Shell Entrance Area Calculation-R0
Shell Entrance Area Calculation-R0
22557 kg/hr 6.265833 kg/s 0.006113 m3/s 1025 kg/m3 658 750 728 25.4 19.05 1 kg/ms2 mm mm mm mm
r rv2 Ds = OTL = Pt = Dt = F2 =
Medium Density as per datasheet Shell entrance rv2 as per datasheet Shell inside diameter, mm Outer Tube limit diameter, mm Tube center to center pitch, mm. Tube ouside diameter, mm Factor indicating tube pitch type F2 = 1.0 for 900 and 300 type F2 = 0.866 for 600 F2 = 0.707 for 450
4.6211 (select from 4.6211, 4.6212, 4.6221, 4.6222) Dn = Nozzle inside diameter, mm. 146.36 mm F1 = Factor indicating presence of impingement plate 0
Shell Entance arrangement Type RGP-RCPF1 = 0 with impingement plate F1 = 1 without impingement plate h= Average free height above tube bundle or impegment plate, mm. h = 0.5*(h1+h2) for Figures RGP-RCP-4.6211,4.6212,4.6222 h = 0.5*(Ds - OTL) for Figures RGP-RCP-4.6221 Maximum free height (at centerline), mm (measured from drawing) Minimum free height (at nozzle edge), mm h2 = h1-(0.5*(Ds- (Ds^2 - Dn^2)^0.5)) *Dn*h + (F1*(/4*Dn2)*((Pt-Dt)/(F2*Pt))
h1 = h2 =
Shell Entrance Velocity rv2 as per geometry Shell Entrance area is acceptable