INPUT DATA

ITEM:
Connection :
Flange Description:
ext.tubo
Dt=
int.tubo corroido d=
Wall thickness:
tw=
Design Pressure:
P=
Design Temperature: T=
Allowable Corrosion: C=
Shell thickness:
t=
Tube Stress :
Sn=
Shell Stress:
S=
in Vessel :
D=
Joint Eff.
:
E=
Joint Eff
Wall thickness STD
=
Proy interna del tubo H=
tn=tw-C

26-E-302
S2
Located (Head(1) or Shell(2)):
6",Sch80,300lbs,SA-105
6.625 in
6.011 in
0.43 in
100 psi
400 F
0.125 in
0.6250 in
t req.shell =
17100 psi
20000 psi
49 in
1
E1=
1
0.24 in
0 in

tn=

0.2485 in

0.307 in

Nozzle required thickness:


Rn=Dt/2-tw+C : Rn=

3.01 in

trn = P*Rn/(Sn*E-0,6*P)=

0.02 in

Required thickness tr from UG-37(a)(3): (Head)


K1=
1 by appendix 1-4
tr=P*D*K1/(2*S*E-0,2*P)=
0.1226 in

Required thk from UG-27(C) (1)(SHELL)


tr=P*R/(S*E-(0,6*P))=

0.123

Required thickness tr from UG-37(a): (Shell)


tr=P*R/(S*E-0,6*P)=
0.123 in
tr=
Required Area:
Allowable Stesses:
fr1=lesser of 1 or Sn/Sv so fr1=
fr2=lesser of 1 or Sn/Sv so fr2=
fr3=lesser of fr2 or Sp/Sv so fr3=
fr4=lesser of 1 or Sp/Sv so fr4=
fr4=lesser of 1 or Sp/Sv so fr4=

A=d*tr*F+2*tn*tr*F*(1-fr1) =

Sn=
17100 in
Sv= 20000 in
0.8550
0.8550
0.8550
1.0000 Si no hay proyeccion interna del tubo es cero
1
0.7533 in2
F=
1 by UG-37

Available Area:
A1=Larger of the following:
A1=d(E1*t-F*tr)-2tn(E1*t-F*tr)(1-fr1)=

2.2296 in2
0.5742 in2
2.2296 in2

A1=2(t+tn)(E1*t-F*tr)-2tn(E1*t-F*tr)(1-fr1)=

so A1 =
A2=smaller of the following:
A2=5(tn-trn)fr2*t=

0.123 in

0.6185 in

Sp=

Max.Dp=
Fillets:
esp. Refuerzo te=
leg41=

12.02
0.63 in
0.5 in

A2=5(tn-trn)tnfr2=
A3=2*(tn-c)*h

so A2 =
A3
A3=

Nozzle:

Reinforcement:
A5=(Dp-d-2tn)te*fr4=

0.5 in
Dp=
12 in
Si no hay proyeccion interna del tubo es cero
h=

A41=(leg41)2*fr3=

0.21 in2

A42=(leg42)2*fr4=

0.14 in2

A42=(leg42)2*fr4=

0 in2

Available= A1+A2+A3+A41+A42+A5=
Areq:Area of reinforcement required.
A1:Excess thk in the shell
A2:Excess thk. In the out.nozz. Proy.
A41:Filled weld outside
A42:Filled weld inside
A3:Excess thk. In the int. Nozz. Proy.
A5:Reinforcement pad
Atotal:

leg42=

0.3798 in2
0.3798 in2
0.28 in2
0

NO SE INCLUYE EL REFUERZO
3.1025 in2

Required

A=

0.7533

0.7533
2.2296
0.3798
0.21
0
0
0
3.1025
NO REFORCEMENT IS NEEDED

UG-45 Nozzle neck thickness check


UG-45(a)
UG-45(b)(1)
UG-45(b)(2)
UG-45(b)(4)
UG-45(b)(3)
UG-45(b)

tr1 = trn + C
=
tr2 = tr + C
=
tr3 = 1/16" + C
=
tr4=Wstd*0,875+C =
tr5=greater of tr2 or tr3=
tr6=lesser of tr4 or tr5=

0.1426 in
0.2485 in
0.19 in
0.33 in
0.25 in
0.25 in

t adopt =
t adopt*0,875 =

0.43 EL ESCHEDULE ES EL ADECUADO


0.38

SHELL)
in

20000 in

in

smaller of 2,5tn or 2,5t


2,5tn=
0.77
2,5t=
1.25
h=
0.77

in2

L ADECUADO