0% found this document useful (0 votes)
355 views

Shell Entrance Area Calculation-R0

This document provides calculations for the shell entrance area of a piece of equipment. It lists common parameters such as flow rate, medium density, nozzle inside diameter, and tube dimensions. It then calculates the shell entrance area based on these parameters and dimensions using appropriate formulas. The calculated shell entrance area is 0.007998 m2 and is acceptable based on the given shell entrance velocity.

Uploaded by

nagtummala
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
355 views

Shell Entrance Area Calculation-R0

This document provides calculations for the shell entrance area of a piece of equipment. It lists common parameters such as flow rate, medium density, nozzle inside diameter, and tube dimensions. It then calculates the shell entrance area based on these parameters and dimensions using appropriate formulas. The calculated shell entrance area is 0.007998 m2 and is acceptable based on the given shell entrance velocity.

Uploaded by

nagtummala
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Project : Project no : Item no : Item name : XXXXXXXXXXXXXXXXXXXX Owner ID : XXXXXXXXXXXXXXXXXXXX SHELL ENTRANCE AREA CALCULATION Common Parameters :Flow

rate as per datasheet

22557 kg/hr 6.265833 kg/s 0.006113 m3/s 1025 kg/m3 658 750 728 25.4 19.05 1 kg/ms2 mm mm mm mm

r rv2 Ds = OTL = Pt = Dt = F2 =

Medium Density as per datasheet Shell entrance rv2 as per datasheet Shell inside diameter, mm Outer Tube limit diameter, mm Tube center to center pitch, mm. Tube ouside diameter, mm Factor indicating tube pitch type F2 = 1.0 for 900 and 300 type F2 = 0.866 for 600 F2 = 0.707 for 450

SHELL ENTRANCE AREA CALCULATION :

4.6211 (select from 4.6211, 4.6212, 4.6221, 4.6222) Dn = Nozzle inside diameter, mm. 146.36 mm F1 = Factor indicating presence of impingement plate 0
Shell Entance arrangement Type RGP-RCPF1 = 0 with impingement plate F1 = 1 without impingement plate h= Average free height above tube bundle or impegment plate, mm. h = 0.5*(h1+h2) for Figures RGP-RCP-4.6211,4.6212,4.6222 h = 0.5*(Ds - OTL) for Figures RGP-RCP-4.6221 Maximum free height (at centerline), mm (measured from drawing) Minimum free height (at nozzle edge), mm h2 = h1-(0.5*(Ds- (Ds^2 - Dn^2)^0.5)) *Dn*h + (F1*(/4*Dn2)*((Pt-Dt)/(F2*Pt))

17.4 mm 17.4 11.0 21 mm 13.8


7998 mm2 0.007998 m2 1 m/s 599

h1 = h2 =

Shell Entance area As =

Shell Entrance Velocity rv2 as per geometry Shell Entrance area is acceptable