OBO lightning protection systems The complete range of lightning protection systems conforming to DIN/VDE
With OBO, the construction of lightning protection systems in accordance with guidelines VDE 0185 becomes a matter of routine. With safety. These selected OBO components make it easier and more economical than ever before to construct lightning protection systems conforming to DIN/VDE. On the basis of years of experience, a lightning protection kit consisting of proven components which are
easy to install has been assembled for single and multi-family houses. The high quality means you can be sure of two things: satisfied customers and protection from lightning. Another significant advantage is the slimming-down of the product range a result of applying the modular principle, which makes the range easy to stock and understand. You will quickly see for yourself as soon as you have studied this brochure in more detail how few parts are
needed to install lightning protection in line with DIN/VDE 0185, and how much simpler and more attractive this future-proof and profitable area of business consequently becomes for electrical installation firms.
Many lightning protection components are also available in copper or brass. Ask your electrical wholesaler.
The lightning collector is the part of the external lightning protection system that is designed to collect the lightning.
The conductor system is the part of the external lightning protection system that is designed to conduct the lightning current from the collector to the earthing installation.
The earthing installation is the part of the external lightning protection system that carries the lightning current into the earth.
The lightning protection potential equalisation is the part of the internal lightning protection system that reduces potential differences caused by the lightning current.
Lightning is one of the natural phenomena that has always fascinated mankind. Although much marvelled at, lightning presents considerable danger to people and their surroundings. Differences in electrical charge between the inside of clouds and the earth, which occur predominantly in the summer months, lead to storm fronts. The lightning that we see consists mostly of an impressed negative current flowing from the clouds to the earth. If a building is struck by lightning, the lightning current heats up the point where the lightning struck and the masonry itself. This could cause fire to break out.
In Germany, several hundred million euros worth of damage is caused by lightning strikes every year. Lightning protection systems professionally installed in accordance with the regulations offer effective protection from direct lightning strikes. DIN/VDE standard 0185 Part 1 and Part 2 of November 1982 is still the basic guide to the installation and testing of lightning protection systems. Recommended standards are ENV 61024-1, and for Germany DIN/VDE 0185 Part 100 and DIN/VDE 0185 Part 103, since these publications reflect the current state of technology knowledge. Depending on the construction and use of the building, and the consequential damage weighed against the accepted frequency of lightning strikes, one of four lightning protection classes is assigned for the building to be protected.
The lightning protection classes (BKZ) define parameters that are necessary for the installation of a lightning protection system. The table above lists the lightning protection classes and their associated peak lightning current values.
A program to calculate lightning protection classes in accordance with IEC 61024-1, DIN V VDE 0185 Part 100 is available on request.
Structure of a lightning protection system A lightning protection system (LPS) is made up of the following function units: 1. Lightning collector: the part of the external lightning protection system that is designed to collect the lightning.
A. Protective angle method The protective angle method is a way of designing a lightning collector. The building to be protected must be situated within the space protected by the collector rods or the collector device. The protective angle depends on the height of the building; it can be taken from DIN V VDE standard 0185 Part 100. Taking a protective angle of 45 as an example, buildings up to 30 metres high can be protected (BKZ 3 < 23 metres, BKZ 2 < 15 metres, BKZ 1 < 10 metres).
B. Mesh method Another way of setting up a lightning collector is the mesh method. Starting from the preferred lightning strike points, such as ridges, hips and edges, collector wires are laid on the roof surfaces in the form of a mesh. The table below shows the mesh dimensions for each lightning protection class.
C. Lightning sphere method Collector designs can also be determined with the lightning sphere method. This method requires a model of the object to be protected and a sphere that is rolled over the model. A lightning collector must be installed at all points touched by the sphere. With this method too, the lightning protection class determines the degree of protection to be expected, on the basis of the radius of the sphere. The lightning sphere method is intended for larger and more complex buildings, where the higher cost compared with the protective angle method and the mesh method is justified.
B. Mesh method
45 area protected
H Max. 20 m
2. Lightning conductor system: the part of the external lightning protection system that is designed to conduct the lightning current from the collector to the earthing installation. The number of lightning conductors depends on the size of the building to be protected, but at least two conductors must be installed. When installing lightning conductors, it is essential to keep current paths short and to avoid loops. The table below shows the distances between the conductors and the associated lightning protection classes.
Mesh size 10 m 15 m 20 m 25 m
4. Lightning protection potential equalisation: the part of the internal lightning protection system that reduces potential differences caused by the lightning current. For this, power wiring and data wiring (telecommunication wires, control system wiring, cable television, etc.) must be included in the lightning protection potential equalisation. This is done with lightning arresters of requirement class B to DIN VDE 0675 Part 6 (A1/A2). Electric power lines must be connected to the lightning arresters of requirement class B as close as possible to the place where they enter the building (the domestic connection box, for example). Here are two installations by way of example:
If the meter is not located immediately adjacent to the domestic connection box, the lightning arrester must be installed upstream of the meter. Here, the installation must be approved by the local electricity supply company. In this case we recommend lightning arrester type MC 50B (see page 18). This arrester satisfies all the conditions of the VDEW guidelines and bears VDE, VE and KEMA KEUR approval marks. It is advisable to install surge protection of requirement class C to DIN/VDE 0675 Part 6 (A1/A2) as well as the lightning arresters. Even if the surge arrester is not strictly required by the regulations, it is important to suggest to the customer that surge protection should be provided as well.
L1 L2 L3 N
F1 Wh
Installation examples 1 1a 2 Lightning arresters NPE spark gap Equipotential bonding conductor Main equipotential bonding bar Earth connection Main fuses
DCB 1 1a
4 PE
3 4 F1
Wh
3. Earthing installation: the part of the external lightning protection system that carries the lightning current into the earth. Examples of common earthing systems such as single earthing devices (deep earths, radial earths, plate earths), ring earth (surface earths) or foundation earths are shown on the pages that follow.
3 RB TT system F1 RA
L1 L2 L3 PEN
Combinations of materials Material Steel, hot-dip galvanised Aluminium (Alu) Copper (Cu) Stainless steel (VA) Steel, hot-dip galvanised (FT) recommended possible not recommended possible Aluminium (Alu) possible recommended not recommended possible Copper (Cu) not recommended not recommended recommended possible Stainless steel (VA) possible possible possible recommended
Materials and hardware Wherever there is a junction between different materials there is a risk of corrosion. For this reason, copper parts should never be installed together with galvanised surfaces or aluminium components, since rain or other effects may result in copper particles reaching the galvanised or aluminium surfaces. Places where there is a high risk of corrosion, for example where conductors enter concrete or the ground, must also be protected from corrosion. Buried connections must be suitably coated to prevent corrosion. Bare aluminium must not be placed in direct contact with plaster, mortar or concrete and must not be buried. The table above shows some combinations of metals that are possible from the point of view of contact corrosion.
Testing lightning protection systems After acceptance testing, lightning protection systems must be re-tested at set intervals to ensure that they are still working properly and to allow improvements to be made where possible. The tests should be carried out with reference to DIN VDE standard 0185 Part 110 and its technical principles. A test report covering the following points must be written:
Tested lightning protection components Components for the construction of lightning protection systems used to be defined by the series of standards DIN 48801 to DIN 48852, which gave prominence to component dimensions. In August 1999, EN 50164-1 (DIN/VDE 0185 Part 201) came into force. Connection components are tested to this standard. After a conditioning phase totalling ten days, the components are subjected to three current surges. They are assigned to one of two test classes: Test class H
General condition of collector cables and other collector system components. General condition of the degree of corrosion. Soundness of the fixings of the cables and the components of the lightning protection system. Any deviations from the requirements of IEC 61024-1.
EN
H
5 0 1 6 4-
Test class N Documentation of all changes and additions to the LPS and changes to the physical installation. In addition, final drawings and the draft description of the LPS must be checked. Test results.
EN
N
5 0 1 6 4-
Tested with three 50 kA current surges, waveform 10/350 s. Further information on our lightning protection components tested to EN 50164-1 is available on request.
! @ BM
@
Round conductor Type Rd8/ALU-T
BO
BP
$
#
Roof cable holder Type 132/K-VA
BQ
$ ^
$
Roof cable holder Type 157/FK-VA
BR
^ ^ ( * BM BN BM BP BS & BR BL BQ BO BP BS ( CU
( * ^
CU
&
BL
BM
A ring earth is a surface earth which is laid, if possible, in a closed ring around the outside foundation of the building at a distance of one metre and a depth of half a metre. Earth entry bars of galvanised steel must be treated to prevent corrosion over at least 30 cm upward and downward from the surface of the ground. Anti-corrosion bandage type 356 is suitable for this purpose. Non-permanent connections in the ground must also be protected with an anti-corrosion bandage. The cable holders and roof cable holders should not be more than 1.2 m apart. The ring earth must have a conducting connection to the equipotential bonding bar.
BN
! @ BM # %
!
Lightning rod Type 101/G-DIN
BO
BS
BP
BQ
$ ^
$
Roof cable holder Type 157/FK-VA
BR
^ ^ * BM BN BM BP ( & BQ BR BL CU BT CL CU BQ BO CU BU
( * ^
BS
BT
&
BU
CL
CU
BL
BM
A deep earth rod is an earth rod which is driven down to a great depth, usually vertically. For each lightning conductor, a single deep earth rod nine metres long (according to DIN VDE 0185 Part 1) must be installed about one metre away from the foundation of the building. According to DIN VDE 0185 Part 100, there are additional aspects to consider. The required earth rod length may be divided into several lengths connected in parallel. Depending on the nature of the ground, earth rods are driven in manually or with a suitable electric, petrol or pneumatic power hammer. Removable connections in the soil must be protected from corrosion (with a flexible corrosion bandage).
BN
CO CR % ! ! CO % DN CR BS CT CS
!
DM DM %
CO
CO BS
CO
CP
CR
BL
CS
DM
BM
Rod holder Type 113/Z-16
CT
DM
BN
Earth entry bar Type 200
CU
CP BL BN BO BN CP CU BO BM BN BQ BR BL BO CN
BR
Equipotential bonding bar Type 1801/VDE
BM BN
BO
DM
BO
BQ
DN
BS
CU
CM
A foundation earth is a conductor embedded in the concrete foundation of a building, which provides an earth for lightning protection, among other things, if the terminal tabs needed to connect the lightning conductors are brought out from the foundation. Branches and connections in the foundation can be made by means of wedge connectors. Wedge connectors must not be used in the ground. When installing the foundation earth rod, we recommend using strap holders to ensure a clean run. The holders (21) should be positioned about two metres apart. On flat roofs, roof cable holders should not be more than one metre apart. The sheet metal covering is used as a lightning collector. Where the conductor is more than 20 metres long, at least one expansion piece is needed.
Spacer Type 1811
CN
10
11
Lightning rods
1
157/FK-VA For tiled roofs, with cable holder 177/20 of grey polyamide, lower part of stainless steel
Type To fit mm Lengt h mm Material Pack qty Weight kg/100 Order no.
101/G-DIN 16 mm Similar to DIN 48802, Form A3 With forged-on tab, rounded; fitted with connector (one-piece) 5001 DIN for round conductor Rd 8-10
Type Length mm Nom. size mm Pack qty Weight kg/100 Order no.
50 50 50
157/LK-VA For slate roofs, with cable holder 177/20 of grey polyamide, lower part of stainless steel
FT
101/G-DIN 101/G-DIN
1000 1500
16 16
10 10
164.300 240.000
5402107 5402158
4
Type To fit mm Material Pack qty Weight kg/100 Order no.
Round conductors
157/LK-VA
Rd 8-10
VA/PA
50
8.000
5215374
2
RD 8/ALU-T Material: aluminium, soft, twist quality Rd 8/ALU-T
Type
5
249/ST Suitable for connecting round conductors Rd 8 and Rd 10 The design allows parallel, tee and cross connections to be made
Type To fit mm Material Pack qty Weight kg/100 Order no.
mm 8
Material
Weight kg/100 m
Order no.
RD 8/ALU-T**
Alu***
13.500
5021294
FT Alu VA
50 50 50
Gutter clips
6
Blitzschutz--Bauteile_GB_V0_2009200
132/K-VA With cable holder 177/20 of grey polyamide, lower part of stainless steel
Type To fit mm Material Pack qty Weight kg/100 Order no.
262 To connect cables to gutters (of steel = 262/A-DIN / of copper = 262/ZM), suitable for all edge bead thicknesses. Fitted with 2 screws DIN 933/M6 x 12 and 2 screws DIN 933/M8 x 30, stainless steel
Type To fit mm Material Pack qty Weight kg/100 Order no.
132/K-VA 132/K-Cu
Rd 8-10 Rd 8-10
VA/PA Cu/PA
50 50
10.900 11.600
5202515 5202590
262 262/ZM
Rd 8-10 Rd 8-10
FT Cu/FT
25 25
19.610 23.100
5316014 5316170
12
Cable holders
7
113/Z 8-10 Suitable for round conductor Rd 8-10, with crossbar, fitted with 2 M6 x 16 hexagon head screws, with M8 female thread and through hole
Type To fit mm Material Pack qty Weight kg/100 Order no.
9
324/S To guide, clamp and hold round conductors Rd 8 and Rd 10 to gutter downpipe brackets, steel structures, etc. Prefitted with M8 x 25 hexagon head screw, nut and serrated lock washer Material: stainless steel
Type To fit mm Material Pack qty Weight kg/100 Order no.
113/Z 8-10
Rd 8-10
Zn
50
6.202
7
Test joints
113/B-Z-HD 8-10 Suitable for round conductor Rd 8-10, with crossbar, fitted with 2 M6 x 16 hexagon head screws, of stainless steel VA (1.4303), 5 x 60 wood screw and 8 mm plastic plug
Type To fit mm Material Pack qty Weight kg/100 Order no.
10
223/DIN DIN 48835, Form A Pack: 50 Suitable for round conductor Rd8/Rd10 with round conductor Rd 16, fitted with hexagon head screws, DIN 48835, Form A, closed design Clamp body of die-cast zinc, screws of stainless steel
Type To fit mm Material Pack qty Weight kg/100 Order no.
113/B-Z-HD 8-10
Rd 8-10
Zn
100
6.580
5230322
223/DIN
8-10/16
Zn
50
12.850
5335205
8
301/S With bead, cable holder for gutter downpipes
Type For pipe mm Material Pack qty Weight kg/100 Order no.
10
226
Type To fit mm Material Pack qty Weight kg/100 Order no.
301/S 301/S
100 120
FS FS
50 50
5.200 5.950
5351057 5351073
FT Cu VA
50 50 50
8
301/V With two 7 mm connecting holes, one 9 mm connecting hole and one 11 mm connecting hole. Adjustable for 60-130 mm pipe diameter. The connecting tab is designed so that any of the following may be used as cable holders: a.) terminal block tab type 324/S b.) one-piece connector type 5001/DIN
Type Material Pack qty Weight kg/100 Order no.
Rod holders
11
113/Z-16 For lightning rods and earth entry bar 16 mm , fitted with 2 hexagon head screws DIN 84/M6 x 16, hot-dip galvanised. With M8 female thread for mounting. The through hole can be used for fixing with woodscrews. Material: crossbar and screws of galvanised steel, lower part of die-cast zinc.
Type To fit mm Material Pack qty Weight kg/100 Order no.
Blitzschutz--Bauteile_GB_V0_2009200
301/V 301/V-VA
FS V2A
5 5
11.900 11.800
5350867 5350905
113/Z-16
Rd 16
Zn
50
6.000
5412609
13
Rod holders
Strap conductors
11
113/B-Z-HD-16 For lightning rods and earth entry bars Rd 16, with crossbar, fitted with 2 M6 x 16 hexagon head screws, of stainless steel VA (1.4303), 5 x 60 woodscrew and 8 mm plastic plug
Type To fit mm Material Pack qty Weight kg/100 Order no.
15
5052 Material: steel, hot-dip galvanised/stainless steel Zinc coating: 500 g/m2 Dimensions: 30 x 3.5 mm
Type Material Standard coil m approx Weight kg/100 m Order no.
113/B-Z-HD-16
Rd 16
Zn
100
6.880
5412803
FT FT FT V2A V4A
12
200 Rounded both ends, 16 mm Material: steel, hot-dip galvanised
Type Length mm Nom. size mm Pack qty Weight kg/100 Order no.
16
FT
200 200
1500 2000
16 16
10 10
242.000 320.000
5420156 5420202
Cross-connectors
1801 VDE With 10 x 10 mm terminal rail of nickel-plated brass and terminals of electrogalvanised steel, protected from accidental contact. Cover 217 x 63 x 65.5 mm of impact-resistant polystyrene Colour: grey, RAL 7035 Possible connections: 7 conductors 2.5-25 mm2 2 conductors 25-95 mm2 1 conductor (strap conductor) 4 x 30 mm Components for on-site assembly of equipotential bonding bars can be supplied
13
252/16-FL To connect strap conductor (30 x 3.5) to earth entry bar ( 16 mm), fitted with hexagon head screws
Type To fit mm Material Pack qty Weight kg/100 Order no.
Type
Pack qty
Weight kg each
Order no.
1801 VDE
0.550
5015650
252/DIN 252/DIN
FT FT
25 25
38.000 33.530
5312345 5312310
16
14
Blitzschutz--Bauteile_GB_V0_2009200
256/... DIN 48845, Form H for strap conductor up to FL40 To fit: max. FL30 x max. FL30, max. FL40 x max. FL40 without intermediate plate, with 4 M8 x 25 hexagon head screws and 4 M8 hexagon nuts
Type Material To fit mm Pack qty Weight kg/100 Order no.
Design 1809/A for outdoor use Possible connections to equipotential bonding bar 7 solid or stranded conductors up to 25 mm2 or multi-stranded conductors 16 mm2 1 round conductor Rd 8-10 1 strap conductor FL 30 or round conductor Rd 8-10
Type Pack qty Weight kg each Order no.
256/A-DIN 256/B-A-DIN 30
FT VA
max. FL 30 max. FL 30
10 25
10.260 27.800
5314658 5314720
1809 1809/A
1 1
0.370 0.370
5015073 5015111
14
Pipe clips
Earthing rods
17
303/DIN DIN 48818, Form D Fitted with 2 DIN 933/M8 x 20 hexagon head screws and 2 DIN 934/M8 hexagon nuts, hot-dip galvanised Material: steel, hot-dip galvanised
Type For pipe inch Pack qty Weight kg/100 Order no.
19
FT
219/20 DIN 48820, Form Z System OMEX, with pin and bore Zinc coating, min. 60 mm
Type Length supplied mm Material Pack qty Weight kg each Order no.
1 11/4 11/2 2
3/ 4
5 5 5 5 5
219/20
1500
FT
3.650
5000017
18
1819/20 BP DIN 48852, Form Sp For earthing rods, system BP 2760/20 Pack: 5 For earthing rods of hot-dip galvanised steel Possible connections: flat strip up to 40 mm, round conductor Rd 10 Material: hot-dip galvanised steel
Type For deep earthing rods mm Material To fit mm Pack qty Weight kg each Order no. Type For deep earthing rods mm
20
19
Pack qty Weight kg each Order no.
TG
1819/20BP
20
10
0.035
3041212
2760/20 2760/20-VA
20 20
FT V2A
8-10/FL40 8-10/FL40
5 5
0.324 0.324
5001641 5001625 1819/20 DIN 48852, Form Sp For earthing rods, system OMEX
20
19
Weight kg each Order no. Type For deep earthing rods mm Pack qty
Earthing rods
TG
19
1819/20
20
10
0.033
3041204
Spacer
21
Blitzschutz--Bauteile_GB_V0_2009200
219/20 BP DIN 48852, Form Z System BP, with pin and bore, 219/20 BP: zinc coating, min. 60 mm
Type Length supplied mm Material Pack qty Weight kg each Order no.
FT
5 5
3.650 3.650
5000947 5000866
1811
10/FL30x3.5
250
25
0.190
5014018
15
Saddle terminals
22
1813/DIN DIN 48834, Form A
Type To fit mm Pack qty Weight kg each Order no.
25
274 Further information on our tested lightning protection components to EN 50164-1 is available on request
Type For welt thickness mm Material Pack qty Weight kg/100 Order no.
FT
1813/DIN
10/FL30 x FL30
0.200
5014212
274
max. 10
FT
50
10.400
5317428
23
288/DIN DIN 48841, Form B
Type Pack qty Weight kg/100 Order no.
26
165/MBG DIN 48829, Form B1 Filled with concrete, frost-resistant
Type
Alu
50
7.500
5320712
Connector 5001
30
To fit mm
Pack qty
Weight kg/100
Order no.
PE/PP
Rd 8 Rd 10
12 12
106.000 106.000
5218691 5218675
Connecting components
Stands
24
287/DIN DIN 48841, Form L
Type Material Pack qty Weight kg/100 Order no.
27
101/ST Concrete, frost-resistant, M16 female thread Recommended length of lightning rod 28 with 101/ST max. 1.0 m
Type Pack qty Weight kg/100 Order no.
287
Alu
50
6.000
5320704
To be used with:
Connector 5001
30
6.900
5402891
Saddle terminals
25
270 Pack: 50
Type For welt thickness mm Material Pack qty Weight kg/100 Order no.
27
28
Blitzschutz--Bauteile_GB_V0_2009200
101/B-16 Concrete, frost-resistant, M16 female thread Recommended length of lightning rod 2.5 m
Type
Pack qty
Weight kg/100
Order no.
270
max. 10
FT
50
13.810
5317207
101/B-16
16.000
5402956
16
Lightning rods
28
177/20
177/30
177/B-HD-20
177/B-HD-30
31
PA
Alu
500 500
50 50 100 100
16 16 16 16 16
10 10 10 10 5
Expansion piece
32
29
356
Type Width mm Length m Pack qty Weight kg each Order no.
Type
Pack qty
Weight kg/100
Order no.
Alu
172/AR
25
7.500
5218926
356
50
10
0.715
2360055
Jumper cable
33
Connectors
30
Blitzschutz--Bauteile_GB_V0_2009200
853/DIN: DIN 48841, Form D Steel cable 25 mm2 with black plastic covering, cable lugs of aluminium with 1 fixing hole 8.5 and 2 fixing holes 4.2
Type Pack qty Weight kg/100 Order no.
Alu
5001/DIN
Rd 8-10
Zn/FT
100
7.450
5304105
853/DIN
100
7.260
5331013
17
35
34
V 25-B: (for TN-C, TN-S systems) Lightning arrester V 25-B is intended for use in lightning protection potential equalisation to VDE 0185, Part 1, as well as Part 100. It is an arrester of requirement class B to DIN VDE 0675, Part 6 (Draft 11.89), the purpose of which is to establish lightning protection potential equalisation for the power supply line in the presence of a lightning protection system for the building. It should also be used in buildings supplied via an overhead line, since direct lightning or partial lightning currents may be expected here as well. OBO lighting arrester V 25-B has a built-in isolating device with defect indication, so that a faulty arrester module can be replaced without removing the connecting wires and switching off the power. To measure the insulation, simply withdraw the upper part of the V 25-B.
Type Pack qty Weight kg each Order no.
V 25-B/3 (TN-C) V 25-B/4 (TN-S) MC 50-B VDE: The plug-in multiple spark gap of the OBO MC 50-B VDE is a lightning arrester of requirement class B to DIN VDE 0675 Part 6 (draft 11.89), as well as Class I to IEC 61643-1 (02.98) and is designed to be used between interfaces 0A to 1 according to the lightning protection zone concept set out in IEC 1312-1. The requirements for the testability of class B surge protection devices in the VDEW guideline (first edition 1998) are comprehensively met by the use of a plug-in upper part. Since the spark gap of the device is enclosed, no plasma arcs are produced outside the casing. This means that the lightning arrester may be mounted on a standard NS 35 rail in a commercially available consumer unit.
Type Pack qty Weight kg each Order no.
1 1
0.435 0.630
5097002 5097037
35
0.400
5096847 V 25-B/3+NPE: (for TT and IT systems) Lightning arrester OBO V25-B/3+NPE for use in lightning protection potential equalisation for TT and IT systems. Four-pole modular lightning arrester to a 17.5 mm module for special use in lightning protection potential equalisation for TN-S, TT and IT systems to VDE 0185, Part 1 and Part 100, ENV 61024-1, IEC 1024-1, as well as E DIN VDE 0100 Part 534/A1. The arrester modules are self-monitoring, thanks to a thermal isolating device with function indication. Varistor blocks can be withdrawn singly from the lower part without interrupting the voltage. Guide bars prevent unauthorised removal. The arrester can be upgraded for remote monitoring by means of an infrared light barrier. The arrester conforms to requirement class B of DIN VDE 0675, Part 6 and annexes.
Type Pack qty Weight kg each Order no.
34
MC 125-B/NPE: The OBO type MC 125-B/NPE LightningController was designed to be used in TN-S, TT and IT systems as a sum current spark gap between the neutral conductor (N) and the protective earth conductor (PE). It meets the requirements of requirement class B of DIN VDE 0675 Part 6 (draft 11.89), as well as class I of IEC 61643-1 (02.98) and is designed to be used between interfaces 0A to 1 according to the lightning protection zone concept set out in IEC 1312-1. In conjunction with OBO LightningController MC 50-B VDE and in the presence of a lightning protection system for the building or overhead power lines, the MC 125-B/NPE establishes lightning protection potential equalisation. The requisite tests have been performed with reference to the lightning current parameters according to ENV 61024-1 and IEC 1024-1.
Type Pack qty Weight kg each Order no.
V 25-B/3+NPE
0.640
5097401
35
Type Pack qty Weight kg each Order no.
Blitzschutz--Bauteile_GB_V0_2009200
0.095
5097053
MC 125-B/NPE
0.520
18
Lightning rod to DIN 48802 Form A3, diameter 16 mm Length 1000 mm, rounded on one side The other side with forged-on tab and prefitted connector type 5001 DIN. Capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) for round conductor 8-10 mm diameter Supply and install Type: 101/G-DIN Order no. 5402107 Lightning rod to DIN 48802 Form A3, diameter 16 mm Length 1500 mm, rounded on one side The other side with forged-on tab and prefitted connector type 5001 DIN. Capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) for round conductor 8-10 mm diameter Supply and install Type: 101/G-DIN Order no. 5402158 Round conductor Aluminium, soft, twist quality Diameter 8 mm Supply and install Type: Rd 8/ALU-T Order no. 5021294 Roof cable holder Stainless-steel with polyamide cable holder type 177/20 for ridge tiles, width adjustable 160-260 mm Supply and install Type: 132/K-VA Order no. 5202515 Roof cable holder Stainless-steel, copper-plated, with cable holder of copper-coloured polyamide type 177/20-CU for ridge tiles, width adjustable 160-260 mm Supply and install Type: 132/K-CU Order no. 5202590 Roof cable holder Straight, stainless-steel, for tiled roofs, with polyamide cable holder type 177/20 grey. Length 230 mm Supply and install Type: 157/FK-VA Order no. 5215544 Roof cable holder Straight, stainless-steel, for tiled roofs with polyamide cable holder type 177/20 grey. Length 280 mm Supply and install Type: 157/FK-VA Order no. 5215587 Roof cable holder Straight, stainless-steel, for tiled roofs, with polyamide cable holder type 177/20 grey. Length 410 mm Supply and install Type: 157/FK-VA Order no. 5215609
Roof cable holder Straight, stainless-steel for slate roofs, with polyamide cable holder type 177/20 grey. Length 212 mm Supply and install Type: 157/FK-VA Order no. 5215374 Vario quick connector Hot-dip galvanised steel, to connect 8 and 10 mm round conductors for parallel, T and cross connections, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 249/ST Order no. 5311500 Vario quick connector Aluminium, to connect 8 and 10 mm round conductors for parallel, T and cross connections, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 249/Alu Order no. 5311519 Vario quick connector Stainless-steel, material 1.4301, to connect 8 and 10 mm round conductors for parallel, T and cross connections, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 249/VA Order no. 5311551 Gutter clip Hot-dip galvanised steel, to connect cables to gutters, suitable for edge bead thickness 15-22 mm, with stainless-steel screws Supply and install Type: 262/A DIN Order no. 5216219 Gutter clip Steel, hot-dip galvanised to DIN ISO 1461, to connect 8-10 mm round conductors to gutters, suitable for all edge bead thicknesses, with stainless-steel screws Supply and install Type: 262 Order no. 5216014 Gutter clip To connect 8-10 mm round conductors of steel or aluminium to copper gutters, suitable for all edge bead thicknesses, with intermediate plate of aluminium/copper and crossbar of steel, lower part of copper Supply and install Type: 262/ZM Order no. 52161700 Cable holder Lower part of die-cast zinc, with M8 female thread and crossbar of hot-dip galvanised steel, with 2 M6 x 16 hexagon head screws Supply and install Type: 113/Z 8-10 Order no. 5229960
4
Blitzschutz--Bauteile_GB_V0_2009200
19
Cable holder Lower part of die-cast zinc, with M8 female thread and crossbar of hot-dip galvanised steel, with 2 prefitted M6 x 16 hexagon head screws, with 5 x 60 woodscrew and 8 mm plastic plug Supply and install Type: 113/Z-HD 8-10 Order no. 5230322 Gutter downpipe bracket Hot-dip galvanised steel, to carry 8-10 mm round conductors directly behind the downpipe, including screws and nuts, for pipe diameter 100 mm Supply and install Type: 301/S Order no. 5351057 Gutter downpipe bracket Hot-dip galvanised steel, to carry 8-10 mm round conductors directly behind the downpipe, including screws and nuts, for pipe diameter 120 mm Supply and install Type: 301/S Order no. 5351073 Gutter downpipe bracket Hot-dip galvanised steel, with two 7 mm connecting holes, one 9 mm connecting hole and one 11 mm connecting hole. Adjustable for downpipes with diameters from 60 to 130 mm Supply and install Type: 301/V Order no. 5350867 Gutter downpipe bracket Aluminium, with two 7 mm connecting holes, one 9 mm connecting hole and one 11 mm connecting hole. Adjustable for downpipes with diameters from 60 to 130 mm Supply and install Type: 301/V-AL Order no. 5350921 Terminal block tab Steel, hot-dip galvanised To clamp 8-10 mm round conductors to gutter downpipe brackets or to steel structures, complete with M8 x 25 hexagon head screw, nut and serrated lock washer, stainless-steel Supply and install Type: 324/S Order no. 5326303 Terminal block tab Stainless-steel, material 1.4301, to clamp 8-10 mm round conductors to gutter downpipe brackets or to steel structures, complete with M8 x 25 hexagon head screw Supply and install Type: 324/S-VA Order no. 5326311 Test joint To DIN 48835, Form A, of die-cast zinc, with stainlesssteel screws, to connect 8-10 mm round conductors to 16 mm round earth entry bar Tested to EN 50164-1 Supply and install Type: 223/DIN Order no. 5335205
10
Test joint Hot-dip galvanised steel, to connect round conductors Rd 8-10 and strap conductors FL 30 to earth entry bar Rd 16, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 226 Order no. 5336007 Test joint Copper, to connect round conductors Rd 8-10 and strap conductors FL 30 to earth entry bar Rd 16, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 226/Cu Order no. 5336023 Test joint Stainless-steel, material 1.4301, to connect round conductors Rd 8-10 and strap conductors FL 30 to earth entry bar Rd 16, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 226/VA Order no. 5336058 Rod holder Lower part of die-cast zinc, to secure lightning rods and earth entry bars, 16 mm diameter, M8 female thread, crossbar of hot-dip galvanised steel, fitted with 2 M6 x 16 hexagon head screws Supply and install Type: 113/Z-16 Order no. 5412069 Rod holder Lower part of die-cast zinc, to secure lightning rods and earth entry bars, 16 mm diameter, M8 female thread, crossbar of hot-dip galvanised steel, fitted with 2 M6 x 16 hexagon head screws, prefitted with 5 x 60 woodscrew and 8 mm plastic plug Supply and install Type: 113/B-Z-HD-16 Order no. 5412803 Earth entry bar Hot-dip galvanised, 16 mm diameter, rounded both sides, to connect the down conductor to the earthing installation Supply and install Type: 200 Order no. 5420156 Earth entry bar Hot-dip galvanised, 16 mm diameter, rounded both sides, to connect the down conductor to the earthing installation, length 2000 mm. Supply and install Type: 200 Order no. 5420202 Cross-connector Hot-dip galvanised steel, 60 x 60 mm with intermediate plate, M8 x 25 screws (slotted) and nuts to connect 8-10 mm round conductor to 8-10 mm round conductor with intermediate plate Supply and install Type: 252/DIN Order no. 5312310
10
10
11
11
12
12
13
10
20
Blitzschutz--Bauteile_GB_V0_2009200
14
Cross-connector Hot-dip galvanised steel, 30 x 30 mm without intermediate plate, including M8 x 25 screws (slotted) and nuts to connect FL30 strap conductor in the earth. Supply and install Type: 256/A-DIN 30 Order no. 5314658 Cross-connector Hot-dip galvanised steel, 60 x 60 mm without intermediate plate, including M8 x 25 screws (slotted) and nuts to connect FL30 strap conductor in the earth Supply and install Type: 256/B-A-DIN 30 Order no. 5314720 Strap conductor For setting up earthing installations and for use in lightning protection, steel, hot-dip galvanised Dimensions W x H: 30 x 3.5 mm Zinc coating: 225 g/m2 (approx 30 m) Fixed length: 100 m, coiled Supply and install Type: 5052 Order no. 5020336 Strap conductor For setting up earthing installations and for use in lightning protection, steel, hot-dip galvanised Dimensions W x H: 30 x 3.5 mm Zinc coating: 225 g/m2 (approx 30 m) Fixed length: 25 m, coiled Supply and install Type: 5052 Order no. 5020832 Strap conductor For setting up earthing installations and for use in lightning protection, steel, hot-dip galvanised Dimensions W x H: 30 x 3.5 mm Zinc coating: 225 g/m2 (approx 30 m) Fixed length: 50 m, coiled Supply and install Type: 5052 Order no. 5020956 Strap conductor For setting up earthing installations and for use in lightning protection, stainless-steel V2A, material 1.4301 Dimensions W x H: 30 x 3.5 mm Fixed length: 50 m, coiled Supply and install Type: 5052 Order no. 5018501 Strap conductor For setting up earthing installations and for use in lightning protection, stainless-steel V4A, material 1.4571 Dimensions W x H: 30 x 3.5 mm Fixed length: 50 m, coiled Supply and install Type: 5052 Order no. 5018706
16
14
Equipotential bonding bar Tested to VDE 0618 Part 1, consisting of 10 x 10 mm nickel-plated brass terminal rail, electro-galvanised steel terminals protected from accidental contact, rail holders and cover. Also suitable for potential equalisation for lightning protection. Fitted with terminals for: 7 solid, stranded or multi-stranded conductors 2.5-25 mm2, 2 solid, stranded or multi-stranded conductors 25-95 mm2, 1 strap conductor up to FL30, max. thickness 5 mm Tested to EN 50164-1 Supply and install Type: 1801 VDE Order no. 5015650 Equipotential bonding bar Consisting of nickel-plated brass contact rail, electro-galvanised steel screws and crossbars, and polystyrene base and cover. Fitted with terminals for: 7 solid, stranded or multi-stranded conductors 2.5-25 mm2, 1 Rd 8-10 round conductor, 1 strap conductor up to FL30 Tested to EN 50164-1 Supply and install Type: 1809 Order no. 5015073 Equipotential bonding bar For outdoor use, consisting of nickel-plated contact rail, stainless steel screws and crossbars, and polystyrene base and cover, colour: black, UV-resistant. Fitted with terminals for: 7 solid, stranded or multi-stranded conductors 2.5-25 mm2, 1 Rd 8-10 round conductor, 1 strap conductor up to FL30 Tested to EN 50164-1 Supply and install Type: 1809/A Order no. 5015111 Pipe clip Hot-dip galvanised steel, to DIN 48818, Form D, width 40 mm with hole = 11 mm, prefitted with M8 x 25 screws (slotted) and M8 nuts, for pipe diameter 3/ = 26.9 mm 4 Supply and install Type: 303/DIN Order no. 5102081 Pipe clip Hot-dip galvanised steel, to DIN 48818, Form D, width 40 mm with hole = 11 mm, prefitted with M8 x 25 screws (slotted) and M8 nuts, for pipe diameter 1 = 33.7 mm Supply and install Type: 303/DIN Order no. 5102111 Pipe clip Hot-dip galvanised steel, to DIN 48818, Form D, width 40 mm with hole = 11 mm, prefitted with M8 x 25 screws (slotted) and M8 nuts, for pipe diameter 11/4 = 42.4 mm Supply and install Type: 303/DIN Order no. 5102138
16
15
15
16
15
17
15
17
15
17
Blitzschutz--Bauteile_GB_V0_2009200
21
17
Pipe clip Hot-dip galvanised steel, to DIN 48818, Form D, width 40 mm with hole = 11 mm, prefitted with M8 x 25 screws (slotted) and M8 nuts, for pipe diameter 11/2 = 48.3 mm Supply and install Type: 303/DIN Order no. 5102154 Pipe clip Hot-dip galvanised steel, to DIN 48818, Form D, width 40 mm with hole = 11 mm, prefitted with M8 x 25 screws (slotted) and M8 nuts, for pipe diameter 2 = 60.3 mm Supply and install Type: 303/DIN Order no. 5102197 Connection clamp Hot-dip galvanised steel with intermediate plate to connect Rd 8-10 round conductor or strap conductor up to FL 40 to earthing rods (deep earthing rods) with a diameter of 20 mm, prefitted with screws (slotted) and nuts Supply and install Type: 2760/20 Order no. 5001641 Connection clamp Stainless steel, material 1.4301 with intermediate plate to connect Rd 8-10 mm round conductor or strap conductor up to 4 x 40 mm to earthing rods (deep earthing rods) with a diameter of 20 mm, prefitted with screws (slotted) and nuts Supply and install Type: 2760/B-20-VA Order no. 5001625 Earthing rod To DIN 48852, Form Z, hot-dip galvanised steel, zinc coating at least 60 mm, BP system with pin and bore as coupling, diameter 20 mm Length supplied 1500 mm Supply and install Type: 219/20 BP Order no. 5000947 Earthing rod To DIN 48852, Form Z, hot-dip galvanised steel, zinc coating at least 60 mm, OMEX system with pin and bore as coupling, diameter 20 mm Length supplied 1500 mm Supply and install Type: 219/20 Order no. 5000017
20
Driving pins (to DIN 48852) of malleable cast iron Form Sp for deep earthing rods = 20 mm, OMEX system Supply and install Type: 1819/20BP Order no. 3041204 Spacer Hot-dip galvanised steel for professional installation of 10 mm round steel or 30 x 3.5 mm flat steel foundation earth, length 250 mm with depth stop Supply and install Type: 1811 Order no. 5014018 Wedge connector Hot-dip galvanised steel to DIN 48834 Form A, suitable for cross, longitudinal and T connections in the foundations, for Rd 10 round steel or 30 x 3.5 mm flat steel Supply and install Type: 1813DIN Order no. 5014212 Connecting and bridging component Aluminium, to DIN 48841 Form B, to connect round and strap conductors to steel and sheet metal structures. Connection hole = 11 mm; 5 fixing holes = 4.2 mm and 2 fixing holes = 6.9 mm on each side Supply and install Type: 288/DIN Order no. 5320712 Connecting component Aluminium, to DIN 48841 Form L, to connect round and strap conductors to steel and sheet metal structures. Connection hole = 11 mm; 5 fixing holes = 4.2 mm and 2 fixing holes = 6.9 mm Supply and install Type: 287 Order no. 5320704 Saddle terminal Hot-dip galvanised steel, to connect Rd 8-10 round conductors to sheet metal and steel structures up to 10 mm thick, with 2 hexagon head screws for clamping and 2 hexagon head screws on the crossbar, M6 (slotted) Capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 270 Order no. 5317207 Saddle terminal Hot-dip galvanised steel, for parallel and cross connection of 8-10 mm round conductors to sheet metal and steel structures up to 10 mm thick Capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 274 Order no. 5317207
17
21
18
22
23
18
24
19
25
19
25 19
Earthing rod To DIN 48852, Form Z, stainless-steel V4A, material 1.4571, BP system with pin and bore as coupling, diameter 20 mm. Length supplied 1500 mm Supply and install Type: 219/20 BP-VA Order no. 5000866 Driving pins (to DIN 48852) of malleable cast iron Form Sp for deep earthing rods = 20 mm, BP system Supply and install Type: 1819/20BP Order no. 3041212
20
22
Blitzschutz--Bauteile_GB_V0_2009200
26
Roof cable holder (to DIN 48829) of plastic, Form B1, for the installation of lightning conductor cables on flat roofs, for Rd 8 round conductor, with frost-resistant concrete filling, fill weight 1 kg. Sheath of polyethylene, floor of polypropylene, black, UV resistant Supply and install Type: 165/MBG Order no. 5217428 Roof cable holder (to DIN 48829) of plastic, Form B1, for the installation of lightning conductor cables on flat roofs, for Rd 10 round conductor, with frost-resistant concrete filling, fill weight 1 kg, black, UV resistant Supply and install Type: 165/MBG Order no. 5218675 Stand Frost-resistant concrete, with lower part of plastic M16 female thread to accept lightning rod up to 1 metre long Weight 6.9 kg each Supply and install Type: 101/St Order no. 5402891 Stand Frost-resistant concrete, M16 female thread to accept lightning rod up to 2.5 metres long Weight 16 kg each Supply and install Type: 101/B-16 Order no. 5402956
29
Anti-corrosion bandages Of cotton fabric with petroleum jelly, to be wrapped around clamping and connection points in the ground for protection; 1.2 mm thick and 50 mm wide Supply and install Type: 356 Order no. 2360055 Connector (to DIN 48837), Form A, screw of hot-dip galvanised steel, clamp part of die-cast zinc, as connection component for Rd 8-10 round conductor, capable of carrying lightning current (10/350) to EN 50164-1, 100 kA (H) Supply and install Type: 5001/DIN Order no. 5304105 Screwless cable holder Polyamide, for the installation of Rd 8-10 round conductors, with M8 female thread and through hole for woodscrews, weather and temperature resistant from -35C to +90C, mounting height 20 mm Supply and install Type: 177/20-DIN Order no. 5207444 Screwless cable holder Polyamide, for the installation of Rd 8-10 round conductors, with M8 female thread and through hole for woodscrews, weather and temperature resistant from -35C to +90C, mounting height 30 mm Supply and install Type: 177/30-DIN Order no. 5207460 Screwless cable holder Polyamide, for the installation of Rd 8-10 round conductors, with M8 female thread and through hole for woodscrews, weather and temperature resistant from -35C to +90C, mounting height 20 mm, prefitted with 5 x 60 mm woodscrew and 8 x 40 mm plastic plug Supply and install Type: 177/B-HD-20 Order no. 5207851 Screwless cable holder Polyamide, for the installation of Rd 8-10 round conductors, with M8 female thread and through hole for woodscrews, weather and temperature resistant from -35C to +90C, mounting height 30 mm, prefitted with 5 x 60 mm woodscrew and 8 x 40 mm plastic plug Supply and install Type: 177/B-HD-30 Order no. 5207878 Expansion piece Aluminium, to compensate for changes of length due to temperature variations on the roof with conductor lengths of more than 20 metres. Length about 400 mm, Rd 8 round conductor Supply and install Type: 172/AR Order no. 5218926 Jumper cable (to DIN 48841 Form D), steel, to bridge expansion gaps and butt joints, steel cable 25 mm2, black plastic covering, with aluminium cable lugs, 1 fixing hole = 8.5 mm and 2 fixing holes = 4.2 mm Supply and install Type: 853/DIN Order no. 5331013
30
26
31
27
31
27
31 28
Lightning rod (to DIN 48802 Form A1) aluminium, diameter 16 mm, with M16 x 35 thread to screw into stand with M16 female thread, length 1000 mm Supply and install Type: 101/ALU Order no. 5401771 Lightning rod (to DIN 48802 Form A 1) aluminium, diameter 16 mm, with M16 x 35 thread to screw into stand with M16 female thread, length 1500 mm Supply and install Type: 101/ALU Order no. 5401801 Lightning rod (to DIN 48802 Form A1) aluminium, diameter 16 mm, with M16 x 35 thread to screw into stand with M16 female thread, length 2000 mm Supply and install Type: 101/ALU Order no. 5401836 Lightning rod (to DIN 48802 Form A1) aluminium, diameter 16 mm, with M16 x 35 thread to screw into stand with M16 female thread, length 2500 mm Supply and install Type: 101/ALU Order no. 5401852 Lightning rod (to DIN 48802 Form A1) aluminium, diameter 16 mm, with M16 x 35 thread to screw into stand with M16 female thread, length 3000 mm Supply and install Type: 101/ALU Order no. 5401879
28
31
28
32
28
33
Blitzschutz--Bauteile_GB_V0_2009200
28
23
34
Lightning arrester Requirement class B to E DIN VDE 0675 Part 6 (A1/A2) Multiple spark gap without blow-out, no plasma arcs produced outside the casing With VDE, VE, KEMA KEUR approval marks, single-pole Rated/design voltage 230 V/ 255 V 50-60 Hz Lightning current discharge cap. 50 kA (10/350) Protection level < 2 kV Mains follow-up current quenching 25 kA Max. required series fuse 500 A Plug-in upper part allows insulation resistance to be chekked without interrupting the voltage (TAB guideline), fully enclosed spark gap, snap fits to EN 50022 top-hat rail 2 connection possibilities each for L and N/PE conductors Make: OBO Bettermann Type: MC 50-B VDE Order no. 5096847 or equivalent NPE sum current spark gap Requirement class B to E DIN VDE 0675 Part 6 (A1/A2), for use between neutral conductor (N) and protective earth conductor (PE) to DIN VDE 100 Part 534, single-pole Rated/design voltage 230 V/ 255 V 50-60 Hz Lightning current discharge cap. 125 kA (10/350) Protection level < 2.5 kV Fully enclosed spark gap, snap fits to EN 50022 top-hat rail 2 connection possibilities each for N and PE conductors Make: OBO Bettermann Type: MC 125-B/NPE Order no. 5096863 or equivalent Lightning arrester Requirement class B to E DIN VDE 0675 Part 6 (A1/A2), for use in lightning protection potential equalisation to DIN VDE 0185 Part 1/100, triple-pole Rated/design voltage 230 V/ 275 V 50-60 Hz Tot. disch. surge current (nom.) 75 kA (8/20) Limit disch. surge current (3-pole) 150 kA (8/20) Protection level < 2 kV Max. required series fuse 160 A The arrester is in two parts arrester module and base The arrester module can be separated from the base without tools. It snap-fits to top-hat rail to EN 50022 Optical function indication Make: OBO Bettermann Type: V 25-B/3 Order no. 5097002 or equivalent
35
Lightning arrester Requirement class B to E DIN VDE 0675 Part 6 (A1/A2), for use in lightning protection potential equalisation to DIN VDE 0185 Part 1/100, four-pole Rated/design voltage 230 V/ 275 V 50-60 Hz Tot. disch. surge current (nom.) 100 kA (8/20) Limit disch. surge current (4-pole) 200 kA (8/20) Protection level < 2 kV Max. required series fuse 160 A The arrester is in two parts - arrester module and base The arrester module can be separated from the base without tools. It snap fits to top-hat rail to EN 50022 Optical function indication Make: OBO Bettermann Type: V 25-B/4 Order no. 5097037 or equivalent Lightning arrester Universally suitable for TN-S, IT and TT systems, of requirement class B to E DIN VDE 0675 Part 6 (A1/A2), for use in lightning protection potential equalisation to DIN VDE 0185 Part 1/100, four-pole arrester (3 lightning arresters + NPE spark gap) Lightning arresters (triple-pole) Rated/design voltage 230 V/ 275 V 50-60 Hz Total disch. surge current (nom.) 75 kA (8/20) Limit disch. surge current (3-pole) 150 kA (8/20) Protection level < 2 kV Max. required series fuse 160 A NPE spark gap (single-pole) Rated/design voltage 230 V/ 255 V 50-60Hz Nominal discharge surge current 50 kA (8/20) The arrester is in two parts arrester module and base The arrester module can be separated from the base without tools. It snap fits to top-hat rail to EN 50022 Optical function indication Make: OBO Bettermann Type: V 25-B/3+NPE Order no. 5097401 or equivalent Lightning arrester Requirement class B to E DIN VDE 0675 Part 6 (A1/A2), for use in lightning protection potential equalisation to DIN VDE 0185 Part 1/100 Upper part Rated/design voltage 230 V/ 275 V 50-60 Hz Nominal discharge surge current 30 kA (8/20) Limit discharge surge current 60 kA (8/20) Protection level < 2 kV Max. required series fuse 160 A Upper part for use in arrester base, optical function indication Make: OBO Bettermann Type: V 25-B/0 Order no. 5097053 or equivalent
35
34
34
35
24
Blitzschutz--Bauteile_GB_V0_2009200
25
Done by:
General information
Owner, name Street Postcode, town I Type of roof covering (number) yes DIN VDE 0185-1 VDE V 0185-100 Building-related test Repeat test Visual check In accordance with the standards no - Shortcomings: see test result II III IV
Nature of test
Test of planning Acceptance test Supplementary test Complete test -
- loose connections - parts weakened by corrosion - all earth connections - fixings of all conductors and system components - changes that require additional protection measures - correct installation of all lightning and surge arresters
Measurements
- continuity of connections that are out of sight - lightning collectors - lightning conductors - potential equalisation lines (guideline value 1 ohm) - measurement of the contact resistance at all measurement points, in order to determine the continuity of the lines (guideline value 1 ohm) - continuity to metallic installations (gas, water, heating, ventilation, etc.) -
Test joint no. RA in ohms Test joint no. RA in ohms Test joint no. RA in ohms
1 10 19
2 11 20
3 12 21
4 13 22
5 14 23
6 15 24
7 16 25
8 17 26
9 18 27
Propagation resistance RA tot of the entire installation __________Ohm with test joints closed visual check by excavation yes no - Position
Test result
The lightning protection system is satisfactory: The test revealed the following shortcomings: yes no -
Next test due The test report contains pages The test report contains annexes
Place
, date:
Signature of tester
Signature of owner
EAN
Order no.
Price Page EAN E 17 5417675 5417736 15 5417910 15 5418092 15 5418153 15 15 5419471 15 5925873 15
Order no.
Order no.
Price Page
5230533 2360055 5242710 3041204 5242772 3041212 5371298 5000017 5371830 5000866 5371892 5000947 5752653 5001625 5372912 5001641 5377894 5014018 5378013 5014212 5378259 5015073 5959427 5015111 5378556 5015650 5800415 5018501 5800477 5018706 5380832 5020336 5381372 5020832 5381495 5020956 5901273 5021294 5966388 5096847 5966449 5096863 5808091 5394037 5394099 5785590 5399919 5399971 5400035 5400097 5400158 5097002 5097037 5097053 5097401 5102081 5102111 5102138 5102154 5102197
15 5419891 5316014 16 5818359 5316170 14 5420552 5317207 14 5420859 5317428 14 5421573 5320704 14 5421634 5320712 14 5422419 5326303 14 5422471 5326311 14 14 5423379 5331013 12 5423614 5335205 G 5424215 5336007 18 5424277 5336023 18 5424338 5336058 18 5426790 5350867 18 5426912 5350905 18 18 5426974 5351057 5427032 5351073 15 15 15 15 15 5901334 5427810 5427872 5898399 5902119 5401771 5401801 5401836 5401852 5401879
5403036 5202515 5902232 5202590 5404897 5404958 5336433 5334811 5811879 5902591 5812296 5812418 5207444 5207460 5207851 5207878 5215374 5215544 5215587 5215609
12 5428053 5402107 12 5428176 5402158 5428534 5402891 17 5897910 5402956 17 17 5429616 5412609 17 5752356 5412803 12 5429791 5420156 12 5429913 5420202 12 12 16 16 17 13 13 E 17
28
Blitzschutz--- Bauteile_GB_V0_2009200
29
Type 101/ALU 101/ALU 101/ALU 101/ALU 101/ALU 101/B-16 101/G-DIN 101/G-DIN 101/ST 113/B-Z-HD 8-10 113/B-Z-HD-16 113/Z 8-10 113/Z-16 132/K-Cu 132/K-VA 157/FK-VA 157/FK-VA 157/FK-VA 157/LK-VA 165/MBG 165/MBG 172/AR 177/20-DIN 177/30-DIN 177/B-HD-20 177/B-HD-30 200 200 219/20 219/20 BP 219/20 BP-VA 223/DIN 226 226/Cu 226/VA 248/VA 249/Alu 249/ST 252/DIN 252/DIN 256/A-DIN 256/B-A-DIN 30 262 262/ZM 270 274 287 30
Dimensions 1000 Alu 1500 Alu 2000 Alu 2500 Alu 3000 Alu
EAN
Order no. 5401771 5401801 5401836 5401852 5401879 5402956 5402107 5402158 5402891 5230322 5412803 5229960 5412609
Price B
Page 17 17 17 17 17 16 12 12 16 13 14 13 13 12 12 12 12 12 12 16 16 17 17 17 17 17 14 14
Type 288/DIN 301/S 301/S 301/V 301/V-VA 303/DIN 303/DIN 303/DIN 303/DIN 303/DIN 324/S 324/S-VA 356 853/DIN 1801 VDE 1809 1809/A 1811 1813/DIN 1819/20 1819/20BP 2760/20 2760/20-VA 5001/DIN 5052 5052 5052 5052/V2A 5052/V4A MC 50-B VDE MC 125-B/NPE RD 8/ALU-T** V 25-B/0 V 25-B/3 (TN-C) V 25-B/3+NPE V 25-B/4 (TN-S)
Dimensions
EAN
Order no.
Price B
Page 16 13 13 13 13 15 15 15 15 15 13 13
5901334 5427810 5427872 5898399 5902119 5897910 1000 FT 5428053 1500 FT 5428176 5428534 Rd 8-10 Rd 16 Rd 8-10 Rd 16 5629535 5752356 5412212 5429616
Alu 5421634 5320712 5426974 5427032 5426790 5426912 FT FT FT FT FT 5399919 5399971 5400035 5400097 5400158 5351057 5351073 5350867 5350905 5102081 5102111 5102138 5102154 5102197
Rd 8-10 5902232 5202590 Rd 8-10 5403036 5202515 Rd 8-10 Rd 8-10 Rd 8-10 Rd 8-10 5902591 5812296 5812418 5811879 5215544 5215587 5215609 5215374
5422419 5326303 5422471 5326311 10 5230533 2360055 Alu 5423379 5331013 5378556 5015650 5378259 5959427 5377894 5378013 5242710 5242772 5015073 5015111 5014018 5014212 3041204 3041212 E B E
17 17 14 14 14 15 16 15 15 15 15 17 14 14 14 14 14
Rd 10 PE/PP 5408734 5218675 Rd 8 PE/PP 5408857 5218691 Alu 5409090 5218926 Rd 8-10 PA Rd 8-10 PA Rd 8-10 PA Rd 8-10 PA 5404897 5404958 5336433 5334811 5207444 5207460 5207851 5207878
250 FT FT TG TG
1500 FT 5429791 5420156 2000 FT 5429913 5420202 1500 5371298 5000017 1500 5371892 5000947 1500 5371830 5000866 8-10/16 5423614 5335205 8-10/FL30 x 16 5424215 5336007 8-10/FL30 x 16 5424277 5336023 8-10/FL30 x 16 5424338 5336058 Rd 8-10 5417910 5311551 Rd 8-10 5417736 5311519 Rd 8-10 5417675 5311500 5418153 5312345 5418092 5312310 5419471 5314658 5925873 5314720 5419891 5316014 5818359 5420552 5420859 5421573 5316170 5317207 5317428 5320704 E E
5372912 5001641 5752653 5001625 Rd 8-10 5415879 5304105 FT FT FT V2A V4A 5380832 5381372 5381495 5800415 5800477 5020336 5020832 5020956 5018501 5018706 G
15 15 15 13 13 13 13 12 12 12 14 14 14 14 12 12 16 16 16
5966388 5096847 5966449 5096863 5901273 5021294 5394099 5808091 5785590 5394037 5097053 5097002 5097401 5097037
18 18 12 18 18 18 18
E G
Blitzschutz--- Bauteile_GB_V0_2009200
31
Discount groups
B E G
Lightning protection components
32
OBO BETTERMANN GmbH & Co. KG and OBO BETTERMANN Projekt und Systemtechnik GmbH, Menden
1. All our supplies and services shall be governed exclusively by the following terms and conditions, including our additional terms and conditions for cable tray business transactions. Any terms and conditions of business and purchasing of the customer shall be valid only if we have acknowledged them in writing. Our quotations are without engagement; they are mere invitations to submit contract offers. Any and all transactions and agreements, including those entered into by our employees and agents shall only be binding upon our written confirmation or invoicing. The foregoing provision shall also apply to any modifications of the agreed formal requirements. 2. The documents and data pertaining to the quotation, such as illustrations, brochures, drawings, dimensions, loading capacity values and weight details are approximate only, unless they are expressly stipulated to be binding. Samples are non-binding samples for inspection. Any purchase according to sample will be subject to customary deviations and deviations resulting from normal production processes. The properties of the sample shall be no guaranteed quality of the purchase object unless expressly stated otherwise in the confirmation of order. Samples must be returned to us at the latest within four weeks in perfect condition. If they are not returned within this period in proper condition,we shall be entitled to charge the purchase price for the sample in accordance with our currentprice list. All information on our products, in particular the illustrations, drawings, weight, dimension and performance data included in our quotations and printed matter shall be regarded as approximate average values and shall not represent any quality guarantee. With regard to products made according to customer drawings, samples and other instructions of the customer, we will not provide any warranty nor assume any liability for the due and proper functioning of the product or for any other defects if and to the extent they are based upon the customers specifications. The customer shall indemnify us from any third party claims, including claims for product liability as may be asserted against us for damages resulting from the products unless we have caused such damages by intent or gross negligence. The customer shall warrant that the manufacture and supply of products made in accordance with his instructions will not infringe any proprietary rights of third parties. Should any proprietary rights be asserted against us, we shall be entitled, without any legal review of the third party claims, to withdraw from the contract after hearing the customer, unless the third party withdraws the claims asserted against us under its proprietary rights within eight days by written declaration. The customer shall compensate us for any damage sustained as a result of the assertion of proprietary rights. In case of withdrawal, the work we have carried out so far shall be remunerated. Further rights under the statutory provisions shall not be affected thereby. Any moulds, tools and design data produced by us for the execution of the order shall be our exclusive property. Unless expressly agreed otherwise, the customer shall not have any claims thereto, even if he has contributed to the costs of producing any such moulds, tools and design data. 3. The packing, shipping route and means of transportation shall be left to our discretion in the absence of any other agreements. They shall be charged at their cost price. We will take back undamaged cases, when being returned carriage paid, at 2/3 of the amount invoiced. The one-way or pool pallets used for transport shall be either exchanged upon taking delivery or returned. The smallest packing units stocked and listed may not be broken up for rationalisation reasons. In case of orders for different quantities, the nearest packing unit will be supplied. We reserve the right to deviate from the agreed delivery quantity, in particular in the case of custom-made products, to a customary extent or in conformity with national or international standards. In case of a demand for adhering to a precise quantity, an express reference is necessary and subject to confirmation. Master and call orders shall oblige the customer to accept the total quantity on which the master/call order is based. Where no particular call orders are specified in the contract, the total quantity of the master call order must be called within twelve months. If the customer fails to adhere to call deadlines, we shall be entitled to deliver and charge the total quantity in full after four weeks from written notice with reference to the consequences of any failure to call. Our rights arising from any default of the customer shall not be affected thereby. 4. Unless otherwise agreed, our prices are quoted ex works and do not include packing and insurance. The value added tax at the rate applicable on the date of dispatch will be added to our prices. The purchaser shall ensure the correctness of his VAT identification number, which he must notify to us immediately without being asked. He shall undertake to inform both us and the competent domestic tax authority without delay of any change in his name, address and VAT identification number. Delivery shall be franco domicile within Germany, i.e. carriage and packing prepaid, if the net order value is in excess of 1,200. For small orders below 100 (net excluding value added tax), we shall invoice a lower quantity surcharge of 10 (net) per order. Upon transfer of our supplies and services to a carrier or forwarding agent, at the latest upon their leaving our warehouse or supply plant, the risk shall pass to the recipient, even in case of deliveries free place of destination. 5. Delivery periods and delivery deadlines shall be approximate only unless we have expressly stated in writing that they are binding. Delivery periods shall commence upon receipt of our confirmation of order, but not before clarification of all execution details, ex place of delivery. The customer shall only be entitled to withdraw from the contract after having granted a reasonable extension of time. We reserve the right to make partial deliveries. Claims for damages and reimbursement ofexpenses -- for any reason whatsoever -- shallbe subjectto the provisions setout in article 10. In the event of any circumstances that are beyond our control within the scope of normal operating risks and obstruct or make impracticable any delivery, we shall be entitled to suspend delivery by the duration of such obstruction plus a reasonable start-up period or to withdraw from the contract for the part not yet fulfilled. The purchaser can demand a statement from us as to whether we wish to deliver within a reasonable period or withdraw. If we fail to make such a statement, the purchaser may withdraw. Our notice to the purchaser shall be deemed to be sufficient evidence that we have been prevented from delivering. 6. Payments shall be made upon receipt of invoice less a 3% cash discount for payment within 10 days or net after 30 days from date of invoice. Erection work and all paid labour work must be paid within 10 days without deduction of any cash discount. In case of non-cash payments, the date of the credit note will be deemed to be the date of receipt ofpayment.Payments received shallalways be credited firstagainst costs,then againstinterest and then againstthe earliest liability. Cheques and bills of exchange shall only be accepted as means of payment. Any payment by bill of exchange shall be subject to a prior separate and written agreement, whereby all bill costs shall be borne by the customer and no discount can be granted. The customer shall have no right to refuse performance and no right of retention -- for any legal reason whatsoever -- unless we have acknowledged his claim beforehand in writing or his claim has the force of law. The customer shall only be entitled to set off claims which have the force of law, are undisputed or acknowledged by us in writing. 7. We shallretain title to the goods supplied by us until allour claims arising fromour business transactions with the customer have been satisfied -- current account clause -- and all bills of exchange or cheques submitted for payment by the customer have been honoured. Any treatmentor processing ofgoods subjectto our retention oftitle (reserved goods) shallbe carried out for us as the manufacturer in accordance with 950 BGB (German Civil Code) without any obligation on our part. If our reserved goods are to be regarded as the main item or the main item is owned by the customer, full title to the new item shall pass to us when it is created. In other cases,we shallacquire a co-ownership interestin the new itemin the proportion of the sales value of our reserved goods to the other goods used for the new item at the time of processing, intermingling, joining or mixing. The customer shall take custody of our ownership or co-ownership interest free of charge; it shall be treated as reserved goods. Before transfer of title, our goods shall be neither pledged nor assigned as collateral without our prior consent. In addition, any third party rights or pledges shall be notified to us immediately and we shall be given all details and provided all documents necessary for intervention; otherwise the customer must bear our loss. In the latter case, our total claims against the customer shall also be immediately payable. The customer shall be entitled to sell or to use our reserved goods in the ordinary course of business subject to the condition that the relevant claims are transferred in accordance with article 8 below. This right shall lapse upon the customers failure to promptly meet his payment obligations towards us or in the event of any cheque or bill protests or his suspension of payments. In such cases, we shall be entitled to take back the goods provisionally at the customers expense and to sellthematour duly exercised discretion after a corresponding reminder has been sentto the customer. We will then pass the due amount to the customers credit. 8. If our goods are sold before payment of our claim, the customer shall be obliged to retain our title against his purchaser until the goods have been paid for in full by the purchaser. The claim arising against the purchaser from such resale as well as any other ancillary rights or security interests of the customer resulting from the sale and any claims for compensation in case of damage to or destruction of our reserved property, including the relevant insurance sum shall hereby be assigned to us. We hereby accept this assignment. Where our co-ownership interest is sold, the relevant claims shall be assigned in the amount corresponding to the value of our interest. The customer shall, at our request, inform us of his purchasers, notify them of the assignment made and provide us with any and all documents required to assert our rights. As long as the customer meets his contractual obligations without delay, he shall be authorised to collect the claims assigned. He shall keep the amounts collected on our behalf separately and remit them to us immediately as soon and as far as our claims become due. The authorisation shall lapse in case of any cheque or bill protest of the customer or his definite suspension of payments. The customer shall bear the costs incurred for any action taken against third parties and shall advance them upon request. If the security provided to us by the retention of title and the anticipatory assignment should exceed the claims to be secured by more than 20%,we shall,atthe customers request,release paid supplies ofour choice.Upon paymentof all our claims by the customer, assigned claims shall pass to the customer. 9. Any complaints for obvious defects regarding the quantity or quality of our supplies and services that are identifiable upon careful inspection shall without delay, but at the latest within the period of limitation of eight days from arrival of the goods at the address of the customer or the person appointed by him,be notified in writing to us,not to our representatives. Slight deviations in dimensions and designs within the scope of defined technical tolerances shall not give rise to any right of complaint. Any rejected goods may only be returned to us with our prior written authorisation. In case of justified complaints within the prescribed period, we shall, at our option, take remedial action by way of subsequent performance, by rectifying the defect, supplying non-defective goods or providing a credit note for the lower value calculated. We shall be entitled to refuse subsequent performance in accordance with the statutory provisions. If we refuse subsequent performance, if any subsequent performance remains unsuccessful or if the customer cannot be reasonably expected to acceptany subsequentperformance, the latter shallbe entitled to withdraw from the contract in compliance with the provisions of the following sentences. The customer shall only be entitled to withdraw fromthe contract -- where a withdrawal is not excluded by law -- upon the unsuccessful expiry of a reasonable period for subsequent performance set by him, unless this period was not required under the statutory provisions ( 281 para. 2, 323 para. 2, 440, 441 para. 1 BGB (German Civil Code)). In case of his withdrawal, the customer shall be liable for any deterioration, destruction or loss of use resulting from any negligence or intent on his part. Any claims for damages or reimbursement of expenses of the customer shall be subject to the provisions set out in article 10. In the case of any fraudulent concealment of a defect or in the case of any provision of a quality guarantee for the goods sold at the time of the passing of risk within the meaning of 444 BGB (German Civil Code) (sellers declaration that the object sold has a specific property at the time of the passing of risk and that the seller, regardless of any fault on his part, intends to be answerable for any and all consequences resulting from its absence), the customers rights shall be exclusively governed by the statutory provisions. We shall -- in addition to the statutory grounds for refusal -- also be entitled to refuse subsequent performance if and as long as the customer fails to send us, at our request, the rejected goods or a sample thereof; the customer shall have no right of withdrawal for any such refusal. We may further refuse any subsequent performance if the goods concerned have been altered or modified without our consent unless the customer can prove that the defect was not caused by such alteration or modification. The limitation period for any claims arising from defects shall be one year;in the case ofgoods which have been used in accordance with their intended purpose for a building and have caused its defectiveness, the limitation period shall be two years. The provisions of 478, 479 BGB (German Civil Code) on recourse in the chain of suppliers shall not be affected thereby. 10. In the case ofa pre-contractual,contractual or non-contractual breach of duty,including unsatisfactory delivery, tortious conduct and producers liability, we shall only be liable for compensatory damages and reimbursement of expenses -- subject to further contractualor statutory liability requirements -- in the case of intent,gross negligence or slightly negligent breach of a material contractual duty (contractual duty the infringement of which jeopardises the fulfilment of the object of the contract). However -- except in the case of intent -- our liability shall be limited to the typicalcontractualdamage thatwas foreseeable at the time the contract was entered into.The purchaser shall notbe permitted to make a claim for expenses incurred in vain. Except for any breach of material duties, our liability for slight negligence shall be excluded, but in any case be limited to the amount of the purchase price. Any claim asserted by the customer or a third party for payment of a contractual penalty shall be excluded. With regard to damages caused by delay, we shall only be liable for slight negligence up to the amount of 5% of the purchase price agreed with us. The exclusions and limitations of liability set forth above shall not apply in the event that a guarantee is given with respect to the quality of the object sold within the meaning of 444 BGB (German Civil Code) if a defect is fraudulently concealed or in the event of injury to life, physical injury or injury to health, or strict liability under the German Product Liability Act. Any and all claims for damages against us,for any legal reason whatsoever, shallbecome statute-barred at the latest after one year from delivery of the goods to the customer, in the case of tortious liability from the time of knowledge, or grossly negligent ignorance, of the circumstances giving rise to the claim and the person liable to pay damages. This provision shall not apply in the case of liability for intent and in the event that a guarantee is given for the quality of the object sold, in the case of fraudulent concealment of a defect or in the event of injury to life, physical injury or injury to health, or strict liability under the German Product Liability Act. Any shorter limitation periods shall take precedence. 11. We shall be entitled to process and store any customer data obtained with regard to or in connection with the business relationship in accordance with the German Federal Data Protection Act,irrespective ofwhether such data is provided by the purchaser himself or by any third parties. 12. Place of performance for delivery and payment is Menden/Sauerland. The court of competent jurisdiction for any and alldisputes,including disputes with regard to bills ofexchange and cheques,is the Local Court(Amtsgericht) of Menden or, at our option, the District Court (Landgericht) of Arnsberg, irrespective of the value of the object in dispute. We shall, however, also be entitled to take legal proceedings against the customer at the place of his registered office. German law shall be exclusively applicable. The application of international purchase laws is hereby excluded. Should, for any reason whatsoever, individual provisions of our terms and conditions of sale and delivery be invalid, the validity and binding nature of the other provisions shall not be affected thereby. The customer agrees that the invalid provision shall be replaced by a valid provision that comes as close as possible to the economic meaning of the invalid provision. 13. The prices of products made of brass and copper are subject to certain fluctuations that are based on the relevant DEL listings. The prices of our brass articles are based on a DEL listing of 150 for Ms 58, those of our copper products on a DEL value for electrolyte copper of 200. In case of any increase or reduction in these prices by more than 15, a five per cent surcharge or deduction shall be made for each 15 points. The calculation of any such surcharges or deductions shall be based on the DEL listing of the date of our receipt of the order. Valid from April 2002
OBO-System overview
VBS Connection and fastening systems
Connection systems Fastening systems Beam clamp systems Rail systems Screw-in and knock-in systems
Earthing systems Equipotential bonding systems Lightning protection systems Surge protection systems
Installation systems Cable tray systems Mesh cable tray systems Cable ladder systems Vertical ladder systems Lighting support systems Modular systems Distribution boxes Stainless steel components