0% found this document useful (0 votes)
250 views2 pages

D 1.3 CWpump-DS-A-C Tce HZL Bhel

This document provides specifications for three circulating water pumps with a total 100% capacity. The pumps will have a variable speed to limit the specific speed to 6000. The pumps will be vertical, wet pit, mixed flow design and located outdoors. Materials of construction include fabricated steel, cast iron, stainless steel 410, and bronze. The pumps will undergo shop performance testing and be capable of operating from shut-off to 110% of design flow for single pump operation.

Uploaded by

Shameer Majeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
250 views2 pages

D 1.3 CWpump-DS-A-C Tce HZL Bhel

This document provides specifications for three circulating water pumps with a total 100% capacity. The pumps will have a variable speed to limit the specific speed to 6000. The pumps will be vertical, wet pit, mixed flow design and located outdoors. Materials of construction include fabricated steel, cast iron, stainless steel 410, and bronze. The pumps will undergo shop performance testing and be capable of operating from shut-off to 110% of design flow for single pump operation.

Uploaded by

Shameer Majeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

EXHIBIT A- TECHNICAL SPECIFICATION

SECTION D1.3 DS A
CWP

DATA SHEET A
CIRCULATING WATER (CW) PUMPS
Sl.No.

ITEM

UNITS

SHEET 1

OF

VALUES

Total No. of pumps

nos

: 3 x 100 % capacity

No. of pumps operating

nos

Pump capacity

m/hr

Total capacity of pumps shall be


equal to 105% of cooling water
requirement of the unit. Refer
Note 1.

Pump Total Head


excluding losses in the pump

By Contractor

Pump speed (max.)

RPM

To limit specific speed to 6000 &


ensure adequate NPSH under all
conditions

Type of pump

Vertical/wet pit/mixed flow

Location

Outdoor

Type of internal element

Non pull out

Liquid handled

Clarified water

10

Type of line bearing lubrication

Self

11

Liquid for lubrication

Pumped liquid

12

Type of pump motor coupling

Flexible`

13

Thrust bearing location

In pump and motor

14

Pump operating range

Refer Note 2

15

Motor rating

Minimum 116% of duty point


requirement and also to meet the
maximum power requirement
over the operating range at 52.5
Hz frequency.

16

Materials of construction
(a) Pump column pipe

Fab steel to IS:2062 with epoxy


painting

EXHIBIT A- TECHNICAL SPECIFICATION

SECTION D1.3 DS A
CWP

DATA SHEET A
CIRCULATING WATER (CW) PUMPS
Sl.No.

17

ITEM

UNITS

SHEET 2

OF

VALUES

(b) Pump bowl and discharge


elbow

CI to IS:210 FG 260

(c) Impeller

SS 410/Bronze

(d) Shaft

SS 410

(e) Line shaft coupling

SS 410

(f) Line shaft bearing

Cutlass rubber in SS shell

(g) All hardware under water

SS 304

(h) Sole plate

MS to IS 2062

(i) Base plate

CI/MS

(j) Shaft sleeve

SS

(k) Thrust bearing cooling system


pipes and valves

SS

Shop performance test

To be conducted on all pumps

Notes :
1) By cooling water requirement it is meant sum of condenser cooling water flow and flow in the
auxiliary cooling water circuit.
2) Pumps shall be capable of operating from shut-off point to a maximum flow of 10% over the
point intersection between system resistance curve and pump H-Q curve for single pump
operation
3) The CW Pump & Motor shall be capable of reverse rotation due to back flow of water during
pump
tripping for a short period.
4) Channel design shall be as per HIS or BHRA standard