Centrifugal Datasheet 10-11 R6

This document provides model data for a centrifugal compressor, including manufacturer, model number, number of stages, rated capacity, operating pressure, motor details, unloaded and full load power consumption, and specific power consumption. Key specifications include a rated capacity of [VALUE] acfm at a full load operating pressure of [VALUE] psig, driven by a [VALUE] hp motor rated at [VALUE] RPM and [VALUE] percent efficiency, with an unloaded power consumption of [VALUE] kW and a specific power consumption of [VALUE] kW/100cfm at rated capacity and pressure.

Uploaded by

Mouna Nj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views

Centrifugal Datasheet 10-11 R6

This document provides model data for a centrifugal compressor, including manufacturer, model number, number of stages, rated capacity, operating pressure, motor details, unloaded and full load power consumption, and specific power consumption. Key specifications include a rated capacity of [VALUE] acfm at a full load operating pressure of [VALUE] psig, driven by a [VALUE] hp motor rated at [VALUE] RPM and [VALUE] percent efficiency, with an unloaded power consumption of [VALUE] kW and a specific power consumption of [VALUE] kW/100cfm at rated capacity and pressure.

Uploaded by

Mouna Nj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

COMPRESSOR DATA SHEET

Centrifugal Compressor
MODEL DATA - FOR COMPRESSED AIR
1

Manufacturer:

Model Number:
Air Cooled

Date:

Water Cooled

# of Stages:

Packaged (mounted) Inlet Filter


Packaged (mounted) Unloading Control Valve
Packaged (mounted) Unloading Silencer
Packaged (mounted) Aftercooler
Packaged (mounted) Unit Control Panel

VALUE

UNITS

Rated Capacity at Full Load Operating Pressure a,d,e

acfma

Full Load Operating Pressure b

psigb

Drive Motor Nameplate Rating

hp

Drive Motor Nameplate Nominal Efficiency

Drive Motor Nameplate Rated Speed

8a

Fan Motor Nameplate Rating (if applicable)

8b

Fan Motor Nameplate Nominal Efficiency (if applicable)

Unloaded Power Consumption c,d

kW

10

Total Package Input Power at Rated Capacity and Full Load


Operating Pressure

kW

11

Specific Power Consumption at Rated Capacity and Full Load


Operating Pressure d,e

percent
RPM
hp
percent

kW/100 cfm

NOTES:
a.

b.
c.
d.
e.

Measured at the discharge terminal point of the compressor package. ACFM is actual cubic feet per minute at inlet conditions of;
inlet temperature of 95 F, inlet pressure of 14.5 psia, cooling water temperature of 85 F, and relative humidity of 60%. When an
inlet filter is not an integral part of the package an Inlet pressure drop of 0.2 psia shall be applied. When filter is not an integral
part of the acceptance test, a test air filter/piping system with this inlet pressure drop specification shall be mounted.
The operating pressure at which the capacity (Item 3) and electrical consumption (Item 11) were measured for this data sheet.
Tolerances are +/- 10% for unloaded power.
Guaranteed value.
Tolerances are +/- 4% for capacity and +/- 5% for specific power.
Member

Form Number CENT-060

Rev 5 5/8/09

You might also like