0% found this document useful (0 votes)
395 views36 pages

Efs Brochure 11-2010

The document summarizes the EFS2000 electric fail-safe actuator from Biffi. It integrates advanced ICON2000 technology with a spring-return mechanism for safety applications on valves. Key features include integrated diagnostics, partial stroke testing, SIL certification, and wireless connectivity. It uses a spring-return system to move the valve to a fail-safe position in emergencies or power failures through an electromagnetic clutch and hydraulic controls.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
395 views36 pages

Efs Brochure 11-2010

The document summarizes the EFS2000 electric fail-safe actuator from Biffi. It integrates advanced ICON2000 technology with a spring-return mechanism for safety applications on valves. Key features include integrated diagnostics, partial stroke testing, SIL certification, and wireless connectivity. It uses a spring-return system to move the valve to a fail-safe position in emergencies or power failures through an electromagnetic clutch and hydraulic controls.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

2000

t uc re od hu Pr roc B

EFS2000: the hi-tech electric fail-safe actuator


A simple electric actuator designed and engineered to operate safety v a l v e s w i t h I C O N 2 0 0 0 a d v a n c e d a n d r e l i a b l e s o l u t i o n s

Features
More than half a century ago Biffi started its business in valve actuation. Its world-wide leadership has been built through continuous innovation and the ability to face the new challenges that a fast changing environment comes up with. It was in 1992 that Biffi started its intelligent actuator campaign. Since then Biffi Intelligent actuators have been welcomed by all major companies around the world, in many different applications: platforms, deep tropical forest, Siberian chill and harsh desert environment. With ICON2000, we made a further step forward towards ease of use and maintenance. Release 2004 of ICON2000 introduces a new philosophy in the construction of electric actuators electronic cards: all major optional functions are integrated in the base card, which allows easy plug-in of future upgrades. EFS2000 is the latest step in the acknowledgement of Biffi product quality and reliability. EFS2000 integrates in one single actuator all the advanced technological solutions of the ICON2000v4 with a strong and reliable spring-return mechanism for safe applications. The EFS2000 is an Electric Quarter Turn Spring Return Actuator which has the purpose to close or open a valve in emergency conditions, when an ESD alarm signal occurs or when motor power supply fails. Actuator operation, setting and diagnostics are available via the integral user-friendly pushbutton panel BluetoothTM, radiofrequency wireless connector based on a qualified BluetoothTM class 1 module(*) available as standard Watertight and explosion-proof PDAs are available from Biffi Italia for actuator operation, download of diagnostic info, non-intrusive upgrading of firmware and for maintenance purposes through BluetoothTM Enhanced hardware and software performances to offer: - advanced maintenance data including reports on the last opening and closing position/torque curves with relative parameters and with direct comparisons with reference curves; - detailed and updated information on actuator internal parameters with precise and clear alarm reports, with both General and Recent (partial) log; - Data logger function for collecting different types of data for maintenance or diagnostic programs, available both in: RECORDER mode for measurement and memorization of main actuator internal parameters with configurable SAMPLING TIME and START DATE and TIME EVENT mode with memorization of OPEN or CLOSE commands, including indication of source, date and time with configurable START DATE and TIME T-RECORDER mode for measurement and memorization of torque and temperature with configurable SAMPLING TIME, START DATE and TIME. STOP of recording in case of torque alarm.
(*)
!@#$ flow control

US and Italy patented Bluetooth is a trademark of Bluetooth SIG, Inc., USA

Customized displays: - Numeric: 31/2 digits, for the indication of position or torque - Graphic: 32x122 dots, for a complete diagnostic user-friendly communication with the operator - Backlights - Heater - 8 selectable languages as standard A single enhanced-type terminal board Advanced open bus communication protocols: - Lonworks - Profibus DPV0, DPV1 and Redundant DPV1 - Foundation Fieldbus - Modbus - Hart

Diagnostics
Internal circuits continuously monitor the status of the system and elaborate all the information coming from the sensors: diagnostic messages are displayed in one of the available languages, so that there is no need to decipher complicated codes. The set of messages is complete both with alarms and warnings.

Partial Stroke Test (PST)


The PST is proposed as an essential part of the diagnostics. Through a specific procedure a partial stroke test function can be carried out to check the functionality of the essential parts achieve the EFS safety function while the valve/actuator is in line and in service.

SIL Certified
Suitable for use in SIL 3 applications following IEC 61508 / IEC 61511 - TUV Certified.
..

!@#$ flow control

The EFS2000 actuator consists of six main parts:


1. a spring return mechanism, which moves the valve in the foreseen fail-safe condition when requested by an ESD signal or by a motor power failure. 2. a multiturn electric actuator which operates, through an epicyclic gear reduction (3) the valve during normal working conditions and in the mean time compress the spring when the operation is in opposite direction to the fail safe direction. 3. an epicyclic gear reduction, which increment the torque of the multi turn actuator and transform the stroke into a quarter turn value. 4. an electro-magnetic clutch which hold in position the female wheel of epicyclic gear (3) during the normal operation and release it in case of fail-safe function. 5. an hydraulic control group which is necessary to adjust the fail-safe speed and to manually operate the actuator by means of a hand-pump in case of power failure. 6. a local control and configuration panel which is utilised to configure the functional parameters and to operate locally (OPEN/CLOSE/OFF-EMERGENCY/RESET) the actuator when electric power is present.

Working Principle
The spring return system is kept in fail safe position by helical springs. During the normal operation the multi-turn turn electric actuator transmits the movement to the valve through the epicyclic gearing reduction and to the spring return mechanism through the rack. Spring return mechanism is based on rack-pinion mechanism; the rack is connected in one side to the spring and in the other side to the hydraulic cylinder; pinion of rack-pinion mechanism is connected to the valve stem. Input shaft of the epicyclic gearing reduction is connected the multi-turn actuator output shaft; output shaft of the epicyclic gearing reduction is connected to the pinion of rack-pinion mechanism. The female wheel of the epicyclic reduction is reversible: during normal operation it is kept on position by means of a electromagnetic clutch which hold the worm shaft connected to the epicyclic gearing. The coil of the electromagnetic clutch is normally fed by a direct current from separated external power source, or derived from motor power voltage, through a supply module. When the ESD condition occurs, the supply to the electromagnetic clutch is cut causing the disconnection of system which hold the worm shaft: in this conditions the epicyclic gearing become reversible causing the movement of the actuator on the fail condition by the effect of the spring. To avoid dangerous shock to the valve during the ESD action, an hydraulic damper is mounted on the spring system, whit an adjustable flow control orifice to be set to obtain the specified ESD times. Position of the valve is continuously monitored both in electric mode, both in fail-safe condition, by means of a position sensor directly connected the EFS output drive. After a Fail-Safe action, a local RESET is required, through the local control panel. Emergency Closing Operation In case of electric supply failure the electromagnetical lach opens and the actuator moves the valve in closing position by spring
!@#$ flow control

Fail safe time regulation The closing time is adjustable by flow regulator 526 Local manual operation to open In case of loss of electric supply , switch valve 998 to manual mode and actuate hand pump 540 to open the actuator Local manual operation to close With valve 998 in manual position press the lever of hydraulic pushbutton 414, the actuator moves in closing by spring 1 30 352 356 379 395 414 526 527 528 540 621 966 998 999 398 Single acting spring return hydraulic actuator Hydraulic accumulator (piston type/spring return) Needle valve Hydraulic filter Check valve Safety relief valve 2/2 N.C. hand-operated spring-return valve Bidirectional flow regulator Nozzle Unidirectional flow regulator (adjustable setting) Handpump LP/HP pressure gauges Terminals enclosure 2/2 N.C. hand-operated valve (auto/manual) Electromagnetical latch PST SOV (optional)

Selector 998 is drawn in AUTO position

Control Group Functions


EFS2000 are equipped with an Hydraulic Control Group with two base functions: Adjustment of fail safe time Manual override function to operate the EFS when electrical power is not available. Adjustment of fail safe time is done trough the flow control valve (528). Manual override through the hand pump (540). Before to perform the local manual operation by hand-pump it is necessary to guarantee that the electromagnetic clutch is open: press the pushbutton OFF (Red mushroom) on the local control panel to be sure that clutch is really open. After the above operation, using a local two-positions (AUTO/MANUAL) hydraulic selector (998), select the local operation mode and successively through the hand pump manual operation can be carried out. At the end of manual operation, if the actuator is required to remain in the position opposite to the spring, it is necessary to leave the hydraulic selector in MANUAL position. To restore the electric mode function the hydraulic selector must be moved to AUTO position and, as soon the electrical power is available, the red mushroom pushbutton must be pressed to RESET the actuator. Select then LOCAL or REMOTE position, on the local control panel, according to the wanted type of operation.

AUTO
Legenda
1 - Single acting spring return hydraulic actuator 30 - Hydraulic accumulator 39 - Selector position microswitch 352 - Needle valve 356 - Hydraulic filter 379 - Check valve 395 - Safety relief valve 414 - Hydraulic pushbutton 526 - Adjustable flow regulator 527 - Flow regulator 540 - Handpump

MANUAL
621 - Pressure gauce 966 - Terminals enclosure 998 - Auto/manual selector 999 - Electromagnetic latch
!@#$ flow control

...in cost reduction and user-friendliness


The reduced number of mechanical parts ensures higher reliability and lower maintenance costs. The aluminium alloy highly resistant housing and covers, together with a lower number of joints, have increased EFS capacity to stand up to the most aggressive environments. A double-sealed enclosure assures protection from dust and humidity. The choice of internal components has increased the overall system efficiency (the motor is directly engaged to the gears) lowering the operational costs. Reduction of training costs is also one of the goals we have achieved through the user-friendliness of the system. No more codes to decipher: the EFS menu is clear and easy, and comes with all the following languages: Italian, English, Spanish, Portuguese, French,Turkish, Russian and Norwegian.

Torque sensor
The direct measure of the motor speed reports torque with high precision and a resolution of 1% of the nominal torque. Torque detection is based on motor torque vs. speed characteristics, voltage and temperature compensated. The torque vs. speed curve is memorised for each type of motors and in case of motor replacement simply a new configuration from the actuator local control panel is requested.

Position sensor
Low power consumption, long-life, absolute position sensor controlled by a dedicated microprocessor. Rotations in both senses are recognised and counted. If manually operated during power failure, the position is updated, stored and displayed locally.

Electronic card: the latest technology


The card is controlled by an high-performance microchip, with a slash memory. This allows high flexibility and the possibility to be re-programmed if necessary. The internal wiring is considerably reduced. The modular design of the electronic cards allows high flexibility for a great variety of combinations. All the electronic cards are treated with a tropicalisation protection in order to increase the performances even in the most severe enviromental conditions.

!@#$ flow control

!@#$ flow control

A dedicated software for PC and PDA is available for EFS 2000. With the new software, total control of EFS 2000 is always available in your hands and in your office. With a smart user-friendly graphic interface, all the actuator information, set-up, configuration data, diagnostic messages and data logger info are available for visualisation, analysis and reconfiguration from your PDA or PC.

PDA Manager
The PDA Manager will transform your common PDA or dedicated industrial PDA into a strong tool for the complete control, set-up and diagnostics of the EFS 2000 actuators installed in your plant. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. EFS 2000 supports BluetoothTM non-intrusive communication with the possibility to communicate with the actuator within a distance of several meters from any angle. In addition, it is possible to connect to all the actuators within operation distance with one single PDA.

!@#$ flow control

All the data exchanged with the actuator on-field can be shared with your PC in the office through the PC Manager Software. Connect the PDA to the PC with the ActiveSync program and download all the data. Standard PDA minimum basic requirements: Operating systems: Windows MobileTM 2003 for Pocket PC; BluetoothTM interface module; Processor: 266 MHz processor; Memory: 32 MB SDRAM minimum; 3.5" TFT display with 16k colour depth. Ex-hazardous area industrial PDA technical characteristics: - High performance industrial PDA based on Windows MobileTM, with compact external dimensions, an integrated WLAN, USB and BluetoothTM port. - Meets different industry requirements operating both inside and outside of Ex-hazardous areas.

Basic features: Ergonomic design to facilitate operations without fatigue during continuous use; High resolution colour display, readable even in the most unfavourable light conditions; Protection from static electricicty, water and dust; Shockproof housing (non-corroding); Standard keyboard with navigation field and programmable keys; 3.5" TFT display with 16k colour depth.

Technical data sheet: Operating systems: Windows MobileTM 2003 Premium-Software for Pocket PC; Processor: 400 MHz processor based on Intel technology; Power supply: Rechargeable battery; Standard delivery: Unit, Charger, Operating instructions, safety instruction, software CD; Ex-Data: Ex-hazardous application intrinsically safe type and suitable for different gas and dust atmospheres, ATEX or other certification.

!@#$ flow control

PC Manager
PC Manager transforms your PC into a strong tool for the control, set-up and diagnostics of EFS 2000 actuators. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. EFS 2000 supports BluetoothTM non-intrusive communication or serial communication (intrusive).

The same interfaces available with PDA MANAGER with an improved graphic release (considering the larger screens available on PCs) are easily syncronisable with the PDA: - Actuator control:

!@#$ flow control

10

- Actuator maintenance and diagnostic informations:

- Actuator set-up:

- Actuator data logger:

PC Manager software supports BluetoothTM, or serial communication (Windows 2000 and XP operating systems).

!@#$ flow control

11

Standard ICON2000 multiturn electric actuator

Spring return mechanism


!@#$ flow control

12

Local control and configuration panel

Hydraulic control group for manual operation

Electromagnetic clutch

Epicyclic gear reduction with rack and pinion transmission

!@#$ flow control

13

The base version is an intelligent actuator with hardwired (i.e. point-to-point) connection.

High profile standards: all major features are included in the base version.
Automatic phase correction
The valve will be protected as the system automatically recognises and corrects phases preventing any unforeseen error in the rotation direction.

Phase failure correction


In case of loss of one phase, this features prevents the motor from overheating. The minimum time to set the alarm on is 100 ms, in order to prevent the system from being influenced by casual oscillations. In case of loss of one phase during motor running, the actuator will reach the end-of-travel position before setting the alarm condition and de-energising the actuator.

Motor thermostat
If during operation the temperature of the motor overrides the security limits, a thermostat will set the alarm condition and the command signal will be inhibited.

Jammed valve protection


If, after a command (close/open), the valve position does not change within a pre-set time, an alarm condition is set and the command signal will be inhibited. The pre-set time can be any time within an interval of 2 to 100 seconds.

Anti-hammer protection
This feature will protect both the motor and the valve. If a torque limit is reached it will prevent the valve from moving in the same direction which caused the torque limit.

Instantaneous reversal protection


When the actuator is operating in one direction and an immediate command for a reverse direction is set, unpredicted current surges arise with possible damages to the motor. To prevent such problems, a delay between the opposite commands can be programmed from 500 ms to 5 seconds.

Warnings
Warning signals become active when the operating conditions are close to a critical alarm level. Warning is displayed but operation is not interrupted.

Remote controls
Three different configurations are available: - 4 wires (OP, CL, Stop, C/latched) - 3 wires (OP, CL, C/push-to-run or latched with instant reverse) - 2 wires (NO contact to open or reverse)

Control voltage
- 24Vdc, internal supply - 20 to 125 Vdc, external supply - 20 to 120 Vac, external supply

!@#$ flow control

14

!@#$ flow control

15

Emergency Shutdown (ESD)


When an ESD signal is received, the actuator performs the ESD programmed action, moving on the fail position under the action of the spring. The ESD action is performed by default when the ESD signal is sent. Other conditions for ESD can be configured through the local interface: - ESD in case of loss of main power; - ESD in case of Local Selector selected in OFF position - ESD by an emergency local pushbutton (mushroom type).

Local RESET
After an ESD action, normal operation can be restored after a Local RESET through the local pushbutton, or rather be automatically restored, depending on configuration.

Analogic position retransmission


Through 4-20mA with galvanic insulation

Remote output contacts


7 voltage-free latching contacts and 1 change-over, voltage-free contact of relays are available for remote indication. They can all be configured as Normally Open or Normally Closed for one of the following conditions: Fully open Fully closed Intermediate position Position XX % Position XX % Actuator opening Actuator closing Motor running Blinker Local selected Remote selected Local stop active PST active Manual operation Motor over temperature Torque alarm Torque alarm in opening Torque alarm in closing Jammed valve alarm Jammed valve in opening Jammed valve in closing Mid-travel alarm Warning Low battery EFS in manual mode PST failed EFS mid-travel alarm MAINS (only for AS8)

Interlock controls
Two interlock inputs are available to inhibit actuator movement in open or close direction

!@#$ flow control

16

Monitor relay
When the actuator is not available for remote control, an alarm condition is set through a Monitor Relay with a change-over type, voltage free contact. The Monitor Relay is normally energized and will be de-energized under one of the following conditions: - loss of main power - speed sensor failure - loss of one phase - HW error - internal temperature alarm - mid-travel alarm - electrical contactors failure - configuration error - position sensor failure - EFS mid-travel alarm - EFS in manual mode

The following other conditions can be individually configured to switch over the Monitor Relay: - motor over temperature - Manual operation selected - over torque - ESD action - jammed valve - Local STOP pushbutton pressed - LOCAL or OFF selected - Low battery

Contactor failure
As one of the vital parts of the actuators, contactors are continuously monitored. If a malfunction is detected an alarm is set and the command is inhibited.

Maximum torque alarm


During torque operation, if the current torque exceeds the relevant set value, the actuator command is inhibited and an alarm condition is set.

Opto-coupled remote controls


Actuator may be remotely controlled by 4, 3 or 2 wires, depending on the connection on the terminal board. Several options are available: latched, momentary, etc...

Torque alarm by-pass


During opening command, starting from open/closed position it is possible to set an interval from 0% to 20% of the total stroke where torque alarm is ignored. This will allow the actuator to win the Break-to-open torque.

High/Low electronic temperature


Through a semiconductor-based temperature sensor, the temperature in the electronic card is detected and an alarm condition is set on reaching the lowest/highest limits.

!@#$ flow control

17

Local operator interface


The local interface is designed for easy operation and to supply a complete and clear set of information. It is composed of - a padlockable three-position selector for LOCAL/OFF/REMOTE operation selection - two pushbuttons for local OPEN/CLOSE controls and menu navigation - one pushbutton for local stop - 2 customised displays, with backlight and heater: numeric 31/2 digit display for torque and position indication graphic display supporting various character sets 3 bi-coloured LED (green/red) to indicate fully open/closed/intermediate position 1 bicoloured LED (red/yellow) to indicate alarm/warning state. 1 blue LED to indicate Bluetooth connection active. Class 2 Bluetooth module available for wireless connection to PDA or PC. All buttons are recessed for protection from accidents or misuse. The local pushbuttons OPEN/CLOSE can be configured with 3 options: latched, latched + instant reverse, push-to-run. Through the local interface the field operator can enter a basic configuration menu which allows to set the following parameters: Base parameters - End of travel position in opening/closing - Opening/closing torque values - Position/torque display - Opening/closing by torque/position - Output contacts - PST function - Remote/Local control feature - ESD feature The configuration menu is password-protected. Extended parameters - Timer parameters - Position servo-amplifier parameters - Fieldbus interface parameters - Data logger - Maintenance date - Diagnostic info - .

Added extra features


Predictive maintenance
Some of the most vital parts of the actuator are monitored: - contactor cycles count - torque trend - alarms data log

Timer Function Module (TMR)


It allows for partial or complete timer controlled valve stroke.Through the local/remote interface the following can be set: - if it has to be active during opening or closing operation - ON time, from 2 to 200 sec max, with resolution of 1 sec. - OFF time, from 1 to 200 sec max, with resolution of 1 sec. - percentage of position when timer starts in opening - percentage of position when timer starts in closing

Electronic card identification message


Base, terminal board EFS card and 4-20mA card are clearly identified with a 64 character message for fast track including: - Biffi assembly code - Assembly serial number - Manufacturing date - Software and Hardware versions - Description

!@#$ flow control

18

Data log
ICON2000 is complete with an exhaustive data log system which will allow for storage of main events occurring during actuator operation. The recorded data are: Alarms: Last 64 alarms and date Last 64 warnings and date Torque curves: The EFS actuator keeps track of the most recently recorded 100 curves in opening and 100 curves in closing, storing data relevant to: date, time, temperatures, main voltage, travel time, torque sample (measured each 1% of position change). Operations: Opening time of the last stroke Closing time of last stroke Total contactor operations Motor run time Time out without electrical power Utilisation rate Recent contactor operations Recent motor run time Recent time without electrical power Recent utilisation rate Maintenance dates: Last maintenance date Next maintenance date Date of the last "clear recent data log" Start-up date PST data: Last PST report Next scheduled PST date PST initial signature (sec/pos) Last 100 PST profiles (sec/pos) EFS data: EFS status Clutch coil status Manual/Auto selector status EFS card temperature (C) Mushroom pushbutton status EFS heater status Log-in recorder: The last 8 log-in data via BluetoohTM, and PDA/PC are recorded

Motor rating Motor duty Motor poles Motor type Motor current Test date Wiring diagram Enclosure Certificate Lubricant HW version SW version Torque set-up in opening Torque set-up in closing

Valve data
To identify the valve and its function in the process, the valve manufacturer/end user can enter the following data: Valve tag name Valve serial number Manufacturer Break opening torque Max stem thrust Flange type 28 characters are available for such information.

Customisable torque profiles


In some applications you need to set different torque profiles for operating the valve. For this reason we have introduced a 3-point torque profile.

Local ESD function


Local mushroom pushbutton

Emergency and PST curves


The EFS actuator keeps tracks of the most recently recorded 16 emergency curves and 16 PST curves and relevant signature (EFS and PST)

Name plate
The basic information about the actuator are electronically stored in a non-volatile memory: Serial number Actuator size Nominal torque Actuator speed Power supply
!@#$ flow control

19

The following is a description of our EFS2000 standard features/options and working conditions. For whatever you may require which is not listed below, please contact Biffi Sales offices.

Voltage ratings
The actuator can accept the following voltage supplies: Three phase: 50 Hz 230, 240, 380, 400, 415, 440, 460, 480, 500, 690 V Single phase 110, 115, 220, 240 V at 50, 60 Hz ESD signal voltage: from 24 to 230 Vac/Vdc ESD signal power: 40W in rush/24W maintained 60 Hz 208, 280, 380, 460, 480, 575 V

Tolerance on fluctuations
Voltage: 10% continuous +10% -15% intermittent Frequency: 2%

Working temperature
The standard range is -30C to +70C Extended ranges -40C to +70C Special temperature range on request.

Storage temperature
From -55C to +85C

Environmental protections
Only waterproof IP 68 according to EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 Standard explosionproof degree Ex-d IIB T4 according to IEC / EN 60079 (-40C/+70C) IP 68 according to EN60529 (15 m dept/90 hours) Hazardous classification II 2 GD according to ATEX 94/9/EEC IP 68 according to EN60529 (15 m dept/90 hours)

Safety Compliance
Electromagnetic compatibility directive (EMC) EFS2000 actuators conform to the requirements of EMC Directive 2004/108/EC and further amendments.

!@#$ flow control

20

Low voltage directive (LV) EFS2000 actuators conform with Low Voltage Directive 2006/95/EC and further amendments by the application of EN60204-1 1993. Machinery directive EFS2000 actuators comply with the provision of Machinery Directive 2006/42/EC.

Functional Safety (IEC 61508)

Suitable for use in SIL 3 application; TUV certificate

..

Test Summary
Life test Standard ICON2000 life test is based on AWWA 540-93 for a minimum of 10,000 cycles. Vibration test EFS2000 are certified as per IEC 60068-2-6- Appendix B (plant induced): frequencies from 1 to 500 Hz (in 3 axes) with 2.0g peak acceleration. Sweep cycles in each axis: 10. Seismic test EFS2000 are tested in accordance with IEC 60068-2-57. Frequencies from 1 to 35 Hz (in 3 axes) with max 2.0g peak acceleration. Verification of structural integrity at 5g. Endurance of oscillogram: 30 seconds.

Motors
Base version ICON2000 are equipped with three-phase asynchronous, squirrel cage, induction-type low-inertia balanced motors. For single phase or direct current supply, a special interface allows to use conventional asynchronous motors. The open frame is protected by an Explosionproof / Waterproof cover fixed on the actuator housing. Internal protection by a temperature sensor, inserted in the motor windings. The motor flange is directly coupled to the actuator housing with internal flying leads wired to an intermediate terminal board. Electric motors are supplied with insulation class for H as standard with dedicated speed and temperature sensor.

!@#$ flow control

21

Manual override
All actuators may be provided with an hydraulic control group for manual operation by means of a hand-pump in case of power failure. This control group is also necessary to adjust the fail-safe speed.

Terminal block
Terminal block is located in a double sealed enclosure. The terminal block is provided with the following terminations and accessories: - 3 terminals for power supply - 46 terminals for controls - 2 for DC external supply - 2 for low voltage (max 230V) external supply - 1 external earth - 1 external neutral

Cable entries
Three cable entries are supplied as standard. One extra entry is optionally available. The standard thread is NPT and diameter is: - one with 11/2" - two with 1" - one with 3/4" (optional) ISO Rc 7/1, ISO metric BS3643 and DIN 40430/PG and different diameters are available as options.

Data logger
Data logger is available for collecting different types of data useful in maintenance or diagnostic programs. Since the amount of collected data is quite large, the data logger must be downloaded onto a Pc/Pda through Irda or BluetoothTM connection to be viewed. The main functions of the Data logger are: - RECORDER mode: measurement and memorisation of main voltage supply (V), motor temperature (C), electronics compartment temperature (C), with configurable sampling time and start date and time (up to 256 sets of measures can be memorised) - EVENT mode: memorisation of Open or Close commands, with indication of source, date and time. Configurable Start date and time. Up to 128 events can be memorised. - T-RECORDER mode: measurement and memorization of torque in opening (%), torque in closing (%), motor temperature (C), electronic compartment temperature (C) with configurable sampling time, start and time. The last 256 measures are continuously memorised. When a torque alarm arises the T-recorder stops.

!@#$ flow control

22

!@#$ flow control

23

A large variety of optional modules can be added to the base version. If the option you are looking for is not listed below, please contact Biffi.

Fieldbus interfaces
ICON2000 modular design is easily upgraded from base-to-base to bus versions. You just need to add the relevant plug-in card. ICON2000 flexible interface allows connection to the major field bus available on the market: Foundation Fieldbus Profibus DPV0, DPV1 and redundant DPV1 LonWorks Hart Modbus Please ask our Sales people for specific requirements.

Position Servoamplifier Module (PSM)


The module is necessary for actuators in modulating and inching duty. It drives the motor through pulses at constant frequency and duration proportional to the position error, following an externally set analogical point signal. The basic features are: Input: 4-20 mA or 0-20 mA with galvanic insulation Output: 4-20 mA with galvanic insulation for position or torque re-transmission. Three additional SPST output contacts to be configured "make or break". 2 interlock inputs.

Position Analogue Retransmission Module (APTM)


This card gives a 4-20 mA galvanically insulated module for position or torque retransmission. It is easily plugged in on the base card with no need for dedicated tools.

Solid state power switch over temperature


(only for heavy modulation duty version) It detects power card maximum temperature condition and sets the relevant alarm.

Extended temperature ranges


-40/+70 C by use of extended range components -55/+70 C by use of a heating source for internal electronic components, powered by external supply.

!@#$ flow control

24

Partial stroke test (PST)


Through a specific procedure a partial stroke test function can be carried out to check the functionality of the essential parts to achieve the EFS safety function while the valve/actuator is in line and in service.

Anticondensate heater
The internal modules provide enough power to grant anticondensation protection for general applications. But when the environment air humidity reaches critical levels, an additional heater (10 Watt - 1500 Ohm, with external power supply) may be supplied on request.

Battery
Auxiliary batteries can be provided in an intrinsically safe enclosure. With auxiliary batteries it is possible to remotely transmit position also in case of power failure.

!@#$ flow control

25

Spring to Open

The information herein contained is reserved property of Biffi and is subject to being modified without notice.

Standard cable entries: a = 1 NPT b = 1 1/2 NPT

EFS2000 Series Overall Dimensions


Model EFS 10 OP EFS 20 OP EFS 40 OP EFS 80 OP EFS 160 OP EFS 320 OP EFS 480 OP EFS 960 OP
!@#$ flow control

A 780 780 1020 1020 1390 2055 2055 3025

a1 374 374 540 540 780 1070 1070 1925

a2 406 406 480 480 610 985 985 1100

B 575 575 575 575 575 582 582 624

b1 273 273 273 273 273 283 283 313

b2 302 302 302 302 302 299 299 311

b3 36 36 65 65 125 164 164 204

H 475 475 475 475 525 700 700 800

Weight (Kg) 100 120 160 180 300 515 550 880

26

Spring to Close

Standard cable entries: a = 1 NPT b = 1 1/2 NPT

EFS2000 Series Overall Dimensions


Model EFS 10 CL EFS 20 CL EFS 40 CL EFS 80 CL EFS 160 CL EFS 320 CL EFS 480 CL EFS 960 CL A 780 780 1020 1020 1390 2055 2055 3025 a1 374 374 540 540 780 1070 1070 1925 a2 406 406 480 480 610 985 985 1100 B 575 575 575 575 575 582 582 624 b1 273 273 273 273 273 283 283 313 b2 302 302 302 302 302 299 299 311 b3 36 36 65 65 125 164 164 204 H 475 475 475 475 525 700 700 800 Weight (Kg) 100 120 160 180 300 515 550 880
!@#$ flow control

27

EFS2000 Series WGR


d7 Max Stem Acceptance
Insert Bush

Model EFS10 EFS20 EFS40 EFS80 EFS160 EFS320 EFS480 EFS960

ISO 5211 F10 F10 F14 F14 F16 F25 F25 F30

d1 125 125 175 175 210 300 300 350

d3 102 102 140 140 165 254 254 298

d4 M10 M10 M16 M16 M20 M16 M16 M20

N 4 4 4 4 4 8 8 8

Hmin 50 50 89 89 105 130 130 165

h1 20 20 25 25 30 25 25 30

d7 25 25 42 42 65 90 90 103

dx 35 35 51 51 76 104 104 120

!@#$ flow control

28

Torque Curves
Fail to Open diagram

Fail to Close diagram

Note: Please refer to the torque performance tables in the following pages.

!@#$ flow control

29

EFS2000 v4 - 3Ph version - Spring to Open data sheet


EFS Model EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS 10OP/93-46 10OP/93-31 10OP/93-15 10OP/93-10 10OP/93-5 20OP/225-46 20OP/225-31 20OP/225-15 20OP/225-10 20OP/225-5 40OP/450-92 40OP/450-61 40OP/450-31 40OP/450-20 40OP/450-10 80OP/900-92 80OP/900-61 80OP/900-31 80OP/900-20 80OP/900-10 160OP/1800-146 160OP/1800-97 160OP/1800-73 160OP/1800-49 160OP/1800-24 320OP/3600-230 (2) 320OP/3600-153 (2) 320OP/3600-77 320OP/3600-51 320OP/3600-26 480OP/4500-115 480OP/4500-77 480OP/4500-51 480OP/4500-26 960OP/9000-202 (*) 960OP/9000-101 (*) 960OP/9000-34 (*) SET
[Nm]

SST
[Nm]

MST
[Nm]

MET
[Nm]

ET
[Sec]

93 93 93 93 93 225 225 225 225 225 450 450 450 450 450 850 850 850 850 850 1800 1800 1800 1800 1800 3600 3600 3600 3600 3600 4500 4500 4500 4500 9000 9000 9000

130 130 130 130 130 300 300 300 300 300 610 610 610 610 610 1150 1150 1150 1150 1150 2800 2800 2800 2800 2800 5400 5400 5400 5400 5400 7800 7800 7800 7800 12000 12000 12000

150 150 150 150 150 350 350 350 350 350 680 680 680 680 680 1250 1250 1250 1250 1250 2800 2800 2800 2800 2800 5400 5400 5400 5400 5400 5800 5800 5800 5800 12000 12000 12000

110 110 110 110 110 275 275 275 275 275 520 520 520 520 520 900 900 900 900 900 1800 1800 1800 1800 1800 3600 3600 3600 3600 3600 3600 3600 3600 3600 8200 8200 8200

46 31 15 10 5 46 31 15 10 5 92 61 31 20 10 92 61 31 20 10 146 97 73 49 24 230 153 77 51 26 115 77 51 26 202 101 34

MAX SET ACTUATOR OUTPUT TORQUE [Nm] (1) 260 240 350 350 350 660 590 520 520 520 1.260 1.130 1.010 1.010 1.010 1.800 1.700 2.000 1.900 1.900 3.900 3.900 4.500 4.400 4.400 7.500 7.500 8.600 8.600 8.400 11.800 11.000 11.000 10.800 17.400 19.200 19.200

FST
From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs

ICON Model ICON-010/25-8 ICON-010/25-12 ICON-010/25-25 ICON-010/25-37 ICON-010/25-74 ICON-010/50-8 ICON-010/50-12 ICON-010/50-25 ICON-010/50-37 ICON-010/50-74 ICON-010/60-8 ICON-010/60-12 ICON-010/60-25 ICON-010/60-37 ICON-010/60-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-020/210-8 ICON-020/210-12 ICON-020/210-25 ICON-020/210-37 ICON-020/210-74 ICON-020/240-16 ICON-020/240-25 ICON-020/240-37 ICON-020/240-74 (*) (*) (*)

Legenda SET SST MST MET ET FST (*) (1) Spring ending torque (Nm) at 90 (end to open) Spring starting torque (Nm) at 0 (start to open) Electric Mode starting torque (Nm) at 90 (start to close) Electric Mode ending torque (Nm) al 0 (end to close) Time for stroke (sec/90) with electric motor at 50Hz; multiply by 0,833 for 60Hz supply Fail safe adjustable time (sec/90) For model EFS960 please contact BIFFI. The Max Set Actuator Output torque is referred to the Open manoeuvre done with the electric motor set @ 40% and the spring. FOR NO REASON, THE MOTOR SET TORQUE OF 40% IN THE OPENING DIRECTION HAS TO BE CHANGED AND TORQUE BY-PASS BE REMOVED. Motor service limited to S2-10'.

(2)

EFS performance table above is referred only to actuators ON/OFF service, up to 60 starts/hour, motor service S2-15'.

!@#$ flow control

30

EFS2000 v4 - 3Ph version - Spring to Close data sheet


EFS Model EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS EFS 10CL/93-46 10CL/93-31 10CL/93-15 10CL/93-10 10CL/93-5 20CL/225-46 20CL/225-31 20CL/225-15 20CL/225-10 20CL/225-5 40CL/450-92 40CL/450-61 40CL/450-31 40CL/450-20 40CL/450-10 80CL/900-92 80CL/900-61 80CL/900-31 80CL/900-20 80CL/900-10 160CL/1800-146 160CL/1800-97 160CL/1800-73 160CL/1800-49 160CL/1800-24 320CL/3600-230 320CL/3600-153 320CL/3600-77 320CL/3600-51 320CL/3600-26 480CL/4500-115 480CL/4500-77 480CL/4500-51 480CL/4500-26 960CL/9000-202 (*) 960CL/9000-101 (*) 960CL/9000-34 (*) SET
[Nm]

SST
[Nm]

MST
[Nm]

MET
[Nm]

ET
[Sec]

93 93 93 93 93 225 225 225 225 225 450 450 450 450 450 850 850 850 850 850 1800 1800 1800 1800 1800 3600 3600 3600 3600 3600 4500 4500 4500 4500 9000 9000 9000

130 130 130 130 130 300 300 300 300 300 610 610 610 610 610 1150 1150 1150 1150 1150 2800 2800 2800 2800 2800 5400 5400 5400 5400 5400 7800 7800 7800 7800 12000 12000 12000

150 150 150 150 150 350 350 350 350 350 680 680 680 680 680 1250 1250 1250 1250 1250 2800 2800 2800 2800 2800 5400 5400 5400 5400 5400 5800 5800 5800 5800 12000 12000 12000

110 110 110 110 110 275 275 275 275 275 520 520 520 520 520 900 900 900 900 900 1800 1800 1800 1800 1800 3600 3600 3600 3600 3600 3600 3600 3600 3600 8200 8200 8200

46 31 15 10 5 46 31 15 10 5 92 61 31 20 10 92 61 31 20 10 146 97 73 49 24 230 153 77 51 26 115 77 51 26 202 101 34

MAX SET ACTUATOR OUTPUT TORQUE [Nm] (1) 260 240 350 350 350 660 590 520 520 520 1.260 1.130 1.010 1.010 1.010 1.800 1.700 2.000 1.900 1.900 3.900 3.900 4.500 4.400 4.400 7.500 7.500 8.600 8.600 8.400 11.800 11.000 11.000 10.800 17.400 19.200 19.200

FST
From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 2 to 20 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 3 to 30 secs From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs

ICON Model ICON-010/25-8 ICON-010/25-12 ICON-010/25-25 ICON-010/25-37 ICON-010/25-74 ICON-010/50-8 ICON-010/50-12 ICON-010/50-25 ICON-010/50-37 ICON-010/50-74 ICON-010/60-8 ICON-010/60-12 ICON-010/60-25 ICON-010/60-37 ICON-010/60-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-020/210-8 ICON-020/210-12 ICON-020/210-25 ICON-020/210-37 ICON-020/210-74 ICON-020/240-16 ICON-020/240-25 ICON-020/240-37 ICON-020/240-74 (*) (*) (*)

Legenda SET SST MST MET ET FST (*) (1) Spring ending torque (Nm) at 0 (end to close) Spring starting torque (Nm) at 90 (start to close) Electric Mode starting torque (Nm) at 0 (start to open) Electric Mode ending torque (Nm) al 90 (end to open) Time for stroke (sec/90) with electric motor at 50Hz; multiply by 0,833 for 60Hz supply Fail safe adjustable time (sec/90) For model EFS960 please contact BIFFI. The Max Set Actuator Output torque is referred to the Close manoeuvre done with the electric motor set @ 40% and the spring. FOR NO REASON, THE MOTOR SET TORQUE OF 40% IN THE CLOSING DIRECTION HAS TO BE CHANGED AND TORQUE BY-PASS BE REMOVED. Motor service limited to S2-10'.

(2)

EFS performance table above is referred only to actuators ON/OFF service, up to 60 starts/hour, motor service S2-15'.

!@#$ flow control

31

General Configuration

!@#$ flow control

32

NOTES

!@#$ flow control

33

NOTES

!@#$ flow control

34

For any further information you may require please contact Biffi Sales office; tel. ++39-0523.944411, fax ++39-0523.943923, e-mail: [email protected]

!@#$ flow control

Biffi reserves the right to modify contents without notice.

35

EF S2 00 0BU -E

Biffi Italia s.r.l.


Headquarters, Sales department, 29017 Fiorenzuola dArda - Italy tel. +39 0523 944411 fax +39 0523 943923 e-mail [email protected] website: www.biffi.it