GENERAL INFORMATION
This Panel-Mount Digital Timer series can be produced for wide range of power supply sources, from 240Vac to 12Vdc, output format can be produced with either volt-free or volt-ouput. Optional, either replaceable Lithium CR2032 or rechargeable V80H are equipped with Timer to provide programming memory backup.
PROGRAMMING THE TIMER #1
A .Functional description to buttons on panel
1. TIMER : Programs review & setting programs 2. MANUAL : To select ON , AUTO or OFF 3. CLOCK : To adjust current DAY and TIME 4. Day : To adjust day of week 5. HOUR : To adjust Hour 6. MIN : To adjust minute 7. P : Reset Timers setting 8. LED : To indicate ON/OFF status
TM-619-series
Press P button to reset Timer before programming B.Adjusting CLOCK Press and hold CLOCK and then press DAY key, HOUR key, MIN key respectively to adjust clock of Timer to accurate DATE, HOUR, MINUTE . In 12-Hour-Format, PM & AM shall appear on LCD screen. In 24-Hour-Format LCD screen shall indicate 0:00 ~23:59 C. Start to programming the TIMER 1. Press TIMER key. LCD screen shall show
This Digital Timer is accurate to the minute, designed with either 6 or 8 ON/OFF(event) per day Graphic description, as below:
1 ~ 6/8 ON 1 ~ 6/8 OFF Program Input(Command)
Timers Output
ON
- - : - -
--
Also ,it provides 15-combination of Daily-Programs which can leads great convenience to users upon choosing desired DAYS of WEEK. 1. MO TU WE TH FR SA SU
2. MO 3. TU
4. 5. 6. WE TH FR
2. Press DAY key to select any of 15-combination of Daily-Programs to your application demand. Continuing to press DAY key, LCD shall alternating indicate among 15-combinations. 3. Press HOUR , MIN respectively to set desired Hour and Minute for 1ON 4. After finished setting of 1 , Press TIMER key again, OFF shall appear on LCD screen. 1 --:-ON
7. 8. 9. MO TU WE TH 10. 11. MO TU WE TH 12. MO TU WE 13. TH 14. MO 15. TU WE TH FR
SA SU SA SU FR SA FR SA FR SA
--
5 . Press DAY key to select any of 15-combination of Daily-Programs to your application demand. Continuing to press DAY key, LCD shall alternating indicate among 15-combinations. Day-combination chosen in each of ON/OFF program-period must be consistent. 6.Repeat Programming procedure 3 to set desired Hour & Minute for 1OFF 7. When finished setting 1ON & 1OFF, Press TIMER ,
2
ON
DESCRIPTIONS TO MODEL CODE
Advise factory upon ordering, for requirements of 6 or 8 ON/OFF 12H or 24H clock format Lithium CR2032 or Rechargeble V80H : Volt-Free contact, 250Vac/16Amp Rating H : Volt Output, 250Vac/20Amp Rating L : Volt Output, 250Vac/16Amp Rating
- - : - -
--
shall appear on LCD screen.
8. Repeat programming procedure above to complete rest of ON/OFF program-period(event)
2 - - : - - -8 - - : - - --or just to the desired number of ON/OFF(event) setting for demand of practicable application.
ON
--:--
OFF
OFF
1 - - : - - -2 - - : - - -1 - - : - - -5 - - : - - -9.When finished program-setting(event), press CLOCK , Timer shall start to execute programs.
ON
OFF
ON
OFF
TM-619 --1~4 Timers Model Number
TM-619H--1~4
TM-619L--1~4 D. To review programs Keep to press TIMER , display on LCD screen shall alternating display among each of 6 or 8 ON/OFF
1 ~ 4 Power supply for Timer 1: 120Vac main supply 2: 240Vac main supply 3: 24Vac/Vdc 4: 12Vdc
E. How to use OVERRIDE functions 619-programming-modeTimer is designed with 2 Override function, so as to widen its usage upon practicable application. Override function is effective only when Timer is running under AUTO mode.
Temporary-Override --- Follow procedure below:
Condition-1 When Timers output status is ON Pressing MANUAL key, to move indicator from AUTO to OFF, Timer output shall turn to OFF status, programs overrided. Pressing MANUAL again to switch Timer status to AUTO , Timers output shall continue maintaining OFF . Timer shall resume its automatic operation when next program(event) calls for ON . (With next opposite set point). Condition-2 When Timers output status is OFF Pressing MANUAL key, to move indicator from AUTO to ON, timer output shall turn to ON status, programs overrided. Pressing MANUAL again to switch Timer status to AUTO , Timers output shall continue maintaining ON . Timer shall resume its automatic operation when next program(event) calls for OF . (Until next opposite set point) R andom-Start-Up Override Press and hold DAY P key and then press MIN key. There shall be a symbol shows on left corner of LCD screen, to indicate this Override in executing. When this Override is being executed, the original programs will be stopped, and once every 10 to 120 minutes Timers shall automatically turn its output to ON status. In practicable application which is applied to home-use, this Override function also called Anti-Burglar Override. Once again to press and hold DAY key, and then press MIN key shall terminate this Override. Remark: 1. For voltage and electrical RATING information, please refer to the markings on the back of timer. 2. See the back of timer for proper wire connections. 3.Timer may need to be connected to power source in order to set the program. Follow graphic description below & Refer to section of Descriptions to Model Code on this instruction-sheet upon proceeding electrical wiring.
HOW TO REPLACE BATTERIES