0% found this document useful (0 votes)
126 views12 pages

Br05-Box Load Per Pile

This document provides calculations for loads on a railway bridge pier including: 1) Superimposed dead loads from sleepers and ballast totaling 28.14 kN/m. 2) Lateral earth pressure and superimposed dead load pressure of 20.98 kN/m^2 at the base increasing to 61.48 kN/m^2 at a depth of 6.75m. 3) Live load pressure of 11.60 kN/m^2 from passing trains.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views12 pages

Br05-Box Load Per Pile

This document provides calculations for loads on a railway bridge pier including: 1) Superimposed dead loads from sleepers and ballast totaling 28.14 kN/m. 2) Lateral earth pressure and superimposed dead load pressure of 20.98 kN/m^2 at the base increasing to 61.48 kN/m^2 at a depth of 6.75m. 3) Live load pressure of 11.60 kN/m^2 from passing trains.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 12

Dead Load Per Pile Under Box Portion

Super Imposed Dead Load From Sleeper


Number of sleeper in broad gauge track (N+7) =
Number of sleeper over the box portion =
Length over which sleeper will be distributed =
Weight Calculation of Concrete Sleeper
Section of Sleeper

20
30
19.4 m

(Book: Railway Track Engineering by J.S. Mundrey, p-108)


2750mm

154mm
154mm
210mm
180mm

250mm
Weight of each sleeper =
UDL due to sleeper =

220mm
2.748975 kN
4.250992 kN/m

Weight Calculation of Ballast


2750 mm

6850 mm
Unit weight of ballast =
UDL due to ballast =

1650 kg/m
23.29906 kN/m

(width of top slab measured from CA

UDL due to rail track =

Total Super Imposed Dead load =

60 kg/m =

0.58836 kN/m

28.13841 kN/m

(N=13 for B.G. track)


(measured from CAD drawing)

drey, p-108)

p slab measured from CAD)

300 mm

Lateral Pressure Due to Earth and Super


Imposed Dead Load
Angle of repose of the soil, =
30 degree
Coefficient of earth pressure, Ka =
Lateral pressure due to earth =
6h
Lateral pressure due to SDL =
9.379469 kN/m
Total lateral pressure at "h" due to SDL and Earth=

(1-sin)/(1+sin)

9.379469 +

(1-sin)/(1+sin)

Live Load Calculation (Adapted from STAAD)


Axle load =
Train Load =

22.5 ton
80.9 kN/m

IRC standards followed

tandards followed

Lateral Pressure Due to Live Load


Assuming 1 meter strip =
34.79381 kN/m
Lateral Pressure due to live load =
11.59794 kN/m2

Total Lateral Pressure Due to (Live Load+SDL+Earth)


at h=0;
total lateral pressure =
at h =
6.75 m
total lateral pressure =

20.97741 kN/m
(measured from CAD)
61.47741 kN/m

20.97741 +

Thickness of each side wall =


Weight of each side wall =
Thickness of interior wall =
Weight of interior wall =
Thickness of top slab =
Weight of top slab =
Upward soil reaction at base =

600 mm
101.25 kN/m
400 mm
67.5 kN/m
600 mm
15 kN/m
67.19072 kN/m