Precision Cooling for
Business-Critical Continuity
Liebert HPM from 4 kW to 100 kW
Efficient Direct Expansion Cooling for Data Centers
410A
R
h
t
i
W
rant
e
g
i
r
f
e
R
Whether a
data center
houses three
or 200 IT racks,
deployment of
new technologies
with high power
densities are
impacting
the power
and cooling
systems that
business-critical
servers and
communications
devices depend
on for their
performance and
reliability.
The critical infrastructure
systems from Emerson
Network Power allow
customers to respond to
changes in density, capacity
and availability while achieving
greater operating flexibility,
higher system availability and
lower total costs of ownership.
Emerson Network Power
delivers innovative solutions
through 12 Centers of
Expertise, distinct areas of
breakthrough products and
services that help determine
what is needed in relation to
the application. Supported
by a global network in more
than 150 countries, backed by
local service and support from
more than 2,000 certified
professionals, Emerson
Network Power is uniquely
positioned to provide systems
and integrated solutions
wherever our customers are
located.
Emerson Network Power
understands the challenges
of setting up the right
infrastructure to support
business-critical data center
operations and helps respond
to any demand by providing
innovative solutions, allowing
customers to concentrate on
their business requirements.
The Liebert HPM direct
expansion cooling unit
is equipped with the
most advanced industry
technology, guaranteeing
precise cooling of data
centers and server rooms.
It comes complete with
R410A refrigerant which
allows the unit to reach
significant levels of
efficiency. Liebert HPM
incorporates Emerson
Network Power's breadth
of cooling expertise in a
unique range of cabinet air
coolers designed to ensure
performance and reliability.
The Liebert HPM range
comes complete with EC Fans
as standard, thus ensuring
top energy efficiency. The
complete unit design has
furthermore been optimized
with enhanced heat
exchangers, delivering a high
level of overall efficiency and
cooling capacity.
In addition, the Liebert HPM
also includes unique Digital
Scroll technology, making
it the ideal, scalable cooling
system able to expand with
evolving business needs.
The Digital Scroll modulating
capability greatly contributes
to the efficiency levels reached
by the Liebert HPM with a
50 kW unit (inclusive of Digital
Scroll) consuming as little as
a 10 kW unit, thus delivering
advantageous energy savings.
Liebert HPM designed
for the lowest air resistance
Liebert HPM Technology Delivers Energy
Savings of up to 65%
Liebert HPM Digital Scroll
+ EC Fan
Increased motor efficiency
+ EXV
Minimized condensing
temperature & enhanced
evaporation
+ Humidifier
SHR*=1 eliminating need
for humidifier
+ COP* & SHR*
Liebert HPM has higher COP*
& SHR* at modulated capacity
Precision
Cooling Unit
with standard
scroll compressor
Saving
Liebert HPM
Digital Scroll
Compressor
up to
50%
SmartAisleTM
The Liebert HPM's patented
software allows modulation of
fan speed and cooling capacity,
meeting the necessary airflow at
the required server temperature,
while conserving Watt usage.
Saving
up to
SmartAisleTM
65%
1,000
2,000
3,000
4,000
5,000
6,000
7,000
YEARLY ENERGY COST
Data Center Set Point: 24C - 50 rH%
Energy Cost: 0.12/kWh
A 20 kW Unit equipped with Digital Scroll working at 80% heat load
Annual savings achieved by the Liebert HPM, complete with the most advanced technologies in the market (Digital Scroll Compressor,
Electronic Expansion Valve, EC Fan) as standalone and integrated with cold aisle containment, compared to Precision Cooling units fitted
with standard scroll.
Key Benefits Achieved with
Liebert HPM Scroll
Securing IT Investments
Digital Scroll technology delivers
increased performance with
a greater return on investment
while at the same time reducing
the demand on energy usage.
*COP: coefficient of performance SHR: sensible heat ratio
Targeted Cooling
Digital Scroll provides the
necessary level of cooling by
adjusting its delivery according
to the heat load, thus ensuring
constant, precise temperature
levels.
Scalable Architecture
the Liebert HPM's scalable
architecture adapts to increases
in data center density and size,
regulating its performance to
respond to evolving demands.
Unique Technology
the Digital Scroll technology
guarantees protection for IT
infrastructure with maximized
energy savings.
Integrated with SmartAisle,
the Liebert HPM is the ideal
response to data center
cooling demands and
maximizing capital investment.
Designed for R410A Refrigerant
digital scroll
digital scroll
23
22
23
21
22
20
21
19
20
18
19
17
18
17
Copeland Digital Scroll
Technology: the best solution
in terms of variable cooling
capacity
Digital Scroll based technology
allows for close monitoring and
control of room temperature
EC Fans for optimized airflow
distribution
digital scroll
23
22
21
20
19
18
17
digital scroll
23
22
21
20
19
18
17
digital scroll
23
22
21
20
19
18
17
Precision cooling floor mount
products comply with the European ErP
2015 Directive requirements, respecting
environmental commitments, while
reducing operating costs
First class energy efficiency
achieved through the combination
of market leading technologies
Continuous monitoring of heat
load ensures that only necessary
kilowatts are invested in targeted
cooling, thus conserving energy
Emerson Network Power
supports customers with
an extensive service offering,
guaranteeing availability and
total peace of mind 24/7
Constant Cooling Control Liebert iCOM control drives
the Liebert HPM to the highest
efficiency levels. The iCOMdevice,
featuring a unique control
algorithm ensuring top reliability
in all conditions, manages the
operation of the Liebert HPM units.
Liebert HPM units with graphic display may be centrally monitored and controlled
with the optional wall mounted display. The display allows access to the unit via the
Network, making coordination between the Liebert HPM units within the same
room possible as a result of the integrated Ethernet connection.The self monitoring
of redundant units alternates standby positions and gives priority to possible hot
spots. The high-level supervision of multiple units allows them to work together as
a single system to optimize room temperature and humidity. This is of particular
importance when the EC Fan is considered. EC fan power consumption functions
according to the square-cube law, so that having five units running at 80% instead of
four at 100%, means the energy used by the additional unit is cut by 50% and the total
energy used by the entire group by 36%. iCOM manages the reduction of fan speed
whenever operation at full capacity is not required.
Smart mode is a control
algorithm developed for
SmartAisleTM applications,
(Cold Aisle containment)
meeting the exact cooling and
airflow needs of the servers
without wasting a single Watt
on unnecessary cooling or air
movement.
Unit to Unit Communication
iCOM directly connects with the facility network (Ethernet) and enables communication between multiple
Liebert HPM units for synchronized operation, guaranteeing higher reliability and precision cooling room
control.
7
Liebert HPM's
integration in
the SmartAisle
configuration
achieves energy
savings of up
to 65%
TM
1
SmartAisle
Cold Aisle Containment
The physical separation of cold and warm
air zones using SmartAisle technology.
Aisle Containment ensures that the cold
air distributed through the raised floor is
delivered directly to IT cabinets.
The SmartAisle containment solution
also incorporates enhancements in
cooling efficiency which can be achieved
using the following equipment:
Cable entry sealing systems
Cabinet sealing with trims and blanking
panels
High airflow perforated floor tiles with
up to 85% perforation.
2
iCOM
with SmartAisleTM Control Logic
A cooling unit with SmartAisle control
logic ensures the correct airflow, air
*SHR: sensible heat ratio
Standard unit
Traditional
Approach
Digital Unit
Traditional
Approach
With Cold Aisle
Containment
With
SmartAisle
Compressor
61.1%
35.4%
30.3%
27.2%
Condenser
4.9%
4.9%
4.9%
4.9%
Evaporator Fan
18.6%
9.7%
6.8%
2.1%
Humidifier
15.4%
1.2%
1.2%
1.2%
Total
100%
51.2%
43.2%
35.4%
Saving
49%
Saving
57%
Saving
65%
Total Saving
Integration with SmartAisleTM, Emerson Network Power's cold aisle containment
solution, can achieve an energy saving of up to 65% higher than other manufacturers'
cooling units with standard technology. The intelligent control of the Digital Scroll
compressor capacity together with accurate fan speed management, driven by cold
aisle conditions, guarantees increased savings.
temperature and humidity required by
IT equipment. Dynamic fan speed and
cooling capacity control further provide
maximum cooling efficiency.
3
Liebert HPM
Liebert HPM's Digital Scroll compressor
delivers the exact level of required air
temperature while the EC Fans manages
the desired airflow. This ensures that only
the necessary kilowatts of input power
are used to cool the IT load. Units which
include the Alco Electronic Expansion
Valve, are able to further increase overall
system efficiency by reducing the
condensing temperature during cooler
seasons and at the same time preserving
the SHR*.
4
Liebert HPA
Liebert HPA is a remote air cooled
condenser for room-based precision
cooling units which is equipped
with variable fan speed control,
specifically developed for Digital Scroll
units. This solution maximizes system
efficiency and minimizes, annual energy
consumption.
5
Racks & Integrated Cabinets
Emerson Network Power's Knrr server
racks allow for flexible installation
of accessories, as well as a complete
cable management system. The server
rails guarantee simplified installation
of all types of 19 servers and related
accessories.
2
1
Liebert HPM:
Remote
Monitoring
Service and
Connectivity
LIFE.net Remote Monitoring
and Diagnostic Service
It is essential that your critical
cooling system is maintained in
an optimum state of readiness at
all times. With LIFE.net remote
monitoring and diagnostics,
Emerson Network Power Services
monitor and prevent possible
alarm conditions. This allows
effective proactive maintenance
and fast incident response, giving
customers complete security and
peace of mind.
Basic Web Access
10
The customer will be informed
about the status of the
installation through detailed
reporting providing valuable
information on unit functioning
and trends over any selected
period of time.
SiteScan Web Control,
Data Capture, Energy
Management and Planning
LIF
Advanced Access
With Intellislot Card
Service center engineers are
permanently on hand to provide
immediate fault analysis and
appropriate corrective action.
E . n et
Monitoring and
Alarm Notification
Through Liebert
Nform
Basic Web Access
Basic operational information can
be made available through the
monitoring feature offered by
the iCOM Control over Ethernet.
A web browser is the only
requirement needed for the unit
to communicate directly with the
local or remote web interface.
Monitoring and Control
Through Existing Network Via
your Web Browser
The Liebert HPM system
can be fitted with a Liebert
IntelliSlot Web Card allowing full
advantage to be taken of the
Ethernet network and remote
monitoring from your computer
desktop, network operations
center or any network access
simply utilizing a standard web
browser. A standard web browser,
via HTTP protocol or Network
Management System software
via SNMP protocol, can be used to
access the unit information.
Monitoring Integration
with Existing Building
Management System
If required, Liebert HPM may
be integrated with an existing
Building Management System,
while the IntelliSlot 485 Cards
provide Modbus RTU and Modbus
TCP compatibility. SCADA
support is completed through
the Bacnet over IP card.
Liebert Nform Software
Centralized Management
As business grows, critical
equipment infrastructure
expands, thus the need for
centralized management
of any equipment is key to
business success. Connecting
to equipment in the distributed
critical space is only part
of the monitoring challenge.
Liebert Nform leverages
the network connectivity
capabilities of Liebert HPM to
provide centralized monitoring
of the distributed equipment.
Utilizing the SNMP and Web
technologies integrated
in each Liebert IntelliSlot
communication card, Liebert
Nform centrally manages
alarm notifications and provides
an intuitive interface to access
critical status information.
Liebert Nform allows critical
system information to be readily
available to support personnel
wherever they are, increasing
responsiveness to alarm-event
conditions, thus allowing IT
organizations to maximize their
system availability.
Liebert SiteScan Web Control,
Data Capture, Energy
Management and Planning
For customers who require
extensive management of critical
system equipment spanning
multiple locations in an evermoving global enterprise, Liebert
SiteScan Web will centrally
manage critical equipment and
give the power to move beyond
the event responsive service
paradigm.
Liebert SiteScan Web does it all
Real-Time Monitoring and
Control
Event Management and
Reporting
Data Analysis and Trending
Building Management
Integration
Liebert SiteScan Web is a
comprehensive critical system
management solution dedicated
to ensuring reliability through
graphics, event management and
data export. The standard Web
interface allows users easy access
from anywhere, anytime.
11
Liebert HPM Application Scenarios
Liebert HPM Downflow
Downflow units are ideal for raised floor installation environments which are
commonly found in data center applications.
The Downflow unit optimizes performance in all such applications,
delivering the highest efficiency of the Liebert HPM range, which can be
further maximized with Digital Scroll.
Suitable for:
Raised Floor
SmartAisle
Liebert HPM Upflow
Upflow units are designed for use in applications with top directed air
distribution, including or excluding ducting systems. The inclusion of EC Fans
means that the Liebert HPM Upflow is able to deliver the highest External
Static Pressure (ESP), while limiting power input and maximizing output.
This combination allows the Liebert HPM to deliver optimized cooling
requirements, while at the same time providing the most suitable airflow
and ESP to meet individual installation requirements.
Suitable for:
Ducted Applications
Application with limited raised floor air distribution capabilities or where
raised floor is not available
Technical rooms
Liebert HPM Displacement
Displacement units take their name from the displacement effect. It consists
of the stratification of cold air in the lower section of the room, and hot
air in the upper section. This is achieved by delivering cooled air at a very
low speed. The displacement effect considerably contributes to system
efficiency. The Liebert HPM Displacement unit is best suited to small
applications where scalability and capacity growth are key.
Suitable for:
Application without raised floor
Technical rooms
Small data rooms with cooling installed opposite racks
12
Liebert HPM Cooling Configurations
Liebert HPM Air Cooled
Air cooled direct expansion units optimize condensing temperature in the simplest
installation configurations and with minimized site impact.
Liebert HPM Water Cooled
The Liebert HPM Water Cooled is the ideal configuration for leveraging the digital benefits
of applications with significant distances between internal and external units, or those with
variations in geodetic height.
Liebert HPM Dual Fluid Air Cooled
Ideal for chilled water based applications which transition between Air Conditioning and Precision
Cooling, the Liebert HPM Dual Fluid Air Cooled configuration, offers efficient direct expansion
cooling that works as redundant cooling for chilled water coils.
Liebert HPM Dual Fluid Water Cooled
This cooling configuration perfectly adapts to any installation layout, therefore chillers and dry
coolers can be placed wherever necessary on the site.
Liebert HPM Freecooling
For all applications where efficiency is a prime objective, the Liebert HPM offers the possibility
of leveraging the Freecooling effect for the longest period of time, as a result of its enhanced coil
distribution. The flexibility of the Liebert HPM Freecooling configuration ensures the highest
energy savings and efficiency in variable working conditions including DX mode.
13
Liebert HPM Range and Performance
Single Circuit
Room Unit Model
Condenser Model
D1E
D1G
D2E
D3A
D3G
D4E
HCR24
HCR24
HCR43
HCR43
HCR43
HCR59
Total gross cooling capacity
kW
15.8
17.4
23.9
29,0
34.9
44.1
Net sensible cooling capacity
kW
13.9
15.9
20.5
25.2
33.0
40.4
SHR* at full load
0.92
0.95
0.92
0.92
0.98
0.96
SHR* at 80% load
1.00
1.00
1.00
1.00
1.00
1.00
Net sensible EER at full load
3.2
3.1
3.0
3.1
3.4
3.2
Net sensible EER at 80% load
3.4
3.2
3.1
3.1
3.4
3.2
m3/h
4.200
4.930
5.750
7.080
9.540
11.230
Pa
400
380
190
200
400
320
Sound pressure level
at 2 meters in f.f. conditions
dB(A)
48.8
49.2
50.0
55.4
55.8
57.4
Minimum net sensible
capacity during modulation
kW
3.2
4.1
5.1
6.2
8.6
9.9
Internal Unit Dimensions
(W x D)
mm
750 x 750
750 x 750
750 x 750
1000 x 850
1750 x 850
1750 x 850
External Unit Dimensions
(W x D)
mm
1112 x 1340
1112 x 1340
1112 x 1340
1112 x 2340
1112 x 2340
1112 x 2340
Weight Internal Unit
kg
240
250
270
415
570
600
Weight External Unit
kg
75
75
92
92
92
102
D, U, F*
D, U, F*
D, U, F*
D, U, F*
D, U*
D, U*
Airflow
Max. ESP
Airflow Delivery (downflow,
upflow, displacement/frontal)
Performance at 24C 50%
Nominal ESP 20 Pa
External Temperature 35C
System able to work at up to 40C external temperature with condenser models as shown; higher ambient operating temperatures available with alternative condenser selections.
Internal Unit Height 1950 mm; External Unit Height 907 mm
*SHR: sensible heat ratio D: downflow U: upflow F: frontal
14
Liebert HPM Range and Performance
Double Circuits
Room Unit Model
Condenser Model
D3F
D4H
D5D
D7L
D8F
2 x HCR24
2 x HCR33
2 x HCR43
2 x HCR43
2 x HCR51
Total gross cooling capacity
kW
36.3
45.1
58.4
65.2
81.3
Net sensible cooling capacity
kW
34.0
41.5
49.4
53.4
71.0
SHR* at full load
0.97
0.96
0.90
0.87
0.93
SHR* at 80% load
1.00
1.00
1.00
0.95
1.00
Net sensible EER at full load
3.4
3.2
3.0
2.8
2.7
Net sensible EER at 80% load
3.6
3.4
3.2
3.1
2.8
m3/h
9.490
11.370
12.910
13.470
20.020
Pa
400
310
200
150
120
dB(A)
56.0
58.3
58.7
58.5
67.4
Minimum net sensible
capacity during modulation
kW
3.5
4.2
4.8
5.3
6.8
Internal Unit Dimensions
(W x D)
mm
1750 x 850
1750 x 850
1750 x 850
1750 x 850
2550 x 890
External Unit Dimensions
(W x D)
mm
2 x (1112 x 1340)
2 x (1112 x 1340)
2 x (1112 x 2340)
2 x (1112 x 2340)
2 x (1112 x 2340)
Weight Internal Unit
kg
580
585
620
645
950
Weight External Unit
kg
2 x 75
2 x 80
2 x 92
2 x 92
2 x 93
D, U*
D, U*
D, U*
D, U*
D*
Airflow
Max. ESP
Sound pressure level
at 2 meters in f.f. conditions
Airflow Delivery (downflow,
upflow, displacement/frontal)
Performance at 24C 50%
Nominal ESP 20 Pa
External Temperature 35C
System able to work at up to 40C external temperature with condenser models as shown; higher ambient operating temperatures available with alternative condenser selections.
Internal Unit Height 1950 mm; External Unit Height 907 mm
*SHR: sensible heat ratio D: downflow U: upflow F: frontal
15
Liebert HPM Range and Performance
Single Circuit
Model
Sel. Condenser
S1E
S1G
S2E
S2G
M2H
M3A
M3G
M4E
M5B
HCR24
HCR24
HCR43
HCR43
HCR43
HCR43
HCR43
HCR59
HCR76
Total gross cooling capacity
kW
15.6
17.4
23.1
25.0
24,6
28.8
35.1
43.8
50.7
Net sensible cooling capacity
kW
13.8
15.6
19.9
21.5
22.5
25.5
33.8
40.0
45.2
SHR*
0.93
0.95
0.90
0.92
0.96
0.94
1.00
0.96
0.94
Net sensible EER
3.3
3.1
3.1
3.0
3.3
3.1
3.5
3.3
3.0
m3/h
4.200
4.930
5.200
5.750
6.340
7.080
9.540
11.230
12.250
Pa
400
380
280
190
300
200
400
320
260
dB(A)
48.8
49.4
52.7
50.0
54.1
55.4
55.8
56.5
57.1
Internal Unit Dimensions
(W x D)
mm
750 x 750
750 x 750
750 x 750
750 x750
1000 x 850
1000 x 850
1750 x 850
1750 x 850
1750 x 850
External Unit Dimensions
(W x D)
mm
Airflow
Max. ESP
Sound pressure level
1112 x 1340 1112 x 1340 1112 x 1340 1112 x 1340 1112 x 2340 1112 x 2340 1112 x 2340 1112 x 2340 1112 x 3340
Weight Internal Unit
kg
240
250
260
270
425
430
580
600
620
Weight External Unit
kg
75
75
92
92
92
92
92
102
136
D, U, F*
D, U, F*
D, U, F*
D, U, F*
D, U, F*
D, U, F*
D, U*
D, U*
D, U*
Airflow Delivery
(downflow, upflow,
displacement/frontal)
Performance at 24C 50%
Nominal ESP 20 Pa
External Temperature 35C
System able to work at up to 40C external temperature.
Internal Unit Height 1950 mm; External Unit Height 907 mm
*SHR: sensible heat ratio D: downflow U: upflow F: frontal
16
More than 35,000 organizations
in 70 countries depend on our
Business - Critical Continuity Promise:
your IT infrastructure stays
up to support your Business!
Liebert HPM Range and Performance
Double Circuits
Model
Sel. Condenser
M3F
M4H
M5C
M5D
M7L
L8F
L9H
2 x HCR24
2 x HCR33
2 x HCR43
2 x HCR43
2 x HCR43
2 x HCR51
2 x HCR76
Total gross cooling capacity
kW
34.5
45.3
49.8
57.9
66.7
80.1
96.8
Net sensible cooling capacity
kW
33.2
41.6
44.6
49.2
53.0
69.6
78.7
SHR*
1.00
0.96
0.95
0.90
0.85
0.94
0.88
Net sensible EER
3.5
3.1
3.1
3.0
2.7
2.7
2.6
m3/h
9.490
11.370
12.240
12.910
13.470
20.020
21.100
Pa
400
310
250
200
150
120
70
dB(A)
56.0
56.2
57.3
58.7
60.0
67.4
66.7
Internal Unit Dimensions
(W x D)
mm
1750 x 850
1750 x 850
1750 x 850
1750 x 850
1750 x 850
2550 x 890
2550 x 890
External Unit Dimensions
(W x D)
mm
Airflow
Max. ESP
Sound pressure level
2 x (1112 x 1340) 2 x (1112 x 1340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 3340)
Weight Internal Unit
kg
590
600
635
650
670
950
1000
Weight External Unit
kg
2 x 75
2 x 80
2 x 92
2 x 92
2 x 92
2 x 93
2 x 136
D, U*
D, U*
D, U*
D, U*
D, U*
D*
D*
Airflow Delivery
(downflow, upflow,
displacement/frontal)
Performance at 24C 50%
Nominal ESP 20 Pa
External Temperature 35C
System able to work at up to 40C external temperature.
Internal Unit Height 1950 mm; External Unit Height 907 mm
*SHR: sensible heat ratio D: downflow U: upflow F: frontal
17
Emerson Network Power
Data Center Infrastructure for Small and Large Applications
Liebert HPC
Wide range of high efficiency Freecooling
Chillers from 40 kW to 1600 kW
Designed specifically for data center
applications and to work with SmartAisleTM
Premium energy efficiency version
iCOM control featured
Liebert HPM - Liebert PCW
From 4 kW to 230 kW, DX-Digital Scroll-CW
Premium energy efficiency
Eurovent certified performance
Unique control capabilities with iCOM
Liebert CRV
Row-based high efficiency precision cooling
units available in DX or CW versions
Decoupled control for airflow and cooling
capacity
Modulating cooling capacity with digital scroll
iCOM control with remote rack sensors
18
SmartAisle
Aisle containment
Provides highest energy efficiency
Works with any Liebert cooling unit
Service
Emerson Network Power supports
Business-Critical Continuity with the
largest global services organization
in the industry and a service offering
dedicated to entire critical infrastructure,
delivering:
Design, installation and startup
Warranty service
Preventive maintenance
24/7 remote monitoring
Emergency service
Site audits
Service contracts
Regular service of business critical
infrastructure provides uptime assurance
and reduces the total cost of ownership
over the life of equipment.
A service contract ensures that
infrastructure is regularly maintained
in order to avoid unexpected, costly
downtime. Emerson Network Power
service contracts cover all technologies
and can be tailored to suit individual
business needs.
LIFE.net
Maximized system availability via
Liebert XD
Refrigerant based high density cooling
installed close to the server
Hot spot management for up to 30 kW
per rack
On-demand upgrade with plug and play
High efficiency and 100% sensible cooling
real-time diagnosis and resolution of
operating anomalies
24-hour real-time monitoring by expert
engineers
Monitoring and trending of system data
Diagnosis through expert data
analysis allowing effective proactive
maintenance and prevention of future
anomalies
Alarm notification
On-site corrective maintenance
dispatching
19
Ensuring The High Availability
Of Mission-Critical Data And Applications.
About Emerson Network Power
Emerson Network Power, a business of Emerson (NYSE:EMR), delivers
software, hardware and services that maximize availability, capacity and
efficiency for data centers, healthcare and industrial facilities. A trusted
industry leader in smart infrastructure technologies, Emerson Network
Power provides innovative data center infrastructure management
solutions that bridge the gap between IT and facility management and
deliver efficiency and uncompromised availability regardless of capacity
demands. Our solutions are supported globally by local Emerson
Network Power service technicians.
Learn more about Emerson Network Power products and services at
www.EmersonNetworkPower.com
Locations
Emerson Network Power
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
[email protected]
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
[email protected]
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Tel: +1 614 8880246
Asia
7/F, Dah Sing Financial Centre
108 Gloucester Road, Wanchai
Hong Kong
Tel: +852 2572220
Fax: +852 28029250
While every precaution has been taken to ensure the accuracy and completeness
of this literature, Liebert Corporation assumes no responsibility and disclaims
all liability for damages resulting fromuse of this information or for any errors or
omissions.
2012 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change
without notice.
MKA4L0UKHPM Rev.1-07/2012
Emerson Network Power
The global leader in enabling Business-Critical Continuity
AC Power
Embedded Computing
Outside Plant
Racks & Integrated Cabinets
Connectivity
Embedded Power
Infrastructure Management & Monitoring
Power Switching & Controls
Services
Precision Cooling
Surge Protection
DC Power
Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2012 Emerson Electric Co.