0% found this document useful (0 votes)
111 views4 pages

Haz Area Classification

This document lists Indian and IEC codes for hazardous areas as of May 10, 2008. It includes over 50 codes covering topics like flameproof enclosures, increased safety, intrinsic safety, pressurized enclosures, powder filling, and oil immersion. For each code, it provides the standard number, title, and status (e.g. latest version, under printing, to be adopted). The codes listed are for electrical apparatus intended for use in explosive gas atmospheres and combustible dusts.

Uploaded by

amit_lunia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views4 pages

Haz Area Classification

This document lists Indian and IEC codes for hazardous areas as of May 10, 2008. It includes over 50 codes covering topics like flameproof enclosures, increased safety, intrinsic safety, pressurized enclosures, powder filling, and oil immersion. For each code, it provides the standard number, title, and status (e.g. latest version, under printing, to be adopted). The codes listed are for electrical apparatus intended for use in explosive gas atmospheres and combustible dusts.

Uploaded by

amit_lunia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ANNEXURE A

LIST OF INDIAN & IEC CODES FOR HAZARDOUS AREA AS ON 10 May 2008
IS CODE NO TITLE OF INDIAN STANDARD
IS/IEC 60079-0 2004 IS/IEC60079-1 2007 IS 9735-2003/ IEC60079-1-1: 2002

IEC CODE NO TITLE OF IEC STANDARD


IEC 60079-0 Ed 5 2007/10 IEC 60079-1 Ed6 2007/04 IEC 60079-1-1 2002/07 IEC 60079-2 Ed5 2007/02 IEC/TR 60079-13 1982/01 IEC/TR 60079-16 Ed11990/05 IEC 60079-7 Ed4 2006/07 IEC 60079-11 2006/07 IEC 60079-25 2003/8 IEC 60079-26 Ed2 2006/08 IEC 60079-27 Ed2 2008/01

STATUS
Latest Version Under Printing Latest Version Printed as IS Latest Version Printed as IS Latest Version Under Printing Latest Version Printed as IS Latest Version Printed as IS Latest Version Under Printing Latest Version Under Printing Latest Version Printed as IS To be adopted To be adopted To be adopted Latest Version Under Printing

Electrical apparatus for explosive gas atmospheres General Requirements Explosive atmospheres Part1-Euipment Protection by Flameproof Enclosures "d" Electrical Apparatus for explosive gas atmospheres Flameproof enclosures 'd'-Method of test for ascertainment of maximum experimental safe gap (First Revision)

Explosive atmospheres Part 0 : Equipments-General Requirements Explosive atmospheres Part1-Euipment Protection by Flameproof Enclosures "d" Electrical Apparatus for explosive gas atmospheres Part 1-1: Flameproof enclosures 'd'-Method of test for ascertainment of maximum experimental safe gap Explosive atmospheres Part 2: Equipment Protection by Pressurised enclosures 'p' Electrical Apparatus for explosive gas atmospheres Part 13:Construction and use of rooms or buildings protected by pressurisation Electrical Apparatus for explosive gas atmospheres Part 16:Artificial Ventilation for the protection of analyser houses Electrical Apparatus for explosive gas atmospheres Part 7 : Incresed Safety 'e' Electrical Apparatus for explosive gas atmospheres Part 11: Intrinsic Safety 'i'

Electrical Apparatus for explosive gas atmospheres IS 7389:2004/ IEC60079-2:2001 Pressurised enclosures 'p' (First Revision) Guide for construction & use of rooms or buildings protected by pressurisation for installation of electrical apparatus for explosive gas atmoshpheres Electrical Apparatus for explosive gas atmospheres Part IS/IEC 60079-16 16:Artificial Ventilation for the protection of analyser 2004 houses
IS 11064:1984

Electrical Apparatus for explosive gas atmospheres IS 6381-2004/ IEC60079-7:2001 Incresed Safety 'e' Electrical Apparatus for explosive gas atmospheres IS 5780:2002/ IEC60079-11: 1999 Intrinsic Safety 'i' : Specification
IS/IEC 60079-25 2003

Electrical Apparatus for explosive gas atmospheres Part 25: Intrinsically Safe Systems

Electrical Apparatus for explosive gas atmospheres Part 25: Intrinsically Safe Systems Explosive atmospheres Part 26: Equipment with Equipment Protection Level (EPL) Ga Explosive atmospheres Part 27: Fieldbus intrinsically safe concept (FISCO) Explosive atmospheres Part 28: Protection of IEC 60079-28 Ed1 Equipments & transmission system using optical 2006/08 radiation
IEC 60079-5 Ed3 2007/03

Sand filled electrical apparatus for use in explosive IS 7724-2004/ IEC60079-5:1997 atmoshpheres

Explosive Atmospheres Part 5: Equipment Protection by Powder filling 'q'

Annex A updated May 08 Page 1

ANNEXURE A

LIST OF INDIAN & IEC CODES FOR HAZARDOUS AREA AS ON 10 May 2008
IS CODE NO TITLE OF INDIAN STANDARD
Electrical Apparatus for explosive gas atmospheres - Oil IS 7693-2004/ IEC60079-6:1995 immersion 'o'
IS/IEC 60079-15 2005 IEC 60079-18 2004 IS 5572-1994

IEC CODE NO TITLE OF IEC STANDARD


IEC 60079-6 Ed3 2007/03

STATUS
Latest Version Under Printing Latest Version Printed as IS Latest Version Printed as IS Under Adoption

Explosive atmospheres Part 6: Equipment Protection by Oil immersion 'o'

IS 9570-1980

IS 5571-2000

IS 13408(Part1) 1992

Electrical Apparatus for explosive gas atmospheres Part Electrical Apparatus for explosive gas atmospheres Part IEC 60079-15 Ed3 15: Construction, Test & Marking of Type of protection 15: Construction, Test & Marking of Type of protection 'n' 2005/03 'n' Electrical Apparatus Electrical Apparatus Electrical Apparatus for explosive gas atmospheres Part Electrical Apparatus for explosive gas atmospheres Part IEC 60079-18 Ed2 18: Construction, Test & Marking of Type of protection 18: Construction, Test & Marking of Type of protection 2004/03 'm' Electrical Apparatus 'm' Electrical Apparatus Classification of hazardous areas (other than mines) IEC 60079-10 Ed4 Electrical Apparatus for explosive gas atmospheres Part having flammable gases & vapours for electrical 2002/06 10: Classification of hazardous area installation Electrical Apparatus for explosive gas atmospheres Part Classification of flammable gases & vapours with air IEC/TR 60079-12 12:Classification of mixures of vapours with air according according to their maximum experimental safe gaps Ed1 1978/01 to their maximum experimental safe gaps and minimum and minimum igniting currents igniting currents Electrical Apparatus for explosive gas atmospheres Part IEC/TR 60079-20 20: Data for flammable gases & vapours relating to use Ed1 1996/10 of electrical apparatus Explosive Atmospheres (Other than mines & explosives) Guide for selection of electrical equipment for IEC 60079-14 Ed4 Part 14: Electrical installations -Design, Selection & 2007/12 hazardous area (Second Revision) Erection Code of practice for the selection, installation & maintenance of electrical apparatus for use in Explosive Atmospheres (Other than mines & explosives) IEC 60079-17 Ed4 Part 17: Electrical Installations - Inspection & potentially explosive atmoshpheres (other than mining 2002/07 application or explosive processing manufacture) Part Maintenance 1: General recommendation
IEC 60079-19 Ed2 Explosive atmospheres (Other than mines & explosives) 2006/10 Part 19: Equipment Repair, overhaul & reclamation

Latest Version Printed as IS

Under Adoption

Under Adoption

Latest Version Under Printing

Latest Version Under Printing Latest Version Printed as IS

Electrical Apparatus for explosive gas atmospheres : IS 7820:2004/ IEC60079-4:1975 Method of test for ignition temperature

IEC 60079-4 1995/07

Electrical Apparatus for explosive gas atmospheres Part 4: Method of test for ignition temperature

Annex A updated May 08 Page 2

ANNEXURE A

LIST OF INDIAN & IEC CODES FOR HAZARDOUS AREA AS ON 10 May 2008
IS CODE NO TITLE OF INDIAN STANDARD
IS 5679-1986

IEC CODE NO TITLE OF IEC STANDARD


Caplights for use in mines susceptible to firedamp Part IEC 62013-1 Ed 2 1: General requirement- Construction & testing in relation 2005/10 to risk of explosion IEC 62013-2 Ed 2 Caplights for use in mines susceptible to firedamp Part 2005/10 2: Performance & other safety related matters

STATUS
Latest Version Under Printing Latest Version Under Printing Under Revision Under Revision

Miners Cap lamp assemblies (incorporating lead acid type batteries)

IS 9836-1981 IS 9959-1980 IS 4051-1967

Exploders Guide for selection of electrical & electronic equipment for coal mines Code of Practice for installation & maintenance of electrical equipment in mines
IEC60079-29-1 Ed1 Performance requirements of detectors for flammable 2007/08

Explosive Atmospheres Part 29-1: Gas Detectors-

Under Adoption gases Explosive Atmospheres Part 29-2: Gas DetectorsIEC60079-29-2 Ed1 Selection, installation, use and maintenance of detectors Under Adoption 2007/08 for flammable gases and oxygen
IS 14774(Part 1) - Resistance trace heating in potentially explosive 2000 atmoshpheres Part 1 General & testing requirements IS 14774(Part 2) atmoshpheres Part 2 Informative application guide for 2000 IEC60079-30-1 Ed1 Explosive atmospheres Part 30-1: Electrical resistance 2007/01 trace heating- General & testing requirements IEC60079-30-2 Ed1 trace heating- Application guide for design, installation & 2007/01

To be adopted

Resistance trace heating in potentially explosive

Explosive atmospheres Part 30-2: Electrical resistance maintenance

To be adopted To be scrapped To be scrapped

design, installation and maintenance Dust tight ignition proof enclosures of electrical IS 11005-1984 equipment Electrical apparatus with protection by enclosure for use IS 14154(Part1) in the presence of combustible dusts: Part 1 1996 Specification for apparatus

IEC 61241-0 Ed1 2004/7 IEC 61241-1 Ed1 2004/05

Electrical apparatus for use in the presence of combustible dust: Part 0: General Requirements Electrical apparatus for use in the presence of combustible dusts: Part 1:Protection by enclosures 'tD'

Under Adoption Under Adoption

Annex A updated May 08 Page 3

ANNEXURE A

LIST OF INDIAN & IEC CODES FOR HAZARDOUS AREA AS ON 10 May 2008
IS CODE NO TITLE OF INDIAN STANDARD
IS 12315(Part 1) temperature of dusts Part 1: Dust layer on a heated 1988

IEC CODE NO TITLE OF IEC STANDARD


IEC 61241-2-1 Ed1 1994/12

STATUS
Under Adoption

Method of determining the minimum ignition surface at a constant temperature

IEC/ TS 61241-2-2 Ed1 1993/08

IS 12315(Part 2) temperature of dusts Part 2: Dust cloud in a furnace at 1988

Method of determining the minimum ignition a constant temperature

IEC 61241-2-3 Ed1 1994/09 IEC 61241-4 Ed1 2001/03 IEC 61241-10 Ed1 2004/06 IEC 61241-11 Ed1 2005/10

Electrical apparatus for use in the presence of combustible dusts: Part 2: Test methods- Section 1: Method of determining the minimum ignition temperature of dust Electrical apparatus for use in the presence of combustible dusts: Part 2: Test methods- Section 2: Method of determining the electrical resistivity of dust in layers Electrical apparatus for use in the presence of combustible dusts: Part 2: Test methods- Section 3: Method of determining the minimum ignition energy of dust / air mixture Electrical apparatus for use in the presence of combustible dusts: Part 4: Type of protection 'pD' Electrical apparatus for use in the presence of combustible dusts: Part 10: Classification of areas where combustble dusts are or may be present Electrical apparatus for use in the presence of combustible dusts: Part 11:Protection by intrisic safety 'iD'

Under Adoption

Under Adoption

Under Adoption Under Adoption

Under Adoption

IS 15142:2002 IS 14154(Part2) 1997

Guide to the use of Electrical Apparatus for potentially explosive atmospheres in the presence of combustible dust Electrical apparatus with protection by enclosure for use IEC 61241-14 Ed1 Electrical apparatus for use in the presence of in the presence of combustible dusts: Part 2 Guide 2004/07 combustible dusts: Part 14: Selection & Installation to selection, installation & maintenance Electrical apparatus for use in the presence of IEC 61241-17 Ed1 combustible dusts: Part 17:Inspection & maintenance of 2005/01 electrical installations in hazardous areas (Other than mines) Electrical apparatus for use in the presence of IEC 61241-18 Ed1 combustible dusts: Part 18: Protection by encapsulation 2004/08 'mD'
Email [email protected] / [email protected]

To be scrapped

Under Adoption

Under Adoption

Under Adoption

Annex A updated May 08 Page 4

You might also like