100% found this document useful (1 vote)
213 views2 pages

Cameron Flexpacker NR 7 116

This document provides information on qualification test results and availability of a previously developed FLEXPACKER-NR packer for the 7-1/16”-10,000 psi Cameron UTM BOP. It details the qualification requirements, field test conditions, test procedures, results, applicable part numbers and notes.

Uploaded by

Ryan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
213 views2 pages

Cameron Flexpacker NR 7 116

This document provides information on qualification test results and availability of a previously developed FLEXPACKER-NR packer for the 7-1/16”-10,000 psi Cameron UTM BOP. It details the qualification requirements, field test conditions, test procedures, results, applicable part numbers and notes.

Uploaded by

Ryan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

drilling systems

Cameron FLEXPACKER-NR
7-1/16- 10,000 psi U Type Blowout Preventers

Purpose
To provide information on recent qualification test
results and availability of a previously developed
FLEXPACKER-NR packer for the 7-1/16-10,000 psi
Cameron U BOP.

Qualification Requirement
API 16A 2nd Edition, Appendix B, Fatigue Test

Field Test Conditions


BOP Used

Cameron 7-1/16-10,000 psi U BOP

Test Fluid

Water

Test Temperatures

Approximately 75 F

Test Pressure

10,000 psi

BOP Operating Pressure

1500 psi

Test Procedure

tests were conducted on the smallest size pipe in the

API 16A 2nd Edition, Appendix B, Fatigue test -

packer range and the other half were conducted on

546 closures including 78 rated pressure test on the

the largest size pipe in the packer range.

smallest and largest pipe sizes in the packer specified

FLEXPACKER-NR packers are designed to fit into

range. Qualification testing completed in September


and October 2004.

Results
FLEXPACKER-NR in pipe size ranges 1-1/2 x 2-3/8,
2-3/8 x 2-7/8, and 2-7/8 x 3-1/2 successfully completed API 16A, 2nd Edition, Appendix B Fatigue
Test (546 closures and 78 pressure tests) at ambient
temperature. One half of the pressure and closure

standard fixed bore rams.


1-1/2 x 2-3/8 FLEXPACKER-NR fits into a standard
2-3/8 fixed bore ram P/N 644501-06
2-3/8 x 2-7/8 FLEXPACKER-NR fits into a standard
2-7/8 fixed bore ram P/N 644501-07
2-7/8 x 3-1/2 FLEXPACKER-NR fits into a standard
3-1/2 fixed bore ram P/N 644502-01-00-01

drilling systems

Applicable Part Numbers


BOP Size

Pressure Rating

DESCRIPTION

PART NUMBER

USE WITH RAM P/N

7-1/16

10,000 psi

FLEXPACKER-NR 1-1/2 x 2-3/8

2232367-01

644501-06

7-1/16

10,000 psi

FLEXPACKER-NR 2-3/8 x 2-7/8

2232367-02

644501-07

7-1/16

10,000 psi

FLEXPACKER-NR 2-7/8 x 3-1/2

2232367-03

644502-01-00-01

Notes:
1. FLEXPACKER-NR packers are molded using CAMLAST
elastomer. This elastomer compound has been successfully
tested for extended periods of time in the 13-5/8-10,000
psi FLEXPACKER-NR at 200 F. This CAMLAST elastomer
compound has also been exposed to H2S levels up to 35%
in drilling applications without failure.
2. Test results of the 7-1/16 FLEXPACKER-NR at 10,000 psi
are available. Contact your Cameron representative.

29501 Katy Freeway, Katy, TX 77494, Tel: 281.391.4600, Fax: 281.391.4640, www.c-a-m.com