Calculo de Conexion
Calculo de Conexion
ITEM:
Connection :
Flange Description:
ext.tubo
Dt=
int.tubo corroido d=
Wall thickness:
tw=
Design Pressure:
P=
Design Temperature: T=
Allowable Corrosion: C=
Shell thickness:
t=
Tube Stress :
Sn=
Shell Stress:
S=
in Vessel :
D=
Joint Eff.
:
E=
Joint Eff
Wall thickness STD
=
Proy interna del tubo H=
tn=tw-C
26-E-302
S2
Located (Head(1) or Shell(2)):
6",Sch80,300lbs,SA-105
6.625 in
6.011 in
0.43 in
100 psi
400 F
0.125 in
0.6250 in
t req.shell =
17100 psi
20000 psi
49 in
1
E1=
1
0.24 in
0 in
tn=
0.2485 in
0.307 in
3.01 in
trn = P*Rn/(Sn*E-0,6*P)=
0.02 in
0.123
A=d*tr*F+2*tn*tr*F*(1-fr1) =
Sn=
17100 in
Sv= 20000 in
0.8550
0.8550
0.8550
1.0000 Si no hay proyeccion interna del tubo es cero
1
0.7533 in2
F=
1 by UG-37
Available Area:
A1=Larger of the following:
A1=d(E1*t-F*tr)-2tn(E1*t-F*tr)(1-fr1)=
2.2296 in2
0.5742 in2
2.2296 in2
A1=2(t+tn)(E1*t-F*tr)-2tn(E1*t-F*tr)(1-fr1)=
so A1 =
A2=smaller of the following:
A2=5(tn-trn)fr2*t=
0.123 in
0.6185 in
Sp=
Max.Dp=
Fillets:
esp. Refuerzo te=
leg41=
12.02
0.63 in
0.5 in
A2=5(tn-trn)tnfr2=
A3=2*(tn-c)*h
so A2 =
A3
A3=
Nozzle:
Reinforcement:
A5=(Dp-d-2tn)te*fr4=
0.5 in
Dp=
12 in
Si no hay proyeccion interna del tubo es cero
h=
A41=(leg41)2*fr3=
0.21 in2
A42=(leg42)2*fr4=
0.14 in2
A42=(leg42)2*fr4=
0 in2
Available= A1+A2+A3+A41+A42+A5=
Areq:Area of reinforcement required.
A1:Excess thk in the shell
A2:Excess thk. In the out.nozz. Proy.
A41:Filled weld outside
A42:Filled weld inside
A3:Excess thk. In the int. Nozz. Proy.
A5:Reinforcement pad
Atotal:
leg42=
0.3798 in2
0.3798 in2
0.28 in2
0
NO SE INCLUYE EL REFUERZO
3.1025 in2
Required
A=
0.7533
0.7533
2.2296
0.3798
0.21
0
0
0
3.1025
NO REFORCEMENT IS NEEDED
tr1 = trn + C
=
tr2 = tr + C
=
tr3 = 1/16" + C
=
tr4=Wstd*0,875+C =
tr5=greater of tr2 or tr3=
tr6=lesser of tr4 or tr5=
0.1426 in
0.2485 in
0.19 in
0.33 in
0.25 in
0.25 in
t adopt =
t adopt*0,875 =
SHELL)
in
20000 in
in
in2
L ADECUADO