1900MHz Digital Band Selective Repeater
RX-1939
Features
Total 4 pass band segments with independent ON/OFF for maximum flexibility. 5W/10W total output power. Integrated wireless modem for remote configuration, monitoring and control. Internal backup battery keeps the alarm unit running for up to two hours after power failure. Compatible to Comba generic OMT and OMC platform. Designed for all weather outdoor installation waterproof, damp-proof and omni-sealed (IP65).
Functional Block Diagram
DL LNA
DL CHANNEL 1 DL CHANNEL 2 DL CHANNEL 3 DL CHANNEL 4
DL PA
Mobile Ant MT
Mobile
UL LNA
Donor Ant BTS DT
UL PA
Digital Frequency Selective Module
UL CHANNEL 1 UL CHANNEL 2 UL CHANNEL 3 UL CHANNEL 4
OMT Computer with Data card Modem
Alarm Indicator
Main Control Unit
Power Supply
Li-ion BATT
Wireless Modem
OMC
OMT
External Power
Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com 5W10W
Issued: 27Jun12 Control: 0-0-0 1/3
1900MHz Digital Band Selective Repeater
RX-1939
Preliminary Technical Specifications Electrical
Operating Frequency, Uplink Operation Frequency, Downlink Operating Bandwidth Per Sub-band Sub-bands Output Power, Uplink Total Output Power, Downlink System Gain Downlink System Gain Uplink Gain Adjustment Range (1dB step) Pass Band Ripple, p-p Uplink Noise Figure System Group Delay Intermodulation Spurious Out-of-Band Rejection Input VSWR Absolute Maximum RF Input Power, Downlink Impedance dBm 9kHz-1GHz 1GHz-12.75GHz 600kHz 1MHz dBm dBm dB dB dB dB dB sec dBc dBm dBc 37 90 90 0 30 6 5 6.5 40 -36dBm -30dBm -45 -60 1.5 +10 50 MHz MHz MHz 5W 1850 - 1910 1930 - 1990 0.2-25 adjustable 4 30 40 10W
Power, Mechanical & Environmental
Dimensions, H x W x D Weight (approx.) Power Supply Power Consumption (approx.) Power Up Waiting Time (approx.) MCU Battery Backup Time (approx.) Enclosure Cooling RF Connectors Operating Temperature Operating Humidity Environmental Class MTBF hr C mm 430 x 300 x 164 18 100-240 / 47-63Hz 160 180 2 Convection N-Female -33 to +55 95% IP65 50,000 Note: Typical specification at room temperature
kg
VAC W sec hr
Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com 5W10W
Issued: 27Jun12 Control: 0-0-0 2/3
1900MHz Digital Band Selective Repeater
RX-1939
Operation and Maintenance
Using a direct connection to a PC by RJ45, installation and commissioning of the RX-1939 is accomplished by the OMT. Using the integrated wireless modem (data or SMS mode), the equipment parameters can be monitored and controlled remotely. Controlled equipment parameters include: Equipment ID, Phone Number, Sampling Time, Operating Band Switch, Channel No. Range, ATT, PA Switch, Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report Enable. Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Chassis Lock, DL Output Power Low, DL Input power Overload, Over Temp, DL VSWR, Battery Low), DL Output Power and DL Input Power. The RX-1939 has been developed to take advantage of advanced network operation, where the OMC (optional) provides an effective solution for central monitoring of a group of Comba products.
Outline Drawing
RUN ALM MODEM
AC 100V-240V 50/60Hz
AC OUT RS-485 EXT_ALM MODEM ANT
DT
MT
Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com 5W10W