4 15 September 2004
Dammam, Saudi Arabia
API 510 PREPARATORY
Points to Recall Day 5
1. For new service, or for changed service, if corrosion rate is not
known, on-stream determination after 1,000 hours shall be made
to establish or confirm corrosion rate.
2. MAWP =
/(R+0.6t)
Where t
Cn
SET
= t actual 2 x Cn
= metal loss up to next inspection
3. For corrosion area of considerable size; thickness averaging along
most critical element shall not exceed following length (l):
a.
b.
Vessel I.D. < 60. ..l = D/2 or 20 use smaller value
Vessel I.D. > 60... l = D/3 or 40 use smaller value
4. The widely scattered pits, can be ignored if:
a.
b.
c.
No pit depth in greater than half wall thickness excluding
C.A.
Total pit are does not exceed 7 square inches within 8 inch
diameter circle
Total sum along any line in circle does not exceed 2 inches
5. For surface remote from weld, (weld E < 1), shell thickness can be
recalculated with E = 1. Shell area is considered remote from
weld if it lies on either side weld beyond 1 or 2 times thickness
(whichever is greater).
6. For dished Heads, the Crown portion lies within circle concentric to
dish but crown dia. = 0.8 x shell dia.
7. For Ellipsoidal or Torispherical heads, crown portion thickness can be
recalculated considering crown as part of sphere of radius equal to
D, (for standard Torispherical) or K1 D (for Ellipsoidal).
8. For ellipsoidal head K1 depends on D/2h ratio (h=head depth) For
2:1 Ellipsoidal Head, K1 = 0.9