Cleanouts
Exclusive Features
Round or square extra heavy-duty covers available for traffic loads.
WADE
Non-skid cover with frame secured to adjustable housing.
Snap lock for adjustable housing.
Optional brass plug with neoprene gasket seal permits easy removal-118.
Anchor flange.
Two-piece threaded adjustable housing insures true floor level installation.
Ty-Seal hub outlet for No-Hub or SV connection (spigot outlet and inside caulk available).
Vandal-proof screws standard on all nickel-bronze tops; security screws optional.
Low Position
High Position
Suffixes and Options To select a cleanout with a standard plug, SV Ty-Seal hub outlet, 4" size, top to be nickel bronze:
6004TY, 1
ADJUSTABLE CO (600)
5-15-2000 Cleanouts
4"SIZE (4)
TY-SEAL HUB (TY)
NICKEL BRONZE TOP (1)
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-1
Cleanouts
Installation Details
WADE
6000IC, Z Inside Caulk - used with lead and oakum. Adjustable floor cleanout installed in unfinished floor slab. Adjustable housing with special duty cover is designed for heavy traffic areas.
6000NH Spigot Outlet - inserted in SV TySeal Hub. Adjustable floor cleanout installed in typical waterproof floor slab. Adjustable housing provides for variations in floor fill.
6000NH Spigot Outlet - used with No-Hub coupling. Adjustable floor cleanout installed in finished floor. Adjustable housing permits flush-with-floor installation.
6000TY Hub Outlet - with gasket, accepts No-Hub and SV pipe. Adjustable floor cleanout is installed in finished floor. Adjustable housing permits flush-with-floor installation.
7-2
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Cleanout Tops
Optional Tops
WADE
Cleanout Selection 1. Select the type of ferrule required. 2. Select the adjustable top assembly required for the type of floor and traffic conditions. A. If the Standard Round Top is desired, specify the entire cleanout using the ferrule size and type. Example: 6004NH, 1. B. To specify any top other than Standard Round, add the letter designation of the top to the ferrule assembly required. Example: A 6004IC ferrule with a Type Z top should be specified as 6004Z, IC. NOTE: Cleanouts for finished floor areas should be specified with nickel bronze tops. For unfinished floors or exterior use, specify cast iron tops.
CARPET FLANGE (CF) ANSI Load Class - Light Duty (Under 2,000 lbs.)
CARPET MARKER (CM)
SYNTHETIC COVERING (D) Adds 3/8" To Min. and Max. Vertical Adjustment ANSI Load Class - Heavy Duty (5,000 to 7,499 lbs.)
TILE TOP (T) ROUND (TS) SQUARE Adds 3/8" To Min. and Max. Vertical Adjustment ANSI Load Class - Light Duty (Under 2,000 lbs.)
HEAVY-DUTY TOP (X) ROUND (XS) SQUARE Adds 3/8" To Min. and Max. Vertical Adjustment ANSI Load Class - Heavy Duty (5,000 to 7,499 lbs.)
5-15-2000 Cleanouts
TERRAZZO TOP (U) ROUND (US) SQUARE Adds 3/8" To Min. and Max. Vertical Adjustment ANSI Load Class - Light Duty (Under 2,000 lbs.)
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-3
Minimum Cleanout Requirements
The following excerpts from the National Plumbing Code concerning minimum cleanout requirements are listed for reference, but clarification and enlargement in specifications is recommended. Location: Cleanouts shall be not more than fifty feet apart in horizontal drainage lines of four inch nominal diameter or less, and not more than 100 feet apart for larger pipes. Change of direction: Cleanouts shall be installed at each change of direction of the building drain greater than 45. Base of stacks: A cleanout shall be provided at or near the foot of each vertical waste or soil stack. For buildings with a floor slab on fill or ground, or with less than 18- inch crawl space under the floor, the following will be acceptable instead of a cleanout at the base of the stack. The building drain may be extended to the outside of the building and terminated in an accessible cleanout, or an accessible cleanout installed in the building drain downstream from the stack not more than five feet outside the building wall. Underground drainage: Cleanouts, when installed on an underground drain, shall be extended to or above the finished grade level directly above the place where the cleanout is installed. Concealed piping: Cleanouts on concealed piping shall be extended through and terminate flush with the finished wall or floor. Size of Cleanouts Small pipes: Cleanouts shall be of the same nominal size as the pipes up to four inches, and not less than four inches for larger piping. Large pipes: For underground piping over ten inches, manholes shall be provided and located at each 90 change in direction, and at intervals of not more than 150 feet. Cleanout Clearances Small pipes: Cleanouts smaller than three inches shall be installed with a 12-inch clearance for rodding. Large Pipes: Cleanouts on three inch or larger pipes shall be installed with a clearance of not less than 18inches for rodding. Caulking: Cement, plaster or any other permanent finishing material shall not be placed over a cleanout plug. Concealment: Where it is necessary to conceal a cleanout plug, a covering plate or access door shall be provided which will permit ready access to the plug. The above excerpts cover only minimum requirements.
WADE
For improved cleanout installations the following suggestions are submitted. Unfinished floor areas: Floor cleanouts shall have a cast iron cover and be designed sufficiently strong for the traffic expected. Finished floor areas: Consideration should be give to the type and pattern of the finished floor area. Round cleanout covers are recommended for terrazzo floor and square covers for tile floors. Nonferrous covers and frames of nickel bronze should be used to give the floor area a finished appearance. Finished walls: Cleanouts in or behind walls should have an access cover and frame embedded flush with the finished wall. The cover shall be smooth nickel bronze of ample size to provide a clear access to the cleanout. Vandalism: Access and cleanout cover should be secured with vandal-proof screws where these units are accessible and apt to be removed.
7-4
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Floor Cleanouts
6000 (SV Hub Outlet, Spigot Outlet, Inside Caulk)
Cast iron cleanout with threaded adjustable housing, flanged ferrule and round secured nickel bronze top. ANSI Load Class (Standard Top) Light Duty (Under 2,000 lbs)
WADE
TOP VARIATIONS
Cat. No. Pipe Size B Wt. Lbs. Suffix Description ANSI Load Class
OPTIONS
Suffix Description
6002,1 6003,1 6004,1 6005,1 6006,1 OUTLET
Suffix
2 3 4 5 6
2 1/ 2 2 3/ 4 3 3 3
16 17 18 19 21
Description
TY ... Ty-Seal NH .. No-Hub IC .... Inside Caulk (2", 3", 4")
5-15-2000 Cleanouts
CF .... Carpet Flange ........... (LD) CM ... Carpet Marker D ...... Wide Flange ............ (HD) S ...... Standard Square Top T ...... Tile Top ..................... (LD) TS .... Square Tile Top ........ (LD) U...... Terrazzo ................... (LD) US .... Square Terrazzo ........ (LD) X ...... Heavy Duty Top XS .... Square Heavy Duty Top
39 ........ Galvanized Iron Parts 75 ........ Bronze Plug 179 ...... Security Screws
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-5
Floor Cleanouts
6000Z (Spigot Outlet, Inside Caulk, SV Hub Outlet)
Cast iron cleanout with threaded adjustable housing, flanged ferrule with round scoriated cast iron or with nickel bronze veneer tractor type cover. ANSI Load Class - Special Duty (Over 10,000 lbs)
WADE
OPTIONS
Cat. No. Pipe Size B Wt. Lbs. Suffix Description
OUTLET
Suffix Description
6002Z 6003Z 6004Z 6005Z 6006Z
2 3 4 5 6
2 1/2 2 3/ 4 3 3 3
16 17 18 19 21
1 .......... Nickel Bronze Veneer 39 ........ Galvanized Iron Parts 75 ........ Bronze Plug 179 ...... Security Screws
TY ... Ty-Seal NH .. No-Hub IC .... Inside Caulk (2", 3", 4")
7-6
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Cleanout Ferrules
6000 (Spigot Outlet, Inside Caulk, SV Hub Outlet)
Cast iron cleanout with flanged ferrule .
WADE
OPTIONS
Cat. No. Pipe Size B Wt. Lbs. Suffix Description
OUTLET
Suffix Description
6002 6003 6004 6005 6006
2 3 4 5 6
2 1/ 2 2 3/ 4 3 3 3
16 17 18 19 21
39 ........ Galvanized Iron Parts 75 ........ Bronze Plug
TY ........ Ty-Seal NH ....... No-Hub IC ......... Inside Caulk (2", 3", 4")
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-7
Floor Cleanouts
8000
Cast iron cleanout with threaded adjustable housing, removable thread shield, plastic gasketed plug and round secured nickel bronze scorated top.
WADE
OUTLETS
Suffix Description
NH .......... No-Hub TY ........... Ty-Seal (Push-On) OPTIONS
Cat. No. Pipe Size Wt. Lbs. Suffix Description
8002 8003 8004
2 3 4
16.0 17.0 18.0
75 ........... Bronze Plug 179 ......... Security Screws
7-8
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Floor Cleanouts
8000Z
Cast iron cleanout with threaded adjustable housing, removable thread shield, plastic gasketed plug and round ductile iron cover w/ secured nickel bronze scoriated veneer top.
WADE
OUTLETS
Suffix Description
NH .......... No-Hub TY ........... Ty-Seal (Push-On) OPTIONS
Cat. No. Pipe Size Wt. Lbs. Suffix Description
8002 8003 8004
5-15-2000 Cleanouts
2 3 4
16.0 17.0 18.0
75 ........... Bronze Plug 179 ......... Security Screws
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-9
Floor Cleanouts
8130AF
Cast iron spigot outlet floor cleanout with tapered brass plug, threaded adjustable nickel bronze top and round secured scoriated cover. ANSI Load Class - Light Duty (under 2,000 lbs.)
WADE
OPTIONS
Cat. No. Pipe Size Wt. Lbs. E A B C D Min. Max. Suffix Description
8133AF 8134AF
3 4
5 8
2 1/2 3 1/ 2
3 3 1/4
2 3
4 1/2 5 1/4
1 3/4 1 3/8
2 1/2 2 1/8
72 ........... Carpet Marker Cover 179 ......... Security Screws
7-10
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Access Covers
8300C
Round scoriated vandal proof nickel bronze access cover and frame. ANSI Load Class - Light Duty (under 2,000 lbs.)
WADE
OPTIONS
Cat. No. B C D Wt. Lbs. Suffix Description
8300C6 8300C7 8300C10
6 7 1/ 4 10
5 1/ 2 6 3/ 4 9 1/ 2
4 1/ 2 5 3/ 4 9
3 4 7
179 ......... Security Screws
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-11
Access Housing
8300MF
Access housing with adjustable anchor flange and extra heavy secured scoriated ductile iron cover. ANSI Load Class - Special Duty (Over 10,000 lbs.)
WADE
OPTIONS
Cat. No. Wt. Lbs. Suffix Description
8300MF
35
39 ........... Galvanized Iron Parts
7-12
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Access Covers
8300S
Square 9x9-in. scoriated secured nickel bronze access cover and frame. ANSI Load Class - Light Duty (under 2,000 lbs.)
WADE
OPTIONS
Cat. No. Wt. Lbs. Suffix Description
8300-S9
179 ......... Security Screws
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-13
Wall Access Covers
8300SH
Square 8 3/4 x8 3/4 " scoriated nickel bronze hinged secured cover and frame.
WADE
OPTIONS
Cat. No. Wt. Lbs. Suffix Description
8300SH8
179 ......... Security Screws
7-14
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Wall Access Covers
8480C
Round smooth nickel bronze secured access cover with frame.
WADE
OPTIONS
Cat. No. B C D Wt. Lbs. Suffix Description
8480C6 8480C7 8480C10
6 7 1/ 4 10
5 1/ 2 6 3/ 4 9 3/ 4
4 1/ 2 5 3/ 4 9
3 4 7
179 ......... Security Screws
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-15
Wall Access Covers
8480R
Round stainless steel access cover with 1/4 -20x3 1/2 center screw.
WADE
Cat. No.
Plug Size
Wt. Lbs.
1 3
8480R6 8480R8
6 8
1 1/2 to 3 1/2 4, 5 and 6
/2 /4
7-16
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Wall Access Covers
8480S
Square nickel bronze frame with secured smooth stainless steel access cover.
WADE
OPTIONS
Cat. No. Wt. Lbs. Suffix Description
8480S
2.5
179 ......... Security Screws
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-17
Access Covers
8480X
Round smooth finish nickel bronze dished access cover with 1/4 -20x3 1/2" long center screw.
WADE
Cat. No.
Wt. Lbs.
8480X6
7-18
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Cleanout Ferrule w/ Plug
8550 (B orE)
Cast Iron cleanout ferrule with spigot outlet and threaded brass raised head, or countersunk plug drilled and tapped for 1/4 20 screw.
WADE
PLUG TYPE
Cat. No. Pipe Size A Plug Size Wt. Lbs. Suffix Description
8552 8553 8554 8555 8556
2 3 4 5 6
2 3/ 4 3 3 1/ 4 4 1/ 2 4 1/ 2
1 1/ 2 2 1/ 2 3 1/ 2 4 5
1.5 2.5 4 6 9
B ............. Raised Head Brass Plug E ............. Countersunk Brass Plug
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-19
Cleanout Tee w/ Plug
8560 (B orE)
Cast Iron cleanout tee with spigot inlet/outlet and threaded brass raised head, or countersunk plug drilled and tapped for 1 /4 -20 screw.
WADE
PLUG TYPE
Cat. No. Pipe Size B C Plug D E Wt. Lbs. Suffix Description
8562 8563 8564 8565 8566*
2 3 4 5 6
6 3/8 7 3/ 4 8 7/8 11 1/2 12 1/2
2 3 4 5 6
2 2 3/4 3 4 1/2 5
3 3/16 3 7/8 4 7/16 5 3/4 6 1/4
2.7 4.8 9.4 14.7 18.4
B ....... Raised Head Brass Plug E ....... Countersunk Brass Plug
* Type E Plug Only
7-20
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts
Cleanout Plugs
8590 (B orE)
Threaded brass raised head, or countersunk plug drilled and tapped for 1/4 -20 screw.
WADE
PLUG TYPE
Cat. No. Plug Size Wt. Lbs. Suffix Description
8591 1/2 8592 8593 8593 1/2 8594 8595 8596
1 1/ 2 2 3 3 1/ 2 4 5 6
.25 .25 .50 .50 .75 1.00 2.00
B ....... Raised Head Brass Plug (Not Available 6") E ....... Countersunk Brass Plug
5-15-2000 Cleanouts
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
7-21
WADE
7-22
Tyler Pipe/Wade Division P.O. Box 2027 Tyler, TX 75710-2027 (903) 882-5511 FAX (888) 879-9233
5-15-2000 Cleanouts