Setup Information
Studio 5000 Logix Designer
Level 1: ControlLogix
Fundamentals and
Troubleshooting
Table of Contents
General Setup: Studio 5000 Logix Designer Level 1: ControlLogix Fundamentals
and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exercise Setup: Locating ControlLogix System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exercise Setup: Navigating Through the Logix Designer Application . . . . . . . . . . . . . . . . . . . . . . . . .
Exercise Setup: Connecting a Computer to a Communications Network in a Logix5000 System . . . . .
Exercise Setup: Downloading and Going Online to a Logix5000 Controller . . . . . . . . . . . . . . . . . . . .
11
Exercise Setup: Locating I/O Tags and Devices in a ControlLogix System . . . . . . . . . . . . . . . . . . . . .
13
Exercise Setup: Interpreting Logix Designer Project Organization and Execution . . . . . . . . . . . . . . . .
15
Exercise Setup: Interpreting Ladder Logic Structure in a Logix Designer Routine . . . . . . . . . . . . . . . .
17
Exercise Setup: Locating and Editing Tag Values in a Logix Designer Project . . . . . . . . . . . . . . . . . . .
19
Exercise Setup: Interpreting Bit Instructions in a Logix Designer Routine . . . . . . . . . . . . . . . . . . . . . .
21
Exercise Setup: Interpreting Frequently Used Instructions in a Logix Designer Routine . . . . . . . . . . . .
23
Exercise Setup: Interpreting Arrays in a Logix Designer Project . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
Exercise Setup: Interpreting Tags of User-Defined Data Types in a Logix Designer Project . . . . . . . . .
27
Exercise Setup: Searching for Project Components in a Logix Designer Project . . . . . . . . . . . . . . . . .
29
Exercise Setup: Integrated Practice - Interpreting a Basic Logix Designer Project . . . . . . . . . . . . . . .
31
Exercise Setup: Forcing I/O and Toggling Bits in the Logix Designer Application . . . . . . . . . . . . . . . . .
33
Exercise Setup: Troubleshooting 1756 Digital I/O Module Problems . . . . . . . . . . . . . . . . . . . . . . . . .
35
Exercise Setup: Troubleshooting 1756 Analog I/O Module Problems . . . . . . . . . . . . . . . . . . . . . . . . .
37
Exercise Setup:Troubleshooting 1756 Remote I/O Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Exercise Setup: Updating Logix5000 Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
Exercise Setup:Troubleshooting ControlLogix Controller Problems . . . . . . . . . . . . . . . . . . . . . . . . . .
43
Exercise Setup: Troubleshooting ControlLogix Power Supply Problems . . . . . . . . . . . . . . . . . . . . . . .
45
Exercise Setup: Analyzing and Troubleshooting a System Using a Logix Designer Trend Chart . . . . . .
47
Exercise Setup: Integrated Practice - Troubleshooting Basic Logix Designer Projects . . . . . . . . . . . .
49
Exercise Setup: Editing Ladder Logic Online in a Logix Designer Project . . . . . . . . . . . . . . . . . . . . . .
51
Exercise Setup: Managing Logix Designer Project Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
53
ii
Table of Contents
Exercise Setup: Documenting and Printing Components in a Logix Designer Project . . . . . . . . . . . . .
55
Exercise Setup: Troubleshooting Noise-Related Problems in a Logix5000 System . . . . . . . . . . . . . . .
57
Exercise Setup: Understanding Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59
General Setup: Studio 5000 Logix Designer Level 1: ControlLogix Fundamentals and Troubleshooting
General Setup: Studio 5000 Logix
Designer Level 1: ControlLogix
Fundamentals and Troubleshooting
Introduction
This document contains information about the setup steps required to
prepare for course CCP299.
Several Weeks Before Use
Ordering Checklist
The following equipment is required for each workstation:
- A computer that meets the minimum requirements necessary
to run all application software:
Software
Version
.NET Framework
4.0
Studio 5000
21.0
RSLogix 5000 Compare Tool
3.4
Firmware files for Studio 5000
21.0
RSLinx Classic
3.51
Microsoft PowerPoint or Microsoft PowerPoint
Viewer
2002 or newer
- ControlLogix workstation (Part No. ABT-TDCLX3) or
equivalent hardware
- Communication cards and cables for an EtherNet/IP network
- SAMTEC RSP-119350 USB cable (or equivalent; for
communications between L73 controller and computer)
Tip "
Job Aids
See the Workstation Layout section of this General Setup document
for more information and workstation configuration details.
The following job aids can be used to complete the exercises:
Logix5000 Systems Glossary
Studio 5000 Logix Designer and Logix5000 Procedures Guide
ControlLogix Troubleshooting Guide
Logix5000 Documentation Reference Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
CCP299_GeneralSetup
General Setup: Studio 5000 Logix Designer Level 1: ControlLogix Fundamentals and Troubleshooting
Day Before Use
Required Setup
Perform the following steps for each workstation:
If the classroom layout does not allow
easy networking through hubs and
switches, you can have students directly
connect the workstation and computer
using a crossover Ethernet cable.
- Unzip the Student Exercise Files and place them on each
student PC.
- Copy the Node Assignments appendix for each workstation.
- Restore Logix Designer application to its default settings by
performing the following actions:
- If it is open, close Logix Designer application.
- Press and hold the CTRL + SHIFT key combination.
- Continue holding the CTRL + SHIFT key combination and
start the software.
- Do not release the CTRL + SHIFT key combination until the
software has started.
- Set the default directory under Tools!Options.
- In the default project directory, delete all old files.
- On the desktop, make a shortcut for each software.
- Set up an Ethernet/IP network and assign IP addresses to the
computers and EtherNet/IP modules.
- Verify the ControlLogix workstation matches the standard
hardware layout found in the Workstation Layout section of
this document.
If you are using a non-standard workstation
configuration, you will have to modify the I/O
configurations for each Student Exercise file to
match your hardware layout.
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
CCP299_GeneralSetup
General Setup: Studio 5000 Logix Designer Level 1: ControlLogix Fundamentals and Troubleshooting
Workstation Layout
The ControlLogix workstation (or equivalent custom setup) used in
the course requires the following equipment:
12 dual input and output pushbuttons
4 selector switches (on/off)
2 analog inputs
2 analog meters
A 10-slot chassis with the modules listed in the following table:
To match the standard workstation configuration
in the exercise files, the workstations modules
must be placed in the following slots:
Slot
Module
Description
1756-OB16D
Digital output module (DO0 to DO5)
1756-L73 (5573)
ControlLogix Controller
1756-IB16D
Digital input module (DI0 to DI15)
Empty slot
1756-OB16D
Digital output module (D06 to DO11)
1756-CNB
ControlNet bridge module
1756-DHRIO
Data Highway/Remote I/O bridge module
1756-OF6VI
Analog output module
1756-IF6I
Analog input module
1756-ENxT
EtherNet/IP bridge module
If your workstations do not include 1756-DHRIO
modules, you should leave Slot 6 empty.
The workstations modules must have firmware
compatible with Studio 5000 version 21.
Tip "
Rev. September 2013
Firmware files are available at:
http://support.rockwellautomation.com/ControlFlash/
E 2013 Rockwell Automation, Inc. All rights reserved.
CCP299_GeneralSetup
General Setup: Studio 5000 Logix Designer Level 1: ControlLogix Fundamentals and Troubleshooting
The layout of the workstation is shown in the following graphic:
10-Slot ControlLogix
Chassis
12 Dual Discrete
Inputs/Outputs
Status
Sta tus
J5
J5
DC Bus
J2
L1
100-240
VAC
50/60 Hz
L2/N
J1
J1
Motor
Motor
Adva nta ge Line
2 Analog Meters
100-240
VAC
50/60 Hz
4 Selector
Switches
Motion Equipment
(Not Required)
DC Bus
J2
L1
L2/N
Ad vantage Line
2 Analog Inputs
(Potentiometers)
The following ControlLogix workstation inputs and outputs are used
in this course:
Inputs
Outputs
Green
Pushbuttons
DI0
DO0
DI1
DI2
DO3
DO6
Amber
Pushbuttons
DI4
DI5
DI6
DO1
DO4
DO7
DO10
DI8
DO2
DI9
DI10
DI11
DO5
DO8
DO11
Red
Pushbuttons
Selector
Switches
DI12
E 2013 Rockwell Automation, Inc. All rights reserved.
DI13
DI14
DI3
DO9
DI7
DI15
Rev. September 2013
CCP299_GeneralSetup
Exercise Setup: Locating ControlLogix System Components
Exercise Setup: Locating
ControlLogix System Components
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation or equivalent hardware
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
N/A
Exercise Setup
N/A
Recommended Job Aids
The following job aid is recommended for use with this exercise:
Logix5000 System Glossary
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
CM3e56r_Setup
Exercise Setup: Locating ControlLogix System Components
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
CM3e56r_Setup
Exercise Setup: Navigating Through the Logix Designer Application
Exercise Setup: Navigating
Through the Logix Designer
Application
Required Hardware and
Software
The following hardware and software is required for this exercise:
Computer with the following software installed:
- Studio 5000
- RSLinx Classic
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
The exercise requires the following files:
NAV_1756r_A1.acd
NAV_1756r_A2.acd
Exercise Setup
Before performing this exercise, return Logix Designer application
to default settings by performing the following actions:
1. If it is open, close the Logix Designer application.
2. Press and hold the CTRL + SHIFT key combination.
3. Continue holding the CTRL + SHIFT key combination and start
the software.
Do not release the CTRL and SHIFT keys until
the software has started.
The software is restored to default settings.
Recommended Job Aids
The following job aids are recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Logix5000 System Glossary
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
NAVe56r_Setup
Exercise Setup: Navigating Through the Logix Designer Application
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
NAVe56r_Setup
Exercise Setup: Connecting a Computer to a Communications Network in a Logix5000 System
Exercise Setup: Connecting a
Computer to a Communications
Network in a Logix5000 System
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
SAMTEC RSP-119350 USB cable (or equivalent)
EtherNet/IP network
Computer with the following software installed:
- RSLinx Classic Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP153.
Exercise File
N/A
Exercise Setup
If any drivers are configured in RSLinx Classic software, stop them
and delete them before beginning this exercise.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
NE3e56r_setup
10
Exercise Setup: Connecting a Computer to a Communications Network in a Logix5000 System
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
NE3e56r_setup
Exercise Setup: Downloading and Going Online to a Logix5000 Controller
11
Exercise Setup: Downloading and
Going Online to a Logix5000
Controller
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
Networks and configured drivers:
- Serial (cable connected to the computer but not the controller)
- EtherNet/IP
Computer with the following software installed:
- Studio 5000
- RSLinx Classic Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
DG3_1756R_A1.acd
Exercise Setup
Serial and EtherNet/IP drivers must be configured for the network
using the default names.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
DG3e56r_setup
12
Exercise Setup: Downloading and Going Online to a Logix5000 Controller
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
DG3e56r_setup
Exercise Setup: Locating I/O Tags and Devices in a ControlLogix System
13
Exercise Setup: Locating I/O Tags
and Devices in a ControlLogix
System
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
IT3_1756r_A1.acd
Exercise Setup
When preparing for this exercise, keep the following points in mind:
Be sure the following appendices are available from the exercise:
- I/O Wiring Diagrams
- I/O Wiring Diagrams for the HVAC System Application
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
NA
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
IT3e56r_setup
14
Exercise Setup: Locating I/O Tags and Devices in a ControlLogix System
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
IT3e56r_setup
Exercise Setup: Interpreting Logix Designer Project Organization and Execution
15
Exercise Setup: Interpreting Logix
Designer Project Organization and
Execution
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
TS3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
N/A
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
TS3e56r_setup
16
Exercise Setup: Interpreting Logix Designer Project Organization and Execution
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
TS3e56r_setup
Exercise Setup: Interpreting Ladder Logic Structure in a Logix Designer Routine
17
Exercise Setup: Interpreting Ladder
Logic Structure in a Logix Designer
Routine
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
ILL_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aids
N/A
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
ILLe56r_Setup
18
Exercise Setup: Interpreting Ladder Logic Structure in a Logix Designer Routine
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
ILLe56r_Setup
Exercise Setup: Locating and Editing Tag Values in a Logix Designer Project
19
Exercise Setup: Locating and
Editing Tag Values in a Logix
Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following files:
TA3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
TA3e56r_setup
20
Exercise Setup: Locating and Editing Tag Values in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
TA3e56r_setup
Exercise Setup: Interpreting Bit Instructions in a Logix Designer Routine
21
Exercise Setup: Interpreting Bit
Instructions in a Logix Designer
Routine
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
IBI_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aids
The following job aid is recommended for use with this exercise:
Logix5000 Documentation Reference Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
IBIe56r_Setup
22
Exercise Setup: Interpreting Bit Instructions in a Logix Designer Routine
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
IBIe56r_Setup
Exercise Setup: Interpreting Frequently Used Instructions in a Logix Designer Routine
23
Exercise Setup: Interpreting
Frequently Used Instructions in a
Logix Designer Routine
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation or equivalent hardware
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise File
This exercise requires the following file:
IC3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aids
The following job aids are recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Logix5000 Documentation Reference Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
IC3e56r_setup
24
Exercise Setup: Interpreting Frequently Used Instructions in a Logix Designer Routine
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
IC3e56r_setup
Exercise Setup: Interpreting Arrays in a Logix Designer Project
25
Exercise Setup: Interpreting Arrays
in a Logix Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
AR3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
AR3e56r_setup
26
Exercise Setup: Interpreting Arrays in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
AR3e56r_setup
Exercise Setup: Interpreting Tags of User-Defined Data Types in a Logix Designer Project
27
Exercise Setup: Interpreting Tags
of User-Defined Data Types in a
Logix Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
UD3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
UD3e56r_setup
28
Exercise Setup: Interpreting Tags of User-Defined Data Types in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
UD3e56r_setup
Exercise Setup: Searching for Project Components in a Logix Designer Project
29
Exercise Setup: Searching for
Project Components in a Logix
Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following files:
SL3_1756R_A1.acd
SL3_1756R_B1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
SL3e56r_setup
30
Exercise Setup: Searching for Project Components in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
SL3e56r_setup
Exercise Setup: Integrated Practice - Interpreting a Basic Logix Designer Project
31
Exercise Setup:
Integrated Practice - Interpreting a
Basic Logix Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
IP3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
IP3e56r_setup
32
Exercise Setup: Integrated Practice - Interpreting a Basic Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
IP3e56r_setup
Exercise Setup: Forcing I/O and Toggling Bits in the Logix Designer Application
33
Exercise Setup: Forcing I/O and
Toggling Bits in the Logix Designer
Application
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
FO3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
FO3e56r_setup
34
Exercise Setup: Forcing I/O and Toggling Bits in the Logix Designer Application
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
FO3e56r_setup
Exercise Setup: Troubleshooting 1756 Digital I/O Module Problems
35
Exercise Setup: Troubleshooting
1756 Digital I/O Module Problems
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
Exercise Files
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
This exercise requires the following files:
DI3_1756R_A1.pps
DI3_1756R_A2.pps
DI3_1756R_B1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
DI3e56r_setup
36
Exercise Setup: Troubleshooting 1756 Digital I/O Module Problems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
DI3e56r_setup
Exercise Setup: Troubleshooting 1756 Analog I/O Module Problems
37
Exercise Setup: Troubleshooting
1756 Analog I/O Module Problems
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
Exercise Files
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
This exercise requires the following files:
AN3_1756R_A1.pps
AN3_1756R_A2.pps
AN3_1756R_B1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
AN3e56r_setup
38
Exercise Setup: Troubleshooting 1756 Analog I/O Module Problems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
AN3e56r_setup
Exercise Setup:Troubleshooting 1756 Remote I/O Problems
39
Exercise Setup:Troubleshooting
1756 Remote I/O Problems
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
CN3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
CN3e56r_setup
40
Exercise Setup:Troubleshooting 1756 Remote I/O Problems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
CN3e56r_setup
Exercise Setup: Updating Logix5000 Firmware
41
Exercise Setup: Updating
Logix5000 Firmware
Required Hardware and
Software
The following hardware and software is required for this exercise:
Computer with the following software installed:
- Studio 5000
- RSLinx Classic
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
N/A
Exercise Setup
N/A
Recommended Job Aids
The following job aids are recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
FW3e56r_Setup
42
Exercise Setup: Updating Logix5000 Firmware
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
FW3e56r_Setup
Exercise Setup: Troubleshooting ControlLogix Controller Problems
43
Exercise Setup: Troubleshooting
ControlLogix Controller Problems
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
Exercise Files
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
This exercise requires the following files:
LE3_1756R_A1.acd
LE3_1756R_B1.acd
LE3_1756R_B1_ANS.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
LE3e56r_setup
44
Exercise Setup: Troubleshooting ControlLogix Controller Problems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
LE3e56r_setup
Exercise Setup: Troubleshooting ControlLogix Power Supply Problems
45
Exercise Setup: Troubleshooting
ControlLogix Power Supply
Problems
Required Hardware and
Software
The following hardware and software is required for this exercise:
Computer with the ability to run a flash animation execution file.
Exercise File
This exercise requires the following file:
PS3_1756R_B1.exe
Exercise Setup
N/A
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
PS3e56r_setup
46
Exercise Setup: Troubleshooting ControlLogix Power Supply Problems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
PS3e56r_setup
Exercise Setup: Analyzing and Troubleshooting a System Using a Logix Designer Trend Chart
47
Exercise Setup: Analyzing and
Troubleshooting a System Using a
Logix Designer Trend Chart
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
TR3_1756R_A1.acd
TR3_1756R_B1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
TR3e56r_setup
48
Exercise Setup: Analyzing and Troubleshooting a System Using a Logix Designer Trend Chart
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
TR3e56r_setup
Exercise Setup: Integrated Practice - Troubleshooting Basic Logix Designer Projects
49
Exercise Setup: Integrated
Practice - Troubleshooting Basic
Logix Designer Projects
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following files:
LB3_1756R_A1.acd
LB3_1756R_A2.acd
LB3_1756R_A3.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aids
The following job aids are recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
LB3e56r_setup
50
Exercise Setup: Integrated Practice - Troubleshooting Basic Logix Designer Projects
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
LB3e56r_setup
Exercise Setup: Editing Ladder Logic Online in a Logix Designer Project
51
Exercise Setup: Editing Ladder
Logic Online in a Logix Designer
Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following file:
EN3_1756R_A1.acd
Exercise Setup
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
EN3e56r_setup
52
Exercise Setup: Editing Ladder Logic Online in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
EN3e56r_setup
Exercise Setup: Managing Logix Designer Project Files
53
Exercise Setup: Managing Logix
Designer Project Files
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
Exercise File
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
This exercise requires the following file:
FI3_1756R_A1.ACD
FI3_1756R_B1.ACD
FI3_1756R_B2.ACD
Exercise Setup
N/A
Recommended Job Aid
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
FI3e56r_setup
54
Exercise Setup: Managing Logix Designer Project Files
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
FI3e56r_setup
Exercise Setup: Documenting and Printing Components in a Logix Designer Project
55
Exercise Setup: Documenting and
Printing Components in a Logix
Designer Project
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation
EtherNet/IP network
Computer with the following software installed:
- Studio 5000
- RSLinx Classic OEM or Gateway with an activation file
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
This exercise requires the following files:
DC3_1756R_A1.acd
Exercise Setup
To facilitate the exercise, perform the following actions:
Write down the path for the default project directory as a
reference.
Verify that the student computers have Adobe Acrobat or similar
program that can print documents to PDF.
An EtherNet/IP driver must be configured using RSLinx Classic
software.
Recommended Job Aid
Rev. September 2013
The following job aid is recommended for use with this exercise:
Studio 5000 Logix Designer and Logix5000 Procedures Guide
E 2013 Rockwell Automation, Inc. All rights reserved.
DC3e56r_setup
56
Exercise Setup: Documenting and Printing Components in a Logix Designer Project
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
DC3e56r_setup
Exercise Setup: Troubleshooting Noise-Related Problems in a Logix5000 System
57
Exercise Setup: Troubleshooting
Noise-Related Problems in a
Logix5000 System
Required Hardware and
Software
N/A
Exercise Files
N/A
Exercise Setup
N/A
Recommended Job Aid
The following job aid is recommended for use with this exercise:
ControlLogix Troubleshooting Guide
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
NO3e56r_setup
58
Exercise Setup: Troubleshooting Noise-Related Problems in a Logix5000 System
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
NO3e56r_setup
Exercise Setup: Understanding Control Systems
59
Exercise Setup: Understanding
Control Systems
Required Hardware and
Software
The following hardware and software is required for this exercise:
ControlLogix workstation or equivalent hardware
Computer with the following software installed:
- Studio 5000
- RSLinx Classic
Tip "
For more detailed hardware, software, and workstation information,
see the General Setup for CCP299.
Exercise Files
N/A
Exercise Setup
N/A
Recommended Job Aids
The following job aid is recommended for use with this exercise:
Logix5000 System Glossary
Rev. September 2013
E 2013 Rockwell Automation, Inc. All rights reserved.
UN3e56r_Setup
60
Exercise Setup: Understanding Control Systems
E 2013 Rockwell Automation, Inc. All rights reserved.
Rev. September 2013
UN3e56r_Setup
Catalog Number ABT-CCP299-TIS - September 2013
Supersedes Catalog Number ABT- CCP299-TIS - January 2013
E 2013 Rockwell Automation, Inc. All rights reserved. Printed in USA