Catalog ASTROL PVC Pipe Fittings
Catalog ASTROL PVC Pipe Fittings
Corrosion Resistant
Fire safety
PRODUCT CATALOGUE
Safe for drinking water Cost effective
IS 15778
CM/L-3673470
st to introduce
in india
ABOUT US
Astral Poly Technik Ltd is very proud to introduce CHLORINATED POLY VINYL CHLORIDE [CPVC] for the first time into this part of the globe, under license from Lubrizol, [formerly Noveon, USA] under brand name Astral FlowGuard CPVC. It is also manufacturing Industrial Piping System under brand name Astral Corzan CPVC. It has a techno commercial joint venture with Specialty Process LLC, USA, the world leaders of manufacturing FlowGuard CPVC Pipes and Fittings in USA since last 32 Years. Astral FlowGuard pipes and fittings, manufactured by Astral Poly Technik Ltd, are made from the specialty plastic, chemically known as Chlorinated Poly Vinyl Chloride [CPVC]. This CPVC compound meets cell class 23447 B as defined by ASTM D1784 and have a design stress of 2000 PSI and a maximum service temperature upto 93C. Pipes are produced in copper tube size (CTS) from 15 mm (") to 50 mm (2") with two different standard dimensional ratios - SDR-11 and SDR-13.5. The fittings are produced as per SDR 11. All Astral CPVC SDR 11 and SDR 13.5 pipes are made from identical CPVC compound material having same physical properties. The CPVC fittings are manufactured from compound material which meets all the requirement as per ASTM standard. CPVC pipes of Copper Tube Size (CTS) dimensions can also be applied to CPVC (IPS) dimensions by using IPS x CTS fittings. The CPVC pipes from 15 mm (") to 50 mm (2") are also produced as per IS 15778 standard in both class that is Class 1 (SDR 11) and Class 2 (SDR 13.5). Apart from having the same physical properties, SDR 11 and SDR 13.5 which are having different wall thickness and therefore, at any given temperature, they have different pressure ratings. For e.g. Astral also produces FlowGuard pipes in iron pipe size (IPS), available sizes are 65 mm (2") to 100 mm (4") in SCH 40 and 65mm (2") to 300 mm (12") in SCH 80 which meets the requirements of ASTM F 441. The pressure ratings varies with schedule pipe size and temperature. Astral is the only pipe manufacturing company in India having most prestigious quality certification from National Sanitation Foundations (NSF) and Bureau of Indian Standards(BIS). Astral products are regularly tested at CIPET, CBRI - Roorkee and Shriram Institute and also received state approvals from BMC, CPWD, PWD, DGMAP etc. for domestic and public sanitation.
MARKETING NETWORK :
Astral has marketing network of more than 300 distributors and 9,500 dealers spread all over India with branch offices at Mumbai, Delhi, Bengaluru, Chennai and Hyderabad apart from that Astral has it's own warehouses at Bengaluru, Coimbatore, Vijaywada, Goa and Delhi to deliver the material as quick as possible. More than 150 techno marketing professionals and administrative personals are on the board to coordinate with architects, plumbing contractors and plumbers to utilize the best plumbing techniques and to get the best from the product.
FIELDS OF APPLICATIONS :
Hot and Cold water applications in homes, apartments, hotels, resorts, hospitals, high and low rise buildings, corporate and commercial houses, academic institutes etc. for pure and hygienic water supply.
Temperature (C) 23 82 23 82
Pressure Rating (PSI) 400 100 320 80 (Kg/Cm2) 28.10 7.00 22.50 5.60
NSF CERTIFIED
NSF International, a not-for-profit, non-governmental organization, is the world leader in standards development, product certification, education, and risk management for public health and safety (www.nsf.org). For 65 years, NSF has been committed to public health, safety and environmental protection. The NSF Mark is recognized for its value in international trade and is respected by regulatory agencies at the local, state, and national levels. Astral is the first Indian company to obtain certification from NSF for its CPVC products.
WHY
PIPE AND FITTINGS ARE THE BEST CHOICE FOR HOT AND COLD POTABLE WATER DISTRIBUTION ?
Astral FlowGuard CPVC
piping system has winning edge over any other piping systems. Here are few parameters which make Astral FlowGuard hot and cold water plumbing system stands as best in comparison to any other outdated plumbing system
Germany : Deutscher Verein des Gas-und Wasserfaches UK Canada Holland France Turkey
: Water Research Council (WRC) : Canadian Standards Association (CSA) : Keurings instituut voor Water leiding artikelen (KIWA) : Center Scientifique et technique du batiment (CSTB) : Turkish Standard Institution (TSE)
NSF APPROVED SOLVENT CEMENT : All Weld-On solvent cements, primers and cleaners meet the requirements for Low VOC (volatile organic compound) emission limits established by the California South Coast Air Quality Management District (SCAQMD), one of the USA's strictest air quality regulatory bodies. Low VOC emissions contribute to cleaner air.
All Weld-On Low VOC solvent cements provide the following benefits :
* High Quality Performance with excellent installation properties. User Friendly. Reduced fumes and odour for the comfort and well being of pipe installers. NSF, UPC and/or CSA Listed.* Meet ASTM Standards for solvent cements used for plastic pipe installation.* Environmentally Responsible. LEED Compliant (Leadership in Energy and Environmental Design).** Refer to individual solvent cement for specific ASTM Standards, NSF, UPC and/or CSA Listings.
** LEED Green Building Rating System For New Construction & Major Renovations Version 2.2 (Indoor Environmental Air Quality: EQ Credit 4.1 Low-Emitting Materials - Adhesives & Sealants)
Astral recommends NSF approved IPS weld on solvent cement for reliable and leak proof joints between CPVC pipes and fittings.
CBRI
5.0 Conclusions & Recommendations
Based on generated data during experimental work, Astral brand CPVC pipes and fittings have been found suitable for hot and cold water supply in buildings. Astral brand CPVC pipes and fittings meet the requirements of ASTM D 2846 (properties of pipes and fittings) IS: 10500-91 (quality of water) and IS: 10151-82 (overall migration of leachable additives). Works has been carried out on the samples supplied by the party and the reported results are based on thees samples.
11/25
WHY ASTRAL
STATE OF ART MANUFACTURING
CPVC ?
CERTIFICATIONS
NSF and ISI Certifications : Astral the only pipe manufacturing company in India now having most prestigious quality certifications from National sanitation Foundation (NSF) and Bureau of Indian Standards (BIS).
IS 15778
Astral is equipped with state of art manufacturing facilities at both Ahmedabad and Himachal Pradesh plants. High speed and accurate extruders and injection molding machines including innovative manufacturing techniques being used to manufacture the ultra modern, errorless Astral FlowGuard pipes and fittings.
APPROVALS IN INDIA
Bureau of Indian Standards Approval - ISI marked NSF certificate for CPVC pipe & fittings (ASTRAL - The only pipe
manufacturing company in India now having two most prestigious quality certifications from National Sanitation Foundation and Bureau of Indian Standards.) State Approvals of CPVC System - BMC, CPWD, PWD, DGMAP etc. Tested in India regularly by CIPET, CBRI - Roorkee, Shriram Institute Apart from manufacturing and distributing world class FlowGuard CPVC pipes and fittings, Astral takes care of its products by constantly testing and checking CPVC pipes and fittings in their orld class Quality Assurance Laboratory, where various tests are carried out at regular intervals to exceed the quality levels beyond the industry standards.
pw
NSF certification for CPVC pipes and fittings. (check NSF website for listing of Astral's products)
http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=1S170&Standard=014
Live Safer
Astral also takes care of its customers by training plumbers and plumbing contractors throughout the year by updating them about modern plumbing techniques and to do plumbing work more effectively and professionally.
*NSF International is a non-profit nongovernmental organization that provides standards development, product certification, auditing, education and risk management for public health and safety. NSF is a World Health Organization Collaborating Centre for Food and Water Safety and Indoor Environment. Serving companies in over 100 countries
TEST
ASTM D792 ASTM D570 ASTM D785 ASTM D1784
CONDITION
73F / 23C 73F / 23C 73F / 23C 212F/100C 73F / 23C
ENGLISH UNITS
1.55 g/cm3 0.645 cm3 /g +0.03% +0.55% 119 23447-B
SI UNITS
1.55 g/cm3 0.645 cm3 /g +0.03% +0.55%
ASTM D256 ASTM D638 ASTM D638 ASTM D790 ASTM D790 ASTM D695 ASTM D695
73F / 23C 73F / 23C 73F / 23C 73F / 23C 73F / 23C 73F / 23C 73F / 23C
1.5 ft Ibs/in o.n 8000 psi 360,000 psi 15,100 psi 415,000 psi 10,100 psi 196,000 psi
80 J/m o.n. 55 N/mm2 2500 N/mm2 104 N/mm2 2860 N/mm2 70 N/mm2 1350 N/mm2
3.4x10-5 in/in/F 0.95 BTU in/hr/ft2/F 217F 0.21 BTU/IbF 0.26 BTU/IbF
FLAMMABILITY Flammability Rating Flame Spread Smoke Developed Limiting Oxygen Index ELECTRICAL Dielectric Strength Dielectric Constant Power Factor Volume Resistivity
0.062 in/0.157 cm
Thermal Conductivity
0.30 0.25
Fire safety
OTHER CPVC PIPE PLASTIC PIPE
CPVC has a limiting Oxygen Index (LOI) of 60. Thus in air, Astral CPVC pipe does not support combustion. No flaming drips, does not increase the fire load, low flame spread, low smoke generation.
pw
CM/L-3673470
Only those products bearing the NSF Mark are certified
10
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846
pw
Size (mm)
TRANSITION COUPLING
Size (In.)
IPS x CTS 1 IPS x 1 CTS
PartNo.
T 4342 M 4111
Quantity (Case)
10 / 100 50 / ---
TRANSITION BUSHING
(IPS x CTS)
20 x 20 25 x 25
Size (mm)
15 x 15 20 x 20 25 x 25 32 x 32 40 x 40 50 x 50 1 1 1 2
Size (In.)
IPS IPS IPS IPS IPS IPS x CTS x CTS x 1 CTS x 1 CTS x 1 CTS x 2 CTS
PartNo.
M M M M M M 2902 2903 2904 2905 2906 2908
Quantity (Case)
1500 1000 200 150 80 50
COUPLING
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 4120 4340 4100 4105 4106 4200
Quantity (Case)
1200 600 600 300 200 50
REDUCER COUPLING
Size (mm)
20 x 15 25 x 15 25 x 20 32 x 15 32 x 20 32 x 25 40 x 15 40 x 20 40 x 25 40 x 32 50 x 15 50 x 20 50 x 25 50 x 32 50 x40
Size (In.)
1 1 1 1 1 1 1 1 1 2 2 2 2 2 x x x x x x x x x x x x x x x * * 1 * 1 1 * 1 1 1
PartNo.
M 4341 M 4420 M 4134 M 4520 M 4530 M 4540 M 4620 M 4630 M 4640 M 4650 M 4820 M 4830 M 4840 M 4850 M 4860
Quantity (Case)
800 500 400
REDUCER BUSHING
Size (mm)
20 x 15 25 x 15 25 x 20 32 x 15 32 x 20 32 x 25 40 x 15 40 x 20 40 x 25 40 x 32 50 x 15 50 x 20 50 x 25 50 x 32 50 x 40
200 75 75 50 40 30 30
Size (In.)
1 1 1 1 1 1 1 1 1 2 2 2 2 2 x x x x x x x x x x x x x x x 1 1 1 1 1 1
PartNo.
M 2032 M 2102 M 2103 M 2112 M 2113 M 2114 M 2122 M 2123 M 2124 M 2125 M 2202 M 2203 M 2204 M 2205 M 2206
Quantity (Case)
1000 600 600 300 300 300 200 200 200 200 100 150 100 100 100
11
* Reducer fittings are professionally assembled using Flowguard fittings and bushings. Quantity as per order. NOTE : Fabricated reducer fittings are not eligible for return to the manufacturer.
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 TEE
Size (mm)
15 20 25 32 40 50
pw
Part No.
M M M M M M 7120 7340 7100 7105 7106 7200
Size (In.)
1 1 1 2
Quantity (Case)
600 500 300 150 80 40
ELBOW 90
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 5120 N 5340 N 5100 N 5105 N 5106 N 5200 N
Quantity (Case)
1000 800 400 200 120 50
ELBOW 45
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 5123 N 5343 N 5103 N 5153 N 5163 N 5203 N
Quantity (Case)
500 200 250 60 40 15
REDUCER TEE
Size (mm)
15 x 15 x 20 20 x 15 20 x 15 x 20 20 x 15 x 15 25 x 25 x 20 40 x 40 x 25 50 x 50 x 25 32 x 15 32 x 20 32 x 25 50 x 15 25 x 15 40 x 15 40 x 20 40 x 32 50 x 20 50 x 32 50 x 40
Size (In.)
xx * x xx * xx * 1x1x 1 x 1 x 1 2x2x1 1 x 1 x 1 x 1 2x 1x 1 x 1 x 1 x 1 2x 2 x 1 2 x 1
Part No.
M 7223 M 7341 M 7343 M 7342 M 7134 M 7161 M 7201 M 7552 M 7553 M 7554 M 7882 M 7442 M 7159 M 7123 M 7162 M 7883 M 7885 M 7886
Quantity (Case)
As required 300 As required As required 75 30 15 100 100 80 30 300 70 60 60 35 30 25
REDUCER ELBOW 90
Size (mm)
20 x 15 25 x 15 25 x 20 32 x 15 32 x 25 50 x 25
Size (In.)
x 1 x * 1 x * 1 x * 1 x 1 * 2 x1 *
Part No.
M 5341 N M 5151 M 5102 M 5141 M 5143 M 5241
Quantity (Case)
500 As required As required As required As required As required
12
* Reducer fittings are professionally assembled using Flowguard fittings and bushings. Quantity as per order. NOTE : Fabricated reducer fittings are not eligible for return to the manufacturer.
Application In Hospitals
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846
FEMALE ADAPTER
(CPVC Threads)
pw
MALE ADAPTER
(CPVC Threads)
Size (In.)
1 1 1 2
PartNo.
M M M M M M 6122 6342 6101 6205 6206 6201
Quantity (Case)
800 400 200 150 100 50
Size (In.)
1 1 1 2 Soc x MIP
PartNo.
M M M M M M M 6120 6340 6100 6105 B 6106 B 6200 B 6320
Quantity (Case)
600 600 300 150 100 50 500
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 9502 9503 9504 9505 9506 9508
Quantity (Case)
80 60 40 30 20 15
Size (In.)
Quantity (Case)
200 100
15 20 25 32 40 50
UNION
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 2502 2503 2504 2505 2506 2508
Quantity (Case)
200 150 100 80 50 30
CAP
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 3120 3340 3100 3105 3106 3200
Quantity (Case)
1000 500 200 100 80 40
13
(Brass Threads)
FEMALE ADAPTER
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS
COPPER - TUBE SIZE AS PER ASTM D-2846
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
PartNo.
M M M M M M 6123 6343 6103 6113 6153 6203
Quantity (Case)
200 150 50 25 25 15
Size (In.)
x x x x x x 1 x 1 x 1 x 1 x 1 1 x 1 x
PartNo.
M M M M M M 7722 7732 7733 7742 7755 7752
Quantity (Case)
200 100 125 75 30 40
BRASS COUPLING
Size (mm)
20 x 15 25 x 15
Size (In.)
X 1X
PartNo.
M 4732 M 4742
Quantity (Case)
200 100
MALE ADAPTER
(Brass Threads) Size (mm)
15 20 25 32 40 50 20 x 15
Size (In.)
1 1 1 2 Soc x MIP
PartNo.
M M M M M M M 6023 6033 6043 6053 6063 6083 6323
Quantity (Case)
200 100 50 25 25 15 150
Size (In.)
x x x 1 x 1 x 1x 1 1
PartNo.
M M M M M M 5702 N 5730 N 5703 N 5740 N 5704 N 5705 N
Quantity (Case)
200 150 100 100 50 30
14
Application In Corporates
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS
COPPER - TUBE SIZE AS PER ASTM D-2846
CONCEALED VALVE
(CHROME PLATED) Size (mm)
15 20
Size (In.)
PartNo.
M 1822-005 M 1822-007
Quantity (Case)
01 01
CONCEALED VALVE
(WHEEL TYPE) Size (mm)
15 20
Size (In.)
PartNo.
M 1822-005W M 1822-007W
Quantity (Case)
01 01
FABRICATED BAND
Size (mm)
20 25 32 40 50
Size (In.)
1
PartNo.
F12 - SOB F34 - SOB F1 - SOB
Quantity (Case)
150 200 150
Size (In.)
1 1 1 2
Size (In.)
1 1 1 2
PartNo.
M M M M M M 1922 - 005 1922 - 007 1922 - 010 1922 - 012 1922 - 015 1922 - 020
Quantity (Case)
80 120 50 40 30 15
Size (mm)
15 x 15 20 x 15
Size (In.)
x x
PartNo.
M 5120 SR N M 5341 SR N
Quantity (Case)
200 50
15
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 40 FITTINGS AS PER ASTM F- 438
TEE - Soc
Size (mm)
65 80 100
Size (In.)
2 3 4
PartNo.
M 401 - 025C M 401 - 030C M 401 - 040C
Quantity (Case)
12 08 04
90 ELBOW- Soc
Size (mm)
65 80 100
Size (In.)
2 3 4
PartNo.
M 406 - 025C M 406 - 030C M 406 - 040C
Quantity (Case)
15 10 06
CAP - Soc
Size (mm)
65 80 100
Size (In.)
2 3 4
PartNo.
M 447 - 025C M 447 - 030C M 447 - 040C
Quantity (Case)
10 10 10
Size (In.)
2 3 4
PartNo.
M 429 - 025C M 429 - 030C M 429 - 040C
Quantity (Case)
20 15 08
Size (In.)
2 2 2 3 3 3 4 4 4 x 1 x 1 x2 x 1 x2 x 2 x2 x 2 x3
PartNo.
M M M M M M M M M 437 - 290C 437 - 291C 437 - 292C 437 - 337C 437 - 338C 437 - 339C 437 - 420C 437 - 421C 437 - 422C
Quantity (Case)
25 25 25 20 20 20 10 10 10
65 80 100
16
Application In Hotels
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS
SCH - 80 FITTINGS AS PER ASTM - 439
TEE - Soc
Size (mm)
100 x 50 100 x 80 150 x 100 200 x 150 250 x 200 300 x 250
Size (In.)
* 4x 2 * 4x 3 * 6x 4 * 8x 6 *10 x 8 *12 x 10
PartNo.
801 - 420C 801 - 422C 801 - 532C 801 - 585C 801 - 628C 801 - 670C
Quantity (Case)
As required As required As required As required As required As required
Size (mm)
65 80 100 150 200 250 300
Size (In.)
2 3 4 6 8 * 10 * 12
PartNo.
M 801 - 025C M 801 - 030C M 801 - 040C M 801 - 060C M 801 - 080C 801 - 100C 801 - 120C
Quantity (Case)
12 07 04 02 01 01 01
Size (mm)
65 80 100
Size (In.)
2 3 4
Size (mm)
100 x 50 65 x 50 80 x 50 100 x 80 150 x 100 200 x 150 250 x 200 300 x 250 100 x 65 80 x 65
Size (In.)
4 2 3 4 6 8 * 10 * 12 4 3 x 2 x 2 x 2 x 3 x 4 x 6 x 8 x 10 x 2 x 2
PartNo.
M 837 - 420C M 837 - 292C M 837 - 338C M 837 - 422C M 837 - 532C M 837 - 585C 837 - 628C 837 - 670C M 837 - 421C M 837 - 339C
Quantity (Case)
20 50 35 20 06 03 01 01 10 35
PartNo.
M 836 - 025C M 836 - 030C M 836 - 040C
Size (mm)
65 80 100 150
Size (In.)
*2 *3 *4 *6
PartNo.
897 - 025C 897 - 030C 897 - 040C 897 - 060C
Quantity (Case)
05 05 05 03
Size (mm)
65 80 100
Size (In.)
2 3 4
PartNo.
M 835 - 025C M 835 - 030C M 835 - 040C
Quantity (Case)
30 20 15
17
*Trading Item
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 80 FITTINGS AS PER ASTM F-439 CAP Soc
Size (mm)
65 80 100 150 200 250 300
Size (In.)
* 2 * 3 * 4 * 6 * 8 *10 *12
PartNo.
847 - 025C 847 - 030C 847 - 040C 847 - 060C 847 - 080C 847 - 100CF 847 - 120CF
Quantity (Case)
10 10 06 03 01 01 01
COUPLING - Soc
Size (mm)
65 80 100 150 200 250 300
Size (In.)
2 3 4 6 8 * 10 * 12
PartNo.
M M M M M 829 - 025C 829 - 030C 829 - 040C 829 - 060C 829 - 080C 829 - 100C 829 - 120C
Quantity (Case)
20 15 12 02 01 01 01
Size (In.)
3 x 2 * 4 x 2 4 x 3 * 6 x 4 * 8 x 6 *10 x 8 *12 x 10 2 x 2 3 x 2 4 x 2
PartNo.
M 829 - 338 C 829 - 420 C M 829 - 422 C 829 - 532C 829 - 585C 829 - 628CF 829 - 670CF M 849 - 292 C M 829 - 339 C 829 - 421
Quantity (Case)
25 As required 15 As required As required As required As required 40 25 As required
90 ELBOW Soc
Size (mm)
65 80 100 150 200 250 300
Size (In.)
2 3 4 6 8 * 10 * 12
PartNo.
M M M M M 806 - 025C 806 - 030C 806 - 040C 806 - 060C 806 - 080C 806 - 100C 806 - 120C
Quantity (Case)
15 10 05 02 01 01 01
45 ELBOW Soc
Size (mm)
65 80 100 150 200 250 300
Size (In.)
* 2 * 3 4 * 6 * 8 *10 *12
PartNo.
817 - 025C 817 - 030C M 817 - 040C 817 - 060C 817 - 080C 817 - 100C 817 - 120C
Quantity (Case)
05 05 05 02 01 01 01
18
*Trading Item
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 80 FITTINGS AS PER ASTM F-439
Size (In.)
* 2 3 4 * 6 * 8 * 10 * 12
PartNo.
856 - 025C M 856 - 030C M 856 - 040C 856 - 060C 856 - 080C 856 - 100C 856 - 120C
Quantity (Case)
05 10 06 03 01 01 01
Size (In.)
* 2 3 4 * 6 * 8 *10 *12
Quantity (Case)
05 20 12 03 01 01 01
FLANGE Soc
Size (mm) Size (In.)
* 2 3 4 * 6 * 8 *10 *12
PartNo.
851- 025C M 851 - 030C M 851 - 040C 851 - 060C 851 - 080C 851 - 100C 851 - 120C
Quantity (Case)
05 15 12 03 01 01 01
Size (In.)
3 4
PartNo.
M 856 - 030-2C M 856 - 040-2C
Quantity (Case)
05 05
Size (In.)
2 3 4 6 8 *10 *12
PartNo.
M 854 - 025 C M 854 - 030 C M 854 - 040 C M 854 - 060 C M 854 - 080 C 854 - 100C 854 - 120C
Quantity (Case)
15 12 08 03 01 As required As required
Size (In.)
2 3 4 6 8 M M M M M
PartNo.
854 - 025 - 2C 854 - 030 - 2C 854 - 040 - 2C 854 - 060 - 2C 854 - 080 - 2C
Quantity (Case)
As Required As Required As Required As Required As Required
19
*Trading Item
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE Class 1 - PIPE SDR-11
pw
IS 15778
CM/L-3673470
IS 15778
CM/L-3673470
PIPE SCHEDULE 80
20
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS FLOWGUARD 1-STEP ADHESIVE SOLUTION (YELLOW)
Reduced VOC Emissions, NSF Listed ASTM F-493 N.B. For sizes 15 mm (") to 50 mm (2")
Size
50 ml 118 ml 237 ml 473 ml 946 ml
PartNo.
MTINS - 50 MTINS - 118 MTINS - 237 MTINS - 473 MTINS - 946
Quantity (case)
48 24 24 12 12
CPVC 724
N.B. For sizes 65 mm (2") and above
Size
473 ml 946 ml
PartNo.
IPS - 473 IPS - 946
Quantity (case)
12 12
PRIMER P70
N.B. Must use primer for 65 mm (2") & above
Size
118 ML 237 ML 473 ML 946 ML
PartNo.
EZ - 223 EZ - 222 EZ - 221 EZ - 220
Quantity (case)
24 24 12 12
21
CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS
PLASTIC STRAP
(mm)
15 20 25 32 40 50
Size
Size (In.)
1 1 1 2
Part No.
M 9120 M 9340 M 9100 M 9105 M 9106 M 9200
Quantity (case)
2500 2000 1200 600 500 300
METAL STRAP
Size (mm)
15 20 25 32 40 50
Size (In.)
1 1 1 2
Part No.
9120 9340 9100 9105 9106 9200 M M M M M M
Quantity (case)
100 100 100 50 50 50
END PLUG
Size (mm) 15
Size (In.)
Part No.
M PLUG -12 I
Quantity (case)
300
ELBOW HOLDER
(mm)
15 x 15 20 x 15
Size
Size (In.)
x x
Part No.
MH 12I MH - 12-34 N
Quantity (case)
200 200
Size (In.)
1 1 1 2
Part No.
9120 9340 9100 9105 9106 9200 MN MN MN MN MN MN
Quantity (case)
100 100 100 50 50 50
PUNCHARE KIT
Size(mm) (case)
15 20
TEE HOLDER
Size (mm) 20 x 15
Size (In.)
PartNo.
F12-PPK F34-PPK
Quantity
As required As required
Size (In.)
x
Part No.
M-T-H -34-12N
Quantity (case)
200
22
TECHNICAL DETAILS
Outside Diameters and Wall Thicknesses For CPVC 4120, SDR 11 Plastic Pipe As Per ASTM D-2846 Nominal Size
(in.) * 1 1 1 2 (mm) (15) (20) (25) (32) (40) (50)
Nominal Size
(in.) * 1 1 1 2 (mm) (15) (20) (25) (32) (40) (50)
Outside Diameters and Wall Thicknesses For CPVC 4120, SDR 13.5 Plastic Pipe Pressure Rating.PSI (Kg/Cm2) Wall Thickness, in. (mm) Outside Diameter, in.(mm)
Average 0.625 (15.9) 0.875 (22.2) 1.125 (28.6) 1.375 (34.9) 1.625 (41.3) 2.125 (54.0) Tolerance 0.003 (0.08) 0.003 (0.08) 0.003 (0.08) 0.003 (0.08) 0.004 (0.10) 0.004 (0.10) Minimum 0.055 (1.40) 0.065 (1.65) 0.083 (2.12) 0.102 (2.59) 0.120 (3.06) 0.157 (4.00) Tolerance + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.023 (0.58) 73.4F 320 320 320 320 320 320 (23C) (22.5) (22.5) (22.5) (22.5) (22.5) (22.5) 180F 80 80 80 80 80 80 (82C) (5.6) (5.6) (5.6) (5.6) (5.6) (5.6)
Outside Diameters, Wall Thickness & Pressure Rating For CPVC 4120, Schedule 40 Piping System As per ASTM F 441 Nominal Size (in.) (mm) 2 (65) 3 (80) 4 (100) Outside Diameter, in. (mm) Average Tolerance 2.875 (73.0) 0.007 (0.18) 3.500 (88.9) 0.008 (0.20) 4.500 (114.3) 0.009 (0.23) I.D. Average 2.444 (62.07) 3.041 (77.26) 3.998 (101.55) Wall Thickness, in. (mm) Minimum Tolerance 0.203 (5.16) + 0.024 (0.61) 0.216 (5.49) + 0.026 (0.66) 0.237 (6.02) + 0.028 (0.71)
Pipe - Pr. R. PSI (Kg/Cm2) Fitting - Pr. R. PSI (Kg/Cm2)
73.4F (23C) 73.4F (23C) 300 (21.10) 180 (12.65) 280 (18.28) 156 (10.96) 220 (15.47) 132 (09.28)
Pr. R. = Pressure Rating
Outside Diameters, Wall Thickness & Pressure Rating For CPVC 4120, Schedul 80 Piping System As per ASTM F 441 Pipe-Pr. R. Fitting-Pr. R. I.D. Nominal Size Wall Thickness, in. (mm) Outside Diameter, in. (mm) PSI (Kg/Cm2) PSI (Kg/Cm2) (in.) (mm) Average Tolerance Average Minimum Tolerance 73.4F (23C) 73.4F (23C) 2 (65) 2.875 (73.0) 0.007 (0.18) 2.288 (58.14) 0.276 (7.01) + 0.033 (0.84) 420 (29.53) 252 (17.71) 3 (80) 3.500 (88.9) 0.008 (0.20) 2.864 (72.75) 0.300 (7.62) + 0.036 (0.91) 370 (26.01) 222 (15.60) 4 (100) 4.500 (114.3) 0.009 (0.23) 3.778 (95.97) 0.337 (8.56) + 0.040 (1.02) 320 (22.50) 192 (13.49) 6 (150) 6.625 (168.3) 0.011 (0.28) 5.710 (145.04) 0.432 (10.97) + 0.052 (1.32) 280 (19.69) 168 (11.81) 8 (200) 8.625 (219.1) 0.015 (0.38) 7.565 (192.15) 0.500 (12.70) + 0.060 (1.52) 250 (17.57) 150 (10.54) 10 (250) 10.750 (273.1) 0.015 (0.38) 9.493 (241.12) 0.593 (15.06) + 0.071 (1.80) 230 (16.17) 138 (09.70) 12 (300) 12.750 (323.90) 0.015 (0.38) 11.294 (286.87) 0.687 (17.45) + 0.082 (2.08) 230 (16.17) 138 (09.70)
Pr. R. = Pressure Rating
Temperature Derating Factors 90 100 120 140 Working Temperature (F) 73-80 Working Temperature (C) 23-25 32 38 49 60 Pipe Derating Factor 1.00 0.91 0.82 0.65 0.50 Valve Derating Factor 1.00 0.95 0.90 0.80 0.70
N.B. : For obtaining working pressure in system, multiply the maximum pressure with derating factor at the working temperature of system. * Valves, Unions & Speciality Products have different elevates temperature rating than pipe.
23
45
J J
Tapered Socket Dimensions For CPVC 4120, SDR 11, Plastic Pipe Fittings AS PER ASTM D2846
Nominal Size (in.)
1 1 1 2
(mm)
(15) (20) (25) (32) (40) (50)
Wall Thickness in. (mm) Socket Socket Enterance Bottom "EA" min. "EB" min. "F"
0.068 0.080 0.102 0.125 0.148 0.193 (1.73) (2.03) (2.59) (3.18) (3.76) (4.90) 0.102 0.102 0.102 0.125 0.148 0.193 (2.59) (2.59) (2.59) (3.18) (3.76) (4.90) 0.128 0.128 0.128 0.156 0.185 0.241 (3.25) (3.25) (3.25) (3.96) (4.70) (6.12)
450 G G J
AMERICAN NATIONAL STANDARD TAPER PIPE THREADS (NPT) ANSI STANDARD B1.20.1 ASTM STANDARD F 1498 Effective Thread Pitch of Nominal Size Threads Length Thread (mm) (in.) Per in. P L
15 20 25 32 40 50 65 80 100 1 1 1 2 2 3 4 14 14 11 11 11 11 8 8 8 0.5337 0.5457 0.6828 0.7068 0.7235 0.7565 1.1375 1.2000 1.3000 0.07143 0.07143 0.08696 0.08696 0.08696 0.08696 0.12500 0.12500 0.12500
Minimum Dimensions from Center to End of Socket (Laying Length) for CPVC 4120, SDR 11 Plastic Tubing Fittings* per ASTM D 2846
Nominal (G) Min. (J) Min. Size 0.382 0.183 0.507 0.235 1 0.633 0.287 1 0.758 0.339 1 0.884 0.391 2 1.134 0.495 (N) Min. 0.102 0.102 0.102 0.102 0.102 0.102
NPT
BSPT
BSP ISO 7/1 PARALLEL THREADS Effective Thread Pitch of Nominal Size Threads Length Thread (mm) (in.) Per in. P L
15 20 25 32 40 50 65 80 100 1 1 1 2 2 3 4 14 14 11 11 11 11 11 11 11 13.152 14.514 16.714 19.050 19.050 23.378 26.698 29.873 35.791 1.8143 1.8143 2.3091 2.3091 2.3091 2.3091 2.3091 2.3091 2.3091
BASIC SOCKET DIMENSIONS SCHEDULE 40 CPVC FITTINGS AS PER ASTM F 438 SCHEDULE 80 CPVC FITTINGS AS PER ASTM F 439 Socket Length Diameter (in.) Nominal Size Socket Socket Minimum C (in.) Bottom (mm) (in.) Entrance Tolerance SCH 40 SCH 80 A B
65 80 100 150 200 250 300 2 3 4 6 8 10 12 2.889 3.516 4.518 6.647 8.655 10.780 12.780 2.868 3.492 4.491 6.614 8.610 10.735 12.735 0.007 0.008 0.009 0.011 0.015 0.015 0.015 1.750 1.875 2.000 3.000 4.000 5.000 6.000 1.750 1.875 2.250 3.000 4.000 5.000 6.000
24
900 Standard Elbow 1.55 2.06 2.62 3.45 4.03 5.17 6.10 7.60 10.00 15.10 19.90 24.90 29.70
450 Standard Elbow 0.83 1.10 1.40 1.84 2.15 2.76 3.30 4.10 5.30 8.00 10.60 13.30 15.90
Standard Standard TEE TEE Run Flow Branch Flow 1.04 3.11 1.37 4.12 1.75 5.25 2.30 6.90 2.68 8.05 3.45 10.30 4.10 12.20 5.10 15.20 6.70 20.00 10.10 30.20 13.20 39.70 16.60 49.90 19.80 59.40
( )
1.852
g1.852 d4.8655
Friction head in feet of water per 100 feet of pipe Inside diameter of pipe in inches Flow rate in gallons per minute pipe surface roughness constant
Constant (C)
150 130-140 125 120 60 - 80 -
Type of Pipe
CPVC pipe, new-40 years old steel / cast iron pipe, new steel pipe, old cast iron, 4 - 12 years old galvanized steel cast iron, 13 - 20 years old cast iron, worn / pitted
The value in the following tables are based on this formula at 730F and the assumption that water flowing at a given rate of gallons per minute is suddenly completely stopped. At 180F, the surge pressure is approximately 15% less. The value for fluids other then water may be by multiplying by the square root of the fluids specific gravity. THE WATER HAMMER SURGE PRESSURE PLUS THE SYSTEM OPERATING PRESSURE SHOULD NOT EXCEED 1.5 TIMES THE RECOMMENDED WORKING SEPARATE RATING OF THE SYSTEM. In order to minimize hydraulic shock due to water hammer, linear fluid flow velocity should generally be limited to 5ft/s, particularly for pipe size of 6 or longer. Velocity at system start-up should be limited to 1 ft/s during filling until it is certain that all air has been brought up to operating conditions. Air should not be allowed to draw in air. Where necessary, extra protective equipment may be used to prevent water hammer damage, shock absorbers, surge arrestors and vacuum air relief valves.
25
Friction Loss and Flow velocity for SDR 11 CTC CPVC Thermoplastic Pipe
(Friction head and Friction Loss are per 100 feet of pipe) NOTICE : Flow velocity should not exceed 5 feet per second. Velocities in excess of 5 feet per second may result in system failure and property damage.
Head Loss Feet of Water Per 100 Ft. Head Loss Feet of Water Per 100 Ft. Head Loss Feet of Water Per 100 Ft. Head Loss Feet of Water Per 100 Ft. Head Loss Feet of Water Per 100 Ft. Pressure Loss PSI Per 100 Ft. Pressure Loss PSI Per 100 Ft. Pressure Loss PSI Per 100 Ft. Pressure Loss PSI Per 100 Ft. Pressure Loss PSI Per 100 Ft. Velocity Feet Per Second Velocity Feet Per Second Velocity Feet Per Second Velocity Feet Per Second
10 3.23 4.84 6.46 14.23 21.51 30.15 40.11 51.37 63.89 16.14 17.75 77.66 92.65 8.07 9.68 11.30 12.91 14.52 8.35 3.62 6.17 9.33 13.07 17.39 22.27 27.70 33.66 40.16 3.94 1.71 75.78 129.11 12.04 14.45 16.86 106.19 46.03 79.82 34.60 56.94 24.69 55.97 9.63 37.67 16.33 32.85 7.22 22.11 9.58
15
20
25
30
35
40
45
50
55
60
70
80
90
100
125
1 /2 in.
1.71
3.19
1.38
0.80
3.42
11.53
5.00
1.60
5.16
24.43
10.59
2.40
6.83
41.62
18.04
3.20
8.54
62.91
27.27
4.00
0.06
10.25
88.18
38.23
4.79
11.96
117.32
50.86
5.59
13.67
150.23
65.13
6.39
15.38
186.85
81.00
7.19
17.08
227.11
98.45
7.99
0.21 0.45 0.76 1.15 1.62 2.15 2.75 3.42 4.16 4.96 5.83 7.76 9.93 12.35 15.02 22.70
11.99
15.98
26
27
2.5" 4"
(Independent variables : Gallons per minute and nominal pipe size O.D. Dependent variables : Velocity, Friction head and pressure drop per 100 feet of pipe, interior smooth.)
3"
CAUTION : Flow velocity should not exceed 5 feed per second. CPVC pipe can not be used for compressed air service.
(Independent variables : Gallons per minute and nominal pipe size O.D. Dependent variables : Velocity, Friction head and pressure drop per 100 feet of pipe, interior smooth.)
2 1/2 in.
3 in. 4 in.
6 in.
8 in.
10 in.
12 in.
28
CAUTION : Flow velocity should not exceed 5 feed per second. CPVC pipe can not be used for compressed air service.
Fixed Point
Lo
op
Guidehanger
L=
Where: L = E = S = D = L =
3 ED ( L ) 2S
Loop Length (in.) Modululs of elasticity at maximum temperature (psi) Working stress at maximum temperature (psi) Outside diameter of pipe (in.) Change in length due to change in temperature (in.)
29
LOOP
X = 2L/5 Y = L/5
2 =X 5
OFFSET
4
6' MIN
Y=
6' MIN 4
Modulus of Elasticity and Working Stress for CPVC Temperature Modulus,E(psi) Stress, S(psi) F (C) 73 (27) 423,000 2000 90 (32) 403,000 1800 110 (43) 371,000 1500 120 (49) 355,000 1300 140 (60) 323,000 1000 160 (71) 291,000 750 180 (82) 269,000 500
TABLE A
Change of Direction
Long Run of Pipe
Flowguard CPVC pipe CTS PIPES (ASTM D 2846) Calculated Loop (Offset) Length with T of approx. 80F in inches Nominal Pipe size mm in. 15 20 25 1 32 1 40 1 50 2 Length of Run in feet 40 22 26 29 32 35 40 60 27 32 36 40 43 49 80 31 36 41 46 50 57 100 34 41 46 51 56 64
3rd Floor
2 5
TABLE B
Flowguard CPVC IPS PIPES (ASTM F 441) Calculated Loop (Offset) Length with T of approx. 80F in inches
6' MIN
2nd Floor
Loop
Fixed Point
1st Floor
Guide/ hanger
Ground Floor
6' MIN
30
21C (70F)
Ft. (167.70) (167.70) (182.88) (198.12) (213.36) (213.36) (244.00) (244.00) (274.32) (304.80) (335.28) (350.52) (381.00)
71C (160F)
(cm) 3.0 3.0 3.5 3.5 3.5 4.0 4.5 4.5 5.0 5.5 6.0 6.5 7.5
82C (180F)
Band Hanger
Anchor Strap
Ft. (cm) (91.44) 2.5 (76.20) (91.44) 2.5 (76.20) (106.68) 3.5 (91.44) (106.68) 3.5 (106.68) (106.68) 3.5 (106.68) (121.92) 3.5 (106.68) (137.16) 4.0 (121.92) (137.16) 4.0 (121.92) (152.40) 4.5 (137.16) (167.07) 5.0 (152.40) (182.88) 5.5 (167.07) (198.12) 6.0 (182.88) (228.60) 6.5 (198.12)
Pipe Clamp
U-Bolt
Ball valve
Tap
31
UNDERGROUND INSTALLATION
CPVC pipes and fittings can be installed underground. Since these piping systems are flexible systems, proper attention should be given to burial conditions. The stiffness of the piping system is affected by sidewall support, soil compaction, and the condition of the trench. Trench bottoms should be smooth and regular in either undisturbed soil or a layer of compacted backfill. Pipe must lie evenly on this surface throughout the entire length of its barrel. Excavation, bedding and backfill should be in accordance with the provision of the local Plumbing Code having jurisdiction.
TRENCHING
The following trenching and burial procedures should be used to protect the piping system. 1. The trench should be excavated to ensure the sides will be stable under all working conditions. 2. The trench should be wide enough to provide adequate room for the following : A. Joining the pipe in the trench. B. Snaking the pipe from side or side to compensate for expansion and contraction. C. Filling and compacting the side fills. The space between the pipe and trench wall must be wider than the compaction equipment used in the compaction of the back fill. Minimum width shall not be less than the greater of either the pipe outside diameter plus 16.inches or the pipe outside diameter times 1.25 plus 12 inches. Trench width may be different if approved by the design engineer. 3. The trench bottom should be smooth, free of rocks and debris, continuous, and provide uniform support. If ledge rock, hardpan or large boulders are encountered, the trench bottom should be padded with bedding of compacted granular material to a thickness of at least 4 inches. Foundation bedding should be installed as required by the engineer. 4. Trench depth is determined by the pipes service requirements. Plastic pipe should always be installed at least below the frost level. The minimum cover for lines subject to heavy overhead traffic is 24 inches. 5. A smooth trench bottom is necessary to support the pipe over its entire length on firm stable material. Blocking should not be used to change pipe grade or to intermittently support pipe over low sections in the trench.
32
HANDLING :
The pipe should be handled with reasonable care. Because thermoplastic pipe is much lighter in weight than metal pipe, there is sometimes a tendency to throw it around. This should be avoided. The pipe should never be dragged or pushed from a truck bed. Pallets for pipe should be removed with a fork lift. Loose pipe can be rolled down timbers as long as the pieces do not fall on each other or on any hard or uneven surface. In all cases, severe contact with any sharp objects (rocks, angle irons, forks on forklifts, etc.) should be avoided.
Where Q = Heat loss per meter of pipe, W/m = Thermal conductivity. [W/mk] for CPVC, = 0.14 w/mk e = Thickness of pipe, mm .068 II = 3, 1416 di = Inside diameter, mm = Temperature differential between inner and outer surface of pipe. This can be approximated to : T water. T ambient (K)
STORING :
If possible, pipe should be stored inside. When this is not possible, the pipe should be stored on level ground which is dry and free from sharp objects. If different schedules of pipes are stacked together, the pipes with the thickest walls should be at the bottom. The pipes should be protected from the sun and be in an area with proper ventilation. This will lessen the effects of ultraviolet rays and help prevent heat built-up. If the pipes are stored in racks, it should be continuously supported along its length. If this is not possible, the spacing of the supports should not exceed three feet (3). When storage temperatures are below 0C (32F), extra care should be taken when handling the pipe. This will help prevent any problems which could be caused by the slightly lower impact strength of PVC pipes at temperature below freezing.
Example :
What is the heat loss/meter from a 20mm outside diameter CPVC pipe. wall thickness 2,3mm, with water flowing inside at 800C and an ambient air temperature of 250C?
20 + 15.4 . (80-25) 2
Equation (1) can be simplified for standard pipe dimensions to : Q =K Where K is a conductivity of CPVC and the pipe geometry in the previus example. do = 20mm, and e = 2.3mm K = 0.14 . 3,1416 2.3
33
In order to make a proper and neat joint, measure the pipe length accurately and make a small mark. Ensure that the pipe and fittings are size compatible. You can easily cut with a wheel type plastic pipe cutter or hacksaw blade. Cutting tubing as squarely as possible provides optimal bonding area within a joint.
CUTTING
Burrs and filings can prevent proper contact between tube and fitting during assembly and should be removed from the outside and inside of the pipe. Debarking tool, pocket knife or file are suitable for this. A slight bevel on the end of the tubing will ease entry of the tubing into the fitting socket.
2 3
DEBURRING / BEVELING
ASSEMBLY
5 4
SOLVENT CEMENT APPLICATION
FITTING PREPARATION
Using a clean, dry rag, wipe dirt and moisture from the fitting sockets and tubing end. The tubing should make contact with the socket wall 1/3 to 2/3 of the way into the fitting socket.
Immediately insert the tubing into the fitting socket, rotate the tube to turn while inserting. This motion ensures and even distribution of cement within the joint. Properly align the fittings. Hold the assembly for approximately 10 seconds, allowing the joint to set-up.
use only CPVC cement or an all - purpose cement conforming to ASTM F 493 or joint failure may result. When making a joint, apply a heavy, even coat of cement to the pipe end. Use the same applicator without additional cement to apply a thin coat inside the fitting socket. Too much cement can cause clogged water ways.
Note : For sizes above 65 mm (2") use IPS 70 primer before applying solvent cement. The purpose of a primer is to penetrate and soften the surfaces so they can stick together. The proper use of a primer ensures that the surfaces are prepared for fusion in a wide variety of weather conditions.
34
BEFORE BEGINNING :
1. 2. Verify the cement is the same as the pipes and fittings being used. Check the temperature where the cementing will take place.
Pipe Size Pipe Size Pipe Size Pipe Size 1 1/4 1 1/2 to 3 4to 8 10 to 12 15 mm 40 mm 100 mm 250 mm to to to to 32 mm 80 mm 200 mm 300 mm 15 min 30 min 1 hrs. 2 hrs. 1 hrs. 2 hrs. 4 hrs. 8 hrs.
Cement take longer time to set up in cold weather. Be sure to allow extra time for curing. Do not try to speed up the cure by artificial means this could cause porosity and blisters in the cement film.
Pipe Size Pipe Size 1 1/4 1 1/2 to 3 15 mm 40 mm to to 32 mm 80 mm 6 hrs. 12 hrs. 12 hrs. 24 hrs.
Solvents evaporate faster in warm weather. Work quickly to avoid the cement setting up before the joint is assembled. Keep the cement as cool as possible. Try to stay out of direct sunlight.3. Keep the lid on cements, cleaner, and primers when not is use Evaporation of the solvent will effect the cement.4. Stir or shake cement before using. 5. Use 20 mm (") dauber on small diameter pipes,40 mm (1") dauber up through 80 mm (3") pipe, and a natural bristle brush, swab, or roller the pipe diameter on pipes 4" and up. 6. Do not mix cleaner or primer with cement. 7. Do not use thickened or lumpy cement. It should be like the consistency of syrup or honey. 8. Do not handle joints immediately after assembly. 9. Do not allow daubers to dry out. 10. Maximum temperature allowable for CPVC pipe is 180F. 11. All coloured cements, primers, and cleaners will have a permanent stain. There is no known cleaning agent. 12. Use according to the step outline in ASTM D-2846, joining of pipe and fittings.
35
IMPORTANT NOTES
WATER HEATER CONNECTIONS
*Approximate numbers of joints which can be made per ltr. of solvent cement * For primer, number of joints are approximate double than solvent cement
Some plumbing codes contain detailed requirements for connections to gas or electric storage type water heaters. Determine whether your code has such requirements and satisfy
them. If no detailed requirements exist, use the following information. On electric water heaters CPVC can be piped directly to the heater with special metal- to- CPVC transition fittings (photo L). On gas water heaters there should be at least 6 inches of clearance between the exhaust flue and any CPVC piping (photo K). Twelve inch long metal nipples or appliance connector should be connected directly to the heater so that the CPVC tubing cannot be damaged by the build-up of excessive radiant heat from the flue. An approved temperature/pressure (T/P) relief valve should be installed so that the probe or sensing element is in the water at the top of the heater. CPVC is approved by all the model codes for use as relief valve drain line piping. Use a metal-toCPVC transition fitting to connect to the relief valve and continue the pipe full size to the outlet. For horizontal runs, slope the pipe towards the outlet and support it at three-feet centers or closer. The pipe must discharge to the atmosphere at an approved
fittings are being joined in enclosed areas, the use of ventilating devices are advised
Keep cements, primers and cleaners away from all sources of ignition, heat, sparks and open flame. Keep containers of cements, primers and cleaners tightly closed except when the product is being used. Dispose of all rags used with solvents in a proper outdoor waste receptacle. Avoid eye and skin contact. In case of eye contact, flush with plenty of water for 15 minutes and call a physician.
THREAD SEALANTS
Threaded CPVC fittings with tapered pipe threads (e.g. male thread adapters) must be used with a suitable thread sealant to insure leak-proof joints. Over the years, PTFE (Teflon or equivalent) tape has been the preferred thread sealant, it is still the most widely accepted and approved sealant. Some paste sealant can affect CPVC fittings; manufacturer should be used. therefore only sealants recommended for use with CPVC by the thread sealant
location. Do not use CPVC pipe and fittings with commercial-type, non-storage water heaters.
36
DO's
1. 2. 3. 4. 4A. Install product according to ASTRAL's Installation instructions and manual and follow recommended safe work practices. Keep Pipe and Fittings in original packaging until needed and store pipes in covered areas. Use tools designed for use with plastic pipe and fittings. Cut-off minimum 25 mm beyond the edge of the crack in case any crack is discovered on the pipe. Pipe may be cut quickly and efficiently by several methods. Wheel-type plastic tubing cutters are preferred. Ratchet type cutters or fine tooth saws are another option. However, when using the ratchet cutter, be certain to score the exterior wall by rotating the cutter blade in a circular motion around the pipe. Do this before applying significant downward pressure to finalise the cut. This step leads to a square cut. In addition, make sure ratchet cutter blades are sharp. Cutting tubing as squarely as possible provides optimal bonding area within a joint. Burrs and filings can prevent proper contact between the tube and fittings during assembly, and should be removed from the outside and inside of the tube. A chamfering tool is preferred, but a pocket knife or file is also suitable for this purpose. Use CPVC Cement only. Use only CPVC Cement or an all purpose cement conforming to ASTM F-493 or joint failure may result. Always conduct hydraulic pressure testing after installation to detect any leaks and faults. Wait for appropriate cure time before pressure testing. Fill lines slowly and bleed air from the system prior to pressure testing. Rotate the pipe 90 to 180 to spread the CPVC Solvent Cement evenly in the joint while pushing the Pipe into Fitting. Use Teflon tapes with threaded fittings. Ensure that there are no sharp edges in contact with the pipe while embedding the pipes on the walls or in the floors. When making a transition connection to metal threads, use a special transition fitting or CPVC male threaded adapter whenever possible. Do not over-torque plastic threaded connections. Head tight plus one-half turn should be adequate. Provide Vertical & Horizontal Supports as recommended using the Plastic Straps only. Apply a water- based paint only on exposed pipes & fittings. Visually inspect all joints for proper cementing at the end of shift or day. A Visual inspection of the complete system is also recommended during pressure testing. 12. When connecting to a gas water heater, CPVC tubing should not be locat ed within 50cm of the flue. For water heaters lacking reliable temperature control, this distance may be increased up to 1m. A metal nipple or flexible appliance connector should be utilized. This measure eliminates the potential for damage to plastic piping that might result from excessive radiant heat from the flue. 13. Use of a brass/CPVC transition adapter when connecting CPVC to a water heater will help facilitate water heater replacement in the future. 14. Pressure test CPVC systems in accordance with local code requirements.
4B.
4C.
5.
DON'T's
1. Do not use Metal Hooks or Nails to support / hold or put pressure on the pipes. Do not use straps & hangers with rough or sharp edges. Do not tighten the straps over the pipes. 2. Never expose the pipe to Open Flame while trying to bend it. 3. Do not drop pipes on edges from heights. Do not drop heavy objects on pipes or walk on pipes. 4. Do not dilute Solvent Cement with Thinners /MTO or any other liquid etc. 5. Do not use air or gases for pressure testings. 6. Do not use any other petroleum or solvent- based sealant, adhesive, lubricant or fire stop material on CPVC pipes and fittings. 7. Do not use CPVC Pipes & Fittings for pneumatic applications.
6.
7. 8. 8A.
9. 10. 11.
37
NOTES
38
CPVC PIPING SYSTEM FOR INDUSTRIES CPVC PIPING SYSTEM FOR FIRE SPRINKLERS ULTRADRAIN CONVENTIONAL SYSTEM ASTM uPVC PIPING SYSTEM DRAINAGE SYSTEMS LIGHT WEIGHT FOAMCORE uPVC PIPES LEAD FREE & HEAVY METAL FREE COLUMN PIPES FOR SUBMERSIBLE PUMPS MULTI-LAYER COMPOSITE PIPE LEAK PROOF uPVC DRAIN WASTE & VENT SYSTEM uPVC PIPES FOR DRAINAGE & SEWERAGE APPLICATIONS THE LEADING SOUNDPROOF SOIL & WASTE SYSTEM BATHROOM WITHOUT COMPROMISE
Authorised Distributor :
All information contained in this manual is given in good faith and believed to be accurate and reliable. But because of many factors which are outside our knowledge and control and affect use of product, no warranty is given or is to be implied with respect to such information, nor we offer any warranty of immunity against patent infringement. No responsibility can be accepted for any error, omissions or incorrect assumptions. Any specification can change without prior notice.