Wirand FF3HS Eng

WIRAND(r) cold drawn steel wire fiber FF3HS for structural concrete reinforcement. Double end hooks ensure perfect anchorage in concrete.

Uploaded by

tetum22
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
155 views1 page

Wirand FF3HS Eng

WIRAND(r) cold drawn steel wire fiber FF3HS for structural concrete reinforcement. Double end hooks ensure perfect anchorage in concrete.

Uploaded by

tetum22
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TECHNICAL DATA SHEET Rev: 02, Issue Date 04.08.

2013

WIRAND FIBER FF3HS


Product Description
WIRAND cold drawn steel wire ber FF3HS for structural concrete reinforcement.

Nominal Dimensions

Diameter (D): 0.75 mm (0.0295 in.) Length (L): 50 mm (1.9685 in.) Aspect ratio (L/D): 50/0.75 = 67 Quantity of bers = 5700 units/kg (2585 units/lb)
Figure 1

Mechanical Properties
Rm (Tensile strength of the wire): > 1500 Mpa (217000 psi) Dl (ultimate strain) < 4%

Shape
The double end hooks of WIRAND FF3HS bers ensure perfect anchorage in concrete.

Reference Standards

ASTM A820: 2006 - Standard Specication for Steel Fibers for FiberReinforced Concrete; EN 14889-1: 2006 - Fibers for concrete Part 1: Steel bers Denition, specications and conformity; UNI EN 14845-1:2007 - Test method for bers concrete Part I: Reference concrete UNI EN 14845-2:2007 - Test method for bers concrete Part II: Effect on concrete; EN 14651-2005 - Test method for metallic ber concrete - Measuring the exural tensile strength (limit of proportionality (LOP), residual); UNI 11037: 2003 Fiber dacciaio da impiegare nel confezionamento di conglomerato cementizio rinforzato; UNI 11039: 2003 Steel ber-reinforced concretePart 1: denitions, classications, specics and conformity; Part II: Test method used to determine the early crack strength and ductility indexes; CNR DT 204/2006 Istruzioni per la progettazione, lEsecuzione ed il Controllo di Strutture di Calcestruzzo Fibrorinforzato; RILEM, 2001 Test and design methods for steel ber reinforced: uniaxial tension test for steel ber reinforced concrete, RILEM TC 162-TDF Recommendations, Materials and Structures. MODEL CODE 2010: 5.6 Fibers/ber reinforced concrete; 7.7 Verication of safety and serviceability of FRM structures.

Figure 2

Figure 4

Packaging
WIRAND FF3HS bers are delivered in large bags of 600 kg (1323 lb), or in carton boxes of 20 kg (44 lb).

Optional Dosage Equipment

Optional Dosage Equipment

Figure 5

www.maccaferri-usa.com

Headquarters: 10303 Governor Lane Boulevard Williamsport, MD 21795-3116 Tel: 800-638-7744 Fax: 301-223-4590 [email protected]

Area Ofces: AZ, Phoenix CA, Sacramento FL, Coral Gables NJ, Iselin

MD, Williamsport MO, St. Louis NM, Albuquerque PR, Caguas

TX, Lewisville WA, Seattle

2013 Maccaferri, Inc. Printed in USA

You might also like