0% found this document useful (0 votes)
99 views60 pages

Adam 5510 TCP

This document provides an agenda and overview for a training on the ADAM-5510E TCP module. It includes sections on introducing the hardware specifications, internal file structure, utility functions, software functions, and demonstrations. The hardware specifications section details the CPU, memory, operating system, interfaces, and I/O module options. The internal file structure sections describe the organization of files on the module's drives. The utility functions section outlines common tasks like transferring files, configuring I/O and networking. An introduction to the software functions explains the additional communication protocols and libraries supported.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views60 pages

Adam 5510 TCP

This document provides an agenda and overview for a training on the ADAM-5510E TCP module. It includes sections on introducing the hardware specifications, internal file structure, utility functions, software functions, and demonstrations. The hardware specifications section details the CPU, memory, operating system, interfaces, and I/O module options. The internal file structure sections describe the organization of files on the module's drives. The utility functions section outlines common tasks like transferring files, configuring I/O and networking. An introduction to the software functions explains the additional communication protocols and libraries supported.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 60

ADAM-5510E TCP

2005 H2 AE Training
IAG/AE : Andersen Kao
Agenda
Introduction to Hardware
Specifications
Introduction to Internal File Structure
Introduction to Utility Functions
Introduction to Software Function
Demonstration of Software Function
Integrated Applications
Practice
Q & A
Introduction to Hardware
Specifications
CPU: 80188 microprocessor
Memory:
1.5MB flash memory:
- 256KB system Disk (Drive C: Read Only)
- 256KB flash memory (Accessed by Function LIB)
- 1024KB file system, 960KB for user applications (Drive D:
Read/Write)
640KB SRAM
- up to 384KB with battery backup (Accessed by Function LIB)
Operating System: ROM-DOS (MS-DOS 6.22 Compatible)
Real-time Clock: yes
Watchdog Timer: yes
Introduction to Hardware
Specifications
Memory Comm. Interface
1.5MB Flash Disk
256KB System Flash
256KB Flash Memory
1M File System
640KB SRAM
Up to 384KB Battery
Backup RAM
1 x 10/100 base-T Port
1 x RS-232 Programming Port
1 x RS-232 Port
1 x RS-485 Port
1 x RS-232/485 Port
Introduction To Hardware
Specifications
Real-time Clock for
Recording Event History
Real-time Clock for
Recording Event History
RS-485 Port for Modbus
Devices
RS-485 Port for Modbus
Devices
640KB SRAM with 384KB
Battery Backup
640KB SRAM with 384KB
Battery Backup
RS-232/485 Port for
Modbus Devices
RS-232/485 Port for
Modbus Devices
Versatile AI/AO/DI/DO
/Counter Modules
Versatile AI/AO/DI/DO
/Counter Modules
DIP Switch for Setting
ID & Configuration Tool
DIP Switch for Setting
ID & Configuration Tool
Ethernet Port for Connecting e-World
Ethernet Port for Connecting e-World
RS-232/485 Port for
Remote I/O Modules
RS-232/485 Port for
Remote I/O Modules
Power Supply Module
No Limitation for AO
Power Supply Module
No Limitation for AO
Extensive Flash Memory
Includes 1MB Disk Drive with
File System for Data Logging
File I/O
Extensive Flash Memory
Includes 1MB Disk Drive with
File System for Data Logging
File I/O
4 or 8 Slots Backplane
4 or 8 Slots Backplane
Prog. Port for Downloading
Programs
Prog. Port for Downloading
Programs
Support Panel Mounting
or Rack Mounting
Support Panel Mounting
or Rack Mounting
Introduction To Hardware
Specifications
- Supported Module List
Digital Module
5056 Digital Output Module
5056D Digital Output Module
5060 Relay Output Module
5068 Relay Output Module
5080 Counter/Frequency Module
5050 Digital I/O Module
5051D Digital Input Module
5051 Digital Input Module
5052 Isolated DI Module
Digital Input
Digital Output
Counter
Mixed I/O
Analog Module
5013 RTD Input Module
5017 Analog Input Module
5017H Analog Input Module
5018 T/C Input Module
5024 Analog Output Module
Analog Input
Analog Output
Communication Module
5090 Communication Module
Internal File Structure
-The File Structure of Drive C
AUTOEXEC BAT 57 04-03-2003 11:12a
COMMAND COM 35,181 07-18-2000 6:22a
TRANSFER EXE 11,944 02-11-1999 6:55p
VDISK SYS 8,032 03-20-2003 7:10a
CHKID EXE 6,520 04-26-2002 10:41a
CONFIG SYS 72 07-13-2000 4:18p
DLFFS EXE 14,936 01-14-2003 4:43p
DLFMT EXE 15,059 09-26-1996 3:01a
INIMODE EXE 6,636 04-03-2003 9:28a
MEM EXE 7,726 03-20-2003 7:10a
10 file (s) 106,163 bytes
0 bytes free
Internal File Structure
-The File Structure of Drive D
CONF <DIR> 09-11-2004 2:49p
WEBROOT <DIR> 09-11-2004 2:49p
AUTORUN BAT 128 09-11-2004 2:49p
AX8796 COM 13,312 09-11-2004 2:49p
CFGIO EXE 35,328 09-11-2004 2:50p
SOCKETP EXE 48,896 09-11-2004 2:50p
6 file (s) 97,664 bytes
816,128 bytes free
<CONF> SOCKET UPW (The Configuration File for IP Setting of ADAM-5510TCP)
SOCKET CFG (The Configuration File for Access Right of ADAM-5510
TCP)
<WEBROOT> HTTPD EXE (The Folder to Put HTTP/FTP Process)
FTPD EXE
Introduction to Utility
Function
Host PC File Area ADAM-5510 TCP File Area
ADAM-5510 TCP Consol Mode
Basic Utility Operation-
Transferfile
Step 1: Select COM port
Basic Utility Operation
-Transfer file
Step 2: Press Refresh button to display the files in driver D of ADAM-5510 TCP
Basic Utility Operation
-Transfer file
Step 3: Press Copy file to ADAM to transfer files from host to the controller
Basic Utility Operation
- Configure IO
Press ADAM Configuration button to setup the IO modules of the controller
Basic Utility Operation
- Configure ADAM-5510/TCP
Press ADAM-5510/TCP Configuration to setup the IP address of the controller
Basic Utility Operation
- Configure ADAM-5510/TCP
This part includes three different parameter settings and one system initial function
Setting System IP.
Setting FTP Access
Right.
Setting HTTP Access
Right.
System Initialization.
The Configuration Process of
Utility - Configure ADAM-
5510/TCP
System Initialization function is used for formatting disk D. After format is completed,
it will transfer default system files to disk D. You can also transfer different server utility
to disk D after formatting
If you want to transfer server utility to disk D after formatting,
you should select the items here. The files will be transfer into
a folder <WEBROOT>
The Configuration Process
of Utility - System backup
To prevent user from losing their source file, we provide a backup function to backup files from disk D to
host PC
The Configuration Process of
Utility - System backup
The backup process will generate an image file which allows image restores back to
ADAM-5510 TCP
Introduce to the Software
Function
With the original functions of ADAM-5510, ADAM-5510/TCP add 7
new Communication Protocols. It increases the integrating abilities
of the controller. The new functions are listed as below:
FTP (Client/Server)
HTTP (Client/Server)
MODBUS RTU (Client/Server)
ADAM-5090 with MODBUS RTU Client
MODBUS TCP (Client/Server)
E-MAIL
UDP (Client/Server)
TCP (Client/Server)
We provide the related Library Function or Utility for each individual
communication protocol. Each protocol will be introduced in further
detail in the following slides
Introduce to the Software
Function
Library Functions
Library Functions
System Functions
Communication Functions
Low Speed I/O Module Access Functions
High Speed I/O Module Access Functions
Counter/Frequency Module Access Functions
MODBUS/TCP Server/Client LIB Functions
MODBUS/RTU Master/Slave LIB Functions
Sockets LIB Functions (Winsock Compatible)
HTTP Function LIB for Showing Local Info
Utilities
Utilities
HTTP & FTP Server
FTP Client
Send Mail
Introduce to the Software
Function -
FTP server
FTP server
FTP is the protocol for file transfer. You can only keep the continual FTPD.
exe process by using the System Installation.
Step 1: Execute ADAM-5510/TCP Configuration utility and set up system IP
Address
Introduce to the Software
Function -
FTP server
FTP server
Step 2: Configure the User ID , Password and Access Right for
FTP/HTTP protocol
Note: FTP and HTTP accounts should be set up at the same time
Introduce to the Software
Function -
FTP server
FTP server
Step 3: Restart ADAM-5510 TCP after the configuration is done. You can
check your IP setting by monitoring the console windows of Utility.
Introduce to the Software
Function -
FTP server
FTP server
Step 4: Transfer the FTPD.exe from Host PC to the location
D:\WEBROOT\ of ADAM-5510/TCP
Introduce to the Software
Function -
FTP server
FTP server
Step 5: Execute FTPD /r under D:\WEBROOT\ in console mode. Then,
the FTP server will be in going residentmode
Go into the resident mode
Introduce to the Software
Function -
FTP server
FTP server
Step 6: Connect the FTP Server with IE Browser or some FTP client
softwares by using the id and password set previously. You can
also find the files under D:\WEBROOT\ from ADAM-5510 TCP
Introduce to the Software
Function -
FTP server
FTP server
Step 7: You can also upload the file to ADAM-5510/TCP thru FTP
protocol
Introduce to the Software
Function -
FTP client
FTP client
Step 1: In order to use FTP client, you should transfer the FTP.exe to
ADAM-5510 TCP
Introduce to the Software
Function -
FTP client
FTP client
Step 2: You can test the FTP client in console mode by logging in with
the correct ID/Password
Introduce to the Software
Function - Http Server
The application of HTTP Server is that user can monitor or control ADAM-
5510/TCP thru web browser. The processes are as follow:
(1)Registers a web page (user defined name.htm) from Server
(2) Browse the page thru browser
(3)Exchange the status between hardware and web page thru CGI interface.
HTML CGI
5510
LIB
Ethernet
User/IE browser
HTTP Server
Introduce to the Software
Function - Http Server
Step 1: Upload the HTTPD. exe to ADAM-5510/TCP thru utility
Introduce to the Software
Function - Http Server
Step 2: Execute HTTPD.EXE to keep the files running from the HTTP
Server to system
Step 3: Upload User program to ADAM-5510TCP and execute it
Introduce to the Software
Function - Http Server
Step 4: Connect to ADAM-5510TCP thru IE browser with correct
ID/Password
Introduce to the Software
Function - Http Server
Step 5: Monitoring ADAM-5510/TCP I/O Status thru IE browser
Introduce to the Software
Function - Modbus RTU
The structure of Modbus can be divided into Client and Server Client and Server.
Server is a data provider such as our ADAM-4000 Modbus series modules. They
belong to the Modbus Server.
The other one is called Modbus Client which requests data from Modbus Server.
Most of the SCADA software play as the role of a Client.
ADAM-5510/TCP provides related library functions for both Client and Server.
ADAM-4000
Modbus Server
Modbus Client
RS-485
SCADA
Modbus Client
Modbus Server
RS-485
Introduce to the Software
Function - Modbus RTU
We provide 8 function codes for Modbus Client as follows:
01: Read coil status (0X)
02: Read Input status (1X)
03: Read Holding register (4X)
04: Read Input register (3X)
05: Force Single coil (0X)
06: Preset Single register (4X)
0F: Force Multiple coils (0X)
10: Preset Multiple registers (4X)
We also provide the related demo program for testing, and will
introduce details for each of them in the following slides
Introduce to the Software
Function - Modbus RTU
01:
bool ADAMRTU_ReadCoilStatus(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
02:
bool ADAMRTU_ReadInputStatus(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
Introduce to the Software
Function - Modbus RTU
03:
bool ADAMRTU_ReadHoldingRegs(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
04:
bool ADAMRTU_ReadInputRegs(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
Introduce to the Software
Function - Modbus RTU
05:
bool ADAMRTU_ForceSingleCoil(
int iPort,
int i_iAddr,
int i_iCoilIndex,
int i_iData
);
06:
bool ADAMRTU_PresetSingleReg(
int iPort,
int i_iAddr,
int i_iRegIndex,
int i_iData
);
Introduce to the Software
Function - Modbus RTU
0F:
bool ADAMRTU_ForceMultiCoils(
int iPort,
int Slave_Addr,
int CoilIndex,
int TotalPoint,
int TotalByte,
unsigned char szData[]
);
10:
bool ADAMRTU_PresetMultiRegs(
int iPort,
int i_iAddr,
int i_iStartReg,
int i_iTotalReg,
int i_iTotalByte,
unsigned char i_szData[]
);
Introduce to the Software
Function - Modbus RTU
Initial Modbus Port:
int Modbus_COM_Init(
int Port,
int iMode,
unsigned long iBaud,
int iParity,
int iFormat,
int iStopBits
);
Release Modbus Port:
void Modbus_COM_Release(int Port);
Error Check:
int Error_Code(void);
Introduce to the Software
Function - Modbus RTU
For Modbus Server, only one process should be executed in order
to provide accesses to the data for the Client.
Modbus Server:
void ADAMRTU_ModServer_Create(
int slave_addr,
unsigned char * ptr_mem,
unsigned int size_of_mem
);
Introduce to the Software
Function - Modbus RTU
Aside from default settings, COM port can get data from Modbus
Server. We can also get Modbus Server data thru ADAM-5090 to
increase system integration ability
The limitation for ADAM-5090 is that ADAM-5090 can only be a
Modbus client and can't be a Modbus Server
RS-232
RS-485
ADAM-5090
ADAM-4520 ADAM-4055
Introduce to the Software
Function - Modbus RTU
01:
bool A5090_RTU_ReadCoilStatus(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
02:
bool A5090_RTU_ReadInputStatus(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
Introduce to the Software
Function - Modbus RTU
03:
bool A5090_RTU_ReadHoldingRegs(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
04:
bool A5090_RTU_ReadInputRegs(
int iPort,
int i_iAddr,
int i_iStartIndex,
int i_iTotalPoint,
int *o_iTotalByte,
unsigned char o_szData[]
);
Introduce to the Software
Function - Modbus RTU
05:
bool A5090_RTU_ForceSingleCoil(
int iPort,
int i_iAddr,
int i_iCoilIndex,
int i_iData
);
06:
bool A5090_RTU_PresetSingleReg(
int iPort,
int i_iAddr,
int i_iRegIndex,
int i_iData
);
Introduce to the Software
Function - Modbus RTU
0F:
bool A5090_RTU_ForceMultiCoils(
int iPort,
int Slave_Addr,
int CoilIndex,
int TotalPoint,
int TotalByte,
unsigned char szData[]
);
10:
bool A5090_RTU_PresetMultiRegs(
int iPort,
int i_iAddr,
int i_iStartReg,
int i_iTotalReg,
int i_iTotalByte,
unsigned char i_szData[]
);
Introduce to the Software
Function - Modbus RTU
Initial Modbus Port:
int Modbus_5090_Init(
int Port,
unsigned long iBaud,
int iParity,
int iFormat,
int iStopBits
);
Release Modbus Port:
void Modbus_5090_Release(int Port);
Error Check:
int Error_Code(void);
Introduce to the Software
Function - Modbus TCP
Aside from MODBUS TCP, ADAM-5510 TCP also provide the
related library function for both Client and Server.
ADAM-5510 TCP/Modbus Client/Server
SCADA/Modbus Client
HUB ADAM-6000
Modbus Server
Introduce to the Software
Function - Modbus TCP
MODBUS TCP CLIENT:
01:
int ADAMTCP_ReadCoilStatus( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int StartIndex,
int TotalPoint,
int * ByteCount,
char * wData
);
02:
int ADAMTCP_ReadInputStatus( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int StartIndex,
int TotalPoint,
int * ByteCount,
char * wData
);
Introduce to the Software
Function - Modbus TCP
03:
int ADAMTCP_ReadHoldingRegs( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int StartIndex,
int TotalPoint,
int * ByteCount,
char * wData
);
04:
int ADAMTCP_ReadInputRegs( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int StartIndex,
int TotalPoint,
int * ByteCount,
char * wData
);
Introduce to the Software
Function - Modbus TCP
05:
int ADAMTCP_ForceSingleCoil(
SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int CoilIndex,
int Data
);
06:
int ADAMTCP_PresetSingleReg(
SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int RegIndex,
int Data
);
Introduce to the Software
Function - Modbus TCP
0F: int ADAMTCP_ForceMultiCoils( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int CoilIndex,
int TotalPoint,
int TotalByte,
unsigned char szData[]
);
10: int ADAMTCP_PresetMultiRegs( SOCKET * SO,
int WaitMilliSec,
int Slave_Addr,
int StartReg,
int TotalReg,
int TotalByte,
unsigned char Data[]
);
Introduce to the Software
Function - Modbus TCP
MODBUS TCP Client connect:
int ADAMTCP_Connect(
SOCKET * SO,
char * Target_IP,
int Target_Port
);
TCP/IP Disconnect:
bool ADAMTCP_Disconnect(SOCKET * SO);
Error Check:
int ReturnErr_code(void);
Introduce to the Software
Function - Modbus TCP
MODBUS TCP SERVER:
Server Create:
int ADAMTCP_ModServer_Create(
int Host_Port,
unsigned long waittimeout,
unsigned int numberConns,
unsigned char * ptr_mem,
int size_mem
);
Server Update:
int ADAMTCP_ModServer_Update(void);
Server Release:
void ADAMTCP_ModServer_Release(void);
Introduce to the Software
Function - Modbus TCP
Here is an example program for combining the Modbus TCP
Server with Modbus TCP Client.
SCADA
SYSTEM
Modscan is to be a Modbus Client and get data from 5510
Modbus server
6024
TCP/IP
Utility shows that
ADAM-5510 TCP gets
data from Modbus
Server (ADAM6000)
Introduce to the Software
Function - eMail
Away from the communication protocol above, ADAM-5510/TCP has a new function for
Email. It is a useful function which sends mail automatically when the system are in
warning or abnormal states. It can also avoid some kind of mistake which may cause a
severe damage
The Email function of ADAM-5510/TCP is made by two programs. One for " MakeMail.exe"
and the other for " SendMail.exe" .
User can only create a text file by using editor and save it into a " .DAT" file thru
" MakeMail.exe" . Then send the mail message by using " SendMail.exe"
Note: There is a key point should be check. The function for sending a mail is thru the
" SMTP Server . You should check if the IP of SMTP Mail Server is delivering the mail with
the IP setting of ADAM-5510/TCP. We dont provide the Authorized SMTP Server
Alarm!!
Introduce to the Software
Function - Socket
We also provide the Socket Library by providing the
related example program and library function for TCP
or UDP
TCP Client UDP Client UDP Server TCP Server
Introduce to the Software
Function - Socket
TCP Server
TCP Client
Thank You!!