Minimize use of arti cial heating system
unit : % range value: 0 - 100 %
Minimize use of arti cial lighting
unit : % range value: 0 - 100 %
Use of air conditioning
unit : BTU range value: 0 - 100,000 BTU
Maximizing natural daylight
unit : frenquency of arti cial light usage (Range value : 1-100%)
Fresh air supply
unit : % (Range value : 1-100%)
Interior horizontal air movement
unit : km/h range value : 1 - 2km/h
Location of air conditioning Number of operable panels
unit : # range value: 0 - 8542
Size of air ducts
unit (radius) : cm range value: 0 - 50 cm
Maximize energy e ciency
unit: BTUs (energy use) / m / Heating Degree Day (HDD) * 100 (Range value : 1-100%)
2
Maximizing natural ventilation
unit : frenquency of arti cial cooling/ air mechanism usage (Range value : 1-100%)
Interior vertical air movement
unit : km/h range value : 1 - 2km/h
Rotation of the triangular voids
unit : degree range value: 0 - 180 degree
Maximizing the city view
unit : % range value: 0 - 100 %
Increase transparency of facade
unit : % range value: 0 - 100 %
Improving quality of workspace
Number of social spaces
unit : # range value : 0-500
Height of the panels
unit : m range value : 1- 180 m (Height of tower 42)
Size of the core
unit : m
Increase building value
unit :pound per m
2 2 2
Maximum ratio of net rentable to gross oor area
unit : m : m range value: 0-1
2 2
range value : 1-100 % of total gross oor area
Number of tinted glazing
unit : # range value: 0 - 8542
2 2 o o
range value : 1pound/m - $2000 pound/m
Area of the rectangular bays (o ce spaces)
unit :m 2 range value : 1-1000 m
2
Area of the triangular voids
unit :m 2 range value : 1-50 m
2
Radius of the oor plan
(unit : m) range value : 0- max. bldg footprint
Number of garden space
unit : # range value: 0 - 6
Number of the triangular voids
unit : # range value: 0 - 6 r
Volume of atria
unit :m 3 range value : 1-50 m
3
Maximize public space
Ratio of Site to Ground Floor Area unit : sq. m : sq. m range value : 0-1
Shape of oor plans
?
Height of the building
unit : m range value : 1- 180 m (Height of tower 42)
radii of the building contour
unit : m range value : 1-100 m
h h
Pedestrian tra c ow
unit :% of site occupancy (value range: 1% - 100%)
Number of atria
unit : # range value: 0 - 6
Number of rebreak oors
unit : # range value: 0 - 6
Temperature control
unit : Celsius range value: 0 - 24 Celsius
Mitigation of Downdrought
unit : km/h range value : 0-100 %
Integration of form and function
Building geometry Structural material Weight of structure
unit : ton range value : 1 - 8540 tons
Structural e ciency
unit (Structural E ciency Rating) : Maximum Design Load Applied to Structure/ Weight of Structure range value : greater the better
Building surface area
unit :m 2 range value: 1 - 100,000 m
2
Number of cores
unit : # range value : 1- 4
Number of columns
unit : # range value : 1- 30
Location of columns
unit (distance from the edge) : m range value : 1- 60 m
External structure for wind load
unit : # range value: 1 - 100 %
Size of columns
unit (radius) : m range value : 1- 2m
Size of panels
unit (area) : m 2 range value : 1- 3m
2
Cost of fabrication
unit : $ range value: 0 - max. client budget
Structural regularity
unit : % range value: 1 - 100 %
Construction method
Prefabrication vs. on site
facade module geometry
4
Number of panels
unit : # range value: 0 - 8542
Angle of the panel
2
unit : degree range value: 0 - 90 degree
Speed of construction
unit : Days range value: 0 - 1 years
degree of facade band
Norman Fosters Swiss Re HQ Design Process Work ow
(CBIP Precedent Study)