Mechanical Seal Replacement Prepared by: Isep Ahmady Nugraha
Standard Operating Procedures
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Complete Permit to Work and JSA Lock Out and Rack Out Power at MCC Isolate valve suction and discharge pump Open bolt valut casing Disconnect coupling and loses bolt at base plate pump Pull out pump from valute casing and open mechanical seal Mantling mechanical seal Replace oil seal Mantling new oil seal Connect valut casing Connect coupling and tighten bolt at base plate pump Open valve suction and discharge HP KO Drum pump Rack in power from MCC Test run HP KO Drum pump Housekeeping and job completed
Pump Drawing
Disassembly Housing Pump
Part Position
Oil Seal
Mech Seal
Loosen the Impeller Bolt
Replace mechanical seal
Replace Oil Seal
Assembly the impeller
impeller
Assembly the housing pump
Matur Nuwun