Overall Heat Transfer Coefficient of Reactor

The document discusses calculating heat transfer coefficients for an agitated vessel with a jacketed coil. It provides data on the vessel, jacket, fluids, and agitator and calculates the overall heat transfer coefficient and power requirements based on established equations.

Uploaded by

instrutech
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
133 views7 pages

Overall Heat Transfer Coefficient of Reactor

The document discusses calculating heat transfer coefficients for an agitated vessel with a jacketed coil. It provides data on the vessel, jacket, fluids, and agitator and calculates the overall heat transfer coefficient and power requirements based on established equations.

Uploaded by

instrutech
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

Overall Heat Transfer Coefficient of reactor

For any comments, feed back & suggestions mail us at

[email protected]

Revision No
1
Issued to download section 27.05.12

chemjunction.com
Calculation of heat transfer coefficients in agitated vessels:
Cooling with water:

Data:
Vessel data:
Material of construction:
Inner diameter of the vessel, Dv :
Wall thickness of vessel,t :
Thermal conductivity of SS316 =

SS316
2450
2.45
10
0.01
9.4
13.9872

mm
m
mm
m
Btu/ft.h.F
Kcal/h m K

[STD. GCL 15.7 KL Reactor]

Dirt resistance :Inside vessel, Rdi :

0.0006 h ft2 F/Btu


0.000123 h m2 K/Kcal

Jacket side [water], Rdj :

0.0013 h ft2 F/Btu


0.000266 h m2 K/Kcal

Jacket data:
Type:
Coil Diameter, Dc :
Inner pipe diameter, di :
Equi. Diameter, De= di/2 :

Limpet (Half-pipe coil type)


2650
2.65
82
0.082

mm
m
mm
m

0.128857 m

Medium:
Temparature:

Water
35 C

Flow rate:

18 m3/Hr

Flow area:
Velocity, v:
Density, :
Viscosity, :
Thermal conductivity, k :

Specific heat, C :

Vessel fluid data:


Name of the fluid :
Temparature:
Density, :
Viscosity, :

0.002642 m2
1.89 m/s
1 g/cm3
1000
1.000
0.001
0.363
0.540
0.00015
1

Kg/m3
cp
Pa.s
Btu/ft.h.F
Kcal/h m K
Kcal/s m K
Kcal/Kg K

MCB
75 C

1.08 g/cm3

1080 Kg/m3
0.445 cp
0.000445 Pa.s

Temp C
10

0.0476
0.0709
2.0E-005
0.35

Thermal conductivity, k :

Specific heat, C :
Agitator data:
Type :
Sweep
Diameter, Da :
Speed, N
Tip speed :

Btu/ft.h.F
Kcal/h m K
Kcal/s m K
Kcal/Kg K

[Perry]

75

Pitch-blade turbine
40 %
980 mm
0.98 m
70 rpm
1.17 rps
3.59 m/s

Heat transfer coefficients:


Vessel side heat transfer coefficient:
For Agitated vessels without internal coils:
Nu = 0.62 Re(2/3) Pr(1/3) (/ w)0.14
Ref: Chopey, pg.7-28)
Nu = h Dv / k
Re = D N /
2
a

24071
2719404

Pr = C / k

Heat transfer co-efficient inside the reactor =

7.9

696 Kcal/h m2 K

Heat transfer coefficient inside limpets (Half-pipe coil jacket):


For half-pipe coil jacket:
Nu = 0.027Re0.8 Pr0.33 (/ w)0.14(1+3.5De/Dc)
(Ref:Chem.engg.,90,vol.106,1,1999)
Nu = h De / k

1206

Re = Dev /

243902

Pr = C / k

6.7

Heat transfer co-efficient, hj =

5054.117 Kcal/h m2 K

Wall Resistance, Rw : l/k

0.000715 h m2 K/Kcal
1398.72 Kcal/h m2 K

Heat transfer co-efficient inside the reactor(hi) :


Jacket side heat transfer co-efficient (hj) :
Wall resistance (Rw) :
Total dirt factor (Rd) :
(Overall heat transfer coefficient)-1 :
Overall heat transfer coefficient (Ud) :

696
5054
0.00071494
0.00038924

Kcal/h m2 K
Kcal/(Hr*m*C)
(Hr*m*K)/ Kcal
(Hr*m*K)/ Kcal
0.00273855 (Hr*m*K)/ Kcal
365 Kcal/(Hr*m*C)

Power Requirement:
Agitator details
Pitch-blade turbine(45)
Anchor

FHP :
BHP :

5581 W
7.48 HP
8.80 HP

Np

No.
1.5
0.6

Total
2
1

3
0.6
3.6

GCL 15.7 KL Reactor]

-1.707012
471.8691

Temp C

cp
75 0.444988619

cp
C Kcal/Kg K k Btu/ft.h.F
0.911
0.298
0.083

0.445

0.35 0.047616821