0% found this document useful (0 votes)
131 views2 pages

Corrugated Hanger Specifications Guide

This document provides specifications for corrugated hangers used to connect wood joists. It includes: - Dimensions and material properties for 16 different hanger models with width ranging from 40-120mm. - Details on allowable fastener configurations (nails or screws) and their characteristic strength values for uniaxial and biaxial loading conditions. - Certification information confirming the hangers meet the requirements of EN 1995 and have an ETA-08/0264 CE marking. The hangers are made from S250 GD + Z275 steel with a thickness of 2.5mm. Tables provide the hanger geometry and dimensions, fastener schedules, and characteristic strength values
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views2 pages

Corrugated Hanger Specifications Guide

This document provides specifications for corrugated hangers used to connect wood joists. It includes: - Dimensions and material properties for 16 different hanger models with width ranging from 40-120mm. - Details on allowable fastener configurations (nails or screws) and their characteristic strength values for uniaxial and biaxial loading conditions. - Certification information confirming the hangers meet the requirements of EN 1995 and have an ETA-08/0264 CE marking. The hangers are made from S250 GD + Z275 steel with a thickness of 2.5mm. Tables provide the hanger geometry and dimensions, fastener schedules, and characteristic strength values
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CORROGATED HANGER

Certificates:

Mark CE: ETA-08/0264


Approval Z-9.1-65

Material:
Thickness:

S250 GD + Z275
2,5 mm

Geometry:
JOIST HANGER
Name

Catalogue
fixing
2009/2010

(TYP)

Code

BSA40110W

PF201100

BSA45108W

PF201105

BSA51105W

PF201110

BSA60100W

PF210115

BSA60130W

PF201120

BSA60160W

PF201200

BSA70125W

PF901365

BSA70155W

PF201205

BSA80120W

PF901370

BSA80150W

PF201135

BSA80180W

PF201210

BSA90145W

PF901375

BSA100140W

PF901380

BSA100170W

PF201150

BSA115163W

PF201155

BSA120160W

PF901385

Width
hanger
B
[mm]
40
45
51
60
60
60
70
70
80
80
80
90
100
100
115
120

DIMENSIONS HANGER
Width with
Height
First nail
flanges
hanger
hanger
H'N
H
A
[mm]
[mm]
[mm]
110
114
102,5
108
119
100,5
105
124
97,5
100
134
92,5
130
134
122,5
160
134
152,5
125
144
117,5
155
144
147,5
120
154
112,5
150
154
142,5
180
154
172,5
145
164
137,5
140
174
132,5
170
174
162,5
163
189
155,5
160
194
152,5

DIMENSIONS JOIST
Bearing
length

Width main joist BH,MIN


[mm]

Height secondary joist HN

BA
[mm]
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70

min
[mm]
122,5
120,5
117,5
112,5
142,5
172,5
137,5
167,5
132,5
162,5
192,5
157,5
152,5
182,5
172,5
172,5

max
[mm]
165
162
158
150
195
240
188
233
180
225
270
218
210
255
240
240

hanger on one hanger on two


side
sides

40
45
50
60
60
60
70
70
80
80
80
90
100
100
120
120

84
84
84
84
84
84
84
84
104
104
104
104
124
124
124
124

BN

>=20mm

a HH
B
A

Geometry - Front view

BH

BH
>=20mm

H'N

>=20mm

HN

BA

Lateral view - connection on 1 side

H'N

BA

Lateral view - connection on 2 sides

HN

CORROGATED HANGER
WOOD TO WOOD CONNECTION

= partial nailing
+ = full nailing
DIMENSIONS OF HANGER
B
[mm]

H
[mm]

40
45
51
60
60
60
70
70
80
80
80
90
100
100
115
120

110
108
105
100
130
160
125
155
120
150
180
145
140
170
163
160

nH
5
14
14
14
14
18
22
18
22
18
22
26
22
22
26
26
26

DIMENSIONS OF HANGER
B
[mm]

H
[mm]

40
45
51
60
60
60
70
70
80
80
80
90
100
100
115
120

110
108
105
100
130
160
125
155
120
150
180
145
140
170
163
160

CARACTERISTIC VALUES
Anker nails

Full nailing
nH
13
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4

nN
5
8
8
8
8
10
12
12
6
12
14
14
16
10
16
12
16

dn x

Nail
ln

4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 50
4,0 x 50
4,0 x 50
4,0 x 50
4,0 x 60
4,0 x 60
4,0 x 60
4,0 x 60

nH
13
-

FZ,Rk
[kN]
6,13
9,85
14,34
10,23
14,76
13,40
18,96
25,26
19,61
23,53
27,69
27,69
27,69

FY,Rk
[kN]
4,90
5,44
5,80
5,97
6,45
8,08
8,76
9,24
9,37
11,37
12,04
13,08
13,76

Screw 5
dn x ln
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40

CARACTERISTIC VALUES
Anker nails

Partial nailing
nH
5
8
8
8
8
10
12
10
12
10
12
14
12
12
14
14
14

FZ,Rk
[kN]
12,81
19,63
22,90
19,18
22,90
22,39
26,83
30,67
26,83
27,69
31,65
31,65
31,65

CARACTERISTIC VALUES
Screws

nN
5
4
4
4
4
5
6
5
6
5
6
7
6
6
7
7
7

Nail

dn x
ln

4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 40
4,0 x 50
4,0 x 50
4,0 x 50
4,0 x 50
4,0 x 60
4,0 x 60
4,0 x 60
4,0 x 60

FZ,Rk
[kN]
8,42
8,25
7,94
7,47
11,27
13,09
10,79
13,09
12,65
15,33
17,25
15,33
15,82
17,80
17,80
17,80

FZ,Rk
[kN]
3,37
3,45
3,55
3,75
5,76
8,11
6,00
8,38
7,83
10,72
13,42
11,11
11,87
13,85
13,85
13,85

FZ,Rk
[kN]
19,50
23,41
19,50
23,41
27,13
23,41
23,41
27,31
27,31
27,31

FY,Rk
[kN]
8,96
9,17
10,66
10,90
11,00
12,09
13,90
14,07
15,86
17,16

CARACTERISTIC VALUES
Screws
FY,Rk
[kN]
1,80
1,96
2,13
2,45
2,72
2,90
2,99
3,22
4,04
4,38
4,62
4,68
5,69
6,02
6,54
6,88

Screw 5
dn x ln
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40
5,0 x 40

FZ,Rk
[kN]
11,70
11,70
11,70
11,70
13,65
15,60
13,65
15,60
13,65
15,60
17,55
15,60
15,60
17,55
17,55
17,55

FZ,Rk
[kN]
7,80
7,80
7,80
7,80
9,75
11,70
9,75
11,70
9,75
11,70
13,65
11,70
11,70
13,65
13,65
13,65

FY,Rk
[kN]
2,41
2,69
3,02
3,74
3,89
3,97
4,48
4,59
5,33
5,45
5,50
6,05
6,95
7,04
7,93
8,58

,
,
+
1
,
,
2

Fz,Rk

Fy,Rk
e

Notes
- nH = number of fasteners (nails/screws 5 or dowels 13) in the main beam
Verification of the biaxial loading:
- nN = number of fasteners (nails/screws 5) in the secondary joist
'- Characteristic values calculated according to EN 1995 and in accordance with CE marking (ETA-08/0264)
Fz,Rk
'- Anker nails according to EN 14592
'- Screws according to EN 14592 and with Z-9.1-375 certification
'- The resistances refer respectively to:
FZ,Rk
force in vertical direction, downwards
[kN]
FZ,Rk
force in vertical direction, upwards
[kN]
FY,Rk
lateral force
[kN]
'- The lateral force is assumed to act at the upper edge of the hanger

FZ,Rk
[kN]
23,41
27,31
23,41
27,31
31,21
27,31
27,31
31,21
31,21
31,21

Fz,Rk

Fz,Rk

Uniaxial loading

Biaxial loading

You might also like