Are you looking for
the maximum return
on your investment
in wind energy?
Wind energy means the world to us. And we want it to mean the
world to our customers, too, by maximising your profits and
strengthening the certainty of your investment in wind power.
Thats why, together with our partners, we always strive to deliver
cost-effective wind technologies, high quality products and first
class services throughout the entire value chain. And its why
we put so much emphasis on the reliability, consistency and
predictability of our technology.
These arent idle words. We have over 30 years experience in
wind energy. During that time, weve delivered more than 62 GW
of installed capacity and we currently monitor over 25,000 wind
turbines across the globe. Tangible proof that Vestas is the right
partner to help you realise the full potential of your wind site.
What is the 2 MW platform?
Our 2 MW platform provides industry-leading reliability,
serviceability and availability. Durable and dependable, the
platform is built on technology that has been proven in the
field over more than a decade. The 2 MW platform reduces
your costs, minimises the risk of turbine downtime and helps
to safeguard your investment.
You can choose from four turbines on the 2 MW platform:
V110-2.0 MW IEC IIIA
V100-2.0 MW IEC IIB
V100-1.8/2.0 MW IEC IIIA/IEC S
V90-1.8/2.0 MW IEC IIA/IEC IIIA
Each 2 MW turbine incorporates enhancements that improve
performance and reliability, reducing your cost of energy. The
platforms predictability allows you to forecast confidently,
strengthening the business case for investment, while the
tried-and-tested design ensures you can produce energy
on low, medium and high-wind onshore sites at the lowest
possible cost, even in extreme weather conditions. In addition,
remote monitoring and easy servicing keep operational costs
at a minimum, while its highly-tested components and power
and control systems enhance reliability.
+13,000
Due to the strong performance and
reliability of the 2 MW platform,
over 13,000 turbines have been
installed since 2002.
How does the 2MW
platform increase
reliability and
performance?
Created with future generations of turbines in mind, the 2 MW
platforms single-piece bed frame and stronger main bearing
housing provide a better foundation for loads. The toughened
frame and housing each made from single-piece castings
work in conjunction to absorb higher loads from the rotor.
Additionally, the housing ensures correct alignment during
bearing assembly, making the process more accurate and efficient
and distributing loads evenly. These improvements combine to
increase production capabilities and reduce downtime.
A reliable performer
The 2 MW platform is an extremely reliable turbine, which is
documented through its strong availability performance.
With the newest addition of rotor size, the 2 MW platform offers
a competitive selection of turbines for all wind segments.
Thoroughly tested
The current 2 MW platform is built on unique knowledge from
more than a decade of operational experience. We constantly
monitor the majority of the installed 2 MW turbines, providing
us with very detailed and invaluable information about how the
turbine operates under all kinds of site conditions.
Our quality-control system ensures that each component is
produced to design specifications and performs to peak potential at site. We also employ a Six Sigma philosophy and have
identified critical manufacturing processes (both in-house and
for suppliers). We systematically monitor measurement trends
that are critical to quality, locating defects before they occur.
Innovative CoolerTop
Our exclusive CoolerTop technology uses the wind's own energy
to generate the cooling required, rather than consuming energy
from the wind turbine generator. CoolerTop has no moving parts
and requires little maintenance. Furthermore, the absence of
cooling fans contributes to turbine efficiency and makes no noise.
Load and Power Modes increase energy output
The 2 MW platform supports Load and Power Modes, used to
maximise energy production under specific wind and site conditions. Based on a site analysis, turbines can be configured to run
derated when wind conditions require it. Conversely, under mild
wind conditions, the turbine can be uprated - maximising annual
energy production.
The 2 MW platform covers all wind segments enabling you
to find the best turbine for your specific site.
WINDCLASSES - IEC
TURBINE TYPE
IEC III (6.0 7.5 m/s)
IEC II (7.5 8.5 m/s)
IEC I (8.5 10.0 m/s)
2 MW TURBINES
V110-2.0 MW IEC IIIA
V100-2.0 MW IEC IIB
V100-1.8/2.0 MW IEC IIIA/IEC S
V90-1.8/2.0 MW IEC IIA/ IEC IIIA
Standard IEC conditions Site dependent
Low Balance of Plant, installation and transportation costs
At Vestas, we use technology tailored to control loads on specific
tower heights. We have applied this principle to the 2 MW platform
by reducing both the weight of the turbine and the loads on the
tower and foundation. This reduces foundation costs, saving you
unnecessary expense.
All 2MW turbines are easy to transport (by rail, truck or ship) to
virtually any site around the world. In terms of weight, height and
width, all components comply with local and international standard transportation limits, ensuring you incur no unforeseen costs.
In addition, 2MW turbines are built and maintained using tools
and equipment that are standard in the installation and servicing
industries minimising maintenance costs.
24/7 remote surveillance with VMP Global and
Vestas Online Business
To reduce the cost of energy, the 2 MW platform is equipped with
VMP Global, our latest turbine control and operation software.
Developed to run this latest generation of turbines, VMP Global,
combined with Vestas Online Business, automatically manages
the turbine 24/7 and ensures maximum power generation. The
application also monitors and troubleshoots the turbines both
onsite and remotely saving further expense on servicing.
Designed for serviceability
Service is facilitated by the overall design of the 2 MW platform
and components are specifically positioned for easy access.
Vestas Online Business
Options available for the 2 MW platform
All Vestas wind turbines benefit from Vestas Online Business,
the latest Supervisory Control and Data Acquisition (SCADA)
system for modern wind power plants. This flexible system
includes an extensive range of monitoring and management
functions to control your wind power plant in the same way as a
conventional power plant. Vestas Online Business enables you
to optimise production levels, monitor performance, and produce
detailed, tailored reports from anywhere in the world. The systems
power plant controller provides active and reactive power regulation, power ramping and voltage control.
Yaw power backup
Increased cut-in
Shadow detection
Obstacle Collision Avoidance System (OCAS)
Smoke detection
Aviation marking
Load and power modes
Would you benefit
from uninterrupted
control of wind energy
production?
Knowledge about wind project planning is key
Getting your wind energy project up and operating as quickly as
possible is fundamental to its long-term success. One of the first
and most important steps is to identify the most suitable location
for your wind power plant. Vestas' SiteHunt is an advanced analytical tool that examines a broad spectrum of wind and weather
data to evaluate potential sites and establish which of them can
provide optimum conditions for your project.
In addition, SiteDesign optimises the layout of your wind power
plant. SiteDesign runs Computational Fluid Dynamics (CFD)
software on our powerful in-house supercomputer Firestorm to
perform simulations of the conditions on site and analyse their
effects over the whole operating life of the plant. Put simply, it
finds the optimal balance between the estimated ratio of annual
revenue to operating costs over the lifetime of your plant, to
determine your projects true potential and provide a firm basis
for your investment decision.
The complexity and specific requirements of grid connections
vary considerably across the globe, making the optimal design
of electrical components for your wind power plant essential. By
identifying grid codes early in the project phase and simulating
extreme operating conditions, Electrical PreDesign provides you
with an ideal way to build a grid compliant, productive and highly
profitable wind power plant. It allows customised collector network
cabling, substation protection and reactive power compensation,
which boost the cost efficiency of your business.
Advanced monitoring and real-time plant control
All our wind turbines can benefit from VestasOnline Business,
the latest Supervisory Control and Data Acquisition (SCADA)
system for modern wind power plants.
This flexible system includes an extensive range of monitoring
and management functions to control your wind power plant.
VestasOnline Business enables you to optimise production levels,
+25,000
The Vestas Performance and
Diagnostics Centre monitors more
than 25,000 turbines worldwide.
We use this information to continually develop and improve our
products and services.
monitor performance and produce detailed, tailored reports from
anywhere in the world. The VestasOnline Power Plant Controller
offers scalability and fast, reliable real-time control and features
customisable configuration, allowing you to implement any control
concept needed to meet local grid requirements.
Surveillance, maintenance and service
Operating a large wind power plant calls for efficient management strategies to ensure uninterrupted power production and
to control operational expenses. We offer 24/7 monitoring,
performance reporting and predictive maintenance systems to
improve turbine performance and availability. Predicting faults in
advance is essential, helping to avoid costly emergency repairs
and unscheduled interruptions to energy production.
Our Condition Monitoring System (CMS) assesses the status
of the turbines by analysing vibration signals. For example, by
measuring the vibration of the drive train, it can detect faults at
an early stage and monitor any damage. This information allows
pre-emptive maintenance to be carried out before the component fails, reducing repair costs and production loss.
Additionally, our Active Output Management (AOM) concept
provides detailed plans and long term agreements for service
and maintenance, online monitoring, optimisation and troubleshooting. It is possible to get a full scope contract, combining
your turbines state-of-the-art technology with guaranteed
time or energy-based availability performance targets, thereby
creating a solid base for your power plant investment. The Active
Output Management agreement provides you with long term
and financial operational peace of mind for your business case.
V110-2.0 MW
Facts & figures
POWER REGULATION
Pitch regulated with
variable speed
OPERATING DATA
Rated power
Cut-in wind speed
Rated wind speed
Cut-out wind speed
Wind class
Operating temperature range:
2,000 kW (50/60 Hz)
3 m/s
11.5 m/s
20 m/s
IEC IIIA
standard turbine:
-20C to 40C.
low temperature turbine:
-30C to 40C
SOUND POWER
Max 107.5 dB*
(Mode 0, 10 m above ground,
hub height 80 m, air density 1.225 kg/m)
tubular steel tower
95 m and 125 m (50 Hz)
80 m and 95 m (60 Hz)
* Tower heights are preliminary and subject to change
NACELLE DIMENSIONS
Height for transport
Height installed
(incl. CoolerTop)
Length
Width
4m
5.4 m
10.4 m
3.5 m
HUB DIMENSIONS
Max. transport height
Max. transport width
Max. transport length
3.4 m
4m
4.2 m
Max. weight per unit for
transportation
* for further information on noise limits please contact Vestas
ROTOR
Rotor diameter
Swept area
Air brake
TOWER
Type
Hub heights*
110 m
9,503 m
full blade feathering with
3 pitch cylinders
70 metric tonnes
ANNUAL ENERGY PRODUCTION
MWh
10.000
9.000
ELECTRICAL
Frequency
Generator type
8.000
7.000
50/60 Hz
4-pole (50 Hz)/6-pole (60 Hz)
doubly fed generator, slip rings
6.000
5.000
4.000
3.000
2.000
GEARBOX
Type
BLADE DIMENSIONS
Length
Max. chord
V110-2.0 MW IEC IIIA
1.000
two helical stages and
one planetary stage
54 m
3.9 m
0
6.0
6.5
7.0
7.5
8.0
8.5
Yearly average wind speed m/s
Assumptions
One wind turbine, 100% availability, 0% losses, k factor =2,
Standard air density = 1.225, wind speed at hub height
POWER CURVE FOR V110-2.0 MW
Noise reduced sound power modes are available
2,200
2,000
1,800
1,600
Output (kW)
1,400
1,200
1,000
800
600
400
200
0
0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Wind speed (m/s)
V110-2.0 MW FEATURES
V110-2.0 MW OPTIONS
V
estas OptiStop pitch
control strategy included to
reduce loads and enable a
lighter structure
Select products from the
Vestas PowerPlus range
are added to maximise
output
Yaw Power Backup
Increased Cut-In
Shadow detection
OCAS
Smoke detection
Aviation marking
Load mode
29
30
V100-2.0 MW
Facts & figures
POWER REGULATION
Pitch regulated with
variable speed
OPERATING DATA
Rated power
Cut-in wind speed
Rated wind speed
Cut-out wind speed
Wind class
Operating temperature range:
2,000 kW (50/60 Hz*)
3 m/s
12 m/s
22 m/s
IEC IIB
standard turbine:
-20C to 40C.
low temperature turbine:
-30C to 40C
* The rated power for V100 IEC IIIA 60 Hz is limited to 1950 kW in North America
SOUND POWER
TOWER
Type
Hub heights
tubular steel tower
80 m, 95 m and 120 m (IEC IIB)
NACELLE DIMENSIONS
Height for transport
Height installed
(incl. CoolerTop)
Length
Width
4m
5.4 m
10.4 m
3.5 m
HUB DIMENSIONS
Max. transport height
Max. transport width
Max. transport length
3.4 m
4m
4.2 m
Max 105 dB*
Max. weight per unit for
transportation
(Mode 0, 10 m above ground,
hub height 80 m, air density 1.225 kg/m)
70 metric tonnes
* for further information on noise limits please contact Vestas
ANNUAL ENERGY PRODUCTION
ROTOR
Rotor diameter
Swept area
Air brake
100 m
7,854 m
full blade feathering with
3 pitch cylinders
MWh
10.000
9.000
8.000
7.000
ELECTRICAL
Frequency
Generator type
GEARBOX
Type
BLADE DIMENSIONS
Length
Max. chord
6.000
50/60 Hz
4-pole (50 Hz)/6-pole (60 Hz)
doubly fed generator, slip rings
5.000
4.000
3.000
2.000
V100-2.0 MW IEC IIB
1.000
0
two helical stages and
one planetary stage
49 m
3.9 m
6.0
6.5
7.0
7.5
8.0
8.5
Yearly average wind speed m/s
Assumptions
One wind turbine, 100% availability, 0% losses, k factor =2,
Standard air density = 1.225, wind speed at hub height
POWER CURVE FOR V100-2.0 MW (50/60 Hz)
Noise reduced sound power modes are available
2,200
2,000
1,800
1,600
Output (kW)
1,400
1,200
1,000
800
600
400
200
0
0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Wind speed (m/s)
V100-2.0 MW FEATURES
V
estas OptiStop pitch
control strategy included to
reduce loads and enable a
lighter structure
Select products from the
Vestas PowerPlus range
are added to maximise
output
V100-2.0 MW OPTIONS
Yaw Power Backup
Increased Cut-In
Shadow detection
OCAS
Smoke detection
Aviation marking
Load mode
29
30
V100-1.8/2.0 MW
Facts & figures
POWER REGULATION
Pitch regulated with
variable speed
OPERATING DATA
Rated power
Cut-in wind speed
Rated wind speed
Cut-out wind speed
Wind class
1,800/2,000 kW (50/60 Hz*)
3 m/s
12 m/s
20 m/s
IEC S (IEC IIIA average wind/
IEC IIA extreme wind)
standard turbine:
-20C to 40C.
low temperature turbine:
-30C to 40C
Operating temperature range:
* The rated power for V100 IEC IIIA 60 Hz is limited to 1950 kW in North America
TOWER
Type
Hub heights
tubular steel tower
80 m, 95 m and 120 m (IEC IIIA)
NACELLE DIMENSIONS
Height for transport
Height installed
(incl. CoolerTop)
Length
Width
4m
5.4 m
10.4 m
3.5 m
HUB DIMENSIONS
Max. transport height
Max. transport width
Max. transport length
3.4 m
4m
4.2 m
SOUND POWER
Max 105 dB*
(Mode 0, 10 m above ground,
hub height 80 m, air density 1.225 kg/m)
Max. weight per unit for
transportation
70 metric tonnes
* for further information on noise limits please contact Vestas
ANNUAL ENERGY PRODUCTION
ROTOR
Rotor diameter
Swept area
Air brake
10.000
100 m
7,854 m
full blade feathering with
3 pitch cylinders
MWh
9.000
8.000
7.000
6.000
ELECTRICAL
Frequency
Generator type
5.000
50/60 Hz
4-pole (50 Hz)/6-pole (60 Hz)
doubly fed generator, slip rings
4.000
3.000
2.000
V100-1.8 MW IEC IIIA
V100-2.0 MW IEC IIB
1.000
0
GEARBOX
Type
BLADE DIMENSIONS
Length
Max. chord
6.0
two helical stages and
one planetary stage
49 m
3.9 m
6.5
7.0
7.5
8.0
8.5
Yearly average wind speed m/s
Assumptions
One wind turbine, 100% availability, 0% losses, k factor =2,
Standard air density = 1.225, wind speed at hub height
POWER CURVE FOR V100-1.8/2.0 MW (50/60 Hz)
Noise reduced sound power modes are available
2,200
2,000
1,800
1,600
Output (kW)
1,400
1,200
1,000
800
600
400
200
0
0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Wind speed (m/s)
V100-1.8/2.0 MW OPTIONS
Yaw Power Backup
Increased Cut-In
Shadow detection
OCAS
Smoke detection
Aviation marking
Load and power modes
30
V90-1.8/2.0 MW
Facts & figures
POWER REGULATION
Pitch regulated with
variable speed
OPERATING DATA
Rated power
IEC IIA - 50 Hz: 1,800 kW
IEC IIA - 60 Hz: 1,815 kW
IEC IIIA - 50 Hz: 2,000 kW
4 m/s
12 m/s
25 m/s
IEC IIA (V90-1.8 MW)
IEC IIIA (V90-2.0 MW)
Cut-in wind speed
Rated wind speed
Cut-out wind speed
Wind class
Operating temperature range:
standard turbine: -20C to 40C.
low temperature turbine: -30C to 40C
SOUND POWER
Max 104 dB*
(Mode 0, 10 m above ground,
hub height 80 m, air density 1.225 kg/m)
* for further information on noise limits please contact Vestas
ROTOR
Rotor diameter
Swept area
Air brake
TOWER
Type
Hub heights
V90-1.8 MW - 50 Hz
V90-1.8 MW - 60 Hz
V90-2.0 MW
tubular steel tower
80 m, 95 m and 105 m (IEC IIA)
80 m and 95 m (IEC IIA)
80 m, 95 m, 105 m and 125 m (IEC IIIA)
95 m, 105 m, and 125 m (DIBt2)
NACELLE DIMENSIONS
Height for transport
Height installed
(incl. CoolerTop)
Length
Width
4m
5.4 m
10.4 m
3.5 m
HUB DIMENSIONS
Max. transport height
Max. transport width
Max. transport length
3.4 m
4m
4.2 m
Max. weight per unit for
transportation
90 m
6,362 m
full blade feathering with
3 pitch cylinders
70 metric tonnes
ANNUAL ENERGY PRODUCTION
MWh
10.000
ELECTRICAL
Frequency
Generator type
Nominal output
9.000
50/60 Hz
4-pole (50 Hz)/6-pole (60 Hz)
doubly fed generator, slip rings
50 Hz: 1,800 kW/2,000 kW
60 Hz: 1,815 kW
8.000
7.000
6.000
5.000
4.000
3.000
2.000
V90-1.8 MW IEC IIA
V90-2.0 MW IEC IIIA
1.000
GEARBOX
Type
BLADE DIMENSIONS
Length
Max. chord
two helical stages and one
planetary stage
44 m
3.5 m
6.0
6.5
7.0
7.5
8.0
8.5
Yearly average wind speed m/s
Assumptions
One wind turbine, 100% availability, 0% losses, k factor =2,
Standard air density = 1.225, wind speed at hub height
POWER CURVE FOR V90-1.8/2.0 MW (50/60 Hz)
Noise reduced sound power modes are available
2,200
2,000
1,800
1,600
Output (kW)
1,400
1,200
1,000
800
600
400
200
0
0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Wind speed (m/s)
V90-1.8/2.0 MW OPTIONS
Yaw Power Backup
Increased Cut-In
Shadow detection
OCAS
Smoke detection
Aviation marking
Load and power modes
30
2014 Vestas Wind Systems A/S. All rights reserved.
This document was created by Vestas Wind Systems A/S on behalf of the Vestas Group and contains copyrighted material, trademarks and other proprietary information. This document or parts
thereof may not be reproduced, altered or copied in any form or by any means without the prior written permission of Vestas Wind Systems A/S. All specifications are for information only and are
subject to change without notice. Vestas Wind Systems A/S does not make any representations or extend any warranties, expressed or implied, as to the adequacy or accuracy of this information.
This document may exist in multiple language versions. In case of inconsistencies between language versions the English version shall prevail. Certain technical options, services and wind turbine
models may not be available in all locations/countries.
09/2014-EN
Vestas Wind Systems A/S
Hedeager 44 . 8200 Aarhus N . Denmark
Tel: +45 9730 0000 . Fax: +45 9730 0001
[email protected] . vestas.com