0% found this document useful (0 votes)
48 views2 pages

1/2" Soldered and Molded Jumper Cable

This document specifies the technical details of a 1/2" soldered and molded jumper cable, including connector types, cable lengths, electrical and mechanical characteristics, jacketing options, and materials used in the connectors. The cable has a characteristic impedance of 50±1 ohms and supports frequencies up to 3000 MHz. Various length and connector configuration options are available.

Uploaded by

mickyalemu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

1/2" Soldered and Molded Jumper Cable

This document specifies the technical details of a 1/2" soldered and molded jumper cable, including connector types, cable lengths, electrical and mechanical characteristics, jacketing options, and materials used in the connectors. The cable has a characteristic impedance of 50±1 ohms and supports frequencies up to 3000 MHz. Various length and connector configuration options are available.

Uploaded by

mickyalemu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SPECIFICATION 5501/06

Replace 5502/03
14.02.2006

1/2 SOLDERED AND MOLDED JUMPER CABLE


CONNECTOR TYPE

7-16 male and female


N male and female

CABLE TYPE

RFF 1/2"-50 (Superflexible)

LENGTH

Standard lengths: 0.5, 1, 1.5, 2 and 3 m.


Other lengths available on request

ELECTRICAL CHARACTERISTICS at +20C


Characteristic impedance
Return loss (VSWR) for
- 30 - 1000 MHz
- 1000 - 2700 "
Attenuation at (cable)
- 900
MHz
- 1000

- 1800

- 1900

- 2000

- 2200

Connector attenuation (2 pcs)


Maximum operating frequency
Average power rating
- 1000
MHz
- 2200

Peak RF voltage rating


Intermodulation, typical (2x20W Tx)
- 800 - 1000 MHz
- 1600 - 2000 MHz

50 1
30 dB (1.06)
28 dB (1.08)
0.100 dB/m
0.106
0.147
0.151
0.155
0.164
0.05 dB
3000 MHz

(0.03 dB/ft)
(0.03 dB/ft)
(0.04 dB/ft)
(0.05 dB/ft)
(0.05 dB/ft)
(0.05 dB/ft)

750 W
480 W
1.39 kV
-160 dBc
-160 dBc

MECHANICAL CHARACTERISTICS
Maximum pulling force
N
DIN 7-16
Minimum bending radius
- Single bending
- Repeated bending
Operating temperature range
Crush resistance
Bending moment
Water proof

300 N
500 N
15 mm
30 mm
-55...+80C
3.4 kg/mm
2.7 Nm
IP 68

(0.6 in)
(1.2 in)
(-67...+176 F)
(190 lb/in)
(2.0 lb-ft)

JACKETING OPTIONS
JACKET
Black, halogen free LD
polyethylene
Grey, halogen free fire retardant
thermoplastic
Black, halogen free fire
retardant thermoplastic

[email protected]
Telephone +358 10 56 61
Telefax +358 10 566 4294

IEC 60754 -1/-2


halogen free,
non corrosive

IEC 61034
low smoke
emission

IEC 60332-3-24
fire retardant

UV
retardancy

Min. installation
temperature

yes

no

no

yes

-40C (-40F)

yes

yes

yes

no

-20C (-4F)

yes

yes

yes

yes

-20C (-4F)

Subject to change without prior notice.

SPECIFICATION 5501/06
Replace 5502/03
14.02.2006

LENGTH

MATERIALS IN CONNECTORS
7-16 male and N male
Outer conductor
Inner conductor
Other metallic parts
Insulation
Sealing

Copper alloy / Silver plated


Copper alloy / Silver plated
Copper alloy
PTFE
Silicon

7-16 female
Outer conductor
Inner conductor
Insulation
Sealing

Copper alloy / Silver plated


Copper alloy / Silver plated
PTFE
Silicon

N female
Outer conductor
Inner conductor
Insulation

Copper alloy / Silver plated


Copper alloy / Silver plated
PTFE

NKJ CODE KEY

NKJ

3
Code no:
Cable length:
Code no:
Connector

1
500 mm

2
1000 mm

1
2
Male 7-16 Female 7-16

3
4
1500 mm 2000 mm
3
Male N

5
6
2500 mm 3000 mm

4
Female N

NKJ Jumper Cable, e.g. NKJ126 (7-16 Male, 7-16 female, 3 m)

[email protected]
Telephone +358 10 56 61
Telefax +358 10 566 4294

Subject to change without prior notice.