Summit 8800
Digital Flow Computer with graphic display
Lower OPEX and CAPEX by using modern communications and modular design Easier engineering using multi-level software and slot-in hardware expansion More effective maintenance and operation using colour graphics touch-screen and on-line communications Minimized service cost and automatic remote metering with unsurpassed network support More consistent accuracy and reduce re-calibrations through automatic performance monitoring
SUMMIT 8800
Specifications
General
Chassis Half width 3U high 19 construction Panel or chassis mount Dimensions 130 x 210 x 240 mm (h x w x d) Accommodates up to 6 plug-in cards
Power supply
Supply voltage 22 to 28 V DC 8.5 W (15 W fully loaded) Protection 3.15 A fuse Auxiliary Outputs 24 V 200 mA Operating Temperature 0...50 C (32...120 F) Storage Temperature -20...70 C (0...160 F) Operating Humidity to 90% non-condensing Weight approximately 2.0 kg / 4.5 lbs (2.5 kg / 5 lbs full loaded)
Operating
Rear Panel
Field connections PSU connections and fuse Six slots for option boards I/O and Communication Connections Access to Security Mode switches Access to Memory Card: SD up to 2 GBytes
Switch Panel
Front panel display
Display 5.7 Colour graphics VGA screen Touch Panel 360 Rotary menu navigation Local Language Support 5 x High Brightness Indicator LEDs Front Panel USB connection
Security*
Personalized electronic key Colour keys with multi-level security
Various
Configuration Menu-based configuration program Optional Advanced block diagram (APB Application Builder)* Optional FC language interpreter Local Data Downloading via USB Local Diagnostics and re-programming
Approvals
Compliant with all international approvals, including - MID European approval - OIML R117 - NMi metrology requirement RS232/485 Ethernet 10/100 Mbs I/O board Power in Power out RJ45 RJ45 Weidmller non-screw type 36-way Part 1748640000 Weidmller connector Part 1727570000 Weidmller connector Part 1597370000
Connectors
*available 2009
SUMMIT 8800
Hart I/O Board
Serial Communication Connection RS232/RS485 Speeds up to 38400 baud, software handshake Modbus Master/Slave communication For meters (ultrasonic, Coriolis), GC and analysers DC to 5 kHz, optically isolated ISO 6551 or API Chapter 5.5 Level A Turbine, density, status or detector switch max, Input voltage + 24 Vdc or 1.2 Vdc
Pulse Counting/ Frequency Inputs/ Status Inputs
Switch / Valve Status Inputs HART transmitter loops
Optically isolated, 24 Vdc, 25 mA Up to 3 transmitters for each loop For temperature, (differential) pressure For multivariable transmitter types -20C ... + 100C (10 ... 210F), 100 ohm, 3 mA energise Open Collector, 30 V max, 20 mA, 100 mW Frequency 0, 2, 5, 10, 25, 50 Hz @ 50% duty cycle For alarms and telemetry 4-20 mA, loop max. 750 ohm, 26 mA 16 bit max error 0.15% For telemetry and PID control
Direct PRT (4-wire) Input Digital Outputs
Analog Outputs
Analog I/O board
Specification as above except that: 3x 4-20 mA, 100 ohm, 20 bit a/d conversion 1x Hart input instead of 2 Hart input Selectable: either additional 1x 4-20 mA input Selectable: either 1x 4-20 mA output or 1x Digital Output
Communication board
3 Serial Communication ports RS232/ RS485 Galvanically isolated, Port 3: hardware handshake (RTS/CTS); Port 4/5 Software handshake Speeds up to 38400 baud RJ45 Connector Fully user configurable Modbus For DCS, Scada, GC, serial printers or RTU 10/100 MHz RJ45 port with indicators IEEE 802.3 Fully use configurable and programmable Applications such as - Modbus master and slave over TCP - Remote diagnostics and configuration - Web Server functions - Network Time Protocol Provides a redundant network Separate fiscal from maintenance data Secure data transfer Encrypting of data Wide area network capabilities - Take over screen of a remote FC - Download parameters to remote FC - Distribute GC data - Take over serial port (e.g. diagnose GC) - Pipeline totalization
1 Ethernet Port
2nd Ethernet Port or GPRS/UMTS modem*
Independent networks and IP ranges Multiple communication boards can be installed
*available 2009
SUMMIT 8800
Ordering options
Summit 8800 # # Up to 6 slots with free choice of: A: Analogue I/O board or H: Hart I/O board E: Communication board: single Ethernet D: Communication board: dual Ethernet (available 2009)
# Representatives
Algeria Argentina Cameroun Canada Chile Colombia Croatia Denmark Ecuador Egypt Finland Gabon Ghana Greece Hong Kong Hungary Indonesia Iran Ireland Israel Ivory Coast Japan Jordan Kuwait Latvia Libya Lithuania Malaysia Mauritius Mexico Morocco New Zealand Peru Portugal Romania Saudi Arabia Senegal Serbia Slovakia Slovenia Sweden Taiwan Thailand Tunisia Turkey Venezuela Vietnam Yugoslavia
Main Office
KROHNE Oil & Gas Minervum 7441 4801 LH Breda The Netherlands Tel.: +31-76.711.2000 Fax.: +31-76.711.2001 [email protected] www.krohne-oilandgas.com
KROHNE Companies
Australia Austria Belgium Brazil China CIS Czech Republic France Great Britain India Iran Italy Korea Malaysia Netherlands Nigeria Norway Poland Singapore South Africa Switzerland Spain Turkey Ukraine United Arab Emirates USA
KROHNE 09/2008 Subject to change without notice