Connect as below:
Serial Suite:
Red
Black
ECU Plug:
to
to
1 Pins Red (Power Supply +12 Volt)
1 Pins Black (Ground)
Piasiniengineering [email protected] http://www.piasiniengineering.it
Tel: +39 0342 489060 - Fax: +39 0342 488298
Where to connect the flat cable:
Backside:
Piasiniengineering [email protected] http://www.piasiniengineering.it
Tel: +39 0342 489060 - Fax: +39 0342 488298
READ the ECU:
For read the ECU connect the flat cable following the red number in the picture.
Piasiniengineering [email protected] http://www.piasiniengineering.it
Tel: +39 0342 489060 - Fax: +39 0342 488298
WRITE the ECU:
Front:
For write the ECU put 1 capacitor(1uF) and connect the flat cable following the
number in the picture.
Back:
For write the ECU put 1 wire(bridge) and connect the flat cable following the number
in the picture.
Piasiniengineering [email protected] http://www.piasiniengineering.it
Tel: +39 0342 489060 - Fax: +39 0342 488298