0% found this document useful (0 votes)
84 views0 pages

40-120KVA Green Power Transformerless

This document summarizes the features of the Green Power 2.0 UPS system from 10-120 kW. It offers the highest efficiency in the market using a VFI double conversion mode. It provides full rated power up to 35°C without downgrading. It saves significant costs through 96% maximum efficiency, reducing energy losses by 50% compared to legacy UPS. The UPS is suitable for data centers, telecom, services and IT networks due to its high availability, ultra-high energy efficiency and maximum available power.

Uploaded by

tceterex
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views0 pages

40-120KVA Green Power Transformerless

This document summarizes the features of the Green Power 2.0 UPS system from 10-120 kW. It offers the highest efficiency in the market using a VFI double conversion mode. It provides full rated power up to 35°C without downgrading. It saves significant costs through 96% maximum efficiency, reducing energy losses by 50% compared to legacy UPS. The UPS is suitable for data centers, telecom, services and IT networks due to its high availability, ultra-high energy efficiency and maximum available power.

Uploaded by

tceterex
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 0

40 General Catalogue 2012

T
h
r
e
e
-
p
h
a
s
e

U
P
S
Energy Saving: high efficiency
without compromise
Offers the highest efficiency in the market
using VFI Double Conversion Mode, the
only UPS working-mode that assures total
load protection against all mains quality
problems.
Ultra high efficiency output independently
tested and verified by an international
certification organization in a wide range of
load and voltage operating conditions, to
have the value in the real site conditions.
Ultra high efficiency in VFI mode is
provided by an innovative topology (3-Level
technology) that has been developed for all
the Green Power UPS ranges.
Full-rated power: kW=kVA
No power downgrading when supplying the
latest generation of servers in typical data
centre conditions.
Full power UPS design up to 35 C, with
25% more power compared to UPS with
PF=0.8 and 11% more power compared to
UPS with PF=0.9.
Suitable also for leading power factor loads
down to 0.9 without derating.
Significant cost-saving (TCO)
Maximum energy saving thanks to 96%
output efficiency: 50% saving on energy
losses compared to legacy UPS gives
significant savings in energy bill.
UPS self-paying with energy saving.
Energy Saver mode for global efficiency
improvement on parallel systems.
kW=kVA means maximum power available
with the same size of UPS, and therefore
less /kW.
With its clean rectifier, Green Power 2.0
UPS significantly optimize the upstream
infrastructure without over rating the supply
system (i.e. generator sets, switches,
cables, protection devices).
High efficiency minimizes the amount of
battery for an equivalent back-up time.
Battery configuration can be optimized,
thanks to a very wide DC range.
Extended battery life and performance:
- long life battery,
- very wide input voltage (-40% / +20%) and
frequency (45 to 65 Hz) without battery
use,
- EBS (Expert Battery System) charging
management improves battery service life.
Green Power 2.0
MASTERYS GP from 10 to 120 kVA/kW
high availability, ultra high energy efficiency
and maximum power available
The solution for
> Data centres
> Telecommunications
> Service sector
> IT-Networks / Infrastructures
Complementary pages
> External battery cabinets,
page 82
> Communication and
connectivity, page 102
> Technology, page 110
G
A
M
M
E

2
0
2

C
Certifications
The Green Power 2.0 series
is certified by TV SD with
regard to product safety
(EN62040-1).
G
A
M
M
E

1
2
5

B
Energy saving + Full rated power = TCO
Advantages
Better performance
than the EU Code of Conduct
on efciency of AC UPS
41 General Catalogue 2012
Green Power 2.0
MASTERYS GP from 10 to 120 kVA/kW
Three-phase UPS
Technical data
MASTERYS GP
Sn [kVA] 10 15 20 30 40 60 80 100 120
Pn [kW] (0 C 35 C) 10 15 20 30 40 60 80 100 120
Input / output 3/1 - - - - - -
Input / output 3/3
Parallel configuration up to 6 units
INPUT
Rated voltage 400 V 3ph+N
Voltage tolerance 240 V to 480 V
(1)
Rated frequency 50/60Hz 10%
Power factor / THDI >0.99 / <2.5%
OUTPUT
Rated voltage
1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (can be configured 380/415 V)
Voltage tolerance static load 1 % dynamic load in accordance with VFI-SS-111
Rated frequency 50/60 Hz
Frequency tolerance 2% (configurable from 1% to 8%)
Total output voltage distortion -
linear load
< 1%
Total output voltage distortion -
non-linear load
< 3%
Overload 125% for 10 minutes, 150% for 1 minute
(1)
Crest factor 3:1
BYPASS
Rated voltage rated output voltage
Voltage tolerance 15% (configurable with from 10% to 20%)
Rated frequency 50/60 Hz
Frequency tolerance 2%
EFFICIENCY (TV SD verified)
Online mode @ 50 % of load up to 96%
Online mode @ 75 % of load up to 96%
Online mode @ 100 % of load up to 96%
Eco Mode up to 98%
ENVIRONMENT
Operating ambient temperature from 0C up to +35C (from 15C to 25C for maximum battery life)
Relative humidity 0% - 95% without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m (ISO 3746) < 52 dB < 55 dB < 60 dBA < 65 dBA
UPS CABINET
Dimensions W x D x H (mm) 444 x 795 x 800 444 x 795 x 1000
444 x 795
x 1400
600 x 800 x1400 700 x 800 x 1930
Weight 190 kg 195 kg 315 kg 320 kg 180 kg 200 kg 380 kg 460 kg
Degree of protection IP20
Colours RAL 7012
STANDARDS
Safety EN 62040-1 (TV SD certified), EN 60950-1
EMC EN 62040-2
Performance EN 62040-3 (VFI-SS-111)
Product declaration CE
(1) conditions apply
Advanced interface
Up to 30 languages embedded.
Colour graphic display.
Commissioning wizard.
Standard electrical features
Dual input mains.
Internal maintanance bypass.
Backfeed protection: detection circuit.
EBS (Expert Battery System) for battery
management.
External temperature sensor.
Electrical options
External maintanance bypass.
External battery cabinet.
Additional battery chargers.
Galvanic isolation transformer.
Parallel kit.
ACS synchronization system.
Standard communication
features
MODBUS TCP.
MODBUS/JBUS RTU.
Embedded LAN interface (web pages,
email).
2 slots for communication options.
Communication options
Remote mimic panel.
Dry-contact interface.
PROFIBUS.
NET VISION: professional WEB/SNMP
interface for UPS monitoring and shutdown
management of several operating systems.
Remote maintenance
T.SERVICE: maintenance software
for continuous 24/7 monitoring of the
SOCOMEC UPS.