JOB REF:
D2010
PROJECT:
Company logo
REVISION:
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05
6.5 METHOD 2- ANALYTICAL PROCEDURE
Applicable since the building satisfies the two conditions set forth in Sec. 6.5.1:
(ASCE 7-05, 6.2)
1. The building is regular in shape
2. The building does not have response characteristics making it subject to across wind loading, vortex shedding, instability due to galloping or flutter; or
does not have a site location for which channeling effects or buffeting in the wake of upwind obstructions warrant special consideration.
roof
6.5.12. Design Wind Loads on Enclosed and Partially Enclosed Buildings. (all Heights)
= 99
= 33
Height above local ground level
number of stories
= (0.613 v) Kz Kzt Kd I
Velocity pressure where, 0.613=1/5 Air density
= 45
Basic wind speed (3 sec gust)
m/sec
leeward
No.
qz
windward
(ASCE 7-05, 6.5.10)
= 100.6621 mph
local Gr. Level
Terrain category:
Exposure B
Exposure C
ASCE 7-05, Table(6-4)
Structure Type
Kd
= 0.95
Exposure D
Kd
Directionality factor
Occupancy category of buildings and other structures for wind loads
ASCE 7-05, Table (1-1)
Nature of Occupancy
166022899.xls.ms_office
(ASCE 7-05, 6.5.4.4)
JOB REF:
D2010
PROJECT:
Company logo
REVISION:
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
*Cogeneration power plants that do not supply power on the national grid shall be designated Occupancy Category II.
Occupancy Category:
III
Region
I
= 1.15
(ASCE 7-05, 6.5.5, Table [6-4])
Importance factor
ASCE 7-05, Table (6-2)
Exposure
a
b0.45
zmin*
365.76
a114.0
7.0
b^
0.84
a^
117.0
0.30
97.54
113
9.14
9.5
274.32
119.5
1.00
116.5
0.65
0.20
152.40
115
4.57
11.5
213.36
1111.5
1.07
119.0
0.80
0.15
198.12
118
2.13
zg
*zmin = minimum height used to ensure that the equivalent height z is greater of 0.6h or z min.
For buildings with h 5 zmin, z shall be taken as zmin
a
zg
= 9.5
= 274.32
Kz
= 2.01(z/zg)2/a
= 2.01(4.572/zg)2/a
Kz min
m
(ASCE 7-05, 6.5.6.6, Table [6-3])
Velocity exposure (see the following tables)
(metric units)
Local ground
H/2
Lh
Hill shape
H
Lh
= 0
= 13000
H/Lh
= 0.00
= 500
K1/(H/Lh) = 1.45
166022899.xls.ms_office
Direction
m
Height of Hill
Distance upwind of crest to where the difference in ground elevation is half the height of hill
Distance from the crest to the building
JOB REF:
D2010
PROJECT:
Company logo
K1
Lh
= 0.00
= 13000
m
K2
= 1.50
= 0.97
1 - x/mLh
g
K3
= 3.00
= 0.98
e-gz/Lh
Kzt
= 1.00
[1+K1K2K3]2
= 0.85
Gust effect factor
REVISION:
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
(ASCE 7-05, 6.5.7, Figure [6-4])
Topographic factor
Enclosure classification
GCpi
Cp
Cp
= 0.55
= 0.80
Internal Pressure Coefficient, GCpi
(ASCE 7-05, 6.5.9, Figure [6-5])
Windward wall
(ASCE 7-05, 6.11.2, Figure [6-6])
= -0.50
= -0.70
Leeward wall
(ASCE 7-05, 6.11.2, Figure [6-6])
Cp
Side wall
(ASCE 7-05, 6.11.2, Figure [6-6])
Cp
= variable as shown
Roof
(ASCE 7-05, 6.11.2, Figure [6-6])
-0.70
0.80
Plan
-0.90
-0.50
-0.30
-0.50
0.80
Elevation
-0.50
-0.70
= qGCp-qi(GCpi)
= qz
qi
= qh
= qh
166022899.xls.ms_office
(ASCE 7-05, 6.5.12)
For windward walls, evaluated at height z from the ground
For leeward walls, side walls, and roofs, evaluated at height h
For windward walls, side walls, leeward walls, and roofs of enclosed buildings
JOB REF:
D2010
PROJECT:
Company logo
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05
Output velocity pressures
Kd
z
v
166022899.xls.ms_office
REVISION:
Kzt
45
0.95
1.15
0.848884 1151.212
Kz
qz
45
0.95
1.15
0.848884 1151.212
45
0.95
1.15
0.898876 1219.009
45
0.95
1.15
0.978976 1327.635
12
45
0.95
1.15
1.040099 1410.528
15
45
0.95
1.15
1.090126 1478.372
18
45
0.95
1.15
1.132783
21
45
0.95
1.15
1.170148 1586.893
24
45
0.95
1.15
1.203509 1632.136
27
45
0.95
1.15
1.233725 1673.113
30
45
0.95
1.15
1.261396
33
45
0.95
1.15
1.286962 1745.311
36
45
0.95
1.15
1.310754 1777.576
39
45
0.95
1.15
1.333029 1807.784
42
45
0.95
1.15
1.35399
1836.21
45
45
0.95
1.15
1.3738
1863.075
48
45
0.95
1.15
1.392593 1888.562
51
45
0.95
1.15
1.410481
54
45
0.95
1.15
1.427556 1935.977
57
45
0.95
1.15
1.443898 1958.139
60
45
0.95
1.15
1.459575 1979.399
63
45
0.95
1.15
1.474644 1999.835
66
45
0.95
1.15
1.489157 2019.517
69
45
0.95
1.15
1.503159 2038.505
72
45
0.95
1.15
1.516687 2056.852
75
45
0.95
1.15
1.529778 2074.605
78
45
0.95
1.15
1.542462 2091.806
81
45
0.95
1.15
1.554766 2108.492
84
45
0.95
1.15
1.566715 2124.697
87
45
0.95
1.15
1.578333 2140.452
90
45
0.95
1.15
1.589638 2155.783
93
45
0.95
1.15
1.600649 2170.716
96
45
0.95
1.15
1.611384 2185.274
99
45
0.95
1.15
1.621856 2199.477
1536.22
1710.64
1912.82
ASCE7-05
JOB REF:
D2010
PROJECT:
Company logo
REVISION:
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
ASCE7-05
DESIGN CODE
WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05
Output combined pressures
External pressure
Location
qz
Cp
Internal pressure
Combined pressure
qzGCp
qi
GCpi
qiGCpi
qzGCp+qiGCpi
qzGCp-qiGCpi
Leeward
All
2199.48
-0.5
0.85
-934.78
2199.48
0.55
1209.71
274.93
-2144.49
Side walls
All
2199.48
-0.7
0.85
-1308.69
2199.48
0.55
1209.71
-98.98
-2518.40
Roof
99
2199.48
-0.9
0.85
-1682.60
2199.48
0.55
1209.71
-472.89
-2892.31
1151.21
0.8
0.85
782.82
2199.48
0.55
1209.71
1992.54
-426.89
1151.21
0.8
0.85
782.82
2199.48
0.55
1209.71
1992.54
-426.89
1219.01
0.8
0.85
828.93
2199.48
0.55
1209.71
2038.64
-380.79
1327.64
0.8
0.85
902.79
2199.48
0.55
1209.71
2112.50
-306.92
12
1410.53
0.8
0.85
959.16
2199.48
0.55
1209.71
2168.87
-250.55
15
1478.37
0.8
0.85
1005.29
2199.48
0.55
1209.71
2215.01
-204.42
18
1536.22
0.8
0.85
1044.63
2199.48
0.55
1209.71
2254.34
-165.08
21
1586.89
0.8
0.85
1079.09
2199.48
0.55
1209.71
2288.80
-130.63
24
1632.14
0.8
0.85
1109.85
2199.48
0.55
1209.71
2319.56
-99.86
27
1673.11
0.8
0.85
1137.72
2199.48
0.55
1209.71
2347.43
-72.00
30
1710.64
0.8
0.85
1163.23
2199.48
0.55
1209.71
2372.95
-46.48
33
1745.31
0.8
0.85
1186.81
2199.48
0.55
1209.71
2396.52
-22.90
36
1777.58
0.8
0.85
1208.75
2199.48
0.55
1209.71
2418.46
-0.96
39
1807.78
0.8
0.85
1229.29
2199.48
0.55
1209.71
2439.01
19.58
42
1836.21
0.8
0.85
1248.62
2199.48
0.55
1209.71
2458.33
38.91
45
1863.08
0.8
0.85
1266.89
2199.48
0.55
1209.71
2476.60
57.18
48
1888.56
0.8
0.85
1284.22
2199.48
0.55
1209.71
2493.93
74.51
51
1912.82
0.8
0.85
1300.72
2199.48
0.55
1209.71
2510.43
91.01
54
1935.98
0.8
0.85
1316.46
2199.48
0.55
1209.71
2526.18
106.75
57
1958.14
0.8
0.85
1331.53
2199.48
0.55
1209.71
2541.25
121.82
60
1979.40
0.8
0.85
1345.99
2199.48
0.55
1209.71
2555.70
136.28
63
1999.84
0.8
0.85
1359.89
2199.48
0.55
1209.71
2569.60
150.18
66
2019.52
0.8
0.85
1373.27
2199.48
0.55
1209.71
2582.98
163.56
69
2038.50
0.8
0.85
1386.18
2199.48
0.55
1209.71
2595.90
176.47
72
2056.85
0.8
0.85
1398.66
2199.48
0.55
1209.71
2608.37
188.95
75
2074.60
0.8
0.85
1410.73
2199.48
0.55
1209.71
2620.44
201.02
78
2091.81
0.8
0.85
1422.43
2199.48
0.55
1209.71
2632.14
212.72
81
2108.49
0.8
0.85
1433.77
2199.48
0.55
1209.71
2643.49
224.06
84
2124.70
0.8
0.85
1444.79
2199.48
0.55
1209.71
2654.51
235.08
87
2140.45
0.8
0.85
1455.51
2199.48
0.55
1209.71
2665.22
245.80
90
2155.78
0.8
0.85
1465.93
2199.48
0.55
1209.71
2675.64
256.22
93
2170.72
0.8
0.85
1476.09
2199.48
0.55
1209.71
2685.80
266.38
96
2185.27
0.8
0.85
1485.99
2199.48
0.55
1209.71
2695.70
276.27
99
2199.48
0.8
0.85
1495.64
2199.48
0.55
1209.71
2705.36
Windward
166022899.xls.ms_office
285.93
JOB REF:
D2010
PROJECT:
Company logo
REVISION:
PART OF STRUCTURE:
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05
Design wind loads
Windward face
Leeward face
Tributary
height
Building
width
Design wind pressure
Design wind force (kN)
Design wind pressure
Design wind force (kN)
Combined
design wind
force (kN)
1.4
1992.54
8.37
274.93
1.15
7.21
1.4
1992.54
8.37
274.93
1.15
7.21
1.4
2038.64
8.56
274.93
1.15
7.41
12
1.4
2112.50
8.87
274.93
1.15
7.72
15
1.4
2168.87
9.11
274.93
1.15
7.95
18
1.4
2215.01
9.30
274.93
1.15
8.15
21
1.4
2254.34
9.47
274.93
1.15
8.31
24
1.4
2288.80
9.61
274.93
1.15
8.46
27
1.4
2319.56
9.74
274.93
1.15
8.59
30
1.4
2347.43
9.86
274.93
1.15
8.70
33
1.4
2372.95
9.97
274.93
1.15
8.81
36
1.4
2396.52
10.07
274.93
1.15
8.91
39
1.4
2418.46
10.16
274.93
1.15
9.00
42
1.4
2439.01
10.24
274.93
1.15
9.09
45
1.4
2458.33
10.33
274.93
1.15
9.17
48
1.4
2476.60
10.40
274.93
1.15
9.25
51
1.4
2493.93
10.47
274.93
1.15
9.32
54
1.4
2510.43
10.54
274.93
1.15
9.39
57
1.4
2526.18
10.61
274.93
1.15
9.46
60
1.4
2541.25
10.67
274.93
1.15
9.52
63
1.4
2555.70
10.73
274.93
1.15
9.58
66
1.4
2569.60
10.79
274.93
1.15
9.64
69
1.4
2582.98
10.85
274.93
1.15
9.69
72
1.4
2595.90
10.90
274.93
1.15
9.75
75
1.4
2608.37
10.96
274.93
1.15
9.80
78
1.4
2620.44
11.01
274.93
1.15
9.85
81
1.4
2632.14
11.05
274.93
1.15
9.90
84
1.4
2643.49
11.10
274.93
1.15
9.95
87
1.4
2654.51
11.15
274.93
1.15
9.99
90
1.4
2665.22
11.19
274.93
1.15
10.04
93
1.4
2675.64
11.24
274.93
1.15
10.08
96
1.4
2685.80
11.28
274.93
1.15
10.13
99
1.4
2695.70
11.32
274.93
1.15
166022899.xls.ms_office
10.17
last cell in output velocity pressure to be deleted
Cp
not calculated as per the figures
Gust factor not calculated exactly