Short-Circuit Analysis Diagram

The document is a one-line diagram showing the electrical grid configuration including transmission lines, buses, transformers, and circuit breakers. It displays the short-circuit analysis results including fault currents and angles for each component. The diagram models an 11kV and 3.3kV distribution system supplying various loads through transmission lines, cables, and transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views1 page

Short-Circuit Analysis Diagram

The document is a one-line diagram showing the electrical grid configuration including transmission lines, buses, transformers, and circuit breakers. It displays the short-circuit analysis results including fault currents and angles for each component. The diagram models an 11kV and 3.3kV distribution system supplying various loads through transmission lines, cables, and transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

One-Line Diagram - OLV1 (Short-Circuit Analysis)

page 1

GRID
762.102 MVAsc

Bus1
11 kV

g
0 de
0 kV

40 kA -85.9 deg
0.448 kA -69.2 deg

CB31

CB30

Open

kA 85.7
deg

Cable -2

Cable -1
g 11 kV
0 de Bus2
0 kV
16.0
2 kA
-57.
2 de
g

40.4
3

11 kV
Bus4

15.58 kA -56.8 deg


0.456 kA -69.7 deg

OH_CKT 2

OH_CKT 1

Bus5
11 kV

Bus6
11 kV

deg
1.13 kA -51.2 deg0 kV 0
1.7
Open 7 kA -6
2.2
deg

0.692 kA -80.3 deg


Cable1

Cable2

g
0 de
0 kV

CB4

1.13 kA -51.2 deg

11 kV
Bus9
PT - 1
5 MVA

11 kV
Bus10

0.692 kA -80.3 deg

1.77
kA 62.2
deg
g
e
d
2.650 kA
-58.3 deg
kV 0

3.3 kV
Bus14

Open

CB3

PT -2
4.5 MVA
3.3 kV
Bus13

2.48 kA -79.7 deg

5.04
kA 68.6
R
deg

R
R

g
0 de
CB70 kV

Cable3

g
0 de
0 kV

Cable4

CB5

Bus11
3.3 kV

Open
1.15 kA -81 deg
3.92 kA -65.1 deg

2.65 kA -58.3 deg


0.872 kA -81.7 deg
CB8

0.282 kA -78.9 deg

0.185 kA -63.9
5. deg

04 k
A -6
8.7
deg

CB11

CB10

CB9
Open

0.872 kA -81.6 deg

CB12
Open

CB13

I>

RW -1
1380 kW

RW - 3
1380 kW

1.2
deg

AWRP - 2
440 kW

deg
V 0-59.2 deg
8.69
0 kkA
10.2
1 kA deg
1.53 kA -64.9
-60.
1 de
g

0.415 kV
Bus3

Cable15

Cable11

3.3 kV
Bus20

AUX TRF -2
0.315 MVA

deg

0
3.90 kA
deg
kV -63.5
4.74 deg
0.883 kA -82.4

3.3 kV
Bus21

kA 66.9
deg

Bus7
0.415 kV
Cable16

CB28

CB16

0.27 kA -65.6 deg


CB20

CB17
deg
V 0-67.2
7.82 kA -56.7 0.389
deg 0 kkA
8.98deg
kA -57.7
Open deg
0.389 kA -67.2 deg 0.515 kA -62.9 deg
9.36
kA 58.1
deg

CB18

Bus24 deg
0
0 kV kV
0.415
9.36

0.389 kA -67.2 deg


CB23

CB22

kA 58.1
deg

Open
CB21
CB19
LIGHT TRF -2
50 kVA

LIGHT TRF -1
50 kVA
Lump1
53 kVA
Bus27

Lump2
53 kVA

Cable14

Cable13

0.331 kA -67.2 deg

Bus28

Lump3
45 kVA

CB24

CB27

CB25
Open

Lump4
45 kVA

deg
kV 0
0 deg
2.6 kA -41.7
0.294
kA -67.2
2.87 kA
deg
-44.2 deg

Bus25
0.415 kV

0.294 kA -67.2
3. deg

14 k
CB29
A -4
6.3
deg

CB2

Lump5
40 kVA

Bus29

Lump8
40 kVA

Jul 21, 2014

Project File: MEIL - SC

3.14
kA 46.3
deg

CB33
Open

CB26

LIGHT TRF -4
50 kVA

Bus26 deg
0
0.415
0 kV kV

0.294 kA -67.2 deg

LIGHT TRF -6
50 kVA

Lump6
40 kVA

Bus31

Lump10
40 kVA

deg

V 40.27 deg
4 kA
kA
0 k-59.9

-61

3.3 kV

.2
0.284 kA -79.6 deg deBus22
g

AWRP -1
440 kW

RW - 2
1380 kW

Bus23
0.415 kV

Cable12

3.3 kV
Bus19

4.97
kA g deg
0.185 kA -63.9
0 de-67.9
deg
0 kV

deg

7.1
deg

Cable10

4.79 kA -68 deg

V 0
4 kA
deg AUX TRF -1
0 k-59.9
4.27
kA deg
MVA
0.284 kA -79.6
-0.32
6

3.3 kV
Bus17

Cable9

Cable8

deg

Cable7

Cable6

0
3.90 kA
deg 3.3 kV
kV -63.6
4.75
k-82.4
0.883 kA
Bus16
A -6 deg

I>

3.3 kV
Bus18

13:20:18

CB15
Open

Cable5

5.04
kA 68.7
deg

0.282 kA -78.9 deg


CB14

3.3 kV
Bus15

Bus12
3.3 kV

CB6

AWRP -3
440 kW

You might also like