Vacuum Contactors
Bulletin 1102C Vacuum Contactors
Bulletin 1100 Vacuum Contactors
Page 1-17
Web/CD
Web/CD
Page 1-20
Page 1-20
Page 1-24
Page 1-25
Page 1-28
Page 1-29
Page 1-30
Page 1-31
Page 1-33
Page 1-36
Page 1-37
Page 1-39
Page 1-40
1-1
Table_of_Contents_Tab01.qxd
05/02/2004
09:32
Page 1-2
Page 1-50
Page 1-51
Page 1-52
Page 1-53
Page 1-54
Page 1-55
Page 1-56
Page 1-58
Page 1-60
Page 1-61
Page 1-64
Page 1-65
Page 1-69
Page 1-73
Page 1-74
Page 1-76
1-2
Page 1-77
Page 1-78
Page 1-79
Page 1-80
Page 1-81
Page 1-82
Table_of_Contents_Tab01.qxd
05/02/2004
09:32
Page 1-3
Page 1-83
Page 1-84
Page 1-85
Page 1-86
Page 1-87
Page 1-107
Page 1-113
Page 1-137
Page 1-140
Page 1-142
Page 1-148
Web/CD
NOTE: Information for this product line is available on the Industrial Controls
Catalog CD-ROM (pub. no. A115-CA002A-EN-C) or on the Industrial Controls
Catalog web site www.ab.com/catalogs.
Page 1-149
Page 1-149
Page 1-149
Page 1-152
Page 1-179
Page 1-182
Page 1-185
1-3
Table_of_Contents_Tab01.qxd
05/02/2004
09:32
Page 1-4
Disconnect Switches
Bulletin 1494V Variable-Depth Flange-Mounted
Disconnect Switches
Page 1-190
Page 1-193
Page 1-195
Web/CD
Page 1-199
Page 1-201
Operating Mechanisms
Bulletin 1494V Variable-Depth Flange-Mounted
Remote or Dual Type Operating Mechanisms
Page 1-202
Page 1-203
Page 1-204
Page 1-208
Page 1-210
Fuse Blocks
Bulletin 1491 Fuse Blocks
Web/CD
1-4
Bulletin_400.qxd
05/02/2004
09:42
Page 1-5
Bulletin 400
Table of Contents
Accessories . . . . . . . . . 1-11
Specifications . . . . . . . 1-12
Approximate
Dimensions . . . . . . . . . 1-13
2 Pole
4 Pole
Standards Compliance
y UL 508
y UL Recognized (File No.
E3125, Guide No. NLDX2)
y CSA C22.2 No. 14
Certifications
y CSA Certified File No.
LR1234
y EN/IEC 60947-4-1
y CE Marked
y SEMKO Certified
Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required.
400 DP40 N
a
a
Code
DP25
DP30
DP40
DP50
DP60
DP75
DP90
Current Size
Size
25 A
30 A
40 A
50 A
60 A
75 A
90 A
c
Code
J
D
A
F
B
d
Code
1
2
3
4
b
Suffix Code
N
Number of Poles
Description
1-Pole
(Not available on 40 A)
2-Poles
(Not available on 40 A)
3-Poles
4-Poles
(Only available on 25 A)
Enclosure Code
Enclosure
No Enclosure/No exceptions
Code
B
D
E
K
P
R
S
T
U
Modifications
Description
Box Lug With DP25 or DP30 in 2nd
Position.
400-DRA Factory Attached to DP
(2540A)
2-Poles With 3-Pole Base
6-32 Screw Coil Terminal with DP25,
DP30 or DP40 in 2nd Position
International Packaging
Ring
Terminal
For DP40
To DP90
10-32 SEMS Terminal
Coil Terminals Down
Coil Terminals
On Load Side (T1/2, T2/4, T3/6)
W/O Quick Connect
Line/Load Terminals
W/O Quick Connect
Terminals on Line and Load
1-5
Bulletin_400.qxd
05/02/2004
09:43
Page 1-6
Bulletin 400
Contactors
Number of Poles
FLA Rating
Arc
Cover
1&2
2530
Optional
1-7
Standard
1-8
25
Standard
1-10
50 & 60
Standard
Box Lug
Option available to
accept ring terminals
1-9
Termination
Certifications
Page
Number
2530
40
75 & 90
1-6
Standard
Bulletin_400.qxd
05/02/2004
09:43
Page 1-7
Bulletin 400
Number of Poles
25
25
30
30
Line Voltage
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
Locked Rotor
Amps
150
50
40
150
125
100
150
75
50
150
125
100
Resistive Amps
Rating
30
30
30
35
35
35
40
40
40
40
40
40
Maximum Horsepower
Voltage
Single Phase
120
1
240
120
240
120
240
120
240
Cat. No.
400-DP25N1
400-DP25N2
400-DP30N1
400-DP30N2
J
24
D
120
1 Pole Contactors
A
208/240
F
277
B
480
J
24
D
120
2 Pole Contactors
A
208/240
F
277
B
480
24
18
615
22.5
20
7
5.25
16.5
1 Pole Contactors
120
208/240
277
88
177
221
2070
40140
50165
22.5
22.5
22.5
20
20
20
7
7
7
5.25
5.25
5.25
420
1850
2650
480
384
150270
22.5
20
7
5.25
3050
24
18
615
37
35
8
7
11
2 Pole Contactors
120
208/240
277
88
177
221
2070
40140
50165
37
37
37
35
35
35
8
8
8
7
7
7
250
1000
1600
480
384
150270
37
35
8
7
3050
Arc Cover
Description
1-Pole
2-Pole
Cat. No.
400-C1
400-C2
1-7
Bulletin_400.qxd
05/02/2004
09:43
Page 1-8
Bulletin 400
Number of
Poles
25
30
40
Line Voltage
Locked Rotor
Amps
Resistive Amps
Rating
240/277
480
600
150
125
100
35
35
35
240/277
480
600
180
150
120
40
40
40
240/277
480
600
240
200
160
50
50
50
Voltage
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single Phase
Three Phase
7.5
5
10
15
20
10
10
15
20
10
10
20
25
7.5
Cat. No.
400-DP25N3
400-DP30N3
400-DP40N3
J
24
D
120
A
208/240
F
277
B
480
24
18
615
60
53
6.0
5
7
120
88
2070
60
53
6.0
5
180
208/240
177
40140
60
53
6.0
5
720
277
220
65185
60
53
6.0
5
950
480
384
150270
65
53
6.0
5
3100
50
60
50
60
Hz
Hz
Hz
Hz
Auxiliary Contacts
Description
Cat. No.
400-AB1
400-A1
400-A2
1 NO/1 NC w/QCS
SPDT w/QCs
2 SPDT w/QCs
To use ring terminals on 40 FLA and larger power connections add the suffix R to the catalog number. Example: Cat. No. 400-DP40N3 becomes Cat. No.
400-DP40N3-R.
Contact rating single circuit NO or NC:
Voltage Rating
Break
Make
Amperes
Continuous
120
3.0
30
10
240
1.5
15
10
480
0.75
7.5
10
600
0.6
6
10
1-8
Bulletin_400.qxd
05/02/2004
09:43
Page 1-9
Bulletin 400
75 FLA 3 Pole
No. of Poles
Line Voltage
Locked Rotor
Amps
50
240
480
600
300
250
200
65
65
65
240
480
600
360
300
240
75
75
75
240
480
600
450
375
300
93
93
93
240
480
600
540
450
360
120
120
120
60
75
90
Resistive Amps
Rating
Voltage
110/120
200/208
220240
480
600
110/120
200/208
220240
480
600
110/120
200/208
240
480
600
110/120
200/208
240
480
600
Maximum Horsepower
Single Phase
Three Phase
3
7.5
10
15
15
25
25
5
7.5
10
25
25
30
30
5
10
15
20
25
40
40
7.5
15
20
25
30
50
50
Cat. No.
400-DP50N3
400-DP60N3
400-DP75N3
400-DP90N3
Voltage Code
Nominal Coil Voltage
D
120
A
208/240
F
277
B
480
208/240
50 & 60
75 & 90
Amp
Amp
177
177
40135 40110
140
285
132
240
20
42
14
27
180
63.5
277
50 & 60
75 & 90
Amp
Amp
235
220
50180 65185
140
285
132
240
20
42
14
27
280
84
480
50 & 60
75 & 90
Amp
Amp
374
384
120286 150270
140
285
132
240
20
42
14
27
852
255
24
50
60
50
60
Hz
Hz
Hz
Hz
50 & 60
Amp
18
615
140
132
20
14
2.4
120
75 & 90
Amp
18
615
285
240
42
27
0.63
50 & 60
Amp
93
2070
140
132
20
14
45
75 & 90
Amp
88
2070
285
240
42
27
15.6
Auxiliary Contacts
Description
Cat. No.
400-AB
400-A
1 NO/1 NC w/QCs
SPDT w/QCs
To use ring terminals on 40 FLA and larger power connections add the suffix R to the catalog number. Example: Cat. No. 400-DP60N3 becomes Cat. No.
400-DP60N3-R.
Contact rating single circuit NO or NC:
Voltage Rating
Break
Make
Amperes
Continuous
120
3.0
30
10
240
1.5
15
10
480
0.75
7.5
10
600
0.6
6
10
1-9
Bulletin_400.qxd
05/02/2004
09:43
Page 1-10
Bulletin 400
4 Pole
Number of
Poles
25
Line Voltage
Locked Rotor
Amps
Resistive Amps
Rating
240/277
480
600
150
125
100
35
35
35
Voltage
110/120
200/208
240/277
480
Maximum Horsepower
Single Phase
Three Phase
7.5
5
10
15
Cat. No.
400-DP25N4
J
24
D
120
A
208/240
F
277
B
480
24
19.2
615
68
60
14
9
5
120
93
2070
68
60
14
9
148
208/240
177
40140
68
60
14
9.5
520
277
220
50185
58
52
11
9.5
750
480
384
150270
48
52
11
9
2700
50
60
50
60
Hz
Hz
Hz
Hz
Auxiliary Contacts
Description
Cat. No.
400-AB4
400-A4
1 NO/1 NC w/QCs
SPDT w/QCs
Contact rating single circuit NO or NC:
Voltage Rating
Break
Make
Amperes
Continuous
120
3.0
30
10
240
1.5
15
10
480
0.75
7.5
10
600
0.6
6
10
1-10
Bulletin_400.qxd
05/02/2004
09:43
Page 1-11
Bulletin 400
DP Accessories
Description
Cat. No.
2550 A
1-4-pole
598-BA755Z
2540 A
3-pole
400-MK1
2540 A
1-4-pole
400-DRA
1-11
Bulletin_400.qxd
05/02/2004
09:43
Page 1-12
Bulletin 400
Box Lug
14 1/0 Cu/Al
500 000 operations
100 000 operations
50 lbin.
Dual 0.250 QC
#6 32 screw & 0.250 QC (2)
Standard
130 C Class B
-40 C65 C (-40 F150 F)
All Positions
Base Down Only
4 lbs
25 FLA 4 Pole
Line and Load Terminals
#10 32
Screw
Box Lug
Mechanical Life
Electical Life
Recommended
Tightening
Torque
#10 32
screw
Box Lug
Power
Quick Connects Terminals
Coil Terminals
ARC Cover
Insulation System
Temperature Range
Vertical
Mounting
Position
Horizontal
Weight
#10
32 screw
Box Lug
Mechanical Life
Electrical Life
14 4 Cu/Al
1 000 000 operations
250 000 operations
#10 32
screw
Box Lug
Power
Terminals
Quick Connects
Coil
Terminals
Arc Cover
Insulation System
Temperature Range
Vertical
Mounting
Position
Horizontal
Weight
Recommended
Tightening
Torque
25 lbin.
40 lbin.
Dual 0.250 QC (2)
Quad 0.250 QC
Standard
130 C Class B
-40 C65 C (-40 F150 F
All Positions
Base Down Only
1 lb
1-12
Box Lug
14 2 Cu/Al
500 000 operations
250 000 operations
50 lbin.
Dual 0.250 QC (2)
#6 32 screw & 0.250 QC (2)
Standard
130 C Class B
-40 C65 C (-40 F150 F)
All Positions
Base Down Only
2 lbs
#10 32 screw
16 8
(stranding must be split for #8 wire)
14 4 Cu/Al
1 000 000 operations
250 000 operations
25 lbin.
40 lbin.
Dual 0.250 QC
Dual 0.250 QC (2)
Standard
130 C Class B
-40 C65 C (-40 F150 F)
All Positions
Base Down Only
1.5 lbs
Bulletin_400.qxd
05/02/2004
09:43
Page 1-13
Bulletin 400
1-13
Bulletin_400.qxd
05/02/2004
09:43
Page 1-14
Bulletin 400
1-14
Bulletin_400.qxd
05/02/2004
09:43
Page 1-15
Bulletin 400
Terminations:
#10 32 Combination
Phillips, Slotted &
5/16 Hex Head
#12 washer
40 FLA Lug
14 - 4 Cu/Al
AWG
1-15
Bulletin_400.qxd
05/02/2004
09:43
Page 1-16
Bulletin 400
1-16
Bulletin_1102C.qxd
05/02/2004
09:46
Page 1-17
Bulletin 1102C
Vacuum Contactors
Product Overview/Product Selection
Bulletin 1102C
Table of Contents
y 1500V AC Maximum
y Typical Industry Applications Include:
Mining and Metals
Process Equipment
Chemical Processing
Conveyors
Pumps
Petroleum
Hoists
Mining Equipment
Standards Compliance
Bulletin 1102C open type contactor is designed for use up to 1500V maximum.
Vacuum contactors are particularly well-suited in mining, pumping, and other
applications where voltages above 600V are used.
Bulletin 1102C Line utilizes vacuum bottles to enclose the power switching contacts
within the contactor. The use of vacuum technology results in particularly effective arc
extinguishing above the 600V level and allows the design of a very compact, long
lasting contactor.
UL 508
CSA 22.2 No. 14
EN60947-4 (1000V)
Your order must include: 1) Cat. No. of vacuum contactor, 2) if required, Cat. No. of any accessories.
Product Selection
3, 1500V Maximum, 60 Hz
240V
54
124
248
200V
Hp
kW
50
37
150 120
175 150
380V /
400V
Hp
kW
100
75
270 200
350 300
1500V
390
780
1560
240V
55
110
220
Transformer Primary
Switching kVA
440V
575V
1000V
152
207
346
304
414
692
450
620
1384
1500V
519
1038
2076
Continuous
Current
Cat. No.
Rating (A)
1102C-BO93
200
1102C-CO93
400
1102C-DO93
600
1100V
Hp
kW
375 280
700 520
1000 750
1500V
Hp
kW
Cat. No.
500 370 1102C-BO93
850 650 1102C-CO93
1200 900 1102C-DO93
415V /
440V
Hp
kW
125
95
300 220
400 330
460V
Hp
kW
150 110
325 240
500 350
500V
Hp
kW
190 140
350 260
550 420
575V
Hp
kW
200 153
400 300
600 470
690V
Hp
kW
250 185
500 370
750 550
800V
Hp
kW
300 200
600 475
800 650
Control Voltage
50/60 Hz
120V
D
125V
240V
A
250V
380415V
N
440480V
B
Inrush current should be less than 1000% of IEC AC3 operational current.
For use on transformers having an inrush not more than 20 times the rated full load current irrespective of secondary load. Ratings do not apply to
transformers used in resistive welder service.
Terminal lugs not included see Accessories.
1-17
Bulletin_1102C.qxd
05/02/2004
09:47
Page 1-18
Bulletin 1102C
Vacuum Contactors
Accessories/Contact Arrangements/Contact Ratings
Accessories
Auxiliary Contacts
Contactors are supplied with one normally open and one normally closed auxiliary contacts (A600 rating) as standard. Additional auxiliary
contacts, two normally open and two normally closed, can be added in the field.
Auxiliary Contact (10A @ 600V)
Cat. No. 1195C-N3
Auxiliary Contact (10mA @ 5V DC)
Cat. No. 1195C-N4
Wire Size
2/0250 MCM
(2) #6300 MCM
(2) #2600 MCM
Cat. No.
1195C-LK1
1195C-LK2
1195C-LK3
Contact Arrangements
Specifications
Power Ratings
Insul. & Operating Voltage
Rated Fequency
Making Current Capacity
Breaking Current Capciaty
Dielectric Strength
Interrupting Current (Max)
Mechanical Life
Elect. Life AC3 Duty
Switching Frequency (Mechanical)
for 3s
Withstand current for
short time
for 50 ms
Chop Current Max.
kA
kA
200A
200-1500V
50 - 400 Hz
1600 Amps
1600 Amps
6Kv - 1 Min. Interrupter GAP
2.2 kA
Consult Factory
500000
1000/HR
3.2
10
0.9 A
Control Ratings
400A
200-1500V
50 - 400 Hz
3200 Amps
3200 Amps
6Kv - 1 Min. Interrupter GAP
4.6 kA
Consult Factory
500000
1000/HR
6.0
18
0.9 A
600A
200-1500V
50 - 400 Hz
4800 Amps
4800 Amps
6Kv - 1 Min. Interrupter GAP
6 kA
Consult Factory
250000
1000/HR
6.5
30
0.9 A
-15% +10%
-15% +10%
800 VA
450 VA
12 VA
18 VA
150165
95150
1318
3040
80% Cold 85% Hot
80% Cold 85% Hot
50% or less
50% or less
Application Ratings
-15% +10%
450 VA
26 VA
120195
3040
80% Cold 85% Hot
50% or less
Mounting Installation
Altitude
Ambient Storage
Operating Temperature
Vibration/Shock
Weight
All Planes
6600 ft. 2000 Meters
-65 F (-54 C) +160 F (71 C)
-40 F (-40 C) +135 F (57 C)
40Hz-2G/50G
12lbs./5.5kg.
All Planes
6600 ft. 2000 Meters
-65 F (-54 C) +160 F (71 C)
-40 F (-40 C) +135 F (57 C)
40Hz-2G/50G
28lbs./12.7kg.
1-18
All Planes
6600 ft. 2000 Meters
-65 F (-54 C) +160 F (71 C)
-40 F (-40 C) +135 F (57 C)
40Hz-2G/50G
26lbs./11.8kg.
Bulletin_1102C.qxd
05/02/2004
09:47
Page 1-19
Bulletin 1102C
Vacuum Contactors
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
1-19
Bulletin_500.qxd
05/02/2004
09:54
Page 1-20
Bulletin 500
NEMA AC Contactors
Top Wiring for Motor Loads
Bulletin 500
Table of Contents
y Top wiring
y For motor loads
y Enclosure ratings: NEMA Type 1, 3R/12, 4/4X (S.S.), glass reinforced
polyester and bolted 7 & 9, and 3R, 7 & 9
Bulletin 500 AC Contactors are available in Top Wiring Construction
from NEMA Size 009. All power connections are at the top of the
contactors. Bulletin 500 contactors are used for switching AC motor
loads where overload protection is not required or is provided
separately.
Standards Compliance
and Certifications
See Below
Size 0, 3-Pole,
Open Type without Enclosure
Top Wiring Construction
500 B A D 930 1
a
500
500F
500FL
500L
505
509
520
Description
Combination Top wired for motor
loads
Contactor Feed-through wiring
contactor for motor loads
Contactor Feed-through lighting
contactor, 3 pole maximum
Contactor Top wired lighting
contactor
Starter Reversing
Starter Non-reversing
Starter Multispeed
b
NEMA Size
Suffix
Code
A
B
C
D
E
F
G
H
J
K
T
Bulletin No.
Bulletin
No.
Description
0
1
2
3
4
5
6
7
8
9
00
Code
A
C
E
H
J
O
S
d
Nominal Coil Voltage
FreqFreqCode Voltage
Code Voltage
uency
uency
230
380
A
KN
60 Hz
50 Hz
240V
400V
460
B
M
500V
50 Hz
60 Hz
480V
575
C
N
380V
50 Hz
60 Hz
600V
115
220
D
P
60 Hz
50 Hz
120V
230V
440
F
277V
60 Hz
Q
50 Hz
460V
200
H
R
550V
50 Hz
60 Hz
208V
110
I
415V
50 Hz
S
50 Hz
115V
J
24V
60 Hz
T
240V
50 Hz
K
24V
50 Hz
U
415V
60 Hz
e
Number of Poles
Applies to Contactors Only
Code
Voltage Description
92
Two Poles
920 Two Poles and (1) Auxiliary Contact (N.O.)
93
Three poles
Three Poles and (1) Auxiliary Contact
930
(N.O.)
94
Four Poles
Four Poles and (1) Auxiliary Contact
940
(N.O.)
95
Five Poles
950 Five Poles and (1) Auxiliary Contact (N.O.)
Note: All enclosed non-combination contactors and starters are supplied with external reset as standard.
1-20
f
Options
See catalog for detailed
information on options.
Bulletin_500.qxd
05/02/2004
09:54
Page 1-21
Bulletin 500
NEMA AC Contactors
Product Selection
NEMA
Size
Continuous
Ampere
Rating (A)
Without Auxiliary
Contact
Type 1
General Purpose
Enclosure
Type 3R/12
Rainproof,
Dusttight
Industrial Use
Enclosure
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
500-TA920
500-AA920
500-BA920
500-CA920
500-DA920
500-EA920
500-FA920
500-HA920
500-JA920
500-KA920
500-AJ920
500-BJ920
500-CJ920
500-DJ920
500-EJ920
500-FJ920
500-HJ920
500-AC920
500-BC920
500-CC920
500-DC920
500-EC920
500-FC920
500-HC920
Motor Voltage
115V
230V
9
18
27
45
90
135
270
540
810
1215
2250
1/3
1
2
3
7-1/2
1
2
3
7-1/2
15
500-TO92
500-AO92
500-BO92
500-TO920
500-AO920
500-BO920
500-CO920
500-DO920
500-EO920
500-FO920
500-HO920
500-JO920
500-KO920
NEMA
Size
00
0
1
2
3
4
5
6
7
8
9
Continuous
Ampere
Rating (A)
9
18
27
45
90
135
270
540
810
1215
2250
200V
1-1/2
3
7-1/2
10
25
40
75
150
230V
1-1/2
3
7-1/2
15
30
50
100
200
300
450
800
380
415V
2
5
10
25
50
75
150
300
600
900
1600
460
575V
2
5
10
25
50
100
200
400
600
900
1600
500-TO93
500-AO93
500-BO93
500-TA93011
500-AA93011
500-BA93011
500-CA930
500-DA930
500-EA930
500-FA930
500-GA930
500-HA930
500-JA930
500-KA930
500-TO930
500-AO930
500-BO930
500-CO930
500-DO930
500-EO930
500-FO930
500-GO930
500-HO930
500-JO930
500-KO930
500-AJ93011 500-AC93011
500-BJ93011 500-BC93011
500-CJ930
500-CC930
500-DJ930
500-DC930
500-EJ930
500-EC930
500-FJ930
500-FC930
500-GJ930 500-GC930
500-HJ930
500-HC930
24V
110115V
115120V
200208V
220230V
50 Hz
60 Hz
Sa
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
Fiberglass-reinforced polyester hubs are included with each starter at no additional charge.
On Size 7 and larger, the auxiliary contact is located on the interposing relay.
Does not include line and load lugs, see page 1-95 for kits.
Size 6 has feed through wiring.
Price includes control circuit transformer.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
a This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
7 This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
11These devices may be ordered without an auxiliary.
1-21
Bulletin_500.qxd
05/02/2004
09:54
Page 1-22
Bulletin 500
NEMA AC Contactors
Product Selection, Continued
Top Wiring For Motor Loads, Continued
Open Type Without Enclosure
Maximum Horsepower
Rating
Full Load Current Must Not
Exceed
Continuous Ampere Rating
Motor Voltage
50 Hz
NEMA
Size
Continuous
Ampere
Rating (A)
200V
380
415V
230V
Without Auxiliary
Contact
Type 1
General
Purpose
Enclosure
Cat. No.
Cat. No.
Cat. No.
460
575V
Type 3R/12
Rainproof,
Dusttight
Industrial
Use
Enclosure
Type 4/4X
Watertight,
CorrosionResistant
Enclosures
Stainless Steel
Cat. No.
Cat. No.
9
18
27
45
90
135
270
1-1/2
3
7-1/2
10
25
40
75
1-1/2
3
7-1/2
15
30
50
100
2
5
10
25
50
75
150
2
5
10
25
50
100
200
500-TO94
500-AO94
500-BO94
500-AO940
500-BO940
500-CO940
500-DO940
500-EO940
500-FO940
500-AA940
500-BA940
500-CA940
500-DA940
500-EA940
500-FA940
500-AJ940
500-BJ940
500-CJ940
500-DJ940
500-EJ940
500-FJ940
500-AC940
500-BC940
500-CC940
500-DC940
500-EC940
500-FC940
500-AO950
500-BO950
500-CO950
500-DO950
500-AA950
500-BA950
500-CA950
500-DA950
500-AJ950
500-BJ950
500-CJ950
500-DJ950
500-AC950
500-BC950
500-CC950
500-DC950
500-EO950
500-EA950 500-EJ950
500-EC950
NEMA
Size
0
1
2
3
4
Continuous
Ampere
Rating (A)
18
27
45
90
135
200V
3
7-1/2
10
25
40
380
415V
230V
3
7-1/2
15
30
50
5
10
25
50
75
460
575V
5
10
25
50
100
500-AO95
500-BO95
200208V
220230V
Pa
Voltage
24V
110115V
50 Hz
60 Hz
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
On Size 7 and larger, the auxiliary contact is located on the control relay.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
a This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-22
Bulletin_500.qxd
05/02/2004
09:54
Page 1-23
Bulletin 500
NEMA AC Contactors
Product Selection, Continued
Top Wiring for Motor Loads, Continued
Special Purpose Enclosures
Description
Contactor
Size
0
1
2
3
4
5
Poles
13
45
13
45
13
13
13
13
Type 4X
Watertight CorrosionResistant Enclosure
Fiberglass-Reinforced
Polyester
A
A
A
A
NA
NA
NA
NA
1-23
Bulletin_500F.qxd
05/02/2004
10:17
Page 1-24
Bulletin 500F
NEMA AC Contactors
Feed-Through Wiring for Motor Loads
Bulletin 500F
Table of Contents
y Feed-Through Wiring
y For Motor Loads
Description
The Bulletin 500F AC Contactor (Open Type) is available in FeedThrough Wiring Construction from NEMA Size 05. Feed-Through
Contactors have the line terminals at the top of the device and load
terminals at the bottom. Bulletin 500F contactors are used for
switching AC motor loads where overload protection is not required or
is provided separately. The contactors may be operated remotely by
pilot devices, such as push buttons, selector switches, timers, relays
or temperature switches.
Accessories . . . . . . . . . 1-93
Modifications . . . . . . . 1-87
Specifications . . . . . . . 1-107
Full Load Currents
of AC Motors . . . . . . . 1-112
Approximate
Dimensions . . . . . . . . . 1-113
Coil Data . . . . . . . . . . . 1-110
Standards Compliance
and Certifications
See Below
Size 1, 3-Pole
Open Type without Enclosure
Feed Through Construction
with Auxiliary Contact
Continuous
NEMA Ampere Rating
Size
(A)
0
18
1
27
2
45
3
90
4
135
5
270
115V
230V
1
1
2
3
7-1/2
Cat. No.
500F-AO92
500F-BO92
2
3
7-1/2
15
Cat. No.
500F-AO920
500F-BO920
500F-CO920
500F-DO920
500F-EO920
500F-FO920
200V
230V
3
7-1/2
10
25
40
75
3
7-1/2
15
30
50
100
380415V
460575V
5
10
25
50
75
150
5
10
25
50
100
200
3
500F-AO93
500F-BO93
500F-AO930
500F-BO930
500F-CO930
500F-DO930
500F-EO930
500F-FO930
24V
K
J
110115V
S
115120V
200208V
220230V
P
230240V
240V
T
277V
380V
N
380400V
KN
415V
I
U
440460V
Q
460480V
500V
M
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on page 1-129.
This
This
This
This
coil
coil
coil
coil
1-24
is
is
is
is
optimized
optimized
optimized
optimized
for
for
for
for
110115V,
115120V,
220230V,
230240V,
50
60
50
60
Hz
Hz
Hz
Hz
applications,
applications,
applications,
applications,
but
but
but
but
can
can
can
can
be
be
be
be
used
used
used
used
at
at
at
at
120V,
110V,
240V,
220V,
60
50
60
50
Hz
Hz
Hz
Hz
nominal.
nominal.
nominal.
nominal.
550V
R
575600V
Bulletin_500L.qxd
05/02/2004
10:22
Page 1-25
Bulletin 500L
NEMA AC Contactors
Top Wiring for Non-Motor and Lighting Loads
Bulletin 500L
Table of Contents
y Top Wiring
y For Non-Motor Loads
Lighting
Heating
y NEMA Sizes to 2250 A
y Enclosure Ratings: NEMA Type 1, 3R/12, 4/4X (Stainless Steel)
y Special Purpose Enclosures
Type 4X Glass Reinforced Polyester
Bolted 7 & 9, and 3R, 7 & 9
y 2-, 3-, and 4-Pole Configurations
Description
100 A, 3-Pole
Open Type without
Enclosure
Bulletin 500L lighting contactors are electrically held contactors designed to switch the
current to incandescent filament, fluorescent, mercury arc lamps, capacitors and other
non-motor loads. These contactors are not suitable for use on sign flashers.
HOLD-IN CONTACT If a hold-in contact for 3-wire push button control is required,
it must be specified on the order as a modification. A normally open auxiliary contact
to be used as a hold-in contact can also be added in the field. See page 1-87 for
information.
Standards Compliance
and Certifications
See Below
Your order must include 1) Cat. No. of contactor selected, 2) modifications, if any, and 3) for motor loads, use Bulletin 500 contactors listed
on page 1-21.
1-25
Bulletin_500L.qxd
05/02/2004
10:22
Page 1-26
Bulletin 500L
NEMA AC Contactors
Product Selection
Tungsten Lamp
Loads
(Maximum
480V Line
277V Load)
Open Type
Without Enclosure
Type 1
General Purpose
Enclosure
Type 4/4X
Watertight, CorrosionResistant Enclosure
Stainless Steel
Type 3R/12
Rainproof, Dusttight
Industrial Use Enclosure
Cat. No.
Cat. No.
Cat. No.
Cat. No.
500L-AC92
500L-BC92
500L-CC92
500L-DC92
500L-EC92
500L-FC92
500L-HC92
500L-AJ92
500L-BJ92
500L-CJ92
500L-DJ92
500L-EJ92
500L-FJ92
500L-HJ92
Cat. No.
500L-AC93
500L-BC93
500L-CC93
500L-DC93
500L-EC93
500L-FC93
500L-GC93
500L-HC93
Cat. No.
500L-AJ93
500L-BJ93
500L-CJ93
500L-DJ93
500L-EJ93
500L-FJ93
500L-GJ93
500L-HJ93
500L-TO92
500L-AO92
500L-BO92
500L-CO92
500L-DO92
500L-EO92
500L-FO92
500L-HO92
500L-JO92
500L-KO92
10
20
30
60
100
200
300
540
810
1215
2250
500L-TA92
500L-AA92
500L-BA92
500L-CA92
500L-DA92
500L-EA92
500L-FA92
500L-HA92
500L-JA92
500L-KA92
5
15
30
60
100
200
300
540
810
1215
2250
Cat. No.
500L-TO93
500L-AO93
500L-BO93
500L-CO93
500L-DO93
500L-EO93
500L-FO93
500L-GO93
500L-HO93
500L-JO93
500L-KO93
10
20
30
60
100
200
300
540
810
1215
2250
Cat. No.
500L-TA93
500L-AA93
500L-BA93
500L-CA93
500L-DA93
500L-EA93
500L-FA93
500L-GA93
500L-HA93
500L-JA93
500L-KA93
24V
110115V
115120V
200208V
220230V
50 Hz
60 Hz
Da
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
Does not include line and load lugs, see page 1-95 for kits.
Feed through wiring only.
Price includes control circuit transformers.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on page 1-129.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
a This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-26
Bulletin_500L.qxd
05/02/2004
10:22
Page 1-27
Bulletin 500L
NEMA AC Contactors
Product Selection, Continued
Top Wiring for Non-Motor and Lighting Loads, Continued
Maximum Continuous
Ampere Ratings (A)
General Use
Resistive Heating
Tungsten Lamp
Ballast Lighting
Loads
(Fluorescent)
(Maximum
Discharge Lighting
480V Line
(Mercury Vapor High
277V Load)
Pressure Sodium
and Metal Halide)
Open Type
Without Enclosure
Type 1
General Purpose
Enclosure
Type 4/4X
Watertight, CorrosionResistant Enclosure
Stainless Steel
Type 3R/12
Rainproof, Dusttight
Industrial Use Enclosure
Cat. No.
Cat. No.
Cat. No.
Cat. No.
500L-AC94
500L-BC94
500L-CC94
500L-DC94
500L-EC94
500L-FC94
500L-AJ94
500L-BJ94
500L-CJ94
500L-DJ94
500L-EJ94
500L-FJ94
500L-TO94
500L-AO94
500L-BO94
500L-CO94
500L-DO94
500L-EO94
500L-FO94
10
20
30
60
100
200
300
500L-TA94
500L-AA94
500L-BA94
500L-CA94
500L-DA94
500L-EA94
500L-FA94
24V
K
110115V
S
115120V
200208V
220230V
P
230240V
240V
T
277V
380V
N
380400V
KN
415V
I
440460V
Q
460480V
500V
M
550V
R
575600V
60 Hz
Size
0
1
2
3
4
5
Type 4X
Watertight,CorrosionResistant
Enclosure FiberglassReinforced
Polyester
A
A
A
A
NA
NA
NA
NA
Poles
13
45
13
45
13
13
13
13
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on page 1-129.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-27
Bulletin_500FL.qxd
05/02/2004
10:25
Page 1-28
Bulletin 500FL
NEMA AC Contactors
Feed-Through Wiring for Non-Motor and Lighting Loads Product Selection
Bulletin 500FL
Table of Contents
y Feed-Through Wiring
y For Non-Motor Loads
Lighting
Heating
y NEMA Sizes to 300 A
y 2- and 3-Pole Configurations
Description
30 A
Open Type
without Enclosure
100 A
Open Type
without Enclosure
Accessories . . . . . . . . . 1-93
Modifications . . . . . . . 1-87
Specifications . . . . . . . 1-107
Full Load Currents
of AC Motors . . . . . . . 1-112
Approximate
Dimensions . . . . . . . . . 1-113
Coil Data . . . . . . . . . . . 1-110
Standards Compliance
and Certifications
See Below
Your order must include 1) Cat. No. of contactor selected, 2) modifications, if any, and 3) for motor loads, use Bulletin 500F contactors listed
on page 1-24.
Cat. No.
500FL-AO92
500FL-BO92
500FL-CO92
500FL-DO92
500FL-EO92
500FL-FO92
Maximum Continuous
Ampere Ratings (A)
Non-Motor Loads
General Use
Resistive Heating
Ballast Lighting
(Fluorescent)
Tungsten Lamp Loads
Discharge Lighting
(Maximum
(Mercury Vapor High Pressure
480V Line
Sodium, and Metal Halide)
277V Load)
15
20
30
30
60
60
100
100
200
200
300
300
Open Type
without
Enclosure
Cat. No.
500FL-AO93
500FL-BO93
500FL-CO93
500FL-DO93
500FL-EO93
500FL-FO93
24V
K
J
110115V
S
115120V
200208V
220230V
P
230240V
240V
T
277V
380V
N
380400V
KN
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-28
415V
I
U
440460V
Q
460480V
500V
M
550V
R
575600V
Bulletin_500LP.qxd
05/02/2004
10:29
Page 1-29
Bulletin 500LP
NEMA AC Contactors
Top Wiring Permanent Magnet Latching for Non-Motor and Lighting Loads
Bulletin 500LP
Table of Contents
Accessories . . . . . . . . . 1-93
Modifications . . . . . . . 1-87
Specifications . . . . . . . 1-107
Full Load Currents
of AC Motors . . . . . . . 1-112
Approximate
Dimensions . . . . . . . . . 1-113
Description
Bulletin 500LP open type contactors are permanent magnet latching
type contactors designed to switch the current to incandescent
filament, fluorescent, mercury arc lamps, capacitors and other nonmotor loads.
Standards Compliance
y NEMA/EEMAC ICS 2
y UL 508
y CSA C22.2 No. 14
Certifications
30 A, 3-Pole
Open Type without Enclosure
Your order must include 1) Cat. No. of contactor selected and 2) modifications, if any.
Note: For motor load application, order a Bulletin 500PM. For
Bulletin 500PM information, consult your local Allen-Bradley
distributor.
Maximum Continuous
Ampere Ratings (A)
General Use
Resistive Heating
Tungsten Lamp
Ballast Lighting
Loads
(Fluorescent)
(Maximum 480V
Discharge Lighting
Line 277V Load)
(Mercury Vapor High
Pressure Sodium, and
Metal Halide)
15
30
60
100
200
300
Open Type
Without
Enclosure
Type 1 General
Purpose
Enclosure
Cat. No.
Cat. No.
380V
110115V
S
380400V
KN
Voltage
50 Hz
60 Hz
24V
K
J
Voltage
50 Hz
60 Hz
115120V
220230V
P
460480V
230240V
240V
T
415V
200208V
H
440460V
500V
550V
277V
F
575600V
I
U
15
30
60
100
200
300
20
30
60
100
200
300
500LP-AO93
500LP-BO93
500LP-CO93
500LP-DO93
500LP-EO93
500LP-FO93
500LP-AA93
500LP-BA93
500LP-CA93
500LP-DA93
500LP-EA93
500LP-FA93
15
30
60
100
200
300
20
30
60
100
200
300
500LP-AO94
500LP-BO94
500LP-CO94
500LP-DO94
500LP-EO94
500LP-AA94
500LP-BA94
500LP-CA94
500LP-DA94
500LP-EA94
1-29
Bulletin_505.qxd
05/02/2004
10:34
Page 1-30
Bulletin 505
Table of Contents
Description
Bulletin 505 reversing starters are most commonly used for full voltage starting and reversing of polyphase squirrel cage motors. Starters Size
00 through 9 are electrically and mechanically interlocked to avoid both contactors being closed simultaneously. Bulletin 505V vertically
arranged starters are available in Sizes 05 in the Open Type without Enclosure construction only. Bulletin 505 reversing starters are
available with Bulletin 592 eutectic alloy overload relays as standard and Bulletin 592 solid-state overloads are optional for additional flexibility
in motor protection.
1-30
Bulletin_505.qxd
05/02/2004
10:34
Page 1-31
Bulletin 505
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. See page 1-152 for heater element selection
tables.
NEMA Size
00
0
1
2
3
4
5
6
7
8
9
Continuous
Ampere
Rating (A)
9
18
27
45
90
135
270
540
810
1215
2250
200V
1-1/2
3
7-1/2
10
25
40
75
150
230V
1-1/2
3
7-1/2
15
30
50
100
200
300
450
800
380415V
2
5
10
25
50
75
150
300
600
900
1600
460575V
2
5
10
25
50
100
200
400
600
900
1600
Cat. No.
505-TO-
505-AO-
505-BO-
505-CO-
505-DO-
505-EO-
505-FO-
505-GO-
505-HO-
505-JO-
505-KO-
Cat. No.
505-TA-
505-AA-
505-BA-
505-CA-
505-DA-
505-EA-
505-FA-
505-GA-
505-HA-
505-JA-
505-KA-
Type
3R/12,
Rainproof,
Dusttight
Industrial
Use
Enclosure
Type 4/4X
Watertight,
CorrosionResistant
Enclosures
Stainless
Steel
Cat. No.
505-AJ-
505-BJ-
505-CJ-
505-DJ-
505-EJ-
505-FJ-
505-GJ-
505-HJ-
505-JJ-
Cat. No.
505-AC-
505-BC-
505-CC-
505-DC-
505-EC-
505-FC-
505-GC-
505-HC-
Type 4X
Watertight,
CorrosionResistant
Enclosure
FiberglassReinforced
Polyester
Cat. No.
505-AS-
505-BS-
505-CS-
110V115V
115120V
200208V
220230V
230240V
50 Hz
60 Hz
P7
50 Hz
60 Hz
Voltage
Common Controla
Separate Control
(without transformer)
380V
380400V
KN
240V
277V
A11
440460V
460480V
415V
550V
575600V
500V
will be the listed Cat. No. with the No. 23 added.Example: Cat. No. 505-AOD- would be Cat. No. 505-AOD-23.
Vertically Arranged Full Voltage Reversing Starters, Sizes 05, Open Type Without Enclosure can be supplied in a vertically arranged construction. To
order, change the bulletin number in the listed Cat. No. from 505 to 505V. Example: Cat. No. 505V-AOD-A2D with solid-state overload relay and Cat. No.
505V-AOD with eutectic alloy overload relay.
Fiberglass reinforced polyester hubs are included with each starter. Sizes 6 through 8 are painted enclosures.
Does not include line and load lugs. See page page 1-95 for kits.
Price includes Control Circuit Transformer. This applies to NEMA size 6 Enclosed, only.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
a When selecting a factory installed control circuit transformer (see Modifications page 1-88), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BAB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BABJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
7 This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
11This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-31
Bulletin_505.qxd
05/02/2004
10:34
Page 1-32
Bulletin 505
NEMA
Size
0
1
2
3
4
Continuous
Ampere
Rating (A)
18
27
45
90
135
230V
3
7-1/2
15
30
50
380415V
5
10
25
50
75
Cat. No.
505-AU-
505-BU-
460575V
5
10
25
50
100
Cat. No.
505-AE-
505-BE-
505-CE-
505-DE-
505-EE-
Cat. No.
505-AH-
505-BH-
505-CH-
505-DH-
505-EH-
110V115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
60 Hz
Da
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
will be the listed Cat. No. with the No. 23 added. Example: Cat. No. 505-AUD- would be Cat. No. 505-AUD-23.
For NEMA Type 3R application it is necessary that a drain or breather and drain be added. See Factory Modifications or Accessories.
Includes drain and cover gasket.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
When selecting a factory installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BUB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BUBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
a This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
7 This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-32
Bulletin_505.qxd
05/02/2004
10:34
Page 1-33
Bulletin 505
NEMA
Size
Continuous
Ampere
No. of
Rating (A) Poles
2
00
9
3
18
3
27
3
Repulsion
Induction
3 Lead Split
505-TO-102 505-TA-102
Phase
1/3
1
Use Size 0 Starter
4 Lead
505-TO-103 505-TA-103
Repulsion
Induction
4 Lead Split
505-TO-104 505-TA-104
Phase
3 Lead
505-AO-101 505-AA-101 505-AJ-101 505-AC-101 505-AE-101
505-AH-101
Repulsion
Induction
3 Lead Split
505-AO-102 505-AA-102 505-AJ-102 505-AC-102 505-AE-102
505-AH-102
Phase
4 Lead
505-AO-103 505-AA-103 505-AJ-103 505-AC-103 505-AE-103
505-AH-103
Repulsion
1
2
Induction
4 Lead Split
505-AO-104 505-AA-104 505-AJ-104 505-AC-104 505-AE-104
505-AH-104
Phase
4 Lead Split
505-AO-105 505-AA-105 505-AJ-105 505-AC-105
Phase
200208V
220230V
230240V
240V
110V115V
XS
115120V
50 Hz
24V
XPa
XT
277V
60 Hz
XD
XH
XA
XF
50 Hz
XWS
XWPa
XWT
60 Hz
XWJ
XWD
XWH
XWA
XWF
Ordering Information All 1 reversing starter orders must be accompanied with a circuit diagram of the motor.
Omission of Overload Relays Bulletin 505 reversing starters are available without overload protection. Cat. Nos. for all starters without overload protection
will be the listed Cat. No. with the No. 23 added. Example: Cat. No. 505-AOXD-101 would be Cat. No. 505-AOXD-23-101.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
When selecting a factory installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BAXA-6P-101 will have a
transformer with a 240V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BAXAJ-6P-101 will have a transformer with a 240V
primary/24V secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
a This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-33
Bulletin_505.qxd
05/02/2004
10:35
Page 1-34
Bulletin 505
Bulletin 505
3 3-Pole
Reversing Starter with Eutectic Alloy Overload Relay
and Solid-State Overload Relays
Bulletin 505
3 3-Pole
Reversing Starter without Overload Relay
Bulletin 505V
3 3-Pole
Vertical Reversing Starter with Eutectic Alloy Overload Relay,
With Solid-State Overload Relays
Separate Control Circuit When the controller coils are to operate on a voltage other than line voltage, check coil rating for compatibility
and change coils if necessary. Disconnect wires A and B from lines L1 and L2. Connect wires A and B to the separate control source. Refer
to local Electrical Code for control circuit disconnection requirements.
1-34
Bulletin_505.qxd
05/02/2004
10:35
Page 1-35
Bulletin 505
Bulletin 505
1 3-Pole (Suffix 104)
Reversing Starter with
Eutectic Alloy Overload Relay
Bulletin 505
1 4-Pole (Suffix 105)
Reversing Starter with
Eutectic Alloy Overload Relay
Bulletin 505
1 2-Pole (Suffix 101 and 102)
Reversing Starter with
Eutectic Alloy Overload Relay
Bulletin 505
1 3-Pole (Suffix 103)
Reversing Starter with
Eutectic Alloy Overload Relay
Separate Control Circuit When the controller coils are to operate on a voltage other than line voltage, check coil rating for compatibility
and change coils if necessary. Disconnect wires A and B from lines L1 and L2. Connect wires A and B to the separate control source. Refer
to local Electrical Code for control circuit disconnection requirements.
1-35
Bulletin_509.qxd
05/02/2004
10:42
Page 1-36
Bulletin 509
Bulletin 509
Table of Contents
Bulletin 509 starters are designed for full voltage starting of polyphase
squirrel cage motors. These starters meet NEMA Standards, are easy
to wire and service, simple to select, and offer a broad range of NEMA
sizes (00 through 9).
These starters may be operated by remote control with push buttons,
float switches, thermostats, pressure switches, snap switches, limit
switches, or any other suitable two or three wire pilot device.
All Bulletin 509 Size 00 through 9 starters are available with Bulletin
592 eutectic alloy overload relays as standard and solid-state
overloads are optional for additional flexibility in motor protection.
Standards and
Certifications
See below.
1-36
Bulletin_509.qxd
05/02/2004
10:42
Page 1-37
Bulletin 509
Heater Elements Starters with eutectic alloy overload relay require 3 heater elements. See page page 1-152 for heater element selection
tables.
NEMA
Size
Continuous
Ampere
Rating (A)
00
0
1
2
3
4
5
6
7
8
9
18
27
45
90
135
270
540
810
1215
2250
509-HO-
509-HA-
509-HJ-
300
600
600
509-JO-
509-JA-
509-JJ-
450
900
900
509-KO-
509-KA-
509-KJ-
800
1600
1600
Type 4X
Watertight
Type 4/4X
Corrosion-Resistant
Watertight
Enclosure
Corrosion-Resistant
FiberglassEnclosures
Reinforced
Polyester
Stainless Steel
Cat. No.
Cat. No.
509-AC-
509-BC-
509-CC-
509-DC-
509-EC-
509-FC-
509-GC-
509-HC-
509-JC-
509-KC-
509-AS-
509-BS-
509-CS-
110115V
115120V
50 Hz
60 Hz
50 Hz
60 Hz
Voltage
Common Control
Separate Control
(without transformer)
200208V
220230V
Sa
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
1-37
Bulletin_509.qxd
05/02/2004
10:42
Page 1-38
Bulletin 509
Unilock Enclosure
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. See page 1-152 for heater element selection
tables.
NEMA
Size
0
1
2
3
4
5
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
Sa
60 Hz
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
Omission of Overload Relays Bulletin 509 full voltage starters are available without overload protection. Cat. Nos. for all starters without overload
protection will be the Cat. No. with the No. 23 added. Example: Cat. No. 509-AUD- would be Cat. No. 509-AUD-23.
Includes drain and cover gasket.
NEMA Size 5 Unilock enclosed starters have a Continuous Ampere Rating of 210 A.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
When selecting a factory-installed control circuit transformer (see Modifications page page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 509-BUB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 509-BUBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
a This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
7 This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-38
Bulletin_509.qxd
05/02/2004
10:42
Page 1-39
Bulletin 509
NEMA
Size
00
0
1
1P
2
3
Continuous
Ampere
Rating (A)
9
18
27
36
45
90
NEMA Size
0
1
1P
2
509-AO-
509-AA-
509-AJ-
1
2
509-BO-
509-BA-
509-BJ-
2
3
509-XO-
509-XA-
509-XJ-
3
5
509-CO-
509-CA-
509-CJ-
3
7-1/2
509-DO-
509-DA-
509-DJ-
7-1/2
15
Continuous
Ampere
Rating (A)
18
27
36
45
Type 4X
Watertight
CorrosionResistant
Enclosure
FiberglassReinforced
Polyester
Cat. No.
509-AS-
509-BS-
509-XS-
509-CS-
Type 4/4X
Watertight,
CorrosionResistant
Enclosure
Stainless Steel
Cat. No.
509-AC-
509-BC-
509-XC-
509-CC-
509-DC-
50 Hz
24V
110115V
XS
115120V
200208V
60 Hz
50 Hz
60 Hz
220230V
XP
230240V
240V
XT
277V
XD
XWS
XH
XF
XWP
XAa
XWT
XWJ
XWD
XWH
XWAa
XWF
1-39
Bulletin_520.qxd
05/02/2004
20:29
Page 1-40
Bulletin 520
Bulletin 520
Table of Contents
y NEMA Sizes 07
y Exceptional Electrical Life
y UL Witnessed Type 2 Coordination
y Dependable Coil Operation
y Eutectic Alloy Overload Relays Class 10, 20, or 30
y Solid-State Overload Relays Class 10, 15, 20, or 30
y Vertically Arranged Bulletin 520V Sizes 05
Bulletin 520F
Size 0, with Eutectic Alloy Overload
Relay
2-Speed, Consequent Pole
Open Type without Enclosure
Bulletin 520 multi-speed starters are designed for the control of two speed squirrel
cage motors of either consequent pole or separate winding types. These starters are
available for constant horsepower, constant torque or variable torque, three-phase
motors. Multi-speed motor starters are commonly used on machine tools, fans,
blowers, refrigeration compressors, and many other types of equipment.
All Bulletin 520 multi-speed starters are available with Bulletin 592 eutectic alloy relays
as standard and solid-state overloads are optional for additional flexibility in motor
protection. Bulletin 520V vertically arranged starters are available in Sizes 05, in the
Open Type without Enclosure construction only.
y Hazardous Location:
UL Listed (File No. E10314)
CSA Certified (LR 11924)
Your order must include: 1) Cat. No. of the starter selected, 2) motor connection diagram, 3) if required, Cat. No. of any accessories, 4)
specify whether motor is Constant Torque, Variable Torque, or Constant Horsepower, 5) heater elements for eutectic alloy overload voltages
are not included and must be ordered as a separate Cat. No. located on page 1-152, and 6) overload relay code for solid-state overload
relays. See page 1-140.
1-40
Bulletin_520.qxd
05/02/2004
20:29
Page 1-41
Bulletin 520
NEMA
Size
0
1
2
3
4
5
6
7
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
540
810
230V
3
7-1/2
15
30
50
100
200
300
380415V
5
10
25
50
75
150
300
600
Cat. No.
520E-AO--
520E-BO--
520E-CO--
520E-DO--
520E-EO--
520E-FO--
520E-GO--
520E-HO--
460575V
5
10
25
50
100
200
400
600
Type 3R/12
Rainproof, Dusttight
Industrial Use
Enclosure
Cat. No.
520E-AA--
520E-BA--
520E-CA--
520E-DA--
520E-EA--
520E-FA--
Cat. No.
520E-AJ--
520E-BJ--
520E-CJ--
520E-DJ--
520E-EJ--
520E-FJ--
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
60 Hz
Da
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page 1-45.
Vertically Arranged Multi-speed starters, sizes 05, Open Type Without Enclosure can be supplied in a vertically arranged construction. To order, change
the Bulletin number in the listed Cat. No. from 520E to 520VE. Example: Cat. No. 520VE-BOD-A2D-A2D.
Does not include line and load lugs, see page 1-95 for kits.
Only available on sizes 005. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA vaules on page 1-129.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520E-BAB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520E-BABJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
a This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-41
Bulletin_520.qxd
05/02/2004
20:29
Page 1-42
Bulletin 520
NEMA
Size
0
1
2
3
4
5
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
520E-FC--
75
100
150
200
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
60 Hz
Da
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, page 1-45.
Fiberglass reinforced polyester hubs are included with each starter.
Includes drain and cover gasket.
When using 24V coils on size 4 or 5, an interposing relay may be required.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520E-BCB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520E-BCBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
a This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-42
Bulletin_520.qxd
05/02/2004
20:29
Page 1-43
Bulletin 520
NEMA
Size
0
1
2
3
4
5
6
7
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
540
810
520E-HO--
520E-HA--
520E-HJ--
225
450
Type 4X
Watertight
CorrosionResistant
Enclosure
FiberglassReinforced
Polyester
Type 4/4X
Watertight
CorrosionResistant
Enclosures
Stainless Stee
Cat. No.
520E-AC--
520E-BC--
520E-CC--
520E-DC--
520E-EC--
520E-FC--
Cat. No.
520E-AS--
520E-BS--
520E-CS--
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
Sa
60 Hz
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, page 1-45.
Vertically Arranged Multi-speed starters, sizes 05, Open Type Without Enclosure can be supplied in a vertically arranged construction. To order, change
the Bulletin number in the listed Cat. No. from 520E to 520VE. Example: Cat. No. 520VE-AOD-A2B-A2B.
Fiberglass reinforced polyester hubs are included with each starter.
Does not include line and load lugs, see page 1-95 for kits.
When using 24V coils on size 4 or 5, an interposing relay may be required.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520E-BAB-6P, and Cat. No.
520E-BCB-6P and will have transformes with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is
desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520E-BABJ-6P, and Cat. No.
520E-BCBJ-6P will have transformers with a 480V primary/24V secondary and a 24V starter coil.
a This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
7 This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-43
Bulletin_520.qxd
05/02/2004
20:30
Page 1-44
Bulletin 520
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each speed. See page 1-152 for heater element
selection tables.
NEMA
Size
0
1
2
3
4
Continuous
Ampere
Rating (A)
18
27
45
90
135
110115V
115120V
200208V
220230V
50 Hz
Pa
60 Hz
50 Hz
60 Hz
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see page 1-45.
Includes drain and cover gasket.
When using 24V coils on size 4 or 5, an interposing relay may be required.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520E-BEB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520E-BEBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
a This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-44
Bulletin_520.qxd
05/02/2004
20:30
Page 1-45
Bulletin 520
Type 4X
Watertight Corrosion-Resistant
Enclosure Fiberglass-Reinforced
Polyester Shown with Optional
Pilot Lights and Push Buttons
Type 4/4X
Watertight Corrosion-Resistant
Enclosure Stainless Steel
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each speed. See page 1-152 for heater element
selection tables.
NEMA
Size
0
1
2
3
4
5
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
Type 4X
Watertight
Type 4/4X
CorrosionWatertight
Resistant
CorrosionEnclosure
Resistant
FiberglassEnclosures
Reinforced
Stainless Steel
Polyester
Cat. No.
Cat. No.
520F-AC-- 520F-AS--
520F-BC-- 520F-BS--
520F-CC-- 520F-CS--
520F-DC--
520F-EC--
520F-FC--
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
Sa
60 Hz
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
A7
440460V
460480V
415V
550V
575600V
500V
the Bulletin number in the listed Cat. No. from 520F to 520VF. Example: Cat. No. 520VF-AOD-A2D-A2D.
Size 6 is a painted enclosure.
Fiberglass reinforced polyester hubs are included with each starter.
For proper overload relay selection, when low speed full load currents are less than 77 A, consult your local Allen-Bradley distributor.
Only available on sizes 05. When using 24V coils on sizes 4 and 5, an interposing relay may be required. See coil VA values on page 1-110.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520F-BAB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520F-BABJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
a This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
7 This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-45
Bulletin_520.qxd
05/02/2004
20:30
Page 1-46
Bulletin 520
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each speed. See page 1-152 for heater element
selection tables.
NEMA
Size
0
1
2
3
Continuous
Ampere
Rating (A)
18
27
45
90
50 Hz
24V
110115V
115120V
200208V
220230V
P
230240V
240V
T
277V
380V
N
380400V
KN
415V
I
440460V
Q
460480V
500V
M
550V
R
575600V
60 Hz
50 Hz
60 Hz
K
J
Voltage
Common Control
Separate Control
(without transformer)
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520F-BEB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520F-BEBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-46
Bulletin_520.qxd
05/02/2004
20:30
Page 1-47
Bulletin 520
Type 4X
Watertight Corrosion-Resistant
Enclosure Fiberglass-Reinforced
Polyester Shown with Optional
Pilot Lights and Push Buttons
Type 4/4X
Watertight Corrosion-Resistant
Enclosure Stainless Steel
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each speed. See page 1-152 for heater element
selection tables.
NEMA
Size
0
1
2
3
4
5
Continuous
Ampere
Rating (A)
18
27
45
90
135
270
Type 4X
Watertight
Type 4/4X
CorrosionWatertight
Resistant
CorrosionEnclosure
Resistant
FiberglassEnclosures
Reinforced
Stainless Steel
Polyester
Cat. No.
Cat. No.
520G-AC-- 520G-AS--
520G-BC-- 520G-BS--
520G-CC-- 520G-CS--
520G-DC--
520G-EC--
520G-FC--
110115V
115120V
200208V
220230V
50 Hz
60 Hz
50 Hz
60 Hz
Da
Voltage
Common Control
Separate Control
(without transformer)
230240V
380V
380400V
KN
240V
277V
440460V
460480V
415V
550V
575600V
500V
the Bulletin number in the listed Cat. No. from 520G to 520VG. Example: Cat. No. 520VG-AOD-A2D-A2D.
Size 6 is a painted enclosure.
Fiberglass reinforced polyester hubs are included with each starter.
Only available in sizes 05. When using 24V coils on sizes 4 and 5, an interposing relay may be required. See coil VA values on page 1-110.
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520G-BAB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520G-BABJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
a This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-47
Bulletin_520.qxd
05/02/2004
20:30
Page 1-48
Bulletin 520
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each speed. See page 1-152 for heater element
selection tables.
NEMA
Size
0
1
2
3
Continuous
Ampere
Rating (A)
18
27
45
90
50 Hz
24V
110115V
115120V
200208V
220230V
P
230240V
240V
T
277V
380V
N
380400V
KN
415V
I
440460V
Q
460480V
500V
M
550V
R
575600V
60 Hz
50 Hz
60 Hz
K
J
Voltage
Common Control
Separate Control
(without transformer)
When selecting a factory-installed control circuit transformer (see Modifications page 1-87), use the Common Control Voltage Suffix Code to denote the
transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520G-BEB-6P will have a
transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Voltage Suffix
Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520G-BEBJ-6P will have a transformer with a 480V primary/24V
secondary and a 24V starter coil.
This coil is optimized for 110115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
This coil is optimized for 115120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
This coil is optimized for 220230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
This coil is optimized for 230240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
1-48
Bulletin_520.qxd
05/02/2004
20:30
Page 1-49
Bulletin 520
Size 04
2-Speed Separate Winding, Constant or Variable Torque and Constant
Horsepower with Eutectic Alloy Overload Relay
or Solid-State Overload Relay
Size 04
2-Speed Consequent Pole, Constant or Variable Torque
with Eutectic Alloy Overload Relay or
Solid-State Overload Relay
Size 04
2-Speed Consequent Pole, Constant Horsepower
with Eutectic Alloy Overload Relay or
Solid-State Overload Relay
1-49
Bulletin_502_Cat_No_Explantion.qxd
05/02/2004
10:57
Page 1-50
Bulletin 502
Bulletin
No.
502
502L
503
503L
506
506X
507
507X
512
512M
513
513M
522E
522F
522G
523E
523F
523G
1232X
1233X
1-50
Bulletin No.
Starter Size
Coil Voltage
Description
A
B
C
D
E
F
G
H
NEMA
Size
0
1
2
3
4
5
6
7
c
Enclosure Type
Code
Type
Type 1: General Purpose, painted metal
enclosure with spring latch door fastener,
A
external overload relay reset, and nonmetallic handle
Type 3R/4/12: Rainproof, watertight,
dusttight, painted metal enclosure with
F
screw fasteners, external overload relay
reset, and non-metallic handle
Type 3R/4/12: Rainproof, watertight,
dusttight, painted metal enclosure with
J
door safety hardware, metal handle, and
NO external overload relay reset
Type 3R/4/12: Rainproof, watertight,
dusttight, painted metal enclosure with
D
door safety hardware, external overload
relay reset, and metal handle
Type 3R: Rainproof, painted metal extracapacity enclosure with screw fasteners,
N
external overload relay reset, and a nonmetallic handle
Type 4/4X: Watertight corrosion-resistant
stainless steel enclosure with screw
C
fasteners, external overload relay reset,
and a stainless steel handle
Type 4/4X: Watertight corrosion-resistant
non-metallic enclosure with screw
S
fasteners, external overload relay reset,
and a non-metallic handle
Type 12: Hazardous location (Class II,
Division 2, Group F + G and Class III,
Divisions 1 + 2) painted metal enclosure
K
with screw fasteners, NO external
overload relay reset and a non-metallic
handle.
Type 12: Hazardous location (Class II,
Division 2, Group F + G and Class III,
L
Divisions 1 + 2) painted metal enclosure
with screw fasteners, external overload
relay reset and a non-metallic handle.
Type 7+9: Hazardous location bolted
E
enclosure, metal handle.
Type 3R/7/9: Hazardous location bolted
H
enclosure, rain proof, metal handle.
Type 3R/7/9: Hazardous location Unilock
U
enclosure, rain proof, metal handle.
Voltage
Code
H
A
B
C
H
A
B
C
HD
AD
BD
CD
Description
Common Control
(without
transformer)
Transformer
Control
Separate Control
(without
transformer)
Line
Voltage
(V)
208
240
480
600
208
240
480
600
208
240
480
600
Coil
Voltage
(V)
208
240
480
600
120
120
120
120
120
120
120
120
e
Overload Relay
Code
Description
None
Eutectic Alloy
See page 1-137
Solid-State
f
Options
See page 1-92
Note
Bulletin_502.qxd
05/02/2004
11:00
Page 1-51
Bulletin 502
Bulletin 502
Table of Contents
Accessories . . . . . . . . . 1-93
Modifications . . . . . . . 1-89
Specifications . . . . . . . 1-109
Full Load Currents
of AC Motors . . . . . . . 1-112
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
Maximum Horsepower
Rating
Full Load Current Must Not
Exceed Continuous Ampere
Rating
Motor
Continuous 60 Hz 60 Hz
NEMA
Ampere
Size
Rating (A) 200V 230V
3
3
0
18
27
45
90
135
270
7-1/2 7-1/2
7-1/2 7-1/2
10
15
10
15
25
30
25
30
40
50
40
50
75
100
Voltage
50 Hz 60 Hz
380 460
415V
575V
10
10
10
25
10
25
25
25
25
50
25
50
50
50
50
75
50
100
75
100
75
100
75
150
150
100
200
200
Line
Voltage
(V)
208240
480600
208240
480600
208240
480600
480600
208240
480600
208240
480600
480600
208240
480600
208240
480600
480600
208240
480600
Fuse Clip
Rating
Amperes (A)
Fuses not
included.
Select per NEC
30
30
30
30
60
60
30
60
60
100
100
60
100
100
200
200
100
200
200
480600
208240
480600
208600
480600
400
200
200
400
400
Type 3R/4/12
Rainproof,
Type 4/4X
Waterproof,
Type 3R/4/12
Watertight
Dusttight
Rainproof,
Corrosion(Door
Resistant
Waterproof,
Safety
Dusttight
Stainless Steel
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
502-AF-24R
502-AF-24R
502-BF-24R
502-BF-24R
502-BF-25R
502-BF-25R
502-CF-24R
502-CF-25R
502-CF-25R
502-CF-26J
502-CF-26J
502-DF-25R
502-DF-26R
502-DF-26R
502-DF-27J
502-DF-27J
502-EF-26R
502-EF-27R
502-EF-27R
502-EF-28J
502-EF-28J
502-FF-27R
502-FF-27R
502-FF-28R
502-FF-28R
Cat. No.
502-AS-24R
502-AS-24R
502-BS-24R
502-BS-24R
502-BS-25R
502-BS-25R
502-CS-24R
502-CS-25R
502-CS-25R
502-CS-26J
502-CS-26J
502-DS-25R
502-DS-26R
502-DS-26R
502-DS-27J
502-DS-27J
502-ES-26R
502-ES-27R
502-ES-27R
502-ES-28J
502-ES-28J
502-FS-27R
502-FS-27R
502-FS-28R
502-FS-28R
Type 1
General
Purpose
Cat. No.
502-AA-24R
502-AA-24R
502-BA-24R
502-BA-24R
502-BA-25R
502-BA-25R
502-CA-24R
502-CA-25R
502-CA-25R
502-CA-26J
502-CA-26J
502-DA-25R
502-DA-26R
502-DA-26R
502-DA-27J
502-DA-27J
502-EA-26R
502-EA-27R
502-EA-27R
502-EA-28J
502-EA-28J
502-FA-27R
502-FA-27R
502-FA-28R
502-FA-28R
Cat. No.
502-AJ-24R
502-AJ-24R
502-BJ-24R
502-BJ-24R
502-BJ-25R
502-BJ-25R
502-CJ-24R
502-CJ-25R
502-CJ-25R
502-CJ-26J
502-CJ-26J
502-DJ-25R
502-DJ-26R
502-DJ-26R
502-DJ-27J
502-DJ-27J
502-EJ-26R
502-EJ-27R
502-EJ-27R
502-EJ-28J
502-EJ-28J
502-FJ-27R
502-FJ-27R
502-FJ-28R
502-FJ-28R
Cat. No.
502-AC-24R
502-AC-24R
502-BC-24R
502-BC-24R
502-BC-25R
502-BC-25R
502-CC-24R
502-CC-25R
502-CC-25R
502-CC-26J
502-CC-26J
502-DC-25R
502-DC-26R
502-DC-26R
502-DC-27J
502-DC-27J
502-EC-26R
502-EC-27R
502-EC-27R
502-EC-28J
502-EC-28J
502-FC-27R
502-FC-27R
502-FC-28R
502-FC-28R
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 502-BFB-24R becomes Cat. No. 502-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 502-AA-24R becomes 502-AA-24. Class J fuse clips can be supplied. Example: Cat. No. 502-AA24R becomes 502-AA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 502-AA-24R becomes 502-AA-24E.
1-51
Bulletin_503.qxd
05/02/2004
11:03
Page 1-52
Bulletin 503
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
Continuous
Ampere
NEMA Rating
Size
(A)
18
27
200V
01/3
1/21
1-1/23
01/3
1/21
1-1/23
5
7-1/2
Motor Voltage
230V
460V
01/3
1/21
01
1-1/23 1-1/23
01/3
01
1-1/23
5
1/21
1-1/23
01
1-1/23
01
1-1/23
57-1/2
57-1/2
10
57-1/2
10
15
2025
15
2025
45
10
10
15
90
1525
2025
30
135
270
30
40
5060
75
40
50
6075
100
3050
6075
100
575V
30
4050
60
75100
125
125150
200
150200
Type 1 General
Purpose
Cat. No.
503-AA-32T
503-AA-35T
503-AA-38T
503-AA-39T
503-BA-32T
503-BA-35T
503-BA-38T
503-BA-39T
503-BA-40T
503-BA-41T
503-CA-41T
503-CA-42T
503-CA-44T
503-DA-44T
503-DA-45T
503-DA-47T
503-EA-45T
503-EA-46T
503-EA-47T
503-EA-48T
503-EA-49T
503-EA-50T
503-FA-48T
503-FA-49T
503-FA-50T
503-FA-51T
503-FA-52T
503-FA-54T
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Cat. No.
503-AF-32T
503-AF-35T
503-AF-38T
503-AF-39T
503-BF-32T
503-BF-35T
503-BF-38T
503-BF-39T
503-BF-40T
503-BF-41T
503-CF-41T
503-CF-42T
503-CF-44T
503-DF-44T
503-DF-45T
503-DF-47T
503-EF-45T
503-EF-46T
503-EF-47T
503-EF-48T
503-EF-49T
503-EF-50T
503-FF-48T
503-FF-49T
503-FF-50T
503-FF-51T
503-FF-52T
503-FF-54T
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight (Door
Safety Hardware)
Cat. No.
503-AJ-32T
503-AJ-35T
503-AJ-38T
503-AJ-39T
503-BJ-32T
503-BJ-35T
503-BJ-38T
503-BJ-39T
503-BJ-40T
503-BJ-41T
503-CJ-41T
503-CJ-42T
503-CJ-44T
503-DJ-44T
503-DJ-45T
503-DJ-47T
503-EJ-45T
503-EJ-46T
503-EJ-47T
503-EJ-48T
503-EJ-49T
503-EJ-50T
503-FJ-48T
503-FJ-49T
503-FJ-50T
503-FJ-51T
503-FJ-52T
503-FJ-54T
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Cat. No.
503-AC-32T
503-AC-35T
503-AC-38T
503-AC-39T
503-BC-32T
503-BC-35T
503-BC-38T
503-BC-39T
503-BC-40T
503-BC-41T
503-CC-41T
503-CC-42T
503-CC-44T
503-DC-44T
503-DC-45T
503-DC-47T
503-EC-45T
503-EC-46T
503-EC-47T
503-EC-48T
503-EC-49T
503-EC-50T
503-FC-48T
503-FC-49T
503-FC-50T
503-FC-51T
503-FC-52T
503-FC-54T
Type 4/4X
Watertight
CorrosionResistant Nonmetallic
Cat. No.
503-AS-32T
503-AS-35T
503-AS-38T
503-AS-39T
503-BS-32T
503-BS-35T
503-BS-38T
503-BS-39T
503-BS-40T
503-BS-41T
503-CS-41T
503-CS-42T
503-CS-44T
503-DS-44T
503-DS-45T
503-DS-47T
503-ES-45T
503-ES-46T
503-ES-47T
503-ES-48T
503-ES-49T
503-ES-50T
503-FS-48T
503-FS-49T
503-FS-50T
503-FS-51T
503-FS-52T
503-FS-54T
208V
60 Hz
230240V
460480V
575600V
HD
AD
BD
CD
To order contactors (0 through 3) with current limiters, change the letter T to D at the end of the listed Cat. No. Example: Cat. No. 503-AA-35D.
1-52
Bulletin_502L.qxd
05/02/2004
11:16
Page 1-53
Bulletin 502L
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
20
30
30
60
60
100
100
200
200
300
300
Line Voltage
(V)
208240
480600
208240
480600
208240
480600
480600
208240
480600
208240
480600
480600
208240
480600
208240
480600
480600
208240
480600
208240
480600
208600
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Cat. No.
502L-AA-24R
502L-AA-24R
502L-BA-24R
502L-BA-24R
502L-BA-25R
502L-BA-25R
502L-CA-24R
502L-CA-25R
502L-CA-25R
502L-CA-26J
502L-CA-26J
502L-DA-25R
502L-DA-26R
502L-DA-26R
502L-DA-27J
502L-DA-27J
502L-EA-26R
502L-EA-27R
502L-EA-27R
502L-EA-28R
502L-EA-28R
502L-FA-28R
Cat. No.
502L-AF-24R
502L-AF-24R
502L-BF-24R
502L-BF-24R
502L-BF-25R
502L-BF-25R
502L-CF-24R
502L-CF-25R
502L-CF-25R
502L-CF-26J
502L-CF-26J
502L-DF-25R
502L-DF-26R
502L-DF-26R
502L-DF-27J
502L-DF-27J
502L-EF-26R
502L-EF-27R
502L-EF-27R
502L-EF-28R
502L-EF-28R
502L-FF-28R
Cat. No.
502L-AJ-24R
502L-AJ-24R
502L-BJ-24R
502L-BJ-24R
502L-BJ-25R
502L-BJ-25R
502L-CJ-24R
502L-CJ-25R
502L-CJ-25R
502L-CJ-26J
502L-CJ-26J
502L-DJ-25R
502L-DJ-26R
502L-DJ-26R
502L-DJ-27J
502L-DJ-27J
502L-EJ-26R
502L-EJ-27R
502L-EJ-27R
502L-EJ-28R
502L-EJ-28R
502L-FJ-28R
Cat. No.
502L-AC-24R
502L-AC-24R
502L-BC-24R
502L-BC-24R
502L-BC-25R
502L-BC-25R
502L-CC-24R
502L-CC-25R
502L-CC-25R
502L-CC-26J
502L-CC-26J
502L-DC-25R
502L-DC-26R
502L-DC-26R
502L-DC-27J
502L-DC-27J
502L-EC-26R
502L-EC-27R
502L-EC-27R
502L-EC-28J
502L-EC-28J
502L-FC-28R
208V
60 Hz
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 502L-BFB-24R becomes Cat. No. 502L-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 502L-AA-24R becomes 502L-AA-24. Class J fuse clips can be supplied. Example: Cat. No. 502LAA-24R becomes 502L-AA-24J. Class HRC form II fuse clips can be supplied. Example: 502L-AA-24R becomes 502L-AA-24E.
1-53
Bulletin_503L.qxd
05/02/2004
11:19
Page 1-54
Bulletin 503L
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
Tungsten Lamp
Loads
(Maximum
480V Line
277V Load)
Maximum Continuous
Ampere Rating (A)
15
20
30
30
60
60
100
100
200
200
300
300
Type 1
General Purpose
Enclosure
Cat. No.
503L-AA-30T
503L-AA-31T
503L-BA-30T
503L-BA-31T
503L-BA-32T
503L-BA-33T
503L-BA-34T
503L-CA-33T
503L-CA-34T
503L-CA-35T
503L-CA-36T
503L-CA-37T
503L-DA-36T
503L-DA-37T
503L-DA-38T
503L-DA-39T
503L-DA-40T
503L-DA-41T
503L-EA-37T
503L-EA-38T
503L-EA-39T
503L-EA-40T
503L-EA-41T
503L-EA-42T
503L-EA-43T
503L-EA-44T
503L-EA-45T
503L-EA-46T
503L-FA-45T
503L-FA-46T
503L-FA-47T
503L-FA-48T
503L-FA-49T
503L-FA-50T
Type 3R/412
Rainproof, Waterproof,
Dusttight Enclosure
Cat. No.
503L-AF-30T
503L-AF-31T
503L-BF-30T
503L-BF-31T
503L-BF-32T
503L-BF-33T
503L-BF-34T
503L-CF-33T
503L-CF-34T
503L-CF-35T
503L-CF-36T
503L-CF-37T
503L-DF-36T
503L-DF-37T
503L-DF-38T
503L-DF-39T
503L-DF-40T
503L-DF-41T
503L-EF-37T
503L-EF-38T
503L-EF-39T
503L-EF-40T
503L-EF-41T
503L-EF-42T
503L-EF-43T
503L-EF-44T
503L-EF-45T
503L-EF-46T
503L-FF-45T
503L-FF-46T
503L-FF-47T
503L-FF-48T
503L-FF-49T
503L-FF-50T
Type 4/4X
Watertight CorrosionResistant Enclosure
Stainless Steel
Cat. No.
503L-AC-30T
503L-AC-31T
503L-BC-30T
503L-BC-31T
503L-BC-32T
503L-BC-33T
503L-BC-34T
503L-CC-33T
503L-CC-34T
503L-CC-35T
503L-CC-36T
503L-CC-37T
503L-DC-36T
503L-DC-37T
503L-DC-38T
503L-DC-39T
503L-DC-40T
503L-DC-41T
503L-EC-37T
503L-EC-38T
503L-EC-39T
503L-EC-40T
503L-EC-41T
503L-EC-42T
503L-EC-43T
503L-EC-44T
503L-EC-45T
503L-EC-46T
503L-FC-45T
503L-FC-46T
503L-FC-47T
503L-FC-48T
503L-FC-49T
503L-FC-50T
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
To order lighting contactors (03) with current limiters, change the letter T to D at the end of the listed Cat. No. Example: Cat. No. 503L-AA-35D.
1-54
Bulletin_506.qxd
05/02/2004
11:27
Page 1-55
Bulletin 506
Bulletin 506
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
y Fusible Versions
cULus Listed (File No.
E125316)(Guide No. NKJH)
y Non-Fusible Versions
cULus Listed (File No.
E3125)(Guide No. NLDX)
y UL 508 and CSA C22.2 No.
14
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page 1-152.
Type 3R/4/12
Max. Hp Rating
Fuse Clip
FLC Must Not Exceed
Type 4/4X
Rainproof,
Rating
Type 3R/4/12
Continuous Amp Rating
Watertight
Waterproof,
Amperes
Type 1
Rainproof,
CorrosionDusttight
Motor Voltage
(A)
General
Waterproof,
(Door Safety
Resistant
Fuses not
Continuous 60 Hz 60 Hz 50 Hz 60 Hz
Purpose
Hardware)
Dusttight
Stainless Steel
included.
Line
Ampere
NEMA
380 460 Voltage Select per
Rating
NEC
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Size
(V)
200V 230V 415V 575V
(A)
506-AA--24R 506-AF--24R 506-AJ--24R 506-AC--24R
3
3
208240
30
0
18
506-AA--24R 506-AF--24R 506-AJ--24R 506-AC--24R
5
5
480600
30
506-BA--24R 506-BF--24R 506-BJ--24R 506-BC--24R
7-1/2 7-1/2
208...240
30
506-BA--24R 506-BF--24R 506-BJ--24R 506-BC--24R
10
10
480...600
30
1
27
506-BA--25R 506-BF--25R 506-BJ--25R 506-BC--25R
7-1/2 7-1/2
208240
60
506-BA--25R 506-BF--25R 506-BJ--25R 506-BC--25R
10
10
480...600
60
208240
60
506-CA--25R 506-CF--25R 506-CJ--25R 506-CC--25R
2
45
25
25
480...600
60
506-CA--26R 506-CF--26R 506-CJ--26R 506-CC--26J
10
15
208240
100
506-CA--26J 506-CF--26J 506-CJ--26J 506-CC--26J
25
25
480...600
100
208240
100
506-DA--26R 506-DF--26R 506-DJ--26R 506-DC--26R
3
90
50
50
480...600
100
506-DA--27J 506-DF--27J 506-DJ--27J 506-DC--27J
25
30
208240
200
506-DA--27J 506-DF--27J 506-DJ--27J 506-DC--27J
50
50
480...600
200
208240
200
506-EA--27R 506-EF--27R 506-EJ--27R 506-EC--27R
4
135
75
100 480...600
200
100 480600
400
400
5
270
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
506-AS--24R
506-AS--24R
506-BS--24R
506-BS--24R
506-BS--25R
506-BS--25R
506-CS--24R
506-CS--25R
506-CS--25R
506-CS--26J
506-CS--26J
506-DS--25R
506-DS--26R
506-DS--26R
506-DS--27J
506-DS--27J
506-ES--26R
506-ES--27R
506-ES--27R
506-ES--28J
506-ES--28J
506-FS--28R
506-FS--28R
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: 506-BFB-24R becomes Cat. No. 506-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 506L-AA-24R becomes 506-AA-24. Class J fuse clips can be supplied. Example: Cat. No. 506AA-24R becomes 506-AA-24J. Class HRC form II fuse clips can be supplied. Example: 506-AA-24R becomes 506-AA-24E.
Bulletin 506 Narrow Enclosure Sizes 0 & 1 are supplied in a (30 in H x 20 in W) enclosure. If a narrow enclosure (27 in H x 10 in W) is required, add the
letter X to the Bulletin Number (506X).
1-55
Bulletin_507.qxd
05/02/2004
11:36
Page 1-56
Bulletin 507
Table of Contents
NEMA
Size
0
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Approximate
Dimensions . . . . . . . . . 1-127
FLC of AC Motors . . 1-112
Standards Compliance
and Certifications
y Circuit Breaker Versions
cULus Listed (File No.
E125316)(Guide No. NKJH)
y Hazardous Locations
cULus Listed (File No.
E138817)(Guide No. NOTH)
y UL 508 and CSA C22.2 No.
14
Heater Elements Starters with eutectic alloy overload relay require 3 heater elements. Located on
Type 3R/4/12
Maximum Horsepower Rating
Rainproof,
Full Load Current Must Not Exceed
Type 3R/4/12
Waterproof,
Continuous Ampere Rating
Type 1
Rainproof,
Dusttight
General
Waterproof,
(Door Safety
Continuous
Purpose
Dusttight
Hardware)
Motor Voltage
Ampere
Rating (A)
200V
230V
460V
575V
Cat. No.
Cat. No.
Cat. No.
100
75100 507-EA--50 507-EF--50 507-EJ--50
page 1-152.
Type 4/4X
Watertight
Corrosion
Resistant
Stainless Steel
Cat. No.
507-AC--32
507-AC--35
507-AC--38
507-AC--39
507-BC--32
507-BC--35
507-BC--38
507-BC--39
507-BC--40
507-BC--41
507-CC--41
507-CC--42
507-CC--44
507-DC--44
507-DC--45
507-DC--47
507-EC--45
507-EC--46
507-EC--47
507-EC--48
507-EC--49
507-EC--50
507-FC--48
507-FC--49
507-FC--50
507-FC--51
507-FC--52
507-FC--54
Type 4/4X
Watertight
Corrosion
Resistant
Non-mettalic
Cat. No.
507-AS--32
507-AS--35
507-AS--38
507-AS--39
507-BS--32
507-BS--35
507-BS--38
507-BS--39
507-BS--40
507-BS--41
507-CS--41
507-CS--42
507-CS--44
507-DS--44
507-DS--45
507-DS--47
507-ES--45
507-ES--46
507-ES--47
507-ES--48
507-ES--49
507-ES--50
507-FS--48
507-FS--49
507-FS--50
507-FS--51
507-FS--52
507-FS--54
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-56
Bulletin_507.qxd
05/02/2004
11:36
Page 1-57
Bulletin 507
NEMA
Size
Heater Elements Starters with eutectic alloy overload relay require 3 heater elements. Located on page 1-152.
Type 7 & 9
Type 3R, 7 & 9
Type 3R, 7 & 9
Maximum Horsepower Rating
Bolted
Bolted
Unilock
Full Load Current Must Not Exceed
Class I, Groups C & D
Class I, Groups C & D
Class I, Groups C & D
Continuous Ampere Rating
Class II, Groups E, F & G Class II, Groups E, F & G Class II, Groups E, F & G
Continuous
Divisions 1 & 2
Divisions 1 & 2
Divisions 1 & 2
Motor Voltage
Ampere
Rating (A)
18
27
200V
01/3
1/21
1-1/23
230V
01/3
1/21
1-1/23
01/3
1/21
1-1/23
5
7-1/2
01/3
1/21
1-1/23
57-1/2
45
10
10
15
90
1525
2025
30
135
30
40
40
50
460V
575V
01
1-1/23
5
01
1-1/23
5
01
1-1/23
01
1-1/23
57-1/2
10
57-1/2
10
15
2025
15
2025
3050
6075
Cat. No.
507-AH--32
507-AH--35
507-AH--38
507-AH--39
507-BH--32
507-BH--35
507-BH--38
507-BH--39
507-BH--40
507-BH--41
507-CH--41
507-CH--42
507-CH--44
507-DH--44
507-DH--45
507-DH--47
507-EH--45
507-EH--46
507-EH--47
507-EH--48
507-EH--49
507-EH--50
Cat. No.
507-AE--32
507-AE--35
507-AE--38
507-AE--39
507-BE--32
507-BE--35
507-BE--38
507-BE--39
507-BE--40
507-BE--41
507-CE--41
507-CE--42
507-CE--44
507-DE--44
507-DE--45
507-DE--47
507-EE--45
507-EE--46
507-EE--47
507-EE--48
507-EE--49
507-EE--50
30
4050
60
75100
Cat. No.
507-AU--32
507-AU--35
507-AU--38
507-AU--39
507-BU--32
507-BU--35
507-BU--38
507-BU--39
507-BU--40
507-BU--41
507-CU--41
507-CU--42
507-CU--44
507-DU--44
507-DU--45
507-DU--47
507-EU--45
507-EU--46
507-EU--47
507-EU--48
507-EU--49
507-EU--50
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the Cat. No. Example: Cat. No. 507-BE--35V.
1-57
Bulletin_512.qxd
05/02/2004
11:42
Page 1-58
Bulletin 512
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
y Fusible Versions
cULus Listed (File No.
E125316)(Guide No. NKJH)
y Non-Fusible Versions
cULus Listed (File No.
E3125)(Guide No. NLDX)
y UL 508 and CSA 22.2 No. 14
y American Bureau of Shipping
3
3
208240
30
0
18
5
5
480600
30
7-1/2 7-1/2
208240
30
10
10
480600
30
1
27
7-1/2 7-1/2
208240
60
10
10
480600
60
25
25
480600
30
10
15
208240
60
25
25
480600
60
2
45
10
15
208240
100
25
25
480600
100
Type 1
General
Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4X
Watertight
CorrosionResistant
Non-Metallic
Cat. No.
512-AA--24R
512-AA--24R
512-BA--24R
512-BA--24R
512-BA--25R
512-BA--25R
512-CA--24R
512-CA--25R
512-CA--25R
512-CA--26J
512-CA--26J
Cat. No.
512-AF--24R
512-AF--24R
512-BF--24R
512-BF--24R
512-BF--25R
512-BF--25R
512-CF--24R
512-CF--25R
512-CF--25R
512-CF--26J
512-CF--26J
Cat. No.
512-AJ--24R
512-AJ--24R
512-BJ--24R
512-BJ--24R
512-BJ--25R
512-BJ--25R
512-CJ--24R
512-CJ--25R
512-CJ--25R
512-CJ--26J
512-CJ--26J
Cat. No.
512-AC--24R
512-AC--24R
512-BC--24R
512-BC--24R
512-BC--25R
512-BC--25R
512-CC--24R
512-CC--25R
512-CC--25R
512-CC--26J
512-CC--26J
Cat. No.
512-AS--24R
512-AS--24R
512-BS--24R
512-BS--24R
512-BS--25R
512-BS--25R
512-CS--24R
512-CS--25R
512-CS--25R
512-CS--26J
512-CS--26J
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 512-BFB-24R becomes Cat. No. 512-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 512-AA-24R becomes 512-AA-24. Class J fuse clips can be supplied. Example: Cat. No. 512-AA24R becomes 512-AA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 512-AA-24R becomes 512-AA-24E.
1-58
Bulletin_512.qxd
05/02/2004
11:42
Page 1-59
Bulletin 512
50
50
480600
60
25
30
208240
100
50
50
480600
100
3
90
25
30
208240
200
50
50
480600
200
75
100 480600
100
40
50
208240
200
75
100 480600
200
4
135
40
50
208240
400
75
100 480600
400
40
50
208240
200
75
100 480600
200
5
270
75
100
150
200 208600
400
6
540
150
200
300
400 208600
600
7
810
300
500
600 240600
1200
Type 1
General
Purpose
Cat. No.
512-DA--25R
512-DA--26R
512-DA--26R
512-DA--27J
512-DA--27J
512-EA--26R
512-EA--27R
512-EA--27R
512-EA--28J
512-EA--28J
512-FA--27R
512-FA--27R
512-FA--28R
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Cat. No.
512-DF--25R
512-DF--26R
512-DF--26R
512-DF--27J
512-DF--27J
512-EF--26R
512-EF--27R
512-EF--27R
512-EF--28J
512-EF--28J
512-FF--27R
512-FF--27R
512-FF--28R
512-GF--29R
512-HF--25L
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Cat. No.
512-DJ--25R
512-DJ--26R
512-DJ--26R
512-DJ--27J
512-DJ--27J
512-EJ--26R
512-EJ--27R
512-EJ--27R
512-EJ--28J
512-EJ--28J
512-FJ--27R
512-FJ--27R
512-FJ--28R
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4X
Watertight
CorrosionResistant
Non-Metallic
Cat. No.
512-DC--25R
512-DC--26R
512-DC--26R
512-DC--27J
512-DC--27J
512-EC--26R
512-EC--27R
512-EC--27R
512-EC--28J
512-EC--28J
512-FC--27R
512-FC--27R
512-FC--28R
512-GC--29R
Cat. No.
512-DS--25R
512-DS--26R
512-DS--26R
512-DS--27J
512-DS--27J
512-ES--26R
512-ES--27R
512-ES--27R
512-ES--28J
512-ES--28J
512-FS--27R
512-FS--27R
512-FS--28R
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 512-BFB-24R becomes Cat. No. 512-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 512-AA-24R becomes 512-AA-24. Class J fuse clips can be supplied. Example: Cat. No. 512-AA24R becomes 512-AA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 512-AA-24R becomes 512-AA-24E.
For 230V and 460V Hp ratings, limit the maximum fuse sizing to 125% of motor full load current.
1-59
Bulletin_512M.qxd
05/02/2004
11:46
Page 1-60
Bulletin 512M
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
y Fusible Versions
cULus Listed (File No.
E125316)(Guide No. NKJH)
y Non-Fusible Versions
cULus Listed (File No.
E3125)(Guide No. NLDX)
y UL 508 and CSA 22.2 No. 14
Heater Elements Starters with eutectic alloy overload relay require 3 heater elements. Located on page 1-152.
Type 3R/4/12
Maximum Horsepower Rating
Type 3R/4/12
Rainproof,
Full Load Current Must Not Exceed
Rainproof,
Waterproof,
Continuous Ampere Rating
Waterproof,
Dusttight (Door
Dusttight
Motor Voltages
Safety Hardware)
Fuse Clip Rating
60 Hz
60 Hz
50 Hz
60 Hz
Amperes (A)
Continuous
Fuses not included.
380
460
NEMA
Ampere
Line
Select per NEC
200V
230V
415V
575V
Cat. No.
Cat. No.
Size
Rating (A)
Voltage (V)
512M-BF--24R 512M-BJ--24R
30
7-1/2
7-1/2
208240
512M-BF--25R 512M-BJ--25R
60
1
27
512M-BF--24R 512M-BJ--24R
30
10
10
480600
512M-BF--25R 512M-BJ--25R
60
512M-CF--25R 512M-CJ--25R
60
10
15
208240
512M-CF--26J 512M-CJ--26J
100
512M-CF--24R 512M-CJ--24R
30
2
45
512M-CF--25R 512M-CJ--25R
60
25
25
480600
512M-CF--26J 512M-CJ--26J
100
Type 4/4X
Watertight,
CorrosionResistant,
Stainless Steel
Cat. No.
512M-BC--24R
512M-BC--25R
512M-BC--24R
512M-BC--24R
512M-CC--25R
512M-CC--26J
512M-CC--24R
512M-CC--25R
512M-CC--26J
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Disconnect Type
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 512M-BFB-24R becomes Cat. No. 512M-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 512M-BA-24R becomes Cat. No. 512M-BA-24. Class J fuse clips can be supplied. Example: Cat.
No. 512M-BA-24R becomes Cat. No. 512M-BA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 512M-BA-24R becomes Cat. No.
512M-BA-24E.
1-60
Bulletin_513.qxd
05/02/2004
11:51
Page 1-61
Bulletin 513
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
NEMA
Size
Heater Elements Starters with eutectic alloy overhead relays require 3 heater elements. Located on page 1-152.
Type 3R/4/12
Maximum Horsepower Rating
Type 4/4X
Rainproof,
Full Load Current Must Not Exceed
Type 3R/4/12
Watertight
Waterproof,
Continuous Ampere Rating
Type 1
Rainproof,
CorrosionDusttight
Waterproof,
General
Resistant
(Door Safety
Continuous
Dusttight
Purpose
Motor Voltages
Stainless Steel
Hardware)
Ampere
Rating (A)
18
27
200V
01/3
1/21
1-1/23
230V
01/3
1/21
1-1/23
01/3
1/21
1-1/23
5
7-1/2
01/3
1/21
1-1/23
10
10
15
45
57-1/2
460V
575V
01
1-1/23
5
01
1-1/23
5
01
1-1/23
01
1-1/23
57-1/2
10
57-1/2
10
15
2025
15
2025
Cat. No.
513-AA--32
513-AA--35
513-AA--38
513-AA--39
513-BA--32
513-BA--35
513-BA--38
513-BA--39
513-BA--40
513-BA--41
513-CA--41
513-CA--42
513-CA--44
Cat. No.
513-AF--32
513-AF--35
513-AF--38
513-AF--39
513-BF--32
513-BF--35
513-BF--38
513-BF--39
513-BF--40
513-BF--41
513-CF--41
513-CF--42
513-CF--44
Cat. No.
513-AJ--32
513-AJ--35
513-AJ--38
513-AJ--39
513-BJ--32
513-BJ--35
513-BJ--38
513-BJ--39
513-BJ--40
513-BJ--41
513-CJ--41
513-CJ--42
513-CJ--44
Cat. No.
513-AC--32
513-AC--35
513-AC--38
513-AC--39
513-BC--32
513-BC--35
513-BC--38
513-BC--39
513-BC--40
513-BC--41
513-CC--41
513-CC--42
513-CC--44
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
513-AS--32
513-AS--35
513-AS--38
513-AS--39
513-BS--32
513-BS--35
513-BS--38
513-BS--39
513-BS--40
513-BS--41
513-CS--41
513-CS--42
513-CS--44
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the Cat. No. Example: Cat. No. 513-BA--35V.
1-61
Bulletin_513.qxd
05/02/2004
11:51
Page 1-62
Bulletin 513
NEMA
Size
3
Heater Elements Starters with eutectic alloy overhead relays require 3 heater elements. Located on page 1-152.
Maximum Horsepower Rating
Full Load Current Must Not Exceed
Continuous Ampere Rating
Hazardous Locations
Type 3R/4/12
Type 4/4X
Rainproof,
Watertight
Waterproof,
Type 3R/4/12
CorrosionRainproof,
Dustlight (Door
Type 1
Waterproof,
Resistant
Safety
Continuous
General Purpose
Stainless Steel
Hardware)
Dustlight
Motor Voltage
Ampere
Rating (A)
90
200V
1525
30
40
135
270
540
810
5060
75
100
125
150
230V
2025
30
40
50
6075
100
125
150
200
250
300
460V
575V
3050
6075
100
30
4050
60
75100
125
125150
200
150200
250
300
250
300
350
450500
450600
Cat. No.
513-DA--44
513-DA--45
513-DA--47
513-EA--45
513-EA--46
513-EA--47
513-EA--48
513-EA--49
513-EA--50
513-FA--48
513-FA--49
513-FA--50
513-FA--51
513-FA--52
513-FA--54
Cat. No.
513-DF--44
513-DF--45
513-DF--47
513-EF--45
513-EF--46
513-EF--47
513-EF--48
513-EF--49
513-EF--50
513-FF--48
513-FF--49
513-FF--50
513-FF--51
513-FF--52
513-FF--54
513-GF--50T
513-GF--51T
513-GF--52T
513-GF--54T
513-GF--56T
513-GF--57T
513-GF--58T
513-GF--59T
513-HF--56T
513-HF--57T
513-HF--61T
513-HF--62T
Cat. No.
513-DJ--44
513-DJ--45
513-DJ--47
513-EJ--45
513-EJ--46
513-EJ--47
513-EJ--48
513-EJ--49
513-EJ--50
513-FJ--48
513-FJ--49
513-FJ--50
513-FJ--51
513-FJ--52
513-FJ--54
Cat. No.
513-DC--44
513-DC--45
513-DC--47
513-EC--45
513-EC--46
513-EC--47
513-EC--48
513-EC--49
513-EC--50
513-FC--48
513-FC--49
513-FC--50
513-FC--51
513-FC--52
513-FC--54
513-GC--50T
513-GC--51T
513-GC--52T
513-GC--54T
513-GC--56T
513-GC--57T
513-GC--58T
513-GC--59T
Type 4/4X
Watertight
CorrosionResistant Nonmetallic
Cat. No.
513-DS--44
513-DS--45
513-DS--47
513-ES--45
513-ES--46
513-ES--47
513-ES--48
513-ES--49
513-ES--50
513-FS--48
513-FS--49
513-FS--50
513-FS--51
513-FS--52
513-FS--54
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-62
Bulletin_513.qxd
05/02/2004
11:51
Page 1-63
Bulletin 513
NEMA
Size
Heater Elements Starters with eutectic alloy overhead relays require 3 heater elements. Located on page 1-152.
Hazardous Locations
Maximum Horsepower Rating
Full Load Current Must Not Exceed
Continuous Ampere Rating
Unilock Enclosure
Bolted Enclosure
Type 3R/7 & 9
Type 7 & 9
Type 3R/7 & 9
Class I, Groups C & D
Class I, Groups C & D
Class I, Groups C & D
Class II, Groups E, F & G Class II, Groups E, F & G Class II, Groups E, F & G
Continuous
Motor Voltage
Divisions 1 & 2
Divisions 1 & 2
Divisions 1 & 2
Ampere
Cat. No.
Cat. No.
Cat. No.
200V
230V
460V
575V
Rating (A)
513-AU--32
513-AE--32
513-AH--32
01/3
01/3
513-AU--35
513-AE--35
513-AH--35
1/21
1/21
01
01
18
513-AU--38
513-AE--38
513-AH--38
1-1/23
1-1/23
1-1/23
1-1/23
513-AU--39
513-AE--39
513-AH--39
5
5
513-BU--32
513-BE--32
513-BH--32
01/3
01/3
513-BU--35
513-BE--35
513-BH--35
1/21
1/21
01
01
513-BU--38
513-BE--38
513-BH--38
1-1/23
1-1/23
1-1/23
1-1/23
27
513-BU--39
513-BE--39
513-BH--39
5
513-BU--40
513-BE--40
513-BH--40
7-1/2
57-1/2
57-1/2
57-1/2
513-BU--41
513-BE--41
513-BH--41
10
10
513-CU--41
513-CE--41
513-CH--41
10
10
513-CU--42
513-CE--42
513-CH--42
15
15
15
45
513-CU--44
513-CE--44
513-CH--44
2025
2025
513-DU--44
513-DE--44
513-DH--44
1525
2025
513-DU--45
513-DE--45
513-DH--45
30
30
90
513-DU--47
513-DE--47
513-DH--47
3050
4050
513-EU--45
513-EE--45
513-EH--45
30
513-EU--46
513-EE--46
513-EH--46
40
40
513-EU--47
513-EE--47
513-EH--47
50
135
513-EU--48
513-EE--48
513-EH--48
60
513-EU--49
513-EE--49
513-EH--49
6075
513-EU--50
513-EE--50
513-EH--50
100
75100
513-FU--48
513-FE--48
513-FH--48
5060
5060
5060
5060
513-FU--49
513-FE--49
513-FH--49
75
6075
513-FU--50
513-FE--50
513-FH--50
100
270
513-FU--51
513-FE--51
513-FH--51
125
513-FU--52
513-FE--52
513-FH--52
125150
513-FU--54
513-FE--54
513-FH--54
200
150200
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-63
Bulletin_513M.qxd
05/02/2004
14:11
Page 1-64
Bulletin 513M
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
NEMA
Size
Heater Elements Starters with eutectic alloy overload relay require 3 overload heater elements. Located on page 1-152.
Maximum Horsepower Rating
Type 4/4X
Full Load Current Must Not Exceed
Type 3R/4/12
Type 3R/4/12 Rainproof,
Watertight,
Continuous
Continuous Ampere Rating
Rainproof, Waterproof,
Waterproof, Dusttight
Corrosion-Resistant,
Ampere Rating
Dusttight
(Door Safety Hardware)
Motor Voltage
Stainless Steel
27
45
200V
01/3
1/21
1-1/23
5
7-1/2
230V
01/3
1/21
1-1/23
10
10
15
57-1/2
460V
575V
01
1-1/23
01
1-1/23
57-1/2
10
57-1/2
10
15
2025
15
2025
Cat. No.
513M-BF--32
513M-BF--35
513M-BF--38
513M-BF--39
513M-BF--40
513M-BF--41
513M-CF--41
513M-CF--42
513M-CF--44
Cat. No.
513M-BJ--32
513M-BJ--35
513M-BJ--38
513M-BJ--39
513M-BJ--40
513M-BJ--41
513M-CJ--41
513M-CJ--42
513M-CJ--44
Cat. No.
513M-BC--32
513M-BC--35
513M-BC--38
513M-BC--39
513M-BC--40
513M-BC--41
513M-CC--41
513M-CC--42
513M-CC--44
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the Cat. No. Example: Cat. No. 513M-BA--35V.
1-64
Bulletin_522.qxd
05/02/2004
14:19
Page 1-65
Bulletin 522
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Approximate
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
y Fusible Versions
cULus Listed (File No.
E125316)(Guide No. NKJH)
y Non-Fusible Versions
cULus Listed (File No.
E3125)(Guide No. NLDX)
y UL 508 and CSA 22.2 No. 14
2-Speed Separate Winding, 3-Pole 3-Pole, Constant or Variable Torque (Constant Horsepower page 1-66)
Heater Elements Starters with eutectic alloy overhead relays require 3 heater elements for each speed located on page 1-152.
Maximum Hp Rating
FLC Must Not Exceed
Continuous Ampere Rating
NEMA
Size
Motor
Continuous 60 Hz 60 Hz
Ampere
Rating
(A)
200V 230V
27
45
90
135
270
Voltage
50 Hz
60 Hz
380
415V
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Cat. No.
Cat. No.
Cat. No.
Type 4/4X
Type 4/4X
Watertight
Watertight
Corrosion-Resistant Corrosion-Resistant
Stainless Steel
Non-metallic
Cat. No.
Cat. No.
208240
30
7-1/2
7-1/2
480600
30
208240
30
10
10
480600
30
208240
60
7-1/2 7-1/2
7-1/2 7-1/2
460
575V
Line
Voltage
(V)
Fuse Clip
Rating
Amperes
(A)
Fuses not
included.
Select per
NEC
10
10
480600
60
10
15
208240
60
25
25
480600
60
10
15
208240
100
25
25
480600
100
25
30
208240
100
50
50
480600
100
25
30
208240
200
50
50
480600
200
40
50
208240
200
75
100
480600
200
40
50
208240
400
522E-EA---28J
522E-EF---28J
522E-EJ---28J
522E-EC---28J
75
100
480600
400
522E-EA---28J
522E-EF---28J
522E-EJ---28J
522E-EC---28J
40
50
208240
200
75
100
480600
200
75
100
150
200
208600
400
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 522E-BFB-24R becomes Cat. No. 522E-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 522E-BA-24R becomes 522E-BA-24. Class J fuse clips can be supplied. Example: Cat. No.
522E-BA-24R becomes 522E-BA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 522E-BA-24R becomes 522E-BA24E.
These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open
delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page 1-67.
1-65
Bulletin_522.qxd
05/02/2004
14:19
Page 1-66
Bulletin 522E
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Maximum Horsepower
Rating
Full Load Current Must Not
Exceed
Continuous Ampere
Rating
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
460
575V
Line
Voltage
(V)
Fuse Clip
Rating
Amperes
(A)
Fuses not
included.
Select per
NEC
208240
30
7-1/2
7-1/2
480600
30
208240
60
7-1/2
7-1/2
480600
60
7-1/2
10
208240
60
Motor Voltage
60 Hz
60 Hz
50 Hz
60 Hz
200V
230V
380
415V
20
20
480600
60
7-1/2
10
208240
100
20
20
480600
100
20
25
208240
100
40
40
480600
100
20
25
208240
200
40
40
480600
200
30
40
208240
200
60
75
480600
200
30
40
208240
400
60
75
480600
400
30
40
208240
200
60
75
480600
200
60
75
100
150
208600
400
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 522E-BFB-24R becomes Cat. No. 522E-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 522E-BA-24R becomes Cat. No. 522E-BA-24. Class J fuse clips can be supplied. Example:
Cat. No. 522E-BA-24R becomes Cat. No. 522E-BA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 522E-BA-24R
becomes Cat. No. 522E-BA--24E.
These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open
delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see page 1-67.
1-66
Bulletin_522.qxd
05/02/2004
14:19
Page 1-67
Bulletin 522F
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
460
575V
Line
Voltage
(V)
Fuse Clip
Rating
Amperes
(A) Fuses
not
included.
Select per
NEC
208240
30
Motor Voltage
60 Hz
60 Hz
50 Hz
60 Hz
200V
230V
380
415V
7-1/2
7-1/2
10
10
480600
30
7-1/2
7-1/2
208240
60
10
10
480600
60
10
15
208240
60
25
25
480600
60
10
15
208240
100
25
25
480600
100
25
30
208240
100
50
50
480600
100
25
30
208240
200
50
50
480600
200
40
50
208240
200
75
100
480600
200
40
50
208240
400
75
100
480600
400
40
50
208240
200
75
100
480600
200
75
100
150
200
208600
400
208V
Common Control
Transformer Control (See page 1-50 Note)
120V Separate Control (without transformer)
60 Hz
230240V
460480V
575600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 522F-BJB-24R becomes Cat. No. 522F-BJB.
Class H fuse clips can be supplied. Example: Cat. No. 522F-BA-24R becomes Cat. No. 522F-BA-24. Class J fuse clips can be supplied. Example:
Cat. No. 522F-BA-24R becomes Cat. No. 522F-BA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 522F-BA-24R
becomes Cat. No. 522F-BA-24E.
1-67
Bulletin_522.qxd
05/02/2004
14:19
Page 1-68
Bulletin 522G
NEMA
Size
ConMotor Voltage
tinuous
Ampere 60 Hz 60 Hz 50 Hz 60 Hz
Rating
380 460
200V 230V 415V
575V
(A)
27
45
90
135
270
Line
Voltage
(V)
Fuse Clip
Rating
Amperes
(A)
Fuses not
included.
Select per
NEC
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
208240
30
7-1/2
7-1/2
480600
30
208240
60
7-1/2
7-1/2
480600
60
7-1/2
10
208240
60
20
20
480600
60
7-1/2
10
208240
100
20
20
480600
100
20
25
208240
100
40
40
480600
100
20
25
208240
200
40
40
480600
200
30
40
208240
200
60
75
480600
200
30
40
208240
400
60
75
480600
400
30
40
208240
200
60
75
480600
200
60
75
150
208600
400
208V
Common Control
Transformer Control (See page 1-50 Note)
120V Separate Control (without transformer)
60 Hz
230240V
460480V
575600V
AD
AD
BD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 522G-BJB-24R becomes Cat. No. 522G-BJB.
Class H fuse clips can be supplied. Example: Cat. No. 522G-BA-24R becomes Cat. No. 522G-BA-24. Class J fuse clips can be supplied. Example:
Cat. No. 522G-BA-24R becomes Cat. No. 522G-BA-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 522G-BA-24R
becomes Cat. No. 522G-BA-24E.
1-68
Bulletin_523.qxd
05/02/2004
14:29
Page 1-69
Bulletin 523
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
cULus Listed (File No. E3125)
Guide No. (NLDX) per UL 508
and CSA 22.2 No. 14
2-Speed Separate Winding, 3-Pole 3-Pole, Constant or Variable Torque (Constant Horsepower page 1-70)
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements for each overload. Located on page 1-152.
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Motor Voltage
200V
230V
460V
575V
01/3
01/3
1/21
1/21
01
01
1-1/23
1-1/23
1-1/23
1-1/23
1-1/23
7-1/2
57-1/2
7-1/2
7-1/2
10
10
10
10
15
15
15
2025
2025
1525
2025
30
30
3050
4050
30
40
40
50
60
6075
100
75100
5060
75
6075
100
125
125150
200
150200
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see page 1-71.
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the Cat. No. Example: Cat. No. 523E-BA---40V.
State horsepower if less than listed.
1-69
Bulletin_523.qxd
05/02/2004
14:29
Page 1-70
Bulletin 523E
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-mettalic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Motor Voltage
200V
230V
460V
575V
01/3
01/3
1/21
1/21
01
01
1-1/22
1-1/22
1-1/23
1-1/23
57-1/2
57-1/2
7-1/2
7-1/2
10
1015
1015
20
20
10
10
1520
1525
25
2530
3040
40
25
30
3040
50
5060
6075
75
40
50
5060
6075
100
100125
125150
150
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
delta connected separate winding motors, use consequent pole starter prices, and furnish complete ordering information, see page 1-71.
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the Cat. No. Example: Cat. No. 523E-BA---40V.
State horsepower if less than listed.
1-70
Bulletin_523.qxd
05/02/2004
14:29
Page 1-71
Bulletin 523F
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Motor Voltage
200V
230V
460V
575V
01/3
01/3
1/21
1/21
01
01
1-1/23
1-1/23
1-1/23
1-1/23
7-1/2
57-1/2
57-1/2
57-1/2
10
10
10
10
15
15
15
2025
2025
1525
2025
30
30
3050
4050
30
40
40
50
60
6075
100
75100
5060
75
6075
100
125
125150
200
150200
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-71
Bulletin_523.qxd
05/02/2004
14:30
Page 1-72
Bulletin 523G
NEMA
Size
Continuous
Ampere
Rating
(A)
27
45
90
135
270
Type 1
General Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
CorrosionResistant
Stainless Steel
Type 4/4X
Watertight
CorrosionResistant
Non-metallic
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Motor Voltage
200V
230V
460V
575V
01/3
01/3
1/21
1/21
01
01
1-1/22
1-1/22
1-1/23
1-1/23
57-1/2
57-1/2
7-1/2
7-1/2
10
1015
1015
20
20
10
1520
1525
25
2530
3040
40
25
30
3040
50
5060
6075
40
50
5060
6070
100
100125
125150
150
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-72
Bulletin_1232X.qxd
05/02/2004
14:33
Page 1-73
Bulletin 1232X
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-129
Standards Compliance
and Certifications
NEMA Size
5
6
7
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page 1-152.
Maximum Horsepower Rating
Fuse Clip
Full Load Current Must Not Exceed
Continuous
Rating
Continuous Ampere Rating
Ampere Rating
Amperes (A)
Motor Voltage
(A)
Line Voltage (V)
Fuses not
60 Hz
60 Hz
50 Hz
60 Hz
included.
Select per NEC
200V
230V
380415V
460575V
7-1/2
7-1/2
208240
30
10
10
480600
30
27
7-1/2
7-1/2
208240
60
10
10
480600
60
10
15
208240
60
25
25
480600
60
45
10
15
208240
100
25
25
480600
100
25
30
208240
100
50
50
480600
100
90
25
30
208240
200
50
50
480600
200
40
50
208240
200
75
100
480600
200
135
40
50
208240
400
75
100
480600
400
75
100
208240
400
270
150
200
480600
400
540
150
200
300
400
208600
600
810
300
500
600
240600
1200
Type 3R
Rainproof
with Extra Panel
Space
Cat. No.
1232X-BN--24R
1232X-BN--24R
1232X-BN--25R
1232X-BN--25R
1232X-CN--25R
1232X-CN--25R
1232X-CN--26J
1232X-CN--26J
1232X-DN--26R
1232X-DN--26R
1232X-DN--27J
1232X-DN--27J
1232X-EN--27R
1232X-EN--27R
1232X-EN--28J
1232X-EN--28J
1232X-FN--28R
1232X-FN--28R
1232X-GN--29R
1232X-HN--25L
60 Hz
208V
230240V
460480V
575600V
AD
AD
CD
CD
1-73
Bulletin_1233X.qxd
05/02/2004
14:39
Page 1-74
Bulletin 1233X
Table of Contents
NEMA
Size
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-129
Standards Compliance
and Certifications
cULus Listed (File No.
E125316)(Guide No. NKJH) per
UL 508 and CSA 22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page 1-152.
Maximum Horsepower Rating
Type 3R
Full Load Current Must Not Exceed Continuous Ampere Rating
Rainproof
Motor Voltage
with Extra Panel Space
Continuous Ampere
Cat. No.
200V
230V
460V
575V
Rating (A)
1233X-BN--32
01/3
01/3
1233X-BN--35
1/21
1/21
01
01
1233X-BN--38
1-1/23
1-1/23
1-1/23
1-1/23
27
1233X-BN--39
5
1233X-BN--40
7-1/2
57-1/2
57-1/2
57-1/2
1233X-BN--41
10
10
1233X-CN--41
10
10
1233X-CN--42
15
15
15
45
1233X-CN--44
2025
2025
1233X-DN--44
1525
25
1233X-DN--45
30
30
90
1233X-DN--47
3050
4050
1233X-EN--45
30
1233X-EN--46
40
40
1233X-EN--47
50
135
1233X-EN--48
60
1233X-EN--49
6075
1233X-EN--50
100
75100
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-74
Bulletin_1233X.qxd
05/02/2004
14:39
Page 1-75
Bulletin 1233X
Continuous Ampere
Rating (A)
270
Motor Voltage
200V
5060
75
540
810
230V
460V
6075
100
100
125
150
125150
200
125
150
200
250
300
350400
250
300
450500
575V
125
150200
250
300
350
400
450600
Type 3R
Rainproof
with Extra Panel
Space
Cat. No.
1233X-FN--48
1233X-FN--49
1233X-FN--50
1233X-FN--51
1233X-FN--52
1233X-FN--54
1233X-GN--50T
1233X-GN--51T
1233X-GN--52T
1233X-GN--54T
1233X-GN--56T
1233X-GN--57T
1233X-GN--58T
1233X-GN--59T
1233X-HN--56T
1233X-HN--57T
1233X-HN--61T
1233X-HN--62T
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-75
Bulletin_1223.qxd
05/02/2004
14:42
Page 1-76
Bulletin 1223
Bulletin 1223
Table of Contents
NEMA Size
1
2
3
4
Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL508
and CSA C22.2 No. 14
Type 3R
Motor Voltage 480 V
Cat. No.
1223-BNB-
1223-CNB-
1223-DNB-
1223-ENB-
Cat. No.
1223-BNC-
1223-CNC-
1223-DNC-
1223-ENC-
Approxmate Dimensions
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing
Dimensions mm (inches)
NEMA
Size
1-4
1-76
A
508
(20)
B
C
D
724
387
664
(28-1/4) (15-1/4) (26-1/8)
E
121
(4-3/4)
F
10
(3/4)
G
635
(25)
Bulletin_530_Cat_No_Explantion.qxd
05/02/2004
14:44
Page 1-77
Bulletin 530
530
B A2D 1 90
a
Code
530
532
533
540
542
543
570
572
573
1242
1243
1272
1273
1282
1283
Bulletin Number
Description
Part Winding Reduced Voltage Starter
Part Winding Reduced Voltage
Combination Starter with Disconnect
Switch
Part Winding Reduced Voltage
Combination Starter with Circuit Breaker
Wye Delta Reduced Voltage Starter
Wye Delta Reduced Voltage Combination
Starter with Disconnect Switch
Wye Delta Reduced Voltage Combination
Starter with Circuit Breaker
Autotransformer Reduced Voltage Starter
Autotransformer Reduced Voltage
Combination Starter with Disconnect
Switch
Autotransformer Reduced Voltage
Combination Starter with Circuit Breaker
Wye Delta Reduced Voltage Pump Panel
with Disconnect Switch
Wye Delta Reduced Voltage Pump Panel
with Circuit Breaker
Autotransformer Reduced Voltage Pump
Panel with Disconnect Switch
Autotransformer Reduced Voltage Pump
Panel with Circuit Breaker
Part Winding Reduced Voltage Pump
Panel with Disconnect Switch
Part Winding Reduced Voltage Pump
Panel with Circuit Breaker
b
Suffix Code
C
D
E
F
G
L
M
P
S
U
Starter Size
NEMA Size
2
3
4
5
6
1YD or 1PW
2YD or 2PW
3YD or 3PW
4YD or 4PW
5YD or 5PW
c
Enclosure Code
Code
Type
Type 1: General Purpose painted
A
enclosure with screw fasteners, external
overload relay reset
Type 3/4/12: Rainproof, watertight,
dusttight, painted metal enclosure with
F
screw fasteners, external overload relay
reset
Type 3R: Rainproof, painted metal extra
N
capacity enclosure with screw fasteners,
external overload relay reset
d
Coil Voltage
Votlage
Line
Description
Code
Voltage (V)
H
208
Common
A
240
Control
(without a
B
480
transformer)
C
600
H
208
A
240
Transformer
Control
B
280
C
600
HD
208
Separate
AD
240
Control
(without a
BD
480
transformer)
CD
600
Coil
Voltage (V)
208
240
480
600
120
120
120
120
120
120
120
120
e
Code
None
See page
1-140
Overload Relay
Type
Eutectic Alloy
Solid-State
f
Options
See page 1-90
Note:
When selecting a factory-installed control circuit transformer use the Transformer Control Voltage Suffix Code to denote the transformer primary voltage. The
transformer secondary voltage and starter coil will both be 120V AC by default. Example: Cat. No. 532-BAB-6P-24R will have a transformer with a 480V
primary voltage, 120V secondary voltage and a 120V starter coil voltage. If a starter coil voltage other than 120V is desired, a second Voltage Suffix Code
must be added to denote the coil and transformer secondary voltage. Example: 532-BABJ-6P-24R will have a transformer with a 480V primary voltage, 24V
secondary voltage and a 24V starter coil voltage.
1-77
Bulletin_530.qxd
05/02/2004
14:50
Page 1-78
Bulletin 530
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Bulletin 530 part winding starters are used with squirrel cage motors
having two separate parallel motor windings.
Standards Compliance
and Certifications
cULus Listed
(File No. E54866) (Guide No.
NITW) per UL 508 and CSA
C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 6 overload heater elements. Located on page 1-152.
Maximum Horsepower Rating
Full Load Current Must Not Exceed
Type 3R/4/12
Continuous Ampere Rating
Type 1
Rainproof, watertight,
Continuous
General Purpose
Motor Voltage
dusttight
Ampere Rating
NEMA Size
(A)
Cat. No.
Cat. No.
200V
230V
460V575V
530-LA--
530-LF--
1PW
54
10
10
15
530-MA--
530-MF--
2PW
90
20
25
40
530-PA--
530-PF--
3PW
180
40
50
75
530-SA--
530-SF--
4PW
270
75
75
150
530-UA--
530-UF--
5PW
540
150
150
350
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-78
Bulletin_532&1282.qxd
05/02/2004
14:53
Page 1-79
Table of Contents
NEMA
Size
1PW
2PW
3PW
4PW
5PW
15
54
10
10
90
15
30
20
25
40
50
180
40
50
75
50
100
270
75
75
150
100
100
200
540
150
150
350
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
575V
15
20
40
60
75
150
300
350
Type 3R/4/12
Rainproof, watertight,
dusttight
Cat. No.
532-LF---24R
532-LF---25R
532-MF---24R
532-MF---25R
532-MF---26J
532-PF---26R
532-PF---27J
532-SF---27R
532-SF---28J
532-UF---28R
532-UF---29J
Type 1
General Purpose
Cat. No.
532-LA---24R
532-LA---25R
532-MA---24R
532-MA---25R
532-MA---26J
532-PA---26R
532-PA---27J
532-SA---27R
532-SA---28J
532-UA---28R
532-UA---29J
Type 3R
Rainproof with extra
panel space
Cat. No.
1282-LN---24R
1282-LN---25R
1282-MN---24R
1282-MN---25R
1282-MN---26J
1282-PN---26R
1282-PN---27J
1282-SN---27R
1282-SN---28J
1282-UN---28R
1282-UN---29J
208V
60 Hz
230...240V
460...480V
575...600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 532-MFB-24R becomes Cat. No. 532-MFB.
1-79
Bulletin_533&1283.qxd
05/02/2004
14:56
Page 1-80
Table of Contents
NEMA Size
1PW
2PW
3PW
4PW
5PW
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Specifications . . . . . . . 1-109
Approximate
Dimensions . . . . . . . . . 1-127
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 6 overload heater elements. Located on page
Maximum Horsepower Rating
Full Load Current Must Not Exceed
Type 1
Type 3R/4/12
Continuous Ampere Rating
General Purpose
General Purpose
Continuous
Enclosure
Enclosure
Motor Voltage
Ampere
Cat. No.
Cat. No.
Rating (A)
200V
230V
460...575V
533-LA---41T
533-LF---41T
10
10
10
54
533-LA---42T
533-LF---42T
15
533-MA---42T
533-MF---42T
15
15
533-MA---43T
533-MF---43T
20
20
20
533-MA---44T
533-MF---44T
90
25
25
533-MA---45T
533-MF---45T
30
533-MA---46T
533-MF---46T
40
533-PA---44T
533-PF---44T
25
533-PA---45T
533-PF---45T
30
30
533-PA---46T
533-PF---46T
40
40
180
533-PA---47T
533-PF---47T
50
50
533-PA---48T
533-PF---48T
60
533-PA---49T
533-PF---49T
75
533-SA---47T
533-SF---47T
50
533-SA---48T
533-SF---48T
60
60
533-SA---49T
533-SF---49T
75
75
270
533-SA---50T
533-SF---50T
100
533-SA---51T
533-SF---51T
125
533-SA---52T
533-SF---52T
150
533-UA---50T
533-UF---50T
100
100
533-UA---51T
533-UF---51T
125
125
533-UA---52T
533-UF---52T
150
150
533-UA---54T
533-UF---54T
200
540
533-UA---56T
533-UF---56T
250
533-UA---57T
533-UF---57T
300
533-UA---58T
533-UF---58T
350
1-152.
Type 3R
General Purpose
Enclosure
Cat. No.
1283-LN---41T
1283-LN---42T
1283-MN---42T
1283-MN---43T
1283-MN---44T
1283-MN---45T
1283-MN---46T
1283-PN---44T
1283-PN---45T
1283-PN---46T
1283-PN---47T
1283-PN---48T
1283-PN---49T
1283-SN---47T
1283-SN---48T
1283-SN---49T
1283-SN---50T
1283-SN---51T
1283-SN---52T
1283-UN---50T
1283-UN---51T
1283-UN---52T
1283-UN---54T
1283-UN---56T
1283-UN---57T
1283-UN---58T
60 Hz
208V
230...240V
460...480V
575...600V
HD
AD
BD
CD
1-80
Bulletin_540.qxd
05/02/2004
16:19
Page 1-81
Bulletin 540
Table of Contents
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Approximate
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page 1-152.
Maximum Horsepower Rating
Full Load Current
Type 3R/4/12
Must Not Exceed
Type 1
Rainproof, watertight,
Continuous Ampere Rating
General Purpose
dusttight
Open Circuit
Open Circuit
Transition
Transition
Motor Voltage
Continuous
460
Ampere Rating
Cat. No.
Cat. No.
NEMA Size
200V
230V
575V
(A)
540-LA-
540-LF-
1YD
47
10
10
1015
540-MA-
540-MF-
2YD
78
1520
1525
2040
540-PA-
540-PF-
3YD
156
2540
3050
5075
540-SA-
540-SF-
4YD
233
5060
6075
100150
540-UA-
540-UF-
5YD
467
75150
100150
200300
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-81
Bulletin_542&1242.qxd
05/02/2004
16:22
Page 1-82
Table of Contents
NEMA Size
1YD
2YD
3YD
4YD
5YD
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Approximate
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page 1-152.
Type 3R/4/12
Maximum Horsepower Rating
Type 1
Type 3R
Rainproof,
Full Load Current Must Not Exceed
General
Rainproof with
watertight,
Continuous Ampere Rating
Purpose
extra panel space
dusttight
Open Circuit
Open Circuit
Open Circuit
Continuous
Transition
Transition
Transition
Motor Voltage
Ampere
200V
230V
460V
575V
Cat. No.
Cat. No.
Cat. No.
Rating (A)
542-LA--24R
542-LF--24R 1242-LN--24R
71/2
71/2
15
15
47
542-LA--25R
542-LF--25R 1242-LN--25R
10
10
20
542-MA--25R 542-MF--25R 1242-MN--25R
78
15
15
40
542-MA--26R 542-MF--26R 1242-MN--26R
20
25
40
208V
60 Hz
230...240V
460...480V
575...600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 542-MFB-24R becomes Cat. No. 542-MFB.
1-82
Bulletin_543&1243.qxd
05/02/2004
16:24
Page 1-83
Table of Contents
NEMA
Size
1YD
2YD
3YD
4YD
5YD
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Approximate
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page 1-152.
Maximum
Horsepower Rating
Full Load Current
Type 3R/4/12
Must Not Exceed
Type 3R
Rainproof,
Continuous Ampere
Type 1
Rainproof with
watertight,
Rating
General Purpose
extra panel space
dusttight
Open Circuit
Open Circuit
Open Circuit
Motor Voltage
Transition
Transition
Transition
Continuous
460
Ampere
Cat. No.
Cat. No.
Cat. No.
200V
230V
575V
Rating (A)
543-LA--41T
543-LF--41T
1243-LN--41T
10
10
10
47
543-LA--42T
543-LF--42T
1243-LN--42T
15
543-MA--42T
543-MF--42T 1243-MN--42T
15
15
543-MA--43T
543-MF--43T 1243-MN--43T
20
20
20
543-MA--44T
543-MF--44T 1243-MN--44T
25
25
78
543-MA--45T
543-MF--45T 1243-MN--45T
30
543-MA--46T
543-MF--46T 1243-MN--46T
40
543-PA--44T
543-PF--44T 1243-PN--44T
25
543-PA--45T
543-PF--45T 1243-PN--45T
30
30
543-PA--46T
543-PF--46T 1243-PN--46T
40
40
156
543-PA--47T
543-PF--47T 1243-PN--47T
50
50
543-PA--48T
543-PF--48T 1243-PN--48T
60
543-PA--49T
543-PF--49T 1243-PN--49T
75
543-SA--47T
543-SF--47T 1243-SN--47T
50
543-SA--48T
543-SF--48T 1243-SN--48T
60
60
543-SA--49T
543-SF--49T 1243-SN--49T
75
233
543-SA--50T
543-SF--50T 1243-SN--50T
100
543-SA--51T
543-SF--51T 1243-SN--51T
125
543-SA--52T
543-SF--52T 1243-SN--52T
150
543-UA--49T
543-UF--49T 1243-UN--49T
75
543-UA--50T
543-UF--50T 1243-UN--50T
100
100
543-UA--51T
543-UF--51T 1243-UN--51T
125
125
543-UA--52T
543-UF--52T 1243-UN--52T
150
150
467
543-UA--54T
543-UF--54T 1243-UN--54T
200
543-UA--56T
543-UF--56T 1243-UN--56T
250
543-UA--57T
543-UF--57T 1243-UN--57T
300
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-83
Bulletin_570.qxd
05/02/2004
16:31
Page 1-84
Bulletin 570
Table of Contents
y Starter sizes: 26
y Overload relays: eutectic supplied as standard, solid-state available
as an option
y Painted metal enclosures: Type 1, Type 3R/4/12
y Modifications factory-installed
y Accessories field-installed
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
NEMA
Size
2
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page 1-152.
Maximum Horsepower Rating
Type 3R/4/12
Full Load Current Must Not Exceed
Rainproof
Continuous Ampere Rating
Watertight
Type 1
Dusttight
Continuous
General Purpose
Motor Voltage
Enclosure
Ampere
Rating (A)
Cat. No.
Cat. No.
200V
230V
460...575V
570-CA--41
570-CF--41
10
570-CA--42
570-CF--42
15
15
45
570-CA--44
570-CF--44
25
570-DA--42
570-DF--42
15
570-DA--44
570-DF--44
25
25
90
570-DA--45
570-DF--45
30
30
570-DA--47
570-DF--47
50
570-EA--45
570-EF--45
30
570-EA--46
570-EF--46
40
135
570-EA--47
570-EF--47
50
570-EA--50
570-EF--50
100
570-FA--47
570-FF--47
50
570-FA--49
570-FF--49
75
75
570-FA--50
570-FF--50
100
270
570-FA--52
570-FF--52
150
570-FA--54
570-FF--54
200
570-GA--50
570-GF--50
100
570-GA--51
570-GF--51
125
125
570-GA--52
570-GF--52
150
150
570-GA--54
570-GF--54
200
540
570-GA--56
570-GF--56
250
570-GA--57
570-GF--57
300
570-GA--59
570-GF--59
400
60 Hz
208V
230...240V
460...480V
575...600V
HD
AD
BD
CD
1-84
Bulletin_572&1272.qxd
05/02/2004
16:35
Page 1-85
Table of Contents
y Starter Sizes 26
y Fusible disconnect switch
y Painted metal enclosure: Type 1 (Bul. 572)
y Painted metal enclosure: Type 3R/4/12 (Bul. 572)
y Painted metal enclosure: Type 3R (Bul. 1272)
y Overload relays: eutectic supplied as standard, solid-state available
as an option
y Modifications Factory installed
y Accessories Field installed
y Service entrance rated
NEMA
Size
2
3
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page
Maximum Horsepower Rating
Full Load Current Must Not Exceed
Type 3R/4/12
Continuous Ampere Rating
Rainproof, watertight,
Type 1
Continuous
Motor Voltage
dusttight
General Purpose
Ampere
200V
230V
460...575V
Cat. No.
Cat. No.
Rating (A)
572-CA--24R
572-CF--24R
5
10
7.5
45
572-CA--25R
572-CF--25R
10
15
25
572-DA--25R
572-DF--25R
15
30
90
572-DA--26R
572-DF--26R
25
30
50
572-EA--25R
572-EF--25R
572-EA--26R
572-EF--26R
30
60
135
572-EA--27J
572-EF--27J
40
50
100
572-FA--27R
572-FF--27R
50
60
125
270
572-FA--28J
572-FF--28J
75
100
200
572-GA--27R
572-GF--27R
125
125
572-GA--28R
572-GF--28R
100
125
540
572-GF--29J
572-GF--29J
150
200
400
1-152.
Type 3R
Rainproof with extra
panel space
Cat. No.
1272-CN--24R
1272-CN--25R
1272-DN--25R
1272-DN--26R
1272-EN--25R
1272-EN--26R
1272-EN--27J
1272-FN--27R
1272-FN--28J
1272-GN--27R
1272-GN--28R
1272-GN--29J
60 Hz
208V
230...240V
460...480V
575...600V
AD
AD
CD
CD
Cat. Nos. listed above include a fusible disconnect switch with Class R fuse clips. To order a non-fusible disconnect switch, eliminate the
fuse clip code from the Cat. No. Example: Cat. No. 572-DFB-24R becomes Cat. No. 572-DFB.
1-85
Bulletin_573&1273.qxd
05/02/2004
16:38
Page 1-86
Table of Contents
y Starter Sizes 26
y Circuit breaker thermal magnetic (inverse time)
y Painted metal enclosure: Type 1 (Bul. 573)
y Painted metal enclosure: Type 3R/4/12 (Bul. 573)
y Painted metal enclosure: Type 3R (Bul. 1273)
y Overload relays: eutectic supplied as standard, solid-state available
as an option
y Modifications Factory installed
y Accessories Field installed
y Service entrance rated
NEMA
Size
2
Modifications . . . . . . . 1-89
Accessories . . . . . . . . . 1-93
Dimensions . . . . . . . . . 1-127
Specifications . . . . . . . 1-109
Standards Compliance
and Certifications
cULus Listed (File No. E54866)
(Guide No. NITW) per UL 508
and CSA C22.2 No. 14
Heater Elements Starters with eutectic alloy overload relays require 3 overload heater elements. Located on page 1-152.
Maximum Horsepower Rating
Type 3R/4/12
Full Load Current Must Not Exceed
Type 3R
Rainproof,
Continuous Ampere Rating
Type 1
watertight,
Rainproof with
Continuous
General Purpose
dusttight
Motor Voltage
extra panel space
Ampere
Cat. No.
Cat. No.
Cat. No.
200V
230V
460...575V
Rating (A)
573-CA--41T
573-CF--41T 1273-CN--41T
10
573-CA--42T
573-CF--42T 1273-CN--42T
15
15
45
573-CA--44T
573-CF--44T 1273-CN--44T
25
573-DA--42T
573-DF--42T 1273-DN--42T
15
573-DA--44T
573-DF--44T 1273-DN--44T
25
25
90
573-DA--45T
573-DF--45T 1273-DN--45T
30
30
573-DA--47T
573-DF--47T 1273-DN--47T
50
573-EA--45T
573-EF--45T 1273-EN--45T
30
573-EA--46T
573-EF--46T 1273-EN--46T
40
135
573-EA--47T
573-EF--47T 1273-EN--47T
50
573-EA--50T
573-EF--50T 1273-EN--50T
100
573-FA--47T
573-FF--47T
1273-FN--47T
50
573-FA--49T
573-FF--49T
1273-FN--49T
75
75
573-FA--50T
573-FF--50T
1273-FN--50T
100
270
573-FA--52T
573-FF--52T
1273-FN--52T
150
573-FA--54T
573-FF--54T
1273-FN--54T
200
573-GA--50T
573-GF--50T 1273-GN--50T
100
573-GA--51T
573-GF--51T 1273-GN--51T
125
125
573-GA--52T
573-GF--52T 1273-GN--52T
150
150
573-GA--54T
573-GF--54T 1273-GN--54T
200
540
573-GA--56T
573-GF--56T 1273-GN--56T
250
573-GA--57T
573-GF--57T 1273-GN--57T
300
573-GA--59T
573-GF--59T 1273-GN--59T
400
60 Hz
208V
230240V
460480V
575600V
HD
AD
BD
CD
1-86
Bulletin_500Line_a.qxd
05/02/2004
16:45
Page 1-87
Modifications Factory-Installed
NEMA Non-Combination Contactors/Starters
For Use on Bulletins 500, 500F, 500L, 500LP, 505, 505V, 509, 520, and 520V
Listed on this and the following pages are factory installed modifications and special features which are available for the low voltage (600 volt
maximum) contactors/starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the
product Cat. No. Example: 509-BAD-A2E-1.
Bulletin 500
Bulletin 500L
Size Rating
Ampere Rating
0
15/20
Description of Modification
Pilot Devices in Cover or Flange
Full Voltage Non-Reversing Single Speed Contactors or
Starters (500, 500F, 500L, 500LP, 509)
START-STOP Push Button
I/O (Canada only)
1
30
2
60
3
100
4
200
5
300
6
540
7
810
NEMA Size
3
4
5
8
1215
9
2250
Suffix
No.
Enclosure
Type
1
1
1
1
1
3R/4/12, 4/4X
Bolted
Unilock
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
1E
1E
1E
1E
1
3R/12, 4/4X, 4X
Bolted
Unilock
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
3
3
3
3
1
3R/12, 4/4X, 4X
Bolted
Unilock
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
A
NA
A
A
NA
NA
NA
3E
3E
3E
3E
1
3R/12, 4/4X, 4X
Bolted
Unilock
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
A
NA
NA
NA
A
NA
NA
NA
00
All Listed
NA
NA
NA
NA
NA
4R
4R
4R
5R
5R
1, 3R/12, 4/4X, 4X
Bolted
Unilock
1, 3R/12, 4/4X, 4X
Bolted
NA
NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
A
NA
NA
NA
NA
A
NA
NA
NA
NA
A
NA
NA
NA
NA
1
1
1
3
3
3
1
1
3
3
3J
4R
1, 3R/12, 4/4X, 4X
Bolted
Unilock
1, 3R/12, 4/4X, 4X
Bolted
Unilock
1, 3R/12, 4/4X, 4X
Bolted
1, 3R/12, 4/4X, 4X
Bolted
1, 3R/12, 4/4X, 4X
1, 3R/12, 4/4X, 4X
A
NA
NA
A
NA
NA
A
NA
A
NA
NA
NA
A
A
NA
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
NA
A
A
A
A
A
A
A
A
NA
A
A
NA
A
A
A
A
A
A
A
A
NA
A
A
NA
A
A
A
A
A
A
A
A
NA
A
A
NA
A
A
A
A
A
A
A
A
NA
A
NA
NA
A
NA
A
NA
A
A
A
NA
NA
A
NA
NA
A
NA
A
NA
A
A
A
NA
NA
A
NA
NA
A
NA
A
NA
A
A
A
NA
NA
A
NA
NA
A
NA
A
NA
A
A
Bulletin 500L and 500FL require a normally open auxiliary contact when used with a push button. See page 1-94. Only one push button or one selector switch
(not both) may be added to a Bulletin 509 for NEMA Type 1 without transformers. Only one pilot light may be added to a Bulletin 509 Type 1 without
transformers.
Bolted suitable for Type 7 & 9 or Type 3R, 7 & 9.
Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9 with the addition of a drain or breather and drain.
OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact add -91 to Cat. No. Red and amber are the only
colors available on Type 1 non-combination starters. On Type 3R/12 non-combination starters, specify other lens colors by changing the letter to: A = Amber;
B = Blue; C = Clear; G = Green; W = White.
For multi-speed and reversing starters, one pilot light for each contactor. Add additional letters to identify two lens colors. The first letter specifies FORWARD,
HIGH, or ON; the second letter specifies REVERSE, LOW, or OFF; e.g., 4AG.
A = Available NA = Not Available
1-87
Bulletin_500Line_a.qxd
05/02/2004
16:45
Page 1-88
Modifications Factory-Installed
NEMA Non-Combination Contactors/Starters
For Use on Bulletins 500, 500F, 500L, 500LP, 505, 505V, 509, 520, and 520V, Continued
Description of Modification
Control Circuit Transformer
Includes 2 Primary Fuses and 1 Secondary Fuse
With Standard Capacity 60 or 50 Hz
With 100 W Extra Capacity 60 or 50 Hz
NEMA Size
3
4
5
Suffix
No.
Enclosure
Type
6P
6P
6P
6XP
6XP
6XP
1, 3R/12, 4/4X, 4X
Bolted
Unilock
1, 3R/12, 4/4X, 4X
Bolted
Unilock
NA
NA
NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
All Listed
All Listed
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
00
Control Circuit
Auxiliary Contact installed on contactor
N.O. 90
N.C. 91
Fused Control Circuit for Applications Less Transformer
(1 Fuse Fuse Included)
(2 Fuses Fuses Included)
Surge Suppression for 120 or 240V AC Coil
21
22
17
1, 3R/12, 4/4X, 4X
1, 3R/12, 4/4X, 4X
All Listed
1, 3R/12, 4/4X, 4X
NA
NA
NA
NA
Open
1, 4/4X, 4X, 12
NA
NA
A
a
A
a
A
a
A
a
A
a
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
9
9A
23
All Listed
All Listed
All Listed
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
400
1, 3R/12, 4/4X, 4X
1, 3R/12
4/4X, 4X
Unilock
1, 3R/12
4/4X, 4X
Unilock
NA
NA
NA
NA
NA
NA
NA
A
NA
NA
NA
A
A
NA
A
A
A
A
A
A
NA
A
A
A
A
A
A
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
A
NA
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
87A
87B
Open Type
Open Type
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
88
All Listed
NA
NA
NA
NA
NA
NA
NA
NA
70
1, 3R/12, 4/4X, 4X
NA
NA
NA
NA
71
1, 3R/12, 4/4X, 4X
NA
NA
NA
NA
72
1, 3R/12, 4/4X, 4X
NA
NA
NA
NA
136
NA
NA
NA
NA
NA
137
NA
NA
NA
NA
NA
Drain
138
Bolted
Unilock
and Bolted
Unilock
and Bolted
NA
NA
NA
NA
NA
426
NA
NA
NA
NA
NA
1, 3R/12, 4/4X, 4
If the transformer secondary is to be grounded, add the suffix letter G at no aditional charge. Example: 6GP.
When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.
Bolted suitable for Type 7 & 9 or Type 3R, 7 & 9.
Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9.
Multiple auxiliary contacts are to be group coded: e.g. use 9 followed by second digit for each auxiliary used: 90-91-98 group coded to 9018. Maximun
quantity of auxuliary contacts (any type) group coded shall be 5.
For Bulletins 505 and 520 devices, one auxiliary contact is installed on each of the two contactors.
a Order by description.
Contactors provided on short mounting plate, consult your local Allen-Bradley distributor for dimensions.
Only one relay per starter.
7 Through control wiring the starter is forced to operate in the low speed before switching to high speed.
1-88
Bulletin_500Line_a.qxd
05/02/2004
16:45
Page 1-89
Modifications Factory-Installed
NEMA Combination Contactors/Starters
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512M, 513, 513M, 522, 522E, 522F, 522G, 523, 523E,
523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, and 1233X
Description of Modification
Pilot Devices in Cover or Flange
START-STOP- Push Button
Transformer Type
Incandescent Bulb
PILOT LIGHT
HAND-AUTO
Full Voltage
Reversing and
Multi-Speed
Starters
HIGH-LOWSTOP Push
Button
Bulletin 522523
NEMA Size
3
4
Suffix
No.
Enclosure Type
1
1
1
1
1E
1E
1E
1E
1L
1L
3
3
3
3
3E
3E
3E
3E
3H
3H
3H
3H
4
4
4
4L
5
5
5L
13
13
1
1
3
3
3
3H
3H
3H
3H
1
1
3R/4/12, 4/4X
Bolted
Unilock
1
3R/4/12, 4/4X
Bolted
Unilock
1
3R/4/12, 4/4X
1
3R/4/12, 4/4X
Bolted
Unilock
1
3R/4/12, 4/4X
Bolted
Unilock
1
3R/4/12, 4/4X
Bolted
Unilock
1, 3R/4/12, 4/4X, 3R
Bolted
Unilock
1, 3R/4/12, 4/4X, 3R
1, 3R/4/12, 4/4X, 3R
Bolted
1, 3R/4/12, 4/4X, 3R
1
3R/4/12, 4/4X
1, 3R/4/12, 4/4X
Bolted (7 & 9)
1, 3R/4X12, 4/4X, 3R
Bolted
Unilock
1
3R/4/12, 4/4X,
Bolted
Unilock
1, 3R/4/12, 4/4X
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
NA
NA
NA
A
NA
NA
NA
NA
NA
A
NA
NA
NA
A
NA
NA
NA
A
NA
NA
A
NA
NA
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
A
NA
NA
NA
A
NA
NA
NA
NA
NA
A
NA
NA
NA
A
NA
NA
NA
A
NA
NA
A
NA
NA
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Bulletin 523
Bolted
NA
NA
Bulletin 522523
Bulletin 523
HIGH-LOW-OFF-AUTO Selector Switch
Transformer Type
Incandescent Bulb
PILOT LIGHT (2)
Transformer TypeLED Bulb
PUSH-TO-TEST
Trans. Incandescent Bulb
PILOT LIGHT
Trans.LED Bulb
3
3
3J
1, 3R/4/12, 4/4X
Bolted
1, 3R/4/12, 4/4X
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
HIGH-OFF-LOW
Selector Switch
1, 3R/4/12, 4/4X
NA
NA
4L
1, 3R/4/12, 4/4X
NA
NA
1, 3R/4/12, 4/4X
NA
NA
5L*
1, 3R/4/12, 4/4X
NA
NA
OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact (-91)
The suffix number is incomplete. Specify the lens with the following letters: A = Amber; B = Blue; C = Clear; G = Green; W = White
For multi-speed and reversing starters, one pilot light for each container. Add additional letter to identify two lens colors. The first letter specifies FORWARD
or HIGH, or ON; the second letter specifies REVERSE or LOW , or OFF; e.g. 4AG
A = Available, NA = Not Available, S = Standard
1-89
Bulletin_500Line_a.qxd
05/02/2004
16:46
Page 1-90
Modifications Factory-Installed
NEMA Combination Contactors/Starters
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512M, 513, 513M, 522, 522E, 522F, 522G, 523, 523E,
523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, and 1233X, Continued
Description of Modification
With Standard Capacity 60 or 50 Hz
With Standard Capacity with Fuse Covers
With Standard Capacity 60 or 50 Hz
With Standard Capacity 60 or 50 Hz
With 100 Watt Extra Capacity 60 or 50 Hz
Control Circuit With 100 Watt Extra Capacity with Fuse Covers
With 100 Watt Extra Capacity 60 or 50 Hz
Transformers
With 100 Watt Extra Capacity 60 or 50 Hz
Includes 2
Primary Fuses
With 200 VA Capacity
and 1 Secondary With 200 VA Capacity with Fuse Covers
Fuse
With 200 Watt Extra Capacity 60 or 50 Hz
With 200 Watt Extra Capacity with Fuse Covers
With 300 Watt Extra Capacity 60 or 50 Hz
With 300 Watt Extra Capacity with Fuse Covers
With 400 Watt Extra Capacity 60 or 50 Hz
With 400 Watt Extra Capacity with Fuse Covers
Auxiliary Contact installed on
N.O.
contactors
N.C.
Auxiliary Contact Contactor (Four Maximum) N.C.
Late Break
Auxiliary Contact installed on
N.O.
Auxiliary
disconnect
N.C.
Contacts
N.O.
N.O.
Auxiliary Contact installed on
N.O.
circuit breaker (external to breaker)
to operate with handle (two
N.C.
maximum)
N.C.
N.C.
1 Fuse Fuse
Included
1 Fuse with
Protective
Cover Fuse
Included
Control Circuit Fuse Block Less
Transformer
2 Fuses
Fuses Included
2 Fuse with
Protective
Control Circuit
Cover Fuse
Included
Surge Suppression for 120V or 240V AC Coil
Terminal Blocks
6-Point Block
(Cat No. 1492-HC6)
Terminal Blocks
12-Point Block
(Cat No. 1492-HC12)
N.O. Alarm Contact Adder (Bulletin 592)
Accessories
For Bulletins
506, 506X, 507,
507X Deduct
For Bulletins
522, 523 Deduct
3 Powermonitor (Timemark Model 258)
Bulletin 596 (Used on Bulletin
On Delay
500509, 3-Pole Maximum
Off Delay
Form A Compelling Relay (Used on Bulletin 522523)
Form B Auto. Seq. Accelerating Relay for each higher
speed (used on Bulletin 522523)
Form C Auto. Seq. Decelerating Relay for each higher
speed (used on Bulletin 522523)
Omit Three Overload Relays
Enclosure Type
1, 3R/4X/12, 4/4X, 3R
1, 3R/4X/12, 4/4X, 3R
Bolted
Unilock
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
Bolted
Unilock
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 4X
1, 3R/4X/12, 4/4X
Bolted
0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
1
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NEMA
3
A
A
A
A
A
A
A
A
NA
NA
A
A
A
A
A
A
A
A
97
1, 3R/4/12, 4/4X 3R
98
99
98
98
98
99
99
99
1, 3R/4/12, 4/4X 3R
1, 3R/4/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
Bolted
Unilock
1, 3R/4X/12, 4/4X 3R
Bolted
Unilock
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
21
1, 3R/4X/12, 4/4X 3R
21C
1, 3R/4X/12, 4/4X 3R
22
1, 3R/4X/12, 4/4X 3R
22C
1, 3R/4X/12, 4/4X 3R
17
7
A
A
NA
NA
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
A
NA
NA
A
A
A
NA
NA
A
NA
NA
1, 3R/4X/12, 4/4X, 3R
Bolted
Unilock
NA
NA
TB6
1, 3R/4X/12, 4/4X, 3R
TB12
1, 3R/4X/12, 4/4X, 3R
1, 3R/4X/12, 4/4X 3R
Bolted
Unilock
NA
NA
NA
NA
NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
A
NA
NA
NA
23
23
1, 3R/4X/12, 4/4X 3R
Bolted
Unilock
400
87A
87B
70
1, 3R/4X/12, 4/4X 3R
Bolted (3R, 7 & 9)
Unilock (7 & 9)
1, 3R/4/12, 4/4X
A
A
A
A
71
1, 3R/4/12, 4/4X
NA
NA
72
1, 3R/4/12, 4/4X
NA
NA
Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9 with the addition of a drain or a breather and drain.
For Bulletins 506, 507, 522 and 523 devices. One auxiliary contact is installed on each of the two contactors.
A = Available, NA = Not Available, S = Standard
1-90
Size
4
5
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA NA
NA NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
6
A
A
NA
NA
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
A
NA
9A
Suffix
No.
6P
6PC
6P
6P
6XP
6XPC
6XP
6XP
6XXP
6XXPC
6YP
6YPC
6XYP
6XYPC
6YYP
6YYPC
90
91
Bulletin_500Line_a.qxd
05/02/2004
16:46
Page 1-91
Modifications Factory-Installed
NEMA Combination Contactors/Starters
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512M, 513, 513M, 522, 522E, 522F, 522G, 523, 523E,
523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, and 1233X, Continued
Circuit
Breakers
Description of Modification
Marine Requirements
Add the letter C to the
Current Limiters instantaneous circuit breaker no.
code.
Thermal
Add the letter T to the circuit
Magnetic Circuit
breaker no. code.
Breakers
Add the letter D to the inverse
Current Limiters
time circuit breaker no. code.
Enclosure
Accessories
NEMA Size
3
4
A
A
Suffix
No.
345
Enclosure Type
0
A
1
A
2
A
1, 3R/4X/12, 4/4X 3R
1, 3R/4X/12, 4/4X 3R
5
A
6
NA
7
NA
NA
NA
1, 3R/4X/12, 4/4X 3R
NA
NA
Breather
136
Bolted
NA
NA
137
NA
NA
Drain
138
NA
NA
203W
1, 3R/4/12, 3R
NA
NA
412
413
419
1, 3R/4/12, 3R
4/4X
1, 3R/4/12, 4/4X, 3R
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
S
S
NA
S
S
NA
S
S
NA
414
1, 3R/4/12, 4/4X 3R
NA
NA
A
A
A
A
A
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
A
NA
A
A
A
A
NA
NA
NA
A
NA
415
416
417
418
420
421
424
425
426
1, 3R/4/12, 4/4X, 3R
1, 3R/4/12, 4/4X, 3R
1, 3R/4/12, 4/4X, 3R
1, 3R/4/12, 4/4X, 3R
3R
3R
1, 3R/12, 4/4X, 4
Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9 with the addition of a drain or a breather and drain.
A = Available, NA = Not Available, S = Standard
1-91
Bulletin_500Line_Contents.qxd
05/02/2004
16:50
Page 1-92
Accessories
NEMA Non-Combination Contactors/Starters and Combination Contactors/Starters
Contactor/Starter Accessories
y Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Surge Suppressors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Terminal and Lug Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Tie Point Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Protective Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Timer Attachments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Power Pole Adders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Contactor Kick-Off Springs . . . . . . . . . . . . . . . . . . . . . . . . . .
y Device Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Top Wiring Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Terminal Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Adapter Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Single Pole Fuse Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Auxiliary Contact Adder Decks . . . . . . . . . . . . . . . . . . . . . . .
y 24V DC Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Latch Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Interposing Contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overload Relay Accessories
y Auxiliary Contacts for Eutectic Alloy Overload Relays .
y DIN Rail Mounting Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage Control Accessories
y Transformers with Top-Mounted Fuse Blocks
(For Use on Non-Combination Starters) . . . . . . . . . . . . . .
y Fuse Block Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Fuse Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pilot Device Accessories
y Selector Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Pilot Light Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Push-to-Test Pilot Light Kits . . . . . . . . . . . . . . . . . . . . . . . . . .
y Optional Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Additional Pilot Light Devices . . . . . . . . . . . . . . . . . . . . . . . .
y Pilot Light Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Replacement Bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enclosure Accessories
y Conduit Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Grounding Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Hole Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Door Safety Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Breather . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Breather-Drain Combination . . . . . . . . . . . . . . . . . . . . . . . . . .
y Reset Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
y Ground Lug Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-92
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
1-93
1-93
1-93
1-93
1-93
1-94
1-94
1-94
1-94
1-95
1-95
1-95
1-95
1-95
1-95
1-95
1-95
1-95
Page 1-96
Page 1-96
Page 1-97
Page 1-98
Page 1-98
Page 1-99
Page 1-99
Page 1-100
Page 1-100
Page 1-100
Page 1-101
Page 1-101
Page 1-101
Page
Page
Page
Page
Page
Page
Page
Page
Page
1-102
1-102
1-102
1-103
1-103
1-103
1-103
1-103
1-103
Page
Page
Page
Page
Page
1-104
1-104
1-104
1-104
1-104
Page 1-105
Page 1-105
Page 1-105
Page
Page
Page
Page
Page
1-106
1-106
1-106
1-106
1-106
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-93
Contactor Accessories
For use on Bulletins 500, 500F, 500L, 500FL, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512,
512M, 513, 513M, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283,
1232X, and 1233X
NEMA
Size
Description
Coils (60 Hz)
115120V
200208V
230240V
460480V
575600V
115120V
200208V
230240V
460480V
575600V
115120V
200208V
230240V
460480V
575600V
115120V
200208V
230240V
460480V
575600V
115120V
200208V
230240V
56136V AC/
78180V DC
137277V AC/
181350V DC
278575V AC
12120V AC
RC
12240V AC
Varistor
12120V AC
RC mod
12120V AC
Varistor
120V AC
Terminal and
Lug Covers
CB-236
01
5
(SER.)
CB-249
CB-254
CB-273
CB-278
CC-236
CC-249
CC-254
CC-273
CC-278
CD-236
CD-249
CD-254
CD-273
CD-278
CE-236
CE-249
CE-254
CE-273
CE-278
CF-236
AF-249
AF-254
Description
Cat. No.
Line side
terminal covers
Line side
terminal covers
(reversing)
Tie Point
Terminal
Description
Protective
Covers
100-FSV575
599-K04
05
599-KA04
199-GSMA1
78
01
599-TC01R
3
4
5
3
4
599-LC-3-L
599-LC-4-L
599-LC-5-L
599-LC-3-T
599-LC-4-T
599-LC-5-T
02
599-TP02
35
599-TP34
100-FSV277
Cat. No.
599-TC01N
599-TC2N
599-TC3N
599-TC4N
599-TC5N
100-FSV136
199-FSMA1
NEMA
Size
01
2
3
4
5
599-PS01
No. of Poles
NEMA Size
Cat. No.
01
599-PC01
01
599-PS01
5
5
01
01
599-PC01-5
599-PS01-5
599-PC2
599-PS2
5
5
2
2
599-PC2-5
599-PS2-5
599-PC3
599-PS3
5
5
3
3
599-PC3-5
599-PS3-5
599-PC4
599-PS4
5
5
4
4
599-PC4-5
599-PS4-5
599-PC5
599-PS5
700-N24
1-93
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-94
Right-hand OFF
Delay
596-TR33
1-94
1 N.O.
2 N.O.
1 N.C.
2 N.C.
1 N.O. and N.C.
1 N.C.L.B.
Single Pole N.O.
Auxiliary Contact
for Disconnect
Switch 1 N.O.
1 N.O.
Two-Pole N.O.
Auxiliary Contact
for Disconnect
Switch 2 N.O.
2 N.O.
2 N.O.
1 N.C.
1 N.C.
2 N.C.
2 N.C.
2 N.C.
1 N.O. and N.C.
2 N.O.
2 N.O.
1 N.C.L.B.
NEMA
Size
05
05
05
05
05
05
Cat. No.
595-A
595-AA
595-B
595-BB
595-AB
595-BL
195-GA10
1495-J6
195-GA20
78
9
6
79
6
78
9
6
78
9
6
1495-K6
1495-K8
195-GB01
1495-J6
195-GB02
1495-K6
1495-K8
195-GB11
1495-K6
1495-K8
195-GL01
NEMA
Description
Size
Cat. No.
Power Pole Adders The 1 N.O. and 1 N.C. power poles may be field
added to all Size 0 through 4 Bulletin 500 line contactors and starters except
the Bulletin 500L and 500FL. Two and three pole contactors will accept a
maximum of two adder poles and four pole devices will accept one adder
pole. Each adder pole kit includes a mechanical load balancer to be used
when only one power pole is added. Note: When power poles are added to
Size 2, 3 or 4 (2- or 3-pole devices) the operating coil must be changed.
Refer to the listing for the size of your contactor or starter. Order the
operating coil listed for a 45 pole device.
Note: These coils can also be factory installed.
599-P01A
1 N.O.
1 N.C.
01 599-P01B
1 N.C. Late Break
599-P01BL
599-P2A
1 N.O.
599-P2B
1 N.C.
2
599-P2BL
1 N.C. Late Break
599-P3A
1 N.O.
3
1 N.C.
599-P3B
599-P4A
1 N.O.
4
599-P4B
1 N.C.
Contactor Kick-off Springs For horizontal mounting of 2- or 3-pole
Bulletin 500 contactors and starters.
Note: When kick-off springs are added to Size 2, 3 or 4, the operating coil
must be changed. Refer to the listing for the size of your contactor or starter.
Order the operating coil listed for a 4-pole device.
Note: These coils can also be factory installed.
599-N11
01
599-N12
2
599-N13
3
45
599-N14
NEMA
Size
Cat. No.
01
2
3
4
5
1494R-N1
1494R-N2
1494R-N3
1494R-N10
Description
Lug Connectors (3 per package)
Wire Size
# 148 AWG Wire
# 144 AWG Wire
# 81/0 AWG Wire
# 64/0 AWG Wire
Cat. No. 1494R-N3 2 of # 1/0350 MCM Wire
NEMA Size
Cat. No.
199-LJ1
78
199-LG1
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-95
NEMA
Size
Cat. No.
05
599-FR04
Note: One cover per pole is required. Example: Transformer with top-mounted
fuse block requires three covers. Fuse block kit for separate control
requires two covers.
Enclosure
Description
Type
Adapter Plates
For replacement of:
y Allen-Bradley
(Bulletin 709 Series K)
y Cutler Hammer
(Citation & Freedom
Series)
1 (hinged),
y Furnas (Class 14
3R,
and ESP 100)
3R/4/12,
y General Electric
4/4X
(Series 300)
(stainless)
y Joslyn-Clark (Type
HP)
y Square D (Type S)
y Westinghouse
(A200 and W200
Advantage)
NEMA
Size
0, 1
NEMA
Description
Size
Cat. No.
Auxiliary Contact Adder Decks The same 2- and 4-pole auxiliary
contact blocks in various combinations of normally open and normally
closed will slide and snap onto the front of the contactor. Adder decks have
convenient backed out wire clamps to make lugging of control wires
unnecessary. Fits on Open Type devices only.
100-FA20
2 N.O.
1 N.O. -1 N.C.
100-FA11
2 N.C.
100-FA02
4 N.O.
100-FA40
00
100-FA31
3 N.O.-1 N.C.
2 N.O. -2 N.C.
Cat. No.
599-CP01
599-CP2
100-FA22
100-FA04
4 N.O.
4-pole
24 Volt DC Interface Module Mounts to the top of the contactor. It
provides a 24V DC, 0.5 watt input signal which can be used to operate the
24 through 240V AC coil of the contactor. Fits on Open Type devices only.
00
100-JE
00
100-FL11
500-NX100D
120V 60 Hz
6
Interposing Contactor For
Open Type Bulletin 500 and 500L. 240V 60 Hz
500-NX100A
6
Device Markers Snap easily into the coil cover of contactors and starters
for component identification. A maximum of five markers will fit on each
contactor or starter. (Standard: 50 Device Markers per Package)
05
599-DM 5
599-TW01
01
2
599-TW2
3
599-TW3
599-TW4
599-TW5P
24V
K
J
48V
Y
100V
KP
110V
D
120V
230V
240V
VA
240V
T
A
277V
380
400V
N
400
415V
G
400V
B
N
480V
To complete Cat. No. insert in the third position the desired numeric symbol (05) or one of the following letters A, B, C, D, E, F, H, L, M, P, R, S, T, U, or W.
1-95
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-96
Auxillary Contact
For Eutectic Alloy Overload Relays Only
Contact Ratings
NEMA A600 (10 A, 600V AC max.)
NEMA P300 (5 A, 300V DC max.)
Auxiliary Contact
For Eutectic Alloy Overload Relays Only
1 N.O.
1 N.C.
1 N.O.
1 N.C.
1 N.O.
00 3-phase
00 3-phase
595-A00
595-B00
595-A02
595-B02
595-A34
34
Enclosure Type
DIN Rail Mounting Adapter for
Bulletin 592 Compact Type
Overload Relays
For 3-pole Overload Relays
DIN Rail Mounting Adapter for
Bulletin 592 Compact Type
Overload Relays
For 1-pole Overload Relays
Cat. No.
02, 59
1 N.C.
Description
NEMA Size
595-B34
NEMA Size
Cat. No.
40 A
599-MP1
62 A
599-MP2
1 (hinged), 3R,
3R/4/12, 4/4X
(stainless)
1-96
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-97
Primary
Voltage
208V
240V & 480V
600V
208V
240V & 480V
600V
208V
240V & 480V
600V
208V
240V & 480V
600V
208V
240V & 480V
600V
Standard
Cat. No.
VA
1497-N1PK
80 1497-N2PK
1497-N3PK
1497-N4PK
200 1497-N5PK
1497-N6PK
1497-N7PK
250 1497-N8PK
1497-N9PK
1497-N10PK
350 1497-N11PK
1497-N12PK
1497-N18PK
500 1497-N19PK
1497-N20PK
Voltage
300 W Extra
VA
Cat. No.
1497-N10PK
350 1497-N11PK
1497-N12PK
1497-N18PK
500 1497-N19PK
1497-N20PK
1497-N10PK
350 1497-N11PK
1497-N12PK
1497-N10PK
350 1497-N11PK
1497-N12PK
400 W Extra
VA
Cat. No.
1497-N18PK
500 1497-N19PK
1497-N20PK
1497-N18PK
500 1497-N19PK
1497-N20PK
1497-N18PK
500 1497-N19PK
1497-N20PK
1497-N18PK
500 1497-N19PK
1497-N20PK
NEMA Size
02
Primary Voltage/
3 Pole Fuse Block
208V
240V & 480V
600V
208V
240V & 480V
600V
208V
240V & 480V
600V
208V
240V & 480V
600V
Transformers can be installed in Type 1, 3R, 3R/4/12 painted enclosures and Type 4/4X stainless steel enclosures.
Type 4/4X non-metallic enclosures and Type 7 & 9 hazardous location enclosures require transformers with separately mounted fuse blocks. For a complete
listing of transformers see page 8-13.
1-97
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-98
These control circuit fusing kits are intended to be used for control circuit transformer protection and protection of control circuits capable of
delivering no more than 200 000 RMS symmetrical amperes, 600V maximum. (Fuses not included)
Description
One-Pole Kit Panel-Mounted (Midget Fuse)
Control Circuit Fuse Block
For Class CC Rejection Type Fuses (Fuses Not Included)
Two-Pole Kit Panel-Mounted (Two Midget Fuses)
Three-Pole Kit Panel-Mounted (One Midget Fuse/Two Class CC Fuses)
Three-Pole Kit Panel-Mounted (Three Class CC Fuses)
Single-Pole Kit Bulletin 500 Line Controller Mounted (Class CC Fuses)
One-Pole Kit Panel-Mounted (3160 A Class J Fuse)
One-Pole Kit Panel-Mounted (61100 A Class J Fuse)
One-Pole Kit Transformer Mounting Only 30 A/250V)
Cat. No.
1491-R165
1491-R162
1491-R167
1491-R169
1491-R171
599-FR04
1491-R173
1491-R175
1491-N100
For control circuit transformers with a 350 VA or larger rating, it is recommended that Bussmann Type FNQ-R, Ferraz-Shawmut Type ATDR, Littelfuse Type
1-98
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-99
START-STOP
FOR-REV-STOP
HIGH-LOW-STOP
Enclosure Type
00
02
1 (Lift-off)
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
NEMA
Size
non-metallic)
non-metallic)
05
non-metallic)
non-metallic)
1 (Lift-off)
35
02
3R, 7 & 9
35
1 (Lift-off)
00
02
35
1, 3R/4/12
4, 4X (stainless steel and non-metallic)
1, 3R/4/12
4, 4X (stainless steel and non-metallic)
1, 3R/4/12
4, 4X (stainless steel and non-metallic)
05
START-STOP (Unilock)
7&9
START-STOP (Bolted)
02
35
29
Cat. No.
599-SS00
599-SS02
599-SS09HJ
599-SS09HS
599-SS09OJ
599-SS09OS
599-SS09RJ
599-SS09RS
599-SS09TJ
599-SS09TS
599-SS34
1481-N48
1481-N54
1481-N55
1481-N59
1481-N60
1481-N62
599-PB00
599-PB02
599-PB34
599-PB09SJ
599-PB09SS
599-PB09RJ
599-PB09RS
599-PB09WJ
599-PB09WS
1481-N53
1481-N58
Use
800H-DPH16AAXX64
Bulletins 500, 505, 509, 520 with control transformer are supplied from the factory in Type 1 (Hinged) enclosures.
1-99
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-100
Enclosure Type
NEMA
Size
ON
non-metallic)
non-metallic)
05
non-metallic)
non-metallic)
00
02
39
1 (Lift-off)
Cat. No.
599-PL09DJ
1, 3R/4/12
599-PL09DS
599-PL09AJ
599-PL09AS
599-PL09BJ
599-PL09BS
599-PL09CJ
599-PL09CS
599-PL00
599-PL02
599-PL34
800T-N26R
All
05
3R, 7 & 9
(Unilock)
05
599-PT09DJ
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
1, 3R/4/12
4, 4X (stainless steel and
800T-N26G
800T-N26A
800T-N26B
800T-N26C
800T-N26W
1481-N56A120R
1481-N56A120G
non-metallic)
non-metallic)
05
non-metallic)
non-metallic)
599-PT09DS
599-PT09AJ
599-PT09AS
599-PT09BJ
599-PT09BS
599-PT09CJ
599-PT09CS
800T-N40
All
05
800T-N41
800T-N42
800T-N43
800T-N45
800T-N44
115120V
D
230240V
A
460480V
B
Bulletins 500, 505, 509, 520 with control transformer are supplied from the factory in Type 1 (Hinged) enclosures.
Pilot light kits and push-to-test pilot light kits include one green and one red cover as standard.
An adapter (Cat. No. 1481-N61) is required for each pilot light added to Size 3, 4 and 5 Unilock enclosures.
Supplied with Red Lens Only.
Note: Bulletins 505, 520 with 2 pilot lights are supplied in hinged enclosures, with or without control circuit transformers.
1-100
575600V
C
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-101
Enclosure
Type
NEMA
Size
Cat. No.
1481-N56A120R
05
1481-N56A120G
3R, 7 & 9
(Unilock)
1481-NX1
005
1481-NX2
1481-NX3
800T-N169
800T-N320A
800T-N320G
800T-N320R
800T-N320B
800T-N65
800T-N318A
1, 3R/4/12
09
4/4X, 4X
09
3R, 7 & 9
09
800T-N318G
800T-N318R
800T-N318B
Use Bulletin 800T devices
(See page 10-50)
Use Bulletin 800H
Type 4X devices
(See page 10-50)
Use Bulletin 800H
Type 7 & 9 devices
(See page 10-133)
When the control voltage is other than 120V, 60 Hz or 110V, 50 Hz it is necessary to also use one of the following transformers.
An adaptor (Cat. No. 1481-N61) is required for each pilot light added to size 3, 4 and 5 Unilock enclosures.
1-101
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-102
Enclosure Type
1, 3R/4/12, 3R
NEMA
Size
Cat. No.
01
1232-N11
2
3
4
1232-N12
1232-N13
1232-N14
1232-N15
1490-N1
01
2
3
4
5
1490-N9
1490-N10
1490-N11
1490-N5
1490-N6
1490-N7
1490-N8
1490-N19
01
2
3
4
5
1, 3R, 3R/4/12
1494F-M1
04
1494F-S1
1494F-P1
Hole Plugs
30.5mm hole plug for pilot devices
1490-N20
1490-N21
1490-N22
1490-N23
1490-N24
1490-N25
1490-N26
800T-N1
All
05
598-N1
Bulletin 1490 grounding adapters are available for use with these conduit hubs. These bushings provide a convenient method of connecting a ground wire to
the conduit system. See conduit connector (hub) above proper size.
1-102
Bulletin_500Line_b.qxd
05/02/2004
17:08
Page 1-103
Enclosure Type
NEMA
Size
Cat. No.
02
1494F-V1
04
34
1494F-V2
1494F-V3
1494F-V4
3R/4/12
56 in. x 30 in. x 14 in.
Breather
Bulletin 505, 507, 509, and 513 Unilock and Bolted
Class I, Groups C and D
Class II, Groups E, F and G
Drain
Bulletin 505, 507, 509, and 513 Unilock and Bolted
Class I, Groups C and D
Class II, Groups E, F and G
Breather Drain Combination
Bulletin 505, 507, 509, and 513 Unilock and Bolted
Class I, Groups C and D
Class II, Groups E, F and G
1401-N1
05
1401-N2
1401-N3
02
35
599-GR1
599-GR2
67
599-GR3
Size 02
Cat. No.
Size 3
Cat. No.
Size 4
Cat. No.
Size 5
Cat. No.
Size 69
Cat. No.
1493-N15
1493-N15
1493-N16
1493-N16
1493-N17
1493-N17
1493-N20
1493-N15
1493-N16
1493-N17
1401-N4
Converts combination starter enclosure F to enclosure code D or J with Door Safety Hardware.
Standard on bolted Type 3R, 7 & 9.
The breather-drain combination can be in enclosure top as a breather or bottom as a drain. Specify (2) when both functions are required.
Unilock suitable for Types 7 & 9 or Types 3R, 7 & 9 with the addition of a drain or a breather and drain.
For bulletins 512513 only.
1-103
Bulletin_500Line_b.qxd
05/02/2004
17:09
Page 1-104
NEMA
Size
Cat. No.
02
1401-N41
13
1401-N42
13
1401-N43
24
1401-N44
35
1401-N45
45
1401-N46
1401-N50
02
1401-N51
13
1401-N52
24
1401-N53
35
1401-N54
56
1401-N55
02
13
1401-N70
24
1401-N71
35
1401-N72
45
1401-N73
05
1495-N8
05
1495-N9
03
4
5
1495-N56
1495-N57
1495-N58
1495-N61
1 N.C.
1-104
Bulletin_500Line_b.qxd
05/02/2004
17:09
Page 1-105
NEMA Size
Cat. No.
01
1401-N60
01
1401-N61
01
1401-N62
12
1401-N63
13
1401-N64
24
1401-N65
34
1401-N66
1401-N68
1401-N69
1495-N8
05
45
05
1495-N9
02
02
1495-N14
1495-N15
1495-N16
34
45
05
4
34
45
1495-N21
1495-N22
1495-N23
1495-N21
1495-N22
1-105
Bulletin_500Line_b.qxd
05/02/2004
17:09
Page 1-106
Enclosure Type
NEMA
Size
599-PM1
1 (hinged), 3R, 3R/4/12, 4/4X (stainless)
07
3-phase, 480V AC
(Time Mark Model A258B)
Terminal Block
Panel Mount (6 point)
Timing Relays
120V AC, ON Delay 8-pin socket
(Cat. No. 700-HN125) required
0.110 s
120V AC, ON Delay 8-pin socket
(Cat. No. 700-HN125) required
1.0180 s
120V AC, Off-Delay 11-pin socket
(Cat. No. 700-HN126) required
0.110 s
120V AC, OFF Delay 11-pin socket
(Cat. No. 700-HN126) required
1.0180 s
Control Relays
DPDT
2-pole
2 Form C
Single AgNi Contact
3PDT
3-pole
3 Form C
Single AgNi Contact
Cat. No.
599-PM2
07
07
1492-HC6
700-HT12AA1
700-HT12BA1
07
700-HT22AA1
07
700-HT22BA1
07
700-HA32A1
07
700-HA33A1
07
700-HN125
07
700-HN126
Relay Sockets
8-pin socket
1 (hinged), 3R, 3R/4/12, 4/4X (stainless)
11-pin socket
For combination starters only.
3-Phase Power Monitor Kit includes the time mark phase monitor and socket.
Up to two 6-point terminal blocks may be added to each combination starter.
1-106
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-107
NEMA Specifications
NEMA Non-Combination and Combination Contactors/Starters
Electrical Ratings
NEMA
Size
Load
Voltage
(V)
Continuous
Current
(Amps.)
(A)
Service
Limit
Current
Amps.)
(A)
Maximum HP
Rating
(Nonplugging and
Nonjogging Duty)
1
3
Maximum HP
Rating (Plugging
and Jogging Duty)
1
3
Transformer
Primary Switching
kVa Rating
(Inrush Current
< = 20 times
Continuous
Current)
1
3
Maximum
Circuit
Transformer Primary
Closing
Switching kVa
Inrush
Rating
Current
(Inrush Current = 20 Capacitor (A) Peak
to 40 times
Switching Including
Continuous Current) kVAR
Offset
1
3
3
3
11
1/3
1-1/2
1-1/2
1-1/2
2
2
1/4
1/2
1
1
1
1-1/2
1-1/2
87
21
3
3
5
5
5
1/2
1-1/2
1-1/2
1-1/2
2
2
0.6
1.2
2.4
3
1.8
2.1
4.2
5.2
0.3
0.6
1.2
1.5
0.9
1
2.1
2.6
140
7-1/2
7-1/2
10
10
10
3
3
5
5
5
1.2
2.4
4.9
6.2
3.6
4.3
8.5
11
0.6
1.2
2.5
3.1
1.8
2.1
4.3
5.3
13.5
17
288
00
115
200
230
380
460
575
115
200
230
380
460
575
115
200
230
380
460
575
27
32
1P
115
230
36
42
3
5
1-1/2
3
115
200
230
380
460
575
52
7-1/2
10
15
25
25
25
7-1/2
10
15
15
15
2.1
4.1
8.3
10
6.3
7.2
14
18
2.1
4.2
5.2
3.1
3.6
7.2
8.9
12
25
31
483
115
200
230
380
460
575
104
7-1/2
15
25
30
50
50
50
7-1/2
15
15
20
30
30
30
4.1
8.1
16
20
12
14
28
35
4.1
8.1
10
6.1
7.0
14
18
27
53
67
947
115
200
230
380
460
575
156
40
50
75
100
100
25
30
50
60
60
6.8
14
27
34
20
23
47
59
3.4
6.8
14
17
10
12
23
29
40
80
100
1581
115
200
230
380
460
575
311
75
100
150
200
200
60
75
125
150
150
14
27
54
68
41
47
94
117
6.8
14
27
34
20
24
47
59
80
160
200
3163
115
200
230
380
460
575
540
621
150
200
300
400
400
125
150
250
300
300
27
54
108
135
81
94
188
234
14
27
54
68
41
47
94
117
160
320
400
6326
230
460
575
810
932
300
600
600
240
480
600
9470
230
460
575
1215
1400
450
900
900
360
720
900
14205
230
460
575
2250
2590
800
1600
1600
665
1325
1670
25380
18
45
90
135
270
Service-Limit Current Ratings The service-limit current ratings shown represent the maximum rms current, in amperes, which the controller shall be
permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by
testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices used shall not
exceed the service-limit current rating of the controller.
Plugging or Jogging Service The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current
encountered in rapid motor reversal in excess of five openings or closings per minute and shall not be more than ten in a ten minute period.
If maximum available current (at capacitor terminals) is greater than 3,000 amperes, consult your local Allen-Bradley distributor or NEMA ICS-2 Standard.
1-107
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-108
NEMA Specifications
NEMA Non-Combination and Combination Contactors/Starters
Mechanical Ratings
NEMA
Size
0
1
1P
2
3
4
5
6
7
8
9
00
Mechanical Life
(Millions of Operations)
10
10
10
10
5
5
5
5
10
Maximum Number of
Auxiliary Contacts
8
8
8
8
8
8
8
4
8
8
8
5
Construction
Contact Material
NEMA
Size
0
1
1P
2
3
4
5
6
7
8
9
00
Power
Contacts
Auxiliary
Contacts
Type of Power
Terminal
Saddle or Wire
Clamps
Pressure Terminals
Silver Alloy
Silver
Required Torque on
Power Terminal Wire
Clamps and Pressure
Connectors or Lugs
20 lbin
20 lbin
20 lbin
45 lbin
150 lbin
275 lbin
375 lbin
Requirements
for Sizing of Wire
Pressure Terminals
9 lbin
Environmental
NEMA
Size
0
1
1P
2
3
4
5
6
7
8
9
00
1-108
Altitude
Corrosion-Resistance
Operating Position
Vertical
(provided condensation
is prevented)
Vertical
Horizontal
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-109
NEMA Specifications
NEMA Combination Starters and Contactors
Short Circiuit Rating
Combination Contactors and Starters with Disconnect Switch: Bulletin 502, 506, 512, 522E, 522F, 522G and 1232X
Available Short Circuit Amperes RMS
NEMA Size
Fuse Type
Symmetrical (A)
Maximum Voltage (V)
03
45
05
6
7
H, K
5000
H, K
10000
J, R
100000
J, R, L
18000
L
18000
Combination Lighting Contactors with Disconnect Switch: Bulletin 502L
Fuse Type
600
20100
H, K
5000
200300
H, K
10000
600
20300
J, R
100000
Combination Contactors and Starters with Circuit Breaker: Bulletin 503, 507, 513, 523E, 523F, 523G and 1233X
Enclosure Type
1, 3R, 3R/4/12, 4/4X (stainless)
4/4X (non-metallic)
Unilock 3R, 7 & 9
Bolted 3R, 7 & 9
1, 3R, 3R/4/12, 4/4X (stainless)
4/4X (non-metallic)
4/4X (non-metallic)
Unilock 3R, 7 & 9
Unilock 3R, 7 & 9
Bolted 3R, 7 & 9
3R, 3R/4/12
NEMA Size
05
65000
05
22000
05
65000
02
65000
05
25000
03
5000
45
10000
03
5000
45
10000
02
5000
67
10000
Combination Lighting Contactors with Circuit Breaker: Bulletin 503L
Enclosure Type
20300
20300
20300
20300
20300
20100
20300
20100
20300
20300
65000
22000
65000
65000
25000
5000
10000
5000
10000
5000
480
600
480
600
1-109
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-110
NEMA Specifications
NEMA Non-Combination and Combination Contactors/Starters
AC Coil Data
6
7
8
9
NEMA Size
00
0
1 & 1P
2 (23 poles)
2 (45 poles)
3 (23 poles)
3 (45 poles)
4 (23 poles)
4 (45 poles)
5 (Series L)
6
(Interposing relay)
7
(Interposing relay)
8
(Interposing relay)
9
(Interposing relay)
85110%
125 Volts DC
0.55 Amperes
P300
1.1 Amperes
(Requires 2 Contacts in Series)
250 Volts DC
600 Volts DC
0.55 Amperes
(Requires 2 Contacts in Series)
This rating is for the size 6 contactor coil only. All starters are shipped with an interposing relay as standard.
Size 7 starters are shipped with a 250 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor
coil.
Size 8 starters are shipped with a 350 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor
coil.
Size 9 starters are shipped with a 750 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor
coil.
1-110
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-111
NEMA Specifications
NEMA Non-Combination and Combination Contactors/Starters
Load-Life Curves
Utilization Categories
Category
Typical Duty
AC3
Starting of squirrel cage motors and switching off only after the motor is up to speed
AC4
1-111
Bulletin_500Line_c.qxd
05/02/2004
17:17
Page 1-112
NEMA Specifications
NEMA Non-Combination and Combination Contactors/Starters
Full Load Currents of 3-Phase, 60 Hertz AC Induction Motors
The full load currents listed below are average values for horsepower rated motors of several manufacturers at the more common rated
voltages and speeds. These average values, along with the similar values listed in the U.S. National Electrical Code (NEC), should be used
only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the nameplate, may vary
considerably from the listed value depending on the specific motor design.
ATTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running
Overcurrent Protection.
HP
1/4
1/3
1/2
3/4
1-1/2
7-1/2
10
15
20
25
30
40
RPM
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
600
3600
1800
1200
900
600
3600
1800
1200
900
600
3600
1800
1200
900
600
208V
1.20
1.39
1.62
1.48
1.69
1.89
2.08
2.54
2.89
2.89
3.47
3.81
3.51
4.25
4.60
5.04
5.80
6.49
6.51
7.18
8.20
9.24
10.4
11.8
15.7
15.9
18.6
22.1
25.0
26.6
29.7
31.5
32.9
43.0
46.7
49.1
59.2
59.6
61.7
70.9
74.7
76.0
85.7
88.2
91.6
111
117
119
240V
1.04
1.20
1.40
1.28
1.46
1.64
1.80
2.20
2.50
2.50
3.00
3.30
3.04
3.68
3.98
4.36
5.02
5.62
5.64
6.22
7.10
8.00
9.04
10.1
13.6
13.8
16.1
19.1
21.7
23.1
25.7
27.3
28.4
37.2
40.4
42.5
51.3
51.6
53.4
61.4
64.7
65.8
74.2
76.4
79.3
96.0
102
103
0.51
0.64
0.58
0.73
0.66
0.82
0.72
0.90
0.88
0.88
1.00
1.00
1.00
1.25
1.20
1.50
1.32
1.65
1.22
1.52
1.47
1.84
1.59
1.99
1.74
2.18
2.01
2.51
2.25
2.81
2.26
2.82
2.49
3.11
2.84
3.55
3.20
4.00
3.62
4.52
4.03
5.04
5.44
6.80
5.50
6.88
6.46
8.07
7.66
9.57
8.66
10.8
9.22
11.5
10.3
12.9
10.9
13.7
11.4
14.2
14.9
18.6
16.2
20.2
17.0
21.3
20.5
25.6
20.6
25.8
21.4
26.7
24.6
30.7
25.9
32.3
26.3
32.9
29.7
37.1
30.5
38.3
31.7
39.7
38.4
48.0
40.6
50.8
41.4
51.7
1-112
2200V
5.2
5.3
5.4
5.8
6.4
6.3
6.5
6.7
6.9
8.1
7.8
8.0
8.2
9.3
10.0
10.3
10.6
11.5
2200V
2.9
3.0
3.1
3.2
3.5
3.4
3.6
3.7
3.8
4.4
4.3
4.4
4.5
5.0
5.5
5.7
5.8
6.3
HP
50
60
75
100
125
150
200
250
300
350
400
450
500
RPM
3600
1800
1200
900
600
3600
1800
1200
900
600
3600
1800
1200
900
600
3600
1800
1200
900
600
450
3600
1800
1200
900
720
600
450
3600
1800
1200
900
720
600
450
3600
1800
1200
900
720
600
450
3600
1800
1200
900
720
600
450
360
3600
1800
1200
900
720
600
450
360
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
208V
141
144
147
165
172
173
204
211
215
267
276
281
333
340
347
397
404
414
524
531
538
642
658
682
774
790
804
240V
122
125
127
143
149
150
177
183
186
231
239
243
288
294
300
344
350
358
454
460
466
556
570
590
670
684
696
748
762
774
874
892
902
972
992
1004
1074
1096
1108
57.3
71.6
59.4
74.3
59.9
74.9
70.8
88.5
73.1
91.4
74.5
93.1
92.6
116
95.5
119
97.2
122
115
144
118
147
120
150
138
172
140
175
143
179
182
227
184
230
186
233
222
278
228
285
236
295
258
335
274
342
278
348
299
374
305
381
310
387
350
437
357
446
361
451
389
486
397
496
402
502
430
537
438
548
443
554
2200V
12.3
12.4
13.1
14.2
14.6
14.9
15.4
16.7
18.0
18.2
19.0
21.0
23.6
24.2
24.8
26.4
29.8
29.2
29.9
30.9
31.3
32.8
36.0
34.8
35.5
37.0
37.0
38.8
42.0
46.7
47.0
49.4
49.0
50.9
53.7
57.5
58.5
61.5
61.5
61.0
65.3
70.0
69.0
70.0
73.5
72.3
76.0
82.8
2200V
6.8
6.8
7.2
7.8
8.0
8.2
8.5
9.2
9.9
10.0
10.5
11.6
13.0
13.3
13.6
14.5
16.4
16.1
16.4
17.0
17.2
18.0
19.8
19.1
19.5
20.4
20.4
21.3
23.1
25.7
25.9
27.2
27.0
28.0
29.5
31.6
32.2
33.8
33.8
33.6
35.9
38.5
38.0
38.5
40.4
39.6
41.8
45.5
Bulletin_500Line_d.qxd
05/02/2004
17:25
Page 1-113
Approximate Dimensions
NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Note: Top mounting hole on Size 00 is 1/4 in (6.35) to the left of centerline on Open Type. Mounting screws: 3 - #10 for sizes 02; 1/4 - #20
or 5/16 - #18 for sizes 35.
NEMA
Size
00
5/10A
01
15/20A
30A
2
60A
3
100A
4
200A
5
300A
Number of
Switching Poles
Bul. 500
Bul.
500F-500FL
500L-500LP
1-2-3
23
23
23
23
23
23
23
23
23
23
23
A
Width
1-25/32
(45)
3-9/16
(90.5)
4-3/8
(111)
4-15/16
(125)
3-15/16
(100)
4-31/32
(126)
5-1/2
(140)
6-1/8
(155.5)
7-15/16
(201.6)
8-13/16
(223.8)
7
(178)
9-1/16
(230.2)
10-7/16
(265.1)
7
(178)
E
1-25/64
(35)
6
(152)
4-15/32
(113)
5-1/2
(140)
2-3/4
(70)
6-27/32
(173)
4-23/32
(120)
6-5/16
(160)
3-5/32
(80)
10-3/64
(255)
6-19/32
(167.4)
8-21/32
(220)
5-33/64
(140)
12-11/64
(309)
7-13/16
(198.4)
9-27/32
(250)
6-5/16
(160)
13-25/64
(340)
8-17/32
(217)
9-27/32
(250)
6-5/16
(160)
Approximate
Shipping
Weight in
lbs (kg)
1
(0.45)
3
(1.4)
3-1/2
(1.6)
4-3/4
(2.2)
4
(1.8)
4-3/4
(2.2)
6-1/4
(2.8)
14.5
(6.5)
16
(7.25)
18
(8)
22
(10)
25.5
(11.5)
28.5
(13)
24
(10.9)
1-113
Bulletin_500Line_d.qxd
05/02/2004
17:25
Page 1-114
Approximate Dimensions
NEMA Reversing Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 505 Full Voltage Reversing Starters with Eutectic Alloy Overload Relay
NEMA
Size
Style
00
01
2
3
4
5
With
Eutectic
Alloy
Overload
Protection
6
7
8
A
Width
4-7/8
(124)
8
(203)
9-1/16
(230)
12-7/8
(327)
14-27/32
(377)
14-27/32
(377)
23-13/32
(594.5)
31-1/2
(800)
35-1/4
(896)
B
Height
6-9/16
(167)
9-5/32
(233)
10-11/32
(263)
12-29/64
(316)
14-5/8
(371)
17-55/64
(453)
25-5/64
(637)
32-13/16
(833.4)
36-7/8
(937)
4-7/8
(124)
8
(203)
9-1/16
(230)
12-7/8
(327)
14-27/32
(377)
14-27/32
(377)
23-13/32
(594.5)
31-1/2
(800)
35-1/4
(896)
4-5/16
(110)
7-19/32
(193)
8-3/8
(213)
10-21/32
(271)
12-23/32
(323)
12-23/32
(323)
17-1/16
(433)
32-13/16
(833.4)
36-7/8
(937)
9
00
01
2
3
4
5
Without
Overload
Protection
6
7
8
9
(268.5)
12-9/32
(311.9)
12-9/32
(311.9)
For dimensions, consult factory.
2-3/16
3-3/4
4-3/8
(55.6)
(95.3)
(111)
7-3/32
7-3/32
(180)
(180)
7-7/8
7-7/8
(200)
(200)
9-27/32
11-13/16
(250)
(300)
11-13/16
13-25/32
(300)
(350)
11-13/16
13-25/32
(300)
(350)
11-13/16
(300)
13-25/32
(350)
13-25/32
(350)
11-13/16
(300)
13-25/32
(350)
13-25/32
(350)
4-5/8
(117)
4-29/32
(125)
6-55/64
(174)
8-5/64
(205)
8-13/16
(224)
11-27/64
(290)
G
Depth
1-114
Approx.
Shipping
Weight in
lbs (kg)
4
(1.8)
10
(4.5)
12-3/4
(5.8)
34
(15.5)
52
(24)
65
(29.5)
4-5/8
(117)
4-29/32
(125)
6-55/64
(174)
8-5/64
(205)
8-13/16
(224)
11-27/64
(290)
11-11/32
(288.1)
11-13/16
(300)
2-3/4
(1.2)
8-3/4
(4)
11
(5)
30
(13.5)
47
(21.3)
47
(21.3)
Bulletin_500Line_d.qxd
05/02/2004
17:25
Page 1-115
Approximate Dimensions
NEMA Reversing Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 505V Full Voltage Reversing Starters with Solid State Overload Relay
Overload
Relay
Solid-State
01
Solid-State
Solid-State
2
Solid-State
Solid-State
3
Solid-State
Solid-State
4
Solid-State
Solid-State
5
Solid-State
A
Width
5-11/16
(144)
5-11/16
(144)
6-1/8
(156)
6-1/8
(156)
7-17/32
(192)
7-17/32
(192)
8-5/32
(208)
8-5/32
(208)
8-7/16
(215)
8-7/16
(215)
B
Height
14-11/16
(373)
16-27/32
(428)
17-1/16
(434)
18-7/8
(479)
25-1/8
(639)
27-13/32
(696)
29-3/32
(739)
29-3/32
(739)
37-7/8
(962)
37-7/8
(962)
C
Depth
4-31/32
(126)
4-31/32
(126)
5-7/32
(133)
5-7/32
(133)
7-19/32
(193)
7-19/32
(193)
8-13/16
(224)
8-13/16
(224)
9-17/32
(242)
9-17/32
(242)
D
13-25/32
(350)
13-25/32
(350)
15-3/4
(400)
15-3/4
(400)
21-21/32
(550)
21-21/32
(550)
25-19/32
(650)
25-19/32
(650)
36-31/32
(939)
36-31/32
(939)
E
4-5/16
(109)
4-11/32
(110)
4-23/32
(120)
4-23/32
(120)
5-29/32
(150)
5-29/32
(150)
6-23/32
(171)
6-23/32
(171)
6-11/16
(170)
6-11/16
(170)
F
Relay Reset
Depth
5
(127)
5-9/32
(134)
5
(127)
5-9/32
(134)
7-1/16
(179)
7-5/32
(182)
7-15/32
(190)
8-11/16
(221)
9-9/32
(236)
9-29/32
(252)
G
1/16
(1.6)
1/16
(1.6)
1/4
(6.4)
1/4
(6.4)
1-3/32
(28)
1-3/32
(28)
2
(51)
2-5/32
(55)
2
(51)
2
(51)
Approx.
Shipping
Weight in
lbs (kg)
0-11.5 (5.2)
1-12.2 (5.5)
14.5 (6.6)
57.4 (26.0)
86.0 (39.0)
112 (50.8)
1-115
Bulletin_500Line_d.qxd
05/02/2004
17:25
Page 1-116
Approximate Dimensions
NEMA Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 509 Full Voltage Starters with Eutectic Alloy and Solid-State Overload Relay
Size 09
NEMA
Size
00
01
2
3
4
5
6
7
8
9
A
Width
3-9/16 (90.5)
3-15/16 (100)
6-11/64 (157)
7 (178)
7-3/8 (187)
13-1/4 (337)
16-1/2 (419)
21-1/2 (546)
34 (864)
7-5/8 (194)
4-1/2 (114)
7-3/32 (180)
9-5/32 (233)
4-1/2 (114)
8-21/32 (220)
12-29/64 (316)
6-1/16 (154)
8-21/32 (220)
14-21/32 (372)
7-13/16 (198)
9-27/32 (250)
16-7/6 (429)
8-17/32 (217)
14-32/32 (380)
25-3/32 (637)
11-7/16 (291)
17-23/32 (450)
30-27/32 (783)
12-9/32 (312)
18-5/16 (465)
39-1/2 (1003)
15-19/32 (396)
22-5/8 (575)
53-11/16 (1364)
28 (711)
1-116
2-3/4 (70)
3-5/32 (80)
5-33/64 (140)
6-5/16 (160)
6-5/16 (160)
11-13/16 (300)
15 (381)
20 (508)
Approx. Shipping
Weight in
lbs (kg)
0.9 (0.4)
4-1/4 (1.9)
5-3/4 (2.6)
15 (6.8)
23-1/5 (10.6)
35 (15.9)
160 (72)
247 (112)
370 (168)
Bulletin_500Line_d.qxd
05/02/2004
17:25
Page 1-117
Approximate Dimensions
NEMA Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 509 Full Voltage Starters with solid state OverloadRelay
Overload
Relay
Solid-State
01
Solid-State
Solid-State
2
Solid-State
Solid-State
3
Solid-State
Solid-State
4
Solid-State
Solid-State
5
Solid-State
Solid-State
6
Solid-State
A
Width
3-9/16
(91)
3-9/16
(91)
3-15/16
(100)
3-15/16
(100)
6-1/8
(156)
6-1/8
(156)
7
(178)
7
(178)
7-3/8
(188)
7-3/8
(188)
13-1/4
(337)
13-1/4
(337)
B
Height
7-5/8
(193)
9-25/32
(248)
9-5/32
(233)
10-25/32
(274)
12-7/16
(316)
14-9/16
(370)
14-5/32
(360)
15-13/32
(391)
16-29/32
(429)
16-29/32
(429)
25-3/32
(637)
25-3/32
(637)
C
Depth
4-15/32
(113)
4-15/32
(113)
4-11/16
(119)
4-23/32
(120)
6-19/32
(168)
6-19/32
(168)
7-13/16
(199)
7-13/16
(199)
8-9/16
(217)
8-9/16
(217)
11-13/32
(289)
11-13/32
(289)
D
7-1/16
(180)
9-1/4
(235)
8-5/8
(219)
10-1/4
(260)
8-21/32
(220)
8-21/32
(220)
9-27/32
(250)
9-27/32
(250)
14-31/32
(380)
14-31/32
(380)
17-23/32
(450)
17-23/32
(450)
E
2-3/4
(70)
2-3/4
(70)
3-5/32
(80)
3-5/32
(80)
5-1/2
(140)
5-1/2
(140)
6-5/16
(160)
6-5/16
(160)
6-5/16
(160)
6-5/16
(160)
11-13/16
(300)
11-13/16
(300)
F
Relay
Reset Depth
4-1/2
(114)
4-5/8
(118)
4-1/2
(114)
4-5/8
(118)
6-1/16
(154)
5-61/64
(151)
6-7/16
(164)
7-1/2
(190)
8-9/32
(210)
8-13/16
(223)
10-5/8
(270)
11-7/16
(291)
Approx.
Shipping
Weight in
lbs (kg)
4.3 (1.9)
6.0 (2.7)
16.0 (7.3)
24.6 (11.2)
33.9 (15.4)
116 (52.6)
Note: For Bulletin 509 Size 00, consult your local Allen-Bradley distributor.
1-117
Bulletin_500Line_d.qxd
05/02/2004
17:26
Page 1-118
Approximate Dimensions
NEMA Multi-Speed Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 520E-520F-520G Multi-Speed Starters with Eutectic Alloy Overload Relay
01
2
3
4
5
01
2
3
4
5
A
Width
B
Height
8
(203)
9-1/16
(230)
12-7/8
(327)
14-27/32
(377)
16-13/16
(427)
9-5/32
(233)
10-11/32
(263)
12-29/64
(316)
15-1/64
(381)
17-55/64
(453)
9-5/16
(236.5)
10-1/4
(260.4)
16-1/4
(413)
18-7/32
(463)
18-11/32
(466)
9-5/32
(233)
10-11/32
(263)
12-29/64
(316.3)
14-39/64
(371)
17-55/64
(453)
C
Depth
D
E
2-Speed Separate Winding Bulletin 520E
4-11/16
8-21/32
7-3/32
(119)
(220)
(180)
4-11/16
9-27/32
7-7/8
(119)
(250)
(200)
6-21/64
9-27/32
11-13/16
(161)
(250)
(300)
6-23/32
11-13/16
13-25/32
(171)
(300)
(350)
8-35/64
16-15/16
15-3/4
(217)
(430)
(400)
2-Speed Consequent Pole Bulletin 520F and 520G
4-11/16
(119)
4-11/16
(119)
6-21/64
(161)
6-23/32
(171)
8-35/64
(217)
8-21/32
(220)
9-27/32
(250)
9-27/32
(250)
11-13/16
(300)
16-15/16
(430)
7-3/32
(180)
7-7/8
(200)
13-25/32
(350)
15-3/4
(400)
15-3/4
(400)
1-118
F
Relay
Reset Depth
11-13/16
(300)
13-25/32
(350)
15-3/4
(400)
13-25/32
(350)
15-3/4
(400)
15-3/4
(400)
Approx.
Shipping
Weight
in lbs (kg)
4-5/8
(117)
4-29/32
(125)
6-55/64
(174)
8-5/64
(205)
8-13/16
(224)
11-1/4
(5.1)
13-3/4
(6.2)
34
(15.3)
54
(24.3)
82
(36.9)
4-5/8
(117)
4-29/32
(125)
6-55/64
(174)
8-5/64
(205)
8-13/16
(224)
12
(5.4)
15-1/4
(7)
44
(19.8)
63
(28.4)
85
(38.6)
Bulletin_500Line_d.qxd
05/02/2004
17:26
Page 1-119
Approximate Dimensions
NEMA Multi-Speed Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type Enclosure for Bulletin 520E-520F-520G Multi-Speed Starters with Solid State Overload Relay
Overload
Relay
Solid-State
01
Solid-State
Solid-State
2
Solid-State
Solid-State
3
Solid-State
Solid-State
4
Solid-State
Solid-State
5
Solid-State
Solid-State
6
Solid-State
Solid-State
01
Solid-State
Solid-State
2
Solid-State
Solid-State
3
Solid-State
Solid-State
4
Solid-State
Solid-State
5
Solid-State
A Width
8
(203)
8
(203)
9-1/16
(230)
9-1/16
(230)
12-7/8
(327)
12-7/8
(327)
14-27/32
(377)
14-27/32
(377)
16-13/16
(427)
16-13/16
(427)
23-13/32
(595)
23-13/32
(595)
9-5/16
(237)
9-5/16
(237)
10-1/4
(260)
10-1/4
(260)
16-1/4
(413)
16-1/4
(413)
18-7/32
(463)
18-3/4
(476)
18-11/32
(466)
18-11/32
(466)
B Height
C Depth
D
E
2-Speed Separate Winding Bulletin 520E
9-5/32
4-5/8
8-21/32
7-3/32
(233)
(118)
(220)
(180)
11-11/32
4-5/8
10-27/32
7-3/32
(288)
(118)
(276)
(180)
10-11/32
4-29/32
9-27/32
7-7/8
(263)
(125)
(250)
(200)
12-5/32
4-29/32
11-21/32
7-7/8
(309)
(125)
(296)
(200)
12-13/32
6-7/8
9-27/32
11-13/16
(315)
(175)
(250)
(300)
14-9/16
6-55/64
9-27/32
11-13/16
(370)
(174)
(250)
(300)
14-7/16
8-3/32
11-13/16
13-25/32
(365)
(205)
(300)
(350)
15-21/32
8-3/32
11-13/16
13-25/32
(397)
(205)
(300)
(350)
17-7/8
8-13/16
16-15/16
15-3/4
(454)
(224)
(430)
(400)
17-7/8
8-13/16
16-15/16
15-3/4
(454)
(224)
(430)
(400)
25-3/32
11-27/64
17-23/32
21-31/32
(637)
(290)
(450)
(558)
25-3/32
11-27/64
17-23/32
21-31/32
(637)
(290)
(450)
(558)
2-Speed Consequent Pole Bulletin 520F and 520G
9-5/32
(233)
11-11/32
(288)
10-11/32
(263)
12
(305)
12-3/4
(324)
14-7/8
(378)
14-27/32
(377)
16-1/16
(408)
17-7/8
(454)
17-7/8
(454)
4-5/8
(117)
4-5/8
(117)
4-29/32
(125)
4-29/32
(125)
6-7/8
(175)
6-7/8
(175)
8-3/32
(205)
8-3/32
(205)
8-13/16
(224)
8-13/16
(224)
8-21/32
(220)
10-27/32
(275)
9-27/32
(250)
11-1/2
(292)
9-27/32
(250)
9-27/32
(250)
11-13/16
(300)
11-13/16
(300)
16-15/16
(430)
16-15/16
(430)
7-3/32
(180)
7-3/32
(180)
7-7/8
(200)
7-7/8
(200)
13-25/32
(350)
13-25/32
(350)
15-3/4
(400)
15-3/4
(400)
15-3/4
(400)
15-3/4
(400)
F Relay
Reset Depth
4-11/16
(118)
4-31/32
(126)
4-11/16
(118)
4-31/32
(126)
6-11/32
(161)
6-17/64
(158)
6-23/32
(171)
7-3/4
(196.9)
8-9/16
(217)
9-3/16
(233)
10-37/64
(269)
11-9/16
(294)
3-3/16
(81)
3-3/16
(81)
4-11/32
(110)
4-11/32
(110)
4-11/16
(118)
4-31/32
(126)
4-11/16
(118)
4-31/32
(126)
6-11/32
(161)
6-15/32
(164)
6-3/4
(172)
7-15/16
(202)
8-9/16
(217)
9-3/16
(233)
3-9/16
(91)
3-9/16
(91)
4-3/4
(121)
4-3/4
(121)
Approx.
Shipping
Weight in
lbs (kg)
11.3 (5.1)
14.9 (6.8)
35.6 (16.1)
61.0 (27.7)
93.5 (42.4)
254 (115)
12.0 (5.4)
15.6 (7.1)
45.0 (20.4)
73.0 (33.1)
131 (59.4)
1-119
Bulletin_500Line_d.qxd
05/02/2004
17:26
Page 1-120
Approximate Dimensions
NEMA Multi-Speed Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 520VE-520VF-520VG Multi-Speed Starters with Eutectic Alloy Overload Relay
NEMA Size
01
2
3
4
5
01
2
3
4
5
A
Width
B
Height
C
Depth
5-11/16
(144.5)
6-1/8
(155.6)
7-17/32
(191.3)
8-5/16
(211.2)
8-7/16
(214.4)
17-9/64
(435.4)
20-37/64
(522.7)
30-5/16
(769.9)
35-1/4
(895.4)
42-11/64
(1071.1)
4-15/16
(125.4)
4-5/8
(117.5)
7-1/4
(184.1)
8-23/64
(212.3)
9-17/32
(242.1)
6-3/64
(164.7)
6-29/32
(175.4)
9-1/8
(231.8)
10-9/32
(261.1)
11-29/32
(302.4)
17-1/2
(444.5)
20-37/64
(522.7)
30-5/16
(777.9)
35-1/4
(895.4)
42-11/64
(1071.1)
4-15/16
(125.4)
4-5/8
(117.5)
7-1/4
(184.1)
8-23/64
(212.3)
9-17/32
(242.1)
1-120
Approx.
Shipping
Weight in
lbs (kg)
1-13/16
(46)
2-27/32
(72.2)
3-41/64
(92.5)
3-63/64
(101.2)
3-23/32
(94.4)
4-21/64
(109.9)
4-23/32
(119.8)
5-29/32
(150)
6-11/16
(169.9)
6-11/16
(170)
1/16
(1.6)
1/4
(6.4)
1-3/32
(27.8)
1-1/2
(38.1)
3
(76.2)
5.4
(12)
6.8
(15)
18.1
(40)
60-1/2
(27.4)
2-63/64
(75.8)
31-19/64
(83.7)
5-23/64
(136.2)
5-61/64
(151.2)
5-11/16
(144.4)
5-1/8
(130.2)
5-33/64
(140.1)
7-31/64
(190.1)
8-21/32
(219.9)
8-21/32
(220)
33/64
(13.1)
23/32
(18.1)
2-1/8
(54)
3-7/32
(81.8)
4
(101.6)
13
(5.9)
16
(7.3)
45-1/2
(20.7)
72-1/2
(32.9)
Bulletin_500Line_d.qxd
05/02/2004
17:26
Page 1-121
Approximate Dimensions
NEMA Multi-Speed Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 520VE-520VF-520VG Multi-Speed Starters with Solid State Overload Relay
Note: The typical drawing above shows 3-point mounting. Sizes 3 through 5 have 4-point mounting holes at each corner of the mounting
plate.
2-Speed Separate Winding Bulletin 520VE
Dimensions in Inches (Millimeters)
NEMA
Size
Overload
Relay
Solid State
01
Solid State
Solid State
2
Solid State
Solid State
3
Solid State
Solid State
4
Solid State
Solid State
5
Solid State
A
Width
5-11/16
(145)
5-11/16
(145)
6-1/8
(156)
6-1/8
(156)
7-17/32
(192)
7-17/32
(192)
8-5/16
(208)
8-5/16
(208)
8-7/16
(215)
8-7/16
(215)
B
Height
17-1/4
(438)
21-1/2
(546)
20-9/16
(522)
23-13/16
(605)
31-1/16
(789)
35-9/16
(903)
35
(889)
37-23/32
(958)
42-3/16
(1072)
42-3/16
(1072)
C
Depth
4-15/16
(126)
4-15/16
(126)
4-5/8
(118)
4-5/8
(118)
7-19/32
(193)
7-19/32
(193)
8-13/16
(224)
8-13/16
(224)
9-17/32
(242)
9-17/32
(242)
D
15-3/4
(400)
15-3/4
(400)
19-11/16
(500)
19-11/16
(500)
27-9/16
(700)
34-23/32
(882)
31-1/2
(800)
36-13/16
(935)
41-9/32
(1049)
41-9/32
(1049)
E
4-5/16
(109)
4-11/32
(110)
4-23/32
(120)
4-23/32
(120)
5-29/32
(150)
5-29/32
(150)
6-11/16
(170)
6-11/16
(170)
6-11/16
(170)
6-11/16
(170)
F
Relay Reset
Depth
5
(127)
5-9/32
(134)
4-15/16
(125.5)
5-9/32
(134)
7-1/16
(179.4)
7-5/32
(182)
7-15/32
(190)
8-23/32
(222)
9-9/32
(236)
9-9/32
(236)
G
1/16
(1.6)
1/16
(1.6)
1/4
(6.4)
1/4
(6.4)
1-3/32
(28)
1-3/32
(28)
1-1/2
(38)
1-1/8
(29)
3
(76)
3
(76)
Approx.
Shipping
Weight in
lbs (kg)
12.7 (5.3)
16.0 (7.3)
74.8 (33.9)
98.0 (44.4)
113 (51.2)
1-121
Bulletin_500Line_d.qxd
05/02/2004
17:26
Page 1-122
Approximate Dimensions
NEMA Multi-Speed Starters
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Open Type without Enclosure for Bulletin 520VE-520VF-520VG Multi-Speed Starters with Solid State Overload Relay,
Continued
Overload
Relay
Solid-State
01
Solid-State
Solid-State
2
Solid-State
Solid-State
3
Solid-State
Solid-State
4
Solid-State
Solid-State
5
Solid-State
A
Width
6-5/8
(168)
7
(177)
6-29/32
(176)
6-29/32
(176)
9-1/8
(232)
10-3/32
(256)
11-23/32
(298)
11-23/32
(298)
11-29/32
(303)
11-29/32
(303)
B
Height
17-1/2
(444.5)
22-11/16
(576)
20-19/32
(523)
23-13/16
(605)
31-1/16
(789)
35-9/16
(903)
35
(889)
37-23/32
(958)
42-3/16
(1072)
42-3/16
(1072)
C
Depth
4-15/16
(126)
4-15/16
(126)
4-5/8
(118)
4-5/8
(118)
7-19/32
(193)
7-19/32
(193)
8-13/16
(224)
8-13/16
(224)
9-17/32
(242)
9-17/32
(242)
D
15-3/4
(146)
15-3/4
(146)
19-11/16
(500)
19-11/16
(500)
27-9/16
(700)
34-23/32
(882)
31-1/2
(800)
36-13/16
(935)
41-9/32
(1049)
41-9/32
(1049)
E
5-1/8
(130)
5-1/8
(130)
5-17/32
(141)
5-17/32
(141)
7-1/2
(191)
7-1/2
(191)
8-21/32
(220)
8-21/32
(220)
8-21/32
(220)
8-21/32
(220)
1-122
F
Relay Reset
Depth
5
(127)
5-9/32
(134)
4-5/16
(110)
5-9/32
(134)
7-1/16
(179)
7-5/32
(182)
7-15/32
(190)
8-23/32
(222)
9-9/32
(236)
9-9/32
(236)
G
1/2
(13)
17/32
(13)
3/4
19)
3/4
19)
2-1/8
(54)
1-25/32
(29)
3-7/32
(82)
1-25/32
(29)
4
(102)
4
(102)
Approx.
Shipping
Weight in
lbs (kg)
12.7 (5.8)
16.0 (7.3)
74.8 (33.9)
98.0 (44.4)
113 (51.2)
Bulletin_500Line_e.qxd
05/02/2004
17:39
Page 1-123
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
NEMA
Size
00
5/10A
01
15/20A, 30A
2
60A
3 2-3-Pole
100A 2-3-Pole
4 2-3-Pole
200A 2-3-Pole
5 2-3-Pole
300A 2-3-Pole
A
Width
4-7/8
(124)
6-13/16
(173)
7-5/16
(186)
10-1/4
(260.4)
11-5/8
(295.3)
13-3/8
(339.7)
B
Height
7-11/16
(195)
10-5/8
(270.3)
13-3/4
(349.3)
20-3/16
(513)
23-1/2
(597)
29-3/4
(756)
E
1-7/8
(48)
2-3/8
(60.5)
2-5/8
(66.5)
3-3/4
(95.2)
4
(102)
5
(127)
F
7/32
(5.6)
7/32
(5.5)
9/32
(7.1)
11/32
(8.7)
11/32
(8.7)
11/32
(8.7)
Approx. Shipping
Weight in
lbs (kg)
4
(1.8)
6-3/4
(3.1)
9-1/2
(4.3)
27
(12)
40
(18)
NEMA
Size
3 4-5-Pole
100A 4 Pole
4 4-5-Pole
200A 4 Pole
5 4 Pole
300A 4 Pole
A
Width
12-1/8
(308)
14-1/8
(358.8)
21-29/32
(556.4)
B
Height
20-3/16
(513)
26-5/8
(676.3)
41-5/32
(1045.4)
E
4-1/8
(105)
5
(127)
9-1/2
(241.3)
F
11/32
(8.7)
11/32
(8.7)
11/32
(8.7)
Approx. Shipping
Weight in
lbs (kg)
32
(14)
49
(22)
Note: For Types 3R/12, 4/4X, 4X, and Bolted Type 7 & 9 and 3R, 7 & 9 dimensions, consult your local Allen-Bradley distributor.
1-123
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-124
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
3
4
5
Bulletin No.
505
505-520E
505-520E
520F-520G
505-520E
505-520E
520F-520G
505-520E
520F-520G
505-520E
520F-520G
505-520E
520F-520G
A Width
6-13/16 (173)
10-9/16 (268)
B Height
10 (254)
12-1/2 (318)
C Depth
5 (127)
5-31/32 (152)
D
7-1/4 (184)
9-7/8 (251)
E
2-3/4 (69.8)
4-3/8 (111)
9/32 (7.1)
Approx. Shipping
Weight in
lbs (kg)
7-1/2 (3.4)
18 (8.2)
12-1/2 (318)
14-1/8 (359)
6-1/8 (156)
11-1/4 (286)
4-1/2 (114)
9/32 (7.1)
18 (8.2)
11-7/16 (291)
14-9/16 (370)
5-31/32 (152)
11-13/16 (300)
4-1/2 (114)
9/32 (7.1)
21-1/4 (9.6)
21-1/4 (9.6)
13-1/2 (343)
15-5/8 (397)
6-3/8 (162)
13-1/2 (343)
5-1/2 (140)
9/32 (7.1)
15-1/8 (384)
18-21/32 (474)
16-5/8 (422)
21-5/32 (537)
20-3/16 (513)
19-11/32 (491)
27-1/2 (698)
27-17/32 (699)
8-3/16 (208)
8-1/4 (210)
9-5/16 (237)
9-7/16 (240)
16-1/2 (419)
16-1/2 (419)
24 (610)
24 (610)
6 (152)
8 (203)
6-1/4 (159)
8-1/2 (216)
11/32
11/32
11/32
11/32
21-29/32 (556)
41-5/32 (1045)
10-15/32 (265.9)
39 (991)
9-1/2 (241)
11/32 (8.7)
6
7
8
9
(8.7)
(8.7)
(8.7)
(8.7)
53 23.(9)
80 (36)
Type 1 General Purpose Enclosures for Bulletin 509 Full Voltage Starters
A Width
6-9/32 (160)
4-7/8 (124)
6-13/16 (173)
7-5/16 (816)
10-1/4 (260)
13-3/8 (340)
16-1/8 (410)
25-1/4 (641)
B Height
9-3/16 (233)
7-11/16 (195)
10-5/8 (270)
13-3/4 (349)
20-3/16 (513)
29-3/4 (756)
42 (1067)
53-5/8 (1362)
C Depth
4-1/2 (114)
4-5/8 (117)
5-23/32 (145)
5-23/32 (145)
7-15/16 (202)
9-31/32 (253)
10-1/8 (254)
14 (356)
D
6-7/8 (175)
5-5/8 (143)
8-1/4 (210)
10-3/4 (273)
16 (406)
25-3/4 (654)
38 (965)
52-1/4 (1327)
1-124
E
2-1/2 (63.5)
1-7/8 (47.5)
2-3/8 (60.5)
2-5/8 (66.5)
3-3/4 (95.2)
4 (102)
6 (152)
10-1/4 (261)
7/32 (5.5)
9/32 (7.1)
11/32 (8.7)
11/32 (8.7)
11/32 (8.7)
Approx. Shipping
Weight in
lbs (kg)
4-1/4 (1.9)
4 1.(8)
7-1/4 (3.4)
10-1/2 (4.7)
31 (14)
44 (19.8)
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-125
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
A
Width
12-1/8
(308)
13-1/8
(333.4)
18-21/32
(473.9)
21-5/32
(537.4)
B
Height
16-1/16
(408)
17-9/16
(446.1)
21-9/16
(547.7)
28-27/32
(732.6)
C
Depth
6
(152.4)
6-1/4
(158.8)
8-1/8
(206.4)
9-9/32
(235.7)
D
15-1/4
(387.4)
16-3/4
(425.5)
20-11/16
(525.5)
28
(711.2)
E
4-1/2
(114.3)
5
(127)
7-1/2
(190.5)
8-1/2
(215.9)
F
9/32
(7.1)
9/32
(7.1)
11/32
(8.7)
11/32
(8.7)
G
14-1/8
(358.8)
15-5/8
(396.9)
19-11/32
(491.3)
26-21/32
(677.1)
H
3/8
(9.5)
3/8
(9.5)
3/8
(9.5)
3/8
(9.5)
J
7/16
(11.1)
7/16
(11.1)
1/2
(12.7)
1/2
(12.7)
K
3/32
(2.4)
3/32
(2.4)
3/16
(4.8)
3/16
(4.8)
A
Width
8-3/8
(212.7)
8-7/8
(225.4)
12-1/8
(308)
14-1/8
(358.8)
B
Height
12-7/32
(310.4)
15-3/8
(390.5)
22-7/16
(569.9)
28-13/16
(731.8)
C
Depth
5-7/8
(149.2)
5-15/16
(150.8)
7-15/16
(201.6)
9
(228.6)
D
11-15/32
(291.3)
14-5/8
(371.5)
21-9/16
(547.7)
28
(711.2)
E
2-1/2
(63.5)
2-5/8
(66.7)
4-7/16
(112.7)
5-7/16
(138.1)
F
9/32
(7.1)
9/32
(7.1)
11/32
(8.7)
11/32
(8.7)
G
10-3/8
(263.5)
13-1/2
(342.9)
20-3/16
(512.8)
26-5/8
(676.3)
H
7/16
(11.1)
7/16
(11.1)
1/2
(12.7)
1/2
(12.7)
Approx.
Shipping
Weight in
lbs (kg)
13-1/2
(6.1)
18-1/2
(8.4)
35-1/2
(16.1)
59-1/2
(27)
Note: For Type 3R/12 with control transformer dimensions, consult your local Allen-Bradley distributor.
1-125
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-126
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
A
Width
12-1/8
(308)
13-1/8
(333.4)
18-11/16
(474.7)
21-3/16
(538.2)
B
Height
16-7/8
(428.6)
18-7/8
(479.4)
22-11/32
(567.5)
30-15/16
(785.8)
C
Depth
6-15/22
(164.3)
6-9/16
(166.7)
8-1/8
(206.4)
9-1/4
(235)
D
15-1/4
(387.1)
16-3/4
(425.5)
20-11/16
(525.5)
28
(711.2)
E
4-1/2
(114.3)
5
(127)
7-1/2
(190.5)
8-1/2
(215.9)
F
9/32
(7.1)
9/32
(7.1)
11/32
(8.7)
11/32
(8.7)
G
16
(406.4)
17-1/2
(444.5)
21-9/16
(547.7)
28-7/8
(733.4)
H
7/16
(11.1)
7/16
(11.1)
1/2
(12.7)
1/2
(12.7)
J
14-1/8
(358.8)
15-5/8
(396.9)
19-3/8
(492.1)
26-11/16
(677.9)V
K
1-3/8
(34.9)
1-5/8
(41.3)
1-1/2
(38.1)
2-1/8
(54)
L
3/4
(19.1)
1
(25.4)
23/32
(18.3)
1-11/32
(34.2)
M
2-5/32
(54.8)
2-5/32
(54.8)
2-15/32
(62.7)
3-3/16
(81)
A
Width
8-3/8
(212.7)
8-7/8
(225.4)
12-1/8
(308)
14-1/8
(358.8)
B
Height
10-3/8
(263.5)
13-1/2
(342.9)
20-7/32
(513.5)
26-5/8
(676.3)
C
Depth
6-7/32
(157.9)
6-11/32
(161.1)
7-27/32
(199.2)
8-13/16
(223.8)
D
11-15/32
(291.3)
14-5/8
(371.5)
21-9/16
(547.7)
27
(685.8)
E
2-1/2
(63.5)
2-5/8
(66.7)
4-7/16
(112.7)
5-7/16
(138.1)
F
9/32
(7.1)
9/32
(7.1)
11/32
(8.7)
11/32
(8.7)
G
12-7/32
(310.3)
15-3/8
(390.5)
22-7/16
(569.9)
27-7/8
(708)
H
5/16
(7.9)
5/16
(7.9)
5/16
(7.9)
7/32
(5.5)
J
7/16
(11.1)
7/16
(11.1)
1/2
(12.7)
1/2
(12.7)
K
3/32
(2.4)
3/32
(2.4)
1/8
(3.2)
1/8
(3.2)
Note: For Type 4/4X with control transformer and Type 4X dimensions, consult your local Allen-Bradley distributor.
1-126
L
13-1/8
(333.4)
16-3/4
(425.4)
23-7/32
(589.8)
30-7/8
(784.2)
M
1-3/8
(34.9)
1-5/8
(41.3)
1-1/2
(38.1)
2-1/8
(54)
N
3/4
(19.1)
1
(25.4)
23/32
(18.3)
1-11/32
(34.2)
Approx.
Shipping
Weight in
lbs (kg)
15
(6.8)
22
(10)
35.5
(16.1)
60
(22.1)
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-127
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 1 (Enclosure Code A) General Purpose Painted Enclosure for Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X,
512, 512M, 513, 513M, 522E, 522F, 522G, 523E, 523F, and 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573
Size 14
Size 5
NEMA Size
0...2
0...2
0...2
3
4
1PW, 2PW
1YD
3
3PW
2YD, 3YD
2
4PW
5PW
4YD
3, 4
5YD
5, 6
5
5PW
Bulletin No.
506X, 507X
502, 502L,
503, 503L,
512, 513
506, 507,
512M, 513M,
522E, 522F,
522G, 523E,
523F, 523G
502, 502L,
503, 503L,
512, 513
503, 503L,
513
530, 532, 533
540, 542, 543
506, 507,
522E, 522F,
522G, 523E,
523F, 523G
506, 507,
522E, 522F,
522G, 523E,
523F, 523G
502, 502L,
512
530, 532, 533
540, 542, 543
570, 572, 573
502, 502L,
503, 503L,
506, 506X,
507, 507X,
512, 513,
523E, 523F,
523G
530, 532, 533
532, 533
540, 542, 543
570, 572, 573
540, 542, 543
570, 572, 573
522E, 522F,
522G
530
A
Height
B
Width
C
Depth
D
Mounting
E
Mounting
F
Mounting
G
Handle Depth
Approx.
Shipping
Weight in lbs
(kg)
27.50
(968)
10.50
(267)
8.25
(210)
25.13
(639)
5.25
(133)
5.56
(141)
40
(18.14)
30
(762)
20.5
(521)
9.88
(251)
27.63
(702)
15.25
(387)
15.25
(387)
5.56
(141)
90
(40.82)
50
(1270)
22
(559)
11.19
(284)
47.63
(1210)
15.25
(387)
15.25
(387)
5.56
(141)
250
(113.4)
56
(1422)
30.5
(775)
13.79
(350)
57.63
(1463)
20
(508)
25.25
(641)
7.62
(194)
360
(163.3)
60
(1524)
37.38
(949)
16.00
(406)
61.69
(1567)
33.88
(861)
33.88
(861)
7.62
(194)
420
(190.5)
Sizes 0, 1 and 2 have one top mounting hole located on the center line. Larger size enclosures have two top mounting holes located as shown.
1-127
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-128
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 3R/4/12 (Enclosure Codes D, F, and J) Rainproof, Dusttight Industrial Use Enclosures for Bulletins 502,
502L, 503, 503L, 506, 506X, 507, 507X, 512, 512M, 513, 513M, 522E, 522F, 522G, 523E, 523F, 523G, 530, 532, 533, 540,
542, 543, 570, 572 and 573
Bulletin No.
506X, 507X
502, 507
503, 503L,
512, 513
0...2
506, 507,
512M, 513M,
522E, 522F,
522G, 523E,
523F, 523G
502, 507
3
503, 503L,
512, 513
4
513
1PW, 2PW
530, 532, 533
1YD
540, 542, 543
503, 503L,
506, 507, 513,
3
522E, 522F,
522G, 523E,
523F, 523G
502, 502L,
507, 512,
4
522E, 522F,
522G, 523E,
523F, 523G
3PW
530, 532, 533
2YD, 3YD
540, 542, 543
2
570, 572, 573
4PW
530, 532, 533
5PW
532, 533
4YD
540, 542, 543
3, 4
570, 572, 573
502, 502L,
503, 503L,
5
506, 512, 513
523E, 523F, 523G
6
512, 513
6
512
5
522E, 522F, 522G
5PW
530
5YD
540, 542, 543
5, 6
570, 572, 573
7
512, 513
Approx.
Shipping
Weight in
lbs (kg)
A
Height
B
Width
C
Depth
D
Mounting
E
Mounting
F
Mounting
G
Handle
Depth
27.50
(698)
10.50
(267)
8.25
(210)
28.88
(733)
5.25
(133)
5.56
(141)
29.88
(759)
0.81
(21)
40
(18.14)
30
(762)
20.5
(521)
10.19
(259)
31.38
(797.05)
15.25
(387)
15.25
(387)
5.56
(141)
32.38
(822)
0.81
(21)
90
(40.82)
50
(1270)
22
(559)
11.5
(292)
51.38
(1305)
15.25
(387)
15.25
(387)
5.56
(141)
52.38
(1330)
0.71
(18)
250
(113.4)
56
(1422)
30.5
(775)
13.79
(350)
57.63
(313)
20
(508)
25.25
(641)
7.62
(194)
62.62
(1590)
1
(25.4)
360
(163.3)
60
(1524)
37.38
(949)
16
(906)
61.69
(1567)
33.88
(861)
33.88
(861)
7.62
(194)
63.5
(1613)
1.5
(38)
420
(190.5)
84
(2134)
39.5
(1003)
18
(457)
7.62
(194)
650
(249.8)
Sizes 0, 1, and 2 have one top mounting hole located on the center line. All sizes in large enclosures have two top mounting holes located as shown.
1-128
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-129
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 4/4X (Enclosure Codes C) Stainless Steel Industrial Use Enclosures for Bulletins 502, 502L, 503, 503L, 506, 507,
512, 512M, 513, 513M, 522E, 522F, 522G, 523E, 523F, and 523G
Bulletin No.
1232X
1233X
1232X
1282, 1283
1242, 1243
1272, 1273
1232X
1233X
1282
1283
1242
1243
1272
1273
1232X
1233X
1282
1242
1272
1273
1232X
1232X
1232X, 1233X
Approx.
Shipping
Weight in
lbs (kg)
A
Height
B
Width
C
Depth
D
Mounting
E
Mounting
F
Mounting
G
Handle
Depth
30
(762)
20.5
(521)
8.72
(221)
34.88
(886)
10
(254)
10
(254)
5.56
(141)
36.38
(924)
90
(40.82)
50
(1270)
22
(559)
9.90
(251)
54.88
(1394)
15.25
(387)
15.25
(387)
5.56
(141)
56.38
(1432)
250
(113.4)
56
(1422)
30.5
(775)
13.78
(350)
5.56
(141)
40.72
(1034)
7.62
(194)
56
(1422)
30.5
(775)
13.78
(350)
7.62
(194)
34
(863)
7.62
(194)
9.68
(246)
360
(163.3)
60
(1524)
84
(2134)
37.38
(949)
39.5
(1003)
16
(406)
18
(457)
40.72
(1034)
42.84
(1088)
7.62
(194)
7.62
(194)
9.68
(246)
9.68
(246)
420
(190.5)
650
(294.8)
1-129
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-130
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 4/4X (Enclosure Codes "C") Stainless Steel Industrial Use Enclosures for Bulletins 502, 502L, 503, 503L, 506, 507,
512, 512M, 513, 513M, 522E, 522F, 522G, 523E, 523F, and 523G
0...2
3
4
56
5
6
56
Bulletin No.
502, 502L
503, 503L
512, 513
506, 507,
512M,
513M,
522E, 522F,
522G,
523E,
523F, 523G,
502, 502L,
503, 503L,
512, 513
503, 503L,
513
506, 507,
522E, 522F,
522G,
523E,
523F, 523G
502, 502L
506, 507,
512, 522F,
523G, 523E
523F, 523G
503, 503L
507, 513,
523E, 523F,
523G
512
512
502, 502L
506
E
Mounting
F
Mounting
G
Handle
Depth
Approx.
Shipping
Weight in
lbs (kg)
28.88
(733)
7
(178)
5.56
(141)
29.75
(756)
0.81
(21)
40
(18.14)
9.88
(251)
31.38
(797)
17
(432)
17
(432)
5.56
(141)
32.26
(819)
0.81
(21)
90
(40.82)
11.19
(284)
51.38
(1305)
18.5
(470)
18.5
(470)
5.56
(141)
52.26
(1327)
0.81
(21)
250
(113.4)
68.62
(1489)
1
(25.4)
360
(163.3)
A
Height
B
Width
C
Depth
D
Mounting
27.50
(698)
10.50
(267)
8.25
(210)
30
(762)
20.5
(521)
50
(1270)
22
(559)
5.56
(141)
56
(1422)
30.5
(775)
12.34
(313)
57.63
(1464)
20
(508)
25.25
(641)
7.62
(194)
Sizes 0, 1, and 2 have one top mounting hole located on the center line. All sizes in large enclosures have two top mounting holes located as shown.
1-130
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-131
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 4/4X (Enclosure Codes S) Non-metallic, Corrosion-resistant Enclosures for Bulletins 502, 502L, 503, 503L, 506,
507, 512, 513, 522E, 522F, 522G, 523E, 523F, and 523G
Bulletin No.
0...2
512, 513
0...2
3
4
3
506, 507,
522E, 522F,
522G, 523E,
523F, 523G,
512
513
506, 507,
522E, 522F,
522G, 523E,
523F, 523G
506, 507,
512, 523E,
523F, 523G
506, 507, 512,
513, 522E,
522F, 522G,
523E, 523F,
523G
A
Height
24
(610)
B
Width
10
(254)
C
Depth
6.88
(175)
D
Handle Depth
4.88
(124)
Approx.
Shipping
Weight in
lbs (kg)
28
(12.7)
24
(610)
21
(533)
9.25
(235)
4.88
(124)
60
(27.2)
49.19
(1249)
21.38
(543)
11
(279)
4.88
(124)
180
(81.6)
5.75
(146)
76.52
(1422)
21.63
(549)
19
(483)
5.75
(146)
280
(127)
1-131
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-132
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Type 3R (Enclosure Code N) Rainproof Enclosures with Extra Panel Space for Bulletins 1232X and 1233X
N
Bulletin No.
1232X,
1233X
NEMA Size
1
2
3
4
5
Inside
Outside
1-3/8 (35)
1 in Hub
1-23/32 (44)
1-1/4 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
1-23/32 (44)
1-1/4 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
1-31/32 (50)
1-1/2 in Hub
2-15/32 (63)
2 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
U
Bulletin No.
1232X, 1233X
NEMA Size
1
2
3
4
5
1-132
Outside
1-31/32 (50)
1-1/2 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
1-3/8 (35)
1 in Hub
1-3/8 (35)
1 in Hub
1-23/32 (44)
1-1/4 in Hub
1-31/32 (50)
1-1/2 in Hub
2-15/32 (63)
2 in Hub
1-31/32 (50)
1-1/2 in Hub
2-15/32 (63)
2 in Hub
Inside
Outside
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
T
Inside
W
Inside
Outside
7/8 (22)
1/2 in Hub
1-1/8 (29)
3/4 in Hub
1-31/32 (50)
1-1/2 in Hub
2-15/32 (63)
2 in Hub
3 (76)
2-1/2 in Hub
3 (76)
2-1/2 in Hub
3 (76)
2-1/2 in Hub
3-5/8 (96)
3 in Hub
3 (76)
2-1/2 in Hub
3-5/8 (96)
3 in Hub
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-133
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Unilock Enclosures Type 3R, 7 & 9, Class I (Enclosure Code U) Groups C & D, Class II, Groups E, F & G Divisions
1& 2 for Bulletins 505-509-513
1-133
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-134
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bolted Enclosures Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G Divisions 1 & 2
for Bulletin 505 Full Voltage Reversing Starters
NEMA Sizes 01
NEMA Sizes 24
NEMA Size
2
3
4
1-134
A WIDE
21
(533.4)
26-3/4
(679.5)
10-7/32
(259.6)
25-1/2
(647.7)
16-1/4
(412.8)
2-7/16
(61.9)
2-5/8
(66.7)
21-3/8
(542.9)
32-5/8
(828.7)
11-7/16
(290.5)
31-3/8
(796.9)
16-1/4
(412.8)
2-13/16
(71.4)
3-1/2
(88.9)
Bulletin_500Line_e.qxd
05/02/2004
17:40
Page 1-135
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bolted Enclosures Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G Divisions 1 & 2
for Bulletin 509 Full Voltage Starters
NEMA Sizes 02
NEMA Size
A WIDE
8-3/4
(222.2)
8-7/8
(225.4)
0-1
2
(MILLIMETERS)
D
14-3/16
(360.4)
17-7/16
(442.9)
E
5
(127)
5-3/8
(136.5)
NEMA Sizes 34
NEMA Size
3
4
A WIDE
12-3/4
(323.9)
15-1/8
(384.2)
10-3/8
(269.9)
31-3/8
(796.9)
10
(254)
2-9/18
(65.1)
G
2-5/8
(66.7)
3-1/2
(88.9)
NEMA Sizes 5
1-135
Bulletin_500Line_e.qxd
05/02/2004
17:41
Page 1-136
Approximate Dimensions
For NEMA AC Contactors
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bolted Enclosures Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G Divisions 1 & 2
for Bulletin 513 Full Voltage Combination Starters
NEMA Sizes 02
NEMA Sizes 34
NEMA Size
3
4
A WIDE
21
(533.4)
B HIGH
26-3/4
(679.5)
C DEEP
11-31/32
(304.1)
D
25-1/2
(647.7)
E
16-1/4
(412.8)
F
2-7/8
(73)
G
4-13/16
(122.2)
H
2-7/16
(61.9)
J
2-5/8
(66.7)
APPROX.
SHIP
WT. IN LBS.
(Kg)
200
(90)
21-3/8
(542.9)
32-5/8
(828.7)
13-3/16
(335)
31-3/8
(796.9)
16-1/4
(412.8)
2-11/16
(68.3)
5-1/4
(133.4)
2-13/16
(71.4)
3-1/2
(88.9)
275
(123.8)
NEMA Sizes 5
1-136
NEMA_Renewal_Parts.qxd
05/02/2004
17:48
Page 1-137
AC Operating Coils
Size 01
Size 15/2030 A
Size 00
Voltage (V)
24
Frequency
(Hz)
50
60
115120
110
60
50
110115
200208
208
220
220230
50
60
60
50
50
50
60
50
60
60
50
50
50
50
60
50
60
60
50
60
60
230240
240
277
380
415
440
440460
460480
440460
460480
480
500
575600
600
Voltage (V)
24
110115
200208
220230
Frequency
(Hz)
60
60
50
50
60
Series B
Series D
69A27
GA407
GA013
GA473
GA049
GA474
GA442
GA060
GA454
GA457
GA475
TA407
TA013
69A86
69A113
69A83
69A52
69A11
69A116
50
60
50
60
3-4-Pole
4-5-Pole
CC013
CC013C
CB236
CC236
CC236C
CC322
CC249
CC339
CC342
CC254
CC260
CC354
CC357
CC322C
CC249C
CC339C
CC342C
CC254C
CC260C
CC354C
CC357C
TA473
CB322
TA049
TA474
CB322C
CB249
CB339
CB342
CB339C
CB342C
CB254
TA480
TA071
TA457
CB260
CB354
CB357
CB354C
CB357C
GA475
GA464
GA476
Size 3
Size 100 A
TA475
TA475
TA479
CB360
CB360C
CC360
CC273
CC364
CC278
CC360C
CC273C
CC364C
CC278C
3-4-Pole
4-5-Pole
3-4-Pole
4-5-Pole
2-Pole
2-3-Pole
60
2-Pole
2-3-Pole
50
4-Pole
2-3-Pole
4-5-Pole
Part. No.
CB013
69A288
69A81
230240
277
380
415
440460
460480
500
575600
Series A
Size 2
Size 60 A
TA476
CB273
CB364
CB364C
CB278
Size 4
Size 200 A
2-Pole
2-3-Pole
Size 5
Size 300 A
3-4-Pole
4-5-Pole
Series A
Series L
Part No.
CD013
CD013C
CD236
CD236C
CE236
CE236C
CF236
AF236
CD322
CD249
CD339
CD342
CD254
CD260
CD354
CD357
CD360
CD273
CD364
CD278
CD322C
CD249C
CD339C
CD342C
CD254C
CD260C
CD354C
CD357C
CD360C
CD273C
CD364C
CD278C
CE322
CE249
CE339
CE342
CE254
CE260
CE354
CE357
CE360
CE273
CE364
CE278
CE322C
CE249C
CE339C
CE342C
CE254C
CE260C
CE354C
CE357C
CE360C
CE273C
CE364C
CE278C
CF322
CF249
CF339
CF342
CF254
CF260
CF354
CF357
CF360
CF273
CF364
CF278
AF322
AF249
AF339
AF342
AF254
AF260
AF354
AF357
AF360
AF273
AF364
AF278
1-137
NEMA_Renewal_Parts.qxd
05/02/2004
17:48
Page 1-138
00 (Series A)
4-Pole
Z-21103
40410-331-51
15/20 A
23
40410-331-53
0
1
40410-331-52
30 A
23
40410-331-54
1P
40410-331-55
60 A
23
40420-322-52
23
40430-300-52
2
40420-322-51
100 A
40430-300-53
4
40430-300-51
23
40440-325-52
3
200 A
40440-300-51
4
40440-325-53
4
2
Z-34042
Z-34119
5 (Series A)
300 A (Series A)
Z-34043
Z-34120
3
5 (Series L)
42450-805-01
300 A (Series L)
23
42450-805-02
540A
6 (Series B&C)
40783-802-02
40783-802-02
3
(Series B&C)
00 (Series A)
00 (Series B & D)
01
1P
2
3
Note: Auxiliary contacts on Size 3 and 4 overload relays are replaceable. Order Cat. No. 595-A34. See page 1-94 for complete information.
There are no replacement contacts for Series B and Series D, Size 00 device.
Noted part numbers are for a complete set of movable contacts and springs. Stationary contacts are available only as part of the Stationary Contact Block
Assembly.
Not for use on Power Pole Adders. Replace complete Power Pole Adder Kit with one selected from the listing on page 1-94.
Does not accommodate terminal mounted current transformers.
Accommodates terminal mounted current transformers.
Mounting Plate is not included.
Size
01
2
3
4
1-138
Power Pole Adder Kit (Used Only for 4- and 5-Pole Devices)
Motor Rated Contactors and Starters
Cat. No.
599-P01A
599-P2A
599-P3A
599-P4A
Non-Motor Rated Contactors
Rating (A)
Part No.
15/20
30
60
100
200
300
40410-452-04
40410-452-08
40420-452-04
40430-453-51
40440-452-51
42450-600-01
NEMA_Renewal_Parts.qxd
05/02/2004
17:49
Page 1-139
Size 0 through 5
Size 00
Voltage (V)
24
110
120
208
220
240
440
480
550
600
Frequency
(Hz)
60
50
60
60
50
60
50
60
50
60
Size 00
Size 0
69A27
70A27
Size 5
69A86
70A86
71A86
72A86
72A803
73A86
73A803
74A86
74A803
CF236
69A113
70A113
71A113
72A113
72A875
73A113
73A875
74A113
74A875
CF249
69A83
70A83
71A83
72A83
72A804
73A83
73A804
74A83
74A804
CF254
69A288
70A288
71A288
72A288
72A805
73A288
73A805
74A288
74A805
CF273
69A81
70A81
71A81
72A81
72A987
73A81
73A987
74A81
74A987
CF278
NEMA Size
00, 0, 1, 5
2
Single Pole
Manual
Reset Overload
Relay (Less
Element)
Size 4
2-3-Pole 45-Pole
Block Style
Manual Reset
Overload Relay
(Less Element)
1 N.C.
Cat. No.
815-BOV16
815-COV16
Block Style
1 N.O.-1 N.C.
Cat. No.
815-BOV169
815-COV169
815-DOV4
815-DOV49
815-DOV16
815-DOV169
815-EOV4
815-EOV49
815-EOV16
815-EOV169
NEMA Size
No. of
Contacts
00
N/A
Z-34037
Z-34038
Z-34039
Z-34040
Z-34041
2
3
Z-21101
Z-21102
Z-21103
5
Z-34042
Z-34042
1-139
Bulletin_500_Overload_Relay_Code_Selection.qxd
05/02/2004
17:53
Page 1-140
For use with Bulletins 505, 505V, 506, 507, 509, 512, 512M, 513,
520, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1232X,
1233X, 1242, 1243, 1272, 1273, 1282, and 1283.a
For use with Bulletins 505, 505V, 506, 507, 509, 512, 512M, 513,
1232X, and 1233X.
NEMA
Size
00
0, 1
1PW
1YD
1
2
2PW
2YD
3
3PW
3YD
4
4PW
4YD
5
5PW
5YD
6
6PW
6YD
Full Load
Current
Adjustment
Range (A)
3 Manual Reset
Overload Relay Code
3 Automatic/Manual
Reset Overload Relay
Code
Class
Class
Class
10
20
30
A4A
A5A
A6A
A4C
A5C
A6C
A4D
A5D
A6D
A4E
A5E
A6E
A4F
A5F
A6F
A4B
A5B
A6B
A4C
A5C
A6C
A4D
A5D
A6D
A4E
A5E
A6E
A4F
A5F
A6F
A4G
A5G
A6G
A4H
A5H
A6H
A4G
A5G
A6G
A4H
A5H
A6H
A4J
A5J
A6J
A4J
A5J
A6J
A4K
A5K
A6K
A4L
A5L
A6L
A4K
A5K
A6K
A4L
A5L
A6L
A4M
A5M
A6M
0.10.32
0.321.0
1.02.9
1.65.0
3.712
0.190.6
0.321.0
1.02.9
1.65.0
3.712
5.718
1238
5.718
1238
1445
1445
2375
66110
2375
66110
57180
Class
10
A1A
A1C
A1D
A1E
A1F
A1B
A1C
A1D
A1E
A1F
A1G
A1H
A1G
A1H
A1J
A1J
A1K
A1L
A1K
A1L
A1M
Class
20
A2A
A2C
A2D
A2E
A2F
A2B
A2C
A2D
A2E
A2F
A2G
A2H
A2G
A2H
A2J
A2J
A2K
A2L
A2K
A2L
A2M
Class
30
A3A
A3C
A3D
A3E
A3F
A3B
A3C
A3D
A3E
A3F
A3G
A3H
A3G
A3H
A3J
A3J
A3K
A3L
A3K
A3L
A3M
96300
A1N
A2N
A3N
A4N
A5N
A6N
200630
A1R
A2R
A3R
A4R
A5R
A6R
256810
3841215
8002250
Bulletins 520, 522 and 523 require two overload relay codes to complete
the Cat. No. The first code will denote the high speed overload relay and
the second code will denote the low speed overload relay.
Bulletins 530, 1282 and 1283 have two overload relays and require two
overload relay codes to complete the Cat. No. When selecting the proper
SMP overload relay, divide motor nameplate full load amperes by 2.00. Use
this value to select the proper overload relay codes.
a Bulletins 540, 1242 and 1243 have one overload relay. When selecting the
proper SMP overload relay, divide motor nameplate full load amperes by
1.73. Use this value to select the proper overload relay code.
These solid-state overload relays have an interposing relay with a 120V AC
coil.
Order by description.
1-140
NEMA
Size
00
0, 1
1
2
Full Load
Current
Adjustment
Range (A)
27
515
27
515
1238
515
1445
1 Manual Reset
Overload Relay Code
Class
10
S1A
S1B
S1A
S1B
S1C
S1B
S1F
Class
20
S2A
S2B
S2A
S2B
S2C
S2B
S2F
1 Automatic/Manual
Reset Overload Relay
Code
Class
10
S4A
S4B
S4A
S4B
S4C
S4B
S4F
Class
20
S5A
S5B
S5A
S5B
S5C
S5B
S5F
Bulletin_500_Overload_Relay_Code_Selection.qxd
05/02/2004
17:53
Page 1-141
00
1, 0
1
2
4
5
6
7
8
9
Automatic/Manual Reset
Overload Relay Code
B1A
B1C
B1D
B1E
B1F
B1B
B1C
B1D
B1E
B1F
B1G
B1H
B1G
B1H
B1J
B1J
B1K
B1L
B1K
B1L
B1M
B1N
B1R
Bulletins 520, 522, and 523 require two overload relay codes to complete
the Cat. No. The first code will denote the high speed overload relay and
the second code will denote the low speed overload relay.
Bulletins 530, 1282, and 1283 have two overload relays and require two
overload relay codes to complete the Cat. No. When selecting the proper
solid-state overload relay, divide motor nameplate full load amperes by
2.00. Use this value to select the proper overload relay codes.
Bulletins 540, 1242, and 1243 have one overload relay. When selecting the
proper solid-state overload relay, divide motor nameplate full load amperes
by 1.73. Use this value to select the proper overload relay code.
Order by description.
02
02
57
70300
C1N
67
140630
C1R
00
1, 0
2
3
4
1-141
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-142
Bulletin 592
Table of Contents
Product Overview . . . this page
Product Selection . . . 1-143
Accessories . . . . . . . . . 1-143
Specifications . . . . . . . 1-144
Trip Curves . . . . . . . . . 1-146
Dimensions . . . . . . . . . 1-147
Standards Compliance
IEC EN 60947-4-1
EN 60947-5-1
CSA 22.2 No. 14
UL 508
Certifications
CE Marked
CSA Certified C22.2 No. 14
(File No. LR1234)
UL Listed per UL 508
Description
Accurate, Reliable Performance
Rugged Construction
Application Flexibility
y Isolated Contacts
The isolated contact configuration allows the N.C. and N.O.
contacts to be applied in circuits operating at different voltage
levels and without polarity restrictions. The B600 contact rating
affords application in circuits rated to 600V.
y DIP Switch Settings
DIP switch settings allow the selection of trip class (10, 15, 20 or
30) and the reset mode (manual or automatic), making these
devices very versatile.
y Straightforward Installation
The self-powered design means that the E1 Plus Overload Relay
installs like traditional overload relays. Device setup is
accomplished by simply dialing the setting potentiometer to the
motor FLA rating. The low energy consumption of the electronic
design minimizes temperature rise issues inside control cabinets.
y Wide Adjustment Range
A wide 5:1 adjustment range results in the need for half as many
catalog numbers as the bimetallic alternative in order to cover the
same current range. This helps to reduce inventory carrying costs
and affords greater installation flexibility for dual voltage machines.
Evenly spaced setting tick marks enhance the ease of installation
setup.
1-142
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-143
Bulletin 592
00
02
Adjustment Range
0.10.5 A
0.21.0 A
1.05.0 A
3.216 A
0.21.0 A
1.05.0 A
3.216 A
5.427 A
945 A
945 A
1890 A
Cat. No.
592-EEAT
592-EEBT
592-EECT
592-EEDT
592-EEBC
592-EECC
592-EEDC
592-EEEC
592-EEFC
592-EEFD
592-EEGD
Adjustment Range
1.05.0 A
3.216 A
5.427 A
1.05.0 A
3.216 A
5.427 A
945 A
1890 A
Cat. No.
592S-EEPT
592S-EERT
592S-EEST
592S-EEPC
592S-EERC
592S-EESC
592S-EETC
592S-EEUD
02
Accessories
Description
Pkg. Qty.
Cat. No.
592-EE (all)
10
193-BC8
1-143
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-144
Bulletin 592
Specifications
Cat. No. 592-EE_T
Main Circuits
Rated
Rated
Rated
Rated
Insulation Voltage Ui
Impulse Strength Uimp
Operating Voltage Ue
Operating Frequency
Terminal Cross-Sections:
Stranded / Solid
Terminal Type
Terminal Screw
Single Conductor
Torque
Two Conductor
Torque
M5
146 AWG
22 lb-in
1410 AWG
30 lb-in
2
1x6
Control Circuits
M5
146 AWG
22 lb-in
1410 AWG
30 lb-in
2
1x6
690V AC
6 kV AC
690V AC (IEC) / 600V AC (CSA/UL)
B600.
N.O. / N.C
12120V
220240V
380480V
500600V
3
1.5
0.75
0.6
/
/
/
/
2
1.5
0.75
0.6
24V
110V
220V
440V
1.1
0.4
0.2
0.08
/
/
/
/
1.1
0.4
0.2
0.08
5A
Contact Reliability
17V, 5 mA
For multiple conductor applications, the same style and size of wire must be used.
1-144
M8
121 AWG
35 lb-in
62 AWG
35 lb-in
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-145
Bulletin 592
Terminal Screw
Single Conductor
Torque
Two Conductor
Torque
Screwdriver (mm)
Environmental Ratings
Ambient Temperature
Humidity
Storage
Operating
Operating
Damp Heat
-4085 C (-40185 F)
-2060 C (-4140 F)
595%, non-condensing
per IEC 68-2-3 and IEC 68-2-30
3G
30G
2000 m
Pollution Degree 3
IP20
RF Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Level
Level
Level
Level
Level
Level
Performance Level
General
Standards
Certifications
Weight
kg
lb
UL508, CSA C22.2 No. 14, NEMA ICS 2-1993 Part 4, EN 60947-4-1, EN 60947-5-1
CE, CSA, UL
0.25
0.25
0.52
1.06
0.55
0.55
Environment 2
1-145
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-146
Bulletin 592
Typical reset time for 193-EE devices set to automatic reset mode is 120 seconds
1-146
Bulletin_592_E1.qxd
05/02/2004
18:01
Page 1-147
Bulletin 592
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Size 00
Size 03
Contactor
592-EE__C
Size 0 and 1
592-EE__C
Size 2
592-EE__D
Size 3
A
91
(3-9/16)
100
(3-15/16)
155.5
(6-1/8)
B
198
(7-25/32)
233
(9-11/64)
336.7
(13-1/4)
C
114
(4-1/2)
114
(4-1/2)
154
(6-1/16)
D
5.2
(13/64)
5.2
(13/64)
7.1
(9/32)
F
113
(4-7/16)
119
(4-11/16)
150.1
(5-29/32)
H1
180
(7-1/16)
219
(8-5/8)
219.9
(8-21/32)
H2
70
(2-3/4)
80
(3-5/32)
139.9
(5-1/2)
J
9.8
(3/8)
9.8
(3/8)
19.9
(25/32)
1-147
Bulletin_592_E3.qxd
05/02/2004
18:05
Page 1-148
Bulletin 592
Table of Contents
592-EC1
y 0.490 A Current Range
y DeviceNet Ready (ODVA Conformance Tested)
y LED Indicators and Test/Reset Button
y Adjustable Trip Class 530
y Ambient Temperature Compensation
y True RMS Current Sensing (20250 Hz)
y Protection for Single- and Three-Phase Motors
y Integrated I/O (2 In / 1 Out)
y Programmable Trip and Warning Settings
y Diagnostic Functions (History of Last 5 Trips)
592-EC2 also includes
y Integrated I/O (4 In / 2 Out)
y Low-Level (15 A) Ground Fault Protection
y PTC Thermistor Monitoring
y DeviceLogix Component Technology (series B only)
Standards Compliance
EN 60947-4-1
CSA 22.2 No. 14
UL 508
Certifications
CE
cULus (File No. E14840) (Guide
No. NKCR)
C-tick
Description
Protective/Warning Functions:
Thermal overload
Phase loss (Trip only)
Ground Fault (E3 Plus)
Stall (Trip only)
Jam
Underload
PTC (E3 Plus)
Current imbalance
592 EC1
a
a
c
c
Type
Description
E3
E3 Plus
Code
EC1
EC2
Code
P
A
B
C
D
E
Code
T
C
D
Bulletin 500
Contactor Size
Description
Size 00
Size 02
Size 3
Product Selection
Your order must include 1) the Cat. No. of the overload relay selected, and 2) if required, Cat. No. of any accessories.
y 2 Inputs
y 1 Output
y 4 Inputs
y 2 Outputs
For Installation on
Starter Size
00
02
Adjustment Range
0.42.0 A
15 A
315 A
0.42.0 A
15 A
315 A
525 A
945 A
945 A
1890 A
Cat. No.
592-EC1PT
592-EC1AT
592-EC1BT
592-EC1PC
592-EC1AC
592-EC1BC
592-EC1CC
592-EC1DC
592-EC1DD
592-EC1ED
For applications greater than 90 A, see the Bulletin 193 panel mount
devices for use with external current transformers.
1-148
For Installation on
Starter Size
00
02
Cat. No.
592-EC2PT
592-EC2AT
592-EC2BT
592-EC2PC
592-EC2AC
592-EC2BC
592-EC2CC
592-EC2DC
592-EC2DD
592-EC2ED
For applications greater than 90 A, see the Bulletin 193 panel mount
devices for use with external current transformers.
Bulletin_592.qxd
05/02/2004
18:18
Page 1-149
Bulletin 592
Bulletin 592
Table of Contents
Standards Compliance
UL 508
CSA 22.2 No. 14
CE Mark
Certifications
UL Listed (File No. E14840)
(Guide No. NKCR)
CSA Certified (File No. LR1234)
Your order must include: 1) Cat. No. of overload relay selected, 2) order heater element as a separate item. See page 1-152, and 3) if
required, Cat. No. of any accessories.
N.C. Contact
Cat. No.
592-JOV16
592-BOW16
592-COW16
592-DOW16
592-EOW16
Number of Poles
3
3
3
3
3
N.O.-N.C. Contact
Cat. No.
592-JOV169
592-BOW169
592-COW169
592-DOW169
592-EOW169
Type
Compact
Maximum
Continuous Current
(A)
24
32
40
Standard
62
125
165
Number of Poles
3
3
1
3
1
3
3
3
Open Type
without Enclosure
N.C. Contact
N.O.-N.C. Contacts
Cat. No.
Cat. No.
592-JOV16
592-JOV169
592-KOV16
592-KOV169
592-BOV4
592-BOV49
592-BOV16
592-BOV169
592-COV4
592-COV49
592-COV16
592-COV169
592-DOV16
592-DOV169
592-EOV16
592-EOV169
Type 1
General Purpose Enclosure
N.C. Contact
N.O.-N.C. Contacts
Cat. No.
Cat. No.
592-BAV16
592-BAV169
592-CAV16
592-CAV169
Cat. No.
592-TPD200
592-TPD300
592-TPD400
592-TPD630
For Renewal Part Overload Relay used on starter mounted devices, see page page 1-138.
1-149
Bulletin_592.qxd
05/02/2004
18:18
Page 1-150
Bulletin 592
Open Type without Enclosure for Bulletin 592 Eutectic Alloy Type Manual Reset Panel Mount
Dimensions are shown in inches (millimeters). Dimensions are not to be used for manufacturing purposes.
Maximum
Current (A)
No. of
Poles
24/32
3
1
40
3
1
62
3
A
Wide
2-11/16
(68.3)
7/8
(22.2)
3-15/16
(100)
7/8
(22.2)
3-15/16
(100)
B
High
3-1/4
(82.6)
3-1/4
(82.6)
3-13/16
(96.8)
3-31/32
(101)
C
Deep
3-41/64
(92.6)
3-9/16
(90.5)
4-1/2
(114)
3-9/16
(90.5)
4-1/2
(114)
2-29/32
(73.8)
3-21/32
(93)
3-1/8
(79.4)
3-21/32
(93)
E
2-3/4
(70)
F
55/64
(22)
J
1/4
(6.4)
K
29/32
(23)
3-5/32
(80)
3-5/32
(80)
1-3/64
(26.5)
1-3/8
(35)
1-9/64
(7.5)
25/64
(9.9)
3-5/32
(80)
3-5/32
(80)
1-3/64
(26.5)
1-3/8
(35)
2-3/4
(69.8)
1-9/64
(7.5)
25/64
(9.9)
5/16
(7.9)
23/64
(9.1)
2-3/4
(69.8)
5/16
(7.9)
23/64
(9.1)
125
6-7/32
(158)
5-7/8
(149)
4-49/64
(121)
6-1/4
(159)
5-1/2
(140)
5-1/2
(140)
1-61/64
(49.6)
165
6-7/32
(158)
6-17/32
(166)
4-49/64
(121)
6-1/4
(159)
5-1/2
(140)
5-1/2
(140)
1-61/64
(49.6)
Open Type without Enclosure for Bulletin 592 Current Transformer Type Eutectic Alloy, Manual Reset
Cat. No.
592-TPD200
592-TPD300
592-TPD400
592-TPD630
A
Wide
5-5/16
(135)
6-63/64
(177.3)
6-63/64
(177.3)
9-27/32
(250)
B
High
5-19/32
(142)
5-19/32
(142)
10-15/32
(266)
7-55/64
(210)
C
Deep
8-9/16
(217.5)
9-5/32
(233)
9-5/32
(233)
8-19/32
(218)
D
4-23/32
(120)
4-23/32
(120)
4-23/32
(120)
7-3/32
(180)
E
4-23/32
(120)
6-9/64
(156)
6-9/64
(156)
8-57/64
(226)
F
19/64
(7.5)
27/64
(10.6)
27/64
(10.6)
15/32
(12)
1-150
G
1-59/64
(49)
22-1/2
(63.6)
22-1/2
(63.6)
3-19/64
(84)
H
29/64
(12)
29/64
(12)
29/64
(12)
25/64
(10)
J
51/64
(10)
51/64
(10)
51/64
(10)
51/64
(10)
K
21/64
(8.4)
9/32
(7)
9/32
(7)
9/32
(7)
Bulletin_592.qxd
05/02/2004
18:18
Page 1-151
Bulletin 592
A
Wide
6-13/16
(173)
B
High
10-5/8
(270)
C
Deep
5-23/32
(145)
D
8-1/4
(210)
E
2-3/8
(60.5)
F
7/32
(5.5)
G
5-5/16
(135)
1-151
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-152
J CLASS 10
P CLASS 20 (Bul. 600 ONLY)
W CLASS 20
WL CLASS 30
Description
Overload Relay Class Designation
United States Industry Standards (NEMA Part ICS 2-222) designate
an overload relay by a class number indicating the maximum time in
seconds at which it will trip when carrying a current equal to 600
percent of its current rating.
A Class 10 overload relay will trip in 10 seconds or less at a current
equal to 600 percent of its rating.
A Class 20 overload relay will trip in 20 seconds or less at a current
equal to 600 percent of its rating.
A Class 30 overload relay will trip in 30 seconds or less at a current
equal to 600 percent of its rating.
Allen-Bradley standard overload relay protection is provided using
Type W heater elements for the 500 Line. This provides Class 20
operation and is recommended for General Applications.
Specific Applications may require Class 10 or Class 30 overload
relays. Class 10 overload relays are often used with hermetic
motors, submersible pumps, or motors with short locked rotor time
capability. Class 30 overload relays should be used with motors
driving high inertia loads, where additional accelerating time is
needed and the safe permissible locked rotor time of the motor is
within Class 30 performance requirements.
For applications requiring Class 30 protection, Type WL heater
elements are available. To order, use the applicable Type W
selection table, follow the heater element selection instructions and
change the W in the Heater Type Number to WL.
For applications requiring Class 10 overload relays, Type J elements
are available. See page page 1-155 for Index to Heater Element
Selection Tables.
1-152
Table of Contents
Overload Relay
Class Designation . . . this page
Heater Element
Selection . . . . . . . . . . . this page
Ambient
Temperature
Correction . . . . . . . . . . this page
Heater Element
Selection Procedure this page
Time Current
Characteristics . . . . . . 1-154
Index to Heater
Element Selection
Tables . . . . . . . . . . . . . . 1-155
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-153
Now, using this correction factor, the readjusted full load current
value can be determined by:
Both correction factors are selected from the curve for the type
of heater element to be used. The heater element selection
tables are based on a +40 C ambient temperature. This means
the correction factor for a +40 C is 1.00. In other words, there is
no correction factor at +40 C.
2. Next in this heater element selection process is to adjust the
motor nameplate full load current (FLC) by the C.F. Ratio. This
readjusted value of motor nameplate full load current (FLC) is the
yardstick in selecting the proper heater element.
3. The last step is to refer to the suggested heater element table
and pick the element whose rating for the given controller size is
closest to FLC.
For Bulletin 512, Size 2, again refer to Table 153. The value of 30.9
A falls between 30.0 A (W64) and 32.5 A (W66). Since 30.0 is closer
to 30.9 specify the W64 heater element.
Example 3: Starter Lower than +40 C Motor Higher. 3-Phase,
AC, squirrel cage motor, 25 Hp, 460V, 60 Hz, 1800 rpm. FLC of 34
A, service factor 1.15. Type W heater elements, Temperature at
starter +25 C, Temperature at motor +55 C.
Next, consider a case where both the controller and the motor are
at ambient temperatures other than +40 C. In Example 3 the
temperature of the controller is +25 C ambient (cooler) while the
temperature of the motor is +55 C ambient (warmer). As stated
earlier, a motor running in a warmer environment will deliver less
than its normal horsepower. This requires downsizing the heater
element rating. The controller in this case is in a cooler environment
which prevents the heater element from heating up as much as in a
+40 C ambient temperature. This also requires downsizing the
heater element rating to provide adequate protection. Thus, the net
effect of a warmer motor and a cooler controller is to further
downsize the heater element. Using the Type W temperature
correction curve, the correction factor in this case is:
Table 153 shows that this value falls between 28.0 A (W63) and 30.0
A (W64). Because 28.0 A is closer to the requirement, select the
heater element W63.
1-153
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-154
This correction factor allows a heater element with current rating of:
This means that the rating of the heater element should be 90% of
the normal nameplate motor full load current or:
For Bulletin 512, Size 2 controller, Table 153 shows this rating to fall
between 30.0 A (W64) and 32.5 A (W65). Because 32.5 A is closer,
select heater element W65. Note here that the net effect has been
to downsize the heater element rating compared to a normal +40 C
ambient operation.
Note: The heater element selection tables are designed to
accommodate motor service factors of 1.15 or greater, as given in
all the preceding examples. If the service factor had been less than
1.15 (for example, S.F. = 1.0) a heater element one rating smaller
than selected in each example would have been the correct choice.
This would provide protection at 10% lower current levels.
1-154
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-155
Bulletin
Number
Encl.
Type
105, 109
Open
505
Open, 1,
3R/4/12
505
Open 1,
3R/4/12,
4/4X
505
4/4X
505
4X
Unilock
3R/7 & 9
Bolted
3R/7 & 9,
7&9
Open
505
505
505V
506, 507
1, 3R/12,
4/4X, 4X
507
1, 3R/4/
12,4/4X, 4X
507
Bolted
3R/7 & 9,
7&9
509
Open, 1,
3R/12
Open
1, 3R/4/12
509
509
509 with
control
1, 3R/4/12
transformer
Open, 1,
509
3R/4/12
Open, 1,
509
3R/4/12,
4/4X
Open 1,
509
3R/4/12,
4/4X
509
4/4X
509
4X
509
Unilock
3R/7 & 9
509
Bolted
3R/7 & 9,
7&9
512
1, 3R/4/12,
4/4X, 4X
512M
3R/4/12
513
1, 3R/4/12,
4/4X, 4X
513
Unilock
3R/7 & 9
Size
930 A
36110 A
180 A
00
04
5
6
Table No.
Manual Reset
Type W Element
Type J Element
1
1
Relay, 3 Relays, Relay, 3 Relays,
1
3
1
3
180
182
191
187
195
196
127
180
55
182
156
151
164
162
347
547
195
196
78
133
132
04
5
02
146
177
145
158
178
158
01
166
159
03
171
172
156
168
164
162
04
04
5
6
7
02
3
4
154
149
347
195
134
168
168
171
161
547
196
165
172
162
172
00
127
180
55
182
04, 1P
04
156
155
152
150
164
164
163
162
04, 1P
156
150
164
162
347
547
195
Bulletin
Number
Encl.
Type
513
Bolted
3R/7 & 9,
7&9
520
Open, 1,
3R/4/12
520
4/4X
520
4X
Bolted
3R/7 & 9,
7&9
Bolted
3R/7 & 9,
7&9
520E
520F & G
Size
03
4
5
04
5
6
7
04
5
02
03
Table No.
Manual Reset
Type W Element
Type J Element
3
3
1 Relay, Relays, 1 Relay, Relays,
1
3
1
3
168
172
168
160
168
160
151
162
347
547
195
196
133
132
146
158
177
178
145
158
171
172
168
162
02
168
172
168
162
150
162
148
162
347
195
547
196
133
132
152
162
347
195
547
196
570
196
592
Open
592
592 with
current
transformer
1PW
2PW
3PW
4PW
5PW
6PW
7PW
8PW
1YD
4YD
5YD
6YD
7YD
8YD
24
5
6
789
2432 A
40165 A
40165 A
Open
195
196
600
All
5
(Type P)
609,
609RS,
609TS,
609U,
609TU
All
011P
112
110
117
116
1232X,
1233X
02
3, 4
5
152
149
347
163
163
547
78
133
132
03
4
5
02
04
5
03, 1P
4
5
04
5
6
12
04
5
6
7
04
5
156
156
144
148
177
146
166
177
171
171
171
153
347
195
153
148
347
195
134
167
169
164
164
158
178
158
159
178
172
162
547
163
547
196
163
160
547
196
165
159
178
530
540
133
132
192
192
154
347
195
133
180
191
181
198
198
162
547
196
132
182
187
183
When selecting heater elements for Bulletin 530, divide the motor
nameplate full load amperes by 2.00 use this value to select the proper
Heater Element Cat. No..
When selecting heater elements for Bulletin 540, divide the motor
nameplate full load amperes by 1.73 use this value to select the proper
Heater Element Cat. No..
1-155
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-156
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
Size 00
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.48
0.53
0.58
0.65
0.71
0.78
0.87
0.95
1.05
1.16
1.28
1.41
1.55
1.70
1.87
2.06
2.27
2.51
2.78
3.07
3.38
3.72
4.10
4.52
4.98
5.49
6.04
6.66
7.35
8.13
8.96
9.90
TABLE 55
Full Load Amperes
Size 0
Size 1 Size 1P
0.22
0.22
0.24
0.24
0.27
0.27
0.30
0.30
0.33
0.33
0.36
0.36
0.40
0.40
0.44
0.44
0.48
0.48
0.53
0.53
0.58
0.58
0.65
0.65
0.71
0.71
0.78
0.78
0.87
0.87
0.95
0.95
1.05
1.05
1.16
1.16
1.28
1.28
1.41
1.41
1.55
1.55
1.70
1.70
1.87
1.87
2.06
2.06
2.27
2.27
2.51
2.51
2.78
2.78
3.07
3.07
3.38
3.38
3.72
3.72
4.10
4.10
4.52
4.52
4.98
4.98
5.49
5.49
6.04
6.04
6.66
6.66
7.35
7.35
8.13
8.13
8.96
8.96
9.90
9.90
10.9
10.9
11.0
12.0
12.0
12.2
13.2
13.2
13.4
14.6
14.6
14.8
16.1
16.1
16.3
17.7
17.7
17.9
19.5
19.8
21.4
21.8
23.6
24.0
26.0
26.4
28.5
29.0
32.0
35.0
38.5
Size 2
18.3
20.2
22.2
24.4
26.9
29.8
33.0
36.5
40.5
45.5
1-156
Size 3
40.5
45.5
51
56
62
68
74
82
90
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-157
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
TABLE 110
Full Load Amperes
Size 0
Size 1
0.18
0.18
0.20
0.20
0.22
0.22
0.24
0.24
0.27
0.27
0.30
0.30
0.33
0.33
0.36
0.36
0.40
0.40
0.44
0.44
0.48
0.48
0.53
0.53
0.59
0.59
0.65
0.65
0.71
0.71
0.78
0.78
0.86
0.86
0.95
0.95
1.05
1.05
1.16
1.16
1.27
1.27
1.41
1.41
1.55
1.55
1.71
1.71
1.89
1.89
2.08
2.08
2.30
2.30
2.53
2.53
2.79
2.79
3.07
3.07
3.38
3.38
3.73
3.73
4.11
4.11
4.51
4.51
4.96
4.96
5.44
5.44
5.98
5.98
6.57
6.57
7.21
7.21
7.92
7.92
8.70
8.70
9.57
9.5
10.5
10.5
11.6
11.6
12.7
12.7
14.0
14.0
15.4
15.4
16.8
16.8
18.3
18.3
19.9
21.7
23.6
25.7
28.0
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
Size 0
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.49
0.54
0.59
0.65
0.71
0.78
0.86
0.94
1.04
1.14
1.26
1.39
1.53
1.69
1.86
2.05
2.26
2.49
2.74
3.02
3.33
3.67
4.04
4.45
4.89
5.38
5.92
6.51
7.16
7.87
8.66
9.52
10.5
11.5
12.6
13.9
15.2
16.7
18.3
TABLE 112
Full Load Amperes
Size 1
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.49
0.54
0.59
0.65
0.71
0.78
0.86
0.94
1.04
1.14
1.26
1.39
1.53
1.69
1.86
2.05
2.26
2.49
2.74
3.02
3.33
3.67
4.04
4.45
4.89
5.38
5.92
6.51
7.16
7.87
8.66
9.52
10.5
11.5
12.6
13.9
15.2
16.7
18.3
19.9
21.8
23.8
26.0
28.5
Size 1P
10.5
11.5
12.6
13.9
15.2
16.7
18.3
19.9
21.8
23.8
26.0
28.5
31.0
34.0
37.0
1-157
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:39
Page 1-158
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
TABLE 116
Full Load Amperes
Size 0
Size 1
0.19
0.19
0.21
0.21
0.23
0.23
0.26
0.26
0.29
0.29
0.31
0.31
0.35
0.35
0.39
0.39
0.43
0.43
0.47
0.47
0.52
0.52
0.58
0.58
0.64
0.64
0.71
0.71
0.79
0.79
0.87
0.87
0.96
0.96
1.07
1.07
1.18
1.18
1.31
1.31
1.45
1.45
1.60
1.60
1.76
1.76
1.94
1.94
2.13
2.13
2.35
2.35
2.59
2.59
2.85
2.85
3.14
3.14
3.45
3.45
3.80
3.80
4.19
4.19
4.62
4.62
5.08
5.08
5.60
5.60
6.17
6.17
6.80
6.80
7.48
7.48
8.24
8.24
9.08
9.08
10.0
10.0
11.0
11.0
12.2
12.2
13.6
13.6
15.1
15.1
16.7
16.7
18.6
18.6
20.4
22.5
24.8
27.5
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
Size 0
0.20
0.22
0.24
0.27
0.30
0.33
0.37
0.40
0.45
0.50
0.55
0.60
0.67
0.74
0.82
0.91
1.00
1.11
1.22
1.35
1.49
1.66
1.83
2.02
2.24
2.48
2.75
3.03
3.35
3.70
4.10
4.53
5.01
5.54
6.13
6.78
7.49
8.29
9.16
10.1
11.2
12.4
13.7
15.2
16.8
18.5
TABLE 117
Full Load Amperes
Size 1
0.20
0.22
0.24
0.27
0.30
0.33
0.37
0.40
0.45
0.50
0.55
0.60
0.67
0.74
0.82
0.91
1.00
1.11
1.22
1.35
1.49
1.66
1.83
2.02
2.24
2.48
2.75
3.03
3.35
3.70
4.10
4.53
5.01
5.54
6.13
6.78
7.49
8.29
9.16
10.1
11.2
12.4
13.7
15.2
16.8
18.5
20.5
22.8
25.0
27.5
1-158
Size 1P
12.4
13.7
15.2
16.8
18.5
20.5
22.8
25.0
27.5
30.0
33.5
36.0
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:40
Page 1-159
Heater Element
Cat. No.
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
TABLE 132
Full Load Amperes
Size 7
Size 8
231
350
253
380
276
415
305
455
330
495
360
540
400
600
440
660
485
722
530
795
585
880
645
965
710
1160
780
1170
860
1290
Heater Element
Cat. No.
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
TABLE 133
Full Load Amperes
Size 7
Size 8
230
345
248
375
272
410
305
460
325
485
355
535
390
585
430
645
475
710
520
780
575
860
630
945
690
1035
755
1135
835
1255
TABLE 134
Heater Element
Cat. No.
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
Size 7
240
261
285
310
340
370
405
445
490
540
590
650
710
780
860
1-159
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:40
Page 1-160
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
1-160
Size 0
0.18
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.38
0.42
0.46
0.51
0.56
0.62
0.68
0.75
0.82
0.90
0.99
1.09
1.20
1.32
1.45
1.59
1.75
1.93
2.12
2.33
2.56
2.81
3.09
3.40
3.74
4.11
4.52
4.97
5.46
6.01
6.60
7.26
7.98
8.78
9.65
10.6
11.7
12.8
14.1
15.4
16.8
18.3
TABLE 144
Full Load Amperes
Size 1
Size 2
Size 3
0.18
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.38
0.42
0.46
0.51
0.56
0.62
0.68
0.75
0.82
0.90
0.99
1.09
1.20
1.32
1.45
1.59
1.75
1.93
2.12
2.33
2.56
2.81
3.09
3.40
3.74
4.11
4.52
4.97
5.46
5.60
6.01
6.15
6.60
6.76
7.26
7.43
7.98
8.17
8.78
8.98
9.65
9.87
10.6
10.8
11.7
11.9
12.8
13.1
14.1
14.4
15.4
15.7
16.8
17.1
18.3
18.6
19.8
20.1
21.3
21.7
25.5
22.7
23.1
28.1
24.4
24.8
31.0
26.2
28.6
34.0
28.2
30.5
37.0
33.0
40.0
35.5
43.5
38.0
47
40.5
51
43.5
55
47.0
59
63
67
71
76
80
85
90
Size 4
32.0
35.0
38.5
42.5
46.5
51
55
59
64
69
74
79
84
90
96
102
107
113
118
124
130
135
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.88
6.41
6.99
7.63
8.32
9.07
9.89
10.8
11.8
12.9
14.2
15.5
16.8
18.5
TABLE 145
Full Load Amperes
Size 1
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.88
6.41
6.99
7.63
8.32
9.07
9.89
10.8
11.8
12.9
14.2
15.5
16.8
18.5
20.3
22.2
24.0
26.1
28.4
Size 2
5.58
6.11
6.70
7.34
7.97
8.69
9.52
10.4
11.4
12.5
13.6
14.9
16.2
17.4
19.3
21.0
23.0
25.0
27.1
29.6
32.0
34.5
38.0
41.5
45.0
Bulletin_Eutectic_Alloy_Overload_Relays_1.qxd
05/02/2004
18:40
Page 1-161
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
Size 0
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.88
6.41
6.99
7.63
8.32
9.07
9.89
10.8
11.8
12.8
14.0
15.3
16.7
18.1
TABLE 146
Full Load Amperes
Size 1
Size 2
Size 3
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.53
5.88
6.04
6.41
6.60
6.99
7.21
7.63
7.87
8.32
8.60
9.07
9.39
9.89
10.3
10.8
11.2
11.8
12.2
12.8
13.3
14.0
14.6
15.3
15.8
16.7
17.3
18.1
18.9
19.7
20.6
21.5
22.5
25.5
23.5
24.6
28.1
25.7
26.8
31.0
27.5
29.4
34.0
32.0
37.0
34.5
40.0
37.5
43.5
41.0
47.0
44.5
51
47.0
55
59
63
67
71
76
80
85
90
Size 4
32.0
35.0
38.5
42.5
46.5
51
55
59
64
69
74
79
84
90
96
102
107
113
118
124
130
135
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.36
0.39
0.43
0.48
0.52
0.57
0.62
0.69
0.76
0.83
0.91
1.01
1.12
1.22
1.34
1.47
1.62
1.78
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.84
4.22
4.65
5.12
5.63
6.20
6.82
7.51
8.23
9.07
9.95
10.8
11.9
13.0
14.2
15.5
16.4
17.7
19.7
TABLE 148
Full Load Amperes
Size 1
Size 2
Size 3
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.36
0.39
0.43
0.48
0.52
0.57
0.62
0.69
0.76
0.83
0.91
1.01
1.12
1.22
1.34
1.47
1.62
1.78
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.84
4.22
4.65
5.12
5.13
5.63
5.64
6.20
6.22
6.82
6.85
7.51
7.56
8.23
8.45
9.07
9.32
9.95
10.3
10.6
10.8
11.4
11.6
11.9
12.4
12.6
13.0
13.6
13.9
14.2
14.8
15.3
15.5
16.1
16.9
16.4
17.3
18.7
17.7
18.7
20.7
19.7
20.6
22.8
21.7
22.7
25.1
24.2
25.2
27.5
27.0
28.0
30.5
30.0
33.5
32.5
36.5
35.0
39.5
38.0
42.5
40.5
46
43.5
50
46.5
54
58
62
67
72
76
81
86
90
Size 4
17.3
19.0
21.0
23.1
25.5
28.0
31.0
34.0
37.0
40.0
44.0
48.5
53.0
57.0
62.0
67.0
72.0
77.0
82.0
87.0
93.0
99.0
105
112
117
123
129
135
1-161
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:04
Page 1-162
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
1-162
Size 0
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.88
6.41
6.99
7.63
8.32
9.07
9.89
10.8
11.8
12.8
14.0
15.3
16.2
17.6
19.5
TABLE 149
Full Load Amperes
Size 1
Size 2
Size 3
0.18
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.17
1.29
1.42
1.56
1.71
1.89
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.05
4.45
4.90
5.39
5.53
5.88
6.00
6.41
6.60
6.99
7.20
7.63
7.84
8.32
8.53
9.07
9.30
9.89
10.2
10.6
10.8
11.2
11.6
11.8
12.2
12.6
12.8
13.2
13.9
14.0
14.4
15.3
15.3
15.8
16.9
16.2
16.8
18.7
17.6
18.3
20.7
19.5
20.3
22.8
21.5
22.4
25.1
23.4
24.4
27.5
25.7
26.8
30.5
27.5
28.7
33.5
31.5
37.0
34.0
41.0
37.0
44.0
40.5
47.5
43.5
52.0
46.5
57.0
61.0
66.0
71.0
75.0
79.0
83.0
87.0
91.0
Size 4
18.5
20.5
22.5
25.0
27.5
30.0
33.0
36.0
39.5
43.0
47.5
52.0
56.0
61.0
66.0
71.0
76.0
81.0
87.0
93.0
99.0
105
111
118
125
132
139
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.46
0.50
0.55
0.60
0.67
0.73
0.80
0.88
0.97
1.07
1.17
1.29
1.42
1.57
1.73
1.90
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.04
4.46
4.94
5.46
6.03
6.65
7.33
8.13
8.95
9.90
10.7
11.7
12.8
14.0
15.3
16.2
17.5
19.4
TABLE 150
Full Load Amperes
Size 3
Size 2
Size 1
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.46
0.50
0.55
0.60
0.67
0.73
0.80
0.88
0.97
1.07
1.17
1.29
1.42
1.57
1.73
1.90
2.08
2.28
2.51
2.76
3.04
3.34
3.68
4.04
4.46
5.13
4.94
5.64
5.46
6.22
6.03
6.85
6.65
7.56
7.33
8.45
8.13
9.32
8.95
10.4
10.3
9.90
11.4
11.3
10.7
12.5
12.3
11.7
13.7
13.4
12.8
15.1
14.5
14.0
16.7
15.8
15.3
18.4
16.7
16.2
20.3
18.0
17.5
22.5
19.9
19.4
24.8
21.9
21.3
27.2
24.2
23.3
30.0
26.8
25.5
33.0
28.7
27.2
36.0
31.0
39.5
33.5
43.5
36.0
47.5
38.5
52.0
41.5
56.0
45.0
60.0
65.0
69.0
74.0
79.0
85.0
91.0
Size 4
18.5
20.5
22.5
25.0
27.5
30.0
33.0
36.0
39.5
43.0
47.0
51.0
56.0
61.0
66.0
71.0
76.0
82.0
87.0
93.0
99.0
105
111
118
125
132
139
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:05
Page 1-163
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.36
0.39
0.43
0.48
0.52
0.57
0.62
0.69
0.76
0.83
0.91
1.01
1.12
1.22
1.34
1.47
1.62
1.78
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.84
4.22
4.65
5.12
5.63
6.20
6.82
7.51
8.23
9.07
9.95
10.8
11.9
13.0
14.2
15.5
16.4
17.7
19.7
TABLE 151
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.36
0.39
0.43
0.48
0.52
0.57
0.62
0.69
0.76
0.83
0.91
1.01
1.12
1.22
1.34
1.47
1.62
1.78
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.84
4.22
4.65
5.13
5.12
5.64
5.63
6.22
6.20
6.85
6.82
7.56
7.51
8.45
8.23
9.32
9.07
10.6
10.3
9.95
11.6
11.3
10.8
12.6
12.3
11.9
13.9
13.4
13.0
15.3
14.5
14.2
16.9
15.8
15.5
18.7
16.7
16.4
20.7
18.1
17.7
22.8
20.0
19.7
25.1
22.0
21.7
27.5
24.5
24.2
30.5
27.3
27.0
33.5
29.2
36.5
31.5
40.0
34.5
44.0
37.0
48.0
39.5
52.0
42.5
57.0
46.0
61.0
66.0
70.0
75.0
80.0
86.0
92.0
Size 4
25.0
27.7
31.0
34.0
38.0
41.5
45.5
49.0
53.0
57.0
62.0
67.0
72.0
77.0
84.0
92.0
97.0
102
109
117
125
130
136
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
Size 0
0.19
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.50
0.55
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.16
1.27
1.39
1.51
1.65
1.80
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.85
4.23
4.68
5.18
5.68
6.28
6.94
7.71
8.45
9.29
10.3
11.4
12.5
13.7
15.0
16.3
17.6
18.9
TABLE 152
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.50
0.55
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.16
1.27
1.39
1.51
1.65
1.80
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.85
4.23
4.68
5.25
5.18
5.81
5.68
6.41
6.28
7.09
6.94
7.86
7.71
8.56
8.45
9.40
9.29
10.6
10.4
10.3
11.6
11.5
11.4
12.6
12.6
12.5
13.9
13.8
13.7
15.3
15.1
15.0
16.9
16.4
16.3
18.7
17.7
17.6
20.7
19.1
18.9
22.8
21.1
20.9
25.1
23.2
22.9
27.5
25.7
25.0
30.5
28.5
27.6
33.5
30.5
36.5
33.0
40.0
35.5
44.0
38.5
48.5
41.5
53.0
45.0
58.0
62.0
67.0
72.0
77.0
82.0
88.0
94.0
Size 4
18.5
20.5
22.5
25.0
27.5
30.0
33.0
36.0
39.5
43.0
47.0
51.0
56.0
61.0
66.0
72.0
77.0
83.0
89.0
95.0
102
108
116
123
130
137
1-163
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:05
Page 1-164
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
1-164
Size 0
0.19
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.5
0.55
0.6
0.66
0.73
0.8
0.88
0.97
1.06
1.16
1.27
1.39
1.51
1.65
1.8
1.98
2.18
2.39
2.63
2.9
3.19
3.5
3.85
4.24
4.66
5.13
5.64
6.2
6.82
7.51
8.25
9.07
9.98
11
12.1
13.3
14.6
16
17.4
19
TABLE 153
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.50
0.55
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.16
1.27
1.39
1.51
1.65
1.80
1.98
2.18
2.39
2.63
2.90
3.19
3.50
3.85
4.24
4.66
5.25
5.13
5.78
5.64
6.35
6.20
6.99
6.82
7.69
7.51
8.45
8.25
9.32
9.07
10.6
10.3
9.98
11.6
11.4
11.0
12.6
12.4
12.1
13.9
13.6
13.3
15.3
15.0
14.6
16.9
16.4
16.0
18.7
17.8
17.4
20.7
19.5
19.0
22.8
21.2
20.7
25.1
23.3
22.7
27.5
25.3
24.7
30.5
28.0
27.0
33.5
30.0
36.5
32.5
39.5
35.0
42.5
38.0
46.0
40.5
50.0
43.5
54.0
46.5
58.0
62.0
67.0
72.0
76.0
81.0
86.0
90.0
Size 4
18.5
20.5
22.5
25.0
27.5
30.0
33.0
36.0
39.5
43.0
47.0
51.0
56.0
61.0
66.0
71.0
76.0
82.0
87.0
93.0
99.0
105
111
118
125
132
139
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.38
0.42
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.55
1.70
1.90
2.02
2.22
2.43
2.68
2.96
3.25
3.58
3.94
4.30
4.72
5.22
5.78
6.38
7.06
7.83
8.55
9.41
10.5
11.6
12.7
14.0
15.3
16.7
18.0
TABLE 154
Full Load Amperes
Size 1
Size 2
Size 3
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.38
0.42
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.55
1.70
1.90
2.02
2.22
2.43
2.68
2.96
3.25
3.58
3.94
4.30
4.72
5.22
5.25
5.78
5.81
6.38
6.41
7.06
7.09
7.83
7.86
8.55
8.58
9.41
9.48
10.5
10.6
11.1
11.6
11.7
12.2
12.7
12.8
13.4
14.0
14.1
14.7
15.3
15.4
16.3
16.7
16.9
17.9
18.0
18.3
19.7
19.3
19.9
21.7
21.3
21.9
23.8
23.3
24.2
26.1
25.6
26.8
28.7
28.1
29.6
31.5
32.5
34.5
35.0
38.0
37.5
41.5
41.0
45.5
45.0
49.5
54
59
64
70
76
81
87
93
Size 4
19.5
21.4
23.7
26.0
28.7
31.5
34.5
37.5
41.0
44.5
48.5
53
58
63
68
74
80
86
92
98
105
112
120
128
136
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:06
Page 1-165
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
Size 0
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.56
1.70
1.88
2.05
2.24
2.44
2.69
2.97
3.30
3.64
4.10
4.57
5.01
5.51
6.06
6.62
7.22
7.89
8.62
9.41
10.5
11.6
12.7
14.0
15.3
16.7
18.0
TABLE 155
Full Load Amperes
Size 2
Size 1P
Size 1
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.56
1.70
1.88
2.05
2.24
2.44
2.69
2.97
3.30
3.64
4.10
4.57
5.01
5.48
5.51
6.09
6.06
6.65
6.62
7.26
7.22
7.94
7.89
8.68
8.62
9.48
9.41
10.6
10.5
11.7
11.6
11.6
12.8
12.7
12.7
14.1
14.0
14.0
15.4
15.3
15.3
16.8
16.7
16.7
18.1
18.0
18.0
19.5
19.3
19.3
21.5
21.3
21.3
23.8
23.3
23.3
26.4
25.6
25.6
29.2
28.1
28.1
31.5
30.5
34.0
32.5
36.5
34.0
39.5
36.0
42.5
46.0
Size 3
11.5
12.6
13.8
15.1
16.7
18.3
20.1
22.1
24.4
27.0
29.5
32.5
35.0
38.5
42.0
46.0
50
54
59
64
70
76
81
87
93
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.57
1.72
1.90
2.08
2.28
2.49
2.74
3.02
3.33
3.68
4.14
4.61
5.06
5.56
6.11
6.72
7.40
8.18
8.88
9.70
10.8
11.8
12.9
14.2
15.5
17.0
18.3
TABLE 156
Full Load Amperes
Size 1 Size 1P Size 2
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.57
1.72
1.90
2.08
2.28
2.49
2.74
3.02
3.33
3.68
4.14
4.61
5.06
5.56
5.57
6.11
6.12
6.72
6.73
7.40
7.38
8.18
8.20
8.88
8.92
9.70
9.81
10.8
10.9
11.8
11.8
11.9
12.9
12.9
13.0
14.2
14.2
14.3
15.5
15.5
15.6
17.0
17.0
17.1
18.3
18.3
18.5
19.9
19.9
20.1
22.0
22.0
22.2
24.3
24.3
24.5
27.0
27.0
27.2
29.5
30.0
32.0
33.0
34.0
35.5
36.0
38.0
41.5
45.0
Size 3
11.7
12.8
13.9
15.2
16.8
18.5
20.2
22.2
24.5
27.1
29.9
32.5
35.5
39.0
42.5
47.0
52
57
62
67
73
79
85
92
Size 4
19.5
21.4
23.7
26.0
28.7
31.5
34.5
37.5
41.0
44.5
48.5
53
58
63
68
74
80
86
93
100
108
116
125
135
1-165
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:06
Page 1-166
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
J77
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.58
3.96
4.37
4.82
5.32
5.87
6.48
7.15
7.89
8.70
9.56
10.5
11.5
12.7
13.9
15.3
16.8
18.5
TABLE 158
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.58
3.96
4.37
4.82
5.32
5.87
6.48
7.15
7.89
8.84
8.70
9.71
9.56
10.7
10.5
11.8
11.5
13.0
12.7
14.4
13.9
15.9
15.3
17.6
16.8
21.6
19.4
18.5
23.9
21.4
20.3
26.5
23.5
22.3
29.3
25.8
24.5
32.5
28.8
27.0
36.0
32.5
40.0
36.0
44.0
39.0
49
42.0
55
45.0
60
66
72
78
84
92
Size 4
34.5
38
42
46
51
57
62
68
74
80
87
95
104
113
122
132
143
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
1-166
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.59
3.96
4.37
4.82
5.32
5.87
6.48
7.15
7.89
8.70
9.56
10.5
11.5
12.7
13.9
15.3
16.8
18.5
TABLE 159
Full Load Amperes
Size 1
Size 2
Size 3
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.59
3.96
4.37
4.82
5.32
5.87
6.48
7.15
7.89
8.70
8.84
9.56
9.71
10.5
10.7
11.5
11.7
12.7
12.9
13.9
14.2
15.3
15.8
16.8
17.5
18.5
19.4
20.9
20.3
21.2
23.2
22.3
23.2
25.7
24.6
25.3
28.4
27.0
27.7
31.5
30.5
35.0
33.0
39.0
36.0
43.5
39.5
48.5
43.0
54
47.0
59
64
70
77
85
92
Size 4
31.5
35.0
38.5
43.0
47.0
51
56
61
67
73
81
90
99
108
118
129
140
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:07
Page 1-167
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.93
1.03
1.14
1.26
1.39
1.53
1.68
1.86
2.05
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
7.19
7.94
8.78
9.71
10.7
11.8
13.1
14.5
16.0
17.7
19.6
TABLE 160
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.93
1.03
1.14
1.26
1.39
1.53
1.68
1.86
2.05
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
6.50
7.21
7.19
7.99
7.94
8.85
8.78
9.81
9.71
10.9
10.7
12.1
11.8
13.4
13.1
14.9
14.5
16.5
16.0
18.3
17.7
22.2
20.2
19.6
24.5
22.4
21.6
27.1
24.8
23.9
29.9
27.4
26.4
33.0
30.5
29.3
36.5
33.5
40.5
37.0
45.0
41.0
50
45.5
56
61
67
73
80
87
95
Size 4
33.5
37.5
41.5
46.5
52
57
63
68
75
83
91
99
108
117
126
135
Size 5
76
83
91
100
108
117
127
138
150
165
179
195
211
230
250
272
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.93
1.03
1.13
1.24
1.37
1.51
1.66
1.84
2.02
2.22
2.45
2.70
2.97
3.27
3.61
3.98
4.39
4.84
5.34
5.89
6.49
7.16
7.91
8.73
9.58
10.6
11.7
13.0
14.4
15.9
17.6
19.5
TABLE 161
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.93
1.03
1.13
1.24
1.37
1.51
1.66
1.84
2.02
2.22
2.45
2.70
2.97
3.27
3.61
3.98
4.39
4.84
5.34
5.89
6.49
7.16
7.91
9.11
8.73
10.1
9.58
11.1
10.6
12.2
11.7
13.5
13.0
14.9
14.4
16.4
15.9
18.1
17.6
22.2
20.0
19.5
24.5
22.1
21.5
27.1
24.3
23.6
29.9
26.8
25.9
33.0
29.5
28.5
36.5
32.5
40.5
35.5
45.0
39.0
50
43.0
56
47.5
61
67
73
80
87
95
Size 4
34.5
38.5
42.5
47.0
52
58
64
70
77
85
93
102
112
123
135
1-167
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:07
Page 1-168
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
1-168
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.59
3.99
4.42
4.87
5.41
5.98
6.61
7.26
7.98
8.77
9.61
10.6
11.7
13.0
14.4
15.9
17.5
19.4
TABLE 162
Full Load Amperes
Size 3
Size 2
Size 1
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.76
0.84
0.92
1.02
1.12
1.23
1.36
1.50
1.65
1.82
2.00
2.20
2.43
2.68
2.95
3.25
3.59
3.99
4.42
4.87
5.41
6.04
5.98
6.73
6.61
7.41
7.26
8.19
7.98
9.05
8.77
10.0
9.61
11.1
10.6
12.2
11.7
13.5
13.0
14.9
14.4
16.5
15.9
18.3
17.5
21.6
20.2
19.4
23.9
22.4
21.3
26.5
24.8
23.3
29.3
27.4
25.5
32.5
30.5
28.0
36.0
33.5
40.0
37.5
44.5
41.0
49.5
45.0
55
60
66
72
78
85
92
Size 4
33.5
37.5
41.0
46.5
52
57
63
68
75
83
91
99
108
117
126
135
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
Size 0
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.77
0.86
0.95
1.06
1.18
1.32
1.44
1.58
1.72
1.88
2.06
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
7.19
7.94
8.78
9.71
10.7
11.8
13.1
14.5
16.0
17.7
19.6
TABLE 163
Full Load Amperes
Size 1
Size 2
Size 3
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.77
0.86
0.95
1.06
1.18
1.32
1.44
1.58
1.72
1.88
2.06
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
6.50
7.19
7.21
7.94
8.52
8.78
9.30
9.71
10.2
10.7
11.1
11.8
12.1
13.1
13.4
14.5
14.9
16.0
16.5
17.7
18.3
19.6
20.2
21.8
21.7
22.4
23.9
23.9
24.8
26.6
26.4
27.4
29.6
29.3
30.5
33.0
33.5
37.0
37.0
41.0
41.0
45.5
45.5
51
56
61
67
73
79
87
95
Size 4
33.5
37.5
41.5
46.0
52
57
63
69
76
84
92
102
112
123
135
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:08
Page 1-169
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
Size 0
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.59
0.65
0.72
0.80
0.88
0.97
1.07
1.18
1.31
1.44
1.59
1.76
1.94
2.14
2.36
2.60
2.86
3.15
3.46
3.81
4.19
4.61
5.07
5.58
6.14
6.75
7.47
8.26
9.14
10.1
11.2
12.4
13.7
15.2
16.8
18.6
TABLE 164
Full Load Amperes
Size 2
Size 1P
Size 1
0.20
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.49
0.54
0.59
0.65
0.72
0.80
0.88
0.97
1.07
1.18
1.31
1.44
1.59
1.76
1.94
2.14
2.36
2.60
2.86
3.15
3.46
3.81
4.19
4.61
5.07
5.58
6.14
6.75
6.75
7.49
7.47
8.31
8.26
9.22
9.14
10.2
10.1
11.3
11.2
11.2
12.6
12.4
12.4
14.0
13.7
13.7
15.5
15.2
15.2
17.1
16.8
16.8
19.0
18.6
18.6
21.0
20.5
20.5
23.2
22.7
22.7
25.7
25.1
25.1
28.4
27.8
27.8
31.5
30.5
35.0
34.0
39.0
38.0
43.5
48.0
TABLE 165
Size 3
23.3
25.8
28.8
31.5
35.5
39.5
44.0
47.0
52
58
63
69
76
84
92
Heater Element
Cat. No.
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
1-169
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:08
Page 1-170
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
1-170
Size 0
0.19
0.21
0.23
0.25
0.27
0.30
0.32
0.36
0.39
0.43
0.47
0.52
0.56
0.62
0.68
0.74
0.82
0.90
0.98
1.05
1.16
1.29
1.40
1.55
1.70
1.84
2.02
2.22
2.45
2.63
2.89
3.17
3.48
3.82
4.19
4.60
5.05
5.54
6.08
6.68
7.33
8.05
8.83
9.70
10.6
11.7
12.8
14.1
15.5
17.0
18.6
TABLE 166
Full Load Amperes
Size 1
Size 2
Size 3
0.19
0.21
0.23
0.25
0.27
0.30
0.32
0.36
0.39
0.43
0.47
0.52
0.56
0.62
0.68
0.74
0.82
0.90
0.98
1.05
1.16
1.29
1.40
1.55
1.70
1.84
2.02
2.22
2.45
2.63
2.89
3.17
3.48
3.82
4.19
4.60
5.1
5.05
5.6
5.54
6.12
6.08
6.65
6.68
7.25
7.33
7.9
8.05
8.6
8.83
9.4
9.70
10.2
10.6
11.2
11.7
12.2
12.8
13.4
14.1
14.7
15.5
16.2
17.0
17.7
18.6
19.4
20.4
21.3
25.0
22.4
23.4
27.3
24.6
25.6
29.8
27.0
28.1
32.5
30
35.5
32.5
39.0
35
42.0
37.5
46.0
40
51.0
42.0
55.0
44.5
59.0
47.0
64.0
69.0
74.0
79.0
83.0
88.0
93.0
Size 4
33.5
37.0
40.5
44.5
49.0
54.0
59.0
64.0
69.0
74.0
79.0
84.0
90.0
96.0
102
108
116
123
131
139
Size 5
72
78
85
92
100
109
118
128
139
151
164
181
198
218
240
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
W85
Size 0
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.45
0.49
0.54
0.59
0.65
0.71
0.78
0.85
0.93
1.01
1.12
1.22
1.34
1.47
1.61
1.76
1.93
2.11
2.31
2.53
2.77
3.03
3.32
3.63
3.97
4.35
4.76
5.21
5.71
6.25
6.84
7.48
8.20
8.98
9.83
10.8
11.8
12.9
14.1
15.5
17.0
18.7
TABLE 167
Full Load Amperes
Size 1
Size 2
Size 3
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.45
0.49
0.54
0.59
0.65
0.71
0.78
0.85
0.93
1.01
1.12
1.22
1.34
1.47
1.61
1.76
1.93
2.11
2.31
2.53
2.77
3.03
3.32
3.63
3.97
4.35
4.58
4.76
5.02
5.21
5.50
5.71
6.02
6.25
6.60
6.84
7.23
7.48
7.92
8.20
8.68
8.98
9.51
9.83
10.4
10.8
11.4
11.8
12.5
12.9
13.7
14.1
15.0
15.5
16.4
17.0
17.9
18.7
19.5
20.5
21.3
25.5
22.4
23.3
28.0
24.6
25.4
30.5
27.0
27.4
33.5
29.5
36.5
32.0
40.0
34.5
43.5
37.0
47.5
39.0
51.0
41.0
55.0
43.0
60.0
45.0
65.0
69.0
74.0
78.0
83.0
88.0
93.0
Size 4
32.0
35.0
38.0
41.5
45.0
49.0
54.0
58.0
63.0
68.0
73.0
79.0
85.0
90.0
97.0
103
109
115
121
126
131
137
Size 5
72
78
84
91
99
107
116
125
136
147
159
174
191
210
Bulletin_Eutectic_Alloy_Overload_Relays_2.qxd
05/02/2004
19:09
Page 1-171
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
W84
Size 0
0.18
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.82
0.94
1.02
1.12
1.23
1.38
1.50
1.64
1.78
1.95
2.10
2.28
2.57
2.83
3.12
3.47
3.84
4.26
4.68
5.18
5.71
6.28
6.90
7.59
8.35
9.28
10.2
11.2
12.1
13.3
14.5
15.7
16.6
17.8
19.6
TABLE 168
Full Load Amperes
Size 3
Size 2
Size 1
0.18
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.39
0.43
0.47
0.51
0.56
0.61
0.67
0.74
0.82
0.94
1.02
1.12
1.23
1.38
1.50
1.64
1.78
1.95
2.10
2.28
2.57
2.83
3.12
3.47
3.84
4.26
4.78
4.68
5.28
5.18
5.79
5.71
6.35
6.28
6.97
6.90
7.65
7.59
8.40
8.35
9.30
9.28
10.2
10.2
11.2
11.2
12.2
12.1
13.4
13.3
14.7
14.5
16.1
15.7
17.6
16.6
19.3
17.8
21.1
19.6
25.0
22.9
21.5
27.7
25.0
23.5
30.5
27.1
25.7
34.0
29.5
28.2
36.5
32.0
39.5
34.5
42.5
37.0
46.0
40.0
51
42.5
55
45.0
59
64
69
74
79
83
88
93
TABLE 169
Size 4
34.0
37.0
40.0
44.0
48.5
53
57
62
67
72
77
82
87
93
99
105
112
117
123
129
135
Size 5
70
76
82
90
98
106
115
125
137
150
162
176
191
210
230
249
270
Heater Element
Cat. No.
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
1-171
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:26
Page 1-172
Heater
Element
Cat. No. Size 00
W10
0.17
W11
0.19
W12
0.21
W13
0.22
W14
0.25
W15
0.28
W16
0.31
W17
0.34
W18
0.37
W19
0.42
W20
0.46
W21
0.50
W22
0.56
W23
0.62
W24
0.69
W25
0.76
W26
0.84
W27
0.93
W28
1.02
W29
1.13
W30
1.25
W31
1.38
W32
1.49
W33
1.61
W34
1.74
W35
1.89
W36
2.04
W37
2.22
W38
2.49
W39
2.75
W40
3.03
W41
3.37
W42
3.73
W43
4.13
W44
4.55
W45
5.02
W46
5.53
W47
6.08
W48
6.68
W49
7.34
W50
8.07
W51
8.95
W52
9.83
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
1-172
TABLE 171
Full Load Amperes
Size 0
0.17
0.19
0.21
0.22
0.25
0.28
0.31
0.34
0.37
0.42
0.46
0.50
0.56
0.62
0.69
0.76
0.84
0.93
1.02
1.13
1.25
1.38
1.49
1.61
1.74
1.89
2.04
2.22
2.49
2.75
3.03
3.37
3.73
4.13
4.55
5.02
5.53
6.08
6.68
7.34
8.07
8.95
9.83
10.8
11.6
12.7
13.8
14.9
15.7
17.0
18.4
Size 1
0.17
0.19
0.21
0.22
0.25
0.28
0.31
0.34
0.37
0.42
0.46
0.50
0.56
0.62
0.69
0.76
0.84
0.93
1.02
1.13
1.25
1.38
1.49
1.61
1.74
1.89
2.04
2.22
2.49
2.75
3.03
3.37
3.73
4.13
4.55
5.02
5.53
6.08
6.68
7.34
8.07
8.95
9.83
10.8
11.6
12.7
13.8
14.9
15.7
17.0
18.4
20.0
21.8
24.5
27.8
Size 2
8.31
9.26
10.2
11.1
12.1
13.1
14.5
15.8
16.9
18.1
19.8
21.6
23.7
26.0
28.6
31.0
34.0
37.0
40.0
43.0
46.0
Size 3
12.5
13.8
15.2
16.5
17.9
19.7
21.8
24.2
26.5
29.3
32.0
36.0
38.0
42.0
46.0
50.0
53
58
62
66
70
74
80
85
89
94
Size 4
33.5
37.0
40.5
44.5
49.0
54.0
59
64
69
74
79
84
90
96
102
108
116
123
131
139
Size 5
71
78
85
92
100
109
119
130
140
153
166
180
200
222
248
267
295
Heater
Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
TABLE 172
Full Load Amperes
Size 0
0.19
0.21
0.23
0.26
0.29
0.31
0.35
0.38
0.41
0.46
0.50
0.56
0.61
0.67
0.75
0.82
0.91
1.00
1.11
1.22
1.34
1.47
1.62
1.78
1.96
2.17
2.40
2.65
2.92
3.21
3.54
3.91
4.30
4.75
5.22
5.76
6.36
7.03
7.75
8.57
9.44
10.4
11.4
12.7
14.0
15.4
17.0
18.7
Size 1
0.19
0.21
0.23
0.26
0.29
0.31
0.35
0.38
0.41
0.46
0.50
0.56
0.61
0.67
0.75
0.82
0.91
1.00
1.11
1.22
1.34
1.47
1.62
1.78
1.96
2.17
2.40
2.65
2.92
3.21
3.54
3.91
4.30
4.75
5.22
5.76
6.36
7.03
7.75
8.57
9.44
10.4
11.4
12.7
14.0
15.4
17.0
18.7
20.6
22.8
25.1
27.9
Size 2
8.08
8.90
9.86
10.8
11.9
13.2
14.5
15.9
17.6
20.5
22.4
24.6
27.1
29.8
33.0
36.0
40.0
43.0
47.0
Size 3
13.1
14.5
15.9
17.6
19.4
21.3
23.4
25.7
28.5
31.5
35.0
39.0
44.0
48
53
58
62
69
75
81
89
96
Size 4
31.5
35.0
38.5
43.0
47.0
51
56
61
67
73
81
90
99
108
118
129
140
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:26
Page 1-173
TABLE 180
Full Load Amperes
Size 5
70
76
82
90
98
106
115
125
137
150
162
176
191
210
230
248
270
Heater Element
Cat. No.
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
TABLE 178
Heater Element
Cat. No.
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
Heater Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
1-173
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:27
Page 1-174
1-174
Size
24 A
0.19
0.20
0.22
0.24
0.27
0.29
0.32
0.36
0.39
0.44
0.49
0.54
0.6
0.67
0.74
0.84
0.9
1
1.1
1.22
1.31
1.43
1.55
1.66
1.8
1.97
2.12
2.33
2.59
2.84
3.15
3.46
3.84
4.27
4.73
5.36
5.82
6.33
6.97
7.63
8.49
9.24
10.1
11.1
12.2
13.6
14.6
15.7
17.2
18.9
20.5
22.2
24.3
Size
32 A
0.19
0.2
0.22
0.24
0.27
0.29
0.32
0.36
0.39
0.44
0.49
0.54
0.60
0.67
0.74
0.84
0.90
1.00
1.10
1.22
1.31
1.43
1.55
1.66
1.80
1.97
2.12
2.33
2.59
2.84
3.15
3.46
3.84
4.27
4.73
5.36
5.82
6.33
6.97
7.63
8.49
9.24
10.1
11.1
12.2
13.6
14.6
15.7
17.2
18.9
20.5
22.2
24.3
26.4
28.5
32.5
TABLE 181
Full Load Amperes
Size
Size
40 A
62A
0.19
0.21
0.23
0.25
0.28
0.31
0.34
0.37
0.41
0.45
0.50
0.55
0.60
0.66
0.73
0.80
0.88
0.97
1.06
1.16
1.27
1.39
1.51
1.65
1.80
1.96
2.15
2.36
2.60
2.86
3.16
3.48
3.85
4.23
4.68
5.18
5.68
6.28
6.94
7.71
8.45
9.29
9.40
10.3
10.4
11.4
11.5
12.5
12.6
13.7
13.8
15.0
15.1
16.3
16.4
17.6
17.7
18.9
19.1
20.9
21.1
22.9
23.2
25.0
25.7
27.6
28.5
30.0
30.5
32.0
33.0
34.0
35.5
37.0
38.5
39.0
41.5
41.0
45.0
48.5
53
56
58
60
62
TABLE 182
Size
125 A
25.1
27.5
30.5
33.5
36.5
40
44
48.5
53
58
62
67
72
77
82
88
94
98
102
108
117
125
Size
165 A
43.0
47.0
51
56
61
66
72
77
83
89
95
102
108
116
123
130
137
150
160
165
Heater Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:27
Page 1-175
Heater
Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
J77
J78
Size
24 A
0.20
0.21
0.23
0.25
0.27
0.29
0.33
0.37
0.41
0.45
0.50
0.55
0.62
0.68
0.78
0.84
0.93
1.05
1.17
1.30
1.44
1.61
1.80
1.93
2.12
2.30
2.50
2.73
2.95
3.20
3.54
3.90
4.28
4.65
5.18
5.75
6.40
7.10
7.82
8.75
9.63
10.9
12.0
13.2
14.9
16.4
17.6
19.4
22.7
24.2
Size
32 A
0.20
0.21
0.23
0.25
0.27
0.29
0.33
0.37
0.41
0.45
0.50
0.55
0.62
0.68
0.78
0.84
0.93
1.05
1.17
1.30
1.44
1.61
1.80
1.93
2.12
2.30
2.50
2.73
2.95
3.20
3.54
3.90
4.28
4.65
5.18
5.75
6.40
7.10
7.82
8.75
9.63
10.9
12.0
13.2
14.9
16.4
17.6
19.4
22.7
24.2
26.9
30.0
34.0
TABLE 183
Full Load Amperes
Size
Size
40 A
62A
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.77
0.86
0.95
1.06
1.18
1.32
1.44
1.58
1.72
1.88
2.06
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
7.19
7.94
8.78
9.30
9.71
10.2
10.7
11.1
11.8
12.1
13.1
13.4
14.5
14.9
16.0
16.5
17.7
18.3
19.6
20.2
21.7
22.4
23.9
24.8
26.4
27.4
29.3
30.5
33.0
33.5
36.0
37.0
38.5
41.0
40.5
45.5
50.0
54.0
57.0
60.0
63.0
Size
125 A
26.6
29.6
33.0
37.0
41.0
45.5
51.0
56.0
61.0
67.0
73.0
79.0
87.0
95.0
101
111
122
Size
165 A
45.1
46
52
57
63
69
76
84
92
102
112
123
135
150
158
161
Heater
Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
J77
J78
Cat. No.
592-BOV16
0.19
0.21
0.23
0.26
0.28
0.31
0.34
0.38
0.42
0.46
0.51
0.57
0.63
0.69
0.77
0.86
0.95
1.06
1.18
1.32
1.44
1.58
1.72
1.88
2.06
2.25
2.48
2.73
3.01
3.31
3.65
4.02
4.42
4.87
5.37
5.91
6.50
7.19
7.94
8.78
9.71
10.7
11.8
13.1
14.5
16.0
17.7
19.6
21.7
23.9
26.4
29.3
33.0
36.0
38.5
42.5
TABLE 187
Full Load Amperes
Cat. No.
Cat. No.
592-COV16
592-DOV16
9.3
10.2
11.1
12.1
13.4
14.9
16.5
18.3
20.2
22.4
24.8
26.6
27.4
29.6
30.5
33.0
33.5
37.0
37.0
41.0
41.0
45.5
45.5
51
50
56
56
61
59
67
62
73
68
79
87
95
105
116
125
Cat No.
592-EOV16
41.5
46.0
52
57
63
69
76
84
92
102
112
123
135
155
165
172
1-175
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:27
Page 1-176
1-176
Cat. No.
592-BOV16
0.20
0.22
0.24
0.26
0.29
0.32
0.35
0.38
0.42
0.47
0.51
0.56
0.61
0.67
0.74
0.81
0.89
0.98
1.08
1.19
1.30
1.43
1.55
1.70
1.90
2.02
2.22
2.43
2.68
2.96
3.25
3.58
3.94
4.30
4.72
5.22
5.78
6.38
7.06
7.83
8.55
9.41
10.5
11.6
12.7
14.0
15.3
16.7
18.0
19.3
21.3
23.3
25.6
28.1
31.0
34.0
36.0
38.0
41.0
TABLE 191
Full Load Amperes
Cat. No.
Cat. No.
592-COV16
592-DOV16
9.48
10.6
11.7
12.8
14.1
15.4
16.9
18.3
19.9
21.9
24.2
26.1
26.8
28.7
29.6
31.5
32.5
34.5
35.0
38.0
37.5
41.5
41.0
45.5
45.0
49.5
48.0
54
52
59
57
64
60
70
63
76
65
81
68
87
93
100
105
110
120
Cat. No.
592-EOV16
41.0
44.5
48.5
53
58
63
68
74
80
86
92
98
105
112
120
128
136
145
154
162
170
Heater
Element
Cat. No.
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
W50
W51
W52
W53
W54
W55
W56
W57
W58
W59
W60
W61
W62
W63
W64
W65
W66
W67
W68
W69
W70
W71
W72
W73
W74
W75
W76
W77
W78
W79
W80
W81
W82
W83
TABLE 192
Full Load Amperes
Size 40 A
0.21
0.23
0.25
0.27
0.30
0.34
0.37
0.41
0.45
0.50
0.55
0.60
0.65
0.71
0.78
0.86
0.95
1.04
1.14
1.25
1.36
1.50
1.65
1.82
2.01
2.21
2.45
2.67
3.00
3.31
3.65
4.06
4.49
4.98
5.48
6.06
6.68
7.35
8.09
8.90
9.80
10.9
12.0
13.2
14.3
15.7
17.1
18.6
19.7
21.4
23.4
25.8
28.4
31.0
35.5
38.5
41.0
Size 68 A
9.03
9.96
11.1
12.2
13.3
14.6
15.8
17.5
19.1
20.5
21.9
24.1
26.4
29.1
32.0
35.5
39.0
42.5
47.5
53
57
60
65
71
Size 120 A
25.6
27.8
30.0
34.0
38.5
42.5
44.5
50
54
60
65
73
78
87
94
100
109
113
121
Size 184 A
43.5
47.5
52
58
61
66
74
80
89
97
104
113
125
133
142
153
165
170
184
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:28
Page 1-177
Cat. No.
592-TPD200
184 A
43
45
50
54
59
65
70
75
81
89
98
110
120
132
143
155
170
193
Cat. No.
592-TPD300
304 A
127
138
151
166
183
198
218
239
260
285
310
Cat. No.
592-TPD400
496 A
78
85
94
104
114
125
139
150
160
175
195
215
235
260
293
320
350
380
415
455
500
550
NEMA Size 6
Cat. No.
592-TPD630
608 A
115
125
135
147
165
179
196
216
232
260
287
315
350
385
420
465
515
570
630
TABLE 196
Full Load Amperes
Heater
Element
Cat. No.
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
Cat. No.
592-TPD200
184 A
64
72
74
85
87
96
107
116
128
139
153
168
184
200
215
Cat. No.
592-TPD300
304 A
125
142
155
172
188
205
225
250
275
305
Cat. No.
592-TPD400
496 A
115
127
140
155
170
186
205
215
145
270
296
330
360
400
440
480
520
NEMA Size 6
Cat. No.
592-TPD630
608 A
195
220
239
260
285
315
340
375
410
450
495
540
590
640
Heater
Element
Cat. No.
JJ14
JJ13
JJ12
JJ11
JJ10
JJ9
JJ8
JJ7
JJ6
JJ5
JJ4
JJ3
JJ2
JJ1
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J70
J71
J72
J73
J74
J75
J76
J77
TABLE 198
Full Load Amperes
Size 40 A
0.22
0.24
0.27
0.30
0.33
0.36
0.40
0.44
0.48
0.53
0.58
0.65
0.71
0.78
0.87
0.95
1.05
1.16
1.28
1.41
1.55
1.70
1.87
2.06
2.27
2.51
2.78
3.07
3.38
3.72
4.10
4.52
4.98
5.49
6.04
6.66
7.35
8.13
8.96
9.90
10.9
12.0
13.2
14.6
16.1
18.6
20.9
22.8
25.1
28.5
33.0
35.5
38.5
42.0
Size 68 A
9.03
9.95
11.0
12.3
13.8
15.3
17.1
18.8
21.1
23.5
26.0
29.1
33.5
36.0
39.5
44.0
50.0
56.0
61.0
67.0
70.0
Size 120 A
24.5
29.9
33.0
35.0
39.5
44.0
47.5
54
59
65
72
78
87
95
105
118
126
Size 184 A
42.0
48.5
55
62
68
75
81
90
98
108
120
131
148
160
179
198
1-177
Bulletin_Eutectic_Alloy_Overload_Relays_3.qxd
05/02/2004
19:28
Page 1-178
Heater Element
Cat. No.
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W41
W42
W43
W44
W45
W46
W47
W48
W49
TABLE 547
Heater Element
Cat. No.
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
1-178
Bulletin_600.qxd
05/02/2004
19:33
Page 1-179
Bulletin 600
Bulletin 600
Table of Contents
Accessories . . . . . . . . . 1-180
Modifications . . . . . . . 1-180
Approximate
Dimensions . . . . . . . . . 1-180
Standards Compliance
and Certifications
UL Listed Enclosed
Products (File No. E14841;
Guide No. NLRV)
UL Open Style
Products (File No. E14841;
Guide No. NLRV2)
CSA Certified LR1234
American Bureau of Shipping
CE Marked (Per 60947)
y Hazardous Location:
UL Listed (File No. E10314)
CSA (LR11924)
Your order must include: 1) Cat. No. of the switch, 2) Cat. No. of the heater element(s), and 3) if required, Cat. No. of any accessories.
Ratings
Single Pole 1 HP 115230V AC, 1 HP 277V AC, Open Type
without Enclosure or Type 1 General Purpose Enclosure
Two Pole 1 HP 115230V AC, 1 HP 277V AC, Open Type
without Enclosure or Type 1 General Purpose Enclosure, 3/4 HP
115230V DC
Type 4
Watertight Enclosure
Cat. No.
600-TCX5
600-TEX5
600-TCD7
600-TCA7
600-TED7
600-TEA7
600-TAX9
600-TQX9
600-TCX9
Switch with Neon Pilot Light and Hand-Off-Auto Selector Switch (115 or 230V, AC only)
600-TEX9
600-TOX4
600-TOX5
600-TOX49
600-TOX149
1-Pole
2-Pole
2-Pole
600-TOX216
600-TOX109
600-TOX110
Toggle Type
2-Pole 115V
2-Pole 230V
Toggle Type
2-Pole
Toggle Type
Key Type
2-Pole
2-Pole
Toggle Type
2-Pole
Toggle Type
2-Pole
Toggle Type
2-Pole
Toggle Type
2-Pole
Toggle Type
Key Type
Type 1
General Purpose
Enclosure
Surface Mounting
Cat. No.
Switch Only
600-TAX4
600-TQX4
600-TAX5
600-TQX5
600-TAX49
600-TQX49
600-TAX149
Open Type
Without Enclosure
Includes Legend Plate
Cat. No.
1-Pole
2-Pole
2-Pole
1-Pole
Key Type
Lever Type
Type 1
General Purpose
Enclosure
Flush Mounting
Includes Flush Plate
but not Switch Box
Stainless Steel
Flush Plate
Cat. No.
Description
Toggle Type
600-TAX216
600-TQX216
600-TAX109
600-TQX109
600-TAX110
600-TQX110
Switch with Incandescent Pilot Light
600-TAX142
600-TQX142
600-TAX145
600-TAX10
600-TCX10
Two Switch Units in One Enclosure Neon Pilot Light on Both Units (115 or 230V)
600-TAX144
Two Speed Switch
600-TQX144
600-TAX298
600-TQX293
600-TEX10
600-N12
600-N14
2-Pole
For use with Bulletin 800H, Type 7 and 9, Series C or later bases. See page 10-153 for Base Listings.
1-179
Bulletin_600.qxd
05/02/2004
19:33
Page 1-180
Bulletin 600
Description
Pilot Light Replacement Bulb
Incandescent (Mfg. Designation #120
PSB-120V)
Note: Pilot lights as used on Bulletin
600 switches indicate whether the
motor is running only if the switch is
used to control the motor directly. If a
thermostat, pressure switch or some
other pilot device controls the
operation of the motor, the pilot light
on the Bulletin 600 switch merely
indicates whether the power is ON or
OFF.
NEMA
Enclosure Type
Modifications Factory-Installed
Cat. No.
4, 7 and 9
800S-N60
Note: All single unit devices are provided with one 3/4 in (19 mm)
pipe tap on the bottom. By reversing the switch base, the pipe tap
can be located on the top.
All dual units are provided as standard with one 3/4 in (19 mm) pipe
tap on top and two on the bottom with 2 threaded plugs included. If
1/2 in (12.7 mm) openings are required, reducers should be used.
Drain In order to install a drain on single unit devices (i.e. Cat.
No. 600-TEX5) an additional conduit opening is required. See
Conduit Openings above.
Sealing Well with Integral Flange Seal for Type 3, 7 and 9 To
order this option insert the letter R at the end of the listed Cat. No.
Example: Cat. No. 600-TEX5R.
Locking Attachment
(For Toggle Operated Only)
1
(Switches in the
Type 4 and Type
7 and 9
enclosures are
supplied as
standard with
provisions for
locking in the
OFF or ON
position.)
600-N1
7 and 9
800H-NP21
3, 7, and 9
800H-NP20
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not
intended to be used for manufacturing purposes.
Drain
(For 3/4 in. (19 mm) Conduit Opening)
Flange Seal
(Provides NEMA Type 3 rating for
outdoor locations in addition to
maintaining NEMA Type 7 and 9
integrity)
Note: An approved drain
Cat. No. 800H-NP21 is required for
condensation when this option is used
(refer to local Electrical Code).
600- TOX4
TOX5
TOX49
Sealing Well
(See applicable codes and laws)
(Not available for use with
Cat. No. 600-TEX5)
Note: When using a sealing well with
integral flange seal for NEMA Type 3
outdoor applications, an approved
drain fitting must be provided (refer to
local Electrical Code).
3, 7, and 9
(With integral
flange seal)
2 wire:
800H-NPRD90
4 wire:
800H-NPRD91
7 and 9
(Without integral
flange seal)
2 wire:
800H-NPD90
4 wire:
800H-NPD91
All other devices with the pilot light option utilize a neon lamp. For
1-180
Cat. Nos.
600- TOX109
TOX110
TOX149
600- TOX216
Bulletin_600.qxd
05/02/2004
19:33
Page 1-181
Bulletin 600
600- TAX4
TAX5
TAX49
Cat. Nos.
600- TAX109
TAX110
TAX149
Cat. Nos.
600- TAX142
TAX144
600- TCX5
600- TAX145
Cat. Nos.
600- TEX45
Cat. Nos.
600- TQX4
600- TQX109
TQX5
TQX110
TQX49
TQX216
Cat. Nos.
600- TCX9
600- TEX9
TCX142
TEX10
Cat. Nos.
600- TQX9
600- TQX144
TQX142
Cat. Nos.
600- TCA7
600- TEA7
TCD75
TED7
1-181
Bulletin_609.qxd
05/02/2004
19:37
Page 1-182
Bulletin 609
Table of Contents
Open Type
without Enclosure
Bulletin 609 manual starting switches are designed for use on motor
starting installations where remote push button control is not required
and where undervoltage protection is not needed. The motor is started
at full line voltage, and thermal type overload protection is provided.
Bulletin 609RS manual starting switches are designed for manually
reversing AC polyphase motors; the Bulletin 609TS manual switches
are designed for operating 2-speed, separate winding wye connected
motors. These switches incorporate two of the standard Bulletin 609
manual starting switches mounted on a common base plate. A
mechanical interlock is provided to prevent both switches from being
closed at the same time.
Standards and
Certifications
See below.
Your order must include: 1) Cat. No. of the manual starting switch, 2) Cat. No. of the heater element(s), and 2) if required, Cat. No. of any
accessories.
1-182
y Hazardous Location:
UL Listed (File No. E10314)
CSA Certified (LR 11924)
Bulletin_609.qxd
05/02/2004
19:37
Page 1-183
Bulletin 609
Type
of
Operator
Push
Button
Open Type
without
AC,
Enclosure
50 Hz
DC
460V 380V 115V 230V
Size 115V 200V 230V 575V
Cat. No.
Cat. No.
415V
125V
250V
0
1
2
609-AOX
609-AAX
1
2
3
609-BOX
609-BAX
609-XOX
609-XAX
1P
3
5
609-AOW
609-AAW
0
3
3
5
5
1
7-1/2 7-1/2
10
10
609-BOW
609-BAW
609T-AOX
609T-AAX
0
1
2
609T-BOX
609T-BAX
1
2
3
1P
3
5
609T-XOX
609T-XAX
609T-AOW
609T-AAW
0
3
3
5
5
609T-BOW
609T-BAW
1
7-1/2 7-1/2
10
10
609D-AOZ
609D-AAZ
0
1
1-1/2
609D-BOZ
609D-BAZ
1
1-1/2
2
0
1
1-1/2 609DT-AOZ 609DT-AAZ
609DT-BOZ 609DT-BAZ
1
1-1/2
2
Bulletin 609RS Manual Reversing Switches
AC,
60 Hz
Phase
1
Toggle
Lever
Type 1
General
Purpose
Enclosure
Surface
Mounting
3
Push
Button
DC
Toggle
Lever
DC
Push
Button
Toggle
Lever
Push
Button
Toggle
Lever
Type 4/4X
Watertight,
CorrosionResistant
Type 12
Dusttight Enclosure
Industrial FiberglassReinforced
Use
Enclosure Polyester
Cat. No.
Cat. No.
609-AJX
609-ACX
609-BJX 609-BCX
609-XJX
609-XCX
609-AJW 609-ACW
609-BJW 609-BCW
609D-ACZ
609D-BCZ
Hazardous Locations
Type 3R, 7
Type 7 & 9
& 9
Enclosure
Enclosure
Class I,
Class I,
Groups C & Groups C &
D
D
Class II,
Class II,
Groups E, F Groups E, F
&G
&G
Divisions Divisions
1&2
1&2
Cat. No.
609-AEX
609-BEX
609-XEX
609-AEW
609-BEW
609D-AEZ
609D-BEZ
Cat. No.
609-AHX
609-BHX
609-XHX
609-AHW
609-BHW
609D-AHZ
609D-BHZ
0
1
0
1
3
3
7-1/2 7-1/2
3
3
7-1/2 7-1/2
5
10
5
10
5
10
5
10
Bulletin
609-AOW21 609-AAW21
609-BOW21 609-BAW21
609T-AOW21 609T-AAW21
609T-BOW21 609T-BAW21
609TS Manual 2-Speed Switches
0
1
0
1
3
3
7-1/2 7-1/2
3
3
7-1/2 7-1/2
5
10
5
10
5
10
5
10
609-AOW22
609-BOW22
609T-AOW22
609T-BOW22
609-AAW22
609-BAW22
609T-AAW22
609T-BAW22
Type 1 General Purpose Flush Mounting Enclosures with Pull Box are also available. Order as follows. Change the second letter of the listed Cat. No. from A
to L. Example: Cat. No. 609-ALX. For a stainless steel flush plate, change the second letter of the listed Cat. No. from A to Q.
Example: Cat. No. 609-AQX.
DC Manual Starters are not UL Listed.
Fiberglass-Reinforced Polyester Hubs are included with each starter.
These enclosures include a cover gasket and drain. It is recommended that a breather also be installed.
Breather
Drain
Breather-Drain Combination
1-183
Bulletin_609.qxd
05/02/2004
19:37
Page 1-184
Bulletin 609
Cat. No.
609-N10
609-N20
609-N40
609-N60
Suffix Code
D4
A4
B4
C4
Replacement lamp is ANSI part number B2A (NE-51H), Cat. No. 609-N9.
Fusing
The Bulletin 609 is suitable for general installation in accordance with the local Electrical Code.
Group Fusing
The Bulletin 609 Sizes 0 and 1 in Type 1, 4X and 12 enclosures are UL Listed for group fusing with Class J fuses only. See chart below for
maximum fuse ratings.
Full Load Current of Smallest
Motor Amperes (A)
0.452.99
3.006.49
6.5018.0
1-184
480600V
30
30
Bulletin_609U.qxd
05/02/2004
19:41
Page 1-185
Bulletin 609U
Bulletin 609U
y Contact position indicator
y Locking features
y Wide range of enclosures:
open type, enclosure Types 1, 4/4X, 3R 7&9 and 12
y Undervoltage protection
Bulletins 609U and 609TU are the same as the standard Bulletin 609 Manual Starters
except for the addition of Undervoltage Protection. These starters provide full line
voltage starting, thermal overload protection, as well as Undervoltage Protection.
Typical applications are on woodworking machinery, metal sawing machines, and many
other machine tools where Undervoltage Protection is needed to meet safety
standards. The Undervoltage Protection is accomplished by an electromechanical
solenoid which is energized whenever line voltage is present. The solenoid is designed
to mechanically open the starter contacts upon power failure, and keep them open
even if power is returned to the unit. Only after the starter has been manually reset by
pushing the operator to the stop position, can the starter be re-energized.
Open Type Bulletin 609U and 609TU switches can replace the Bulletin 609 switches in
Types 1 and 12 enclosures of the latest construction without any field modification of
the enclosure.
Table of Contents
Product Overview . . . this page
Product Selection . . . 1-186
Accessories . . . . . . . . . 1-187
Typical Wiring
Diagram . . . . . . . . . . . . 1-187
Approximate
Dimensions . . . . . . . . . 1-188
Standards and
Certifications
See below.
Your order must include: 1) Cat. No. of the manual starting switch with undervoltage protection, 2) Cat. No. of the heater element(s), and 2) if
required, Cat. No. of any accessories.
y Hazardous Location:
UL Listed (File No. E10314)
CSA Certified (LR 11924)
1-185
Bulletin_609U.qxd
05/02/2004
19:41
Page 1-186
Bulletin 609U
Type Of
Operator Phase
1
Push
Button
3
1
Toggle
Lever
3
Size
0
1
1P
0
1
0
1
1P
0
1
115V
1
2
3
200V
3
7-1/2
1
2
3
3
7-1/2
230V
2
3
5
3
7-1/2
2
3
5
3
7-1/2
50 Hz
380 460
415V 575V
5
5
10
10
5
5
10
10
Open Type
without
Enclosure
Type 1
General
Purpose
Enclosure
Surface
Mounting
Cat. No.
609U-AO
609U-BO
609U-XO
609U-AO
609U-BO
609TU-AO
609TU-BO
609TU-XO
609TU-AO
609TU-BO
Cat. No.
609U-AA
609U-BA
609U-XA
609U-AA
609U-BA
609TU-AA
609TU-BA
609TU-XA
609TU-AA
609TU-BA
Hazardous Locations
Type 7 & 9
Type 3R, 7 & 9
Enclosure
Class I,
Enclosure
Groups C & D Class I, Groups C
Class II,
&D
Class II, Groups
Groups
E, F & G
E, F & G
Divisions 1 Divisions 1 & 2
&2
Type 12
Dusttight,
Industrial
Use
Enclosure
Type 4/4X
Watertight,
CorrosionResistant
Enclosure
FiberglassReinforced
Polyester
Cat. No.
609U-AJ
609U-BJ
609U-XJ
609U-AJ
609U-BJ
Cat. No.
609U-AC
609U-BC
609U-XC
609U-AC
609U-BC
Cat. No.
609U-AE
609U-BE
Cat. No.
609U-AH
609U-BH
609U-AE
609U-BE
609U-AH
609U-BH
Common Control
Separate Control
24V
XWJ
Hz
Hz
Hz
Hz
110115V
XS
XE
XWS
115120V
XD
XWD
200208V
XH
XWH
220230V
XP
XF
XWP
230240V
XA
XWA
240V
XG
XWT
277V
XWF
50
60
50
60
Hz
Hz
Hz
Hz
24V
K
WJ
110V
S
E
115
120V
200
208V
220
230V
P
F
230
240V
240V
VP
277V
WF
380V
VN
415V
WL
440
460V
Q
N
460
480V
500V
WM
550V
R
WC
575
600V
Type 1 General Purpose Flush Mounting Enclosures with Pull Box are also available. Order as follows. Change the second letter of the listed Cat. No. from A
to L. Example: Cat. No. 609U-ALX. For a stainless steel flush plate, change the second letter of the listed Cat. No. from A to Q. Example: Cat. No.
609U-AQX.
Fiberglass-Reinforced Polyester Hubs are included with each starter.
These enclosures include a cover gasket and drain. It is recommended that a breather also be installed.
Breather
Drain Only
Breather-Drain Combination
1-186
Bulletin_609U.qxd
05/02/2004
19:41
Page 1-187
Bulletin 609U
Accessories
Pilot Light Kits
Kits are available for field installation of pilot lights in Type 1 General Purpose surface or flush mounting enclosures. A clear lens is provided
as standard. Pilot lights are not available for Bulletin 609RS or 609TS manual starters.
Volts (V)
120
240
480
600
Cat. No.
609-N10
609-N20
609-N40
609-N60
NEMA Type
Type 1
Group Fusing
The Bulletin 609U and 609TU Sizes 0 and 1 in Type 1, 4/4X and 3R/12 enclosures are UL Listed for group fusing with Class J fuses only. See
chart below for maximum fuse ratings.
Maximum Fuse Ratings (A)
Nominal System Voltages
120240V
30
60
100
480600V
30
30
1-187
Bulletin_609-609U_and_609RS-609TS.qxd
05/02/2004
19:45
Page 1-188
NEMA Type 1
Surface Mounting
1-188
Bulletin_609-609U_and_609RS-609TS.qxd
05/02/2004
19:45
Page 1-189
NEMA Type 12
NEMA Type 1
1-189
Bulletin_1494V_1_Disconnect_Switches.qxd
05/02/2004
19:50
Page 1-190
Bulletin 1494V
Table of Contents
Standards and
Certifications
y UL Listed (File No. E47426)
per UL 98
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 4
y CE Certified
1494V DR
a
a
Code
1494V
Disconnect Switch
Description
Variable-Depth Flange mounted
Code
DN
DH
DJ
DR
Fusing
Description
Non-fusible
Class H fuse clips
Class J fuse clips
Class R fuse clips
1-190
233 A B FF
c
d
c
Code
30
60
100
200
400
600
233
236
633
636
263
266
261
663
666
661
616
611
612
621
622
624
642
644
604
606
d
Code
A
B
C
D
E
F
FF
G
GG
Bulletin_1494V_1_Disconnect_Switches.qxd
05/02/2004
19:50
Page 1-191
Bulletin 1494V
30
R
1494V-DR233
30
H, J 1494V-DH633
1494V-DR633
30
R
1494V-DN30
30
3
7.5
7.5
15
20
2
3
3
5
5.5
11
15
60
H
1494V-DH236
60
R
1494V-DR236
60
H, J 1494V-DH636
60
R
1494V-DR636
1494V-DH263
30
H
30
R
1494V-DR263
30
H, J 1494V-DH663
30
R
1494V-DR663
60
H
1494V-DH266
1494V-DN60
60
3
7.5
7.5
15
20
2
3
3
5
5.5
11
15
60
R
1494V-DR266
60
H, J 1494V-DH666
1494V-DR666
60
R
100
H, J 1494V-DH661
100
100
R
1494V-DR661
60
H, J 1494V-DH616
60
R
1494V-DR616
100
25
30
60
75
20
22
45
55
100
100
H, J 1494V-DH611 1494V-DN100
100
100
R
1494V-DR611
1494V-DH612
200
J
100
H, J 1494V-DH621
1494V-DR621
100
R
200
5060
60
125
150
40
48
90
110
200
200
H, J 1494V-DH622 1494V-DN200
200
200
R
1494V-DR622
400
J
1494V-DH624
200
H, J 1494V-DH642
200
R
1494V-DR642
400
400
H, J 1494V-DH644
400
75
125
250
350
50
90
185
257
1494V-DN400
400
400
R
1494V-DR644
400
H,
J
1494V-DH604
400
R
1494V-DR604
1494V-DH606
600
600
H
600
600
R
1494V-DR606 1494V-DN600
600
150
200
400
500
50
150
295
375
600
J
1494V-DJ606
Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
Class J fuses bolt directly to the switch and trailer fuse block.
Use 1494R-N10 lug kit for wiring to the disconnect switch. Use 1494R-N11 lug kit when wiring separately mounted fuse blocks (1491-R621, 1491-N621).
Kit Accessories
Bulletin 1494V Kit Accessories Field Installed
Description
Longer Connecting Rod 9 1/8 in (min.) 21 5/8 in (max.)
Disconnect Handle Stainless Steel
Disconnect Handle Non-Metallic
Wire Connecting Lugs Line and Load Side
Protective Fuse Cover with Door
Auxiliary Contact
1 N.O.
2 N.O.
1 N.C.
2 N.C.
Suffix Code
A
B
C
D
E
F
FF
G
GG
30 A
A
A
A
A
A
A
A
A
A
60 A
A
A
A
A
A
A
A
A
A
Switch Size
100 A
200 A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
400 A
A
A
A
A
A
A
A
A
A
600 A
A
A
A
A
A
A
A
A
A
1-191
Bulletin_1494V_1_Disconnect_Switches.qxd
05/02/2004
19:50
Page 1-192
Bulletin 1494V
75
150
230V
7.5
15
30
60
125
200
AC 1
460V
15
30
60
125
250
400
575V
20
50
75
150
350
500
IEC Utilization
Category AC-23
Maximum Rating kW
3, 50 Hz
DC
115
2
3
230
3
10
250
5
10
20
40
50
50
220240V
5.5
11
22
45
90
150
380440V
11
22
45
90
185
295
500600V
15
37
55
110
257
375
Cat. No.
Switch Only
1494V-DS30
1494V-DS60
1494V-DS100
1494V-DS200
1494V-DS400
1494V-DS600
Also rated operational current for utilization categories AC-20 and AC-21 (IEC 408).
Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
Disconnect Switches are field convertible from right-hand to left-hand flange operation.
50 Hp at 200V AC; 60 Hp at 208V AC.
Connecting Rods
For Class H, J, or R fuses, select the proper fuse clip kit from the
table below.
Disconnect Switch
Size (A)
30, 60, 100, 200
400, 600
Enclosure Depth
Minimum
Maximum
6-3/4 (172)
9-1/8 (232)
9-1/8 (232)
21-5/8 (585)
9 (229)
9-1/4 (235)
9 (229)
21-5/8 (585)
Cat. No.
1494V-RA3
1494V-RA4
Operating Handles
Type 1, 3R, 4,
4X, 12
Description
Non-Metallic
Mounting
Right or Left
Flange
Right Flange
Only
Type 1, 3R,
4,12
Painted Metal
Right or Left
Flange
Type 4, 4X
Stainless
Steel
Right or Left
Flange
Cat. No.
1494V-FS30
1494V-FS60
100
200
400
1494V-FS100a
1494V-FS200
1494V-FS400
600
1494V-FS600
1494V-RB1
1494V-RB2
Enclosure depth is measured from the top of the flange to the disconnect
switch mounting surface (mm).
Two per installation required.
Handle
Type
Disconnect
Switch Size (A)
Cat. No.
1494F-P1
400, 600
1494V-R2
1494F-M1
1494V-H2
1494F-S1
1494V-W2
a The 100 A disconnect size with 60 A fuse clips, also requires Adapter Kit,
1401-N170.
For use with Class J fuses that bolt directly to the switch (fuse clips not
required).
The 600 A disconnect size with 400 A fuse clips, requires Trailer Fuse Block
Kit, 1494V-FS400.
For 600V Class H fuses, use Single Pole Fuse Block 1491-N621-(3)
required. For 600V Class R fuses, use Single Pole Fuse Block 1491-R621(3) required. (Use 1494R-N11 Lug Kit for wiring to the disconnect switch.)
H, J
H, R
60
30
60
100
100
200
200
400
400
600
600
30
60
30
60
100
200
400
600
100
200
400
600
Cat. No.
1401-N41
1401-N42
1401-N43
1401-N44
1401-N45
1494F, 1494G, 1401-N46
1494M, 1494R,
7
1494V
1401-N50
Disconnect
1401-N51
Switches
1401-N52
1401-N53
1401-N54
1401-N55
1-192
11
Bulletin_1494F.qxd
05/02/2004
19:53
Page 1-193
Bulletin 1494F
Table of Contents
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-211
Standards and
Certifications
y UL Listed (File No. E47426)
per UL 98
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 4
y CE Certified
Continuos
Current
Rating
(A)
600V AC
250V DC
30
60
100
200
230V
7.5
15
30
60
460V
15
30
60
100
575V
20
40
75
100
20
22
45
55
1494F-NF100 1494F-NFL100
40
45
75
75
1494F-NF200 1494F-NFL200
Non-Fusible
Open Type
without Enclosure
Flange Construction
Right Hand
Left Hand
Cat. No.
1494F-N30
1494F-N60
1494F-N100
1494F-N200
Cat. No.
1494F-NL30
1494F-NL60
1494F-NL100
1494F-NL200
Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
60
100
200
Fuse Clip
Rating (A)
30
60
30
60
100
100
200
200
400
Class R
250V
Cat. No.
1494F-R233
1494F-R263
1494F-R266
1494F-R216
1494F-R211
1494F-R221
1494F-R222
1494F-R242
600V
Cat. No.
1494F-R633
1494F-R663
1494F-R636
1494F-R666
1494F-R616
1494F-R611
1494F-R621
1494F-R622
1494F-R642
Class J
600V
Cat. No.
1494F-J633
1494F-J663
Class H
250V
Cat. No.
1494F-C233
1494F-C263
1494F-J666
1494F-J616
1494F-J611
1494F-J621
1494F-J622
1494F-J642
1494F-C266
1494F-C216
1494F-C211
1494F-C221
1494F-C222
1494F-C242
Class H and E
600V
Cat. No.
1494F-C633
1494F-C663
1494F-C636
1494F-C666
1494F-C616
1494F-C611
1494F-C621
1494F-C622
1494F-C642
1-193
Bulletin_1494G_1494GX_1494GY.qxd
05/02/2004
19:58
Page 1-194
Bulletin 1494G/1494GX/1494GY
1494G B
a
6 98 203W 414
a
Code
1494G
1494GY
1494GX
Bulletin Number
Description
Enclosed Disconnect Safety
Switch in standard-size enclosure
(30600 A)
Enclosed Disconnect Safety
Switch in large-size enclosure
(30200A)
Enclosed Disconnect Safety
Switch in extra large-size enclosure
(30100 A)
b
Code
B
C
D
E
F
G
Switch Ratings
Description
30 A
60 A
100 A
200 A
400 A
600 A
Enclosure Type
Code
Description
Type 3R/4/12: Rainproof, watertight,
F
dusttight, painted metal enclosure with
screw fasteners and non-metallic handle
Type 4/4X: Watertight, corrosion-resistant,
C
stainless steel enclosure with screw
fasteners and non-metallic handle
Type 4/4X: Watertight, corrosion-resistant,
S
non-metallic enclosure with screw
fasteners and non-metallic handle
Type 12: Hazardous location (Class II,
Division 2, Group F+G and Class III
K
Division 1 and 2) painted metal enclosure
with screw fasteners and non-metallic
handle
d
Code
2
3
6
Poles
Description
2-pole, 1
3-pole, 3
6-pole, 3
Code
N
H
J
R
Fusing
Description
Non-fusible
Class H Fuse Clips
Class J Fuse Clips
Class R Fuse Clips
f
Code
Blank
2
6
g
Options (Factory Installed)
Code
Description
Momentary Push Button
1S
(Flange-mounted)
Momentary Push Button
1SB
(Bottom-mounted)
3
3-position Selector Switch
3E
2-position Selector Switch
3EI
2-position Selector Switch (Illuminated)
3-position Selector Switch
3S
(Spring Return)
4
Pilot Light
5
Push-to-test Pilot Light
98
N.O. Auxiliary - Disconnect
99
N.C. Auxiliary - Disconnect
203W
Viewing Window
412
Painted Metal Handle
413
Stainless Steel Handle
414
Protective Fuse Cover
420
1 N.O. and 1 N.C. Interlock
421
2 N.O. and 2 N.C. Interlocks
Specify lens color by adding one of the following letters: R = Red, A = Amber, B = Blue, G = Green
3 pole enclosed switches can accomodate (1) pilot device, 6 pole enclosed switches can accomodate (5) pilot devices
Maximum of (2) auxiliary contacts
1-194
Fuse Voltage
Description
Non-fusible
240V AC/250V DC
600V AC/600V DC
Bulletin_1494G_1494GX_1494GY.qxd
05/02/2004
19:58
Page 1-195
Bulletin 1494G/1494GX/1494GY
Bulletin 1494G/1494GX/1494GY
Table of Contents
Modifications . . . . . . . 1-198
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-212
Stanadards and
Certifications
y cULus Listed (File No.
E227497) per UL 98 and CSA
C22.2 No. 4
y At Motor rated, per UL 508
(30A100A)
240V, Fusible with Class H Fuse Clips, (2-pole, 1 /3-pole, 3 ), standard size enclosure
Continuous
Current
Rating
(A)
600V AC
250V DC
30
60
100
200
400
600
240V AC,
1
Std.
1.5
3
7.5
15
Type 3R/4/12
Painted Metal
Horsepower
240V AC,
3
Max.
3
10
15
15
Std.
3
7.5
15
25
50
75
Max.
7.5
15
30
60
125
200
250V
DC
5
10
20
40
50
50
Type 4/4X
Stainless Steel
2-pole, 1
3-pole, 3
2-pole, 1
Cat. No.
1494G-BF2H2
1494G-CF2H2
1494G-DF2H2
1494G-EF2H2
Cat. No.
1494G-BF3H2
1494G-CF3H2
1494G-DF3H2
1494G-EF3H2
1494G-FF3H2
1494G-GF3H2
Cat. No.
1494G-BC2H2
1494G-CC2H2
1494G-DC2H2
1494G-EC2H2
3-pole, 3
Type 4/4X
Non-metallic
2-pole, 1
3-pole, 3
Cat. No.
Cat. No.
Cat. No.
1494G-BC3H2 1494G-BS2H2 1494G-BS3H2
1494G-CC3H2 1494G-CS2H2 1494G-CS3H2
1494G-DC3H2 1494G-DS2H2 1494G-DS3H2
1494G-EC3H2
1494G-FC3H2
1494G-GC3H2
240V, Fusible with Class H Fuse Clips, (2-pole, 1 /3-pole, 3 ), extra large size enclosure
Continuous
Current
Rating
(A)
600V AC
250V DC
30
60
100
Horsepower
240V AC,
240V AC,
1
3
Std.
1.5
3
7.5
Max.
3
10
15
Std.
3
7.5
15
Max.
7.5
15
30
Type 3R/4/12
Painted Metal
250V
DC
5
10
20
2-pole, 1
3-pole, 3
Type 4/4X
Stainless Steel
2-pole, 1
3-pole, 3
Type 4/4X
Non-metallic
2-pole, 1
3-pole, 3
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
1494GX-BF2H2 1494GX-BF3H2 1494GX-BC2H2 1494GX-BC3H2 1494GX-BS2H2 1494GX-BS3H2
1494GX-CF2H2 1494GX-CF3H2 1494GX-CC2H2 1494GX-CC3H2 1494GX-CS2H2 1494GX-CS3H2
1494GX-DF2H2 1494GX-DF3H2 1494GX-DC2H2 1494GX-DC3H2
240V, Fusible with Class H Fuse Clips, (2-pole, 1 /3-pole, 3 ), large size enclosure
Continuous
Current
Rating
(A)
600V AC
250V DC
30
60
100
200
Horsepower
240V AC,
240V AC,
1
3
Std.
1.5
3
7.5
15
Max.
3
10
15
15
Std.
3
7.5
15
25
Max.
7.5
15
30
60
Type 3R/4/12
Painted Metal
250V
DC
5
10
20
40
Type 4/4X
Stainless Steel
Type 4/4X
Non-metallic
2-pole, 1
3-pole, 3
2-pole, 1
3-pole, 3
2-pole, 1
3-pole, 3
Cat. No.
1494GY-BF2H2
1494GY-CF2H2
1494GY-DF2H2
1494GY-EF2H2
Cat. No.
1494GY-BF3H2
1494GY-CF3H2
1494GY-DF3H2
1494GY-EF3H2
Cat. No.
1494GY-BC2H2
1494GY-CC2H2
1494GY-DC2H2
1494GY-EC2H2
Cat. No.
1494GY-BC3H2
1494GY-CC3H2
1494GY-DC3H2
1494GY-EC3H2
Cat. No.
Cat. No.
240V, Fusible with Class H Fuse Clips, (6-pole, 3 ), standard size enclosure
Continuous Current Rating
(A)
600V AC
250V DC
30
60
100
Horsepower
240V AC, 3
Std.
3
7.5
15
Cat. No.
1494G-BF6H2
1494G-CF6H2
1494G-DF6H2
Cat. No.
1494G-BC6H2
1494G-CC6H2
1494G-DC6H2
Max.
7.5
15
30
Class R and J fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, replace H from the Cat. No. with R.
Example: Cat. No. 1494G-BF2H2 becomes 1494G-BF2R2. To order Class J fuse clips, replace H from the Cat. No. with J. Example: Cat. No. 1494G-BF2H2
becomes 1494G-BF2J2. The same applies to Cat. No. 1494GX and 1494GY.
Type 12 hazardous location enclosure (Class II, Division 2, Group F+G and Class III, Divisions 1 and 2) can be supplied by replacing the F in the listed catalog
number with the letter L. Example: 1494G-BL3H2.
1-195
Bulletin_1494G_1494GX_1494GY.qxd
05/02/2004
19:58
Page 1-196
Bulletin 1494G/1494GX/1494GY
Bulletin 1494G/1494GX/1494GY
Table of Contents
Modifications . . . . . . . 1-198
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-212
Standards and
Certifications
y cULus Listed (File No.
E227497) per UL 98 and CSA
22.2 No. 4
y At Motor rated per UL 508
(30100A)
600V, Fusible with Class H Fuse Clips, (3-pole, 3 ), standard size enclosure
Continuous Current
Rating
(A)
600V AC
250V DC
30
60
100
200
400
600
Horsepower
600V AC
480V AC
Std.
5
15
25
50
100
150
Max.
15
30
60
125
250
400
Std.
7.5
15
30
60
125
200
Max.
20
50
75
150
350
500
250V
DC
5
10
20
40
50
50
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494G-BF3H6
1494G-CF3H6
1494G-DF3H6
1494G-EF3H6
1494G-FF3H6
1494G-GF3H6
Cat. No.
1494G-BC3H6
1494G-CC3H6
1494G-DC3H6
1494G-EC3H6
1494G-FC3H6
1494G-GC3H6
Cat. No.
1494G-BS3H6
1494G-CS3H6
1494G-DS3H6
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494GX-BF3H6
1494GX-CF3H6
1494GX-DF3H6
Cat. No.
1494GX-BC3H6
1494GX-CC3H6
1494GX-DC3H6
Cat. No.
1494GX-BS3H6
1494GX-CS3H6
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494GY-BF3H6
1494GY-CF3H6
1494GY-DF3H6
1494GY-EF3H6
Cat. No.
1494GY-BC3H6
1494GY-CC3H6
1494GY-DC3H6
1494GY-EC3H6
Cat. No.
600V, Fusible with Class H Fuse Clips, (3-pole, 3 ), extra large size enclosure
Continuous Current
Rating
(A)
600V AC
250V DC
30
60
100
Horsepower
600V AC
480V AC
Std.
5
15
25
Max.
15
30
60
Std.
7.5
15
30
Max.
20
50
75
250V
DC
5
10
20
600V, Fusible with Class H Fuse Clips, (3-pole, 3 ), large size enclosure
Continuous Current
Rating
(A)
600V AC
250V DC
30
60
100
200
Horsepower
600V AC
480V AC
Std.
5
15
25
50
Max.
15
30
60
125
Std.
7.5
15
30
60
Max.
20
50
75
150
250V
DC
5
10
20
40
600V, Fusible with Class H Fuse Clips, (6-pole, 3 ), standard size enclosure
Continuous Current
Rating
(A)
600V AC
250V DC
30
60
100
480V AC
Std.
5
15
25
Max.
15
30
60
Horsepower
600V AC
Std.
7.5
15
30
Max.
20
50
75
250V
DC
5
10
20
Type 3R/4/12
Painted Metal
6-pole, 3
Type 4/4X
Stainless Steel
6-pole, 3
Cat. No.
1494G-BF6J6
1494G-CF6J6
1494G-DF6J6
Cat. No.
1494G-BC6J6
1494G-CC6J6
1494G-DC6J6
Class R and J fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, replace H from the Cat. No. with R.
Example: Cat. No. 1494G-BF3H6 becomes 1494G-BF3R6. To order Class J fuse clips, replace H from the Cat. No. with J. Example: Cat. No. 1494G-BF3H6
becomes 1494G-BF3J6. The same applies to Cat. No. 1494GX and 1494GY.
Type 12 hazardous location enclosure (Class II, Division 2, Group F+G and Class III, Divisions 1 and 2) can be supplied by replacing the F in the listed catalog
number with the letter L. Example: 1494G-BL3H2.
1-196
Bulletin_1494G_1494GX_1494GY.qxd
05/02/2004
19:58
Page 1-197
Bulletin 1494G/1494GX/1494GY
Bulletin 1494G/1494GX1494GY
Table of Contents
Modifications . . . . . . . 1-198
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-212
Standards and
Certifications
y cULus Listed (File No.
227497) per UL 98 and CSA
22.2 No. 4
y At Motor rated per UL 508
(30A100A)
Horsepower
600V AC
480V AC
Std.
5
15
25
50
100
150
Max.
20
50
60
125
250
400
Std.
7.5
15
30
60
125
200
Max.
30
60
75
150
350
500
250V
DC
5
10
20
40
50
50
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494G-BF3N
1494G-CF3N
1494G-DF3N
1494G-EF3N
1494G-FF3N
1494G-GF3N
Cat. No.
1494G-BC3N
1494G-CC3N
1494G-DC3N
1494G-EC3N
1494G-FC3N
1494G-GC3N
Cat. No.
1494G-BS3N
1494G-CS3N
1494G-DS3N
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494GX-BF3N
1494GX-CF3N
1494GX-DF3N
Cat. No.
1494GX-BC3N
1494GX-CC3N
1494GX-DC3N
Cat. No.
1494GX-BS3N
1494GX-CS3N
Type 3R/4/12
Painted Metal
3-pole, 3
Type 4/4X
Stainless Steel
3-pole, 3
Type 4/4X
Non-metallic
3-pole, 3
Cat. No.
1494GY-BF3N
1494GY-CF3N
1494GY-DF3N
1494GY-EF3N
Cat. No.
1494GY-BC3N
1494GY-CC3N
1494GY-DC3N
1494GY-EC3N
Cat. No.
Horsepower
600V AC
480V AC
Std.
5
15
25
Max.
20
50
60
Std.
7.5
15
30
Max.
30
60
75
250V
DC
5
10
20
Horsepower
600V AC
480V AC
Std.
5
15
25
50
Max.
20
50
60
125
Std.
7.5
15
30
60
Max.
30
60
75
150
250V
DC
5
10
20
40
480V AC
Std.
5
15
25
Max.
15
30
60
Horsepower
600V AC
Std.
7.5
15
30
Max.
20
50
75
250V
DC
5
10
20
Type 3R/4/12
Painted Metal
6-pole, 3
Type 4/4X
Stainless Steel
6-pole, 3
Cat. No.
1494G-BF6N
1494G-CF6N
1494G-DF6N
Cat. No.
1494G-BC6N
1494G-CC6N
1494G-DC6N
Type 12 hazardous location enclosure (Class II, Division 2, Group F+G and Class III, Divisions 1 and 2) can be supplied by replacing the F in the listed catalog
1-197
Bulletin_1494G_1494GX_1494GY.qxd
05/02/2004
19:58
Page 1-198
Bulletin 1494G/1494GX/1494GY
Enclosure Type
Suffix
Code
30
60
-1S
-1SB
-3
-3S
-3E
-3EI
Pilot Light
-4
-5
-98
Description
-99
-203W
-412
-413
-414
-420
-421
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
S
S
A
A
A
A
S
S
A
A
A
A=Available Option
S=Standard
3 pole enclosed switches can accomodate (1) pilot device, 6 pole enclosed switches can accomodate (5) pilot devices
Specify lens color by adding one of the following letters: R = Red, G = Green, A = Amber, B = Blue
Maximum of (2) auxiliary contacts
1-198
600
Bulletin_1494V_2_Circuit_Breakers.qxd
05/02/2004
20:00
Page 1-199
Bulletin 1494V
Table of Contents
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-210
Standards and
Certifications
y UL Listed (File No. E47426)
per UL 98
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 4
Operating Mechanism
Cat. No.
1494V-C125
1494V-C150
1494V-C250A
1494V-C250
1494V-C400
Kit Accessories
Bulletin 1494V Kit Accessories Field Installed
Description
Longer Connecting Rod 9 1/8 in (min.) 21 5/8 in (max.)
Disconnect Handle Stainless Steel
Disconnect Handle Non-Metallic
1 N.O.
2 N.O.
1 N.C.
2 N.C.
Suffix Code
A
B
C
F
FF
G
GG
30 A
A
A
A
A
A
A
A
60 A
A
A
A
A
A
A
A
Switch Size
100 A
200 A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
400 A
A
A
A
A
A
A
A
600 A
A
A
A
A
A
A
A
1-199
Bulletin_1494V_2_Circuit_Breakers.qxd
05/02/2004
20:00
Page 1-200
Bulletin 1494V
Operating Mechanism
Cat. No.
1494V-M41
1494V-M40
1494V-M51
1494V-M50
1494V-M60
Connecting Rods
Approximate dimensions are in inches (millimeters). Approximate dimensions are not intended for manufacturing purposes.
Circuit Breaker
Frame Size (A)
125, 150, 250, 400
Enclosure Depth
Minimum
6-3/4 (172)
9-1/8 (232)
Maximum
9-1/8 (232)
21-5/8 (585)
Cat. No.
1494V-RA3
1494V-RA4
Operating Handle
Handle Type
Type 1, 3R, 4, 4X, 12
Type 1, 3R, 4,12
Type 4, 4X
1-200
Description
Non-Metallic
Painted Metal
Stainless Steel
Mounting
Right or Left Flange
Right or Left Flange
Right or Left Flange
Circuit Breaker
Frame Size (A)
125, 150, 250, 400
125, 150, 250, 400
125, 150, 250, 400
Operating Handle
Cat. No.
1494F-P1
1494F-M1
1494F-S1
Bulletin_1494D.qxd
05/02/2004
20:03
Page 1-201
Bulletin 1494D
Table of Contents
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-209
Approximate
Dimensions . . . . . . . . . 1-211
Standards and
Certifications
y UL Recognized (File No.
E3125) per UL 508
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 14
Brand
Cutler-Hammer
Operator
Slide or Bail
Cat. No.
1494D-N4
Cat. No.
1494D-N40
1494D-N50
1494D-N60
1494D-N31
1494D-N41
1494D-N41T
1494D-N43
1494D-N5
1494D-N3
1-201
Bulletin_1494V_3_Operating_Mechs.qxd
05/02/2004
20:05
Page 1-202
Bulletin 1494V
Table of Contents
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-209
Approximate
Dimensions . . . . . . . . . 1-210
Standards and
Certifications
y UL Recognized (File No.
E3125) per UL 508
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 14
Remote Drive
Main Drive
Operating
Dual Operating
Mechanism Mechanism (Includes
Operating Handle)
Description
Remote Operating Mechansims Allows the handle to be mounted above or below the disconnect switch or circuit breaker.
Dual Operating Mechanisms Permits the control of (2) disconnect switches or circuit breakers utilizing a common handle.
Operation Both the Remote and Dual Operating Mechanisms consist of (2) components: a main drive mechanism (which includes the
handle) and a remote drive mechanism. To obtain a functional device, these components must be properly combined with a connecting link
(supplied by the customer), disconnecting means and connecting rod.
Enclosure
Type
Size (A)
Disconnect Switch
Circuit Breaker
Frame Designation
Brand
400, 600
Cutler-Hammer
400, 600
Cutler-Hammer
Two 150 A
Cutler-Hammer
Two 150 A
Cutler-Hammer
Type 1, 3, 3R, 12
Remote
Type 4
Mounting
Right
Left
Right
Left
Right
Cat. No.
1494V-H5
1494V-HL5
1494V-H8
1494V-HL8
1494V-H10
Left
1494V-HL10
Right
Left
Right
Left
Right
1494V-W5
1494V-WL5
1494V-W8
1494V-WL8
1494V-W10
Left
1494V-WL10
Right
1494V-H50
Left
1494V-HL50
Right
Left
Right
1494V-H95
1494V-HL95
1494V-W50
Left
1494V-WL50
Right
Left
1494V-W95
1494V-WL95
Includes Main and Remote Drive Mechanisms. Does not include rectangular bar stock (1/4 inch) 6.35 mm x (5/8 inch) 15.8 mm connecting bar between
1-202
Bulletin_1494M.qxd
05/02/2004
20:07
Page 1-203
Bulletin 1494M
Table of Contents
Accessories . . . . . . . . . 1-204
Specifications . . . . . . . 1-208
Approximate
Dimensions . . . . . . . . . 1-210
Standards and
Certifications
y UL Recognised (File No.
E3125) per UL 508
y CSA Certified (File No.
LR1234) per
CSA C22.2 No. 14
Description
Operation The remote mechanism consists of (2) components a disconnect switch and the operating mechanism. To obtain a functional
device, these components must be properly combined with a connecting link (supplied by the customer). This method allows the user to
determine specific distances required between the disconnect switch and the operating mechanism.
Note: The operating mechanism can only be mounted below the switch.
Product Selection
Fusible and Non-Fusible Disconnect Kits
y Non Fusible disconnect switch includes: switch, operating mechanism and handle
y Fusible disconnect switch includes: switch, operating mechanism and handle (select the proper Fuse Block Adapter Plate with Fuse Clips
from the table below)
y Line and Load lugs located in the Accessories section on page 1-204
Complete Disconnect Switch Kit for Type 1 and Type 12
Continuous
Current
Rating
(A)
600V AC
250V DC
30
60
100
200
AC 1
115V
2
3
230V
3
10
IEC Applications
Maximum kW (AC23)
DC
3, 50 Hz
220 380 500
125V 250V 240V 440V 600V
3
5
5.5
11
15
10
5
11
22
30
10
20
22
45
55
20
40
45
75
75
Cat. No.
1494M-NFL30
1494M-NFL60
1494M-NFL100
1494M-NFL200
Cat. No.
1494M-N30
1494M-N60
1494M-N100
1494M-N200
Cat. No.
1494M-NL30
1494M-NL60
1494M-NL100
1494M-NL200
Does not include rectangular bar stock 1/4 in. (6.35 mm) x 5/8 in.(15.8 mm) connecting bar between switch and remote operating mechanism and handle to be
provided by user.
Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line.
60
100
200
Fuse Clip
Rating (A)
30
60
60
100
100
200
200
400
250V
Cat. No.
1494F-R233
1494F-R263
1494F-R266
1494F-R216
1494F-R211
1494F-R221
1494F-R222
1494F-R242
600V
Cat. No.
1494F-R633
1494F-R663
1494F-R636
1494F-R666
1494F-R616
1494F-R611
1494F-R621
1494F-R622
1494F-R642
Class J
600V
Cat. No.
1494F-J633
1494F-J663
1494F-J666
1494F-J616
1494F-J611
1494F-J621
1494F-J622
1494F-J642
Class H
250V
600V
Cat. No.
Cat. No.
1494F-C233
1494F-C633
1494F-C263
1494F-C663
1494F-C636
1494F-C266
1494F-C666
1494F-C216
1494F-C616
1494F-C211
1494F-C611
1494F-C221
1494F-C621
1494F-C222
1494F-C622
1494F-C242
1494F-C642
1-203
Bulletin_1494.qxd
06/02/2004
16:57
Page 1-204
Bulletin 1494
Description
1 N.O. Contact
Auxiliary Contacts
1 N.C. Contact
Cat. No.
1495-N21
Cat. No.
1495-N23
1494V Disconnect
Switch
30A600A
595-A
1 N.C. Contact
1494V Disconnect
Switch
30A600A
595-B
1494V Disconnect
Switch
400 A600 A
595-N1
Auxiliary Contacts
1 N.O. Contact
1 N.C. Contact
1 N.O. and 1 N.C. Contact
1-204
1494R Disconnect
Switch 30 A, 60 A
1494R Disconnect
Switch 100 A, 200 A
895-A1
895-B1
895-C1
895-M11
895-M12
895-A2
895-B2
895-C2
895-M21
895-M22
1495-N34
Cat. No.
1495-N33
1495-N9
1 N.O. Contact
1494D, 1494V
Circuit Breakers
Auxiliary Contacts
Cat. No.
1495-N8
1494G Disconnect
Switch
1495-N35
1495-N36
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-205
Bulletin 1494
600
Ground Connectors
600 A
1494F, 1494G,
1494M, 1494R,
1494V Disconnect
Switches
1494G
1491 Fuse Blocks
1494F, 1494G,
1494M, 1494R,
1494V Disconnect
Switches
Cat. No.
1494R-N1
1494R-N2
1494R-N3
1494R-N10
1494R-N14
1494R-N11
599-GR1
599-GR2
599-GR3
H, J
30
60
30
60
100
100
200
200
400
400
600
600
30
60
H, R
Protective Fuse Covers
100
200
400
600
1401-N42
1401-N43
1401-N44
1401-N45
1401-N46
1401-N50
1401-N51
1401-N52
1401-N53
1401-N54
1401-N55
1494G
1495-N56
1494V
1495-N59
1494G
1495-N57
1494V
1495-N60
1494G, 1494V
1495-N61
1494F, 1494G,
1494M, 1494R,
1494V Disconnect
Switches
30
60
100
200
400
600
30100 A
Protective Fuse Cover with Door
1401-N41
200 A
400600 A
All terminals of the 30 A switches are furnished with self-lifting pressure plate connectors as standard.
1-205
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-206
Bulletin 1494
Cat. No.
1494V-H12
Operating handles
1494V-H1 or 1494VH11
1494V-H3
Operating Handles
1494V-H2
1494V-H6
Applies only to
operating handle Cat.
Nos. 1494V-H1, W1,
1494V-H4
H11 and W11 (does
not apply to dual or
remote operators).
Conduit Connectors
Metallic Conduit Connectors
1 in (25.4 mm)
1-1/4 in (31.75 mm)
1-1/2 in (38.1 mm)
2-1/2 in (63.5 mm)
3 in (76.2 mm)
Non-Metallic Conduit Connectors
1-206
30 A
1232-N11
60 A
100 A
200 A
400600 A
1232-N12
1232-N13
1232-N14
1232-N15
30 A
1490-N1
30 A
30 A
60 A
100 A
200 A
200 A
400600 A
1490-N9
1490-N10
1490-N11
1490-N5
1490-N6
1490-N7
1490-N8
30 A
1490-N19
30 A
30 A
60 A
100 A
200 A
200 A
400600 A
1490-N20
1490-N21
1490-N22
1490-N23
1490-N24
1490-N25
1490-N26
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-207
Bulletin 1494
Cat. No.
1494V-L1
1494V-LL1
1494V-LL1
and 1494V-L2
1494V-L1
and 1494V-L2
1494V-L3
Cat. No. 1494V-L2
1494V-LL3
1494F-L1
1494F
1494M,
1494D
1494F-LL1
1494F-L2
1494F-LL2
1494F-L2
and 1494F-L3
1494F-LL2
and 1494F-L3
1494F-LL4
1494F,
1494M,
1494D,
1494V
1494F-N20
1494F-N21
Door hardware kit does not include rectangular connecting bars (1/4 in x 1/2 in). To be provided by customer.
Door hardware kit does not include rectangular connecting bars (1/4 in x 5/8 in). To be provided by customer.
Master door Interlock Kit does not include rectangular connecting bars (3/8 in x 3/8 in). To be provided by customer.
If the Allen-Bradley Door Hardware Kits are to be installed in a commercially available enclosure, consult the enclosure manufacturers application data for
proper kit selection.
1-207
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-208
Bulletin 1494
Specifications
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Switch Size
Rated insulation voltage Ui (UL) IEC
Ratings
UL/CSA/NEMA
HP
Continuous
Current
200 A
400 A
600 A
(600) 660V
230V/60 Hz
460V/60 Hz
575V/60 Hz
250V DC
600V AC
250V DC
7.5
15
20
5
15
30
50
10
30
60
75
20
60
125
150
40
125
250
350
50
200
400
500
50
30 A
60 A
100 A
200 A
400 A
600 A
A600, P300
1494V (30A600A), 1494G (400A600A)
AC11
Make or Break
Ratings
Ue 600V AC
600V DC
DC11
Make or Break
360 VA
360 VA
1494F (30A200A), 1494G (30A200A), 1494R (30A200A), 1494M (30A200A)
NEMA/EEMAC
138 VA
138 VA
B600, P300
Ui
IEC Ratings
ACII
,th
660V
Ux
10A
12120V
220240V
380400V
500600V
,e
6A
3A
1.5A
1.2A
Mechanical
Degree of protection
Operating
handles
Temperature
Altitude (per IEC 947-5)
Relative Humidity (per IEC 947-3)
Dielectric strength
Electrical life
Short Circuit Withstand Capability
Operating
Storage
Phenolic
Copper, tin-plated
30 A
#10 - 32 screw and self-lifting pressure plate
60 A
1/4 in - 28 screw-lug, copper alloy
100 A
5/16 in - 24 screw-lug, copper alloy
Terminals
200 A
3/8 in - 24 screw-lug, copper alloy
400 A
1/2 in - 13 screw-lug, copper alloy
600 A
1/2 in - 13 screw-lug, copper alloy
All wire rated (167 F) 75 C or higher must be sized per the local Electric Code for (167 F) 75 C wire.
30 A
#148 AWG (1.510 mm2)
#144 AWG (2.516 mm2)
60 A
#81/0 AWG (1050 mm2)
100 A
Conductor Size (mm2)
#64/0 AWG (1695 mm2)
200 A
2 of #1/0 AWG350 MCM (2 per lug) 2 of 185 mm2350 MCM
400 A, 600 A
Conductor into Lug
Lug to Terminal
30 A
20 lb-in
20 lb-in
60 A
45 lb-in
50 lb-in
Recommended Torque
100 A
150 lb-in
90 lb-in
200 A
275 lb-in
175 lb-in
400 A
325 lb-in
275 lb-in
600 A
325 lb-in
275 lb-in
Mechanisms
Zinc-Plated Steel, Bronze Chromate finish
1-208
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-209
Bulletin 1494
Specifications
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Bulletin 1494D, 1494V Circuit Breakers
Electrical Ratings
150 A
250 A
Auxiliary Contacts
Frame Size
400 A
HP
600 A
800 A
1200 A
125
250
350
200
400
500
(600) 660V
230V/60Hz
460V/60 Hz
575V/60 Hz
7.5
15
15
30
20
50
Auxiliary Contacts
30
60
75
60
125
150
1494V, 1494D
NEMA/EEMAC
IEC Ratings
ACII
B600, P300
12120V
220240V
380400V
500600V
2
Ux
,e
6A
3A
1.5A
1.2A
Mechanical Data
Mechanical Life (Typical)
10 000
Construction
Mechanisms
Zinc-plated steel
Environmental Data
Operating
Storage
Ambient Temperature
20+40 C (4+104 F)
40+65 C (40+149 F)
2000 m per IEC 337-1
90% @ 20 C, 50% @ 40 C
Class H
HRCI-H
30600 A
600V
250V
30600 A
10 kA
Electrical
Class J
HRCI-J
30600 A
600V
250V
30600 A
200 kA
Class R
HRCI-R
30600 A
600V
250V
30600 A
Class C
HRCI-C
30600 A
600V
250V
30600 A
Class CC
HRCI-MISC
30 A
600V
250V
30 A
200 kA
100 kA
200 kA
Construction
Fuse Clips
Terminals
Fuse Block Base
Ambient Temperature
Open
Enclosed
Storage
20+55 C (4+131 F)
20+40 C (4+104 F)
40+65 C (40+149 F)
2000 m
90% at 20 C and 50% at 40 C
1-209
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-210
Bulletin 1494
Dimensions
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1494V
Disconnect Switches
NEMA Size
(A)
A
6-19/64
(160)
6-19/64
(160)
6-19/64
(160)
8-5/64
(205.2)
15-23/32
(399.2)
15-23/32
(399.2)
30
60
100
200
400
600
B
Max.
7-31/32
(202)
8-15/32
(215)
9-1/8
(231.8)
15-9/64
(384.5)
18-7/32
(479.2)
17-19/32
(446.8)
C
Min.
6-3/4
(171)
6-3/4
(171)
6-3/4
(171)
7-3/4
(197)
9
(229)
9
(229)
Max.
21-5/8
(549)
21-5/8
(549)
28-5/8
(599)
21-5/8
(549)
21-5/8
(549)
21-5/8
(549)
D
2-3/4
(69.9)
2-9/16
(65.1)
3-37/64
(90.9)
6-35/64
(166.3)
8
(203.2)
12
(304.8)
E
7-9/16
(192)
7-9/16
(192)
7-9/16
(192)
8-25/32
(223)
11-27/32
(300.8)
11-27/32
(300.8)
F
3-7/8
(98.5)
3-7/8
(98.5)
3-7/8
(98.5)
4-21/32
(118)
8-51/64
(223.3)
8-51/64
(223.3)
Circuit Breakers
C
Frame
125A
140U-H, 140M-H, EF, HMCPE
150A
EHD, FD, FDB, FDC, HFD, HMCP
250A
140U-J, 140M-J, EF
250A
JD, JDB, JDC, HJD, HMCP
400 A
KD, KDB, KDC, HKD, HMCP
Min.
Max.
6
(152.4)
6-3/4
(171.5)
23
(584.2)
6
(152.4)
5-7/16
(138.1)
5
(127)
11-1/4
(285.8)
7-7/8
(200.0)
22-9/16
(573.1)
10
(254)
5-23/32
(145.2)
9-23/32
(246.8)
11-3/8
(228.9)
7-7/8
(200.0)
22-9/16
(573.1)
12
(304.8)
7-1/8
(181.0)
9-21/32
(245.3)
1-210
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-211
Bulletin 1494
Dimensions
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
C
NEMA Size (A)
30
60
100
200
Min.
5-15/16
(150.8)
5-15/16
(150.8)
7-15/16
(200.4)
10-1/2
(266.7)
10-3/4
(273.1)
13-3/16
(335)
16-3/4
(425.5)
20-13/16
(528.6)
6-3/8
(161.9)
6-3/8
(161.9)
8-1/2
(215.9)
9
(228.6)
Max.
Small
30
60
100
200
30
60
100
200
5-15/16
(150.8)
5-15/16
(150.8)
7-15/16
(200.4)
10-1/2
(266.7)
10-3/4
(273.1)
13-3/16
(335)
16-3/4
(425.5)
20-13/16
(528.6)
6-3/8
(161.9)
6-3/8
(161.9)
8-1/2
(215.9)
9
(228.6)
5-15/16
(150.8)
5-15/16
(150.8)
7-15/16
(200.4)
10-1/2
(266.7)
10-3/4
(273.1)
13-3/16
(335)
16-3/4
(425.5)
20-13/16
(528.6)
6-3/8
(161.9)
6-3/8
(161.9)
8-1/2
(215.9)
9
(228.6)
E
F
G
Without Door Hardware
2-3/16
7-1/2
3-3/4
1-3/16
(55.6)
(190.5)
(95.3)
(30.2)
2
7-1/2
3-3/4
1-3/16
(50.8)
(190.5)
(95.3)
(30.2)
5
8-1/4
3-3/4
1-3/16
(127)
(209.6)
(95.3)
(30.2)
7
11-3/8
5-9/16
1-1/4
(177.8)
(289)
(141.3)
(31.8)
and Intermediate Enclosures with Door
2-3/16
7-1/2
(55.6)
(190.5)
2
7-1/2
(50.8)
(190.5)
5
8-1/4
(127)
(209.6)
7
11-3/8
(177.8)
(289)
Large Enclosures
2-3/16
(55.6)
2
(50.8)
5
(127)
7
(177.8)
7-1/2
(190.5)
7-1/2
(190.5)
8-1/4
(209.6)
11-3/8
(289)
3-3/4
(95.3)
3-3/4
(95.3)
3-3/4
(95.3)
5-9/16
(141.3)
with Door
3-3/4
(95.3)
3-3/4
(95.3)
3-3/4
(95.3)
5-9/16
(141.3)
8-1/2
(215.9)
8-1/2
(215.9)
8-1/2
(215.9)
11-1/8
(282.6)
Hardware
1-7/16
(36.5)
1-7/16
(36.5)
1-7/16
(36.5)
1-11/16
(42.9)
15/32
(11.9)
15/32
(11.9)
15/32
(11.9)
13/16
(20.6)
7-3/16
(182.6)
7-3/16
(182.6)
7-3/16
(182.6)
9-1/2
(241.3)
2-1/8
(54)
2-1/8
(54)
2-1/8
(54)
2-9/32
(57.9)
2-1/16
(52.4)
3-1/4
(82.6)
8-9/64
(206.8)
10-13/32
(264.3)
1-3/16
8-1/2
(30.2)
(215.9)
1-3/16
8-1/2
(30.2)
(215.9)
1-3/16
8-1/2
(30.2)
(215.9)
1-1/4
11-1/8
(31.8)
(282.6)
Hardware
1-7/16
(36.5)
1-7/16
(36.5)
1-7/16
(36.5)
1-11/16
(42.9)
15/32
(11.9)
15/32
(11.9)
15/32
(11.9)
13/16
(20.6)
7-3/16
(182.6)
7-3/16
(182.6)
7-3/16
(182.6)
9-1/2
(241.3)
2-5/32
(54.8)
2-5/32
(54.8)
2-5/32
(54.8)
2-5/16
(58.7)
2-1/4
(57.2)
3-1/4
(82.6)
8-9/64
(206.8)
10-13/32
(264.3)
1-3/16
(30.2)
1-3/16
(30.2)
1-3/16
(30.2)
1-1/4
(31.8)
1-7/16
(36.5)
1-7/16
(36.5)
1-7/16
(36.5)
1-11/16
(42.9)
15/32
(11.9)
15/32
(11.9)
15/32
(11.9)
13/16
(20.6)
7-3/16
(182.6)
7-3/16
(182.6)
7-3/16
(182.6)
9-1/2
(241.3)
2-1/4
(57.2)
2-1/4
(57.2)
2-1/4
(57.2)
2-11/32
(59.5)
2-3/4
(69.9)
3-1/4
(82.6)
8-9/64
(206.8)
10-13/32
(264.3)
8-1/2
(215.9)
8-1/2
(215.9)
8-1/2
(215.9)
11-1/8
(282.6)
A
7-13/16 (198.4)
11-1/2 (292.1)
11-1/2 (292.1)
11-3/8 (288.9)
16 (406.4)
22 (558.8)
16 (406.4)
C
Min.
6-3/8 (161.9)
8-3/8 (212.7)
8-3/8 (212.7)
9-1/2 (241.3)
9-1/2 (241.3)
9-1/2 (241.3)
9-1/2 (241.3)
Max.
D
6 (152.4)
8 (203.2)
12 (304.8)
8 (203.2)
10 (254)
10 (254)
12 (304.8)
E
5-5/8 (142.9)
5-13/16 (147.6)
6-7/8 (174.6)
12 (304.8)
12-5/16 (312.7)
12-5/16 (312.7)
12-5/16 (312.7)
F
6-7/16 (163.5)
9-7/16 (239.7)
9-7/16 (239.7)
10-17/32 (267.5)
15-3/32 (183.4)
21-3/32 (535.8)
25-3/32 (183.4)
1-211
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-212
Bulletin 1494
Dimensions
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Size
30 A
60 A
30 A
60 A
100 A
30 A
60 A
30 A
60 A
30 A
60 A
100 A
100 A
100 A
200 A
100 A
200 A
200 A
400
600
400
600
A
A
A
A
Fuse
Style
Number
of Poles
Bulletin
No.
A
Height
B
Width
Approx.
Shipping
Weight in
lbs (kg)
2 or 3
1494G
13 5/16
(338)
10 1/2
(267)
8 1/4
(210)
14 11/16
(373)
5 1/4
(133)
5 9/16
(141)
15 21/32
(398)
11/32
(9)
20
(9.07)
2 or 3
1494G
20
(509)
10 1/2
(267)
10 3/16
(259)
21 7/16
(545)
5 1/4
(133)
5 9/16
(141)
22 13/32
(569)
11/32
(9)
30
(13.6)
1494G
27 1/2
(698)
10 1/2
(267)
8 1/4
(210)
28 7/8
(733)
5 1/4
(133)
5 9/16
(141)
29 7/8
(759)
13/16
(21)
60
(27.21)
30
(762)
20 1/2
(521)
10 3/16
(259)
31 3/8
(797)
15 1/4
(387)
15 1/4
(387)
5 9/16
(141)
32 3/8
(822)
13/16
(21)
90
(40.82)
31 1/2
(800)
10 1/2
(267)
10 3/32
(257)
32 7/8
(835)
5 1/4
(133)
5 9/16
(141)
33 27/32
(860)
11/32
(9)
70
(31.73)
50
(1270)
22
(559)
11 1/2
(292)
51 3/8
(1305)
15 1/4
(387)
15 1/4
(387)
5 9/16
(141)
52 11/32
(1330)
11/32
(9)
200
(90.7)
B
A
C
D
C
D
A
B
A
B
A
B
A
B
D
A
B
B
C
A
A
B
B
C
D
A
B
A
A
B
B
2 or 3
1494GY
2 or 3
1494GX
1494G
2 or 3
1494GY
2 or 3
6
2 or 3
1494G
2 or 3
1494GX
2 or 3
6
1494G
2 or 3
1494GY
2 or 3
1494G
50
(1270)
22
(559)
11 1/2
(292)
51 3/8
(1305)
15 1/4
(387)
15 1/4
(387)
7 5/8
(194)
52 11/32
(1330)
11/32
(9)
200
(90.7)
2 or 3
1494G
56
(1422)
30 1/2
(775)
13 51/64
(350)
57 5/8
(1464)
20
(508)
25 1/4
(641)
7 5/8
(194)
62 5/8
(1590)
1
(25.4)
300
(136.05)
1-212
Bulletin_1494.qxd
05/02/2004
20:21
Page 1-213
Bulletin 1494
Dimensions
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Size
30 A
60 A
30 A
60 A
30 A
60 A
30 A
60 A
100 A
100 A
100 A
200 A
200 A
400 A
600 A
Fuse
Style
Number
of Poles
2 or 3
B
C
D
B
C
D
A
B
A
B
A
B
A
B
A
B
C
D
A
B
A
B
A
B
C
D
A
B
A
B
A
B
2 or 3
Bulletin
No.
A
Height
B
Width
1494G
13 5/16
(338)
10 1/2
(267)
8 9/16
(217)
14 11/16
(373)
27 1/2
(698)
10 1/2
(267)
8 1/4
(210)
30
(762)
20 1/2
(521)
50
(1270)
56
(1422)
Approx.
Shipping
Weight in
lbs (kg)
5 1/4
(133)
5 9/16
(141)
15 21/32
(398)
13/16
(21)
20
(9.07)
28 7/8
(733)
7
(178)
5 9/16
(141)
29 3/4
(756)
13/16
(21)
60
(27.21)
9 7/8
(251)
31 3/8
(797)
17
(432)
17
(432)
5 9/16
(141)
32 1/4
(819)
13/16
(21)
90
(40.82)
22
(559)
11 3/16
(284)
51 3/8
(1305)
18 1/2
(470)
18 1/2
(470)
5 9/16
(141)
52 1/4
(1327)
13/16
(21)
200
(90.7)
30 1/2
(775)
13 51/64
(350)
57 5/8
(1464)
20
(508)
25 1/4
(641)
7 5/8
(194)
58 5/8
(1489)
1
(25.4)
300
(136.05)
6
2 or 3
1494G
2 or 3
1494GY
2 or 3
1494GX
2 or 3
1494G
6
2 or 3
1494GY
2 or 3
1494GX
2 or 3
1494G
6
2 or 3
1494GY
2 or 3
1494G
1-213
Bulletin_1494.qxd
05/02/2004
20:22
Page 1-214
Bulletin 1494
Dimensions
NEMA Disconnect Switches and Circuit Breaker Operating Mechanisms, Continued
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Size
30 A
60 A
30 A
60 A
100 A
Fuse Style
A
B
A
B
A
B
A
B
A
B
Number of
Poles
Bulletin
No.
A
Height
B
Width
C
Depth
2 or 3
1494G
24
(610)
10
(254)
6 7/8
(175)
4 7/8
(124)
28
(12.7)
24
(610)
21
(533)
9 1/4
(235)
4 7/8
(124)
60
(27.2)
1494GX
2 or 3
1494G
1-214
Approx.
Shipping
Weight in
lbs (kg)
D
Handle
Depth