PanelView Component Specifications
PanelView Component Specifications
Topic Environmental Specifications General Specifications Certifications Technical Specifications Dimensions Accessories Software Cables Additional Resources
Page 2 3 3 4 6 8 9 10 11
Environmental Specifications
Table 1 - Environmental Specifications - PanelView Component Terminals
Attribute Temperature, operating 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): 050 C (32122 F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -2570 C (-13158 F) 50 C (122 F) C200/C300: 16 BTU/hr C400: 24 BTU/hr C600: 32 BTU/hr C1000: 58 BTU/hr IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 595% noncondensing IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10500 Hz IEC 60068-2-27 (Test Ea, Unpackaged Shock): 15 g @ 11 ms IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g CISPR 11: Group 1, Class A IEC 61000-4-2: 4 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz 3V/m with 1 kHz sine-wave 80% AM from 14002000 MHz 1V/m with 1 kHz sine-wave 80% AM from 20002700 MHz IEC 61000-4-4: 2 kV @ 5 kHz on power ports 1 kV @ 5 kHz on communication ports IEC 61000-4-5: 500V line-line (DM) and 1 kV line-earth (CM) on DC power ports 1 kV line-earth (CM) on communication ports IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
Temperature, nonoperating
Relative humidity Vibration Shock, operating Shock, nonoperating Emissions ESD immunity
Radiated RF immunity
EFT/B immunity
Conducted RF immunity
General Specifications
Table 2 - General Specifications
Attribute Isolation voltage 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C For 2711C-T4T only 30V (continuous), Basic Insulation Type Tested @ 500V for 60 s, line to Ethernet No isolation between all ports to line, except Ethernet port Duration indicates that the product was qualification or type tested to the specified level (one time tested on a representative sample) Single-Wire Gauge: 0.332.08 mm2 (22...14 AWG) Dual-wire Gauge: 0.331.31 mm2 (2216 AWG) Earth wire: 2.083.31 mm2 (1412 AWG) Solid or stranded copper wire rated @ 90 C (194 F ), or greater 1 on power ports 1 on communication ports Meets NEMA/UL Type 4X (indoor) 12, 13, and IEC IP54, IP65 (when marked) C600 Series B only: NEMA/UL Type 12, 13, and IEC IP54 T3C for 2711C-T4T only
Wire size
Wire type Wiring category(1) Enclosure type ratings North American Temp Code
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Certifications
Table 3 - Certifications - PanelView Component Terminals
Certification(1) c-UL-us CE 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E113724. UL Listed for Class 1, Division 2, Group A, B, C, D, Hazardous Locations, certified for U.S. and Canada. See UL File E10314. European Union2004/108/EC EMC Directive, compliant with: EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3
C-Tick KCC
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Technical Specifications
The tables in this section provide technical specifications for the PanelView Component terminals.
Real-time clock Battery Programming port Communication ports Memory card Software
No battery backup 5 year min at 25 C (77 F) USB device port RS-232 (DH-485), RS-232 (DF1), RS485 Multi-vendor communication available for Modbus, Modbus/TCP, Siemens MPI devices USB flash drive DesignStation sofware, version 2.0 or later Web-enabled software resident in terminal accessed through web browser Browser support: Firefox 3.0, Internet Explorer 7 or 8 Emulator available MicroLogix, SLC, and Micro800 controllers 1830V DC (24V DC nom) 5 W max (0.21 A at 24V DC) 0.19 g (0.40 lb) 80 x 116 x 54 mm 3.15 x 4.54 x 2.13 in. 65 x 100 mm 2.56 x 3.94 in. 0.30 kg (0.65 lb) 119 x 139 x 55 mm 4.69 x 5.47 x 2.15 in. 100 x 120 mm 3.94 x 4.72 in. 0.20 kg (0.43 lb) 80 x 116 x 57 mm 3.15 x 4.54 x 2.23 in. 65 x 100 mm 2.56 x 3.94 in. 0.30 kg (0.65 lb) 119 x 139 x 55 mm 4.69 x 5.47 x 2.15 in. 100 x 120 mm 3.94 x 4.72 in.
Preferred controller Input voltage, DC Power consumption, DC Weight, approx Dimensions (HxWxD), approx Cutout dimensions (HxWxD), approx
Table 5 - Technical Specifications - PanelView Component C400, C600, and C1000 Terminals
Attribute Display type Display size Display area (WxH) Resolution Backlight C400 2711C-T4T Color transmissive TFT active matrix LCD 4.3 in. 95 x 53.86 mm (3.74 x 2.12 in.) 480 x 272 40,000 hours life, min; not replaceable White LED backlight Operator input Real-time clock Battery life Programming port Communication ports Memory card Software Analog touch Actuation rating: 1,000,000 presses Battery backup 5 year min at 25 C (77 F) USB device port or Ethernet port RS-232 (DH-485), RS-232 (DF1), RS485, Ethernet Multi-vendor communication available for Modbus, Modbus/TCP, Siemens MPI devices USB flash drive USB flash drive Secure Digital (SD) card: Cat. no. 2711C-RCSD, USB to SD adapter with SD card White LED backlight C600 2711C-T6T Color transmissive TFT active matrix LCD 5.7 in. 115 x 86 mm (4.53 x 3.39 in.) 320 x 240 50,000 hours life, min; not replaceable CCFL C600 2711C-T6M Monochrome transmissive FSTN passive matrix C1000 2711C-T10C Color transmissive TFT active matrix LCD 10.4 in. 211 x 158 mm (8.31 x 6.22 in.) 640 x 480
DesignStation sofware, version 2.0 or later Web-enabled software resident in terminal accessed through web browser Browser support: Firefox 3.0, Internet Explorer 7 or 8 Emulator available MicroLogix, SLC, and Micro800 controllers 1830V DC (24V DC nom) 3.5 W max (0.14 A at 24V DC) 0.35 g (0.76 lb) 113 x 138x 43 mm 4.45 x 5.43 x 1.69 in. 99 x 119 mm 3.9 x 4.69 in. 1830V DC (24V DC nom) 10 W max (0.42 A at 24V DC) 0.68 g (1.48 lb) 154 x 209 x 57 mm 6.0 x 8.23 x 2.25 in. 136 x 190 mm 5.35 x 7.48 in. 18 W max (0.75 A at 24V DC) 1.57 kg (3.41 lb) 250 x 308 x 54 mm 9.84 x 12.13 x 2.13 in. 232 x 290 mm 9.13 x 11.42 in.
Preferred controller Input voltage, DC Power consumption, DC Weight, approx Dimensions (HxWxD), approx Cutout dimensions (HxWxD), approx
Dimensions
Dimensions are provided for the PanelView Component terminals.
Figure 1 - PanelView Component C200 and C300 Terminals
c d
a
F1 1 F6 6 F2 2 F7 7 F3 3 F8 8 F4 4 F9 9 F5 5 F10 0
Figure 2 - PanelView Component C200 Function Key and C300 Touch Terminals
c d
a
F1 F2 F3 F4
139 mm (5.47 in.) 55 mm (2.15 in.) 116 mm (4.57 in.) 54 mm (2.13 in.) 57 mm (2.23 in.)
Accessories
Tables 811 list the accessories for the PanelView Component terminals.
Table 8 - SD Card
Cat. No. 2711C-RCSD Description USB to SD adapter with SD card
2711C-RG2F
Software
The PanelView Component stands apart from other HMI devices with its on-terminal programming software. Eliminating the need to install software on a personal computer reduces both start-up and servicing time. Just connect your computer to the PanelView Component through a USB cable or Ethernet, then launch the software through your web browser. Both Microsoft Internet Explorer and Mozilla Firefox are supported. A dashboard provides a single point of entry for accessing all terminal and design operations. Take advantage of these features while connected to the terminal: Launch the design environment where navigation tabs guide you through application development. View the results of your design efforts directly on the terminal without having to download the application first. Modify terminal display and communication settings, view system information, and enable login security. Transfer files between PanelView Component storage and a USB flash drive, SD card, or computer; and delete files from terminal storage. Change the start-up application or language the terminal uses for configuration screens and diagnostic messages. For programming without a PanelView Component, you can create an application using the free DesignStation software or an emulator. The emulator and browser must be on the same computer.
Table 12 - Supported Browsers and Platforms
Operating System Windows 7 Windows Vista Windows XP SP2 Browser Internet Explorer 7 and 8, Firefox 3.0 Internet Explorer 7 and 8 Platform Supported Terminal and emulator DesignStation 2.0 or later
Cables
Use these cables for connecting PanelView Component terminals.
Table 13 - Cables for PanelView Component Terminals
Cat. No. 2711C-CBL-UU02 2711P-CBL-EX04 2711C-RCSD 1747-CP3 1761-CBL-PM02 2711C-CBL-AB03 Description USB-A host to USB-B device cable, 2 m (6.5 ft) Ethernet crossover CAT5 cable, 4.3 m (14 ft) USB to SD adapter with SD card Serial 9-pin D-shell to 9-pin D-shell null modem cable, 3 m (10 ft) Serial 9-pin D-shell to 8-pin mini DIN cable, 2 m (6.5 ft) RS-485 5-pin to RJ45 cable For Use With C200, C300, C400, C600, C1000 C400, C600, C100 C200, C300, C400, C600, C1000 C200, C300, C400, C600, C1000 C200, C300, C400, C600, C1000 C200, C300, C600, C1000
(1) RS-485 is nonisolated and is recommended for connecting to only one device with an isolated port.
10
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Table 15 - Additional Resources
Resource PanelView Component Installation Instructions, publication 2711C-IN001 PanelView Component User Manual, publication 2711C-UM001 PanelView Component Quick Start, publication 2711C-QS001 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.ab.com Description Provides instructions for installing a PanelView Component terminal. Provides information on how to configure and operate the PanelView Component terminal, including troubleshooting information. Provides instructions on setting up a sample application on a PanelView Component terminal. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://rockwellautomation.com/literature. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative
11
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, MicroLogix, SLC, PowerFlex, Micro800, PanelView, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.