drilling systems
Cameron FLEXPACKER-NR
7-1/16- 10,000 psi U Type Blowout Preventers
Purpose
To provide information on recent qualification test
results and availability of a previously developed
FLEXPACKER-NR packer for the 7-1/16-10,000 psi
Cameron U BOP.
Qualification Requirement
API 16A 2nd Edition, Appendix B, Fatigue Test
Field Test Conditions
BOP Used
Cameron 7-1/16-10,000 psi U BOP
Test Fluid
Water
Test Temperatures
Approximately 75 F
Test Pressure
10,000 psi
BOP Operating Pressure
1500 psi
Test Procedure
tests were conducted on the smallest size pipe in the
API 16A 2nd Edition, Appendix B, Fatigue test -
packer range and the other half were conducted on
546 closures including 78 rated pressure test on the
the largest size pipe in the packer range.
smallest and largest pipe sizes in the packer specified
	 FLEXPACKER-NR packers are designed to fit into
range. Qualification testing completed in September
and October 2004.
Results
FLEXPACKER-NR in pipe size ranges 1-1/2 x 2-3/8,
2-3/8 x 2-7/8, and 2-7/8 x 3-1/2 successfully completed API 16A, 2nd Edition, Appendix B Fatigue
Test (546 closures and 78 pressure tests) at ambient
temperature. One half of the pressure and closure
standard fixed bore rams.
	 1-1/2 x 2-3/8 FLEXPACKER-NR fits into a standard
2-3/8 fixed bore ram P/N 644501-06
	 2-3/8 x 2-7/8 FLEXPACKER-NR fits into a standard
2-7/8 fixed bore ram P/N 644501-07
	 2-7/8 x 3-1/2 FLEXPACKER-NR fits into a standard
3-1/2 fixed bore ram P/N 644502-01-00-01
drilling systems
Applicable Part Numbers
BOP Size
Pressure Rating
DESCRIPTION
PART NUMBER
USE WITH RAM P/N
7-1/16
10,000 psi
FLEXPACKER-NR 1-1/2 x 2-3/8
2232367-01
644501-06
7-1/16
10,000 psi
FLEXPACKER-NR 2-3/8 x 2-7/8
2232367-02
644501-07
7-1/16
10,000 psi
FLEXPACKER-NR 2-7/8 x 3-1/2
2232367-03
644502-01-00-01
Notes:
1. FLEXPACKER-NR packers are molded using CAMLAST
elastomer. This elastomer compound has been successfully
tested for extended periods of time in the 13-5/8-10,000
psi FLEXPACKER-NR at 200 F. This CAMLAST elastomer
compound has also been exposed to H2S levels up to 35%
in drilling applications without failure.
2. Test results of the 7-1/16 FLEXPACKER-NR at 10,000 psi
are available. Contact your Cameron representative.
29501 Katy Freeway, Katy, TX 77494, Tel: 281.391.4600, Fax: 281.391.4640, www.c-a-m.com
 2008 Cameron | FLEXPACKER, U BOP and CAMLAST are trademarks of Cameron International Corporation | CAMERON is a registered trademark
of Cameron International Corporation | 09/08, TC9609 E-27