Architectural Design Metrics

The document outlines various design parameters for a high-rise building with metrics for evaluating options. Key parameters include: minimizing artificial heating/lighting and maximizing natural daylight/ventilation; metrics for air conditioning usage, fresh air supply, and air movement; metrics for energy efficiency and maximizing views/transparency; and metrics for structural elements like number of floors/cores, weight, and efficiency. The document seeks to optimize the building design across these various environmental, functional, and structural factors.

Uploaded by

Hee-Yun Kim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views1 page

Architectural Design Metrics

The document outlines various design parameters for a high-rise building with metrics for evaluating options. Key parameters include: minimizing artificial heating/lighting and maximizing natural daylight/ventilation; metrics for air conditioning usage, fresh air supply, and air movement; metrics for energy efficiency and maximizing views/transparency; and metrics for structural elements like number of floors/cores, weight, and efficiency. The document seeks to optimize the building design across these various environmental, functional, and structural factors.

Uploaded by

Hee-Yun Kim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Minimize use of arti cial heating system

unit : % range value: 0 - 100 %

Minimize use of arti cial lighting


unit : % range value: 0 - 100 %

Use of air conditioning


unit : BTU range value: 0 - 100,000 BTU

Maximizing natural daylight


unit : frenquency of arti cial light usage (Range value : 1-100%)

Fresh air supply


unit : % (Range value : 1-100%)

Interior horizontal air movement


unit : km/h range value : 1 - 2km/h

Location of air conditioning Number of operable panels


unit : # range value: 0 - 8542

Size of air ducts


unit (radius) : cm range value: 0 - 50 cm

Maximize energy e ciency


unit: BTUs (energy use) / m / Heating Degree Day (HDD) * 100 (Range value : 1-100%)
2

Maximizing natural ventilation


unit : frenquency of arti cial cooling/ air mechanism usage (Range value : 1-100%)

Interior vertical air movement


unit : km/h range value : 1 - 2km/h

Rotation of the triangular voids


unit : degree range value: 0 - 180 degree

Maximizing the city view


unit : % range value: 0 - 100 %

Increase transparency of facade


unit : % range value: 0 - 100 %

Improving quality of workspace

Number of social spaces


unit : # range value : 0-500

Height of the panels


unit : m range value : 1- 180 m (Height of tower 42)

Size of the core


unit : m

Increase building value


unit :pound per m
2 2 2

Maximum ratio of net rentable to gross oor area


unit : m : m range value: 0-1
2 2

range value : 1-100 % of total gross oor area

Number of tinted glazing


unit : # range value: 0 - 8542

2 2 o o

range value : 1pound/m - $2000 pound/m

Area of the rectangular bays (o ce spaces)


unit :m 2 range value : 1-1000 m
2

Area of the triangular voids


unit :m 2 range value : 1-50 m
2

Radius of the oor plan


(unit : m) range value : 0- max. bldg footprint

Number of garden space


unit : # range value: 0 - 6

Number of the triangular voids


unit : # range value: 0 - 6 r

Volume of atria
unit :m 3 range value : 1-50 m
3

Maximize public space


Ratio of Site to Ground Floor Area unit : sq. m : sq. m range value : 0-1

Shape of oor plans

?
Height of the building
unit : m range value : 1- 180 m (Height of tower 42)

radii of the building contour


unit : m range value : 1-100 m

h h

Pedestrian tra c ow
unit :% of site occupancy (value range: 1% - 100%)

Number of atria
unit : # range value: 0 - 6

Number of rebreak oors


unit : # range value: 0 - 6

Temperature control
unit : Celsius range value: 0 - 24 Celsius

Mitigation of Downdrought
unit : km/h range value : 0-100 %

Integration of form and function

Building geometry Structural material Weight of structure


unit : ton range value : 1 - 8540 tons

Structural e ciency
unit (Structural E ciency Rating) : Maximum Design Load Applied to Structure/ Weight of Structure range value : greater the better

Building surface area


unit :m 2 range value: 1 - 100,000 m
2

Number of cores
unit : # range value : 1- 4

Number of columns
unit : # range value : 1- 30

Location of columns
unit (distance from the edge) : m range value : 1- 60 m

External structure for wind load


unit : # range value: 1 - 100 %

Size of columns
unit (radius) : m range value : 1- 2m

Size of panels
unit (area) : m 2 range value : 1- 3m
2

Cost of fabrication
unit : $ range value: 0 - max. client budget

Structural regularity
unit : % range value: 1 - 100 %

Construction method
Prefabrication vs. on site

facade module geometry


4

Number of panels
unit : # range value: 0 - 8542

Angle of the panel


2

unit : degree range value: 0 - 90 degree

Speed of construction
unit : Days range value: 0 - 1 years

degree of facade band

Norman Fosters Swiss Re HQ Design Process Work ow


(CBIP Precedent Study)

unit : degree range value: 0 - 90 degree