string in a large list of sources
SCL generation
This is required at the time of migration
Endevor environments
Alternate/Fix environment Test environment Release environment Demo test environment Demo production envmt.
DEFAULTS DISPLAY FOREGROUND BATCH PACKAGE BATCH PACKAGE USER MENU TUTORIAL CHANGES EXIT
SHIP PRODUCTION
Option B Option C
will give a source listing of the element as it currently exists in the region specified can be used to get details of changes made to the current source with respect to the previous version Can be used to get details of all changes ever made to the source. For each line of the source code, the appropriate version number is indicated at the extreme left Can be used to get information about the current status of the source (i.e. whether it has been retrieved, if so, by whom and on what CCID etc.)
Option H Option M
can be used to get details of changes made to the current (selected) version with respect to the previous version can be used to get details of all changes ever made up to the selected version. For each line of the source code, the version number is indicated at the extreme left
currently existing in endevour (e.g versions of the same source may be existing in
Retrieval
1. For purposes of modification, we will normally retrieve elements from Production.
FROM ENDEVOR:
EXPAND INCLUDES ===> N (Y/N) SIGNOUT ELEMENT ===> N (Y/N) OVERRIDE SIGNOUT ===> N (Y/N) REPLACE MEMBER ===> N (Y/N) P PROD
SUBSYSTEM ===> EAS ELEMENT TYPE STAGE COMMENT ===> IOINTEG1 ===> COBOL ===> P ===> S SHIP
TO ISPF LIBRARY: PROJECT ===> EASV11 LIBRARY ===> QFIX TYPE ===> COBOL
WHERE PROC GRP EQ ===> BUILD USING MAP ===> N (Y/N) FIRST FOUND ===> Y (Y/N)
MEMBER ===>
Endevor Search
Using Endevor Search
The search option can be used to search a large list of sources for the occurence of a given string. Follow the steps as given below: 1. Select the desired endevor environment (Usually RELEASE). 2. Select the BATCH option.
3. Select the BUILD SCL option giving a temporary member name. 4. Select option 11 (To list elements). 5. Enter the the partial names of the of the elements you wish to scan, and the corresponding type. 6. Press enter- SCL will be generated; then press F3 7. Again press F3 to return to the Batch Options Menu 8. Enter option 3 to Submit the SCL 9. Scan the held output under DDNAME C1MSG1 10. Search for the return code of 0000. Any element which has 0000 against it has the string you are looking for. (e.g. IO* & COBOL); Set Display List to N; Select Option L; Type in the string to be searched for.
1 BUILD SCL Build batch SCL actions 2 EDIT 3 SUBMIT Edit request data set Submit job for batch processing
4 VALIDATE Check request data set for syntax errors 5 BUILD JCL Enter additional JCL to be included with the job
REQUEST DATA SET: PROJECT ===> AGP2269 GROUP TYPE ===> SOURCES ===> COBOL APPEND ===> N (Y/N)
===> ===> ===> List Element Action OPTION ===> L ELEMENT DISPLAY OPTIONS: blank Element list L LIST element action S Summary B Browse M Master C Changes H History
FROM ENDEVOR:
SUBSYSTEM ===> EAS ELEMENT TYPE STAGE ===> IO* ===> COBOL ===> P S SHIP
P PROD
TEXT STRING: ===> CONSOLLT SCAN COLUMNS: START ===> END ===>
ACTION TO BE GENERATED WHEN LIST IS CREATED ===> WRITE LIST TO OUTPUT DATA SET ===> N (Y/N) WHERE COMPONENT EQ ===>
SCL Generation
SCLs are generally used to migrate sources from the Development region to TEST. The steps involved in the preparation of an SCL are listed as the following
1 BUILD SCL Build batch SCL actions 2 EDIT 3 SUBMIT Edit request data set Submit job for batch processing
4 VALIDATE Check request data set for syntax errors 5 BUILD JCL Enter additional JCL to be included with the job
REQUEST DATA SET: PROJECT ===> AGP390 GROUP TYPE ===> QFIX ===> SCL APPEND ===> N (Y/N)
JOB STATEMENT INFORMATION: ===> ===> ===> ===> Add/Update Elements OPTION ===> A
A Add an element
U Update an element
TO ENDEVOR:
GENERATE ELEMENT
SUBSYSTEM ===> EAS ELEMENT TYPE STAGE: ===> DC1005 ===> COBOL I
DELETE INPUT SOURCE ===> N (Y/N) NEW VERSION OVERRIDE SIGNOUT ===> ===> Y (Y/N)
===> CIINCL
===> N (Y/N)
COMMENT
===>
FROM ISPF LIBRARY: PROJECT ===> EASV11 LIBRARY ===> LR11 TYPE ===> COBOL
FROM OTHER PARTITIONED OR SEQUENTIAL DATA SET: DATA SET NAME ===>
Add/Update elements
1. Use option A when you are adding new elements to the SCL. The same option will hold even when we are appending members to an existing SCL. 2. Ensure that the member names match in the TO and FROM libraries. This is very importa nt ! 3. The Processor group field will depend on the type of program. This field is mandatory when new sources are being added to the system. Use the following key:
Sorce Type Batch COBOL Program CICS COBOL Program Copy Book Control card Bind card Batch to Module (TDM) CICS to Module (TDM) Batch to Module (without TDM) CICS to Module (without TDM)
Processor Group CIINBL CIINCL CPYNNN SRCNNS BNDSUBX CIITBL CIITCL CIIDBL CIIDCL
NOTES
After building the SCL, it is advisable to manually browse it. For this, use the EDIT option shown in the first screen. Check for : 1. Mismatched member name 2. Repeated entries for same element 3. Wrong Processor group
Asset Allocation
The practice of deciding how investments are divided among asset categories.
Cash Equivalents
Investments that are fixed income securities with relatively short maturities (for example, less than one year). Examples of this are a money market fund and a treasury bill.
Counterparty Risk
The risk that the other entity in a financial agreement will be unable to fulfill the obligations of that transaction.
Custodian
Bank of other financial institution that keeps custody of stock certificates and other assets of a mutual fund, individual, or corporate client.
Equity
A type of security representing ownership possessed by shareholders in a corporation. An equity investment differs from a debt investment in that the issuer makes no promise to pay the investor current income or any guaranteed amount at a future date. Additionally, although they are owners, shareholders do not usually participate actively in the management of the corporation, other than to elect directors, select auditors, and to vote on matters that may be required by law.
Fixed Income
A type of security that pays a fixed rate of return. Examples of this include government, corporate, or municipal bonds, which pay a fixed rate of interest until the bonds matures, or preferred stocks, which pay a fixed dividend.
Investment Trusts
A type of investment company that pools money from it shareholders. Investment trust is also known as a closed-end investment company, meaning only a fixed number of outstanding shares is offered
Mutual Fund
A type of investment company that pools money from its shareholders. A mutual fund is also known as an open-end investment company, meaning that there is a continuous offering of new shares and redemption of outstanding shares
Value Chain
A value chain breaks down an industry to its value activities to understand the behavior of costs, and the existing and potential sources of differentiation. It is used to compare and contrast competitors in an industry.
Commercial Banking
The commercial bank meets the financing and cash management needs of business customers. Customers range from small businesses to multi-national corporations in industries such as manufacturing, wholesaling, retailing, service or agricultural entities. The commercial bank provides credit and non-credit products and services to customers.
Commitment Fees
Fees paid by a customer in return for the banks le gal commitment to lend funds that have not yet been borrowed by the customer. The customer pays a fee to ensure that additional funds will be available to them if needed.
Credit Scoring
A standardized credit rating system, which analyzes applicant criteria such as income, personal characteristics and other outstanding debt. The system produces a credit score intended to be indicative of a borrowers ability to repay a loan.
Lease
A contract granting the use of real estate, equipment, or other assets over a fixed period of time in exchange for payment. The borrower pays for the privilege of using the asset, and the ownership of the asset is usually transferred to the borrower at lease end.
Letter of Credit
A bank guarantee of payment for a buyer or seller of goods. Payment for goods is guaranteed and will be made when the terms of a contract have been met. Payment is also guaranteed if the applicant for the letter of credit fails to uphold the terms of the contract.
Margin
The amount of funds that must be deposited wh en purchasing securities. Also, the equity in an investors account.
Matched Funding
A process of matching maturing liabilities (customer deposits) with maturing assets (loans or investments) to manage the costs associated with fluctuating interest rates. As an example, a bank would try to fund a 3-year loan with a 3-year deposit to lock in the interest rate it will earn for the three-year period.
Relationship Manager
Relationship managers typically serve as the primary contact between the bank and customers. Relationship managers may also coordinate services from other areas of the bank for cross-selling opportunities.
Securitization
The process of aggregating debt instruments, such as loans, in a group and issuing stocks or bonds backed by the group.
Spread
Income earned after interest expense. A bank earns interest income on its loans (for example, 9% lending rate) and incurs interest expense on the funds used to make loans (for example, 3% paid to depositors). The difference between the two rates is the banks spread (9% 3% = 6% spread).
Term Loan
A loan that is made to finance an asset over a period of time. The banks commitment is usually long term (greater than 1 year) and is usually a secured loan.
Adjustable-Rate Mortgage
A property loan that is subject to periodic rate adjustments. The exact method, frequency, and basis for the rate change are based on the investment it is tied to, which is usually a widely published market/base rate of interest or index.
Authorization
Process that ensures that the credit card and cardholder are valid and have enough credit to pay for the item. An authorization occurs electronically at the point of sale, taking only seconds to complete.
Bad Debt
Open account balance or loan receivable that is proven uncollectable and written off.
Charge Card
A short-term funding mechanism. Charges must be paid in full at the end of the monthly cycle. An example is a corporate charge card.
Collateral
An asset pledged to a lender until a loan is repaid. If the borrower fails to make payments as required, the lender has the legal right to seize the collateral and sell it to pay off the loan.
Credit Scoring
A standardized credit rating system, which analyzes applicant criteria such as income, personal characteristics and other outstanding debt. The system produces a credit score intended to be indicative of a borrowers ability to repay a loan.
Fixed-Rate Mortgage
A property loan in which the payback rate does not vary with market conditions; it is constant over the life of the loan.
Installment Loan
A consumer loan that has a predetermined loan maturity date (the date the loan is to be paid in full) and repayment schedule.
Loan-to-Deposit Ratio
Percentage representing a banks total amount of outstanding loans to the amount of deposits.
Overdraft Credit
A line of credit attached to a checking account. When a customer withdrawals more money than in his account, the extra amount is covered by the overdraft credit. The customer pays interest on the overdraft amount.
Revolving Credit
Loan amount requiring monthly payments of less than the full amount due, with the balance carried forward subject to additional interest.
Branch/ATM
For some banks, branches are the primary distribution channel for selling products and services. Although differences exist among banks and across regions, most branches offer a range of products and services, including deposit accounts, transactional services, lending services, investment services, and insurance.
Commission
Fee paid to sales personnel for executing a trade based on the number of shares traded or the dollar amount of the trade.
Compensating Balance
Minimum balance required by a bank on certain deposit accounts. Banks require customers to keep these balances as a stable source of funds for the bank, and impose financial penalties if the account goes below the minimum requirement.
Computer Switch
ATM back-end equipment that allows network banks to share customer account information. These switches allow customers to use any participating ATM, and allow the network banks to verify funds for non-customers.
Deposit Accounts
These accounts allow customers to deposit funds that the bank must repay the customer at some future date. Two major types: 1. Funds committed to the bank for a specified period of time. In return, the bank offers a higher interest rate relative to other types of deposits. A certificate of deposit is one common form. 2. Funds committed to the bank, which the customer has the option to withdraw at any time. A savings account is the most common form.
Insurance
Most countries have an independent insurance industry. In many countries, however, the insurance and banking industries are merging, resulting in the selling of insurance products in banks. Some of these products include life insurance, property insurance, and casualty insurance.
Investment Services
Banks offer services to help customers invest their excess funds. Some of these services include brokerage services, mutual funds, annuities, personal trust, and asset management.
Lending Services
Banks provide funds to customer while charging customers interest for the use of those funds. Some examples include mortgages, home equity loans, overdrafts, and credit cards.
Premium
Fee paid to a bank or insurance provider for insurance coverage.
Transaction Services
These accounts allow customers to deposit funds with the intention of making non-cash payments in the near future, usually with instruments such as a check or debit card. Two major types: 1. Funds may be withdrawn on demand without advance notice. A checking account is the most common form. 2. Some accounts may carry a market interest rate and allow the depositor limited check-writing privileges. A money market deposit account is one common form.
Transfer Pricing
The internal charge to a business unit for goods or services provided by another business unit. An example of transfer pricing would be the deposits line of business charging a lending division for using customer deposits as the source for loans.
Electronic Banking
Electronic banking is one type of distribution channel used to deliver products and services to customers. It brings the bank to the customer-a strategy for penetrating different customer segments, encouraging customer loyalty, and reducing costs. Within electronic banking, several different types of delivery mechanisms exist, such as VRU, digital TV, mobile phone, kiosk, PC, and the Internet.
Digital TV (DTV)
To leverage the technology of interactive TV, some banks use the platform of the digital TV operators, including satellite and cable, to offer home banking services. DTV combines video, images, sound and textual information. The navigation requires the use of only five keys on the standard pay-TV remote control. Customers can browse through account information directly on the TV and perform transactions, such as transfers, blank check orders, or financial product subscriptions.
Financial Institutions
Financial Institutions include banks, insurance companies and brokerage houses.
Internet Banking
Internet banking offers the ability for customers to conduct basic bank transactions (for instance, balance transfers and account inquiries) through direct dial-up connections to the bank. Unlike PC banking where access is limited to a PC equipped with the banks software, Internet banking allows customer access to information and services from any location with an Internet connection. The goal for a banks Web site is to provide many, if not all, of the services offered at a branch -transactions, account information, advice, administration, and even cross-selling. The interactive nature of the Web not only allows banks to enhance these core services, but also enables banks to communicate more effectively and strengthen customer relationships.
Kiosk
The kiosk multimedia application is based on a virtual branch metaphor. Existing or potential customers can enter the branch by touching the doors on the kiosks touch screen. Inside the virtual bank branch the customer can obtain information and go through the sales process of products. The customer will be guided by a virtual host and sales personnel
through integrated video sales person and promotion video clips. The application offers a full range of retail banking products and services. In cases where real signature is required by law, the customer can print out the application for signature and submission.
Mobile Phone
Banking using the mobile phone is similar to using a touch-tone phone. Customers can access basic transactions such as check balances, loan rates, checks paid, deposit rates, and credit card payments. Many providers also offer Internet banking over Internet enabled mobile phones.
Origination
Origination refers to the customer acquisition process.
PC Banking
Customers can access accounts by installing the banks application on the PC. This allows customers to access account information, pay bills, transfer funds, or to purchase investments while online. Some major providers of personal management (PFM) software are partnering with banks to offer additional services. This software may offer additional features such as creating account registers and checkbooks, balancing accounts, setting up loan amortization schedules, creating budgets, tracking investment performance, and estimating taxes.
PDA
Banking using a wireless PDA (personal digital assistant) offers all the capabilities of banking on the Internet (e.g., check balancing, transferring balances, paying bills, etc.), but has a scaled down user interface. It is very similar to doing Internet banking over a mobile phone.
CallCenter
Call centers are lower cost delivery channels than branches to maintain high quality customer service. Call centers allow other delivery channels, such as branches, to focus on marketing and selling instead of service. Major functions supported by the call center include credit card services (such as transaction and balance inquiries), retail and commercial account information (such as transfers or payments), basic customer service (such as change of address) and website support.
Inbound
Telephone calls made from either a customer or an employee to the call center.
Outbound
Telephone calls made from the call center to a customer or potential customer.
Distribution Channels
Banks use a variety of channels to manage products and services. Banks must define policies for new and existing channels, determine the distribution strategies, support each channels operations, and manage the branch network across regions. While the branch is the most visible distribution channel, alternative channels, such as Internet banking and ATMs have grown substantially in the past decade. New channels have emerged due to increasing customer sophistication in
technology and product knowledge, competition for new customers, the need to lower operating costs, to increase time in the branch for commercial activities and evolving technology.
Multi-Channel Strategy
Retail banks use a multi-channel approach to serve a wide range of customers. Channels include electronic banking, branch, ATM and call centers. This diversification increases bank revenues while lowering bank costs.
Private Labeling
A banks purchase of a product from a third party for use and sale under the banks own name. Other banks can purchase the same product and private label it for their own uses. Although private labeling reduces product development costs, banks usually choose to develop products internally, rather than through private labeling, since new products often differentiate banks from their competition.
Product Bundling
Bundling offers a complementary group of products or services to a customer. Products and services may be bundled as a way to increase sales of a particular product (such as, bundling a poorly selling savings account with a popular checking account), or to target specific market segments (such as a group of products targeted at young professionals).
Risk Management
Risk management is the framework and related infrastructure by which banks plan for, acquire, and monitor risk to achieve superior performance. Risk management integrates human resources, technology, capital, and target marketing to balance risk against reward. Categories of risk include economic, credit, liquidity, and operational risk.
Asset-Liability Management
Matching the maturity of deposits with the length of loan commitments to avoid adverse affects from changes in interest rates.
Business Risk
Banks analyze a business customers ability to repay a loan. Loan review and approval by more than one individual helps offset business risks.
Credit Risk
The uncertainty of realizing the return of principle and the expected reward from a customer or portfolio of customers.
Credit Risk
The uncertainty of realizing the return of principle and the expected reward from a customer or portfolio of customers.
Individual Risk
Banks have replaced the manual review process for individual and small business loans with new analytical tools. Credit scoring and behavioral modeling are used to standardize the evaluation of loan applications and to project future risks.
Industry Risk
Loans are classified by industry, and limits are established on loan amounts outstanding by industry to offset industry risks.
Liquidity Risk
The ability to convert assets into cash or cash equivalents without experiencing significant loss.
Analysis of non-performing and problem loans, including probability of default, loss rates by risk rating, recovery rates, and time from origination of the loan to non-performing status.
Non-performing Loans
Loans for which customers are not making scheduled payments. Commercial loans that are 90 days past due and consumer loans that are 180 days past due are usually classified as non-performing.
Operational Risk
Risk of loss associated with the failure to execute transactions due to: 1. Inadequate controls 2. Operating errors 3. Inaccurate information 4. Ineffective management 5. Natural disaster 6. Fraud 7. Regulatory issues 8. Legal considerations
Risk Appetite
Industry term used to describe the general level of risk acceptable to a bank. A small risk appetite would mean that a bank would have little interest in a risky transaction.
Risk Rating
A rating system based on a scale of loan performance and loss experience. Limits are established for each rating level for individual, business, industry and country risks. Stress Testing and What If Scenarios Simulation of the impacts of trends and events (such as, interest rate changes, regulatory changes, economic growth, currency fluctuations) on a loan portfolio.
Activity-based Costing
A method of determining the total cost of providing a service to customers. These costs are aligned to associated revenues by product, customer, and channel. Finance and corporate planning uses activity-based costing information to help determine product prices and set interest rates on savings products.
Capital Adequacy
A measure of an institutions capital (equity) in relation to its asset base. A higher capital adequacy means a stronger abil ity to absorb losses. A banks capital usually ranges from 2-12% and varies based on factors, such as size and regulatory requirements.
Credit Quality
A measure of the quality of an individual loan or a loan portfolio. Good credit quality means that the customer continues to make full loan payments on time and is not at risk for defaulting on the loan.
Efficiency Ratio
A measure of how well a bank is managing its non-interest expenses. The lower the efficiency ratio, the better the bank is performing. This ratio is measured by dividing non-interest expense by the sum of the net interest income and the noninterest income. For banks, typical efficiency ratios are .55 or lower.
Non-interest Income
Income earned from non-lending services offered by the bank. Some examples include service fees and stock exchange commissions. Non-interest income is usually one-third of a banks total income.
Banking Services
The goal of banking services is to provide quality customer service, and efficient and accurate processing of information and materials.
Acquiring Bank
The financial institution where the check is deposited into the payees account.
Check Truncation
Process in which the information on a check is converted into electronic images. Checking account customers receive images of checks they have written, rather than the physical check.
Issuing Bank
The financial institution that issues the payors check.
Off-line Processing
ATM or debit card reader does not have a direct link to the customers account file. Instead, the purchase information is captured for later processing, and does not immediately post to the account. Few off-line systems are used today.
Online Processing
ATM card or debit card readers are linked directly to the customers files, which contain their individual account informati on. At the point of sale, these transactions link directly to the bank to determine whether the customer has funds to cover the purchase or a cash advance.
Retail payment system that substitutes an electronic transfer of funds for cash, checks, or drafts in the purchase of retail goods and services.
Smart Cards
Credit cards with microcomputer chips. Smart cards are a recent trend that will have a substantial impact on future banking. These cards offer a secure, personalized connection to Internet shopping and banking and are being considered for multiple purposes across different industries.
Private Banking
The traditional private banks target high net worth (HNW) individuals and provide customized, personal services for these clients. Although the minimum requirement varies among banks, they typically define this specific customer segment as individuals with assets under management of USD one million or more. Products offered include credit and deposit products, investment products, estate and financial planning services, and trust products.
Advisory Management
Accounts that require clients authorization before executing investment decisions.
Discretionary Management
Accounts that give the relationship manager full authority to make investment decisions.
Bank Performance
Bank performance is important to internal and external stakeholders. A banks performance is often compared to other banks of similar size and product offerings.
allow banks to limit the adverse affects of rate movements, are used to manage interest rate risk. Matching foreign currency loans with deposits in the same currency when appropriate is one way to manage exchange rate risk.
Efficiency Ratio
A measure of how well a bank is managing its non-interest expenses. The lower the efficiency ratio, the better the bank is performing. This ratio is measured by dividing non-interest expense by the sum of the net interest income and the noninterest income. For banks, typical efficiency ratios are 55% or lower.
Factoring
A type of financial service whereby a company sells its accounts receivable to a financial institution. The financial institution collects the debt or payments for the receivables, and assumes the risk that the receivable may not be repaid.
Inflation
The rate at which the general level of prices for goods and services is rising.
Interest Income
Net income earned from the banks lending activities, such as commercial loans, credit cards, mortgages, etc. Two -thirds of a banks total income is usually derived from net interest income.
Non-interest Income
Income earned from non-lending services offered by the bank. Some examples include service fees and stock exchange commissions. Non-interest income is usually one-third of a banks total income.
Provision
Amount charged against the profit and loss statement (income statement) to reserve against loan losses or losses/charges. Bank management will make a provision for losses when they believe they will be unable to collect the loan amounts due from customers. When the loan is officially not repaid, the loan amount is written off. If the original provision was insufficient to cover the loss, an additional charge against income will be taken. If the original provision was greater than the write-off, the bank will either credit income or apply the provision against another loan.
Unemployment rate
Percentage of a countrys workforce actively looking for work, but unable to find jobs. This metric is one of the most closel y watched government rates, because it has long been thought to often give t he clearest indication of the economys direction. A rising unemployment rate is seen as a sign of a weakening economy, which may call for an ease of government monetary policy. A drop in the employment rate, on the other hand, shows that the economy is growing, which may spark fears of high inflation, in which the government may increase interest rates. While this has proven true quite often over the years, this theory did not hold true in the 1990s when the economy grew rapidly, yet both the unemployment rate and inflation remained below 6% for many years. Thus, rapid growth and the low unemployment rate did not spark fears of high inflation and increases in interest rates during much of the 1990s.
Write-off
Charging an asset amount, such as uncollected debt, to expense or loss. Bank management will make a provision for losses when they believe they will be unable to collect the loan amounts due from customers. When the loan is officially
not repaid, the loan amount is it written off. If the original provision was insufficient to cover the loss, an additional charge against income will be taken. If the original provision was greater than the write-off, the bank will either credit income or apply the provision against another loan
TELECOMMUNICATION
Telecommunication refers to long distance communication. The Greek word tele means far off. At present, such communication is carried out with the aid of electronic equipment such as the radio, telegraph, telephone, and television. However, in earlier times, smoke signals, drums, light beacons, and various forms of semaphores were used for the same purpose. The information transmitted can be in the form of voice, symbols, pictures, data, or a combination of these. The physical equipment for a telecommunications system includes a transmitter; one or more receivers; and a channel or means of communication such as air, wire, cable, communications satellite, or some combination of these.
Making a call
The telephone cannot by itself set up a call between two subscribers. Most of the functions occur in cooperation with the telephone switching equipment (exchange). When an individual lifts the cradle, a signal is sent to the exchange indicating that the user wants to make a call. This signal is known as the hook off signal. The signaling process between the exchange and the telephone set commences in this manner. The exchange checks for certain parameters to authenticate the subscriber, and sends the dial tone to the users telephone. When the user dials a number, the exchange gets the destination address of the called subscriber. The numbering system within the exchange routes the call to the called subscriber. The exchange then determines the status, whether available or busy, of the called subscriber. Based on the status, the exchange sends either a ring back tone or a busy tone to the calling subscriber and the ring tone to the called subscriber. If the calling subscriber is available, a voice path is created and the two parties can now communicate with each
It is practically impossible to connect all telephones to each other using cables. This led to the introduction of switching systems, commonly known as exchanges. With the introduction of switching systems, the subscribers are not directly connected to each other. Instead, all subscribers are connected to some switching system. Therefore, only one link is established between the subscriber and the switching system. When a subscriber wants to call another subscriber, a connection is established between the two at the exchange. This helps in administration, maintenance, and overall control of the telecommunication network.
Automatic Exchanges
Due to the disadvantages of manual exchanges, automatic exchanges were invented. Automatic exchanges can be classified as Electromechanical and Electronic. The electromechanical exchanges transmitted sound in the form of analog signals. Further, the electromechanical switching systems can be classified into Strowger (Step-by-step) exchange Crossbar exchange
Electronic Exchanges
The crossbar systems were found to be slow in call processing. It was realized that components of switching systems could be replaced by a single digital computer. In electronic switching systems, a computer performs the control functions. Hence, these systems are called Stored Program Control (SPC) Systems.
Stored Program Control Stored-program control is a broad term designating switches where common control is carried out to a greater extent or entirely by computer hardware. Control functions can be carried out entirely by a central computer, or partially or fully by distributed processing.
There are four basic functional elements in the SPC switching system.
Switching matrix: The switching matrix is an abstraction of a switch. The function of a switch is
to connect the calling and the called party. The method of connection differs based on the topology used. The infrastructure required for the connection is called the switching matrix.
Call store: This is a temporary storage of incoming call information ready for use on command
from the central processor. The call store is also referred to as scratch pad memory. It also contains data on the availability and status of lines, trunks, service circuits, and internal switch circuit conditions.
Program store: The Program store contains the software needed for the operation of the
switching system.
Central processor: The Central processor is the nerve center of the switch. It controls the
operation of various entities such as the dial tone detector, the ring generator, and the switching matrix.
Digital Technology
The idea of digital technology is to convert analog signals to digital 1s and 0s. Sound is a set of analog events, which ca n be represented in a curve. A continuous analog wave can be converted to an equivalent digital mode. This process of modulation is called Pulse Code Modulation (PCM). The PCM Process is illustrated in the figure below.
A single conversation does not utilize bandwidth to the maximum extent. To utilize the bandwidth to the full extent, you can combine many such conversations to transmit through a same line by the process of Multiplexing. The conversion of an analog voice signal for digital transmission involves three steps.
Sampling: Sampling is the process of taking readings (or samples) on t he speech curve. It is
important to establish a set of discrete times at which the input waveform is sampled. The Nyquist Criterion (Nyquist theorem) specifies how frequently readings need to be taken. Thus, a suitable sampling frequency is determined. The result is a Pulse Amplitude Modulated (PAM) signal, where each pulse corresponds directly to the amplitude on the speech curve.
Quantization: Quantization assigns a binary value to each voltage sample. A PAM waveform
could have an infinite number of distinct voltage values between the maximum and minimum values of the voltages. To assign a different binary sequence to each voltage value, a code of infinite length would be required. To avoid this, we go in for quantization. The number of bits used for transmission depends upon the number of quantum values. For example, eight bits are sufficient to form a unique code for each quantum value when the number of quantum values is 256 (2^8 = 256). Of these, the first bit is used to denote the polarity of the sampled signal. The equipment needs only to differentiate between these digits, which are sent in the form of pulses. During quantization, the Quantizer o Limits the input signal amplitude between upper and lower voltage values the dynamic input range of the ADC. o Sets a given number of discrete values between the maximum and minimum voltage limits.
Compares each sample with a set of quantum values in turn and assigns it to the one it approximates.
Thus by definition, all samples in an interval between two quantum levels are deemed to have the same value. The output of the ADC is in serial digital format, which is a unipolar Binary sequence of 0s and 1s. This sequence cannot be directly fed to any media such as PCM, Optical Fiber Cables (OFC), or Microwave (MW). Therefore it is given to the Line Coder, which encodes it in one of the following formats: AMI, HDB3, CMI, RZ, or NRZ. Coding: PCM is not specially designed to digitize speech waveforms. Speech waveforms have a lot of redundancy that can be used to design coding schemes. Speech signals typically have nonuniform amplitude distributions, sample-to-sample correlation, periodicity or cycle-to-cycle correlation, and speech pauses or inactivity factors. PCM outputs very high bit rates, which consume a lot of bandwidth. To overcome this problem, new voice coders such as ADPCM and LPC were developed. They give much lower bit rates and are therefore bandwidth efficient.
Numbering Plan
With the increase in number of subscribers, it became necessary to identify each subscriber to set up the call faster. The numbering plan provides every subscriber and every service including call forwarding, call waiting and call queuing, in the telephone network with a unique and simple code, which allows automatic call set up in the network.
It is necessary that each subscriber be able to call any other subscriber. This requires each subscriber to have a unique code. Also, for the convenience of the subscriber and the telephone exchange, a simple code is needed.
Create subscriber numbering series with as few digits as possible Create a uniform and simple method of dialing numbers for the whole country Create simple number codes for specific services, which are the same throughout the country Simplify coordination with other numbering plans
Country code: The Country code is the combination of one, two, or three digits characterizing
the called country. The first digit in the country code is the zone code of the zone in which the country lies. For example, in zone 9,India has the country code 91 andMaldives 960. The zone code 9 is the first digit in the country codes of bothIndia and theMaldives.
Area/Trunk code: The Area or Trunk code is the digit or combination of digits that identifies a
particular numbering area of the called subscriber in a country. This code determines the routing for a trunk call and the charge for it. <LI</LI>Exchange
Code: The exchange code identifies a particular exchange within a numbering area.
Subscriber Line Number: The subscriber line number is used to select the called subscriber line at the terminating exchange. In CCITT terminology, the combination of the exchange code and the subscriber line number is known as the subscriber number. This is the number listed in the telephone directory.
PABX (Private Automatic Branch Exchange) PABX is a device installed on the customers premises, that enables switching of multiple incoming and outgoing lines between multiple internal phones. Business subscribers often have specific requirements for their telephone numbers. They must be simple to remember, and must also allow direct access to individual extensions after dialing the basic number. For example, at Sharda center, you would want to allow callers to directly dial the extension of a particular employee after calling the Sharda number. From the point of view of telephone administration, the PABX (Private Automatic Branch Exchange) is a subscriber with several extensions, which is accessed by a number. Routing Routing is the process of delivering a message across one or more networks via the most appropriate path. There are basically two main methods of routing:
Fixed routing: The call is routed based on a pre-defined route. There is no change in the route regardless of the time of the call, availability of the route, or call statistics.
Dynamic routing: It is necessary to find optimal routing paths for the transport of information. In dynamic routing, the routing pattern varies based on factors such as:
Time: Calls are routed depending on the time of the day. For example, normally you may be using route b to route calls. However, between 8 to 10 a.m, you may decide to route 50% of the calls made via route a and 50% via route b. These routing patterns are pre-planned and are implemented at a fixed time of the day. State: Routing patterns can be varied based on network information collected by toll exchanges. For example, if a certain route or part of it is found busy, the toll exchange can route your call via another route. Event: Certain events such as natural calamities or special occasions such as Mothers Day can affect the call statistics. Routing patterns are updated locally based on call statistics. Once you dial a number, all exchanges involved in routing the call have to communicate amongst themselves. This is done through the process of signaling.
Introduction Signaling
In telephony, signaling refers to the passing of information and instructions from one point to another, relevant to the setting up of a telephone call. To initiate a call, the caller lifts the handset off the hook. This off-hook state is a signal to the exchange to be ready to receive the number of the called subscriber. As soon as appropriate receiving equipment is connected to the line, the exchange signals the dial tone to the calling subscriber. The subscriber can then dial the destination number. The subscriber receives either a ringing signal, an engaged or busy tone signal, or an equipment busy tone indicating congestion between the called exchange and the calling line. These are signals with which the telephone subscribers themselves are concerned. Signaling involves sending signals between various switching systems, transmission systems, and subscriber equipments in a network. Signaling Tones In older exchanges, information is passed via a rotary dial by a series of makes and breaks of the subscribers loop, interrupting current flow. In modern exchanges, voice-frequency musical tones are sent to the exchange as push buttons are pressed. These tones are usually called DTMF (Dual Tone Multi-frequency) as each time a button is pressed, two tones are simultaneously sent out to the line. Distinctive signaling tones are provided in all automatic exchanges. Typically, there are four distinct signaling tones:
Dial Tone: The Dial tone is used to indicate that the exchange is ready to accept the digits dialed by the subscriber. The subscriber should start dialing
the number only on hearing the dial tone. Otherwise, the initial digits of the dialed number may be missed by the exchange.
Ringing Tone: When the line of the called subscriber is obtained, the exchange sends the ringing current to its telephone set. Simultaneously, the exchange sends a Ringing tone to the calling subscriber too. The ringing tone and the ringing current are two similar, but independent quantities, having a double-ring pattern. Therefore, it is possible that the calling subscriber hears the ringing tone, whereas the called subscriber may not hear any ring. Number unobtainable tone or Equipment busy tone: The Number unobtainable tone may be sent to the calling subscriber due to a number of reasons. The called subscriber line may be out of order or disconnected, or there may be an error in dialing. It may also be due to congestion between the called exchange and the calling line. Routing tone or Call-in-progress tone: The Routing tone or Call-in-progress tone is heard when the call is routed through a number of different types of exchanges.
Signaling Techniques The telecommunication network classifies signaling techniques on the basis of the following:
Type of signaling information
Local loop signaling: Local loop signaling refers to signaling in which signals are transmitted between telephone equipment and the exchange. For example, the Off-hook, On-hook, Seize, and Clear signals are transmitted over the local loop. Selection signaling: Selection signaling conveys information relating to the routing of the call. Subscriber signaling: Subscriber loop signaling depends on the type of telephone instrument used, such as rotary dial telephone or a dual tone multi-frequency telephone.
Inter-exchange signaling: This type of signaling is internal to the switching system. It depends on the type and design of the switching system. Physical path used to transmit signaling information
Channel associated signaling: Signaling information is transmitted in the same path (channel) where speech signals are transmitted. In the case of SPC (Stored Program Control) exchanges, transmission of signals is in the same path, but control is independent in the exchange. Common channel signaling: In Common Channel signaling, the physical tie between the signaling path and the traffic circuit is removed. All signaling transfer, related to a transmission link, takes place over a dedicated signaling channel. Hence, a common-signaling channel handles the transfer of signaling information for numerous traffic circuits.
Technology
Loop disconnect signaling Voice frequency signaling Multi-frequency signaling Common channel signaling
Introduction Networks
Accurate network organization is very essential for call processing and routing. To have a wellorganized network, you need to plan the network carefully. Over the years, network planning has kept varying with respect to the number of subscribers. In the beginning, there were individual exchanges that connected limited subscribers in a specific area. Later, the neighboring areas were connected to these exchanges. With increasing subscribers, all the exchanges needed to be networked. Structure of the Telephone Network Initially, all exchanges were connected to each other directly. However, the network was later modified to create a system of different levels. It was no longer necessary for every exchange to be connected to every other exchange directly. The levels in a telephone network are:
The Local exchange: The subscriber lines are connected to the local exchange. The Tandem switch: The Tandem switch is used basically for the routing operation. As an exception, subscriber lines may be connected to this exchange. The Trunk exchange: Long distance calls, which need the use of trunks, go through this exchange. The International gateway: This is the highest level of exchanges. International calls are routed through this exchange.
Subscriber Line Networks The Subscriber Line Network is the network that connects the subscriber to a local exchange. The local exchange has to be able to handle situations including new subscribers from the newly constructed residential layouts, and subscribers moving from one place to another. Therefore, the subscriber line network needs to be very dynamic. The subscriber line network accounts for about 50 percent of the whole investment cost of the telephone network. Your telephone must have a permanent connection to the local exchange. Having a wire on a pole and a return via the earth does this. But when the number of telephones increases, the provision for the poles and their associated wires becomes expensive. The hunt for reduced costs and smaller wires has led to the usage of paired cables. (10, 50,100 or more pairs per cable). The evolution of subscriber line network began with the concept of Two-wire or twisted pair cables. Then came the Distribution point. The Distribution point (DP) is the point from which the cables from the exchange are connected to your telephone. Then, direct lines from the subscribers telephones are taken.
The invention of the Cross connection point or MDF (Main Distribution Frame) followed the Distribution Point. At the Cross connection point, we can have more number of incoming subscriber lines as compared to the number of lines connecting to the exchange. For example, we can have 30 pairs terminating at the cross connection point, and only 20 going out. As the probability of all lines being busy is low, we can have this degree of concentration.
Adding subscribers to the Subscriber Line Network
If subscribers are to be added to the existing subscriber network, the following techniques are used:
Cable laying: You can add subscribers to the network simply by laying more cables between the cross connection points or MDFs and the exchange. Concentrator: Concentrators or line concentrators that consolidate subscriber loops are remotely operated and the concentration or expansion portion of the switch is placed at a remote location. Concentration can also be effectively carried out using carrier techniques, either pulse-code modulation (PCM) or frequency division multiplexing (FDM). As all subscribers will not be accessing the exchange resources simultaneously, they can be connected through a line concentrator. Remote Survivable unit: Remote Survivable Unit (RSU) is a part of the main exchange located away from the parent exchange. It caters to the subscribers just like the parent exchange caters to them, and can also work as a standalone exchange with local loops. The RSU is set up to share the load of the parent exchange. Initialization, administration, operation, and maintenance are done from the parent exchange.
Make Tele-traffic measurements Provide well-defined units Calculate relation between quality of service and system capacity
In Tele-traffic theory, certain probability distributions are derived. These are designed as mathematical models. The models are usually based on mathematical relation between three factors:
Traffic Intensity
The international unit of traffic is the Erlang, named after Danish mathematician Agner Krarup Erlang, who laid the foundation of the traffic theory. An Erlang is expressed as l/m where l is the average calls arrival rate and m is the average call service rate. From a practical standpoint, the Erlang is a measure of traffic intensity, where one Erlang represents one circuit occupied for one hour. Traffic intensity can be defined in three ways:
The ratio between the period of time a switching device is occupied to the total period of time For example, if a trunk circuit is engaged on different calls for a total time of 25 minutes in an hour, the traffic intensity is determined as 0.4 Erlangs. The number of simultaneously occupied devices in a group of switching devices For example, five trunk circuits in a route are engaged at any given time. The traffic intensity is thus 5 Erlangs. The product of the number of calls per time unit and the mean holding time of calls (A = y * s) For example, in a local exchange, the total number of calls during 1 hour was 1800. The average holding time was 3 minutes. Therefore, the traffic intensity will be calculated as 1800 * 3/60 = 90 Erlangs.
Traffic Concepts There are three additional traffic concepts that affect the traffic intensity.
Traffic carried/traffic volume: The total traffic carried during a certain time is called traffic volume. Mathematically, traffic volume is an integral part of the traffic curve. Traffic offered: The concept of traffic offered is a theoretical quantity calculated on the basis of the number of circuits that are used. It is the estimated potential of the network. Traffic lost: The traffic lost is also a theoretical quantity calculated from the difference between traffic offered and traffic carried.
Traffic Volume The traffic volume keeps fluctuating during the day. Traffic volume is dependent on the subscribers habit of using telephones. When dimensioning a network, you must consider the following factors:
Traffic Metering Modern exchange equipment normally includes functions for traffic metering. These make it possible to collect data on the traffic in the exchange and store it on tapes for subsequent processing. It is also possible to collect data from many different exchanges in special operation centers. The measurements may be taken at set various factors concerning a network, such as call rate. You need to think about the media through which all the information travels and make a cost/benefit analysis of various media. Formulae used in Traffic Engineering There are two main formulae used in traffic engineering: Erlang B and Poisson. The Erlang B formula assumes that all blocked calls are cleared. This means that the subscribers do not redial when they cannot get through. The Poisson formula assumes that the subscriber simply keeps on redialing. If the Poisson method is used, you will buy more trunks than if you use Erlang B. Poisson typically overestimates the number of trunks you will need while Erlang B underestimates the number of trunks that you will need. There are other more complex but more accurate ways of estimating the number of trunks needed. Erlang C and computer simulation can be used for this.
Introduction Transmission
You need to design a transmission system for quality transmission and efficiency of operation. Once factors such as network and charging are determined, you need to determine the media through which information will travel. Transmission systems include Transmission techniques and Transmission media.
A single conversation does not utilize bandwidth to the maximum extent. To utilize the bandwidth to the full extent, you can combine many such conversations to transmit through a same line by the process of Multiplexing. The process of conveying a number of signals simultaneously over a single bearer is termed as multiplexing. FDM systems can be used on different types of media such as symmetrical paired cables, coaxial cables, radio links, and satellite links. Multiplexing can be done by two techniques:
Digital Time division multiplexing (TDM) Multiplexing in a Frequency Division Multiplexing (FDM) system: FDM systems can be used on different types of media including symmetrical paired cables, coaxial cables, radio links, and satellite links. A carrier frequency is modulated by the signal from a speech channel. The result is a number of frequency bands. Only one of these frequency bands is needed. The others are filtered out. Not even the carrier wave needs to be transmitted. It can be retrieved in the receiver as long as the frequency and phase are exactly correct. FDM was frequently used in the past, but now has been replaced with the digital equivalent Time Division Multiplexing (TDM). Multiplexing in a TDM system: In networks where high capacity is needed, it is more economical to group a number of PCM systems using higher-order multiplexing. This is done by bit interleaving. The bit rates at different multiplexing levels in a 30/32 channel system are shown below:
The idea is to combine n input signals (from each of the n channels) into a single multiplexed channel. The n individual signals are separated and processed at the distant end and fed to the appropriate output channels. A time-division-multiplexed system has a common highway shared by a number of channels, each of which occupies the highway during periodic slices of time, known as time slots (TS). This multiplexing technique requires that sampling be done to the input signal first. A number of such time slots are then combined to form a frame. Each of these time slots carries information from the corresponding channel.
Transmission Media A suitable medium is required to transmit speech signals regardless of the technique you use. Transmission media can be differentiated into two main groups:
Introduction Call Charging The set up and operation of a telecommunication network involves high investment. The capital investment includes land, buildings, switching systems, and cables. The operational cost includes salaries of staff, and costs incurred in the maintenance of the network. The
telecommunication service receives its income from its subscribers. It is therefore necessary to design a suitable charging plan to recover the costs from subscribers. Charging Plan The charging plan should be designed according to a pre-defined policy. If telephone services are considered a social right and are to be made available completely free, no charging plan is needed at all. However, as soon as you decide to take some payment, a charging plan is needed. Before you design the charging plan, you should have a policy that answers the following questions:
What portion of the costs should the subscriber pay? Should charging rates depend on the category of the subscriber? Should the rates vary with geographic location? Should the company make a profit?
Initial charge for providing a network connection Rental charge Charges for individual calls
Installation charge: When the administration connects new subscribers, some initial costs are incurred such as the equipment at the exchange that has to be assigned to the subscriber, a telephone set, and the cabling. These charges are often the same for all installations and are independent of the actual cost of an installation. Subscription fee: This is a fixed cost charged to the subscriber for the maintenance of the network, and services such as providing the telephone directory. The subscription fee is usually charged on a periodic basis, such as monthly. Call charges: Call charges are generally in direct proportion to the number of calls and the duration of these calls. Call charges also vary depending on whether the call is a local call or a trunk call. Calls may be charged differently based on the time of the day the call is made. In some cases, there are no call charges for local calls. Instead, the subscription fee is significantly higher.
Types of Charging Plans There are different types of charging plans depending upon whether you decide to charge according to the number of calls, the duration of calls, or charge a fixed amount for a particular time period.
Flat rate: The simplest possible form of charging is the flat rate charge. In this charging plan, call charges are fixed for a period of time. Whether you make 5 or 25 calls a day, the charge is the same. One of the advantages of the model is to stimulate the use of existing installations. If the company decides to opt for this model, the charges for installation are usually quite high. To avoid having to lay down new cables and other costs associated with catering to new subscribers, the company may decide to charge a flat rate. Many consumers will then use the existing phones already installed at various places. Unit fee charging: Call charges depend only on the number of calls, not on other factors such as the duration of the call or the distance involved. The exchange counts each subscribers calls. Every call costs a fixed amount regardless of where the subscriber rings or how long the call lasts. The cost per call is always the same.
Time charging: Under Time charging, the call is charged based on the duration of each call. Thus, call charges depend upon the amount of time the subscriber kept the exchange busy. The greater the distance between the called and calling subscriber, the more the equipment involved, and the more the cost of the call. For example, though Mumbai-Pune is a local call, these calls are time charged at a higher rate than a normal local call within the city. Some countries have formulated different charges for different times of the day, thus making the charging entirely dependent on the time of the day.
Charging Methods
Calls are charged by using either a metering instrument connected to each subscriber line or a metering register assigned to each subscriber in case of electronic exchanges. The count in the meter or register represents the number of charging units. The subscriber is billed by multiplying the number of charging units by the charging rate. The count in the meter is incremented by sending a pulse to the meter. Charging methods may be duration dependent or duration independent. The two charging methods prevalent are:
Periodic Pulse Metering: Periodic Pulse Metering is based on periodically generated pulses from a centrally situated pulse generator. The charge for the call is proportional to its duration. Itemized Billing: For every call, the equipment at the exchange records the numbers calling and called, together with the duration, date, time, type of service, and charging rate. This information is used to charge subscribers according to the charging plan.
Process of charging calls A charging point is the exchange where a call is recorded. In principle, the charging points should be as close to the calling subscriber as possible. For local calls, the charging point is the exchange. When the call is within the same tariff zone, the call is recorded within the local exchange. When the call is going to an exchange in another tariff zone, a more refined analysis of the relevant charge has to be carried out. Hence, one exchange in the zone becomes the new
charging point. As the recording has to be sent to the local exchange, charging pulses must be sent to the local exchange.
Glossary
Analog:
An analog signal is a continuously varying electromagnetic wave that can propagate through a variety of media.
Bit interleaving:
This is a form of Time Division Multiplexing (TDM) for synchronous protocols such as HDLC. Bit interleaving retains the sequence and number of bits to achieve correct synchronization between both ends.
Called subscriber:
In a telephone conversation, the person who receives the call is known as the called subscriber.
Calling subscriber:
In a telephone conversation, the person who initiates the call is known as the calling subscriber.
CCITT:
Consultative Committee on International Telegraph and Telephone. This is the principal international standards-writing body for digital telecom networks (ISDN).
Clear:
The clear signal is sent to the exchange after the subscriber hangs up.
Digital:
The conversion of voice or data into a stream of binary information (0s and 1s).
DTMF (Dual Tone Multi-Frequency):
A term used for push button or touchtone (an AT&T trademark) dialing. The pushed button generates a tone, actually the combination of two tones, one of high and the other of low frequency. They are necessary to access advanced network features such as call barring and call forwarding.
Hop distance:
A technique that allows many signals to be sent along the same transmission path.
Numbering Area:
The area where two subscribers use identical dialing procedure to reach any other subscriber in the network.
Off-Hook:
A telephone set in use the handset is removed from its cradle, thus sending an electric signal to the exchange that a circuit needs to be opened.
On-Hook:
The normal state of the telephone in which the handset rests on the cradle and the circuit to the exchange conducts no electric signal.
Quantum Values:
Discrete finite digital values corresponding to the specific instance of analog signal.
Seize:
The seize signal is sent to the subscriber while the exchange is checking for resources required for call setup.
Signal:
Signaling is the transmission of information by means other than the unaided human voice. Signals, which can be visual, audible, or electric, can be made by a variety of means, including lighted torches, smoke, flags, lamps, drums, guns, telegraph, telephone, and radio. Signals are used to control railroad trains and vehicular traffic on roads and highways and to communicate with ships, airplanes, and other vehicles. Transmission of electric signals over great distances is known as telecommunication.
Switching System:
A switching system is used to establish a path between a set of input and output circuits.
Tele-traffic Theory:
It is a branch of applied probability. The Tele-traffic theory is the mathematical description of message flow in a communications network.
Trunk:
It is a technology that allows your mobile phone to browse the Web. It is a protocol for data transmission over low bandwidth wireless networks.
PL/I
INTRODUCTION
PL/I was developed by IBM in the mid 1960s and was originally named as NPL(New Programming Language) It was first introduced in 1964. The name was changed to PL/I to avoid confusion of NPL with National Physical Laboratory inEngland. Previous languages had focussed on one particular area of application, such as Science or Business. PL/I was not designed as to be used in the same way. It was the first large scale attempt to design a language that could be used in a variety of application areas. PL/I is used significantly in both Business and Science applications. Marathon Oil Company, Ford Motor Company, General Motors are some of the clients. Unlike many other languages PL/I is completely free-form. No reserved keywords I.e PL/I determines the meaning of the keywords from the context of usage. E.g. : It is perfectly valid to declare a variable AREA even though it is also a PL/I keyword.
:-
:-
The first character of a label should always be an alphabet and the label should be followed by a colon. Last statement of a procedure always ends with END. END ends the program and passes the control to the operating system.
:-
DECLARE Statement
DCL is the statement after proc which means DECLARE and is used to reserve storage for data or variables indicating the attributes of a variable. In PL/1 there are 2 basic data types :1. Arithmetic data and 2. String data (char strings)
DCL Decimal data type e.g. :102.30 125.3E5 Decimal Fixed Point Decimal Floating Point
A floating point number consists of 2 parts fraction and exponent. e.g. :- 168325E20 = 168325 * (10**20)
BIT strings
Bit strings are like char strings except that the digits represent one bit (0 and 1). Bit strings must be enclosed in quotation marks. Bit strings may too have varying attributes.
e.g.
e.g.
e.g.
:-
DCL idcode CHAR(8); DCL area CHAR(3) DEF idcode; idcode=A02B1506; PUT LIST(area);
Base variable idcode occupies 8 bytes of storage. Variable area defined over it starts at the same address but it is only 3 bytes long. Put writes out the first 3 characters of idcode A02.
e.g
:-
DCL idcode CHAR(8), part1 CHAR(3) DEF idcode, part2 CHAR(3) DEF idcode POS(4), part3 CHAR(2) DEF idcode POS(7);
part1 overlays the first 3 characters of idcode; part2 is over characters 4,5,6; and part3 is over characters 7,8.
e.g
:-
e.g
:-
DCL
in storage, the number look like +123.45 To edit character strings, you may use 3 edit characters :-
1:2:3:-
X A 9
Position may hold any character. Position may hold alphabetic character or a blank. Indicates that position may hold numeric characters or space.
e.g
:-
DCL
e.g
:-
DCL switch BIT 1 INIT(1B); DCL whole FIXED DEC(5) INIT(0); DCL title CHAR(13) INIT(Weekly News);
bit string decimal floating point number character string binary fixed point number decimal fixed point number
Expressions
IF, THEN , ELSE statement
Simplest if then else statement :-
form :-
IF expression
THEN ELSE
then-unit-expression; else-unit-expression;
e.g. :-
if A <= B
then else
A=B; A=B+100;
e.g. :-
DCL
if a > b
c = 100;
c = z + 10; x = y; end;
If character strings of different lengths are compared then the shorter one is padded on the right with blank spaces. In case of bit strings; if length differs, the shorter string is padded to the right with 0B. NULL statement :- null statement consists of a semicolon. it is used where logically no statement is necessary. e.g. :-
if x > y
then
if m = n
then; else z = 0;
else
z = z + 1;
OPERATORS
comparison operators are as follows :-
not less than not greater than not equal to greater than or equal to
NOT AND OR
alt-170 & |
Concatenation character is ||
DO groups
Iterative do group used in an IF statement is also used to put several PL/1 statements together, but in this type of do group these statements are as a rule executed several times over a group. e.g. :-
do
i = 1 to 10; .. ..
end;
The do group will run through 10 times.
BY statement:If the control variable is to be increased by a step other than 1, then you use by statement. e.g. :- do count = 1 to 20 by 2; in do groups you can also count downwards. e.g. :- do i = 25 to 1 by -1; in addition to constants; variables and expressions can also be written in specification. e.g. :- do alpha = x to beta * 2 by delta;
Multiple Specification :multiple specifications can be used in a do statement. control passes to the next specification when previous has finished. e.g. :- do i = 1 to 5, 20 to 25, 50; This loop is executed 5 times for i = 1 to 5, then 6 times for i = 20 to 25, and then again with i = 50. Hence the loop is executed totally 12 times. Often do groups have to be executed until a certain condition is met. these cases can be handled with while statement.
e.g. :- do while (x < y); This loop is executed as long as x is less than y. e.g. :-
do while endo;
This loop runs as long as x > y and z is not equal to 100.
Nested DO groups :Nesting of do groups to a maximum of 49 is allowed by PL/1 optimizing compiler. e.g. :-
outer :
do i = inner :
1 to 5; do j = 1 to 3; ..
end end
e.g. :- To leave an iterative do group.
inner;
outer;
do
end;
GOTO statement
With goto statement you can jump to any statement, which has a label, except an iterative do group. e.g. :-
i = i + 1; goto a; b:
do
i = 1 to 5; numbers(i) = i * 2;
end;
Subscripts need not just consist of constants and variables, they can also be whole expressions. e.g. :cost(i+j) numbers(i+2) numbers(costs(i)) costs(i+j*2)
Built-in functions :A built-in function replaces a number of statements which the programmer would otherwise have to write himself. For e.g. function ALWAYS return one value and is recognised by PL/1 thru syntax. e.g. :dcl (a,b) fixed dec(9); dcl x(10) fixed dec(3);
Multi-Dimensional Array :The dimension attribute states the number of the dimensions for an array and the bounds of each dimension. e.g. :- dcl table(7,2) fixed decimal(3); The above mentioned array consists of 7 rows and 2 columns. e.g. :- dcl parts(3,3,5) char(10); The above declared parts array consist of 45 elements. e.g. :dcl tab(3,5) fixed binary(15);
do
j = 1 to 3; do k = 1 to 5; tab(j,k) = 2; end;
end;
x = sum(tab); Value of x after execution is 30 because each of the 15 elements in this array is set to 2. All element of array tab can be set to 2 by one single instruction. [ tab = 2 ].
Cross section of an array :you can also address a cross section of a array. e.g. :dcl figures(5,3) fixed dec; dcl x(3); x = figures(2,*); in the above case * represents all the elements of row 2. hence x = figures(2,*) is equal to x(1) = figures(2,1); x(2) = figures(2,2); x(3) = figures(2,3);
dcl 1
Name of the whole structure is personnel. Each element in it, has its own name and its own attribute. During processing elements can be addressed singly or all together using the structure name. A single element can be addressed by its name.
for e.g. :name = Siva Mani; put file(out) list(personnel); put file(out) list(name, salary); The above two statements have the same meaning. write to the file out the values of name and salary. Maximum number of levels in a structure is 15.
dcl
There are 12 occurence of month and each occurence has 2 elements. If you want to refer the element min in 10th structure. month(10).min (OR) month.min(10) Qualified name is month(10).min (OR) month.min(10)
2 2 1
There is an assignment for all the elements which have the same qualified names in the structures new and old. new = old, by name; 3 elements are assigned in this structure expression. new.name = old.name; new.payment.gross = old.payment.gross; new.payment.net = old.payment.net;
Introduction to Input/Output
Basic features of Input/Output
GET :Transmits or gets data from external medium to internal storage.
PUT :Transmits data from internal to external storage. 2 types of transmission are there between internal & external storage :stream i/o with get & put :Data item is transmitted singly. advisable for small quantities i.e. screen & card readers. record input/output with read & write :Complete record of data items is transmitted and copy of the record is usually kept in internal storage. It is preferable for larger qty of data.
e.g. :-
dcl master file record sequential; . open file(master) output; . close file(master);
Environment attribute
Environment attribute defines the physical organisation of data sets (e.g. record length, blocks) and the method of processing them. Default value for the type of organization is consecutive. this type of organization can be processed only sequentially.
e.g. :-
Record is an attribute in the declaration. Stream is default for the transmission type.
STREAM Input/Output
STREAM I/O Features
A string of characters is transmitted in stream i/o. Character data type will not cause conversion if it is used in get or put.
the get and the put statements not having data file declarations are linked with standard files for which there are prescribed file names. SYSIN for input, SYSPRINT for output
hence is taken as
3 Types of I/O Stream list data edit List-Directed I/O :It is simplest form of stream I/O, and is ideal for testing input at the terminal.
always requires data list requires no list requires data and format list
e.g. :-
e.g. :-
14 elements would be read by the get statement. Input in list directed i/o is in character form. The data items are separated by comma and/or blanks.
Data-Directed I/O :Input data can be read in the form of assignment statements in input stream. a semi colon or the end of data file ends the transmission of an i/o statement.
e.g. :-
in first read A is numerical and B is character. on second get A = 5 and B is unchanged. on third get A is unchanged and B is UV.
Edit-Directed I/O :-
It is the most commonly used type of stream i/o. a data list is needed here as well, to contain the names of data items, arrays or structures. in addition a format list is required in which the format of i/o data is described.
e.g. :-
put file(output) edit(data list) (format); get file(sysin) edit(data list) (format);
e.g:get edit(qty, price, text) (f(3),x(6),f(5,2),x(5),a(10)); F is used for numeric data item, A for character string, X for space.
ON ERROR condition
PUT statements without data list, write out all the variables of a program block. they give programmers an excellent tool to use in searching for tools.
e.g. :-
on error
The on error condition must also have been run thru atleast once before it can be executed.
On error system means that in case of an error, the system routine is executed that includes breaking off the program execution.
Record Input/Output
Overview & Differences between STREAM & RECORD I/O RECORD I/O STREAM I/O Data is considered as a continuous sequence. Data conversion is possible. SYSIN and SYSPRINT are valid standard files Allows only sequential form of data set.
RECORD I/O offers 2 alternative modes of processing (move / locate). MOVE mode :- In move mode, a logical record is transmitted by reading from the buffer to an area (e.g. structure) where it is then processed. FORM :- read file(filename) into(area); using read, a logical record is put into a variable declared in the program.
e.g.:-
dcl
read file(material) into(inrec); IGNORE option :- ignore specifies how many logical records are to be skipped. form :- read file(filename) ignore(N); N is the number of records to be skipped.
Record output in MOVE mode:- On each write, a logical record is transmitted from the area to a buffer. if record (or
block) is full, a physical record (for block) is written into the data set. form :- write file(filename) from(area); write statement causes a record to be written from the area specified i.e. the records are put in blocks.
e.g. :-
dcl pers
file input sequential buffered env(consecutive FB RECSIZE(100) BLKSIZE(500) BUFFERS(3)); FB RECSIZE BLKSIZE BUFFERS means fixed record length, blocked means length of the record in bytes means length of the block in bytes means number of buffers
The record has 100 characters and block has 500 characters, hence there are 5 records per block. Environment attribute describes the physical properties of a data set. consecutive means that records are stored sequentially.
LOCATE mode
In this mode the logical records are directly processed in buffer. here a based variable or a pointer variable is needed (a structure with the length of a logical record) is like a mask which is laid over the buffer.
record input in locate mode :- Files to be processed using locate mode must, like other files be declared and
opened. the first physical record has already been read into the buffer and opened.
POINTER Variable
A pointer variable is a variable (full word, 4 bytes) which contains a storage address. this address can be assigned to pointer variable in various ways.
e.g. :-
A pointer is used to point to the position of the next record in a buffer or to another variable.
BASED Variable
In the e.g. given below, read places the address of next logical record in the pointer ptr.
env(fb recsize(200) blksize(1000) buffers(1)); dcl q pointer; dcl record_a char(200) based(q); .. read file(one) set(q);
On 6th read, the 2nd physical record is retrieved from the data set and put in buffer.
you recognize MOVE mode by the option FROM and LOCATE mode by the option SET.
Record Output in Locate mode Records read in are written out form :- LOCATE based_variable FILE(filename);
F e.g. :- dcl in file record buffered input
env(fb recsize(100) blksize(1000) buffers(2)); dcl out file record buffered output env(fb recsize(100) blksize(1000) buffers(2)); dcl inrec char(100) based(q); dcl outrec char(100) based(p);
loop : read file(in) set(q); locate outrec file(out); outrec = inrec; goto loop;
With REWRITE statement, records read in can be changed and written back to the same place they came from in the data set. F e.g. :- dcl personnel file sequential buffered update; dcl record char(500) based(p); dcl p pointer;
note :- There is 4 byte record length field (RL)before every variable record.
e.g. :- suppose the biggest logical record can be 1000 bytes long and that the records are to
be blocked in such a way that a block is likewise to have the maximum length of 1000 bytes, then environment attribute of file declaration would look like env(vb recsize(1004) blksize(1008));
recsize = 1000 bytes + 4 bytes record length blksize = recsize + 4 bytes block length
F In fixed format, the record length and the block lengthare fixed but in variable format, the record length and the block length vary
block length is size of the physical record record length is size of the logical record
If data length of the record is 750, the record sizewill be 754 and the block size will be 758.
Note :- Sequential is the default file organization, hence vsam should be specified in the ENV option.
Vsam files are always record files. Records on a vsam file are not held in blocks, hence the blksize option even if specified is ignored. A recsize option will be checked against the details stored with the file. The utility IDCAMS (access method services) is used to set up a vsam file initially.
A ksds has a key which is part of a data record, this is known as an embedded key. Keys are also stored in another part of data set called as prime index. The keys are unique since duplication is not allowed. KSDS Features Reading a ksds directly :- Records are accessed by specifying a value using the key option. e.g.:- dcl amast file record direct input env(vsam); dcl 1 area, 2 kskey char(5), 2 ksname char(15); read file(amast) into(area) key(00010);
Updating a ksds directly :- The file should be opened as update. you cannot amend the key.
e.g.: dcl kmast file record direct update env(vsam); dcl 1 area, 2 kskey char(5) init(00081), 2 ksname char(15); read file(kmast) into(area) key(kskey); /* amend */ rewrite file(kmast) from(area) key(kskey);
e.g.: dcl ramp file record sequential keyed env(vsam); read file(ramp) into(area) key(123/999/b); read file(ramp) into(area); GENKEY option F e.g. :- dcl vsam file record sequential keyed
env(vsam genkey); read file(vmast) into(area) key(123); read file(vmast) into(area); Assume that the key is defined as nine chars long. If genkey option is not specified in the environment statement, vsam searches for a record with a key of 123. If genkey option is specified the first read reads the first record of data set beginning with 123. Second read continues with the record immediately following it.
Updating an esds file :It is possible to change records once they have been written to esds file. e.g. :- read file(esds) into(area); rewrite file(esds) from(area); Write can also be used and the new records added are always added at the end. Delete is not allowed.
rba=0 rba=50
You have to get hold of rba by using KEYTO option on read and write. F e.g. :- dcl esds file record sequential keyed update env(vsam); dcl rba char(4); write file(esds) from(area) keyto(rba); Rba must be a 4 byte character string. this will add a new record to the end of the file and place the relative byte address of the record in the field rba. this is then used as a key on a read or rewrite. file should be declared as keyed. e.g. :- read file(esds) into(area) key(rba);
dcl esds file record sequential keyed update env(vsam); dcl rba char(4); read file(esds) into(area) keyto(rba); ...... rewrite file(esds) from(area) key(rba);
145);
WRITE in an RRDS
relrecno = 00000005; read file(rrds) into(area) key(relrecno); delete file(rrds) key(relrecno); write file(rrds) from(area) keyfrom(relrecno);
VERIFY (Built-in Function) VERIFY function :- Verify will see that a string will have only certain characters present. form :- verify(x, y);
X is the string of chars to be checked in Y. Y is the string containing the list of characters which are to be looked for.
A binary fixed point number is returned :- zero, if all characters in X appear also in Y. - A value, which gives the position of the first character in X which does not appear in Y. F e.g. :- dcl test char(3);
test=BIT; IX=verify(test,ABCDEDFGHI); 3 would be returned, because the third character is not in the second parameter of verify.
form :- length(x);
F e.g. :- dcl field char(90) varying; field = GOOD LUCK !; ilength = length(field);
Pseudovariables
If a function is on the left in an assignment, you have a pseudovariable. pseudovariables are functions which may not only manipulate values, but may also receive them. F e.g. :- substr(tfield,2,5) = gfield;
/* soln is ABCDEABCDE */
Program Organization
Types of Blocks F PL/1 knows two types of blocks :-
1. Procedures 2. Begin-blocks
1. External Procedures 2. Internal Procedures An EXTERNAL procedure is a block which is not contained in another block. They are compiled separately but they can joined to make one program by linkage editor, so that 2 programmers can work on it simultaneously. Option main identifies the main procedure. i.e. label:proc options(main); An INTERNAL procedure is invoked by a call from a surrounding block and control returns to statement after the call. Within an external procedure you can have upto 50 internal procedures. F e.g. :- outer:proc options(main); statement1 call inner; -> statement2 : ^ : : : : V inner:proc; <statement3 statement4 - end inner; :
BEGIN-block :- They always lie within a procedure and are executed where they are. They finish with an end statement. F form :- A:proc;
begin; end; end A;
Scope of Declaration Variables which are declared have two scope attributes :1. Internal 2. External
If a variable has an INTERNAL scope, then it is known in the block in which it was declared and in all the blocks which physically lie in that block until it is not declared in one of these subordinate blocks. e.g. :- outer:proc options(main); dcl rate fixed dec(7,3); dcl minus char(5); dcl x char(100); inner:proc; dcl minus fixed dec(7,2); dcl x char(100); end inner; end outer; rate field is addressed in both blocks. character field minus is not known in block inner. The variable X has attribute internal and hence you are dealing with 2 variables that are known within their blocks. If a variable is to be same in two external procedures, then it must be declared with same attributes EXTERNAL. mpro:proc options(main); subpro:proc; dcl 1 rec external, 2 a char(30), 2 b fixed bin(31); dcl 1 rec external, 2 a char(30), 2 b fixed bin(31);
Structure rec which is declared in both external procedures, occupies the same data area.
begin; < :
free fieldx;
Arguments
When a procedure is invoked using a call, it is possible to pass variables which are called as arguments. F e.g. :- dcl rec1 char(45);
call srou(rec1,inrec);
/* arguments */
Parameters
A program to which arguments are passed when it is invoked, are called as parameters. F e.g.:- srou:proc(a,b);
dcl a char(100);
Here a & b are the parameters where a = rec1 and b = inrec. The sequence and the attributes of the arguments and parameters must be identical. names may be different, but they use same area. Note :- null arguments may be indicated by two commas and unnecessary arguments of the end of the list may be omitted.
Functions
Functions are always a part of an expression. A function is replaced by its result after execution.
x = sum(tab3);
/* with an argument */
v = date(); F F
(ON-UNIT)
On ENDPAGE and on ENDFILE are some important conditions which can be forseen. F e.g. :- on endpage(sysprint) begin;
n = n + 1;
put edit(page, n) (page, x(70), a, pz9); put skip(3); end; This writes the current page number when the preceding page is full.
SIGNAL & REVERT SIGNAL option :-With signal statement, a condition can be caused artifically. The program continues with the statement
which comes immediately after signal statement. form :- SIGNAL condition; Signal is used to raise conditions deliberately. e.g. :- on endpage(print3) call overs; signal endpage(print3);
Sample Programs
Sample Program 1
run221a:proc options(main);
dcl alpha fixed decimal(7,0), beta fixed decimal(6,0); dcl (a,b,c) fixed decimal(5,2), answer fixed decimal(7,2);
fini:end run221a;
Sample Program 2
P1M0:proc options(main); dcl counter fixed dec(1); dcl total fixed dec(7,2);
counter=0; total=0;
read: get file(sysin) list(number); total = total + number; counter = counter + 1; goto read;
end p1m0;
Sample Program 3
P3M0:proc options(main); dcl (countin, countout) fixed dec(3) init(0); dcl (totalin, totalout) fixed dec(7,2) init (0); dcl (averagein, averageout) fixed dec(5,2); dcl number fixed dec(5,2);
read:get file(sysin) list(number); if number > 100 & number <= 60; then goto in; totalout = totalout + number; countout = countout + 1;
goto read;
in: totalin = totalin + number; countin = countin + 1; goto read; finish: averagein = totalin / countin; averageout = totalout / countout;
put file(sysprint) list(countin, totalin, averagein); put file(sysprint) skip list(countout, totalout, averageout);
end; P6M0:proc options(main); dcl temp(7,2) fixed dec(3), da(7) fixed dec(3); dcl wa fixed dec(3), i fixed bin(15), eof bit(1) init(0B);
on endfile(sysin) eof=1B;
get file(sysin) list(temp); /* seven pairs of temparature */ do while (eof = 0B); do i = 1 to 7; da(i) = (temp(i,1) + temp(i,2)) / 2; end;
put file(sysprint) skip list(da); /* write to sysprint */ put file(sysprint) skip list(wa); /* 7 values of da,wa */ get file(sysin) list(temp); end; end p6m0; /* new input of temp */
Sample Program 5
P9M0:PROC OPTIONS(MAIN);
dcl E1 file record env(F recsize(50), blksize(50)); dcl A CHAR(50) init(THIS IS A TEST); write file(E1) from(A); /* output is written to file E1 */
close file(E1);
put data(A);
end P9M0;
Sample Program 6
p11m0: proc options(main); dcl 1 indet, 2 intype char(1), 2 itemno char(5), 2 uprice fixed dec(3,2), 2 qty fixed dec(3), 2 deptno char(3), 2 code1 fixed dec(3), 2 code2 fixed dec(3), 2 code3 fixed dec(3), 2 iname char(23), 2 dname char(27); dcl ab char(40);
dcl 1 sta based(addr(ab)), 2 rectype char(4), 2 itemno char(4), 2 uprice fixed dec(3,2), 2 qty fixed dec(3), 2 totval fixed dec(7,2), 2 iname char(23);
dcl 1 stb based(addr(ab)), 2 rectype char(4), 2 deptno char(3), 2 code1 fixed dec(3), 2 code2 fixed dec(3), 2 code3 fixed dec(3), 2 dname char(27); dcl a1 file record env(fb recsize(40) blksize(400)); dcl (eofi, eofa) bit(1) init(0b); on endfile(sysin) eofi = 1b; open file(a1) output; do until (eofi = 1b); read file(sysin) into(indet); if eofi then do; if intype = A then do; sta=indet, by name; sta.rectype = fap7; sta.totval = indet.uprice * indet.qty; end; else do; stb=indet, by name; stb.rectype = fbp7; end; write file(a1) from(ab);
end; else close file(ab); on endfile(a1) eofa = 1b; open file(a1) input; do until (eofa); read file(a1) into (ab); if eofa then if sta.rectype = fap7 then put skip list(sta); else put skip list(stb); else close file(a1); end; end p11m0;
Sample Program 7
P14M0: proc options(main); dcl ca char(78); dcl (name,street,town) char(25); dcl 1 prline, 2 cc char(1) init( ), 2 text char(25); dcl (del1,del2,del3) fixed bin(15); dcl (sn,ss,st) fixed bin(15); dcl (ln,ls,lt) fixed bin(15);
do until (eof); read file(sysin) into(ca); if eof then do; del1=index(ca,,'); del2=index(substr(ca,del1+1),,') + del1; del3=index(substr(ca,del2+1),,') + del2;
Sample Program 8
P16M0:proc P16M0 */ proc options(main); dcl p16m2 entry;
dcl (number,pvalue) fixed decimal(5,2); on eof bit(1) init(0B); on endfile(sysin) eof = 1B; do until(eof); get list(number); if eof then do; call p16m2(number,pvalue); put skip list(number,pvalue); end; end; end;
P16M2:proc(number,pvalue); dcl (number,pvalue) fixed decimal(5,2); if number >= 100 then pvalue = number * 0.05; else pvalue = number * 0.03; end
Share this: