Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
E
E
E
E
E
E
E
E
E
E
E
ISI-500
series
Features :
High surge power up to 1000W
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over temp.
/ Output short / Input polarity reverse / Over load
High frequecny design
SPECIFICATION
MODEL
ISI-500-112
350W
RATED POWER
ISI-500-124
AC Output voltage regulation : 10%
AC Output wavform : Modified sine wave
Modified models available(optional): 100/115/120VAC or 200/220/240VAC
Cooling fan ON-OFF control
Built-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.)
Built-in battery low relay contact
LED indicator for operation status
2 years warranty
ISI-500-148
500W
500W
ISI-500-212
350W
ISI-500-224
500W
ISI-500-248
500W
MAXIMUM OUTPUT POWER (Typ.) 550W for 1 minute / surge power 1000W for 30 cycles (112, 212 models : 385W for 1 minute / surge power 700W for 30 cycles)
WAVEFORM
Modified sine wave
OUTPUT
AC VOLTAGE
110V
230V
FREQUENCY
60Hz 0.5Hz
50Hz 0.5Hz
10%
LED INDICATOR
BAT. VOLTAGE
Green: Inverter OK Green (flashing): Inverter OK and charging Red: abnormal
24V
24V
48V
12V
12V
42 ~ 60VDC
10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
25A
12.5A
35A
25A
12.5A
0.4A
0.2A
0.8A
0.4A
0.2A
87%
Open & sealed Lead Acid
87%
86%
88%
88%
BATTERY TYPE
VOLTAGE RANGE
20 ~ 40V
Note.3,4 10.5 ~ 15VDC
DC CURRENT (Typ.)
35A
NO LOAD CURRENT DRAW
0.8A
OFF MODE CURRENT DRAW 1mA
EFFICIENCY (Typ.)
SOLAR
PANEL
INPUT
48V
21 ~ 30VDC
VOLTAGE RANGE
INPUT
AC REGULATION
Note.1 85%
35 ~ 80V
70 ~ 160V
70 ~ 160V
15A
7.5A
20 ~ 40V
15A
35 ~ 80V
MAX. SHORT CIRCUIT CURRENT 15A
15A
7.5A
RATED CHARGE POWER (Typ.) 350W
14V
500W
28V
500W
56V
350W
14V
500W
28V
500W
20A
10A
25A
20A
30A
22V
15A
44V
40A
11V
30A
22V
21V
42V
10.5V
21V
MAX. CHARGE VOLTAGE
SOLAR
CHARGER MAX. CHARGE CURRENT
25A
FUSE
40A
BATTERY BAT. LOW ALARM
Note.4 11V
INPUT
PROTECTION BAT. LOW SHUTDOWN Note.4 10.5V
By internal fuse
REVERSE POLARITY
OVER TEMPERATURE
OUTPUT
PROTECTION OUTPUT SHORT
OVER LOAD
70
J10J
65
56V
10A
15A
44V
42V
J10J
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect on power transistor
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec.
FUNCTION BAT. LOW RELAY CONTACT Open : Battery low ; Short : Battery ok
WORKING TEMP.
Note.2 -20 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT
o
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH
VIBRATION
LVD
WITHSTAND VOLTAGE
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
EN60950-1
None
Bat. I/P - AC O/P:3.0KVAC
AC O/P - FG:1.5KVAC
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMS IMMUNITY
MTBF
81.1K hrs min.
OTHERS
DIMENSION
PACKING
205*158*67mm (L*W*H)
1.92Kg; 6pcs/12.5Kg/1.55CUFT
NOTE
Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class A
Compliance to FCC part 15 class A
None
Compliance to EN61000-4-2,3,8
o
MIL-HDBK-217F (25 C)
1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.Input derating capacity referenced by curve 2.
4.The tolerance of each voltage value by models is:112/212
0.5V;124/224
1V;148/248
2V.
5.All parameters not specified above are measured at rated load, 25 of ambient temperature.
File Name:ISI-500-SPEC 2013-01-14
ISI-500
Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI
500
112 A
A :TYPE
B :TYPE
C :TYPE
D :TYPE
E :TYPE
U :TYPE
12:12VDC
Bat. Voltage: 24:24VDC
48:48VDC
Modified sine wave inverter
+MPPT solar charger
Output:
O/P Wattage:500W
1:110VAC
2:230VAC
series
A OUTLET
B OUTLET
C OUTLET
D OUTLET
E OUTLET
U OUTLET
AC Output Receptacles (optional)
Receptacle type
TYPE-A
(Standard)
TYPE-B
(Standard)
TYPE-C
(Optional)
TYPE-D
(Optional)
TYPE-E
(Optional)
TYPE-U
(Optional)
USA
EUROPE
AUSTRALIA
U.K
JAPAN
UNIVERSAL
Country
Certificate
Non
Mechanical Specification
Unit:mm
5
Input Terminal Pin No. Assignment
2 1
67
Pin No.
1
2
3
Assignment
FG
Solar POS(+)
Solar NEG(-)
Pin No.
4
5
Assignment
Battery POS(+)
Battery NEG(-)
SOLAR INPUT
BATTERY INPUT
Derating Curve
Reverse Polarity
Will Damage The Unit.
100
11
7.62
Air flow
direction
6.35
80
42.5
LOAD (%)
13
18
8.9
60
50
40
20
-20
10
20
30
40
50
60
70
(HORIZONTAL)
ENVIRONMENT TEMPERATURE ( )
120
205
CURVE 1
100
LOAD (%)
80
60
40
20
10.5VDC
11.5VDC
15VDC
(HORIZONTAL)
147
BATTERY INPUT VOLTAGE (V)
CURVE 2
158
AC OUTPUT
OFF
Bat. Low Status
alarm
Type-A
AC OUTPUT
ON
ON
OFF
Bat. Low Relay Connector :
JST B-XH or equivalent
Open
Short
Battery low
Battery OK
Bat. Low Status
alarm
Type-B
File Name:ISI-500-SPEC 2013-01-14