Equinox Test Certificate::: Particulars of Sample Analysed

This certificate summarizes the analysis of a sewage water sample collected from the Sewage Treatment Plant of Ocean Sparkle Limited in Navi Mumbai. The sample was received on January 31, 2015 and analyzed between January 31, 2015 and February 5, 2015. Key results include a pH of 7.36, electrical conductivity of 2960 mS/cm, total dissolved solids of 1924 mg/L, chemical oxygen demand of 1800 mg/L, biological oxygen demand of 550 mg/L, and oil and grease content of less than 1 mg/L. The sample was found to be intact without any leaks.

Uploaded by

alive2flirt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views1 page

Equinox Test Certificate::: Particulars of Sample Analysed

This certificate summarizes the analysis of a sewage water sample collected from the Sewage Treatment Plant of Ocean Sparkle Limited in Navi Mumbai. The sample was received on January 31, 2015 and analyzed between January 31, 2015 and February 5, 2015. Key results include a pH of 7.36, electrical conductivity of 2960 mS/cm, total dissolved solids of 1924 mg/L, chemical oxygen demand of 1800 mg/L, biological oxygen demand of 550 mg/L, and oil and grease content of less than 1 mg/L. The sample was found to be intact without any leaks.

Uploaded by

alive2flirt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

EQUINOX TEST CERTIFICATE

Reference Number

EQNX:MUM:LAB: W:15:01:1183

Document No. : IV.3.4.R

PARTICULARS OF SAMPLE ANALYSED


Client Name

: Ocean Sparkle Limited

Address

305-B, Sai Sangam Complex,


: Plot No - 85, Sector - 15, CBD Belapur, Date of Sampling
Navi Mumbai - 400 614

Contact Person
Collection Point
Sample Description
Sample Drawn By
Sample Quantity &
Condition

Sr.No.

:
:
:
:

Sampling Protocol

Mr. Sudesh
Sewage Treatment Plant.
Sewage Water
Client

: NA
: 30-Jan-15

Date of Receipt
Date of Start of Analysis
Date of End of Analysis
Date of Report

:
:
:
:

31-Jan-15
31-Jan-15
5-Feb-15
9-Feb-15

: 1 Ltr. water in a Plastic bottle is intact without any leaks.

Chemical Parameters

Units

Methods

Results of Analysis

IS:3025:Part 11:1983

7.36

pH-Value

Electrical Conductivity

mS / cm

IS:3025:Part 14:1984

2960.00

Total Dissolved Solids

mg / l

IS:3025:Part 16:1984

1924.00

Chemical Oxygen Demand

mg / l

IS:3025:Part 58:2006

1800

Biological Oxygen Demand

mg / l

IS:3025:Part 44:1993

550

Oil & Grease

mg / l

IS:3025

<1

Asst. Manager - Chemistry


(Authorised Signatory)
Mrs. S. Pradhan

Note:
1. This report is valid for the tested sample only.
2. Test report shall not be reproduced except in full & with written approval of Equinox Solutions.
3. This report should not be used for advertisement / judicial purpose.